• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 73
  • 24
  • 18
  • 16
  • 5
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 233
  • 233
  • 90
  • 75
  • 55
  • 46
  • 44
  • 42
  • 41
  • 40
  • 39
  • 36
  • 35
  • 35
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Gestão energética nos setores transversais para redução do consumo de energia em uma empresa automobilística / Management energy sectors in cross for reducing power consumption in a company automotive

Castro, Alexandre Teles de [UNESP] 04 March 2016 (has links)
Submitted by ALEXANDRE TELES DE CASTRO null (axandre1@hotmail.com) on 2016-05-12T03:47:57Z No. of bitstreams: 1 Dissertação Alexandre_27_04_2016_Versão FINAL.docx: 2706941 bytes, checksum: 571c1689b57b8c4f5187e8c13a74c86b (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-12T18:31:09Z (GMT) No. of bitstreams: 1 castro_at_me_guara.pdf: 2054530 bytes, checksum: 9738a869d771260980ea50f64ba32192 (MD5) / Made available in DSpace on 2016-05-12T18:31:09Z (GMT). No. of bitstreams: 1 castro_at_me_guara.pdf: 2054530 bytes, checksum: 9738a869d771260980ea50f64ba32192 (MD5) Previous issue date: 2016-03-04 / Este trabalho visa analisar a energia elétrica das instalações elétricas, os consumos de energia elétrica, ar comprimido e água gelada, criação de novos indicadores de desempenho energético e uso de ferramentas estatísticas em uma empresa montadora de veículos. Seu principal objetivo é obter novos indicadores de desempenho energético, redução do consumo de energia elétrica em uma pesquisa ação, com a necessidade de encontrar reduções de consumo de energia nas áreas das utilidades, água gelada, água quente, ar comprimido, energia elétrica nas áreas transversais. Dentre os insumos utilizados pelas indústrias, a energia elétrica insere-se como recurso essencial em quase todas as atividades de um sistema produtivo. Dessa forma, são evidenciados os consumos de maior relevância nas áreas de utilidades e nas áreas transversais. O investimento no uso eficiente de energia elétrica traz uma série de benefícios para a empresa, para o país e para seu cliente final. Dentre os aspectos econômicos envolvidos na atividade de racionalização do uso de energia, deve-se destacar a valorização da imagem e da visão estratégica da empresa. São evidenciados os novos indicadores de desempenho energético nos setores transversais e nas utilidades, mensais. Não houve correlação dos consumos de energia elétrica entre os prédios. As tendências de consumo de ar comprimido e água gelada mostraram uma incompatibilidade, observado nos gráficos de correlação. / This work aims to analyze the demand for electric energy, electric energy consumption, compressed air and chilled water, creating new indicators of energy performance and use of statistical tools in a vehicle assembly company. Its main objective is to obtain new indicators of energy performance, reduced power consumption in an action research, with the need for energy consumption reductions in the areas of utilities, cold water, hot water, compressed air, chilled water, energy electric in cross-cutting areas. Among the inputs used by industries, the electricity is part of an essential feature in almost all activities of a production system. Thus, it is highlighted the most relevant consumption in the areas of utilities and in cross-cutting areas. Investment in energy-efficient brings a number of benefits for the company, for the country and for your end customer. Among the economic aspects involved in rationalizing activity of energy use, it should be noted to enhance the image and the strategic vision of the company. It will be shown the new energy performance indicators in cross-cutting sectors and the utilities, monthly. There was no correlation of electric energy consumption between buildings. The compressed air consumption trends and chilled water showed a mismatch, seen in correlation graphs.
112

Commande faible coût pour une réduction de la consommation d'énergie dans les systèmes électroniques embarqués / Reduction of the energy consumption in embedded electronic devices with low control computational cost

Durand, Sylvain 17 January 2011 (has links)
La course à la miniaturisation des circuits électroniques pousse à développer des systèmes faible coût, quece soit en terme de consommation d’énergie ou de ressources de calcul. Il est ainsi possible de réduire la consommationen diminuant la tension d’alimentation et/ou la fréquence d’horloge, mais ceci a pour conséquence de diminuer aussila vitesse de fonctionnement du circuit. Une commande prédictive rapide permet alors de gérer dynamiquement un telcompromis, de manière à ce que la consommation d’énergie soit minimisée tout en garantissant de bonnes performances.Les stratégies de commande proposées ont notamment l’avantage d’être très robustes aux dispersions technologiquesqui sont un problème récurrent dans les nanopuces. Des solutions sont également proposées afin de réduire le coût decalcul du contrôleur. Les systèmes à échantillonnage non-uniforme, dont la loi de commande est calculée et mise à jourlorsqu’un événement est déclenché, sont ainsi étudiés. Ce principe permet de réduire le nombre d’échantillons et, parconséquent, d’économiser des ressources de calcul, tout en garantissant de bonnes performances du système commandé.Des résultats de simulation, et surtout expérimentaux, valident finalement l’intérêt d’utiliser une telle approche. / The demand of electronic components in all embedded and miniaturized applications encourages to developlow-cost components, in term of energy consumption and computational resources. Actually, the power consumption canbe reduced when decreasing the supply voltage and/or the clock frequency, but with the effect that the device runs moreslowly in return. Nevertheless, a fast predictive control strategy allows to dynamically manage this tradeoff in order tominimize the energy consumption while ensuring good performance of the device. Furthermore, the proposals are highlyrobust to tackle variability which is a real problem in nanometric systems on chip. Some issues are also suggested inthis thesis to reduce the control computational cost. Contrary to a time-triggered system where the controller calculatesthe control law at each (constant and periodic) sampling time, an event-based controller updates the control signalonly when the measurement sufficiently changes. Such a paradigm hence calls for resources whenever they are indeednecessary, that is when required from a performance or stability point of view for instance. The idea is to soften thecomputational load by reducing the number of samples and consequently the CPU utilization. Some simulation andexperimental results eventually validate the interest of such an approach.
113

Energy Performance Contracting in Swedish scenario: a case study with Morastrand AB

Frota de Albuquerque Landi, Fabiana January 2018 (has links)
Renovation of the existing buildings in Sweden represents a great potential to achieve the energy efficiency and carbon emission targets set by the European Union and the Swedish government. The Energy Performance Contracting (EPC) is regarded as an efficient way to manage and to outsource the risks of energy efficiency (EE) measures. The thesis aims to identify the theoretical framework of EPC in the Swedish scenario and, through a real case, develop a model that relates EE measures and its results considering the capital investment versus running costs of renovation projects. The work is based on the incorporation with the Morastrand AB. The research expects to assess EPC processes and measures as in Energy Service Companies (ESCO) and consequently help in the decision making and the management of the projects. The thesis is composed of two parts. The first part identifies the theoretical framework of energy contract models focusing on the EPC, while a case study with Morastrand AB is subsequently presented. It is suggested one approach for the preliminary comparison of different renovation measures in EE projects, corresponding to the first step of the planning phase of an EPC. General recommendations and sensitive factors were identified and can assist Morastrand AB to effectively implement EE projects in the future. For orienting investments, the Lifecycle Cost Analysis (LCCA) is a method to study solutions under economic aspects and further it can be extended to the complete Lifecycle Assessment of the upcoming projects. The theoretical framework of the EPC is composed by identifying the projects, performing the technical analysis, determinizing the potential in energy savings, deepening the analysis with auditions, tendering the project, designing and executing the project, commissioning, operating and supporting the systems with constant monitoring and maintenance. The biggest challenge for the EPC in Sweden is the relation between the ESCOs and their clients. The figure of the facilitator could improve the results and balance the knowledge gap between the parts. The actors of these projects are the ESCO, the client, the facilitator and the financing part. In Sweden, very frequently the client finances the operation. There are a few models of contracting, and the most popular are guaranteed savings and shared savings. The thesis performed the LCCA of three options for window replacement in a building at the end of its lifespan. The results show that the trends in prices and interest rates are sensitive factors. In this case, the projects with higher initial investments were more profitable. Those solutions can shield the company against energy prices escalates and contribute to the green policies.
114

A contribuição da conservação de energia elétrica em instalações residenciais e seu impacto no planejamento da expansão da geração futura, com base na análise do Programa de Eficiência Energética - PEE desenvolvidas pelas concessionárias de energia elétrica no Brasil. / The contribution of the conservation of electric energy in residential installations and its impact in the planning of the expansion of the future generation, based on the analysis of the Energy Efficiency Program - PEE developed by the electric power concessionaires in Brazil.

Santos, Rodolfo Esmarady Rocha dos 20 August 2018 (has links)
Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-13T14:59:07Z No. of bitstreams: 1 Tese_Rodolfo Esmarady Rocha dos Santos.pdf: 4337307 bytes, checksum: 1ff22a01eebe75138eb15230f51aa481 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo • De acordo com a contagem das páginas seu trabalho deve com o número (21), após você precisa atualizar a numeração na ficha catalográfica, nas listas e no sumário. • As palavras-chave e keyword devem ser separadas entre si por ponto final e também finalizadas por ponto. (favor ver exemplo no template ou diretrizes) • Referências. A palavra Referências deve ser centralizada, e não conter numeração de seção; As referencias devem ser justificadas, espaço simples com um espaço simples(enter) entre elas. • Sobre a elaboração das referencias e citações favor solicitar ajuda com a bibliotecária Juciene (juciene@feg.unesp.br) Mais informações acesse o link: http://www2.feg.unesp.br/Home/Biblioteca21/diretrizes-2016.pdf Agradecemos a compreensão. on 2018-09-13T17:47:09Z (GMT) / Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-14T18:39:56Z No. of bitstreams: 1 Tese final_Rodolfo Esmarady Rocha dos Santos.pdf: 4339037 bytes, checksum: 1fe49e11c895d0d0fbeb9a2fd39824cf (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: É necessário rever suas referências, para tanto entre em contato com a bibliotecária Juciene (juciene.pedroso@unesp.br) para devidas correções Mais informações acesse o link: http://www2.feg.unesp.br/Home/Biblioteca21/diretrizes-2016.pdf Agradecemos a compreensão. . on 2018-09-14T20:02:42Z (GMT) / Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-15T01:26:06Z No. of bitstreams: 1 Tese_versão_f_Rodolfo Esmarady Rocha dos Santos.pdf: 4937602 bytes, checksum: d89a0e5cbb78c7f5a03c1c73a13d9155 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: É necessário rever suas referências, para tanto entre em contato com a bibliotecária Juciene (juciene.pedroso@unesp.br) para devidas correções. Neste sentido, você deve enviar o arquivo de sua dissertação em que constam as referências para que ela possa te indicar o que deve corrigir de acordo com as normas da ABNT 6023 e ou agendar para tirar dúvidas pessoalmente com ela. Agradecemos a compreensão. on 2018-09-17T14:54:26Z (GMT) / Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-19T17:47:39Z No. of bitstreams: 1 Tese final_Rodolfo E R Santos.pdf: 4331564 bytes, checksum: dfd13fc66380afb68b3599c4528a5e4d (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-09-20T14:43:30Z (GMT) No. of bitstreams: 1 santos_rer_dr_guara.pdf: 4331564 bytes, checksum: dfd13fc66380afb68b3599c4528a5e4d (MD5) / Made available in DSpace on 2018-09-20T14:43:30Z (GMT). No. of bitstreams: 1 santos_rer_dr_guara.pdf: 4331564 bytes, checksum: dfd13fc66380afb68b3599c4528a5e4d (MD5) Previous issue date: 2018-08-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Programa de Eficiência Energética (PEE) das distribuidoras de energia elétrica é, atualmente, o principal mecanismo de destinação de recursos para a promoção do uso racional de energia no Brasil. Ao longo do período de 2000 a 2017, este instrumento proporcionou importantes alterações, como a implementação da Lei nº 12.212/2010, que determinou a aplicação da maior parcela dos recursos aos projetos de iluminação, troca de refrigeradores, reforma das instalações elétricas e aquecedores destinados a população de baixa renda. Neste contexto, para este estudo, foi desenvolvido um Software de Análise PEE responsável pela seleção das informações dos relatórios propostos e realizados do PEE, disponibilizado pela Agência Nacional de Energia Elétrica (ANEEL), possibilitando o acesso às informações relevantes contidas nos projetos. Em posse desses dados, foi possível determinar a economia de energia total de 3.190,12 GWh e redução de demanda na ponta de 1.168,05 MW para o período de análise abordado de 2009 a 2015, para os usos finais em iluminação e refrigeração. Na sequência do estudo, foi realizada uma avaliação sobre o impacto ambiental relacionado à redução de emissão de CO2, com a aplicação da metodologia proposta para o PEE da ANEEL, e pode-se verificar que foi evitada a emissão total de 1.244.457,02 tCO2 para o uso final em iluminação e 169.570,05 tCO2 para refrigeração (refrigerador), totalizando 1.414.027,07 tCO2 ao longo do período de 2009 a 2015. O foco principal desse estudo foi o desenvolvimento das novas Relações Custo-benefício (RCB) onde obteve-se para o uso final em iluminação uma RCB entre (0,10 a 0,18) para os cálculos tradicionais e RCB entre 0,08 a 0,17 adotando as Reduções Certificadas de Emissões (RCE) calculadas com a redução do CO2, demostrando que ambos resultados ficaram inferior ao máximo estabelecido pela ANEEL, proporcionando assim uma contribuição significativa para os demais projetos do PEE. Para o uso final em refrigeração os resultados apresentaram uma RCB tradicional entre 0,97 a 1,62 e, incrementando as RCEs, o resultado apresentou as RCBs entre 0,97 a 1,60. No caso do uso final em refrigeração ambos resultados superam o máximo estabelecido pela ANEEL, demostrando que a utilização deste uso final, isoladamente, não é viável para os projetos do PEE. E, por fim, foi possível desenvolver uma Usina Virtual Equivalente (UVE), adotando os custos reais médios das construções das Usinas Hidrelétricas (UHE) e de Pequenas Centrais Hidrelétricas (PCHs), e obtendo-se uma UVE de 77,27 MW de potência total, para os projetos analisados. No entanto, apesar das discussões ao redor desta temática, os projetos do PEE promovem melhorias relacionadas à demanda de energia e economia de energia elétrica para os consumidores dos usos finais abordados. Desse modo, foi de extrema importância acompanhar o desempenho energético destes projetos, nos quais foram identificados fatores que podem potencializar os resultados, de acordo com a região onde serão aplicados. Além disso, a economia de energia poderá contribuir com a Empresa de Planejamento Energético (EPE), que vem desenvolvendo trabalhos para incluir nos Planos Decenais de Expansão de Energia (PDE 2026) tais resultados, provenientes das ações de eficiência energética. / The Energy Efficiency Program (PEE) of energy distributors is currently the main mechanism for allocating resources for the advancement of rational energy use in Brazil. Over the period from 2000 to 2017, this tool has undergone important changes, such as the implementation of Law 12,212 / 2010, which has determined the application of most of the resources to lighting projects, fridge replacement, electrical and heaters installation aimed at a low-income population. In this context, a PEE Analysis Software was developed for this study, which was used to select information from PEE proposed and performed reports, provided by the National Electric Energy Agency (ANEEL), allowing access to the relevant information contained in the projects. Based on these data, it was possible to determine a total energy saving of 3,190.12 GWh and demand reduction at peak of 1,168.05 MW for the analysis period from 2009 to 2015. Following the study, it was conducted an assessment on the environmental impact related to CO2 emission reduction, with the application of the methodology proposed for the ANEEL PEE, and it can be verified a total emission of 1,244,457.02 tCO2 for the end use in illumination and 169,570.05 tCO2 for cooling (fridge), totalizing 1,414,027.07 tCO2 over the period from 2009 to 2015. The study main focus was the development of the new Cost-benefit Ratio (RCB), where an RCB between 0.10 and 0.18 was obtained for the end use in lighting for traditional calculations and RCB between 0.08 to 0.17 adopting the Certified Emissions Reductions (CERs) calculated with the reduction of CO2, proving that both results were lower than the maximum established by ANEEL, thus providing a significant contribution to the other SES projects. For the end use in cooling, the results presented a traditional RCB between 0.97 and 1.62 and, increasing the CERs, the result showed the RCBs between 0.97 and 1.60. In the case of end use in cooling, both results exceed the maximum set by ANEEL, demonstrating that the application of this end use, alone, is not feasible for the PEE projects. Finally, it was possible to develop an Equivalent Virtual Power Plant (UVE), adopting the average real costs of the Hydroelectric Power Plant (HPP) and Small Hydroelectric Power Plant (PCH) buildings, obtaining a UVE of 77.27 MW of total power, for the analyzed projects. However, in spite of the discussions around this issue, the PEE projects promote improvements related to the demand of energy and electricity saving for the consumers of the end uses addressed. Thus, it was extremely important to follow these projects energy performance, in which factors that could potentiate the results were identified, according to the region where they will be applied. In addition, energy savings can contribute to the Energy Planning Company (EPE), which has been developing works to include such results in the Energy Efficiency Actions in the Ten-Year Energy Expansion Plan (PDE 2026)
115

A Influência do sombreamento e da absortância da envoltória no desempenho térmico e energético de edificações residenciais multipavimentos na cidade de João Pessoa-PB / The influence of shading and absortance of the envelope in the thermal and energy performance of residential buildings in João Pessoa-PB

Martins, Lúcia Helena Aires 30 September 2013 (has links)
Made available in DSpace on 2015-05-14T12:09:28Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 11490325 bytes, checksum: c5db739b54c8a079086312556753c528 (MD5) Previous issue date: 2013-09-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Given the importance of adaptation of the building to the climate in search of more thermally and energy efficient buildings, this study evaluates the influence of shading devices and solar absorption coefficient of the envelope in the thermal and energy performance of residential buildings located in the Manaíra, João Pessoa-PB , through computer simulations, using the DesignBuilder program. The work involved the development of a methodology for the identification of the main characteristics of residential buildings in urban cutout study. Were analyzed 25 buildings with respect to: frequency of occurrence of numbers of floors, terrain and edification shape, area of apartments, percentage area of window and of wall in the facades, facade orientation, existence of elements of sun protection and constructive characteristics general. Based on the data collected, a representative model of constructive reality was elaborated, called predominant typology and used as the base case in the simulations. One set of typologies was simulated, determined from alterations constructive variables such as solar protection and absorption coefficient of the envelope, as well as, the urban variable surroundings obstruction. The analysis variables considered were the temperature of the internal air, solar gain through opaque and transparent closings and load required for cooling. Was observed that the shading caused in the area around contributes to a reduction in internal temperature and solar gain, but the balance is not always favorable, some models analyzed presented an increase in solar gain by opaque closings. Just like the density of surrounding area can elevate the air temperature and energy consumption in domestic environments. The use of the shutter openings resulted in better thermal and energy performance, higher than the adoption of low absorption coefficient ( = 0.20). / Diante da importância da adequação da edificação ao clima em busca de edificações mais eficientes termicamente e energeticamente, este trabalho avalia a influência dos dispositivos de sombreamento e do coeficiente de absorção solar da envoltória no desempenho térmico e energético de edifícios residenciais multipavimentos localizados no bairro de Manaíra, município de João Pessoa-PB, através de simulações computacionais, utilizando o programa DesignBuilder. O trabalho compreendeu o desenvolvimento de uma metodologia para o levantamento das principais características de edifícios residenciais multipavimentos no recorte urbano em estudo. Foram analisados 25 edifícios com relação à: frequência de ocorrência de números de pavimentos, forma do terreno e da edificação, área dos apartamentos tipo, percentual de área de janela e de parede nas fachadas, orientação das fachadas, existência de elementos de proteção solar e características construtivas gerais. Com base nos dados levantados, um modelo representativo da realidade construtiva foi elaborado, denominada de tipologia predominante e utilizada como caso base das simulações. Um conjunto de tipologias foi simulado, determinado a partir de alterações de variáveis construtivas, como proteção solar e coeficiente de absorção da envoltória, assim como, a variável urbana obstrução do entorno. As variáveis de análise consideradas foram a temperatura do ar interna, o ganho solar através dos fechamentos opacos e transparentes e a carga necessária para resfriamento. Observou-se que o sombreamento provocado pelo entorno contribui para a redução da temperatura interna e ganho de calor, porém nem sempre o balanço é favorável, alguns modelos analisados apresentaram um aumento no ganho solar pelos fechamentos opacos. Assim como, o adensamento do entorno, pode elevar a temperatura do ar e o consumo de energia nos ambientes internos. O uso da veneziana nas aberturas resultou no melhor desempenho térmico e energético, superior à adoção de baixo coeficiente de absorção (=0,20).
116

Influ?ncia de vari?veis arquitet?nicas no desempenho energ?tico de hot?is no clima quente e ?mido da cidade de Natal/RN

Lima, Gl?nio Leilson Ferreira 01 February 2007 (has links)
Made available in DSpace on 2014-12-17T13:57:23Z (GMT). No. of bitstreams: 1 GlenioLFL.pdf: 3500534 bytes, checksum: d4ce541fabad7066b400594c3c70b44c (MD5) Previous issue date: 2007-02-01 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages / O objetivo deste trabalho foi identificar as decis?es arquitet?nicas mais importantes relacionadas com a redu??o do consumo energ?tico em hot?is. A partir de auditorias realizadas em 43 meios de hospedagem da cidade foi poss?vel conhecer mais suas formas de funcionamento, seus equipamentos, sistema de ilumina??o, tipos de condicionadores de ar, al?m de caracter?sticas construtivas. Os dados dessa pesquisa de campo foram organizados e os aspectos mais relevantes foram utilizadas na modelagem de um caso representativo. Com base nesse modelo inicial, simula??es computacionais foram realizadas com a finalidade de se verificar o impacto de diferentes alternativas de projeto no consumo de energia. Entre as vari?veis analisadas est?o a efici?ncia do sistema de resfriamento, a orienta??o, o sombreamento, o tamanho das aberturas, o tipo de vidro, al?m de caracter?sticas t?rmicas de parede e coberta. Os resultados demonstraram a import?ncia das rotinas de ocupa??o na defini??o das estrat?gias projetuais, as combina??es com melhor e pior desempenho em rela??o ao modelo inicial, identificaram os casos em que determinada vari?vel tem seu efeito minimizado/maximizado sobre o consumo, al?m de quantificar o impacto produzido na combina??o de uma, duas ou mais alternativas de projeto. As an?lises evidenciaram ainda a complexidade que a coleta de dados envolve, as peculiaridades do setor hoteleiro e a dificuldade de se estabelecer correla??es claras com o consumo, sobretudo pelas incertezas associadas ? imprevisibilidade de uso nos hot?is e aus?ncia de crit?rios/normas de classifica??o
117

Gestão energética nos setores transversais para redução do consumo de energia em uma empresa automobilística /

Castro, Alexandre Teles de January 2016 (has links)
Orientador: José Antonio Perrella Balestieri / Resumo: Este trabalho visa analisar a energia elétrica das instalações elétricas, os consumos de energia elétrica, ar comprimido e água gelada, criação de novos indicadores de desempenho energético e uso de ferramentas estatísticas em uma empresa montadora de veículos. Seu principal objetivo é obter novos indicadores de desempenho energético, redução do consumo de energia elétrica em uma pesquisa ação, com a necessidade de encontrar reduções de consumo de energia nas áreas das utilidades, água gelada, água quente, ar comprimido, energia elétrica nas áreas transversais. Dentre os insumos utilizados pelas indústrias, a energia elétrica insere-se como recurso essencial em quase todas as atividades de um sistema produtivo. Dessa forma, são evidenciados os consumos de maior relevância nas áreas de utilidades e nas áreas transversais. O investimento no uso eficiente de energia elétrica traz uma série de benefícios para a empresa, para o país e para seu cliente final. Dentre os aspectos econômicos envolvidos na atividade de racionalização do uso de energia, deve-se destacar a valorização da imagem e da visão estratégica da empresa. São evidenciados os novos indicadores de desempenho energético nos setores transversais e nas utilidades, mensais. Não houve correlação dos consumos de energia elétrica entre os prédios. As tendências de consumo de ar comprimido e água gelada mostraram uma incompatibilidade, observado nos gráficos de correlação. / Abstract: This work aims to analyze the demand for electric energy, electric energy consumption, compressed air and chilled water, creating new indicators of energy performance and use of statistical tools in a vehicle assembly company. Its main objective is to obtain new indicators of energy performance, reduced power consumption in an action research, with the need for energy consumption reductions in the areas of utilities, cold water, hot water, compressed air, chilled water, energy electric in cross-cutting areas. Among the inputs used by industries, the electricity is part of an essential feature in almost all activities of a production system. Thus, it is highlighted the most relevant consumption in the areas of utilities and in cross-cutting areas. Investment in energy-efficient brings a number of benefits for the company, for the country and for your end customer. Among the economic aspects involved in rationalizing activity of energy use, it should be noted to enhance the image and the strategic vision of the company. It will be shown the new energy performance indicators in cross-cutting sectors and the utilities, monthly. There was no correlation of electric energy consumption between buildings. The compressed air consumption trends and chilled water showed a mismatch, seen in correlation graphs. / Mestre
118

Método graus dia para avaliação do desempenho energético de uma edificação unifamiliar em diferentes condições climáticas. / Method degrees-day for evaluation of the energy performance of a construction unifamiliar in different climatic conditions.

Vendramin, Aurea Lúcia 12 July 2007 (has links)
Made available in DSpace on 2017-07-10T19:23:56Z (GMT). No. of bitstreams: 1 Aurea Lucia Vendramini.pdf: 426775 bytes, checksum: 564553d1ce5ca6d797acb90f3cf07ad3 (MD5) Previous issue date: 2007-07-12 / The necessity of the application of climatic data for evaluation of energy performance in unifamiliares constructions if has become each more important time. Attempting against for this fact, one becomes necessary that these 0 variable are worked of form if to get resulted efficient. Studies in this area are very recent in Brazil and also exist a difficulty in the survey of the necessary registers. The present work used a method of degrees - days for an evaluation of the energy performance of a unifamiliar construction it showed - that in the conception of a project architectural it always must be taken in consideration of the materials used in the construction and size of the openings. The energy performance was gotten by means of the model of degrees - days, considering - the localization of the unifamiliar residence in, cities of Cascavel, Curitiba, Foz do Iguaçu and Londrina. For this the climatic data of such localities had been gotten and at as a moment, the energy performance of the construction was gotten the total coefficient of loss of heat in the unifamiliar construction daily pay-established evaluating thus the conditions of thermal comfort. The method of estimate based on the information of used temperature of air in this study can be applied to other geographic localities. It observed - that degrees - days of heating in the winter are of 77.78 for Curitiba and 0.00 for Foz do Iguaçu in the temperature base of 14°C. E degrees - days of cooling 30,17 in the winter. The energy consumed in Foz do Iguaçu to heat the residence is of 4650.07 kWh annual and the consumption of annual energy to heat the residence in Curitiba is of 6277.02 kWh, to change of 50% ITA in double glass. / A necessidade da aplicação de dados climáticos para avaliação de desempenho energético em edificações unifamiliares tem se tornado cada vez mais importante. Atentando para esse fato, é necessário que essas variáveis sejam trabalhadas de forma a se obter resultados eficazes. Estudos na área são muito recentes no Brasil e existe também uma dificuldade no levantamento dos registros necessários. O presente trabalho utilizou um método de graus dias para uma avaliação do desempenho energético de uma edificação unifamiliar que mostrou que na concepção de um projeto arquitetônico devem ser sempre considerados os materiais empregados na edificação e o tamanho das aberturas. O desempenho energético foi obtido por meio do modelo de graus dias, considerando se a localização da residência unifamiliar nas cidades de Cascavel, Curitiba, Foz do Iguaçu e Londrina. Para isso foram obtidos os dados climáticos dessas localidades e, em um segundo momento, foi obtido o coeficiente total de perda de calor na edificação unifamiliar pré-estabelecida avaliando-se assim as condições de conforto térmico o desempenho energético da edificação. O método de estimativa baseado nas informações de temperatura do ar usado neste estudo pode ser aplicado a outras localidades geográficas. Observou se que graus dias de aquecimento no inverno são de 77,78 para Curitiba e de 0,00 para Foz do Iguaçu na temperatura base de 14°C. E graus dias de resfriamento 30,17 no inverno. A energia consumida em Foz do Iguaçu para aquecer a residência é de 4650.07 kWh anual e o consumo de energia anual para aquecer a residência em Curitiba é de 6277.02 kWh, para trocas de 50% de ITA em vidros duplos.
119

Simulação de desempenho energético de tecnologias fotovoltaicas em fachada de edifício no município de São Paulo. / Energy performance simulation of photovoltaic technologies on the building facade in São Paulo.

Alvaro Nakano 25 May 2017 (has links)
As tecnologias usualmente aplicadas no mercado fotovoltaico mundial são, em sua maioria, voltadas aos painéis rígidos de células de silício cristalino, em função da redução de seus preços proporcionada pela economia de escala. No entanto, a crescente demanda no País de novos domicílios, principalmente de apartamentos, tem exigido soluções mais apropriadas: com menor ocupação de área horizontal e instaladas na fachada dos edifícios. Nesse sentido vão surgindo tecnologias fotovoltaicas como as de filmes finos como soluções mais apropriadas do que as emergentes de terceira geração, pelo fato dessas últimas ainda se encontrarem em fase de maturação técnica com poucas opções de fornecimento no mercado em nível comercial. Portanto, a abordagem desta dissertação se limitou às tecnologias de filmes finos e de vidros fotovoltaicos semi transparentes, além daquela mais usual que é a de silício cristalino. Contudo, o dinamismo do mercado mundial vem estimulando uma evolução no fator de desempenho dessas tecnologias, o que justificou a necessidade de uma revisão bibliográfica. Além disso, a maioria dos projetos fotovoltaicos vem adotando como base os painéis rígidos com células de silício cristalino, sem, no entanto, avaliarem alternativas com a aplicação de outras tecnologias. O que se nota é a falta de conhecimento mais profundo dos projetistas sobre as tecnologias de filmes finos e das melhores opções para sua aplicação em um edifício, no que tange ao seu desempenho e seu comportamento dentro do espectro de frequência. Assim, esta dissertação teve por objetivo contribuir com uma análise de desempenho energético com base em simulações para tomada de decisão técnica sobre as tecnologias mais adequadas de célula fotovoltaica para sistemas a serem instalados em fachadas de edifícios, auxiliadas por uma ferramenta computacional existente no mercado, o PVSYST. A tomada de decisão foi vista pela perspectiva de desempenho na geração de energia elétrica, pela análise comparativa dos resultados de simulações aplicadas na fachada de um edifício hipotético em São Paulo. Os resultados mostraram que as tecnologias baseadas no silício cristalino são as mais adequadas nos casos em que o pico de demanda de energia no ano seja no verão, como nos edifícios comerciais. Já os sistemas compostos pelos filmes finos do grupo do seleneto de índio e cobre são os mais indicados para os edifícios residenciais, em que o período de maior demanda é no inverno. / Technologies commonly applied in the global photovoltaic market are mostly with the rigid panels of crystalline silicon cells, due to the reduction of their prices provided by economies of scale. However, growing demand in the country of new housing units, mainly apartments, has required more appropriated solutions: with lower occupancy of horizontal area and installed on the building\'s facade. In this direction photovoltaic technologies are emerging such as thin films as better solutions than the emerging technologies of third generation, because still they are in technical maturation phase with few options of suppliers in the commercial market. Therefore, the approach of this dissertation was limited to technologies of thin films and semitransparent photovoltaic glazing, in addition to the more usual one that is crystalline silicon. However, the dynamism of the global market has stimulated an evolution in the performance factor of these technologies, which justified the necessity of literature review. Furthermore, most PV projects have been based on the rigid panels with crystalline silicon cells, not considering the alternatives using other technologies. What is noticed is the lack of deeper understanding of the designers about the thin film technologies and the best options for their application in a building, in terms of their performance and their behavior within the frequency spectrum. Thus, this work aimed to contribute to an energy performance analysis based on simulations for technical decision on the most appropriate photovoltaic cell technologies for systems to be installed on the facades of buildings, aided by an existing software tool on the market, PVSYST. Decision making was seen from the perspective of performance in electricity generation, by comparative analysis of simulations results applied on the facade of a hypothetical building in São Paulo. The results showed that the technologies based on crystalline silicon are the most appropriate in cases where energy demand peak in the year is in the summer, as in commercial buildings. On the other hand, the systems composed of the thin films based on indium and copper selenium group are the most suitable for residential buildings, where the period of greatest demand is in the winter.
120

Comparação do desempenho energético entre sistema de condicionamento de ar com distribuição pelo piso e pelo teto, utilizando o modelo computacional EnergyPlus. / Comparison of the energy performance between air conditioning system with floor and ceiling distribution, using the EnergyPlus computational model.

Gabriel Adão Borges 19 April 2018 (has links)
Em pauta já há algum tempo, os impactos ambientais, possivelmente gerados pela ação humana, são cada vez mais discutidos e estudados. A busca por um desenvolvimento sustentável e formas mais eficientes do consumo de energia é abordada frequentemente. No Brasil, os edifícios comerciais e públicos apresentam alta demanda de energia elétrica e os sistemas de condicionamento de ar são responsáveis por uma parcela relevante do consumo no país. Para mitigar esse consumo, o sistema de ar condicionado distribuído pelo piso tem sido proposto como uma solução, pois este é intrinsecamente mais eficiente que o sistema de ar condicionado convencional, com distribuição de ar pelo teto. O presente trabalho tem como propósito identificar o potencial de economia de energia de um sistema de condicionamento de ar com distribuição pelo piso em relação a um sistema com distribuição pelo teto, por meio da simulação computacional. Avaliaram-se também o impacto do aumento da temperatura de insuflação e do pé-direito da edificação, além do uso de ciclo economizador (controle entálpico) aplicado aos sistemas na economia de energia. Para a modelagem computacional, realizada pela ferramenta computacional EnergyPlus, tomou-se como referência uma sala de aula que contém um sistema de condicionamento de ar com distribuição pelo piso. O primeiro sistema modelado foi pelo piso, e este serviu como base para a modelagem do sistema pelo teto. Após a criação dos modelos foram executadas as simulações cujos resultados permitiram a comparação entre os consumos de energia de cada um dos sistemas. Em conformidade com a literatura, onde se afirmam que os sistemas com distribuição de ar pelo piso são mais eficientes que os convencionais (distribuição de ar pelo teto), este trabalho também concluiu que este sistema é mais eficiente, apresentando um indicador de economia de energia da ordem de 33%, para a condição: pé-direito de 3,50 m; temperatura de insuflação de 19 °C; e controle entálpico. Os resultados desta pesquisa indicam ainda que a utilização do controle entálpico tem maior influência na economia de energia se comparada ao aumento da temperatura de insuflação ou do pé-direito. / On the agenda for some time, the environmental impacts, possibly generated by human action, are increasingly discussed and studied. The demand for sustainable development and more efficient ways of energy consumption is often addressed. In Brazil, commercial and public buildings have high demand for electricity and air conditioning systems are responsible for a significant portion of this consumption in the country. The underfloor air conditioning system has been proposed as a solution to mitigate such consumption because it is intrinsically more efficient than the ceiling-based air conditioning system. The present work aims to identify the energy saving potential of an air conditioning system with underfloor air distribution comparatively to a system with ceiling air distribution, through computational simulation. Also, the impact of increased supply air temperature and the floor to ceiling height, and the use of the economizer cycle (enthalpy control) was evaluated. For the computational modeling, carried out by the EnergyPlus computational tool, a classroom that contains an air conditioning system with floor distribution was used as reference. The first modeled air distribution system was the underfloor air distribution system, and this served as a basis for the modeling of the ceiling air distribution system. After performing the models, the simulations were carried out, whose results allowed the comparison the energy consumptions between the two systems. According to the literature, where it is stated that the systems with underfloor air distribution are more efficient than the conventional ones (ceiling air distribution), this work also concludes that the system with underfloor air distribution is more efficient, presenting an energy saving indicator around 33%, for the following condition: floor to ceiling height of 3.50 m; supply air temperature of 19 ° C; and enthalpy control. The results of this research also indicate that the use of the enthalpy control has a greater influence on the energy savings compared to the increase of the supply air temperature or the floor to ceiling height.

Page generated in 0.1134 seconds