• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 1
  • Tagged with
  • 31
  • 12
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Klimatanpassningsplan och kostnads-nyttoanalys för Tullkammarkajen och Söder : Inriktning högre temperaturer, ökad nederbörd och stigande havsnivåer

Sörman, Petra January 2016 (has links)
”Mark som är eller kan bli olämplig, avseende de boendes hälsa och säkerhet eller om risken föröversvämning, erosion och olyckor är stor, ska ingen bebyggelse planeras eller uppföras. Enmedveten planering för en framtida klimatförändring utvecklar stadens anpassningsförmåga, gör den mindre sårbar och gör att man kan skapa ett mer robust samhälle” (Halmstads översiktsplan 2030) Som klimatet nu förändras, kommer Halmstad inom en snar framtid att få räkna med temperaturhöjningar, ökad nederbörd och stigande havsnivåer. För en stor och kustnära kommun som Halmstad krävs det att kommunen anpassar sig inför dessa utmaningar och vidtar nödvändiga åtgärder i god tid. Konsekvenserna kan bli stora om anpassning inte sker för ett förändrat framtida klimat. Halmstad kommun har två områden i staden som kräver vidare analys, dessa är Tullkammarkajen och Söder. Tullkammarkajen är ett planerat bostadsområde som ska börja bebyggas 2020 och området Söder är till stor del redan bebyggt. Båda områdena är belägna direkt intill Nissan, som översvämmas vid vattenstånd på cirka +2,0 m ö h. Idag kan staden räkna med extremnivåer på +2,5 m ö h och vid stormen Gorm (2015) rådde ett vattenstånd på +2,37 m ö h. Prognoser från bl.a. SMHI tyder på att havsnivån kommer öka en meter fram till år 2100. Samtidigt minskar återkomsttiderna för vattenstånd på +2,5 m öh från cirka 50 år till endast 2 år fram till år 2100. Medeltemperaturen i Halmstad kommer öka under detta århundrade från 6-8°C till 10-14°C. Antalet varma dagar ökar från 10-15 till 50-55 dagar per år och värmeböljorna under sommaren kommer bli mycket längre, med torka, vattenbrist och i värsta fall dödsfall till följd. Syftet med rapporten har varit att ta fram åtgärdsalternativ för att minska risken för översvämningar och värmeböljor i staden. Samhällets resurser är begränsade, vilket medför att det behövs en så kostnadseffektiv anpassning som är möjligt. Kommunen har idag liten kunskap om de mest lönsammaste alternativen för att minska påverkan från översvämningar och värmeböljor, varför rapporten utreder den frågan. Metod har varit en översvämningssimulering, 14 intervjuer, en litteraturstudie och en samhällsekonomisk bedömning genom en kostnads-nyttoanalys. Fyra olika åtgärdsalternativ, som minskar risken för översvämningar och värmeböljor, redovisas i rapporten och utreder om översvämningsåtgärderna är samhällsekonomiskt lönsamma. Åtgärderna innebär bland annat ökad vegetation, höjdsättning, backventiler, vallar, slussport och pumpar. I den samhällsekonomiska bedömningen jämförs nyttan från åtgärderna med kostnader. Analysen visar att trots höga investeringskostnader är samtliga åtgärdsalternativ samhällsekonomiskt lönsamma meden tidshorisont på 100 år fram i tiden. / "Land that is or may be inappropriate, regarding the residents' health and safety or the risk of flooding, erosion and accidents is great, no settlement should be planned or built. An increased awareness in planning for a future climate change develops the city's adaptability, making it less vulnerable and allows it to become a more robust society" (Halmstads översiktsplan 2030). Considering how the world and local society is developing, Halmstad will in the near future experience temperature rise, increased rainfall and rising sea levels. For a large coastal municipality like Halmstad, it is required that the municipality adapt to these challenges and take the necessary measures in good time. The consequences can be devastating if adaptation is not done for a changed future climate. Halmstad has two areas in the city that require further analysis, these are Tullkammarkajen and Söder. Tullkammarkajen is a planned residential area, that will be built in 2020 and Söder is an area that is largely already built. Both areas are located directly next to Nissan, which floods when the water level rises above approximately +2.0 meter above sea level(masl). Today the city can count on extreme levels of +2.5 masl and the autumnstorm Gorm (2015) advised a water level of +2.37 masl. Forecasts from SMHI indicate that the sea level will increase one meter by 2100. At the same time the recurrence times for the water level of +2.5 masl will be reduced from about 50 years to only 2 years until year 2100. The temperature in Sweden will increase during this century and Halmstads average temperature will increase from 6-8°C to 10-14°C. The number of hot days increases from 10-15 to 50-55 days per year and heat waves during the summer will be much longer, with droughts, shortage of water and in worst case deaths as a result. The purpose of the report was to develop policy options for reducing the risk of floods and heat waves in Halmstad. The resources in the society are limited, therefore the most cost-effective adaptation is needed. The municipality currently has no knowledge of the most profitable options for reducing the impact of floods and heat waves, hence this report aims to investigate the matter. Method has been a flood simulation, 14 interviews, a literature review and an economic assessment by a cost-benefit analysis. Four different policy options, which reduce the risk of flooding and heatwaves, are listed in the report and investigate if the flood measures is economically profitable. They include increased vegetation,elevation, check valve, dykes, sluice gate and pumps. The assessment compares the benefits from the actions with the cost in an economic assessment. The analysis shows that despite high investment costs, all proposals for action are economically viable with a time horizon of 100 years.
2

Den skötselextensiva trädgården : Åtgärdsförslag för en lättskött trädgård i samband med en nybyggd villa

Arola, Helena January 2011 (has links)
I samband med ett bygge av en privatvilla ställs man inför många val. Det är inte ovanligt att trädgården hamnar i skymundan i förhållande till alla interiöra beslut som ska fattas. Min utgångspunkt i den här uppsatsen är att det finns en efterfrågan på lättskötta trädgårdar bland ägare till nybyggda villor i Gävle. Genom intervjuer med tio familjer som nyligen ”blivit med trädgård” och genom intervjuer med människor med erfarenhet i byggbranschen har jag tagit fram åtgärdsförslag för den skötselextensiva trädgården.
3

Energianalys av ett flerbostadshus med kombinerad fjärrvärme och frånluftsvärmepump : Åtgärdsförslag på energi- och kostnadsbesparingar för fastigheten Sicklaön 173:1, Stockholm

Klang, Kristoffer January 2015 (has links)
Syftet med denna studie är att öka den energitekniska förståelsen för en byggnad med kombinerad fjärrvärme och frånluftsvärmepump, i hänseende till ålder, storlek, klimatskal och tekniska installationer, samt öka kunskapen om energieffektivisering och dess kostnad för inblandade parter. Studien har gjorts genom energianalys av fastigheten för att kartlägga energianvändningen och därigenom kunna ge åtgärdsförslag på energieffektiva lösningar på befintliga system. Energianalysen visar att nio möjliga åtgärder, där en reducering av inomhustemperaturen och byte till snålspolande munstycken är tongivande, kan genomföras med en total energibesparing på 170 MWh/år och en total kostnadsbesparing på 295 kkr/år, vilket motsvarar en minskning av energin med cirka 11 % och en minskning av kostnaden med cirka 24 %. Anledningen till att reduceringen av kostnaden kan bli så mycket större än reduceringen av energianvändningen beror på att det går att byta nuvarande munstycken till mer snålspolande. Detta medför en minskning av energianvändningen med endast 27 MWh/år då den största reduceringen är av tappkallvatten, men den ekonomiska besparingen blir 157 kkr/år på grund av den minskade vattenförbrukningen. Dessutom går det att säkra ned elabonnemangen, vilket inte ger ett reducerat elbehov, utan endast en lägre fast avgift. Utöver energianalysen har en jämförelse mellan frånluftsvärmepump och fjärrvärme gjorts. Där har dessa ställts emot varandra med motiv på energibehov, kostnader och dess påverkan på miljön. Resultatet av detta visar att en jämförelse borde tas med i beräkningen vid en eventuell nyinstallation då alternativet med fjärrvärme bland annat får en lägre kostnad per år med ca 59 kkr.
4

Energieffektivisering av Valhalla : Åtgärdsförslag för minskad energianvändning med hänsyn till en byggnads kulturvärde

Eriksson, Olle January 2014 (has links)
No description available.
5

Energiutredning på Chips AB, Åland / Energy Analysis at Chips AB, Åland

Renström, Thom, Sundbäck, Henrik January 2013 (has links)
En energikartläggning har gjorts hos Chips AB för att undersöka hur energin fördelas över de olika produktionslinjerna. Energianvändningen från processer som är gemensamma för alla produktionslinjer har också undersökts. Energianvändningen för dessa har fördelats över pro- duktionslinjerna eftersom produkterna även ska bära upp dessa energikostnader. Där det vi- sade sig att chipslinjen använder överlägset mest energi under ett år, 13 200 MWh, men den linjen körs mest också. Näst störst energianvändning hade moslinjen som bara låg på 6 600 MWh. När energianvändningen beräknades per producerat kilogram visade det sig att det var moslinjen som använder mest energi, 2,75 kWh/kg. Från energianvändningen beräknades kostnad och koldioxidutsläpp, både totalt och per pro- ducerat kilogram. Här visade det sig att moslinjen även har högst koldioxidutsläpp och högst kostnad per producerat kilogram. Chipslinjen har näst högst koldioxidutsläpp per producerat kilogram, men det är de friterade produkterna från PF2-linjen som har näst högst kostnad per producerat kilogram. Det beror på att det är olja som används till fritösen i PF2-linjen. Flera åtgärdsförslag för att minska energianvändningen har tagits fram. Det var två skorstenar som hade mycket överskottsvärme som kan användas, chipsfritösen och PF1-fritösen. De bästa förslagen skulle vara att använda denna överskottsvärme till uppvärmning av lokaler och tappvarmvatten samt uppvärmning av blanchörvatten. Tillsammans skulle detta i bästa fall kunna ge en årsbesparing på ungefär 516 000 € och ändå ha en återbetalningstid under ett år. Andra åtgärdsförslag som också undersöktes var förvärmning av luften till chipspannan, absorptionskyla och elproduktion, men dessa förslag hade mindre besparingspotential och längre återbetalningstid än det första förslagen. / An energy analysis has been made at Chips AB to investigate how the energy is distributed over the various production lines. Energy from processes common to all production lines have also been investigated. Energy use for these have been distributed over the production lines since the products also should carry these energy costs. There, it is shown that the potato chips line is using by far the most energy in a year, 13,200 MWh, but it is the line that runs the most too. The potato mash line had the second largest energy use, at 6,600 MWh. But when the energy usage was calculated per kilogram produced, it turned out that it was the potato mash line that use the most energy, 2.75 kWh/kg. From the total energy use the cost and carbon emissions were calculated, both in total and per produced kilogram. Here it showed that the potato mash line also has the highest emissions of carbon dioxide and the highest energy cost per kilogram produced. It is also the potato chips line that has the second highest emissions of carbon dioxide per kilogram produced, but it is the fried products from the PF2 line that has the second highest energy cost per kilogram pro- duced. This is because the fryer in the PF2 line uses oil to heat up the frying oil. Several proposed measures to reduce energy use have been developed. Three of the chimneys that were measured at Chips AB had a lot of excess heat that can be used, it was the potato chips fryer, the PF1 boiler and the PF1 fryer. The best proposed measures is to use the excess heat for space heating and domestic hot water and to heat the blanching water. Together, these measures could at best be able to provide an annual saving of approximately € 516,000, and still have a payback period of less than a year. Other proposed measures that also were inves- tigated were preheating of the air to the potato chips boiler, absorption cooling and power generation, but these proposals had less savings and longer payback periods than the first pro- posals.
6

Energibesparing åt Klövern AB : Förslag på åtgärder för minskad driftkostnad för Klövern AB’s fastigheter / Energy saving för Klövern AB : Proposed measures to reduce operating costs

Eriksson, Per, Trygg-Svensson, Sebastian, Österbring, Magnus January 2010 (has links)
Fastighetsbolaget Klövern AB förvaltar 45 fastigheter i Karlstad kommun. Med stigande energipriser ökar behovet för Klövern att energieffektivisera sina fastigheter för att minska kostnaderna. Rapportens syfte är att undersöka tre av Klövern utvalda fastigheter med hög energiförbrukning. Målet är att presentera energibesparande åtgärder för Klövern att använda som beslutsunderlag för framtida investeringar. För åtgärdsförslagen görs LCC-analyser för att undersöka om de är lönsamma. Därefter görs känslighetsanalys för de mest lönsamma alternativen för att tydliggöra osäkerheten i beräkningsunderlaget. De åtgärder som rekommenderas har ett positivt nuvärde efter livslängd, rangordning av dessa alternativ görs sedan efter avkastning. De tre fastigheterna är Gripen 11, Blåsten 4, Styrmannen 5.   För Gripen 11 undersöktes möjligheterna att installera solfångare, åtgärda ventilationssystem och att tilläggsisolera vissa delar av fastigheten. Resultatet visar att de bästa energibesparingsåtgärderna är att öka temperaturverkningsgraden för värmeväxlare i system 1 vilket ger en besparing på ca 135000 kWh/år samt att optimera drifttiden för system 2 vilket ger en besparing på ca 17000 kWh/år. Installation av 110 kvm solfångare ger en årlig energibesparing på ca 48000 kWh/år.   Blåsten 4 består av en huvudbyggnad med fyra ventilationssystem samt en lagerlokal med luftvärmepumpar. För fastigheten undersöktes effekten av att ersätta ventilationssystem 2, 3 och 4 med ett nytt gemensamt ventilationssystem med värmeväxlare. Undersökningar har gjorts för hur lönsamheten ser ut för att byta uppvärmningssystem från, i dagsläget, direktverkande el. Nya system som undersöktes är bergvärme, fjärrvärme, en kombination av dessa samt luft/vatten-värmepump. Vid byte av uppvärmningssystem inkluderas installation av radiatorsystem. Analys av lönsamhet för tilläggsisolering, solceller och solfångare har genomförts. Resultatet visar att åtgärda ventilationssystemen enligt ovan ger en energibesparing på ca 235000 kWh/år. Att byta uppvärmningssystem till fjärrvärme ökar energikonsumtionen med ca 70000 kWh/år men ger en besparing på ca 130000 kr/år då fjärrvärme är ett billigare alternativ än direktverkande el (kr/kWh). Installation av solfångare med bidrag från Boverket är lönsamt och ger en energibesparing på ca 8800 kWh/år.   Styrmannen 5 består av två byggnader med kontorsverksamhet. Fastigheterna är fristående men binds ihop av ett garage under marken som värms upp till 12 grader. Tre ventilationssystem med värmeväxling finns i byggnaderna samt frånluftssystem. Liknande förutsättningar gäller för båda fastigheterna, stora delar av fasaderna består av fönster och FTX-systemen har relativt hög verkningsgrad. Mellan husen finns en park som i dagsläget är uppvärmt med markvärme under vinterhalvåret för att hålla den snöfri. De åtgärdsförslag som undersökts för att minska energianvändningen är dels att installera ventilationssystem med högre verkningsgrad än vad som idag finns, bygga om ett ventilationssystem för att värma garaget med frånluft, helt stänga av uppvärmningen av garaget samt att snöröja parken manuellt istället för med markvärme. Resultatet visar att installation av nya ventilationssystem inte klarar lönsamhetskraven, åtgärder medför en energibesparing för hus A på ca 24000 kWh/år och för hus B ca 15500kWh/år. Däremot klarar ombyggnationen av ventilationssystemet för att värma garaget lönsamhetskravet och sparar ca 140000 kWh/år. Då åtgärderna att snöröja istället för markvärme samt att helt stänga av uppvärmningen av garaget inte har någon investeringskostnad kan avkastning inte beräknas, dessa åtgärder skulle dock spara ca 180000 kWh/år respektive ca 95000 kWh/år. / The real estate company Klövern LTD manages 45 properties in Karlstad. With rising energy prices the necessity to be more energy efficient in their properties to reduce costs, increases. The reports purpose is to examine three of Klöverns worst properties concerning high energy consumption. The goal is to introduce energy saving measures to Klövern which will be used as a basis for future investments. LCC-analyses are made to examine whether or not different modifications and installations are profitable. Sensitivity analysis is done for the most viable options to clarify the uncertainty in the calculations e.g. investment cost, inflation. The recommended actions have a positive LCC-value under their life-span, the ranking of these alternatives are then made after how much they yield under their life-span. The three properties that are examined are Gripen 11, Blåsten 4, Styrmannen 5. For Gripen 11 surveys where made for the possibility of installing solar panels, installation of  new heat exchangers to some of the ventilation system and to put in additional insulation in certain parts of the property. Results show that the best energy saving measures is to increase the temperature efficiency of heat exchangers in system one which gives a saving of approximately 135 000 kWh/year, and to optimize the operating time of system two resulting in a saving of approximately 17 000 kWh/year. Installation of 110 square meters of solar collectors provide an annual energy saving of approximately 48 000 kWh/year. Blåsten 4 consists of a main building with four ventilation systems and a warehouse with heat pumps. For this property, studies where made as to the effect of replacing three ventilation systems (2, 3 and 4) with one new ventilation system with a heat exchanger. Studies have been undertaken for the profitability of changing the heating system from, the current situation, heating by electricity. New heating systems that were investigated where geothermal heating, district heating, a combination thereof, and air/water heat pump. The replacing of the heating system includes an installation of radiator systems. Analyses of the profitability of solar cells and solar panels have also been made. The results show that to modify the ventilation systems, as described above, provides an energy saving of approximately 235 000 kWh/year. Replacing the heating system with district heating will increase the energy consumption by about 70 000 kWh/year, but will give a saving of approximately 130 000 SEK/year because district heating is a cheaper alternative than heating with electricity (SEK/kWh). Installation of solar panels, with grants from Boverket, is profitable and provides an energy saving of about 8800 kWh/year. Styrmannen 5 consists of two office buildings. The buildings are independent but bound together by an underground garage which is heated to 12 degrees. Three ventilation systems with heat exchange and one exhaust system without exists in the buildings. Similar conditions apply to both buildings, large parts of the facades are made up of windows and the heat exchangers in the ventilation systems have a rather high efficiency. Between the houses there is a park which is heated by ground heat in the winter to keep it free from snow. Studies were made to examine the effects of installing a new heat exchange system with high efficiency to reduce energy use, rebuild one of the ventilation systems in order to use the exhaust air to heat the garage, al together turn off the heating of the garage and to remove the snow manually instead of using ground heat. The results show that installing a new heat exchange systems will not be profitable. Rebuilding one of the ventilation systems to heat the garage is profitable and saves approximately 140 000 kWh/year. The measures to manually remove snow in the winter instead of ground heat, and turning of the heating of the garage would save about 180 000 kWh/year respectively approximately 95 000 kWh/year.
7

Skapandet av rekommendationer i en olycksutredning : Sju haveriutredares tankar om rekommendationers utformning

Götmar, Anna January 2007 (has links)
<p>I samhället finns många verksamheter där avancerad teknik och människor skapar komplexa system som förväntas fungera på ett säkert sätt. Som en del av det arbete mot förbättrad säkerhet som ständigt pågår i dessa system kan olyckor som inträffat bli föremål för en utredning. Statens Haverikommission har som uppgift att utreda olyckor inom bland annat transportdomänerna med avsikten att klarlägga händelseförlopp och orsak till en händelse samt att beskriva resultaten i en rapport. Som ett medel för att förbättra säkerheten kan rekommendationer lämnas till respektive tillsyns- eller säkerhetsmyndighet med avsikten att fungera som underlag för beslut om lämpliga åtgärder för att om möjligt förhindra att en liknande olycka ska inträffa i framtiden.</p><p>Det är viktigt att en olycksutredning sker på ett rationellt och systematiskt sätt så att olycksredovisningen inte snedvrids av förutfattade meningar eller favorithypoteser. Teorier gör gällande att utredare har egna olycksmodeller, d.v.s. sätt att se på olyckor och deras uppkomst. Denna olycksmodell stöder utredaren och påverkar olika beslut som fattas under utredningens gång.</p><p>Studien som ligger till grund för denna uppsats har undersökt hur utredare på Statens Haverikommission skapar sig en uppfattning om vilka åtgärder som bäst förebygger olyckor i en verksamhet utifrån resultaten av en utredning. Ett särskilt fokus lades på frågan hur utredare bedömer en rekommendations förmodade effektivitet.</p><p>Metoden som användes under studien bestod av litteraturstudier samt sju semistrukturerade intervjuer. Intervjuerna analyserades kvalitativt och resultaten jämfördes sedan med teorier ur tidigare forskning.</p><p>Under studien identifierades ett antal kriterier som utredarna ansåg kunde öka rekommendationens möjlighet att få en säkerhetshöjande effekt om de uppfylldes. Huvudsakligen utgjordes dessa av att kostnaden bör vara i rimlighet med säkerhetsvinsten, rekommendationen bör peka på ett problem som tillsynsmyndigheten sedan får lösa, vara systempåverkande, motiveras så att mottagaren förstår och accepterar problemet, vara anpassad efter mottagarens säkerhetsmognad, vara tillräckligt generell för att fånga upp liknande olyckor och tillräckligt specifik för att mottagaren ska förstå problemet, ej skapa sidoeffekter, vara möjlig att avgöra om den är implementerad, vara välformulerad och begriplig.</p>
8

Energibesparing åt Klövern AB :  Förslag på åtgärder för minskad driftkostnad för Klövern AB’s fastigheter / Energy saving för Klövern AB : Proposed measures to reduce operating costs

Eriksson, Per, Trygg-Svensson, Sebastian, Österbring, Magnus January 2010 (has links)
<p>Fastighetsbolaget Klövern AB förvaltar 45 fastigheter i Karlstad kommun. Med stigande energipriser ökar behovet för Klövern att energieffektivisera sina fastigheter för att minska kostnaderna. Rapportens syfte är att undersöka tre av Klövern utvalda fastigheter med hög energiförbrukning. Målet är att presentera energibesparande åtgärder för Klövern att använda som beslutsunderlag för framtida investeringar. För åtgärdsförslagen görs LCC-analyser för att undersöka om de är lönsamma. Därefter görs känslighetsanalys för de mest lönsamma alternativen för att tydliggöra osäkerheten i beräkningsunderlaget. De åtgärder som rekommenderas har ett positivt nuvärde efter livslängd, rangordning av dessa alternativ görs sedan efter avkastning. De tre fastigheterna är Gripen 11, Blåsten 4, Styrmannen 5.</p><p> </p><p>För Gripen 11 undersöktes möjligheterna att installera solfångare, åtgärda ventilationssystem och att tilläggsisolera vissa delar av fastigheten. Resultatet visar att de bästa energibesparingsåtgärderna är att öka temperaturverkningsgraden för värmeväxlare i system 1 vilket ger en besparing på ca 135000 kWh/år samt att optimera drifttiden för system 2 vilket ger en besparing på ca 17000 kWh/år. Installation av 110 kvm solfångare ger en årlig energibesparing på ca 48000 kWh/år.</p><p> </p><p>Blåsten 4 består av en huvudbyggnad med fyra ventilationssystem samt en lagerlokal med luftvärmepumpar. För fastigheten undersöktes effekten av att ersätta ventilationssystem 2, 3 och 4 med ett nytt gemensamt ventilationssystem med värmeväxlare. Undersökningar har gjorts för hur lönsamheten ser ut för att byta uppvärmningssystem från, i dagsläget, direktverkande el. Nya system som undersöktes är bergvärme, fjärrvärme, en kombination av dessa samt luft/vatten-värmepump. Vid byte av uppvärmningssystem inkluderas installation av radiatorsystem. Analys av lönsamhet för tilläggsisolering, solceller och solfångare har genomförts. Resultatet visar att åtgärda ventilationssystemen enligt ovan ger en energibesparing på ca 235000 kWh/år. Att byta uppvärmningssystem till fjärrvärme ökar energikonsumtionen med ca 70000 kWh/år men ger en besparing på ca 130000 kr/år då fjärrvärme är ett billigare alternativ än direktverkande el (kr/kWh). Installation av solfångare med bidrag från Boverket är lönsamt och ger en energibesparing på ca 8800 kWh/år.</p><p> </p><p>Styrmannen 5 består av två byggnader med kontorsverksamhet. Fastigheterna är fristående men binds ihop av ett garage under marken som värms upp till 12 grader. Tre ventilationssystem med värmeväxling finns i byggnaderna samt frånluftssystem. Liknande förutsättningar gäller för båda fastigheterna, stora delar av fasaderna består av fönster och FTX-systemen har relativt hög verkningsgrad. Mellan husen finns en park som i dagsläget är uppvärmt med markvärme under vinterhalvåret för att hålla den snöfri. De åtgärdsförslag som undersökts för att minska energianvändningen är dels att installera ventilationssystem med högre verkningsgrad än vad som idag finns, bygga om ett ventilationssystem för att värma garaget med frånluft, helt stänga av uppvärmningen av garaget samt att snöröja parken manuellt istället för med markvärme. Resultatet visar att installation av nya ventilationssystem inte klarar lönsamhetskraven, åtgärder medför en energibesparing för hus A på ca 24000 kWh/år och för hus B ca 15500kWh/år. Däremot klarar ombyggnationen av ventilationssystemet för att värma garaget lönsamhetskravet och sparar ca 140000 kWh/år. Då åtgärderna att snöröja istället för markvärme samt att helt stänga av uppvärmningen av garaget inte har någon investeringskostnad kan avkastning inte beräknas, dessa åtgärder skulle dock spara ca 180000 kWh/år respektive ca 95000 kWh/år. </p> / <p>The real estate company Klövern LTD manages 45 properties in Karlstad. With rising energy prices the necessity to be more energy efficient in their properties to reduce costs, increases. The reports purpose is to examine three of Klöverns worst properties concerning high energy consumption. The goal is to introduce energy saving measures to Klövern which will be used as a basis for future investments. LCC-analyses are made to examine whether or not different modifications and installations are profitable. Sensitivity analysis is done for the most viable options to clarify the uncertainty in the calculations e.g. investment cost, inflation. The recommended actions have a positive LCC-value under their life-span, the ranking of these alternatives are then made after how much they yield under their life-span. The three properties that are examined are Gripen 11, Blåsten 4, Styrmannen 5. For Gripen 11 surveys where made for the possibility of installing solar panels, installation of  new heat exchangers to some of the ventilation system and to put in additional insulation in certain parts of the property. Results show that the best energy saving measures is to increase the temperature efficiency of heat exchangers in system one which gives a saving of approximately 135 000 kWh/year, and to optimize the operating time of system two resulting in a saving of approximately 17 000 kWh/year. Installation of 110 square meters of solar collectors provide an annual energy saving of approximately 48 000 kWh/year. Blåsten 4 consists of a main building with four ventilation systems and a warehouse with heat pumps. For this property, studies where made as to the effect of replacing three ventilation systems (2, 3 and 4) with one new ventilation system with a heat exchanger. Studies have been undertaken for the profitability of changing the heating system from, the current situation, heating by electricity. New heating systems that were investigated where geothermal heating, district heating, a combination thereof, and air/water heat pump. The replacing of the heating system includes an installation of radiator systems. Analyses of the profitability of solar cells and solar panels have also been made. The results show that to modify the ventilation systems, as described above, provides an energy saving of approximately 235 000 kWh/year. Replacing the heating system with district heating will increase the energy consumption by about 70 000 kWh/year, but will give a saving of approximately 130 000 SEK/year because district heating is a cheaper alternative than heating with electricity (SEK/kWh). Installation of solar panels, with grants from Boverket, is profitable and provides an energy saving of about 8800 kWh/year. Styrmannen 5 consists of two office buildings. The buildings are independent but bound together by an underground garage which is heated to 12 degrees. Three ventilation systems with heat exchange and one exhaust system without exists in the buildings. Similar conditions apply to both buildings, large parts of the facades are made up of windows and the heat exchangers in the ventilation systems have a rather high efficiency. Between the houses there is a park which is heated by ground heat in the winter to keep it free from snow. Studies were made to examine the effects of installing a new heat exchange system with high efficiency to reduce energy use, rebuild one of the ventilation systems in order to use the exhaust air to heat the garage, al together turn off the heating of the garage and to remove the snow manually instead of using ground heat. The results show that installing a new heat exchange systems will not be profitable. Rebuilding one of the ventilation systems to heat the garage is profitable and saves approximately 140 000 kWh/year. The measures to manually remove snow in the winter instead of ground heat, and turning of the heating of the garage would save about 180 000 kWh/year respectively approximately 95 000 kWh/year.</p>
9

Kommer Halland att bli nya Atlantis? : Förebyggande åtgärder vid översvämningar och havsnivåhöjning

Kling, Greta, Patriksson, Malin January 2020 (has links)
All municipalities in Halland are at risk of flooding caused by either rising sea level or extreme rainfall. Flooding causes damage to the physical environment and harmful health risks. Our aim is to analyze the possible effects of a rising sea level and floods as a result of extreme weather for Halland County. Furthermore, we will also identify and assess which actions the municiplatities are taken to prevent damages due to the rising of sea level or floods due to weather conditions. To obtain answers to our questions, a literature search was preformed. Interviews have been conducted with those responsible at the municipalities in Halland. Materials from municipalities and responsible authorities have also been studied. The results of the interviews shows a variation in the municipalities in the preventive work against flooding at the same time as there are some similarities. All municipalities are aware of the risks and have mapped which areas that are supposed to be affected. The conclusion of the present study was that more measures need to be taken, to make the municipalities more prepared. Suggested measures are the use of ecological edge zones, climate-proof buildings, underground tunnels that lead away water, green and blue areas, traditional revetment, revetment with plants, closable gates in rivers and beach nourishment.
10

Dagvattenhantering i urban miljö : Komplettering av befintliga avvattningssystem i Hemlingby

Assefa, Edom, Ngabonziza, Bertrand January 2016 (has links)
Denna studie syftar till att ta fram lösningsförslag som kan komplettera Hemlingbys befintliga avvattningssystem som består av VA-ledningar och dammar. Lösningsförslagen som presenteras i rapporten har tagits fram med hänsyn till nulägesanalysering samt bedömning av nollalternativ. Studien omfattar en kartläggning av dagvattenhantering inom distriktet, via en sådan undersökning har författarna lokaliserat två problem områden som bör ses över. Dessa är Hemlingbybäcken och Kryddstigen. Recipienten tillstånd d.v.s. Hemlingbybäcken påverkas av mänskliga aktiviteter. Föroreningar som drabbar bäcken utgörs av tungmetaller såsom koppar, bly och zink. Brist på dagvattenmagasiner har medfört att bäcken innehar kapacitetsproblem med dagvatteninflöde från närliggande fastigheter och industriområden. Kryddstigen är ett område där det bedrivs företag inom teknik och handel, dessa aktiviteter bidrar med föroreningar som försämrar grundvattnets och recipientens tillstånd. Norra delen av Hemlingby utgörs till största del av hårdgjorda ytor, vilket reducerar möjligheten för en naturlig infiltration och avvattning av nederbördsvatten, detta har i sin tur orsakat att översvämningsrisken ökat i distriktet. Gävle kommun har via tidigare utredningar identifierat problemet och försökt förebygga dessa genom att implementera fördröjningsdammar, våtmarksdammar och rondelldammar. Uppföljningsarbete har gjorts som konstaterar att dammarna har ett större avrinningsområde än tidigare beräknat, vilket påverkar verkningsgraden negativt. Kapacitetsproblem har därför uppkommit t.ex. våtmarksdammarna är dimensionerade att omhänderta ett 10-årsregn från ett avrinningsområde på 19 hektar. För tillfället klarar våtmarksdammarna endast av att hantera 2-årsregn för ett avrinningsområde på 2400m3. Studien presenterar öppen dagvattenhantering som lösningsalternativ för dessa områden, detta görs med hänsyn till befintliga VA-ledningar och dammar. Öppna dagvattenlösningar tillämpas oftast i urbana miljöer för att fördröja, lokalt omhänderta samt för att få en samlad fördröjning av dagvatten. Detta sker med hjälp av växtligheter som gör det möjligt att uppnå en naturlig infiltration. Allmänheten kan dra nyttja av att implementera öppna dagvattenlösningar. Det kan förvandla en tråkig stadsmiljö till en livlig sådan genom att omhänderta dagvatten ovanpå ytan. Det blir fördelaktigt för allmänheten eftersom öppna dagvattenlösningarna bidrar med en estetisk tilltalande miljö samt ökad biologiskmångfald. Alternativen redogörs på följande sätt: Gröna tak – LOD för privat mark, Permeabla markytor – Fördröjning nära källan &amp; LOD, Svackdiken med makadammagsin – Trög avledning &amp; Samlad fördröjning, Biofilteranläggning i form av Regnbäddar – samlad fördröjning. Lösningsförslagen har sedan bedömts ihop med nollalternativet utifrån inre och yttre aspekter som berör omhändertagande av dagvatten. Yttre aspekter omfattar lagstiftning och dagvattenpolicy, inre aspekter tar hänsyn till faktorer som ekonomiska, tekniska, sociala och miljömässiga förhållanden. Bedömningsmetoden som presenteras i studien syftar till att utvärdera och ta fram underlag som är relevanta vid beslutsfattning och framtagning av tekniska lösningar. Värderingsmetoden är inspirerad av PESTEL-analys modellen. I denna undersökning har denna metod anpassats för att bedöma dagvattenlösningar. Övergripande beskrivning av vad en PESTEL-analys är ges i rapporten samt tolkning och tillämpning av bedömningsmetoden. Bedömningsresultateten för enskilt alternativ presenteras och diskuteras med hänsyn till nollalternativet samt tillämpningsområde i rapporten. / The aim of this study is to propose appropriate solutions that can complete Hemlingbys existing stormwater treatment systems. The solutions presented in this study has been developed with regards to the current situation, which includes water drainage systems and ponds. The study includes a survey of the current stormwater management within the district, as a result, the authors have localized two problem areas that should be investigated, i.e. are Hemlingbybäcken and Kryddstigen. The stormwater recipient i.e. Hemlingbybäcken is affected by human activities. Contaminates that affect the stream consist mainly of copper, lead and zinc. Due to the lack of stormwater storage capacity problems associated with stormwater flooding occurred from nearby buildings and industrial areas. Kryddstigen is an area in the district where business in technology and trade are located, these activities contribute to pollution that degrades groundwater and recipient conditions. The northern part of Hemlingby consist mostly of hard surfaces, which reduces the possibility of a natural infiltration of rain water, this in turn has caused an increased risk of flooding in the area. Gävle municipality have through earlier investigations identified some of the problems and tried to prevent them by implementing ponds that can delay incoming stormwater. Follow-up works proves that the ponds serve a larger catchment area than previously estimated, which adverse the ponds efficiency. Capacity problems have therefore arisen, for instance wetland ponds are sized to handle 10-yearsrain from a catchment area of 19 hectares. However, the existing wetland ponds can only handle a 2-yearsrain from a catchment area of 2400m3. This study presents open stormwater management as alternative solution, this has been proposed based on existing sewerage systems and ponds. Open stormwater solutions are applied mostly in urban environment to delay and locally dispose stormwater. This is done by vegetation which makes it possible to achieve a natural infiltration. The public can also take use of open stormwater solutions by turning an unattractive city to a beautiful one. It can also be beneficial to the community because open stormwater solutions contribute with an aesthetically pleasing environment and increasing biodiversity. The alternatives are described as follows: Green roofs, permeable ground surfaces, ditch with macadam basin and, rain gardens. These solutions are then assessed together with the existing solutions based on internal and external aspects concerning stormwater management. External aspects include legislation and stormwater policy, internal aspects take into account factors such as economy, technology, social and environment conditions. Assessment methodology that are presented in this study aims to evaluate and prepare documentation that is relevant for decision- making and the development of technical solutions based on the current situation. The evaluation method used in this study is inspired by PESTEL- analysis model. This method has been adapted to assess stormwater solutions. An overall description of what a PESTEL- analysis is given in this study as well as the interpretation and application of the assessment method. The result for single alternatives is presented and discussed with respect to existing solutions in the area of this study.

Page generated in 0.0473 seconds