• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 170
  • 8
  • Tagged with
  • 179
  • 133
  • 119
  • 84
  • 44
  • 27
  • 21
  • 21
  • 17
  • 17
  • 16
  • 16
  • 16
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Sensibilidade e especificidade de um sistema de classificação de risco para infarto agudo do miocárdio em pacientes com dor torácica / Sensitivity and specificity of a risk classification system for acute myocardial infarction in patients with chest pain

Vilanova, Vanessa Cordeiro 20 July 2018 (has links)
A organização do fluxo de atendimento de emergência é um dos grandes desafios para as instituições de saúde. Os sistemas de classificação de risco auxiliam os enfermeiros na priorização do atendimento dos pacientes com maior risco, que podem ter sua condição de saúde agravada durante a espera. Avaliar o desempenho de um sistema de classificação de risco institucional para pacientes com infarto agudo do miocárdio permite conhecer a sua capacidade para estabelecer adequadamente a prioridade de atendimento. Objetivos: Determinar a sensibilidade e especificidade de um sistema institucional de classificação de risco para infarto agudo do miocárdio em pacientes com dor torácica; verificar associações entre as variáveis sociodemográficas com o desempenho do sistema na priorização desses pacientes. Método: Estudo observacional em um hospital de cardiologia. A estimativa da sensibilidade foi avaliada pela capacidade do sistema em classificar nas categorias de maior prioridade (vermelha e amarela) os pacientes com diagnóstico de infarto agudo do miocárdio. A estimativa da especificidade foi avaliada pela capacidade do sistema em classificar com baixa prioridade (verde e azul) os pacientes sem infarto agudo do miocárdio. O padrão de referência foi o registro médico de infarto agudo do miocárdio. Resultados: A amostra foi constituída por 3.032 eventos de classificação de risco, sendo 1.534 (50,6%) do sexo masculino; idade média de 57,9 (DP 15,1) anos;146 (4,8%) eventos de infarto agudo do miocárdio. A sensibilidade do sistema foi de 73,3% (IC 65,2% - 80,1%) e a especificidade de 61,3% (IC 59,4% - 63,0%). O desempenho do sistema foi pior com o aumento da idade dos pacientes (p<0,001); melhor com prioridades mais elevadas (p<0,001) e na presença de supra desnivelamento de segmento ST (p<0,001). Conclusão: O sistema institucional de classificação de risco teve bom desempenho na avaliação de pacientes com queixa de dor torácica por otimizar o atendimento de pacientes com infarto agudo do miocárdio, embora haja espaço para melhoria de desempenho do sistema considerando o aumento do valor de sensibilidade e identificação dos falsos negativos. / The organization of the flow of emergency care is one of the great challenges for health institutions. Risk classification systems assist nurses in prioritizing the care of patients at higher risk, who may have their health condition aggravated during waiting. Evaluating the performance of an institutional risk classification system for patients with acute myocardial infarction allows to know their capacity to adequately establish the priority of care. Objectives: To determine the sensitivity and specificity of an institutional system of classification of risk for acute myocardial infarction in patients with chest pain; to verify associations between the sociodemographic variables with the performance of the system in the prioritization of these patients. Method: Observational study in a cardiology hospital. Sensitivity estimation was assessed based on the ability of the system to classify patients with a diagnosis of acute myocardial infarction into the highest priority categories (red and yellow). Estimating specificity was assessed based on the ability of the system to classify patients without acute myocardial infarction with low priority (green and blue). The gold standard was the medical record of acute myocardial infarction. Results: The sample consisted of 3,032 risk classification events, of which 1,534 (50.6%) were male; mean age of 57.9 (SD 15.1) years, 146 (4.8%) events of acute myocardial infarction. The sensitivity of the system was 73.3% (CI 65.2% - 80.1%) and the specificity was 61.3% (CI 59.4% - 63.0%). System performance was worse with increasing patient age (p <0.001); with higher priorities (p <0.001) and in the presence of ST-segment elevation (p <0.001). Conclusion: The institutional system of risk classification performed well in the evaluation of patients with chest pain for optimizing the care of patients with acute myocardial infarction, although there is space for improvement of the system performance considering the increase of sensitivity and identification of false negatives.
42

Performance dos métodos visual, radiográfico e baseados em fluorescência na detecção de lesões de cárie: revisões sistemáticas com meta-análises e investigações de fontes de heterogeneidade / Performance of visual, radiographic and fluorescence based methods in detecting carious lesions: systematic reviews, meta-analyses and investigation of sources of heterogeneity

Cóvos, Thais Gimenez 13 May 2016 (has links)
O presente estudo teve como objetivo avaliar a performance dos métodos visual, radiográfico e baseados em fluorescência quanto à detecção de lesões de cárie em dentes permanentes e decíduos, realizar meta-análise com a performance global dos métodos e investigar as possíveis fontes de heterogeneidades. Foram realizadas três revisões distintas relacionadas a cada método diagnóstico. Quatro examinadores avaliaram os trabalhos, sendo pelo menos dois por método. Estes efetuaram a busca e seleção de artigos de modo independente; um pesquisador com experiência em trabalhos de diagnóstico de cárie resolveu os casos de conflito ou dúvida. As bases de dados eletrônicas utilizadas foram MEDLINE, EMBASE e Scopus, visando reduzir o viés de publicação, também foram buscados trabalhos acadêmicos e documentos não publicados, através do OpenSigle e Anais do Congresso ORCA. Após a seleção dos estudos por critérios de inclusão e exclusão bem definidos, os dados foram coletados e anotados, de maneira independente por cada revisor. Foi realizada a avaliação da qualidade metodológica através da ferramenta Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e a análise estatística através do Paired Forest Plot, Summary Receiver Operating Characteristics analysis (SROC), relative diagnostic odds ratio (RDOR), análise de sensibilidade e gráfico de funil, além da investigação e exploração das possíveis fontes de heterogeneidade. Para o método visual, 102 artigos preencheram os critérios de inclusão. Em geral, a análise demonstrou que o método visual teve uma boa acurácia para a detecção de lesões de cárie. Embora estudos laboratoriais e clínicos tenham apresentado acurácias semelhantes, os valores de especificidade obtidos clinicamente foram maiores. Observamos, também, moderada a elevada heterogeneidade e evidência de viés de publicação na maioria dos estudos. Além disso, o uso de sistemas de escores visual resultaram em valores significativamente melhores de acurácia em comparação com estudos que utilizaram os seus próprios critérios. Quanto à relevância clínica dos estudos de acurácia do método visual, 96 estudos foram incluídos. Em geral, a maioria dos estudos falha em considerar alguns aspectos clínicos relevantes: somente 1 estudo incluiu avaliação da atividade das lesões; nenhum estudo considerou o seu prognóstico; 79 estudos não consideraram um desfecho clínico relevante e apenas 1 avaliou um desfecho centrado no paciente. Quanto à qualidade metodológica, a maioria dos estudos presentes apresentou alto risco de viés na seleção da amostra. Quanto ao método radiográfico, 116 artigos foram selecionados. Os métodos radiográficos convencional e digital apresentaram desempenho semelhante, mostrando valores maiores de especificidade comparados aos de sensibilidade, além de maiores valores de AUC no limiar de lesões mais avançadas. Quanto aos métodos baseados em fluorescência, 75 estudos preencheram os critérios de inclusão. Em geral, a análise demonstrou uma tendência a valores de acurácia semelhantes para todos os tipos de dentes, superfícies ou tipos de estudo. Houve uma tendência de melhor desempenho na detecção de lesões de cárie mais avançadas. Observamos, também, moderada a alta heterogeneidade e evidência de viés de publicação. Em conclusão, o método visual de detecção de lesões de cárie tem um bom desempenho geral, mas os estudos deveriam considerar desfechos clínicos relevantes, além da acurácia. Além disso, eles deveriam ser conduzidos com maior qualidade metodológica, principalmente em relação à seleção da amostra. Ainda, a utilização de índices detalhados e validados parece melhorar a acurácia do método. O método radiográfico não apresentou diferença entre os modos de aquisição de imagem (digital ou convencional), demonstrando uma tendência a valores superiores de especificidade e melhor desempenho em lesões avançadas. Quanto aos dispositivos baseados em fluorescência, estes mostraram desempenho global semelhante; no entanto, uma melhor acurácia na detecção de lesões de cárie mais avançadas tem sido observada. / This study aimed to evaluate the performance of visual, radiographic and fluorescence-based methods in the detection of caries lesions in permanent and primary teeth, to perform meta-analysis of the overall performance of the methods and to investigate possible sources of heterogeneity. Three distinct systematic reviews related to each diagnostic method were performed. Four observers evaluated the articles, at least two per method. They performed the search and study selection independently; a researcher with experience in caries diagnostic studies solved the cases of conflict or doubt. Electronic databases used were MEDLINE, EMBASE and Scopus, to reduce publication bias, were also pursued academic papers and unpublished documents through OpenSigle and the Annals of ORCA Congress. After the selection of studies by well-defined inclusion and exclusion criteria, data were collected and recorded, independently by each reviewer. Methodological quality assessment was performed through Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS) and statistical analysis using Paired Forest Plot, Summary Receiver Operating Characteristics analysis (SROC), relative diagnostic odds ratio (RDOR), sensitivity analysis and funnel plot, in addition we explored possible sources of heterogeneity. Regarding the accuracy of visual method, 102 articles met the inclusion criteria. In general, visual analysis showed that the method had a good accuracy in the detection of caries lesions. Although laboratory and clinical studies have shown similar accuracies, clinical studies have obtained higher specificities. We also observed moderate to high heterogeneity and evidence of publication bias in most studies. In addition, the use of visual scoring systems resulted in significantly better accuracy compared to studies using their own criteria. Concerning the clinical relevance of accuracy studies of visual method, 96 studies were included. In general, most studies failed to consider some relevant clinical aspects: only 1 study included assessment of activity of the lesions; no study considered their prognosis; 79 studies did not consider a relevant clinical outcome and only 1 evaluated a patient-centered outcome. With regard to the methodological quality, most of the present studies showed a high risk of bias in the selection of the sample. With concern to the radiographic method, 116 articles were selected. Conventional and digital radiographic methods showed similar performance, showing greater specificity values compared to sensitivity, and higher AUC values at the threshold of more advanced caries lesions. Regarding fluorescence-based methods, 75 studies met the inclusion criteria. In general, the analysis demonstrated that the fluorescence-based method tend to have similar accuracy for all types of teeth, dental surfaces or settings. There was a trend of better performance of fluorescence methods in detecting more advanced caries lesions. We also observed moderate to high heterogeneity and evidenced publication bias. In conclusion, the visual method of detecting caries lesions has a good overall performance, but studies should consider relevant clinical outcomes, as well as accuracy. In addition, they should be conducted with greater methodological quality, especially in relation to sample selection. Still, the use of detailed and validated indices seems to improve the accuracy of the method. Radiographic method showed no difference between the image acquisition modes (digital or conventional), showing a tendency to higher values of specificity and performance in advanced caries lesions. Fluorescence-based devices showed similar overall performance; however, a better accuracy in detecting more advanced caries has been observed.
43

Estrutura de prática e processo adaptativo em aprendizagem motora: efeitos da especificidade da tarefa / Practice schedule and adaptative process in motor learning: effects of task specificity

Barros, João Augusto de Camargo 21 September 2006 (has links)
Recentemente os efeitos de diferentes estruturas de prática na aquisição de hablidades motoras têm sido investigados sob um modelo de não-equilíbrio de aprendizagem motora denominado de Processo Adaptativo. Os achados dessas investigações têm se mostrado divergentes e, no presente trabalho, foram especulados em relação à especificidade da tarefa. A pergunta que se fez foi: os efeitos das práticas constante, aleatória, constante-aleatória e aleatória-constante na aquisição de habilidades motoras seriam específicos à tarefa? Sendo assim, esse trabalho teve como objetivo investigar os efeitos de diferentes estruturas de prática na aquisição de habilidades motoras em função da especificidade da tarefa. Foram realizados três experimentos nos quais as exigências de aprendizagem e a variabilidade de prática foram em termos de controle temporal, de força e espacial, respectivamente, experimentos 1, 2 e 3. Os três experimentos envolveram um delineamento com quatro grupos de prática (constante, aleatória, constante-eleatória e aleatória-contante) e de duas fases (estabilização e adaptação). Os participantes de cada experimento foram 60 crianças com idade média de 11 anos. Os resultados permitiram a conclusão de que houve complementaridade de especificidade/generalidade da tarefa nos efeitos da estruturação da prática no processo adaptativo em aprendizagem motora / Recently the effects of practice schedules on the acquisition of motor skills have been investigated under a non-equilibrium model for motor learning known as Adaptive Process. The findings of these investigations have been divergent, and on this dissertation they are speculated on the basis of task specificity. The question asked was: would the effects of constant, random, constant-random and random-constant practice schedules on motor skills acquisition be specific to the task? Thus, the purpouse of this study was to investigate the effects of different practice schedules on the acquisition of motor skills as a function of task specificity. This matter was investigated in three experiments in wich the learning demands and practice variability were in terms of time, force and spatial control, respectively, experiments 1, 2 and 3. The experimental design of the three experiments involved four practice groups (constant, random, constant-random, and random-constant) and two phases (stabilization and adaptation). Sixty children, with mean age of 11 years, participated of each experiment. The results suggest that there is a complementarity of specificity and generability of the effects of the different practice schedules on the adaptive process for the different tasks
44

As especificidades do padrão de apego da criança em relação à figura materna e paterna

Schneider, Michele Scheffel 22 August 2008 (has links)
Made available in DSpace on 2015-03-04T20:04:55Z (GMT). No. of bitstreams: 0 Previous issue date: 22 / Nenhuma / Esta dissertação apresenta uma pesquisa qualitativa que investigou a especificidade do padrão de apego de crianças na relação com seus cuidadores principais, em especial mãe e pai. O referencial teórico de base foi a teoria do apego, desde os conceitos iniciais de Bowlby até as novas perspectivas conceituais, sustentadas pelos pesquisadores que seguem estudando tal temática na atualidade. Os objetivos do estudo foram identificar qual o padrão de apego da criança em relação a suas figuras parentais, avaliar a existência de uma especificidade do padrão de apego em relação à mãe e ao pai e descrever as características familiares associadas ao apego seguro e/ou inseguro. Os resultados encontrados apontam que a qualidade de cada relação emocionalmente significativa é única e um padrão de apego predominantemente seguro pode conter aspectos inseguros e vice-versa. A estabilidade das relações familiares, uma favorável rede de apoio e social, bem como a demarcação de papéis entre pais e filhos foram as principais cara / This dissertation presents a qualitative research about the specificity of the attachment pattern between children and his main caregiver, specially father and mother. The theory reference base was the attachment theory, since Bowlby’s concepts untill the new conceptual perspectives. The goals of this research were identify the children attachment pattern characteristics related to the parents, evaluate the existence of specificity in the attachment pattern related to father and to mother and describe the families characteristics associated to secure attachment and/or insecure. The results indicate that the quality of each significant emotional relationship is unique and a predominant secure attachment pattern can have insecure aspects and vice-versa. The stability of family relationships, a favorable social network support, as well the definition of the roles of children and parents were the main characteristics related to the secure attachment pattern. The insecure attachment pattern is related to sickness
45

Avaliação da punção aspirativa por agulha fina (PAAF) em cavidade oral e região de cabeça e pescoço em diferentes técnicas de coloração / Evaluation of Fine Needle Aspiration Biopsy (FNAB) in oral cavity and head and neck region with different techniques stains

Ana Paula Candido dos Santos 22 August 2014 (has links)
O presente estudo teve como objetivo avaliar a Punção Aspirativa por Agulha Fina (PAAF) em diferentes técnicas de coloração, em lesões nodulares de cavidade oral e região de cabeça e pescoço, quanto a sua sensibilidade, especificidade e acurácia, nas colorações de Panótico, Papanicolau e Hematoxilina-Eosina . Foram selecionados 46 pacientes consecutivamente que procuraram a Clínica da Disciplina de Estomatologia Clínica da FOUSP, portadores de lesões nodulares em cavidade oral e região de cabeça e pescoço. Como critérios de inclusão foram selecionados pacientes de ambos os sexos, todas as etnias, acima dos 5 anos de idade, sem restrição de comorbidades e que foram realizadas PAAF com confirmação diagnóstica pela biópsia. Como critérios de exclusão da pesquisa estão os pacientes abaixo dos 5 anos de idade e pacientes que foram somente submetidos a PAAF sem confirmação diagnóstica pela biópsia. O material obtido pela PAAF foi enviado em 6 lâminas diferentes, corados pelo método de Panótico, Papanicolau e Hematoxilina-Eosina a um mesmo patologista apenas com o diagnóstico clínico. Após a emissão do laudo da PAAF, o laudo do anátomo patológico era emitido, servindo como padrão ouro. Após os cálculos, o resultado da sensibilidade, especificidade e acurácia para o método de coloração com o Panótico foram de 28,6%, 76%, 15,4, respectivamente, para o método de coloração com o Papanicolau foram de 71,4%, 76,7%, 23,3%, respectivamente e para o método de coloração com a Hematoxilina-Eosina foram de 82,1%, 23,3%, 28,6%, respectivamente. Houve diferença estatisticamente significativa na proporção de sensibilidade, especificidade e acurácia entre as diferentes técnicas de coloração (X2 13,27, p=0,01). Podemos concluir que, na metodologia do presente estudo, as colorações de Hematoxilina-Eosina e Papanicolau demonstraram a mesma sensibilidade, para diagnosticar neoplasias malignas. A coloração de Hematoxilina-Eosina demonstrou uma melhor especificidade para diagnosticar neoplasias benignas, quando comparadas com a colorações de Papanicolau e Panótico. A coloração de Hematoxilina-Eosina demonstrou uma melhor acurácia, para dar diagnóstico definitivo, seguida das colorações de Papanicolau e Panótico. / The present study aimed to evaluate the Fine Needle Aspiration Biopsy in different staining techniques in nodular lesions of the oral cavity and head and neck region, as their sensitivity, specificity and accuracy, staining with Panoptic, Papanicolaou and Hematoxylin-Eosin. 46 patients who sought the Clinic of the Discipline of Clinical Stomatology at FOUSP were selected consecutively, with nodular lesions in the oral cavity and head and neck region. Inclusion criteria were patients of both sexes, all ethnicities, above 5 years-old, with no restriction of comorbidities and FNAB performed with confirmation by biopsy. Exclusion criteria were patients under 5 years-old and patients who only underwent FNAB without confirmation by biopsy. The material obtained by FNAB was sent on 6 different slides, stained by the method of Panoptic, Papanicolaou and Hematoxylin-Eosin, to the same pathologist only with the clinical diagnosis. After the final report of FNAB, the biopsy report was issued, serving as gold standard. After the calculations, the results of sensitivity, specificity and accuracy for Panoptic staining were 28.6%, 76% and 15.4%, respectively. The result of sensitivity, specificity and accuracy for Papanicolaou staining were 71,4%, 76.7% and 23.3%, respectively. The result of sensitivity, specificity and accuracy for Hematoxylin-Eosin staining were 82.1%, 23.3%, 28.6%, respectively. There was a statistically significant difference in the proportion of sensitivity, specificity and accuracy between the different staining techniques (X2 13.27, p = 0.01). We can conclude, in the methodology of this study that, Hematoxylin-Eosin and Papanicolaou stains showed the same sensitivity of diagnosing malignant neoplasms. The Hematoxylin-Eosin stain showed a better specificity for diagnosing benign neoplasms, compared with Papanicolaou and Panoptic stains. Hematoxylin-eosin stain showed better accuracy, to give definitive diagnosis, followed by Papanicolaou and Panoptic stains.
46

Estudo da neuroinvasividade do vírus da raiva em amostras de sistema nervoso central de bovinos / Study of the neuroinvesivesse of the rabies virus in samples of central nervous system of cattle

Natalia Helena Frada Centoamore 30 March 2017 (has links)
A raiva é uma encefalomielite aguda causada por um vírus da ordem Mononegavirales, família Rhabdoviridae, gênero Lyssavirus e espécie Rabies virus (RABV). É um vírus RNA de fita simples, senso negativo que acomete todas as espécies de mamíferos. Seu diagnóstico é obtido de modo definitivo por técnicas laboratoriais. A imunofluorescência direta (IFD) é uma prova de triagem rápida, considerada padrão ouro pela OMS e OIE, pois possui alta sensibilidade e especificidade diagnóstica. Esta técnica utiliza como teste confirmatório o isolamento viral em camundongos (IVC) ou em cultura de células (IVCC). Uma vez que o RABV não infecta todas as estruturas do sistema nervoso central (SNC) de modo uniforme, a detecção deste agente pode ter resultados variáveis. Algumas situações exigem o desenvolvimento e implantação de metodologias alternativas, tais como transcrição reversa seguida de reação em cadeia da polimerase (RT-PCR), RT-PCR em tempo real (RT-qPCR) e imunohistoquímica (IHQ), que possuem vantagens e apresentaram resultados bastante promissores. Para tanto, foram utilizadas amostras de SNC[tálamo, córtex, hipocampo, cerebelo, tronco encefálico (bulbo, ponte e mesencéfalo) e medula cervical]de 127 bovinos provenientes da Seção de Diagnóstico da Raiva do Instituto Pasteur, durante o período de março de 2015 a abril de 2016. As diferentes regiões do SNC dos animais foram identificadas e alíquotas foram separadas para a realização das técnicas de identificação viral, totalizando 689 fragmentos. A presença viral foi observada pela IFD e confirmada tanto pelo IVC quanto pelo IVCC. A distribuição do vírus pelas diferentes porções do SNC foi observada pelas técnicas de IFD, IHQ e RT-PCR para detecção do gene N em 40 animais que foram considerados positivos. Os 40 bovinos positivos na IFD confirmaram sua positividade na IHQ e IVC, apresentando concordância de 100% dos resultados. Entretanto houve diferença em relação aos resultados dos isolamentos virais, uma vez que, dos 38 animais positivos que foram submetidosaambas as técnicas, três foram negativos para a presença do RABV no IVCC, indicando uma concordância de 92,1%, (3538) quando comparado ao IVC. Em relação às técnicas moleculares houve diferenças, a RT-PCR apresentou positividade de 100% (4040), enquanto que a RT-qPCR observou-se que 97,5% (39/40) dos bovinos foram positivos. Na IFD, de modo geral, não houve disparidade entre os fragmentos em relação à positividade, porém ocorreu diferença quando se analisou a intensidade de fluorescência entre os fragmentos. Quando comparadas, a IHQ e a IFD apresentaram resultados semelhantes, embora a IHQ tenha apresentado positividade em 100% fragmentos (209209) e a IFD em 99,51% dos fragmentos (205206). Conclui-se, pelos resultados obtidos, diferenças na intensidade da distribuição viral e na concentração de RNA viral nas diferentes porções do SNC (padrões de neuroinvasividade) em bovinos; fato este que poderia interferir nos resultados obtidos no diagnóstico de rotina da raiva. / Rabies is an acute encephalomyelitis caused by a virus belonging to the Mononegavirales order, Rhabdoviridae family, Lyssavirus genus and Rabies virus (RABV) species. It is a single-stranded RNA virus, negative sense that affects all species of mammals. The definitively diagnosis is obtained by laboratory techniques. Direct fluorescent antibody test (dFAT) is a rapid screening, considered the gold standard by WHO and OIE, as it has high diagnostic sensitivity and specificity. However, it´s recommended the mouse inoculation test (MIT) or rabies tissue culture infection test (RTCIT) as a confirmatory test. Once RABV does not infect all central nervous system (CNS) structures uniformly, the detection of this agent may have varying results Some situations require the development and implementation of alternative methods such as RT-PCR, RT-qPCR and immunohistochemistry (IHC), which have advantages and showed very promising results. Therefore, CNS structures [thalamus, cortex, hippocampus, cerebellum, brainstem (medulla, pons and midbrain) and cervical cord] from 127 cattle were selected from the Rabies Diagnostics Section of the Instituto Pasteur during the period March 2015 to April 2016. The different CNS structures were identified and aliquots were separated for carrying out the viral identification techniques, totalizing 689 structures. The viral presence was observed by dFAT and confirmed by both the MIT and the RTCIT. The distribution of the virus by different portions of the CNS was observed by dFAT, IHC and RT-PCR for detection of the N gene in 40 animals considered positive. The 40 positive cattle in the dFAT confirmed their positivity on IHC and MIT, with agreement of 100% of the results. However there was a difference from the viral isolation since the 38 positive animals tested in both techniques, three were negative for the presence of RABV in RTCIT indicating an agreement of 92.1% (35/38) when compared to MIT. The dFAT, in general, showed no disparity among the fragments relative to their positivity, however, a difference was observed when analyzing the fluorescence intensity between the fragments. When compared IHC and dFAT presented similar results, although the IHC has presented a 100% positivity in the fragments (209/209) and 99.51% in dFAT (205/206).Regarding the molecular techniques, RT-PCR showed positivity of 100% (40/40), meanwhile RT-qPCR showed 97,5% (39/40) among the positive animals studied. In conclusion, the results suggest that there is variability in the intensity of virus distribution and in the virus concentration in different parts of the CNS (neuroinvasiveness patterns) in cattle. This fact could affect the results obtained in the diagnosis of rabies routine.
47

Performance dos métodos visual, radiográfico e baseados em fluorescência na detecção de lesões de cárie: revisões sistemáticas com meta-análises e investigações de fontes de heterogeneidade / Performance of visual, radiographic and fluorescence based methods in detecting carious lesions: systematic reviews, meta-analyses and investigation of sources of heterogeneity

Thais Gimenez Cóvos 13 May 2016 (has links)
O presente estudo teve como objetivo avaliar a performance dos métodos visual, radiográfico e baseados em fluorescência quanto à detecção de lesões de cárie em dentes permanentes e decíduos, realizar meta-análise com a performance global dos métodos e investigar as possíveis fontes de heterogeneidades. Foram realizadas três revisões distintas relacionadas a cada método diagnóstico. Quatro examinadores avaliaram os trabalhos, sendo pelo menos dois por método. Estes efetuaram a busca e seleção de artigos de modo independente; um pesquisador com experiência em trabalhos de diagnóstico de cárie resolveu os casos de conflito ou dúvida. As bases de dados eletrônicas utilizadas foram MEDLINE, EMBASE e Scopus, visando reduzir o viés de publicação, também foram buscados trabalhos acadêmicos e documentos não publicados, através do OpenSigle e Anais do Congresso ORCA. Após a seleção dos estudos por critérios de inclusão e exclusão bem definidos, os dados foram coletados e anotados, de maneira independente por cada revisor. Foi realizada a avaliação da qualidade metodológica através da ferramenta Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e a análise estatística através do Paired Forest Plot, Summary Receiver Operating Characteristics analysis (SROC), relative diagnostic odds ratio (RDOR), análise de sensibilidade e gráfico de funil, além da investigação e exploração das possíveis fontes de heterogeneidade. Para o método visual, 102 artigos preencheram os critérios de inclusão. Em geral, a análise demonstrou que o método visual teve uma boa acurácia para a detecção de lesões de cárie. Embora estudos laboratoriais e clínicos tenham apresentado acurácias semelhantes, os valores de especificidade obtidos clinicamente foram maiores. Observamos, também, moderada a elevada heterogeneidade e evidência de viés de publicação na maioria dos estudos. Além disso, o uso de sistemas de escores visual resultaram em valores significativamente melhores de acurácia em comparação com estudos que utilizaram os seus próprios critérios. Quanto à relevância clínica dos estudos de acurácia do método visual, 96 estudos foram incluídos. Em geral, a maioria dos estudos falha em considerar alguns aspectos clínicos relevantes: somente 1 estudo incluiu avaliação da atividade das lesões; nenhum estudo considerou o seu prognóstico; 79 estudos não consideraram um desfecho clínico relevante e apenas 1 avaliou um desfecho centrado no paciente. Quanto à qualidade metodológica, a maioria dos estudos presentes apresentou alto risco de viés na seleção da amostra. Quanto ao método radiográfico, 116 artigos foram selecionados. Os métodos radiográficos convencional e digital apresentaram desempenho semelhante, mostrando valores maiores de especificidade comparados aos de sensibilidade, além de maiores valores de AUC no limiar de lesões mais avançadas. Quanto aos métodos baseados em fluorescência, 75 estudos preencheram os critérios de inclusão. Em geral, a análise demonstrou uma tendência a valores de acurácia semelhantes para todos os tipos de dentes, superfícies ou tipos de estudo. Houve uma tendência de melhor desempenho na detecção de lesões de cárie mais avançadas. Observamos, também, moderada a alta heterogeneidade e evidência de viés de publicação. Em conclusão, o método visual de detecção de lesões de cárie tem um bom desempenho geral, mas os estudos deveriam considerar desfechos clínicos relevantes, além da acurácia. Além disso, eles deveriam ser conduzidos com maior qualidade metodológica, principalmente em relação à seleção da amostra. Ainda, a utilização de índices detalhados e validados parece melhorar a acurácia do método. O método radiográfico não apresentou diferença entre os modos de aquisição de imagem (digital ou convencional), demonstrando uma tendência a valores superiores de especificidade e melhor desempenho em lesões avançadas. Quanto aos dispositivos baseados em fluorescência, estes mostraram desempenho global semelhante; no entanto, uma melhor acurácia na detecção de lesões de cárie mais avançadas tem sido observada. / This study aimed to evaluate the performance of visual, radiographic and fluorescence-based methods in the detection of caries lesions in permanent and primary teeth, to perform meta-analysis of the overall performance of the methods and to investigate possible sources of heterogeneity. Three distinct systematic reviews related to each diagnostic method were performed. Four observers evaluated the articles, at least two per method. They performed the search and study selection independently; a researcher with experience in caries diagnostic studies solved the cases of conflict or doubt. Electronic databases used were MEDLINE, EMBASE and Scopus, to reduce publication bias, were also pursued academic papers and unpublished documents through OpenSigle and the Annals of ORCA Congress. After the selection of studies by well-defined inclusion and exclusion criteria, data were collected and recorded, independently by each reviewer. Methodological quality assessment was performed through Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS) and statistical analysis using Paired Forest Plot, Summary Receiver Operating Characteristics analysis (SROC), relative diagnostic odds ratio (RDOR), sensitivity analysis and funnel plot, in addition we explored possible sources of heterogeneity. Regarding the accuracy of visual method, 102 articles met the inclusion criteria. In general, visual analysis showed that the method had a good accuracy in the detection of caries lesions. Although laboratory and clinical studies have shown similar accuracies, clinical studies have obtained higher specificities. We also observed moderate to high heterogeneity and evidence of publication bias in most studies. In addition, the use of visual scoring systems resulted in significantly better accuracy compared to studies using their own criteria. Concerning the clinical relevance of accuracy studies of visual method, 96 studies were included. In general, most studies failed to consider some relevant clinical aspects: only 1 study included assessment of activity of the lesions; no study considered their prognosis; 79 studies did not consider a relevant clinical outcome and only 1 evaluated a patient-centered outcome. With regard to the methodological quality, most of the present studies showed a high risk of bias in the selection of the sample. With concern to the radiographic method, 116 articles were selected. Conventional and digital radiographic methods showed similar performance, showing greater specificity values compared to sensitivity, and higher AUC values at the threshold of more advanced caries lesions. Regarding fluorescence-based methods, 75 studies met the inclusion criteria. In general, the analysis demonstrated that the fluorescence-based method tend to have similar accuracy for all types of teeth, dental surfaces or settings. There was a trend of better performance of fluorescence methods in detecting more advanced caries lesions. We also observed moderate to high heterogeneity and evidenced publication bias. In conclusion, the visual method of detecting caries lesions has a good overall performance, but studies should consider relevant clinical outcomes, as well as accuracy. In addition, they should be conducted with greater methodological quality, especially in relation to sample selection. Still, the use of detailed and validated indices seems to improve the accuracy of the method. Radiographic method showed no difference between the image acquisition modes (digital or conventional), showing a tendency to higher values of specificity and performance in advanced caries lesions. Fluorescence-based devices showed similar overall performance; however, a better accuracy in detecting more advanced caries has been observed.
48

Avaliação da punção aspirativa por agulha fina (PAAF) em cavidade oral e região de cabeça e pescoço em diferentes técnicas de coloração / Evaluation of Fine Needle Aspiration Biopsy (FNAB) in oral cavity and head and neck region with different techniques stains

Santos, Ana Paula Candido dos 22 August 2014 (has links)
O presente estudo teve como objetivo avaliar a Punção Aspirativa por Agulha Fina (PAAF) em diferentes técnicas de coloração, em lesões nodulares de cavidade oral e região de cabeça e pescoço, quanto a sua sensibilidade, especificidade e acurácia, nas colorações de Panótico, Papanicolau e Hematoxilina-Eosina . Foram selecionados 46 pacientes consecutivamente que procuraram a Clínica da Disciplina de Estomatologia Clínica da FOUSP, portadores de lesões nodulares em cavidade oral e região de cabeça e pescoço. Como critérios de inclusão foram selecionados pacientes de ambos os sexos, todas as etnias, acima dos 5 anos de idade, sem restrição de comorbidades e que foram realizadas PAAF com confirmação diagnóstica pela biópsia. Como critérios de exclusão da pesquisa estão os pacientes abaixo dos 5 anos de idade e pacientes que foram somente submetidos a PAAF sem confirmação diagnóstica pela biópsia. O material obtido pela PAAF foi enviado em 6 lâminas diferentes, corados pelo método de Panótico, Papanicolau e Hematoxilina-Eosina a um mesmo patologista apenas com o diagnóstico clínico. Após a emissão do laudo da PAAF, o laudo do anátomo patológico era emitido, servindo como padrão ouro. Após os cálculos, o resultado da sensibilidade, especificidade e acurácia para o método de coloração com o Panótico foram de 28,6%, 76%, 15,4, respectivamente, para o método de coloração com o Papanicolau foram de 71,4%, 76,7%, 23,3%, respectivamente e para o método de coloração com a Hematoxilina-Eosina foram de 82,1%, 23,3%, 28,6%, respectivamente. Houve diferença estatisticamente significativa na proporção de sensibilidade, especificidade e acurácia entre as diferentes técnicas de coloração (X2 13,27, p=0,01). Podemos concluir que, na metodologia do presente estudo, as colorações de Hematoxilina-Eosina e Papanicolau demonstraram a mesma sensibilidade, para diagnosticar neoplasias malignas. A coloração de Hematoxilina-Eosina demonstrou uma melhor especificidade para diagnosticar neoplasias benignas, quando comparadas com a colorações de Papanicolau e Panótico. A coloração de Hematoxilina-Eosina demonstrou uma melhor acurácia, para dar diagnóstico definitivo, seguida das colorações de Papanicolau e Panótico. / The present study aimed to evaluate the Fine Needle Aspiration Biopsy in different staining techniques in nodular lesions of the oral cavity and head and neck region, as their sensitivity, specificity and accuracy, staining with Panoptic, Papanicolaou and Hematoxylin-Eosin. 46 patients who sought the Clinic of the Discipline of Clinical Stomatology at FOUSP were selected consecutively, with nodular lesions in the oral cavity and head and neck region. Inclusion criteria were patients of both sexes, all ethnicities, above 5 years-old, with no restriction of comorbidities and FNAB performed with confirmation by biopsy. Exclusion criteria were patients under 5 years-old and patients who only underwent FNAB without confirmation by biopsy. The material obtained by FNAB was sent on 6 different slides, stained by the method of Panoptic, Papanicolaou and Hematoxylin-Eosin, to the same pathologist only with the clinical diagnosis. After the final report of FNAB, the biopsy report was issued, serving as gold standard. After the calculations, the results of sensitivity, specificity and accuracy for Panoptic staining were 28.6%, 76% and 15.4%, respectively. The result of sensitivity, specificity and accuracy for Papanicolaou staining were 71,4%, 76.7% and 23.3%, respectively. The result of sensitivity, specificity and accuracy for Hematoxylin-Eosin staining were 82.1%, 23.3%, 28.6%, respectively. There was a statistically significant difference in the proportion of sensitivity, specificity and accuracy between the different staining techniques (X2 13.27, p = 0.01). We can conclude, in the methodology of this study that, Hematoxylin-Eosin and Papanicolaou stains showed the same sensitivity of diagnosing malignant neoplasms. The Hematoxylin-Eosin stain showed a better specificity for diagnosing benign neoplasms, compared with Papanicolaou and Panoptic stains. Hematoxylin-eosin stain showed better accuracy, to give definitive diagnosis, followed by Papanicolaou and Panoptic stains.
49

Acurácia diagnóstica de diferentes critérios para síndrome metabólica e análise de características associadas em pacientes epilépticos adultos

Cabral, Lucas Scotta January 2011 (has links)
As doenças cardiovasculares ateroscleróticas (DACV) não só têm apresentado prevalência crescente em portadores de epilepsia, mas também acarretam prognóstico menos favorável do que nas populações de controle. A busca pelos critérios para definir de síndrome metabólica (SDMET) padroniza a avaliação de fatores de risco (FR) metabólicos de especial interesse, e consequentemente, ajuda na avaliação do risco cardiovascular. Neste trabalho, buscamos desenhar um estudo transversal para avaliar e comparar a acurácia diagnóstica de diferentes critérios de SDMET entre adultos epilépticos em risco de eventos cardiovasculares. Também objetivamos analisar as associações entre fatores clínicos / neurológicos e a ocorrência de SDMET. Noventa e cinco pacientes foram recrutados e avaliados de acordo com os critérios National Cholesterol Education Program’s Adult Treatment Panel III (NCEP ATP3), American Association of Clinical Endocrinologists (AACE), International Diabetes Federation (IDF), American Heart Association / National Heart, Lung and Blood Institute (AHA/NHLBI) e International Diabetes Federation / National Heart, Lung and Blood Institute / American Heart Association / International Atherosclerosis Society / International Association for the Study of Obesity (IDF/NHLBI/AHA/WHF/IAS/IASO.) Os adultos com epilepsia tiveram prevalência elevada de SDMET (34,8- 49,4%), se comparados com referenciais históricos. Os critérios IDF demonstraram a maior sensibilidade [S = 95,5% (IC 95% 84,5-99,4)]. Os critérios AACE demonstraram o menor valor preditivo negativo [VPN = 75,4% (IC 95% 68,5-77,7)]. A obesidade foi o distúrbio metabólico mais frequente (53,9-79,8%), e a dislipidemia foi o que teve melhor concordância com o diagnóstico da síndrome (κ = 0,391 a 0,691, p<0,001). Regressão logística binária reafirmou a associação entre SDMET e idade [RC = 1,03 (IC 95% 1,001-1,06)], comorbidade psiquiátricas [RC = 2,57 (IC 95% 1,01-6,51)] e não ter história de status epilepticus [RC = 3,69 (IC 95% 1,15-11,87)]. Este estudo sugere que epilépticos adultos, investigados neste estudo, estão em risco particularmente elevado para eventos cardiovasculares. Neste contexto, uma correta avaliação pode melhorar as taxas de detecção de SDMET e incentivar medidas de prevenção primária. Dessa forma, sugerimos que uma avaliação estruturada de risco cardiovascular desses pacientes deveria ser incorporada na prática rotineira dos cuidados aos pacientes com epilepsia. / Cardiovascular atherosclerotic diseases not only are increased in prevalence among epileptic patients but also portend them a worse prognosis. Searching for criteria to fulfill metabolic syndrome definition helps in estimating cardiovascular risk in a standardized fashion. We designed a cross-sectional study to assess and compare the diagnostic accuracy of different metabolic syndrome criteria among adults at risk for cardiovascular events. We also sought to analyze associations between clinical / neurological factors and metabolic syndrome occurrence. Ninety-five patients were enrolled and evaluated according to the ATP3, AACE, IDF, AHA / NHLBI and the IDF/NHLBI/AHA/WHF/IAS/IASO criteria. Epileptics had high metabolic syndrome prevalence (34.8-49.4%) when compared to historic references. IDF criteria showed the highest sensitivity [S = 95.5% (CI 95% 84.5-99.4)]. AACE criteria showed the lowest negative predictive value [NPV = 75.4% (CI 95% 68.5-77.7)]. Obesity was the most frequent metabolic disturbance (23.9-79.8%), and dyslipidemia showed the greatest concordance with the syndrome (κ = 0.391 to 0.691, p<0.001). Binary logistic regression supported an association of metabolic syndrome and age [OR = 1.03 (95% CI 1.001-1.06)], psychiatric comorbidities [OR = 2.57 (95% CI 1.01-6.51)] and not having a history of status epilepticus [OR = 3.69 (95% CI 1.15-11.87)]. This study adds evidence that adult epileptics are at especially high risk for cardiovascular events. Correct assessment can improve metabolic syndrome detection rates and foster primary prevention. Structured cardiovascular risk assessment should be incorporated in routine epilepsy care.
50

Composição corporal de escolares de 10 a 15 anos : um estudo longitudinal

Moreira, Rodrigo Baptista January 2009 (has links)
Acompanhar como se manifesta o perfil da composição corporal (CC), bem como identificar crianças com risco é considerado um parâmetro de saúde. Neste sentido, o presente estudo tem como objetivo identificar o comportamento da CC de escolares com idades entre 10 e 15 anos, nos dois sexos, acompanhadas de forma longitudinal; construir uma distribuição percentílica dos valores do % de gordura; identificar qual indicador antropométrico (IMC, IC e PC) apresenta maior poder discriminatório para o sobrepeso/obesidade, tendo como referência o % de gordura; bem como determinar os pontos de cortes. O banco de dados utilizado na presente investigação é secundário. As informações utilizadas para realização das análises deste estudo fazem parte do banco de dados do PROESP-BR. Para o desenvolvimento do estudo longitudinal, foram utilizados os dados coletados no ano de 2003 até o ano 2008. A amostra foi composta por 71 crianças que participaram de todas as coletas, sendo 30 rapazes e 41 moças. Para a realização do cálculo do % de gordura foram adotadas as equações propostas por Slaughter et al. (1988). Para a análise do perfil da CC nas diferentes idades e sexo, inicialmente analisamos os dados através de um estudo exploratório com o objetivo de avaliar os pressupostos essenciais da análise paramétrica. Após a inspeção, utilizamos médias e desvio-padrão para a descrição dos dados. Quanto ao estudo do dimorfismo sexual nos componentes da CC, utilizamos o teste "t" de student para amostras independentes. Para a avaliação das diferenças entre as idades nos componentes da CC, nos dois sexos, recorremos a ANOVA para medidas repetidas. Para a identificação de qual o teste possui maior poder discriminatório para a identificação do sobrepeso/obesidade, optou-se em estimar o % de gordura como "padrão de referencia" estabelecido a partir dos critérios propostos por Lohman (1987). Inicialmente foi identificada a área total sob a curva ROC entre o IMC, IC, PC e % de gordura. Na seqüência, foi calculada a sensibilidade (SENS) e a especificidade (ESP) entre o % de gordura e as demais variáveis antropométricas. A partir da interação entre SENS e ESP foram estabelecidos os pontos de cortes para o IMC, IC e PC. No que se refere aos resultados do comportamento da CC, percebemos que o % de gordura dos rapazes apresentam valores inferiores ao das moças ao longo de todas as idades e certa redução do % de gordura, principalmente, a partir dos 11 anos. No tocante aos resultados das moças, observamos um comportamento distinto em relação aos rapazes, às moças aumentam o % de gordura ao longo das idades. Para a massa gorda (MG) identificamos um comportamento semelhante entre rapazes e moças, no entanto os valores das moças são superiores ao dos rapazes, evidenciando um desenvolvimento mais acentuado. Nos resultados da massa corporal magra (MCM), identificamos um comportamento parecido entre os sexos, sendo os valores das moças inferiores ao dos rapazes, apresentando diferenças entre os sexos a partir dos 12 anos. No que se refere às análises das relações entre as variáveis antropométricas podemos constatar que entre elas a mais indicada para discriminar crianças com maior risco de desenvolvimento de doenças de ordem metabólica associada ao sobrepeso/obesidade é o IMC. Sobre os pontos de cortes apresentados pela literatura para o IMC, os resultados sugerem que os critérios internacionais apresentam menor poder discriminatório do que os critérios nacionais quando da avaliação do sobrepeso/obesidade de crianças brasileiros. Sugere-se a utilização dos pontos de cortes apresentados na presente investigação, pois estes foram os que apresentaram melhor equilíbrio entre SENS e ESP em comparação com os critérios sugeridos na literatura, bem como estabelecido um ponto de corte para cada idade. / To follow if manifest the profile of body composition (CC), well to identify children to them with risk to the health is identified as a health parameter. In this direction, the present study it has as objective to identify the behavior of CC of pertaining to school with ages between ten and fifteen years, in the two sexs, followwed of longitudinal form; to construct a percentilic distribution of the values of the percentage of fat; to identify to which the values of the total area under curve ROC for the IMC-kg/m², index of coning (IC) and perimeter of the waist (PW), having as reference the percentage of fat, as well as determiner the points of cuts. The data base used in the present inquiry is secondary. The information used for the accomplishment of analyzes of this study are part of the data base of the PROESP-BR. For the development of the longitudinal study, had been used the data collected in the year of 2003 until the year of 2008. The sample was composed for seventy-one children who had participated of all the collections, being thirty youngsters and forty and one young women. For the accomplishment of the calculation of the percentage of fat the equations had been adopted proposals for Slaughter et al. (1988). For the analysis of the profile of the CC in the different ages and sexs, initially we have analyzed the data through of an explorator study with the objective to evaluate the essential estimated ones of the parametric analysis. After the inspection, we used measured and shunting line-standard for the description of the data. About the study of the sexual dimorfismo in the components of the corporal composition, we use test "t" of student for independent samples. For the evaluation of the differences between the ages in the components of the CC, in the two sexs, we appeal the ANOVA for repeated measures. For the identification of which the test has greater to be able discriminatory for the identification of the overweight/obesity was opted in esteem the percentage of fat as "established standard of reference" from the criteria considered for Lohman (1987). Initially the total area under curve ROC between the IMC, IC, PC and percentage of fat was identified. In the sequence, the SENS and ESP were calculated between the percentage of fat and the excessively changeable anthropometrics. Later of the interaction between SENS and ESP the points of cuts for the IMC, IC had been established and PC. As for the results of the behavior of the CC, we perceive that the percentage of fat of the youngsters presents inferior values to the one of the young women throughout all the ages and certain reduction of the percentage of fat, mainly, from the eleven years. In regards to the results of the young women, its observed a distinct behavior in relation to the youngsters, the young women increase the percentage of fat throughout the age. For the fat mass we identify to a similar behavior between youngsters and young women, however the values of the young women are superior to the one of the youngsters, evidencing an accented development more. In the results of the MCM, is identified a behavior similar between the sexs, being the values of the inferior young women to the one of the youngsters, presenting differences between the sexs from the twelve years. As for the analyses of the relations between the antropometrics variable we can evidence that it enters they more indicated it to discriminate the children with bigger risk of development of illnesses of metabolic order associated to the overweight/obesity is the IMC. On the points of cuts presented for literature for the IMC, the results suggest that the international criteria present little discriminatory power of what the national criteria when of the evaluation of the overweight/obesidade of Brazilian children. It is suggested use of the points of cuts presented in the present inquiry, therefore these had been the ones that better present balance between SENS and ESP in comparison with the criteria suggested in literature, as well as established a point of cut for each age.

Page generated in 0.0537 seconds