Spelling suggestions: "subject:"equivalência terapêutica"" "subject:"equivalência terapêutica.o""
21 |
Intercambialidade entre Medicamentos Genéricos: estudo de caso Fluoxetina / Interchangeability between generic drugs: Case study FluoxetinLeite, Flavia Queiroz [UNIFESP] January 2013 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:45:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2013 / Introdução: No ano de 1999 foram regulamentados os medicamentos genericos no Brasil. No desenvolvimento dos medicamentos genericos sao realizados estudos em voluntarios que comprovem a bioequivalencia entre os mesmos, ou seja, dois medicamentos sao considerados bioequivalentes, quando suas biodisponibilidades forem estatisticamente comparaveis. Entretanto, isto nao garante que os medicamentos genericos aprovados sejam intercambiaveis entre si, e apenas, que eles sao intercambiaveis com o seu medicamento referencia. Objetivo: Avaliar a intercambialidade entre os medicamentos genericos contendo cloridrato de fluoxetina, registrados pela Anvisa e comercializados no pais. Metodos: Foram identificados 12 medicamentos genericos comercializados, contendo o principio ativo cloridrato de fluoxetina, na concentracao de 20 mg, na apresentacao em capsulas dura gel, destes, 2 deles foram excluidos por tratar-se de estudos de bioequivalencia repetidos (copias), e um terceiro, foi excluido por nao ter comprovado a equivalencia das variabilidades inter-individuos e intra-individuos, quando comparado aos outros estudos. A avaliacao da intercambialidade entre os medicamentos genericos foi realizada atraves de calculos estatisticos para os parametros de bioequivalencia, area sob a curva de concentracao plasmatica versus tempo (ASC0-t) e concentracao plasmatica maxima observada (Cmax). Foi utilizado o metodo proposto por Chow e Liu para a metanalise dos 9 estudos de bioequivalencia selecionados. Resultados: Todos os 9 estudos tiveram os calculos dos parametros farmacocineticos refeitos, e os intervalos de confianca 90% obtidos para as razoes dos parametros farmacocineticos Cmax e ASC dos produtos teste 1 a 9, em relacao aos seus respectivos referencias, apresentaram-se dentro dos limites estabelecidos pela Anvisa, o que significa que, foi confirmada a bioequivalencia entre cada um desses 9 medicamentos genericos com o seu respectivo referencia. Os intervalos de confianca 90% para o parametro Cmax apresentaram diferencas na velocidade de absorcao entre os produtos: - Teste 2 x Teste 6 (IC de 79,16 a 95,23%) e Teste 2 x Teste 9 (IC de 79,23 a 94,81%). Nestas duas comparacoes os intervalos de confianca extrapolaram os limites de 80% a 125%, dessa forma, de acordo com as legislacoes da Anvisa, estas formulacoes nao sao bioequivalentes entre si, o que inviabilizaria a intercambialidade entre estes medicamentos. Conclusoes: Atraves dos resultados obtidos na metanalise dos estudos de bioequivalencia dos medicamentos genericos comercializados, contendo o principio ativo cloridrato de fluoxetina, podemos concluir que, nem todos os medicamentos genericos disponiveis no mercado sao bioequivalentes entre si, podendo resultar em respostas terapeuticas diferentes nos pacientes / BV UNIFESP: Teses e dissertações
|
22 |
Estudo dos métodos estatísticos na análise da biodisponibilidade relativa/bioequivalência para o registro de medicamentos no Brasil / Study of the statistical methods in the analysis of the biodisponibilidade relativa/bioequivalência for the registration of medications in BrazilPitta, Luciana da Rocha January 2004 (has links)
Made available in DSpace on 2014-09-24T12:58:26Z (GMT). No. of bitstreams: 2
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
172.pdf: 628089 bytes, checksum: 3763e5324edda128696e185d8098c259 (MD5)
Previous issue date: 2004 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / A ANVISA, órgão que regulamenta e controla a liberação dos medicamentos no Brasil, não indica um método estatístico específico para ser utilizado nos estudos de BD relativa/BE. Tendo em vista que existem vários métodos estatísticos possíveis, hipotetizamos aqui que, em determinados casos, poderíamos obter um resultado não bioequivalente com um determinado modelo estatístico e bioequivalente utilizando um outro modelo. Em nosso trabalho, comparamos os resultados dos seguintes métodos estatísticos: Filler, Anderson e Hauck, Shortest, Lehmann (NP), T-test, Westlake, Baseado ANOVA, Hauschke Trabalhamos com 49 estudos de bioequivalência e constatamos que 28 (57%)destes foram bioequivalentes, enquanto 9 (18,4%) se apresentaram bioinequivalentes em todos os métodos utilizados. Nos 12 (24,5%) restantes, obtivemos resultados contraditórios. Analisando o resultado de um determinado método em relação ao da maioria, demonstramos que o Teste t na diferença, Lehmann, Hauschke e o Anderson eHauck foram os que concluíram mais resultados diferentes da maioria dos método sem questão. Já o Teste t e o teste baseado na ANOVA, ambos utilizando a razão das médias, e o método de Westlake, foram os que obtiveram apenas um resultado diferente da maioria dos métodos estatísticos utilizados. Podemos ressaltar que a maior parte dos resultados em bioinequivalência foi em função do parâmetro Cmax com 67,36%. Já em relação ao parâmetro ASC, concluímos bioinequivalência em apenas 1,04% dos métodos. Além disso, obtivemos 31,61% dos resultados acusando não bioequivalência em ambos os parâmetros. / ANVISA, organ that regulates and it controls the liberation of the medicines in Brazil, it doesn't indicate a statistical method specify to be used in the studies of BDrelative/BE. Tends in view that several possible statistical methods exist, we presume that, in certain cases, we could obtain a result no bioequivalente with a certain statistical model and bioequivalente if we use another model. In our work we compared the results of the following statistical methods: Filler, Anderson and Hauck, Shortest, Lehmann (NP), T-test, Westlake, Based ANOVA, Hauschke With the end of our study, where we worked with 49 bioequivalence studies and we verified that 28 (57%) studies were bioequivalentes and 9 (18,4%) they were bioinequivalentes in all of the used methods. In the 12 (24,5%) remaining studies had resulted contradictory. Analyzing the result of a certain method in relation to the result of most of the methods, we demonstrated that the Test t in the difference, Lehmann, Hauschke and Anderson and Hauck were the ones that ended more results different from most of the methods in subject. Already the Test t and the test based on ANOVA, both using the reason of the averages and the method of Westlake, they were the ones that just obtained one result different from most of the used statistical methods. We can stand out although most of the results in bioinequivalence was in function of the parameter Cmax with 67,36%. Already the parameter ASC concluded bioinequivalence in only 1,04% of the methods. Besides, we obtained 31,61% results of no bioequivalence with both parameters.
|
23 |
Validação de formulário de notificação de eventos adversos a plantas medicinais e fitoterápicosCosta, Marília Amaral [UNESP] 16 May 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-05-16Bitstream added on 2014-06-13T18:32:32Z : No. of bitstreams: 1
costa_ma_me_arafcf.pdf: 1204914 bytes, checksum: 4d527a73b978cbb1816136024f90bf1c (MD5) / A utilização de plantas medicinais como forma de tratar doenças é uma prática que ocorre desde os tempos mais antigos. Nos dias atuais, a população idosa traz consigo esta prática e grande parte das pessoas faz uso de plantas medicinais por acreditarem que “por ser natural, não faz mal”. Sabe-se que as plantas medicinais podem levar ao aparecimento de eventos adversos, porém estes são pouco relatados ao profissional da saúde pelo fato do paciente não relacionar o uso da planta medicinal ou medicamento fitoterápico ao evento adverso apresentado. A farmacovigilância relacionada a plantas medicinais, no Brasil, não é totalmente eficaz. A subnotificação de eventos adversos, o não treinamento do profissional de saúde e a não valorização de que plantas medicinais e medicamentos fitoterápicos desencadeiam eventos adversos podem levar ao aparecimento dos mesmos sintomas em outros pacientes. Logo, o presente trabalho visou validar um instrumento de notificação de eventos adversos específico a plantas medicinais e medicamentos fitoterápicos em profissionais de saúde (farmacêuticos, médicos, nutricionistas, enfermeiros e dentistas) através da utilização de dois casos clínicos fictícios, entregues e tempos diferentes, juntamente com uma amostra de planta referente a cada caso clínico e um Guia auxiliar ao preenchimento do formulário no segundo momento. Foi realizada a validação parcial do formulário de notificação, tendo em vista que o entendimento de alguns campos do formulário não foram devidamente preenchidos por falta de compreensão de conceitos ou interpretação dos casos clínicos. Observou-se uma possível não utilização do guia disponível, levando a um preenchimento inadequado ou incompleto da notificação, o que pode acarretar no não entendimento do real evento adverso observado. Todos os itens do... / The use of medicinal plants as a way to treat disease is a practice that occurs from the earliest times. Nowadays, the elderly population carries this practice and most people make use of medicinal plants for believing that as it is natural, will not cause prejudice for their health. It is known that medicinal plants can lead to the onset of adverse events, but these are not reported to health care because the patient does not relate to the use of medicinal plant or herbal medicine to adverse events submitted. Pharmacovigilance related to medicinal plants in Brazil is not fully effective. Underreporting of adverse events, health professionals not trained and not appreciated that medicinal plants and herbal medicines trigger adverse events can lead to the appearance of the same symptoms in other patients. Therefore, this study aimed to validate an instrument for reporting of adverse events specific to medicinal plants and herbal medicines using as volunteer health professionals (pharmacists, physicians, dietitians, nurses, and dentists) using two clinical cases fictitious delivered, at different times, along with a sample of plant for each clinical case and a Guide to help to complete the form on the second time. It was observed that even the Guide was available, it could be not used, which may result in no real understanding of the adverse effects observed. All items on the form were evaluated according to the reliability and completeness of responses, leading to a suggestion of better preparing the notification form and inclusion of auxiliary information in the Guide, to ensure proper notification by the health professional. From the results obtained in this research, the proposed notification form undergoes some modifications to ensure your best fill. The study showed that it is essential to these professional training courses to enhance the... (Complete abstract click electronic access below)
|
24 |
Validação de formulário de notificação de eventos adversos a plantas medicinais e fitoterápicos /Costa, Marília Amaral. January 2013 (has links)
Orientador: Patrícia de Carvalho Mastroianni / Coorientador: Luis Vitor Silva do sacramento / Banca: Eliana Rodrigues / Banca: Marisa Veiga Capela / Resumo: A utilização de plantas medicinais como forma de tratar doenças é uma prática que ocorre desde os tempos mais antigos. Nos dias atuais, a população idosa traz consigo esta prática e grande parte das pessoas faz uso de plantas medicinais por acreditarem que "por ser natural, não faz mal". Sabe-se que as plantas medicinais podem levar ao aparecimento de eventos adversos, porém estes são pouco relatados ao profissional da saúde pelo fato do paciente não relacionar o uso da planta medicinal ou medicamento fitoterápico ao evento adverso apresentado. A farmacovigilância relacionada a plantas medicinais, no Brasil, não é totalmente eficaz. A subnotificação de eventos adversos, o não treinamento do profissional de saúde e a não valorização de que plantas medicinais e medicamentos fitoterápicos desencadeiam eventos adversos podem levar ao aparecimento dos mesmos sintomas em outros pacientes. Logo, o presente trabalho visou validar um instrumento de notificação de eventos adversos específico a plantas medicinais e medicamentos fitoterápicos em profissionais de saúde (farmacêuticos, médicos, nutricionistas, enfermeiros e dentistas) através da utilização de dois casos clínicos fictícios, entregues e tempos diferentes, juntamente com uma amostra de planta referente a cada caso clínico e um Guia auxiliar ao preenchimento do formulário no segundo momento. Foi realizada a validação parcial do formulário de notificação, tendo em vista que o entendimento de alguns campos do formulário não foram devidamente preenchidos por falta de compreensão de conceitos ou interpretação dos casos clínicos. Observou-se uma possível não utilização do guia disponível, levando a um preenchimento inadequado ou incompleto da notificação, o que pode acarretar no não entendimento do real evento adverso observado. Todos os itens do... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of medicinal plants as a way to treat disease is a practice that occurs from the earliest times. Nowadays, the elderly population carries this practice and most people make use of medicinal plants for believing that as it is natural, will not cause prejudice for their health. It is known that medicinal plants can lead to the onset of adverse events, but these are not reported to health care because the patient does not relate to the use of medicinal plant or herbal medicine to adverse events submitted. Pharmacovigilance related to medicinal plants in Brazil is not fully effective. Underreporting of adverse events, health professionals not trained and not appreciated that medicinal plants and herbal medicines trigger adverse events can lead to the appearance of the same symptoms in other patients. Therefore, this study aimed to validate an instrument for reporting of adverse events specific to medicinal plants and herbal medicines using as volunteer health professionals (pharmacists, physicians, dietitians, nurses, and dentists) using two clinical cases fictitious delivered, at different times, along with a sample of plant for each clinical case and a Guide to help to complete the form on the second time. It was observed that even the Guide was available, it could be not used, which may result in no real understanding of the adverse effects observed. All items on the form were evaluated according to the reliability and completeness of responses, leading to a suggestion of better preparing the notification form and inclusion of auxiliary information in the Guide, to ensure proper notification by the health professional. From the results obtained in this research, the proposed notification form undergoes some modifications to ensure your best fill. The study showed that it is essential to these professional training courses to enhance the... (Complete abstract click electronic access below) / Mestre
|
25 |
Estudo de biodisponibilidade relativa entre duas formulações de metotrexato em plasma humano utilizando cromatografia liquida acoplada a espetrometria de massas em serie / Liquid chromatography-mass spectrometry method for determination of methotrexate in human plasmaPioto, Ligia Rodrigues 15 January 2007 (has links)
Orientador: Jose Luiz Donato / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-10T07:16:04Z (GMT). No. of bitstreams: 1
Pioto_LigiaRodrigues_D.pdf: 680751 bytes, checksum: 6d472989ce55c9ad510ce3f7fffb6630 (MD5)
Previous issue date: 2007 / Resumo: Foi desenvolvido um métdo rápido, sensível e específico para determinação de metotrexato em plasma sanguíneo humano por cromatografia líquida acoplada a espectrometria de massas em série usando folinato de cálcio como padrão interno. O metotrexato foi extraído do plasma humano, utilizando-se precipitação de proteínas plasmáticas com acetonitrila como eluente.O método tem uma corrida cromatográfica de 3,5 minutos usando uma coluna analítica C18 (4,6 mm x 75 mm d.i, 3.5 µm tamanho das partículas) e a curva de calibração foi linear de 10 a 300 ng.mL-1.A recuperação do método de extração foi, em média, de 76,5% e o limite de quantificação para o metotrexato foi de 10 ng.mL-1 / Abstract: A rapid, sensitive and specific method was developed for the determination and quantitation of methotrexate, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using calcium folinate as internal standard. Methotrexate was extracted from 0,2 mL human plasma by protein precipitation procedure using acetonitrile as eluent. The method included a chromatographic run of 3,5 minutes using a C18 analytical column (4,6 mm x 75 mm i.d., 3.5 µm particle size) and the linear calibration curve over the range from 10 to 300 ng mL-1. Recoveries were greater than 76.5% and the limit of uantitation of methotrexate was 10 ng mL-1 / Doutorado / Mestre em Farmacologia
|
26 |
Planejamento e avaliação de estudos de biodisponibilidade relativa para medicamentos genericos / Planning and evaluation of relative bioavailability studies for generic drugsMendes, Gustavo Duarte 04 November 2007 (has links)
Orientador: Gilberto De Nucci / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T21:47:39Z (GMT). No. of bitstreams: 1
Mendes_GustavoDuarte_D.pdf: 4560955 bytes, checksum: 46a77f9c7609d08ca99e21f6b7003536 (MD5)
Previous issue date: 2007 / Resumo: Os estudos de biodisponibilidade/bioequivalência foram iniciados no Brasil em 1989 e o processo de regulamentação do setor foi iniciado em 1999 pela promulgação da lei de genéricos. A regulamentação do setor tem propiciado grande aumento na qualidade de fabricação dos medicamentos similares e genéricos, já que a realização de estudos de biodisponibilidade visa, em última análise, comprovar a eficácia terapêutica destes medicamentos. O presente trabalho tem por objetivo o planejamento e avaliação de estudos de biodisponibilidade/bioequivalência e desenvolvimento de metodologia analítica para quantificação das amostras para os fármacos avaliados (citalopram, ramipril e gliclazida). Adicionalmente, as avaliações dos estudos visam o aprimoramento dos protocolos de estudos futuros para novas formulações destes fármacos e a menor exposição possível do voluntário, respeitando os referenciais básicos de bioética. Os parâmetros considerados para o desenvolvimento dos protocolos clínicos foram: número adequado de voluntários, sexo dos voluntários, tempos de coleta para caracterização do perfil farmacocinético, forma farmacêutica, intervalo entre as administrações, condição de administração (alimentação/jejum) e metodologia analítica a ser utilizada para o doseamento das amostras.
Resultados: 1) Para citalopram, o coeficiente de variabilidade intra-sujeito para Cmax e ASClast foram14.09 e 8.38, respectivamente. 2) Para ramipril, o coeficiente de variabilidade intra-sujeito para Cmax e ASClast foram menor para o metabólito ativo, como esperado para em estudos de bioequivalência, confirmando que os fármacos na forma inalterada são mais discriminativos para estabelecer bioequivalência. 3) Para gliclazida, a média geométrica e intervalo de confiança de 90% para a razão Gliclazida/Diamicron (Irelanda) foram 588.68% (90% CI= 491.16, 705.58%) para ASClast e 1395.77% (90% CI= 1116.62, 1744.72%) para Cmax. A média geométrica e intervalo de confiança de 90% para a razão Gliclazide/Diamicron (Brasil) foram 249.16% (90% CI= 207.96, 298.54%) para ASClast, e 188.04% (90% CI= 151.72, 233.05%) para Cmax. A média geométrica e intervalo de confiança de 90% para a razão Diamicron(Brazil)/Diamicron (Irelanda) foram 236.26% (90% CI= 197.12, 283.17%) para ASClast e 225.21% (90% CI= 175.25, 289.42%) para Cmax.
Conclusões: 1) As metodologias analíticas desenvolvidas para ramipril, citalopram e gliclazida foram adequadas para rotinas com grande quantidade de amostras para doseamento, como estudos farmacocinéticos ou de biodisponibilidade. 2) A formulação teste de citalopram é bioequivalente a formulação de referência para velocidade e extensão de absorção. Estudos futuros de citalopram podem ser realizados com menor número (14-16) de voluntários, baseado no baixo coeficiente de variabilidade intra-sujeito. 3) A formulação teste de ramipril também é bioequivalente à formulação de referência para velocidade e extensão de absorção. Estudos futuros de ramipril devem ser realizados pela quantificação do fármaco na sua forma inalterada e coletas de amostras até 10 horas após a administração. 4) Com relação ao estudo de gliclazida, as diferenças entre as formulações teste e referências não demonstram bioequivalência. Interessante, é o fato que as formulações de referência [Diamicron Brasil e Irlanda] não são bioequivalentes entre si, indicando diferenças significativas nas formulações de referência produzidas em países diferentes (neste caso particular, Irlanda e Brasil) / Abstract: Bioavailability/bioequivalence studies began in Brazil in 1989 and the regulation of this sector began in 1999 with the promulgation of laws regulating generic medications. The regulations of this sector have been fostering a growth in the production quality of generic and similar medications, since the performance of Bioavailability studies aims, at the end, to prove the efficacy of these medicatons. This work aims at the planning and evaluation of bioavailability/bioequivalence studies, the development of analytical methods for quantifying samples of evaluated pharmaceuticals (citalopram, ramipril and gliclazide). Additionally, this evaluation aims to improve protocols for future studies for new formulations as well as to decrease volunteer exposure to a minimum, respecting basic bioethical principles. The parameters considered for developing the clinical protocols were: the adequate number of volunteers, volunteer gender, sampling times for characterizing the pharmacokinetic profile, pharmaceutical form, interval between administrations, administration conditions such as fasting and non fasting, and the analytical method used for determining sample dosage. Three bioequivalence studies (citalopram, ramipril, gliclazide) were used to demonstrate the parameters considered in developing the clinical protocols. Results: 1) For citalopram, the intra subject CV% for Cmax and AUClast were14.09 and 8.38, respectively. 2) For ramipril, the intra-subject variation (% CV) for both Cmax and AUCs ratios were lower for the active metabolite, as expected in bioequivalence studies, confirming that the parent compounds are more discriminative to establish bioequivalence. 3) For gliclazide, the geometric mean and 90% confidence intervals (CI) for the Gliclazide/Diamicron (Ireland) ratio were 588.68% (90% CI= 491.16, 705.58%) for AUClast and 1395.77% (90% CI= 1116.62, 1744.72%) for Cmax. The geometric mean and 90% confidence intervals (CI) for the Gliclazide/Diamicron (Brazil) ratio were 249.16% (90% CI= 207.96, 298.54%) for AUClast, and 188.04% (90% CI= 151.72, 233.05%) for Cmax. The geometric mean and 90% confidence intervals (CI) for the Diamicron(Brazil)/Diamicron (Ireland) ratio were 236.26% (90% CI= 197.12, 283.17%) for AUClast and 225.21% (90% CI= 175.25, 289.42%) for Cmax. Conclusion: 1) The analytical method developed for ramipril, citalopram and gliclazide were adequate for routines with large quantities of samples, such as pharmacokinetic or bioavailability studies. 2) The citalopram test formulation was bioequivalent to the reference formulation regarding the rate and extent of absorption. Future studies of citalopram can be performed with a lower number of volunteers (14-16), based on the low intra subject CV. 3) Test formulations of ramipril were also bioequivalent to the reference formulation regarding the rate and extent of absorption. Future studies of ramipril need to be performed to quantify the pharmaceutical in its unaltered form alone by collecting samples up until ten 10 hours after administration. 4) Gliclazide was not bioequivalent to its reference formulations. Interestingly, the reference formulations [Diamicron Brazil and Ireland] were not bioequivalent with each other, indicating significant differences in reference formulations produced in different countries / Doutorado / Clinica Medica / Doutor em Clínica Médica
|
27 |
Biodisponibilidade comparativa de duas formulações de losartan em voluntarios humanos sadios apos administração de dose unica / Comparative bioavailability of two losartan formulations in healthy human volunteers after a single dose administrationSilva, Renato Medeiros 14 August 2018 (has links)
Orientador: Gilberto de Nucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-14T20:52:52Z (GMT). No. of bitstreams: 1
Silva_RenatoMedeiros_M.pdf: 5432076 bytes, checksum: abb10d1ceb928cd0c634eae336f2d154 (MD5)
Previous issue date: 2009 / Resumo: Esta dissertação irá focar na avaliação da bioequivalência de duas formulações do Losartan Potássico (50mg) comprimidos de liberação imediata (Losartan do Laboratório Cristália Ltda, Brasil, como formulação teste e Cozaar® da Merck Sharp & Dohme Farmacêutica Brasil como formulação referência). A bioequivalência foi conduzida usando um estudo aberto, randomizado, cruzado de duas fases com um intervalo de washout de 1 semana. Foram utilizados 25 voluntários de ambos os sexos. As amostras de plasma foram obtidas sobre um período de 24 horas. As concentrações plasmáticas do Losartan e seu metabolito ativo Losartan Ácido foram determinadas por cromatografia líquida de fase reversa acoplada à espectrometria de massa (LC-MS-MS), com modo de ionização electrospray negativo usando o monitoramento de múltiplas reações (MRM). Das curvas de concentração plasmática versus o tempo para Losartan e Losartan Ácido, os seguintes parâmetros farmacocinéticos foram obtidos: AUClast, AUCo-inf e Cmax. Resultados: A média geométrica e o respectivo intervalo de confiança de 90% Losartan / Cozaar® para o Losartan foram: 92,9% (82,2 - 105,0%) para Cmax,, 99,0% (92,5 -105,9%) para AUClast, e 99,1% (92,7 - 105,8%) para AUC0-M,. Alem disso, a média geométrica e a respectivo intervalo de confiança de 90% Losartan / Cozaar® para o Losartan Ácido foram: 98,5% (91,5 - 106,0%) para Cmax, 97,9% (93,3 - 102,7%) para AUClast, e 98,1% (93,5 - 102,9%) para AUC0-M Utilizando um IC de 90% para AUClast, AUC0-M e Cmax dentro do intervalo de 80125% proposto pelo FDA (USA). As duas formulações foram bioequivalentes para a taxa e velocidade de absorção, para o medicamento Losartan 50 mg comprimidos de liberação imediata. Além disso, não foi apresentada nenhuma diferença significante entre a determinação de bioequivalência entre o Losartan e o Losartan Ácido, portanto, futuras bioequivalências, deste medicamento, poderão ser realizadas apenas para o Losartan, sendo assim mais discriminatório / Abstract: This dissertation focus in the evaluation of the bioavailability of two formulations of potassium losartan immediate release tablet 50mg (Losartan from Laboratórios Cristália Ltd., Brazil, as a test formulation and Cozaar® from Merck Sharp & Dohme Farmacêutica Ltd., Brazil as a reference formulation). The bioequivalence study was conducted using an open, randomized, in a two-period crossover design and a one week washout period. Plasma samples were obtained over a 24hour interval. The concentrations of losartan and its active metabolite losartan acid were analyzed by combined reversed phase liquid chromatography and tandem mass spectrometry (LC-MS-MS) with negative ion electrospray ionization using a selected ion monitoring method. From the losartan and losartan acid plasma concentrations vs. time curves the following pharmacokinetic parameters were obtained: AUClast, AUC0-inf and Cmax. Results: the geometric mean and respective 90% confidence interval (CI) of Losartan / Cozaar® losartan percent ratios were 92.9% (82.2 - 105.0%) for Cmax, 99.0 (92.5 - 105.9%) for AUClast, and 99.1% (92.7 - 105.8%) for AUC0-M. Furthermore, the geometric mean and respective 90% confidence interval (CI) of Losartan / Cozaar® losartan acid percent ratios were 98.5% (91.5 - 106.0%) for Cmax, 97.9 (93.3 - 102.7%) for AUClast, and 98.1% (93.6 -102.9%) for AUC0 -inf. Since the 90% CI for Cmax, AUClast and AUC0-M were within the 80-125% interval proposed by the US-Food and Drug Administration. It was concluded that the potassium losartan immediate release 50 mg tablet was bioequivalent to the Cozaar® immediate release 50 mg tablet, according to both the rate and extent of absorption. Since there were no significant differences in the bioequivalence assessed by either losartan or losartan acid, future bioequivalence studies on losartan may be performed by quantifying losartan alone as the parent compound is more discriminative / Mestrado / Mestre em Farmacologia
|
28 |
Estudo de farmacocinetica comparativa de uma formulação de amlodipina + maleato de enalapril versus uma formulação de amlodipina e versus uma formulação de maleato de enalapril em voluntarios sadios de ambos os sexos / Comparative pharmacokinetics study of a formulation of amlodipine + enalapril versus an enalapril maleate formulation in healthy volunteers of both gendersSverdloff, Carlos Eduardo 15 August 2018 (has links)
Orientador: Gilberto de Nucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T13:17:16Z (GMT). No. of bitstreams: 1
Sverdloff_CarlosEduardo_M.pdf: 4673925 bytes, checksum: f893198475aafb4eeacafebdb4936962 (MD5)
Previous issue date: 2009 / Resumo: Introdução: Com base em evidências de estudos mostrando que em cerca de 2/3 dos casos de hipertensão a monoterapia não é suficiente para atingir as reduções pressóricos previstas, e diante da necessidade de controle mais rigoroso dos níveis pressóricos, há clara tendência atual para a introdução precoce de terapêutica combinada de anti-hipertensivos como primeira medida farmacológica. Tais associações de anti-hipertensivos podem ser feitas por meio de fármacos em separado ou por associações em doses fixas. Entre as associações eficazes conhecidas tem-se o caso de inibidores de enzima conversora de angiotensina e bloqueadores dos canais de cácio; um exemplo desta associação é a de amlodipina e enalapril. Objetivo: O presente estudo analisa a farmacocinéica comparativa de um produto contendo Amlodipina e outro contendo enalapril com um produto contendo a combinação dos dois princípios ativos. O produto testado foi Sinergen® (5mg/20mg) dos Laboratórios Biosintética Ltda. O produto referência para o Amlodipina foi o Norvasc®, comprimido de 5 mg, produzido pelo Laboratório Pfizer Ltda e o produto referência para o Enalapril foi o Renitec®, comprimido de 20 mg, produzido pela Merck Sharp Dohme. Materiais e métodos: 36 voluntários saudáveis de ambos os sexos foram internados em três oportunidades, nas quais receberam a associação de amlodipina e enalapril, amlodipina individualmente e enalapril individualmente. Coletas a intervalos regulares foram durante 144 horas para amlodipina e durante 24 horas para enlapril. As concentrações de Amilodipina, Enalapril e Enalaprilato foram medidas através de método analítico apropriado e validado por espectrofotometria de massas (LC-MS MS). A análise estatística dos resultados foi realizada mediante ANOVA. Resultados: As razões teste/referência das formulações para os parâmetros Cmax e ASC em estudo estiveram dentro do intervalo de 80-125%. Conclusão: Após análise estatística correspondente por ANOVA, chegou-se à conclusão que a formulação teste Sinergen é bioequivalente no que diz respeito às formulações referência Renitec (Enalapril) e Novarsec (amlodipina), já que todas as relações T/R para Cmax, AUC 0-inf e AUC 0-last das formulações estavam compreendidas no intervalo 80%-125%, determinado por ANVISA como condição de bioequivalência / Abstract: Introduction: Based on evidence of studies showing that in 2/3 of the cases of hypertension monotherapy is not enough to reach pressure reduction and facing the necessity of a more rigorous control, there is a clear current trend to the early introduction of a combined therapy of anti-hypertensive drugs as first pharmacological measure. These associations of anti-hypertensives can be made through separate products or through associations in fixed doses. Among the known efficient associations there is the case of angiotensin converting enzyme (ACE) inhibitors and calcium channels blockers; an example of these associations is the one of amlodipine and enalapril. Objective: This study analyses the comparative pharmacokinetics of a product containing amlodipine, a second one containing enalapril against a product containing the two active principles. The product test, Sinergenè (5mg/20mg) was manufactured by Laborat?ios Biosint?ica Ltda. The reference product for Amlodipina was Norvascè, 5 mg tablet, manufactured by Laborat?io Pfizer Ltda and the reference product for Enalapril was Renitecè, 20 mg tablet, manufactured by Merck Sharp Dohme. Materials and methods: 36 healthy volunteers of both genders were confined in three periods during which they received the association of amlodipina and enalapril, amlodipine individually and enalapril individually. Collects at regular intervals during 144 hours for amlodipine and 24 hours for enalapril were measured through a proper validated analytical method. The plasmatic concentrations of Amlodipine, Enalapril and enalaprilate were measured by a proper validated analytical method of mass spectrometry (LC-MS-MS). The statistical analysis was performed by ANOVA. Results: The relation of test and reference of the formulations for the parameters Cmax and AUC were within 80-125%. Conclusion: After statistical analysis by ANOVA, we reached the conclusion that the test formulation, Sinergen, is bioequivalent to the reference formulations Renitec (Enalapril) and Novarsec (amlodipina), since all the T/R relations for Cmax, AUC 0-inf and AUC 0-last of the formulations were within 80%-125% interval determined by ANVISA as condition of bioequivalence / Mestrado / Mestre em Farmacologia
|
29 |
Comparação da bioequivalência de duas formulações da risperidona / Comparison of bioequivalence between two formulations of risperidoneKarisa Cristina Rodrigues Belotto 10 May 2010 (has links)
Desde 1964, o Brasil tem lançado programas de políticas públicas para melhorar o acesso da população aos medicamentos considerados essenciais. Em 1999, com a criação da Agência Nacional de Vigilância Sanitária e a introdução dos medicamentos genéricos no mercado brasileiro, o Brasil passou a ter três classes de medicamentos disponíveis no mercado farmacêutico: referência, similar e genérico. O objetivo deste estudo foi avaliar a bioequivalência e intercambialidade entre dois antipsicóticos (referência e similar) utilizados pelo Instituto de Psiquiatria do Hospital das Clínicas da Universidade de São Paulo, contendo 2 mg de risperidona. Foi desenvolvido e validado um método analítico que emprega a cromatografia líquida de alta eficiência acoplada à espectrometria de massas para a determinação da risperidona (RSP) e seu principal metabólito a 9-hidroxirisperidona (9OH-RSP) em plasma. Para se avaliar a bioequivalência entre os medicamentos foram recrutados 22 voluntários sadios, os quais participaram do estudo clínico conduzido de forma cruzada e aleatória. As coletas sanguíneas para o ensaio de bioequivalência foram realizadas em tubos heparinizados (5 mL) e os tempos de coleta foram 0 (antes da medicação); 0,25; 0,5; 1; 1,5; 3; 5; 8; 12; 24; 48; 72; 96 e 120 horas após a administração da medicação. A determinação da bioequivalência entre os dois medicamentos deu-se através da comparação dos parâmetros farmacocinéticos: concentração plasmática máxima (Cmax), tempo para atingir a concentração plasmática máxima (Tmax) e área sobre a curva de decaimento plasmático (ASCT). Os resultados obtidos foram submetidos à análise de variância (ANOVA) e foi adotado o intervalo de confiança de 90% (IC 90%). Os valores médios para Cmax, Tmax e ASCT para RSP para os medicamentos referência e teste foram 16,02 ng/mL; 1,5 h e 348,94 ng.h/mL e 12,65 ng/mL; 1,5 h e 286,03 ng.h/mL, respectivamente. Já os valores médios para Cmax, Tmax e ASCT para 9OH-RSP para os medicamentos referência e teste foram 21,00 ng/mL; 5,0 h e 821,40 ng.h/mL e 17,85 ng/mL; 5,0 h e 632,92 ng.h/mL. Os valores de IC 90% para Cmax e ASCT para RSP para os medicamentos referência e teste foram 74 a 82% e 76 a 85%, respectivamente, e os valores de IC 90% para os mesmos parâmetros para 9OH-RSP foram 83 a 87% e 75 a 78%, respectivamente. Os resultados demonstraram diferenças significativas entre os medicamentos testados, o que permite concluir que os mesmos não são bioequivalentes e, portanto, não podem ser intercambiáveis / Brazil has launched programmes of public policies aiming to improve essential medicines access for the population since 1964. It was created in 1999 the National Agency for Sanitary Vigilance, which introduced the generic medicines in the Brazilian market, which already had the reference and the pharmaceutical equivalent ones. The objective of this study was to evaluate the bioequivalence and interchangeability between two antipsychotics (reference and pharmaceutical equivalent) used by the Institute of Psychiatry, Hospital of the Universidade de São Paulo, containing 2 mg of risperidone. It was developed and validated a high-performance liquid chromatography coupled to mass spectrometry method for the determination in plasma of risperidone (RSP) and its main metabolite, 9- hydroxy-risperidone (9OH-RSP). To assess bioequivalence between the medicines it was recruited 22 healthy volunteers, which took part in a clinical cross and random studies. The blood collections were performed on heparinizades tubes (5 ml) and runtimes collections were 0 (before medication); 0.25; 0.5; 1; 1.5; 3; 5; 8; 12; 24; 48; 72; 96 and 120 hours after the administration of medication. The determination of bioequivalence between the two drugs was achieved by a comparison of the following pharmacokinetic parameters: plasma concentration (Cmax), time to achieve Cmax (Tmax), and area under the plasma concentration-time curve (AUCT). Results were subjected to analysis of variance (ANOVA), adopting a confidence interval CI 90%. The average values for Cmax, Tmax and AUCT for RSP were 16.02 ng/ml, 1.5 h and 348.94 ng.h/ml for reference medicines and 12.65 ng/ml, 1.5 h and 286.03 ng.h/ml for testing ones. The average values for Cmax, Tmax and AUCT for 9OH-RSP were 21.00 ng/ml, 5.0 h and 821.40 ng.h/ml for reference medicines and 17.85 ng/ml, 5.0 h and 632.92 ng.h/ml for testing ones. CI 90% for Cmax and AUC (RSP) were 74-82% and 76-85%, respectively. The CI 90% for the same parameters for 9OH-RSP was 83-87% for reference medicines and 75-78% for testing ones. There was significant difference between the products tested, thus one can conclude they are not bioequivalents, therefore cannot be interchanged
|
30 |
Estudo de bioequivalencia entre duas formulações contendo 2 mg de acetato de ciproterona e 0,035 mg de etinilestradiol em voluntarias sadias atraves de cromatografia liquida acoplada a espectrometria de massas / Bioequivalence study of two formulations with 2 mg of cyproterone acetate and 0,35 mg ethynilestradiol in healthy volunteers by high-performance liquid coupled to mass spectrometryMazuqueli, Ana Cristina 12 August 2018 (has links)
Orientador: Ronilson Agnaldo Moreno / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T08:52:50Z (GMT). No. of bitstreams: 1
Mazuqueli_AnaCristina_M.pdf: 7140095 bytes, checksum: c193ad443d7fe35cf3c6d7b25f3175e8 (MD5)
Previous issue date: 2008 / Resumo: O objetivo deste estudo foi avaliar a bioequivalência de duas formulações de acetato de ciproterona e etinilestradiol em drágea vs comprimido (Selene® comprimidos, Laboratório Eurofarma Ltda., formulação Teste e Diane® 35, Schering do Brasil, como Referência) após administração oral em 48 voluntárias adultas sadias. O estudo foi do tipo aberto, randomizado com duas fases, em que as voluntárias receberam uma dose única de acetato de ciproterona 2mg e etinilestradiol 0,035mg . As amostras de plasma foram obtidas em um período total de 240h. As concentrações plasmáticas de acetato de ciproterona e etinilestradiol foram analisadas por um método baseado na cromatografia líquida acoplada ao espectrômetro de massa usando como fonte de ionização photospray ( LC-MS/MS ) utilizando finasterida como padrão interno do acetato de ciproterona e 17-a-etinilestradiol-D4 como padrão interno do etinilestradiol. A concentração plasmática do acetato de ciproterona não teve diferença significante após a administração de ambas as formulações (formulação teste e referência do Diane®35). A média geométrica da razão entre o medicamento teste e referência com 90% IC, foi 90,66% (84,39% - 97,40% ) para Cmax, 96,20% (90,45% - 102,33%) para ASC0-240 e 95,86% (89,81% - 102,31%) para ASC0-inf. Já para o Etinilestradiol a média geométrica da razão entre o medicamento teste e referência com 90% IC, foi de 109,92% (IC 90% = 102,67% - 117,69% ) para Cmax, 90,63% (83,75% - 98,08%) para ASC0-120 e 83,85% (69,98% - 100,47%) para ASC0-inf. Diante dos resultados encontrados de Cmax e ASC0-t e estando dentro do intervalo de confiança entre 80% e 125% proposto pela Agência Nacional de Vigilância Sanitária (ANVISA) e pelo Food and Drug Administration (FDA), conclui-se que o Acetato de Ciproterona 2mg e o Etinilestradiol 0.035mg da Eurofarma Laboratórios Ltda. em comprimido é bioequivalente ao Diane®35 da Schering do Brasil, de acordo com sua taxa e extensão de absorção. / Abstract: The aim of this study was to assess the bioequivalence of two cyproterone acetate + ethinylestradiol tablet formulations (Selene® tablet formulation elaborated by Eurofarma Laboratórios Ltda., Brazil, as test formulation, and Diane ® 35 tablet formulation by Schering of Brazil, as reference formulation) after their oral administration to 48 healthy adult females. The study was conducted using an open, randomized two-period crossover design, in which twenty-four healthy volunteers received a single oral dose of cyproterone acetate + ethinylestradiol (2mg + 0.035mg) tablet. Plasma samples were obtained over a 240-hour period. Plasma cyproterone acetate + ethinylestradiol concentrations were analyzed by a method based on liquid chromatography by positive-ion photospray ionization (LC-MS/MS), using finasteride as internal standard of cyproterone acetate and 17-a-ethinyl estradiol-D4 as internal ethinylestradiol standard. The plasma concentration of CYP acetate did not differ significantly after the administration of both formulations (test formulation and the reference Diane®), according to the geometric mean ratio between the test and reference formulations, with 90% CI: 90.66% (84.39% - 97.40% ) for Cmax, 96.20% (90.45% - 102.33%) for ASC0-240 and 95.86% (89.81% - 102.31%) for ASC0-inf. Conversely, the geometric mean ratio between the test and reference formulations for ethinylestradiol, with 90% CI, was 109.92% (CI 90% = 102.67% - 117.69% ) for Cmax, 90.63% (83.75% - 98.08%) for ASC0-120 and 83.85% (69.98% - 100.47%) for ASC0-inf. Considering the results of Cmax and ASC0-t within the confidence interval between 80% and 125% proposed by the Brazilian National Agency for Sanitary Surveillance (ANVISA) and for the US Food and Drug Administration (FDA), it was concluded that the cyproterone acetate 2mg and ethinylestradiol 0.035mg by Eurofarma Laboratórios Ltda. in tablet is bioequivalent to the Diane®35 by Schering of Brazil, according to its absorption and extension rate. / Mestrado / Mestre em Farmacologia
|
Page generated in 0.0507 seconds