Spelling suggestions: "subject:"estatísticas não paramétrica"" "subject:"estatísticas não paramétricos""
1 |
Malacofauna límnica do reservatório da Usina Hidrelétrica de Cana Brava \2013 GO, com ênfase em Biomphalaria straminea (Dunker, 1848), transmissora natural da EsquistossomoseBuchmann, Fábio Fiebrig January 2014 (has links)
Made available in DSpace on 2016-03-28T12:43:39Z (GMT). No. of bitstreams: 2
fabio_buchmann_ioc_mest_2014.pdf: 3583935 bytes, checksum: 268a8158a781cf0e26c19ad50ab0aab5 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2016-02-23 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil / O impacto ambiental causado pela construção de hidrelétricas favorece a proliferação de espécies transmissoras de parasitoses humanas, como a esquistossomose, tornando obrigatórios os estudos direcionados nestas áreas. A ocorrência da espécie vetora da esquistossomose Biomphalaria straminea no entorno da hidrelétrica de Cana Brava (UHCB) e a susceptibilidade de suas populações ao Schistosoma mansoni, justificam a realização de pesquisas sistemáticas em seu reservatório. Neste trabalho foram investigados 87 biótopos favoráveis à ocorrência de moluscos límnicos, bimestralmente, entre maio de 2012 a fevereiro de 2014, a fim de mapear a distribuição destes animais na área de influência da UHCB. Dentre estes, 10 pontos, abrangendo os principais rios e alguns tributários, foram selecionados para o estudo quantitativo. Também foi investigada a infecção de moluscos por trematódeos e verificados os parâmetros abióticos: pH, oxigênio dissolvido, condutividade e temperatura da água. Todas as estações de amostragem foram georreferenciadas. Foram encontrados gastrópodes pertencentes às famílias Ampullariidae, Thiaridae, Planorbidae, Ancylidae, Physidae e Lymnaeidae, incluindo as espécies vetoras de parasitoses humanas (B. straminea, Pomacea lineata e Lymnaea columella) e as espécies exóticas (Melanoides tuberculata e Physa acuta). Em relação à frequência de ocorrência apenas B. straminea e M. tuberculata se mostraram constantes
Embora tenham sido encontrados seis diferentes tipos cercarianos (Brevifurcate apharingeate, Pleurolophocercous, Vivax, Monostome, Echinostome e Armatae), nenhum molusco foi encontrado albergando formas larvais de Schistosoma mansoni ou Fasciola hepatica. No entanto, Pleurolophocercous cercaria, presente em M. tuberculata, pode pertencer às famílias Opisthorchiidae e Heterophyidae, que compreendem trematódeos de importância médica. Para verificar a relação entre a abundância de moluscos e os parâmetros abióticos, foi utilizado o coeficiente de Spearman, o qual mostrou uma correlação positiva, na campanha de novembro de 2013, entre o pH básico e a abundância de M. tuberculata. A presença constante de B. straminea na área da UHCB, somada às mudanças socioambientais ocorridas, indica a necessidade de monitoramento desses moluscos entre as medidas de prevenção à instalação de focos de esquistossomose / Environmental impact caused by hydroelectric power plants favor the dispersion of vector
species of human parasites and make mandatory researches in these areas. Occurrence of
Biomphalaria straminea,
vector sp
ecies of schistosomiasis, was already recorded in the
surroundings of Cana Brava Dam (UHCB). Previous studies also demonstrated that
B.
straminea
from these areas is susceptible to experimental infection by
Schistosoma mansoni
,
justifying the systematic st
udies in UHCB area. In this study 87 favorable biotopes were
investigated every two months for the occurrence of freshwater snails, from May 2012 to
February 2014. Ten points covering the major rivers and some tributaries were selected for the
quantitative
study and measured abiotic factors, such as pH
-
value, dissolved oxygen, water
temperature and electric condutivity. The infection of snails by trematodes was also
investigated. All sites were georeferenced. We recorded gastropods from the families
Ampulla
riidae, Thiaridae, Planorbidae, Ancylidae, Physidae and Lymnaeidae, including
vectors of human parasites (
B. straminea
,
Pomacea lineata
and
L. columella
) and exotic
species (
Physa acuta
and
Melanoides tuberculata
). Regarding the frequency of occurrence,
on
ly
B. straminea
and
M. tuberculata
were constant. Despite the presence of six different types
of cercarie (Brevifurcate apharingeate, Pleurolophocercous, Vivax, Monostome, Echinostome
and Armatae), no parasite of medical importance was found. However, Pleu
rolophocercous
cercaria, present in
M. tuberculata
, can belong to families which comprise flukes of medical
importance, as Heterophyidae and Opisthorchiidae. The
Spearman
coefficient, used to verify
the relationship between abundance of snails and abiotic
parameters, showed a positive
correlation, in November 2013, between basic pH and the abundance of
M. tuberculata
. The
constant presence of
B. straminea
in UHCB area and the social and environmental changes
indicates the need for monitoring these snails am
ong the preventive measures for the
installation of schistosomiasis foci.
|
2 |
Testes de hipóteses frequentistas e bayesianos para razão áurea via simulação Monte CarloSANTOS, Mariana Moreira Gonçalves 30 March 2015 (has links)
A razão áurea é uma constante irracional que tem sido investigada por pesquisadores de diversas
áreas do conhecimento. Presente na natureza e bastante utilizada em pinturas, esculturas e construções,
a razão áurea está relacionada com a beleza perfeita e a proporção ideal. Atualmente
pesquisas têm associado propriedades como bom funcionamento, eficiência e estabilidade a
estruturas biológicas que possuem essa razão. Para inferir sobre a razão áurea, pesquisadores
têm utilizado diversas metodologias, dentre elas, o teste t de Student, testes não paramétricos
e, em muitos casos, critérios subjetivos. Para se inferir sobre a média das razões de duas
populações não há na literatura um teste específico. Muitos pesquisadores, para inferir se a
razão de determinados segmentos são iguais ao número de ouro zero , utilizam a média das razões
amostrais, para estimar a média das razões populacionais e utilizam o teste t de Student. A
razão de duas variáveis aleatórias quando são independentes, normais padrão é uma variável
aleatória que segue uma distribuição de Cauchy. No entanto, quando as variáveis aleatórias
são dependentes, como é o caso em que se quer inferir sobre a razão áurea, a distribuição
de probabilidade da razão não é conhecida e a inferência baseada em pressuposições que não
são satisfeitas pode levar a resultados não confiáveis. Um dos objetivos desse trabalho foi
avaliar a viabilidade do teste t de Student com diferentes estatísticas, algumas já utilizadas por
pesquisadores e uma proposta, para se inferir sobre a razão áurea. Também foram avaliadas
outras metodologias propostas: o teste não paramétrico Wilcoxon e o teste bayesiano com
priori não-informativa. A avaliação das metodologias dos testes paramétricos e não-paramétrico
se deu através da quantificação e comparação das taxas de erro tipo I e poder dos testes em
diferentes situações de variabilidade e tamanhos de amostra, via simulação Monte Carlo. Para
avaliação do teste bayesiano, quantificou-se as taxas de rejeição de H0 nas simulações quando
as amostras foram geradas sob H0 e sob H1. Como aplicação, foram obtidos dados referentes à
medida dos braços de nove pares de cromossomos de células do genótipo Cerbiatta da Lactuca
sativa L., a alface e os testes foram comparados quando aplicados nessa amostra. Todas as
simulações e as comparações dos testes foram realizadas no programa R. O t de Student com
as estatísticas utilizadas em literatura foi liberal ou apresentou taxas de poder inferiores a
95% na maioria dos cenários e, por isso, não é recomendado. O teste bayesiano com priori
de Jeffreys foi equivalente ao teste t de Student com a estatística proposta, que por sua vez,
apresentou melhor desempenho no controle das taxas de erro tipo I, mas apresentou taxas de
poder inferiores a 95% para amostras pequenas, principalmente quando a variabilidade dos dois
segmentos é maior. Foi verificado que havia a presença de razão áurea nas medidas dos braços
longo e curto do quinto par de cromossomo. / The golden ratio is an irrational constant that has been investigated by researchers from various
fields of knowledge. Present in nature and widely used in paintings, sculptures and buildings,
the golden ratio is related to the perfect beauty and the ideal proportion. Currently research has
associated properties such as proper functioning, efficiency and stability at biological structures
that have golden ratio. In order to study the golden ratio, researchers have used different
methodologies, such as, the Student’s test, non-parametric tests and, in many cases, subjective
criteria. There is no, in the literature, a specific test to infer about the mean ratio of two
populations. Many researchers, to infer if the rate of certain segments are, on average, equal to
the number of gold , use the of sample rates average to estimate the mean of population rates
and use the Student’s test. The ratio of two independent random variables standard normal is a
random variable that follows a Cauchy distribution. However, when the random variables are
dependent, as is the case where it is desired infer about the golden ratio, the ratio probability
distribution is not known. The infer process based on assumptions that are not satisfied can lead
to unreliable results. One goal of this study was to evaluate the viability of the Student’s test
with different statistics, some of them, already used by researchers, and a proposal one to infer
the golden ratio. We evaluated other methodologies proposed: the nonparametric Wilcoxon
test and the Bayesian test with non-informative priori. The evaluation of the methodologies
of parametric tests and nonparametric occurred by quantifying and comparing of the tests
type I errors rate and power in different situations variability and sample sizes, via Monte
Carlo simulation. To evaluate the Bayesian test, it was quantified rejection rates of H0 in the
simulations when the samples were generated under H0 and under H1. As an application, it
was obtained data refers the measuring of the arms of nine pairs of the chromosomes of the cell
Cerbiatta genotype of Lactuca sativa L., the lettuce and the tests were compared when applied
in this sample. All simulations and comparisons of tests were performed using the statistical
software R. The Student’s test with the statistics used in literature was liberal or had power rates
less than 95% in most scenarios and therefore is not recommended. The Bayesian test with
Jeffreys’s priori was equivalent to the Student’s test with the statistical proposal, which in turn
performed better on the control of Type I error rates, but showed lower power rates less than
95 % for small samples, especially when the variability of the two segments is large. It was
verified that there is the presence of golden ratio in the rate between long and short arms in the
fifth pair of chromosome. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
|
3 |
Avaliação da sensibilidade cutânea em pés de pacientes diabéticos através do Pressure Specified Sensory Device TM / Evaluation of cutaneous sensibility threshold on the feet of diabetic patients with the Pressure Specified Sensory Device(TM)Carvalho, Viviane Fernandes de 04 March 2008 (has links)
A neuropatia diabética causa diminuição ou perda da sensibilidade protetora do pé, tornando-o mais vulnerável ao trauma mecânico e térmico. A profilaxia das complicações neuropáticas tem início pela identificação da perda de sensibilidade e, portanto, do comprometimento neurológico. O Pressure Specified Sensory Device(TM) (PSSD) é um equipamento desenvolvido para quantificar o limiar de pressão, aplicada sobre a pele, necessária para que o paciente perceba o estímulo provocado por: um ponto estático, um ponto em movimento, dois pontos estáticos e dois pontos em movimento. Denominamos grupo estudo, aos trinta e quatro pacientes diabéticos do tipo 2, sem história prévia de feridas e/ou amputações nos pés que foram submetidos à avaliação de sensibilidade cutânea utilizando-se o PSSD(TM). Foram realizados testes nos territórios cutâneos dos nervos fibular profundo, plantar medial e ramo calcâneo do nervo tibial posterior. Estímulos foram provocados segundo as modalidades: um ponto estático (1 PE), um ponto em movimento (1 PD), dois pontos estáticos (2 PE) e dois pontos em movimento (2 PD), para as duas últimas modalidades. Previamente às modalidades 2PE e 2PD determinou-se o limiar de discriminação entre dois pontos estáticos (D2PE) e em movimento (D2PD). Foram realizados apenas no grupo estudo, testes com o monofilamento de Semmes-Weisntein nº 5,07 (MSW) e com o diapasão de 128 Hz. Vinte e oito pacientes não-diabéticos, submetidos aos mesmos testes, formaram o grupo controle. Para os limiares de sensibilidade, encontramos valores superiores no grupo estudo (p < 0,05). Ao compararmos os limiares de sensibilidade alcançados pelos pacientes diabéticos sensíveis e não sensíveis ao estímulo promovido pelo MSW nº 5,07 verificamos que o p-valor variou entre 0,018 < p < 0,113 para 1 PE e 0,002 < p < 0,083 para 2 PE, conforme o território cutâneo estudado. Na comparação dos limiares de sensibilidade da modalidade 1 PD entre diabéticos sensíveis e insensíveis à vibração do diapasão de 128 Hz, as diferenças não foram estatisticamente significantes (p = 0,183). Os resultados obtidos nos permitiram sugerir que o dispositivo PSSD(TM) seja utilizado como forma de acompanhamento do comprometimento da fibra nervosa. / Neuropathy is a severe progressive loss of protective sensation on the feet, making the patient more vulnerable to mechanical trauma and consequently more suitable to the development of chronic wounds, major distortion of the foot bone architecture and eventually to limb amputation. Prophylaxis should be enforced to avoid foot ulceration and for that, evaluation of the degree of loss of sensation on the skin is essential. The PSSD (Pressure Specified Sensory Device(TM)) was developed in order to quantify the threshold of pressure applied to the skin that could be recognized as positive by the patient. Pressure of one or two points is tested both statically and with movement, thus assessing the function of fast and slow response nerve fibers. Threshold of two-point discrimination was also measured in mm. Thirty four (n = 34) diabetic patients, type II, with no previous history of wounds on the lower extremity were studied using the tests, one point static (1PE), one point moving (1PD) and two points static (2 PE), and moving (2 PD) on the cutaneous territory of the fibular nerve and posterior tibial nerve (two territories - medial plantar and calcaneous nerves). The control group (28 non diabetic patients) was assessed by the same exams and the results were compared. In the diabetic group the cutaneous territories were also evaluated using the conventional Semmes-Weinstein filament nº 5,07 e vibrometer of the 128 Hz. Altered values were observed for the static and dynamic tests over the three studied nerve territories. The differences were statically significant (p < 0,05). Comparing the threshold of sensibility between sensitive and non sensitive diabetic patients to MSW nº 5,07 test, we observed that p-value range was 0,018 0,113 when 1PE test was applied, and 0,002 0,083 when 2PE test was applied, according to the cutaneous territories evaluated. Numeric quantification of the threshold of pressure allows us to determine the status of the fiber/receptor structures as well as the functional deficit of nerve fibers. Our findings suggest that PSSD(TM) is an adjuvant tool to evaluate the degree of loss of sensation on the skin.
|
4 |
Avaliação da espirometria de gestantes expostas à poluição atmosférica da Região Metropolitana de São Paulo / Spirometric evaluation of pregnant women exposed to air pollution in the metropolitan region of São PauloPastro, Luciana Duzolina Manfré 11 March 2015 (has links)
Introdução: A poluição do ar pode levar a alterações no sistema respiratório, especialmente entre certos grupos, como as gestantes, que são mais vulneráveis aos efeitos de poluentes atmosféricos. A gravidez é um período que envolve alterações funcionais e anatômicas no corpo da mulher, incluindo alterações na função pulmonar, o que pode ser avaliado por espirometria, um método simples, barato e eficaz. Objetivos: Os objetivos deste estudo foram a usar a espirometria para avaliar a função pulmonar de mulheres no primeiro trimestre (T1) e no terceiro trimestre (T3) de gravidez e analisar a influência da exposição a poluição do ar sobre os parâmetros espirométricos. Metodologia: O estudo foi realizado no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) entre Maio de 2011 e Agosto de 2013. Foram aplicados os seguintes critérios de inclusão: gestação única, idade gestacional no dia da primeira espirometria inferior a 13,86 semanas, ausência de doenças maternas préexistentes, preparação adequada para o teste de espirometria e amostradores passivos individuais (APIs) adequados para análise. Os critérios de exclusão foram a mudança de endereço, o aborto, o teste de espirometria inadequado e desistência de participar do projeto. Os APIs contendo dois filtros de celulose embebidos com solução absorvente para capturar os níveis de NO2 e outros dois filtros embebidos com solução de índigo blue para medir os níveis de O3 foram entregues às gestantes cerca de 12 dias antes da realização do teste de espirometria. Dados do relatório anual da Companhia Ambiental do Estado de São Paulo (CETESB) para o mesmo período dos amostradores passivos, foram utilizados. Para a espirometria, um espirômetro Koko foi utilizado, sendo considerada as duas melhores curvas para avaliar os resultados da função pulmonar. Análise estatística: Foi utilizado o teste Mann-Whitney para grupos independentes e Wilcoxon para os dependentes. Devido à pequena variação na exposição à poluição, a exposição no primeiro trimestre (Q1) e quarto trimestre (Q4) foram comparados para cada poluente em T1 e T3 através da análise nãoparamétrica para medidas repetidas. Resultados: Houve uma redução estatisticamente significativa dos valores absolutos (T1: 3,690 L; T3: 3,475 L) e preditos (T1: 101%, T3: 97,5%) da capacidade vital forçada (CVF), p < 0,0001. E uma redução estatisticamente significativa dos valores absolutos (T1: 3.080 L; T3: 2.950 L) e preditos (T1: 99%, T3: 96%) do volume expiratório forçado no primeiro segundo do procedimento (FEV1), p < 0,0001. A exposição à poluição foi semelhante em ambos os trimestres, exceto para a exposição de NO2 no API, o que foi inferior em T3 (p = 0,001). Independentemente do trimestre (T1 ou T3), o grupo de mulheres do Q4 (T1: 97,5%; T3: 98,5%) teve NO2 estatisticamente maior dos valores do fluxo expiratório forçado de 25 a 75% do procedimento (FEF25-75%) do que o grupo em Q1 (T1: 80%; T3: 92%). O grupo de mulheres do Q1 do NO2 teve um aumento significativo neste parâmetro de T1 a T3 (p = 0,042). Em termos de valores absolutos da relação FEV1/FVC, o grupo de mulheres no Q1 mostrou um aumento estatisticamente significativo neste parâmetro de T1 (0,810 L) para T3 (0,840 L) (p = 0,026). Em T3, os valores absolutos e relativos da CVF foram estatisticamente maiores para o grupo de gestantes do Q4 (3,535 L; 100,5%) de NO2 do que para o grupo de gestantes do Q1 (3,345 L; 92%). O grupo de gestantes do Q4 de O3 mostrou o VEF1 estatisticamente maior eno T1 (102,5%) do que no T3 (95,5%) (p < 0,001). Independentemente do trimestre, o grupo de gestantes do Q4 do MP10, teve valores absolutos da CVF (T1: 3.520 L; T3: 3,265 L) e os valores de VEF1 (T1: 2,915 L; T32.840 L) foram estatisticamente menor do que para o grupo em Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0,040; p = 0,035, respectivamente. Valores absolutos e preditos do pico de fluxo expiratório (PEF) em T1 das mulheres do Q4 (5,995 L; 80%) do MP10 foram estatisticamente menores do que para as mulheres no Q1 (6,675 L; 85%) (p = 0,006; p = 0,041 , respectivamente). Mulheres grávidas em Q4 (0,835 L) do MP10 tiveram os valores da relação VEF1/CVF estatisticamente menores valores do que as mulheres do Q1 (0,850 L) (p = 0,029). Conclusão: Exposição a NO2 e O3 foi associada com o aumento de alguns dos parâmetros de espirometria, indicando a presença de uma possível função de defesa pulmonar ou mecanismo compensatório em mulheres grávidas, quando expostos a esses poluentes. O MP10 foi associado com a redução de alguns parâmetros de espirometria durante a gravidez, indicando os efeitos danosos do poluente para a função do pulmão de mulheres grávidas / Introduction - Air pollution can lead to alterations to the respiratory system, particularly among certain groups, such as pregnant women, which are more vulnerable to the effects of air pollutants. Pregnancy is a period involving functional and anatomical changes in a woman\'s body. These changes include pulmonary function, which can be assessed by spirometry, a simple, inexpensive and effective method. Objectives - The aims of this study were to use spirometry to evaluate pulmonary function in pregnant women in the first trimester (T1) and the third trimester (T3) of pregnancy and to analyze the influence of air pollution exposure on the spirometry parameters. Methodology - This study was carried out at the Obstetrics Clinic of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) between May 2011 and August 2013. The following inclusion criteria were applied: singleton pregnancy, 13.86 weeks gestational age at the first spirometry, no preexisting maternal diseases, adequate preparation for the spirometry test and individual passive samplers (IPAs) suitable for analysis. The exclusion criteria were change of address, abortion, inadequate spirometry testing and withdrawal from the project. The exposure to pollutants prior to the spirometry tests was assessed in T1 and T3. The passive samplers containing two cellulose filters soaked with absorbent solution to capture NO2 levels and two other filters soaked with indigo solution to measure O3 levels were provided to the pregnant women roughly 12 days prior to the spirometry test. Data from the environmental Company of São Paulo State (CETESB) annual report for the same period the passive samplers were used. For the spirometry, a Koko spirometer was used, taking the two best curves to assess lung function results. Statistical Analysis - We used Mann- Whitney tests for independent groups and Wilcoxon for the dependent ones. Due to the small variation in the exposure to pollution, exposure in the first quarter (Q1) and fourth quarter (Q4) were compared for each pollutant in T1 and T3 through non-parametrical analysis for repeated measurements. Results - It has been noted a significant statistical reduction of absolute and predicted forced vital capacity (FVC) values (3.690 L; 3.475 L) and forced expiratory volume during the first second of the procedure (FEV1) (3.080 L; 2.950 L) from T1 to T3. Exposure to pollution was similar in both trimesters, except for exposure to NO2 in the passive sampler, which was lower in T3 (p = 0.001). Regardless of the trimester (T1 or T3), the group of pregnant women in Q4 (97.5%; 98.5%) of NO2 had statistically higher predicted forced expiratory values of 25 to 75% of the procedure (FEF25-75%) than the group in Q1 (80%; 92%). Pregnant women in Q1 of NO2 had a significant increase in this parameter from T1 to T3 (p = 0.042). In terms of absolute FEV1/FVC values, pregnant women in Q1 showed a statistically significant rise in this parameter from T1 (0.810 L) to T3 (0,840 L) (p = 0,026). In T3, absolute and predicted FVC values were statistically higher for the group of pregnant women in Q4 (3.535 L; 100.5%) of NO2 than for the group of pregnant women in Q1 (3.345 L; 92%). Pregnant women in Q4 of O3 displayed statistically higher FEV1 values in T1 (102.5%) than in T3 (95.5%) (p < 0.001). Regardless of trimester, for the group of pregnant women in Q4 of MP10, absolute FVC (T1:3 .520 L; T3: 3.265 L) and FEV1 values (T1: 2.915 L; T3: 2.840 L) were statistically lower than for the group in Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0.040; p = 0.035 respectively. Absolute and predicted peak expiratory flow (PEF) in T1 of pregnant women in Q4 (5.995 L; 80%) of MP10 were statistically lower than for the pregnant women in Q1 (6.675 L; 85%) (p = 0.006; p = 0.041, respectively). Pregnant women in Q4 (0.835 L) of MP10 displayed statistically lower absolute FEV1/FVC values than the pregnant women in Q1 (0.850 L) (p = 0.029). Conclusion - Exposure to NO2 and O3 was associated with the increase in some of the spirometry parameters, indicating the presence of a possible lung function defense or compensatory mechanism in pregnant women when exposed to those pollutants. The MP10 was associated with the reduction of some spirometry parameters during pregnancy, indicating the harmful effects of that pollutant to the lung function of pregnant women
|
5 |
Relação entre força muscular e função motora em pacientes com distrofia muscular de Duchenne: acompanhamento de quatro anos / Relationship between muscle strength and motor function in Duchenne muscular dystrophy: follow-up four yearsNunes, Milene Franco de Souza 08 April 2016 (has links)
OBJETIVO: Investigar a relação entre força muscular e função motora, em pacientes com DMD, em um período de 4 anos consecutivos, a partir de avaliações semestrais. MÉTODO: A força muscular foi medida por meio de testes manuais e o cálculo por grupo muscular seguiu o proposto pelo Medical Research Council (MRC) e a função motora pelo método de Medida da Função Motora (MFM), em 43 pacientes (8-30 anos). Foi realizada uma análise descritiva e o teste de correlação de Spearman. Foram investigadas as relações entre pontuações totais e parciais da MRC e da MFM. RESULTADOS: O estudo evidenciou correlações classificadas de moderada a forte relação entre a força muscular e função motora, principalmente com o escore total da MFM e a dimensão D2 (musculatura axial e função motora proximal). Foi encontrada relação negativa moderada entre idade e essas variáveis. CONCLUSÃO: A perda progressiva da função motora tem relação direta e proporcional com a diminuição da força muscular. Quanto maior a idade do paciente, pior sua função motora e força muscular, fornecendo com essa informação, indicadores adicionais da progressão da doença / OBJECTIVE: This study investigated this relationship and examined whether muscle strength and/or motor function would be related to age in DMD. METHODS: Muscle strength was measured by the Medical Research Council scale (MRC) and motor function by the Motor Function Measure (MFM) in 43 patients (8-30 yrs). Spearman tests, descriptive analysis, investigated the relationships between total/ partial scores of MRC and MFM. RESULTS: Total MRC and MFM scores were strongly related to each other and moderately related to age. Many strong relationships between partial MRC and MFM scores were found, mostly between partial MRC scores and MFM dimension 2 (axial and proximal motor function). CONCLUSION: It is possible to predict that the progressive loss of motor function has direct relationship to decreased muscle strength. That the older the patient, the worse their motor function and muscle strength, providing with this information, additional indicators of disease progression
|
6 |
Quantificação da carga isquêmica em pacientes com doença coronária avançada sintomática: comparação entre a perfusão miocárdica avaliada por ressonância magnética cardíaca e por cintilografia miocárdica / Ischemic burden in advanced coronary artery disease: comparison between myocardial perfusion by cardiovascular magnetic resonance and single-photon emission computed tomographyLeite, Thiago Nunes Pereira 16 August 2018 (has links)
Introdução: A quantificação da isquemia miocárdica é um dado de grande auxílio na tomada de decisões clínicas ou intervencionistas no tratamento da doença arterial coronária (DAC) avançada. Dentre os métodos disponíveis para esta finalidade, se destacam a cintilografia de perfusão miocárdica (CPM) e a ressonância magnética cardíaca (RMC), que além de fornecerem informações quanto à alteração de motilidade entre o estresse e o repouso, são capazes de analisar a perfusão miocárdica. Neste estudo, investigamos a correlação e a concordância entre esses dois métodos em pacientes com DAC sintomática e avançada. Métodos e Resultados: Cinquenta e três pacientes com DAC avançada (padrão obstrutivo triarterial) não elegíveis para revascularização completa devido à extensão e caráter difuso das lesões foram submetidos à RMC e à CPM. A maioria (57%) apresentava sintomas limitantes (angina CCS 3 ou 4). Na quantificação da carga isquêmica, o percentual de miocárdio isquêmico total (%Mioisquêmico) foi significativamente maior na RMC do que na CPM (25,3±13,7% vs. 20,5±13,5%, respectivamente; P = 0,02). A RMC identificou baixa carga isquêmica em apenas 15% dos pacientes, enquanto pela CPM 53% dos pacientes foram assim classificados. Foram encontradas correlações fracas entre os métodos para o %Miofixo, no %Mioestresse e %Mioisquêmico (coeficiente de Spearman variando de 0,06 a 0,54), assim como uma fraca concordância (kappa de 0,11 e bias elavado de 9,3 para %Mioisquêmico). De um total de 159 territórios coronarianos, 18 (11%) apresentaram grandes discordâncias (%Mioisquêmico pela CPM < 10% e > 20% pela RMC) em regiões do ventrículo esquerdo com alta probabilidade pré-teste de possuírem isquemia importante (miocárdio viável em território irrigado por artéria coronária ocluída cronicamente). Conclusão: A quantificação da carga isquêmica estresse-induzida avaliada pela CPM e pela RMC possui fraca correlação e concordância em pacientes com DAC avançada e complexa, com a RMC demonstrando uma maior carga isquêmica do ventrículo esquerdo, principalmente nas regiões com infarto prévio / Introduction: The quantification of myocardial ischemia is a key element in the decision-making process in patients with advanced coronary artery disease (CAD). Single-photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) are non-invasive tools for myocardial perfusion assessment. We investigated the correlation and agreement between these two methods in patients with symptomatic and complex CAD. Methods and Results: Fifty-three patients with advanced CAD (multivessel obstructive disease) not eligible for complete revascularization due the extension and diffuseness of the disease underwent both CMR and SPECT. The majority (57%) presented limiting symptoms (angina CCS 3 or 4). The quantification of the ischemic burden revealed that the mean percentage of total ischemic myocardium (%Myoischemic) was significantly higher as assessed by CMR compared with by SPECT (25.3±13.7% vs. 20.5±13.5%, respectively; P = 0.02). There were no significant correlations between CMR and SPECT regarding %Myostress (r = 0.23, p = 0.09), fixed (r = 0.20, p = 0.14), or ischemic (r = 0.11, p = 0.44). While SPECT classified 28 patients (53%) as having low ischemic burden (%Myoischemic < 10%), CMR classified only 8 patients (15%) in this category. Poor correlations between the two methods were found for %Myostress, %Myoischemic, and %Myofixed (Spearman\'s rho ranging from 0.06 to 0.54), depicting also slight agreement (kappa of 0.11 and bias as high as 9.3% for %Myoischemic). On a per-segment-based analysis, 18 coronary territories (11%) of the total 159, presented highly disagreements (%Myoischemic by SPECT < 10% and > 20% by CMR) in LV regions likely to have severe ischemia (viable myocardium supplied by chronically occluded vessels. Conclusion: The quantification of inducible myocardial ischemia by SPECT and CMR disagrees in patients with advanced and complex CAD, with CMR displaying greater left ventricular ischemic burden, particularly in patients with a previous myocardial infarction
|
7 |
Relação entre força muscular e função motora em pacientes com distrofia muscular de Duchenne: acompanhamento de quatro anos / Relationship between muscle strength and motor function in Duchenne muscular dystrophy: follow-up four yearsMilene Franco de Souza Nunes 08 April 2016 (has links)
OBJETIVO: Investigar a relação entre força muscular e função motora, em pacientes com DMD, em um período de 4 anos consecutivos, a partir de avaliações semestrais. MÉTODO: A força muscular foi medida por meio de testes manuais e o cálculo por grupo muscular seguiu o proposto pelo Medical Research Council (MRC) e a função motora pelo método de Medida da Função Motora (MFM), em 43 pacientes (8-30 anos). Foi realizada uma análise descritiva e o teste de correlação de Spearman. Foram investigadas as relações entre pontuações totais e parciais da MRC e da MFM. RESULTADOS: O estudo evidenciou correlações classificadas de moderada a forte relação entre a força muscular e função motora, principalmente com o escore total da MFM e a dimensão D2 (musculatura axial e função motora proximal). Foi encontrada relação negativa moderada entre idade e essas variáveis. CONCLUSÃO: A perda progressiva da função motora tem relação direta e proporcional com a diminuição da força muscular. Quanto maior a idade do paciente, pior sua função motora e força muscular, fornecendo com essa informação, indicadores adicionais da progressão da doença / OBJECTIVE: This study investigated this relationship and examined whether muscle strength and/or motor function would be related to age in DMD. METHODS: Muscle strength was measured by the Medical Research Council scale (MRC) and motor function by the Motor Function Measure (MFM) in 43 patients (8-30 yrs). Spearman tests, descriptive analysis, investigated the relationships between total/ partial scores of MRC and MFM. RESULTS: Total MRC and MFM scores were strongly related to each other and moderately related to age. Many strong relationships between partial MRC and MFM scores were found, mostly between partial MRC scores and MFM dimension 2 (axial and proximal motor function). CONCLUSION: It is possible to predict that the progressive loss of motor function has direct relationship to decreased muscle strength. That the older the patient, the worse their motor function and muscle strength, providing with this information, additional indicators of disease progression
|
8 |
Avaliação da espirometria de gestantes expostas à poluição atmosférica da Região Metropolitana de São Paulo / Spirometric evaluation of pregnant women exposed to air pollution in the metropolitan region of São PauloLuciana Duzolina Manfré Pastro 11 March 2015 (has links)
Introdução: A poluição do ar pode levar a alterações no sistema respiratório, especialmente entre certos grupos, como as gestantes, que são mais vulneráveis aos efeitos de poluentes atmosféricos. A gravidez é um período que envolve alterações funcionais e anatômicas no corpo da mulher, incluindo alterações na função pulmonar, o que pode ser avaliado por espirometria, um método simples, barato e eficaz. Objetivos: Os objetivos deste estudo foram a usar a espirometria para avaliar a função pulmonar de mulheres no primeiro trimestre (T1) e no terceiro trimestre (T3) de gravidez e analisar a influência da exposição a poluição do ar sobre os parâmetros espirométricos. Metodologia: O estudo foi realizado no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) entre Maio de 2011 e Agosto de 2013. Foram aplicados os seguintes critérios de inclusão: gestação única, idade gestacional no dia da primeira espirometria inferior a 13,86 semanas, ausência de doenças maternas préexistentes, preparação adequada para o teste de espirometria e amostradores passivos individuais (APIs) adequados para análise. Os critérios de exclusão foram a mudança de endereço, o aborto, o teste de espirometria inadequado e desistência de participar do projeto. Os APIs contendo dois filtros de celulose embebidos com solução absorvente para capturar os níveis de NO2 e outros dois filtros embebidos com solução de índigo blue para medir os níveis de O3 foram entregues às gestantes cerca de 12 dias antes da realização do teste de espirometria. Dados do relatório anual da Companhia Ambiental do Estado de São Paulo (CETESB) para o mesmo período dos amostradores passivos, foram utilizados. Para a espirometria, um espirômetro Koko foi utilizado, sendo considerada as duas melhores curvas para avaliar os resultados da função pulmonar. Análise estatística: Foi utilizado o teste Mann-Whitney para grupos independentes e Wilcoxon para os dependentes. Devido à pequena variação na exposição à poluição, a exposição no primeiro trimestre (Q1) e quarto trimestre (Q4) foram comparados para cada poluente em T1 e T3 através da análise nãoparamétrica para medidas repetidas. Resultados: Houve uma redução estatisticamente significativa dos valores absolutos (T1: 3,690 L; T3: 3,475 L) e preditos (T1: 101%, T3: 97,5%) da capacidade vital forçada (CVF), p < 0,0001. E uma redução estatisticamente significativa dos valores absolutos (T1: 3.080 L; T3: 2.950 L) e preditos (T1: 99%, T3: 96%) do volume expiratório forçado no primeiro segundo do procedimento (FEV1), p < 0,0001. A exposição à poluição foi semelhante em ambos os trimestres, exceto para a exposição de NO2 no API, o que foi inferior em T3 (p = 0,001). Independentemente do trimestre (T1 ou T3), o grupo de mulheres do Q4 (T1: 97,5%; T3: 98,5%) teve NO2 estatisticamente maior dos valores do fluxo expiratório forçado de 25 a 75% do procedimento (FEF25-75%) do que o grupo em Q1 (T1: 80%; T3: 92%). O grupo de mulheres do Q1 do NO2 teve um aumento significativo neste parâmetro de T1 a T3 (p = 0,042). Em termos de valores absolutos da relação FEV1/FVC, o grupo de mulheres no Q1 mostrou um aumento estatisticamente significativo neste parâmetro de T1 (0,810 L) para T3 (0,840 L) (p = 0,026). Em T3, os valores absolutos e relativos da CVF foram estatisticamente maiores para o grupo de gestantes do Q4 (3,535 L; 100,5%) de NO2 do que para o grupo de gestantes do Q1 (3,345 L; 92%). O grupo de gestantes do Q4 de O3 mostrou o VEF1 estatisticamente maior eno T1 (102,5%) do que no T3 (95,5%) (p < 0,001). Independentemente do trimestre, o grupo de gestantes do Q4 do MP10, teve valores absolutos da CVF (T1: 3.520 L; T3: 3,265 L) e os valores de VEF1 (T1: 2,915 L; T32.840 L) foram estatisticamente menor do que para o grupo em Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0,040; p = 0,035, respectivamente. Valores absolutos e preditos do pico de fluxo expiratório (PEF) em T1 das mulheres do Q4 (5,995 L; 80%) do MP10 foram estatisticamente menores do que para as mulheres no Q1 (6,675 L; 85%) (p = 0,006; p = 0,041 , respectivamente). Mulheres grávidas em Q4 (0,835 L) do MP10 tiveram os valores da relação VEF1/CVF estatisticamente menores valores do que as mulheres do Q1 (0,850 L) (p = 0,029). Conclusão: Exposição a NO2 e O3 foi associada com o aumento de alguns dos parâmetros de espirometria, indicando a presença de uma possível função de defesa pulmonar ou mecanismo compensatório em mulheres grávidas, quando expostos a esses poluentes. O MP10 foi associado com a redução de alguns parâmetros de espirometria durante a gravidez, indicando os efeitos danosos do poluente para a função do pulmão de mulheres grávidas / Introduction - Air pollution can lead to alterations to the respiratory system, particularly among certain groups, such as pregnant women, which are more vulnerable to the effects of air pollutants. Pregnancy is a period involving functional and anatomical changes in a woman\'s body. These changes include pulmonary function, which can be assessed by spirometry, a simple, inexpensive and effective method. Objectives - The aims of this study were to use spirometry to evaluate pulmonary function in pregnant women in the first trimester (T1) and the third trimester (T3) of pregnancy and to analyze the influence of air pollution exposure on the spirometry parameters. Methodology - This study was carried out at the Obstetrics Clinic of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) between May 2011 and August 2013. The following inclusion criteria were applied: singleton pregnancy, 13.86 weeks gestational age at the first spirometry, no preexisting maternal diseases, adequate preparation for the spirometry test and individual passive samplers (IPAs) suitable for analysis. The exclusion criteria were change of address, abortion, inadequate spirometry testing and withdrawal from the project. The exposure to pollutants prior to the spirometry tests was assessed in T1 and T3. The passive samplers containing two cellulose filters soaked with absorbent solution to capture NO2 levels and two other filters soaked with indigo solution to measure O3 levels were provided to the pregnant women roughly 12 days prior to the spirometry test. Data from the environmental Company of São Paulo State (CETESB) annual report for the same period the passive samplers were used. For the spirometry, a Koko spirometer was used, taking the two best curves to assess lung function results. Statistical Analysis - We used Mann- Whitney tests for independent groups and Wilcoxon for the dependent ones. Due to the small variation in the exposure to pollution, exposure in the first quarter (Q1) and fourth quarter (Q4) were compared for each pollutant in T1 and T3 through non-parametrical analysis for repeated measurements. Results - It has been noted a significant statistical reduction of absolute and predicted forced vital capacity (FVC) values (3.690 L; 3.475 L) and forced expiratory volume during the first second of the procedure (FEV1) (3.080 L; 2.950 L) from T1 to T3. Exposure to pollution was similar in both trimesters, except for exposure to NO2 in the passive sampler, which was lower in T3 (p = 0.001). Regardless of the trimester (T1 or T3), the group of pregnant women in Q4 (97.5%; 98.5%) of NO2 had statistically higher predicted forced expiratory values of 25 to 75% of the procedure (FEF25-75%) than the group in Q1 (80%; 92%). Pregnant women in Q1 of NO2 had a significant increase in this parameter from T1 to T3 (p = 0.042). In terms of absolute FEV1/FVC values, pregnant women in Q1 showed a statistically significant rise in this parameter from T1 (0.810 L) to T3 (0,840 L) (p = 0,026). In T3, absolute and predicted FVC values were statistically higher for the group of pregnant women in Q4 (3.535 L; 100.5%) of NO2 than for the group of pregnant women in Q1 (3.345 L; 92%). Pregnant women in Q4 of O3 displayed statistically higher FEV1 values in T1 (102.5%) than in T3 (95.5%) (p < 0.001). Regardless of trimester, for the group of pregnant women in Q4 of MP10, absolute FVC (T1:3 .520 L; T3: 3.265 L) and FEV1 values (T1: 2.915 L; T3: 2.840 L) were statistically lower than for the group in Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0.040; p = 0.035 respectively. Absolute and predicted peak expiratory flow (PEF) in T1 of pregnant women in Q4 (5.995 L; 80%) of MP10 were statistically lower than for the pregnant women in Q1 (6.675 L; 85%) (p = 0.006; p = 0.041, respectively). Pregnant women in Q4 (0.835 L) of MP10 displayed statistically lower absolute FEV1/FVC values than the pregnant women in Q1 (0.850 L) (p = 0.029). Conclusion - Exposure to NO2 and O3 was associated with the increase in some of the spirometry parameters, indicating the presence of a possible lung function defense or compensatory mechanism in pregnant women when exposed to those pollutants. The MP10 was associated with the reduction of some spirometry parameters during pregnancy, indicating the harmful effects of that pollutant to the lung function of pregnant women
|
9 |
Quantificação da carga isquêmica em pacientes com doença coronária avançada sintomática: comparação entre a perfusão miocárdica avaliada por ressonância magnética cardíaca e por cintilografia miocárdica / Ischemic burden in advanced coronary artery disease: comparison between myocardial perfusion by cardiovascular magnetic resonance and single-photon emission computed tomographyThiago Nunes Pereira Leite 16 August 2018 (has links)
Introdução: A quantificação da isquemia miocárdica é um dado de grande auxílio na tomada de decisões clínicas ou intervencionistas no tratamento da doença arterial coronária (DAC) avançada. Dentre os métodos disponíveis para esta finalidade, se destacam a cintilografia de perfusão miocárdica (CPM) e a ressonância magnética cardíaca (RMC), que além de fornecerem informações quanto à alteração de motilidade entre o estresse e o repouso, são capazes de analisar a perfusão miocárdica. Neste estudo, investigamos a correlação e a concordância entre esses dois métodos em pacientes com DAC sintomática e avançada. Métodos e Resultados: Cinquenta e três pacientes com DAC avançada (padrão obstrutivo triarterial) não elegíveis para revascularização completa devido à extensão e caráter difuso das lesões foram submetidos à RMC e à CPM. A maioria (57%) apresentava sintomas limitantes (angina CCS 3 ou 4). Na quantificação da carga isquêmica, o percentual de miocárdio isquêmico total (%Mioisquêmico) foi significativamente maior na RMC do que na CPM (25,3±13,7% vs. 20,5±13,5%, respectivamente; P = 0,02). A RMC identificou baixa carga isquêmica em apenas 15% dos pacientes, enquanto pela CPM 53% dos pacientes foram assim classificados. Foram encontradas correlações fracas entre os métodos para o %Miofixo, no %Mioestresse e %Mioisquêmico (coeficiente de Spearman variando de 0,06 a 0,54), assim como uma fraca concordância (kappa de 0,11 e bias elavado de 9,3 para %Mioisquêmico). De um total de 159 territórios coronarianos, 18 (11%) apresentaram grandes discordâncias (%Mioisquêmico pela CPM < 10% e > 20% pela RMC) em regiões do ventrículo esquerdo com alta probabilidade pré-teste de possuírem isquemia importante (miocárdio viável em território irrigado por artéria coronária ocluída cronicamente). Conclusão: A quantificação da carga isquêmica estresse-induzida avaliada pela CPM e pela RMC possui fraca correlação e concordância em pacientes com DAC avançada e complexa, com a RMC demonstrando uma maior carga isquêmica do ventrículo esquerdo, principalmente nas regiões com infarto prévio / Introduction: The quantification of myocardial ischemia is a key element in the decision-making process in patients with advanced coronary artery disease (CAD). Single-photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) are non-invasive tools for myocardial perfusion assessment. We investigated the correlation and agreement between these two methods in patients with symptomatic and complex CAD. Methods and Results: Fifty-three patients with advanced CAD (multivessel obstructive disease) not eligible for complete revascularization due the extension and diffuseness of the disease underwent both CMR and SPECT. The majority (57%) presented limiting symptoms (angina CCS 3 or 4). The quantification of the ischemic burden revealed that the mean percentage of total ischemic myocardium (%Myoischemic) was significantly higher as assessed by CMR compared with by SPECT (25.3±13.7% vs. 20.5±13.5%, respectively; P = 0.02). There were no significant correlations between CMR and SPECT regarding %Myostress (r = 0.23, p = 0.09), fixed (r = 0.20, p = 0.14), or ischemic (r = 0.11, p = 0.44). While SPECT classified 28 patients (53%) as having low ischemic burden (%Myoischemic < 10%), CMR classified only 8 patients (15%) in this category. Poor correlations between the two methods were found for %Myostress, %Myoischemic, and %Myofixed (Spearman\'s rho ranging from 0.06 to 0.54), depicting also slight agreement (kappa of 0.11 and bias as high as 9.3% for %Myoischemic). On a per-segment-based analysis, 18 coronary territories (11%) of the total 159, presented highly disagreements (%Myoischemic by SPECT < 10% and > 20% by CMR) in LV regions likely to have severe ischemia (viable myocardium supplied by chronically occluded vessels. Conclusion: The quantification of inducible myocardial ischemia by SPECT and CMR disagrees in patients with advanced and complex CAD, with CMR displaying greater left ventricular ischemic burden, particularly in patients with a previous myocardial infarction
|
10 |
Avaliação da sensibilidade cutânea em pés de pacientes diabéticos através do Pressure Specified Sensory Device TM / Evaluation of cutaneous sensibility threshold on the feet of diabetic patients with the Pressure Specified Sensory Device(TM)Viviane Fernandes de Carvalho 04 March 2008 (has links)
A neuropatia diabética causa diminuição ou perda da sensibilidade protetora do pé, tornando-o mais vulnerável ao trauma mecânico e térmico. A profilaxia das complicações neuropáticas tem início pela identificação da perda de sensibilidade e, portanto, do comprometimento neurológico. O Pressure Specified Sensory Device(TM) (PSSD) é um equipamento desenvolvido para quantificar o limiar de pressão, aplicada sobre a pele, necessária para que o paciente perceba o estímulo provocado por: um ponto estático, um ponto em movimento, dois pontos estáticos e dois pontos em movimento. Denominamos grupo estudo, aos trinta e quatro pacientes diabéticos do tipo 2, sem história prévia de feridas e/ou amputações nos pés que foram submetidos à avaliação de sensibilidade cutânea utilizando-se o PSSD(TM). Foram realizados testes nos territórios cutâneos dos nervos fibular profundo, plantar medial e ramo calcâneo do nervo tibial posterior. Estímulos foram provocados segundo as modalidades: um ponto estático (1 PE), um ponto em movimento (1 PD), dois pontos estáticos (2 PE) e dois pontos em movimento (2 PD), para as duas últimas modalidades. Previamente às modalidades 2PE e 2PD determinou-se o limiar de discriminação entre dois pontos estáticos (D2PE) e em movimento (D2PD). Foram realizados apenas no grupo estudo, testes com o monofilamento de Semmes-Weisntein nº 5,07 (MSW) e com o diapasão de 128 Hz. Vinte e oito pacientes não-diabéticos, submetidos aos mesmos testes, formaram o grupo controle. Para os limiares de sensibilidade, encontramos valores superiores no grupo estudo (p < 0,05). Ao compararmos os limiares de sensibilidade alcançados pelos pacientes diabéticos sensíveis e não sensíveis ao estímulo promovido pelo MSW nº 5,07 verificamos que o p-valor variou entre 0,018 < p < 0,113 para 1 PE e 0,002 < p < 0,083 para 2 PE, conforme o território cutâneo estudado. Na comparação dos limiares de sensibilidade da modalidade 1 PD entre diabéticos sensíveis e insensíveis à vibração do diapasão de 128 Hz, as diferenças não foram estatisticamente significantes (p = 0,183). Os resultados obtidos nos permitiram sugerir que o dispositivo PSSD(TM) seja utilizado como forma de acompanhamento do comprometimento da fibra nervosa. / Neuropathy is a severe progressive loss of protective sensation on the feet, making the patient more vulnerable to mechanical trauma and consequently more suitable to the development of chronic wounds, major distortion of the foot bone architecture and eventually to limb amputation. Prophylaxis should be enforced to avoid foot ulceration and for that, evaluation of the degree of loss of sensation on the skin is essential. The PSSD (Pressure Specified Sensory Device(TM)) was developed in order to quantify the threshold of pressure applied to the skin that could be recognized as positive by the patient. Pressure of one or two points is tested both statically and with movement, thus assessing the function of fast and slow response nerve fibers. Threshold of two-point discrimination was also measured in mm. Thirty four (n = 34) diabetic patients, type II, with no previous history of wounds on the lower extremity were studied using the tests, one point static (1PE), one point moving (1PD) and two points static (2 PE), and moving (2 PD) on the cutaneous territory of the fibular nerve and posterior tibial nerve (two territories - medial plantar and calcaneous nerves). The control group (28 non diabetic patients) was assessed by the same exams and the results were compared. In the diabetic group the cutaneous territories were also evaluated using the conventional Semmes-Weinstein filament nº 5,07 e vibrometer of the 128 Hz. Altered values were observed for the static and dynamic tests over the three studied nerve territories. The differences were statically significant (p < 0,05). Comparing the threshold of sensibility between sensitive and non sensitive diabetic patients to MSW nº 5,07 test, we observed that p-value range was 0,018 0,113 when 1PE test was applied, and 0,002 0,083 when 2PE test was applied, according to the cutaneous territories evaluated. Numeric quantification of the threshold of pressure allows us to determine the status of the fiber/receptor structures as well as the functional deficit of nerve fibers. Our findings suggest that PSSD(TM) is an adjuvant tool to evaluate the degree of loss of sensation on the skin.
|
Page generated in 0.0889 seconds