Alternativt material i behållare för konstgödselrampspridare : Förarbete för prototyp / Alternative material in container for fertilizer spreader : Preparatory work for prototype

Lindell Wallgren, Ida January 2015 (has links)
Överums Bruk AB tillverkar jordbruksmaskiner såsom konstgödselrampspridaren Wing Jet. Wing Jet har idag en konstgödselbehållare tillverkad i rostfritt stål och företaget önskar veta om det är möjligt och lämpligt att tillverka behållaren i plast/plastkomposit i syfte att minska produktionskostnaden av behållaren samt dess vikt. Detta arbete är begränsat till behållaren, övriga konstgödselspridaren ska inte behöva några förändringar för att byta den rostfria behållaren till en i plast/plastkomposit och det ingår inte i arbetet att tillverka en prototyp. Rotationsgjutning och handuppläggningsmetoden (glasfiberarmering) är två tillverkningsmetoder som är lämpliga att använda vid tillverkning av så stora objekt. Simuleringar av en rotationsgjuten behållare i materialet högdensitetspolyeten (HDPE) i programmet SolidWorks Simulation Standard resulterar i maximala effektivspänningar strax över materialets brottgräns då ett tryck baserat på ekvationer från europastandarden Eurocode 1-4: 2006 (Silor) anläggs på behållarens insida. Det uppstår dock deformationer på flera centimeter vilket i sig inte är ett problem, men det gör behållaren mindre estetiskt tilltalande (släta sidor buktar utåt). Behållarens vikt minskar till ca hälften av dagens och den är billigare att tillverka. Material och tillverkningsmetoder som resulterar i en behållare med högre styvhet i avseende att minska deformationen är rekommenderat att undersökas som vidare arbete. Exempel på detta är glasfiberarmerad polyester eller epoxi och ”sandwich”-konstruktioner. En sandwich-konstruktion består av två (eller fler) lager av ett material med en kärna, av t.ex. ett skum, mellan. Genomförda simuleringar är linjärelastiska, medan plaster allmänt är olinjära, så olinjära simuleringar bör genomföras innan prototyp tillverkas. / Överums Bruk AB manufactures agricultural equipment such as the fertilizer spreader Wing Jet. Wing Jet has a container which today is manufactured from stainless steel and the company wishes to know if it is possible and suitable to manufacture the container from plastic/plastic composite with the purpose to lessen the containers production costs and weight. This work is limited to the container, the rest of the fertilizer spreader should not need any changes to switch the stainless steel container for a plastic/plastic composite one and the work does not include manufacturing a prototype. Rotational molding and hand lay-up (glass-fibre reinforcement) are two manufacturing processes which are suitable to use when manufacturing such large objects. Simulations of a rotational molded container in the material high density polyethylene (HDPE) in the program SolidWorks Simulation Standard results in maximum effective stresses just above the materials tensile strength when a pressure based on equations from the European standard Eurocode 1-4: 2006 (Silos and Tanks) are applied on the containers inside. However, deformations of several centimeters occurs which in itself is not a problem, though it makes the container less esthetically appealing (smooth sides bulges outward). The containers weight decreases to approximately half of that of today and it is cheaper to manufacture. Materials and manufacturing processes which results in a container with higher stiffness in the purpose of lessen the deformation is recommended to investigate as future work. Examples of this are glass-fibre reinforced polyester or epoxy and “sandwich”-constructions. A sandwich-construction is comprised of two (or more) layers of a material with a core, of e.g. foam, between. The simulations carried out are linear elastic, whereas plastics generally are non-linear, so non-linear simulations should be carried out before a prototype in manufactured.
12

Compression perpendicular to grain in timber – Bearing strength for a sill plate / Tryck vinkelrätt fibrerna hos trä – Sylltryck

Kathem, Ali, Hussain, Tajdar, Kamali, Arman January 2014 (has links)
Timber is widely used in the construction industry, because of its availability and good properties. The compressive strength perpendicular to grain (bearing strength) is one property of wood which is important for structural design. The bearing strength is important for the behavior of the structure in all contact points between wooden members. The calculations models for bearing strength have been a subject of discussion for many years and the different building codes in Europe has treated it differently during the years. The aim of this thesis was to compare different calculations models for bearing strength with the results of an experimental study. In this study the bearing strength for a fully supported beam loaded with a point load was studied. Two different loading lengths were studied as well as loading in a point in the middle of the beam, at the edge of the beam and at a distance of 10 mm between the edge and the loading point. The loading was made with a steel stud. Calculations were also performed according to the following standards; Eurocode 5 (EN1995-1-1:2004) before and after amendment, the German Code (DIN 1052:2004), the Italian Code (CNR-DT 206:2006) and two versions of the Swedish Code (BKR). The results showed that the results from the new version of Eurocode 5 agreed best with the experimental results. The tested results, however, were lower than the values calculated using Eurocode (and all the other codes); this might be explained by the hard loading conditions using a steel stud instead of a wood stud.
13

Underlag för fördelaktig upphängning av kylvattenledningar i en äldre byggnad / Basis for advantageous suspension for water cooling pipes in an older building

Andersson, Alexander, Bergman, Carl January 2014 (has links)
Arbetet redovisar möjligheterna att hänga upp tyngre vattenledningar i en äldre industrilokal där en äldre byggnadsstandard användes vid uppförandet. Ett flertal alternativ har tagits fram och där de mest lämpade har arbetats vidare genom att jämföra fördelar och nackdelar.
14

Strength analysis of load-bearingstructures according to Eurocode : Continuous kiln TC / Hållfasthetsanalys av bärande konstruktion enligt Eurocode : Kanaltork TC

Söderström, Simon January 2021 (has links)
In this work, the load-bearing structure of a wood kiln is analyzed with the finite element method (FEM). The analysis is done with the program Inventor Nastran and consist of a linear stress and buckling analysis. The dimensions of the kiln can vary, therefore reference values are used where it is 32 m long, 12 m high and 10.5 m wide. The kiln consists of different zones that are identical to each other, these zones are separated with load-bearing structures. This structure is made up of stainless steel sheet metal with a thickness of 2-3 mm. To stabilize the kiln against wind forces, a support structure is attached on the side of the load-bearing structure.  The requirements for the strength calculations have increased in the industry. The goal is to provide a FEM model that can perform and get a realistic result. This would also lead to get a better picture of whether there are any critical areas or parts and how important the support structure is for the stability of the kiln.  A large model requires simplifications to reduce the size of the model and enable it to carry out the analysis. This means the elimination of non-structure components, symmetry by a plane, define contact surfaces, and mesh convergence. The loads acting on the kiln consisting of wind and snow are according to the Eurocode.  It is proved possible to develop a model that could perform a realistic analysis using these simplifications. A large model consisting of many parts can create uncertainty in the analysis. Therefore, some parts need to be examined more carefully and some improvements in the FEM model is required.  The weakest components in the model could be located where some reinforcement may be needed to secure the structural strength. The importance of the support structure function to strengthen the load-bearing structure of the kiln could be proven.
15

Designing Eccentrically Loaded Concrete Encased Steel Composite Columns to Eurocode 4 using Second-Order Analysis

Lam, Dennis January 2011 (has links)
No
16

Designing composite beams with precast hollowcore slabs to Eurocode 4

Lam, Dennis January 2007 (has links)
no / The design of multi-storey buildings in the UK, in the past, considered steel and concrete structures in isolation. Today, designers utilize the combined properties of steel and concrete in the form of composite or hybrid structures as a more attractive efficient alternative. Designers of steel structures acknowledge that the presence of concrete slabs may be designed compositely with steel beams in order to increase both flexural strength and stiffness at virtually no extra cost, except for the headed shear studs. The use of composite construction with precast hollowcore slabs has become one of the most popular construction methods in the UK. Currently, design of composite construction is covered by BS5950, Part 3, but will soon be replaced by the new European Standard, Eurocode 4. However, design of composite construction with precast hollowcore slabs is currently outside the provisions of this new code. In this paper, an overview of the Eurocode 4 structure and its contents are first presented and some of the particular issues that affect this new form of construction will be given. Design guidance using the Eurocode methodology will also be presented.
17

Resistance of Members to Flexural Buckling According to Eurocode 3 : - Focus on Imperfections

Hirani, Aliasgar, John, George, Mupeta, Henry January 2015 (has links)
This work focuses mainly on the resistance of members to flexural buckling according to Eurocode 3. The work provides the mathematical backgrounds to the equations and buckling curves presented in Eurocode 3. The work also, attempts to reveal how different imperfections influence the flexural buckling resistance which is demonstrated through Finite Element (FE) simulations. The work presents modeling and analysis on a steel column in ABAQUS 6.14. Linear and non-linear buckling analyses of the steel column, with the influence of imperfections, are implemented in this work. Specifically, the imperfections considered in this study are material plasticity, initial bow and residual stress. The influence of initial bow imperfection of 0.1% of the length of the column considering flexural buckling was found to be 45.28% of the Euler buckling load. The influence of residual stresses, with a magnitude of maximum about 13% in the flange and 35% in the web, of the yielding strength, on flexural buckling is about 31.9% of the design Euler buckling load. The combined effect of residual stress and initial bow imperfection on flexural buckling is about 45.34% of the design Euler buckling load.
18

Observationsmetodens tillämpning på inläckande grundvatten i bergtunnlar Fallstudie: Norra länken i Stockholm

Spross, Johan January 2011 (has links)
På senare år har samhället ställt allt högre miljökrav, när nya tunnlar ska anläggas. Ett område där kraven har höjts, är dräneringen av grundvatten på grund av inläckage till tunneln. Detta kan ge upphov till bland annat sinande brunnar, sättningsskador på byggnader samt påverkan på vegetation och naturmiljö. För att minimera problemen genomförs ett omfattande tät­ningsarbete i tunneln. Fullständig täthet uppnås dock sällan. Därför måste mätningar och kontroller utföras, både av grundvattennivåerna i närområdet och av det inläckande grund­vattenflödet i tunneln. Eftersom hanteringen av grundvattenfrågan länge varit nedprioriterad i branschen, behöver både planeringen och utförandet av mätningarna utvecklas, för att kunna möta samhällets allt hårdare miljökrav på området. Syftet med det här examensarbetet var att undersöka hur ramverket till den så kallade obser­vationsmetoden, kan användas till hanteringen av grundvatteninläckage vid tunnelbyggnad i berg. I denna metod förbereder man i projekteringen en preliminär design av konstruktionen. Samtidigt planerar man för åtgärder att sätta in, om mätningar (observationer) under bygg­tiden indikerar att designen behöver förändras. Därmed kan konstruktionen under projektets utförande anpassas till de faktiska förhållandena i marken. För att undersöka om observa­tionsmetoden är tillämpbar på hanteringen av inläckande grundvatten, studerades tunnel­projektet Norra länken i Stockholm. En jämförelse gjordes mellan hur grundvattenfrågan löstes i detta projekt och hur observationsmetoden definieras i Eurokoden samt i det till­hörande svenska tillämpningsdokumentet för geoteknik. Resultatet av den jämförande studien visade att utförandet i Norra länken till stor del överensstämde med hur observationsmetoden definieras i Eurokoden och med skrivningarna i tillämpningsdokumentet. Den ena skillnaden gällde mätanordningarnas tillförlitlighet. Den andra låg i hur det visas att det är tillräckligt hög sannolikhet, att den preliminära designen kommer att klara uppsatta krav. Med utveckling av dessa områden, borde det vara möjligt att fullt ut tillämpa observationsmetodens ramverk på hanteringen av grundvatteninläckage. Det visades dock att Eurokodens observationsmetod inte nödvändigtvis erbjuder den bästa lös­ningen, utan att varianter på denna också kan utgöra fullgoda alternativ. Examensarbetet visade också på några områden där förändringar kan göras, för att ge en bättre hantering av grundvattenfrågan i framtiden. Exempelvis borde bergtekniker komma in tidigt i projekteringen, för att göra kunskapsbilden mer komplett när de hydrogeologiska modellerna tas fram. Det borde också utredas om det finns bättre alternativ till injektering, när det är stor risk att detta inte är tillräckligt för att ge en tät konstruktion. Slutligen konstaterades det att det vore gynnsamt för alla inblandade parter om grundvatten­frågan hanterades på ett mer konsekvent sätt, eftersom detta skulle bidra till en ökad förut­sägbarhet och överskådlighet. Att följa det ramverk som Eurokodens observationsmetod erbjuder, är ett sätt att göra detta.
19

Behaviour and structural design of concrete structures exposed to fire

De Wit, Annelies January 2011 (has links)
Concrete has an excellent intrinsic behaviour when exposed to fire, especially when compared to other building materials. However, its fire resistance should not be taken for granted and a proper structural fire design is certainly necessary. This design is based on the understanding of both the material and the structural behaviour of concrete exposed to fire. A number of complex physicochemical reactions occur when concrete is heated, causing mechanical properties as strength and stiffness to deteriorate. Furthermore, the phenomenon of spalling causes pieces of concrete to break off from the surface, reducing the cross-section of an element and possibly exposing the reinforcing to the high temperatures. Spalling can be highly dangerous and is most common in high strength concrete. However, its mechanism is still not fully understood. The Eurocode provides a number of procedures in order to design concrete structures for the fire situation, both prescriptive as performance based. However, of the latter, only the basic principles are given and several gaps still need to be filled through research. Thus in practical design, either tabulated data or a simplified calculation method is used. In many cases, these design methods fail to predict the true behaviour of concrete structures in real fires. Firstly, the standard heating curve is not able to represent the wide variety of realistic fires. Furthermore, design should investigate the behaviour of the complete structure, including alternative failure modes, whereas member analysis ignores effects as incompatible thermal expansions which can cause high thermal stresses. Although a lot of research has been performed already, more in-depth study is needed. Several elements of the behaviour of heated concrete still need to be researched. A systematic study of the effects of realistic thermal exposures is needed and a lot more work is required in order to unravel the mystery of spalling. The study of the response of complete concrete structures presents another challenge, requiring large-scale fire tests. The goal is to develop a concrete model that reflects the true behaviour of concrete structures exposed to fire. This model should incorporate the fully coupled hygro-thermal-mechanical behaviour combined with a sophisticated structural analysis, including the effect of transient strain.
20

Vertikala deformationer

Hvit, Erik January 2020 (has links)
Eurokoderna som tillsammans med EKS (Boverkets konstruktionsregler), utgör svenska normer för verifiering av bärförmåga, stadga och beständighet kan ibland vara svåra och tidsödande att tolka och tillämpa i konstruktionsarbetet. I bruksgränstillstånd finns oftast inte krav kvantifierade i eurokoden utan det är byggherrens eller konstruktörens ansvar att formulera dimensioneringskriterier för till exempel deformationer. Denna brist på tydliga krav och definitioner gör det svårt att få en samlad bild och tolkningar och kriterier tenderar till att bli individuella. Hur deformationsgränser och lastfall tolkas och tillämpas påverkar hur byggnadsdelar dimensioneras och utformas och därmed även materialåtgång, kostnad och miljö.   Den här studien är gjord för att effektivisera hur AFRY arbetar med eurokoderna med avseende på bruksgränstillstånd och framför allt vertikala stomdeformationer. Studien visar även hur materialanvändningen påverkas av olika deformationskriterier och lastfall. För att kunna visa detta har några vanligt förekommande konstruktionslösningar studerats.   Det som framkommit är att frånvarandet av deformationsgränser i de svenska eurokoderna är en brist som borde åtgärdas och kanske borde vi göra som andra länder som har med deformationsgränser i den generella delen av eurokoden. Eurokoderna kan även vara krångliga att läsa, och det är lätt att tappa helhetsbilden när informationen som eftersöks finns i olika stycken och eurokoder.   Det har även framkommit att materialåtgången kan vara så stor som 66 procent beroende av hur eurokoderna tolkas och vilka deformationskrav som används. Det är dock en siffra som kan ha stora variationer beroende på konstruktionslösning och material, men resultatet ger dock en fingervisning på hur det kan se ut.