• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 418
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 435
  • 211
  • 109
  • 105
  • 104
  • 88
  • 84
  • 78
  • 71
  • 65
  • 61
  • 52
  • 51
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Redução da concentração de herbicidas em águas por filtração em multiplas etapas seguida de coluna de carvão ativado de babaçu e obtenção de adsorventes a partir de bagaço de cana e casca de Moringa oleífera / Reducing of herbicides concentration in water by filtration in multiple steps followed by activated carbon colunns babassu and getting adsorbents from sugar cane bagasse and shell of Moringa oleifera

Zoratto, Ana Cristina, 1980- 26 August 2018 (has links)
Orientador: José Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T20:17:39Z (GMT). No. of bitstreams: 1 Zoratto_AnaCristina_D.pdf: 5806599 bytes, checksum: f38244534c21b9c49d6636c8f7b7e0c8 (MD5) Previous issue date: 2014 / Resumo: Aumento da produtividade e da área plantada de cana-de-açúcar no país tem sido acompanhada por uma utilização intensiva de herbicidas, que representam os produtos mais amplamente encontrados em recursos hídricos em todo o mundo. Por isso, a preocupação com a contaminação dos recursos hídricos ea necessidade de tratamento abrange não só os grandes centros urbanos, mas também pequenas comunidades e nas zonas rurais, que na maioria das vezes usam a água para fins de abastecimento sem qualquer forma de treatment.For esta razão, o presente estudo teve como objetivo avaliar a eficiência na redução herbicidas: atrazine, hexazinone e tebuthiuron em água Sistema de Tratamento através de filtragem em várias fases - FiME, seguido por colunas (filtros) de babaçu carvão ativado granular com taxas de filtração diferentes, acrescentando que a produção de carvões activados de agrícolas pelos produtos; bagaço de cana-de-açúcar e casca de pod MoringaOleifera, com área de superfície elevada e micro porosidade, tornando-se uma alternativa de tratamento de água em comunidades rurais. A avaliação herbicida de redução em FiME foi realizada através de três tratamentos, com diferentes filtros de revascularização miocárdica instalados na extremidade do sistema de filtragem. As taxas de filtração nesta etapa variou entre 10,8 e 220,6 m3.m-2.d-1. Os valores obtidos nas etapas de PF e PL, mostram que não existe uma redução significativa na concentração de herbicida, e que FCAGB com HDT mais elevada e mais baixa taxa de filtração exibem as mais altas eficiências em reduzir a herbicidas atrazina, hexazinona e tebutiuron. A produtividade resuIncreased ea área plantada de cana-de-açúcar no país tem sido acompanhada por uma utilização intensiva de herbicidas, que representam os produtos mais amplamente encontrados em recursos hídricos em todo o mundo. Por isso, a preocupação com a contaminação dos recursos hídricos ea necessidade de tratamento abrange não só os grandes centros urbanos, mas também pequenas comunidades e nas zonas rurais, que na maioria das vezes usam a água para fins de abastecimento sem qualquer forma de treatment.For esta razão, o presente estudo teve como objetivo avaliar a eficiência na redução herbicidas: atrazine, hexazinone e tebuthiuron em água Sistema de Tratamento através de filtragem em várias fases - FiME, seguido por colunas (filtros) de babaçu carvão ativado granular com taxas de filtração diferentes, acrescentando que a produção de carvões activados de agrícolas pelos produtos; bagaço de cana-de-açúcar e casca de pod MoringaOleifera, com área de superfície elevada e micro porosidade, tornando-se uma alternativa de tratamento de água em comunidades rurais. A avaliação herbicida de redução em FiME foi realizada através de três tratamentos, com diferentes filtros de revascularização miocárdica instalados na extremidade do sistema de filtragem. As taxas de filtração nesta etapa variou entre 10,8 e 220,6 m3.m-2.d-1. Os valores obtidos nas etapas de PF e PL, mostram que não existe uma redução significativa na concentração de herbicida, e que FCAGB com HDT mais elevada e mais baixa taxa de filtração exibem as mais altas eficiências em reduzir a herbicidas atrazina, hexazinona e tebutiuron. Os resultados mostram que a adição de área de superfície desenvolvida do carbono activado, outros factores que influenciam o processo de adsorção, tais como a solubilidade do adsorbato, carga de superfície CA, pH e temperatura da solução. Por ter uma maior solubilidade e menor carácter hidrofóbico, herbicida atrazina era o herbicida mais adsorvido pela A revascularização miocárdica durante os treatments.lts mostram que a adição de área de superfície desenvolvida do carbono activado, outros factores que influenciam o processo de adsorção, tais como a solubilidade do adsorbato , carga de superfície CA, pH e temperatura da solução. Por ter baixa solubilidade e maior caráter hidrofóbico, herbicida atrazina foi o herbicida mais adsorvido pela revascularização miocárdica durante os tratamentos / Abstract: Abstract: Increased productivity and the acreage of cane sugar in the country has been accompanied by intensive use of herbicides, which represent the most widely products found in water resources worldwide. Therefore, the concern about contamination of water resources and the need for treatment not only covers major urban centers, but also small communities and rural areas, which most often use water for supply purposes without any form of treatment.For this reason, the present study aimed to evaluate the efficiency in reducing herbicides: atrazine, hexazinone and tebuthiuron in Water Treatment System through multi-stage filtration - FiME, followed by columns (filters) of babassu granular activated carbon with different filtration rates, adding the production of activated carbons of agricultural by products; bagasse from sugar cane and pod shell of MoringaOleifera, with high surface area and micro porosity, becoming an alternative water treatment in rural communities. The evaluation of herbicidal reduction into FiME was performed through three treatments, with different filters of CAGB installed at the end of the filtration system. The filtration rates in this step varied between 10.8 and 220.6 m3.m-2.d-1. The values obtained on the steps of PF and PL, show that there is no significant reduction in herbicide concentration, and that FCAGB with higher HDT and lower filtration rate exhibit the highest efficiencies in reducing the herbicides atrazine, hexazinone and tebuthiuron. The results show that addition of the developed surface area of the activated carbon, other factors influence the adsorption process, such as solubility of the adsorbate, CA surface charge, pH and temperature of the solution. By having lower solubility and greater hydrophobic character, atrazine herbicide was the most adsorbed herbicide by the CAGB during the treatments / Doutorado / Saneamento e Ambiente / Doutora em Engenharia Civil
252

Comparação entre os meios filtrantes areia e nãotecido sintético na eficiência da filtração lenta para tratamento de água / Comparision between sand filter media and non-woven synthetic fabric in the efficicency of slow filtration as water treatment

Santos, Flavia Ferreira de Souza dos, 1985- 29 August 2018 (has links)
Orientadores: José Euclides Stipp Paterniani, Túlio Assunção Pires Ribeiro / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-29T00:00:03Z (GMT). No. of bitstreams: 1 Santos_FlaviaFerreiradeSouzados_D.pdf: 6754875 bytes, checksum: 9a804a4e184846e60d2063d6b1aa1326 (MD5) Previous issue date: 2015 / Resumo: O nãotecido sintético é um material de fácil obtenção e baixo custo, cujo uso na filtração lenta juntamente com areia acarretou em resultados satisfatórios, em termos de qualidade de água produzida e facilidade de operação. Esta pesquisa teve como objetivo avaliar o desempenho de um filtro lento com meio filtrante constituído exclusivamente por nãotecido sintético em diferentes espessuras e compará-lo ao desempenho de um filtro lento de areia tradicional. Construiu-se um sistema piloto de filtração em que os dois filtros lentos operavam em paralelo sob influência de três taxas de filtração (3, 6 e 9 m3.m-2.dia-1). No decorrer das carreiras de filtração foram monitorados a evolução da perda de carga de cada filtro, os parâmetros físico-químicos e bacteriológicos da água bruta e água tratada pelo filtro de areia e por cada uma das 12 espessuras (entre 1 e 40 cm) do filtro de nãotecido. O filtro lento de nãotecido proporcionou carreiras de longa duração, quando comparado ao filtro de areia, além de reduzir a frequência e a complexidade do processo de limpeza do filtro. A formação da schmutzdecke foi observada na camada superficial do filtro de nãotecido, o qual teve período de amadurecimento semelhante ao filtro de areia, aproximadamente 15 dias. O desempenho satisfatório do filtro lento de nãotecido abrangeu as três taxas de filtração avaliadas. Em termos de remoção de cor aparente e turbidez da água bruta, atendeu os padrões de potabilidade de água designados pela legislação vigente. E, em termos de remoção de bactérias heterotróficas, coliformes totais e E. coli, o filtro de nãotecido alcançou eficiência superior a 99,5%, estatisticamente similar ao filtro lento de areia. Os resultados obtidos indicam que a espessura ótima de nãotecido sintético para remoção de cor aparente e turbidez da água seria de 25 cm, e sugerem que a espessura de 15 cm de nãotecido seria suficiente para remoção de bactérias, com possibilidade de emprego de taxa de filtração considerada elevada para o tratamento por filtração lenta (9 m3.m-2.dia-1). Desta forma, concluiu-se que o meio filtrante constituído exclusivamente por nãotecido sintético de 25 cm de espessura tem potencial para substituir a areia no tratamento de água por filtração lenta, uma vez que obteve desempenho similar ao filtro lento de areia, além de simplificar os procedimentos operacionais e de manutenção do filtro / Abstract: Non-woven synthetic fabric is an easily available and low-cost material which has brought satisfactory results in terms of both the quality of produced water and its operational value. The aim of this research is to assess the performance of a slow filter made up exclusively of non-woven synthetic fabrics of a number of different thicknesses and to compare it to that of a traditional sand filter. A pilot filtering system was built where the two slow filters operate in a parallel way under the influence of three filtering rates (3, 6 and 9 m3.m-2.d-1). Along the filtering runs the evolution of the headloss and the physical-chemical and bacteriological parameters of both raw water and water treated through the 12 thicknesses (ranging from 1 to 40 cm) of non-woven were monitored as well as that filtered through sand. The slow non-woven filter yielded long-term runs when compared to the sand filter, as well as reducing the frequency and complexity of the filter¿s cleaning process. The formation of schmutzdecke was observed on the superficial layer of non-woven filter, a process which had a similar maturing period to that of the sand filter, approximately 15 days. The satisfactory performance of the slow non-woven synthetic fabric filter covered all three filtering rates. In terms of the removal of apparent color and turbidity of raw water it met the drinkability standards set by the existing legislation. In terms of the removal of heterotrophic bacteria, total coliform and E. coli the non-woven filter obtained an efficiency level above 99,5%, statistically similar to the slow sand filter. The results indicate the optimal thickness of non-woven synthetic fabric for apparent colour and turbidity removal to be 25 cm, and suggest that a 15cm thickness would be enough to remove, with the possibility of using filtering rates considered elevated by slow filtering treatment standards (9 m3.m-2.d-1). Therefore, it concludes that the filter medium constituted exclusively of 25-cm-thick non-woven synthetic fabric has the potential to substitute sand in slow-filtering water treatment once it has obtained similar performance to the slow sand filter / Doutorado / Agua e Solo / Doutora em Engenharia Agrícola
253

Efeitos da suplementação de creatina sobre a função renal de praticantes de treinamento de força: um estudo randomizado, duplo-cego, controlado por placebo / Effects of creatine supplementation on renal function of practitioners of strength training: a randomized, double-blind, placebo controlled study

Rebeca Lugaresi Anadon Refusta dos Santos Netto 08 August 2013 (has links)
Os efeitos da suplementação de creatina sobre a função renal são debatidos intensamente na literatura científica. Os poucos trabalhos sobre o tema envolvendo humanos têm sido severamente criticados por apresentarem ausência de randomização, dosagens não uniformes de creatina, baixo poder estatístico e, sobretudo, ausência de marcadores padrão-ouro de função renal. Além disso, embora tenhamos mostrado recentemente que a suplementação de creatina não prejudica a função renal em sujeitos submetidos a treinamento aeróbio, a natureza desse tipo de atividade, bem como o habitual consumo de proteína dessa amostra, não permite que generalizemos nossos achados à população que mais utiliza creatina: praticantes de treinamento de força sob dietas ricas em proteína. Desta forma, foi conduzido um ensaio randomizado, duplo-cego, controlado por placebo, com o objetivo de investigar os efeitos da suplementação de creatina e sua possível interação com o alto consumo de proteínas sobre a função renal, em praticantes de treinamento de força. Os sujeitos foram divididos aleatoriamente em 2 grupos: a) suplementação de creatina (20g/dia durante cinco dias e 5g/dia até o término do estudo) e b) placebo (dextrose). No período basal e após 12 e 24 semanas, os sujeitos tiveram acompanhamento do consumo alimentar, e foram analisados o clearance de 51Cr-EDTA, creatinina sérica, sódio e potássio séricos e urinários e microalbuminúria. Não foram encontradas diferenças significativas nas variáveis analisadas após 12 e 24 semanas. Demonstrando assim, a ausência de alteração da função renal decorrente da suplementação de creatina, em praticantes de treinamento de força recreacionais com consumo proteico >=1,2g/kg peso/dia / The effects of creatine supplementation on renal function are discussed extensively in the literature. Few studies on the topic involving humans have been severely criticized because of the absence of randomization, non-uniform doses of creatine, low statistical power and, above all, the absence of a gold standard markers of renal function. Furthermore, although we have recently shown that creatine supplementation does not impair renal function in subjects undergoing aerobic training, the nature of this type of activity, as well as the usual protein intake in this sample does not allow generalization of our findings to the population who consume creatine: practitioners of strength training with a high protein intake. Thus, we conducted a randomized, double-blind, placebo-controlled study, in order to investigate the effects of creatine supplementation and its possible interaction with high protein intake on renal function in practicioners of strength training. The subjects were randomly assigned to 2 groups: a) creatine supplementation (20g/day during five days and 5g/day until the end of the study) and b) placebo (dextrose). At baseline and after 12 and 24 weeks, food intake, 51Cr-EDTA clearance, serum creatinine, sodium and potassium serum and urinary microalbuminuria was assessed. No significant differences were observed throughout the trial. Demonstrating that creatine supplementation on practitioners of strength training with high protein intake does not harm renal function
254

Desempenho de sistemas de reatores anaeróbios e aeróbio na remoção de coliformes e ovos de helmintos de águas residuárias de suinocultura /

Sylvestre, Silvia Helena Zacarias. January 2013 (has links)
Orientador: Roberto Alves de Oliveira / Banca: Ruben Pablo Schocken Iturrino / Banca: Giovana Tommaso / Resumo: No presente trabalho avaliou-se o desempenho de dois sistemas de tratamento na redução de indicadores de contaminação biológica em água residuária de suinocultura. O sistema I foi constituído por dois reatores anaeróbios de fluxo ascendente com manta de lodo (UASB), com volumes de 510 e 209 L, instalados em série e o sistema II foi constituído por reator UASB, filtro anaeróbio, filtro biológico percolador e decantador, instalados em série, com volumes de 300, 190, 250 e 150 L, respectivamente. Os tempos de detenção hidráulica (TDH) aplicados nos primeiros reatores UASB foram de 40, 30, 20 e 11 h nos sistemas I e II. As eficiências médias de remoção de coliformes totais e termotolerantes no sistema I foram de 92,92 a 99,50% e de 94,29 a 99,56% respectivamente, e no sistema II aumentaram para 99,45 a 99,91% e 99,52 a 99,93%, respectivamente. As remoções médias de ovos de helmintos no sistema I foram de 96,44 a 99,11% e no sistema II alcançaram 100% em todos os ensaios. No lodo dos reatores, a contagem de coliformes totais e termotolerantes variou de 105 a 109 NMP (100 mL)-1 e de ovos de helmintos de 0,86 a 9,27 ovos g-1 ST. Não foram detectados cistos de protozoários nos afluentes, efluentes e lodos / Abstract: The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two up-flow anaerobic sludge blanket (UASB) reactors, with volumes of 510 and 209 L, placed in series; system II consisted of a UASB reactor, anaerobic filter, trickling filter and decanter, placed in series, with volumes of 300, 190, 250 and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20 and 11 h in systems I and II. The mean removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, and reached 100% in all assays in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 105 and 109 MPN (100 mL)-1, while helminth eggs ranged from 0,86 a 9,27 eggs g-1 TS. Not protozoan cysts were detected in the tributaries, effluents and sludge / Mestre
255

Tratamento de águas residuárias de suinocultura em reatores anaeróbios seguidos de filtro biológico percolador e wetlands /

Silva, Gilvânia Campos. January 2013 (has links)
Orientador: Roberto Alves de Oliveira / Banca: Luciano Santos Rodrigues / Banca: Valéria Del Nery / Banca: Valderi Duarte Leite / Banca: Eloisa Pozzi / Resumo: As águas residuárias de suinocultura apresentam altas concentrações de matéria orgânica, nutrientes e patógenos. Esse resíduo é passível de ser tratado por via anaeróbia, com vantagens como a produção de biogás e o efluente final com poder poluente reduzido. Foram avaliados dois sistemas de tratamento anaeróbio de águas residuárias de suinocultura, o primeiro, constituído por dois reatores UASB em dois estágios seguidos de wetlands e o outro sistema de tratamento, composto por reator UASB, filtro anaeróbio, filtro biológico percolador, decantador e wetlands, instalados em série na remoção de matéria orgânica, e nutrientes e na produção de metano sob tempos de detenção hidráulico (TDH) de 11 a 40 h e cargas orgânicas volumétricas (COV) de 4,3 a 18,7 g DQO total (L d)-1. No sistema de tratamento anaeróbio I, constituído por dois reatores UASB em série, os valores máximos de remoção de demanda química de oxigênio total (DQO total), sólidos suspensos voláteis (SSV), fósforo total (P-total), nitrogênio Kjeldhal (NK), cobre (Cu), zinco (Zn) e coliformes termotolerantes foram 89, 92, 70, 58, 80, 95 e 99,56 % respectivamente. No sistema II, com reator UASB e filtro anaeróbio, em série, as médias máximas de remoção de DQO total, SSV, P-total, NTK, Cu, Zn e coliformes termotolerantes foram 87; 87; 64; 55, 80; 95 e 99,90 % respectivamente. Os valores máximos da produção volumétrica de metano foram de 0,419 e 0,488 L CH4 (L reator d)-1 nos sistemas I e II, respectivamente. Em relação ao pós-tratamento com filtro biológico percolador e decantador os valores de DQO total, SSV, P-total, NTK, Cu, Zn e coliformes termotolerantes aumentaram para 92; 87; 86; 62, 87; 97 e 99,93 %, respectivamente. Com wetlands as eficiências de remoção aumentaram para 98; 98, 98; 94; 88; 98 e 99,99 %, respectivamente, para DQO total, SSV, P-total, NK, Cu, Zn e coliformes ter ... / Abstract: The swine wastewater have high concentrations of organic matter, nutrients and pathogens. This residue is likely to be treated anaerobically, with advantages such as biogas production and the final effluent with low polluting power. Two systems of anaerobic treatment of swine wastewater, the first, consisting of two-stage UASB followed by wetlands and other treatment system consisting of UASB reactor, anaerobic filter, trickling filter, decanter and wetlands, were evaluated at in series in the removal of organic matter and nutrients and the production of methane in hydraulic retention time (HRT) from 11 to 40 h and volumetric organic load (VOL) from 4.3 to 18.7 g total COD (L d )-1. In anaerobic treatment system I, consisting of two UASB reactors in series, the maximum values of removing total chemistry oxygen demand (total COD), volatile suspended solids (VSS), total phosphorous (total P), Kjeldahl nitrogen (NK), copper (Cu), zinc (Zn) and thermotolerants coliforms were 89, 92, 70, 58, 80, 95, and 99.56 %, respectively. In system II, with UASB and anaerobic filter in series, the maximum average total COD removal, SSV, total-P, KN, Cu, Zn and thermotolerants coliforms were 87, 87, 64, 55, 80, 95 and 99,90 % respectively. The maximum values of the volumetric methane production were 0.419 and 0.488 L CH4 (L reactor d) -1 in systems I and II, respectively. In relation to post- treatment with biological trickling filter and decanter values of total COD, VSS, total-P, KN, Cu, Zn and thermotolerants coliforms increased to 92, 87, 86, 62, 87, 97 and 99.93 %, respectively. With the wetlands, the removal efficiencies increased to 98, 98, 98, 94, 88, 98 and 99,99 %, respectively, for total COD, VSS, total-P, NK, Cu, Zn and thermotolerants coliform . The anaerobic reactors were effective to remove organic matter and contribute to the removal of nutrients, although the system I has advantages of ... / Doutor
256

Comparação entre as diferentes formas de avaliar a taxa da Filtração Glomerular na população idosa atendida no Centro de Atenção Integrada de Melhor Idade - CAIMI na cidade de Manaus /

Almeida, Gilsirene Scantelbury de. January 2013 (has links)
Orientador: Roberto Jorge da S. Franco / Coorientador: Luis Cuadrado Martin / Banca: Pasqual Barretti / Banca: Vanessa dos Santos Silva / Banca: Eduardo Barbosa Coelho / Banca: Marcio Dantas / Resumo: A doença renal crônica (DRC) representa um problema de saúde pública global. Os idosos têm diminuição progressiva da função renal e os hipertensos e diabéticos apresentam maior risco de lesão renal. Essas doenças crônicas são comuns aos idosos favorecendo o comprometimento de lesão renal. Com base neste fato, o objetivo do estudo foi identificar o melhor método para avaliar precocemente a filtração glomerular (FG) em indivíduos idosos. Comparando-se as fórmulas baseadas na creatinina sérica, bem como o Clearance de Creatinina de 24h com a fórmula baseada nos níveis séricos de Cistatina C, eleita como padrão ouro. Foi realizado um estudo observacional, analítico, de delineamento transversal sobre a filtração glomerular e o desenvolvimento da doença renal, com base nos resultados obtidos na avaliação clínica e nos exames laboratoriais de bioquímica e urinálise. Participaram do estudo 180 idosos de ambos os sexos, com idade igual ou superior a 60 anos, do Centro de Atenção Integrada da Melhor Idade (CAIMI), da cidade de Manaus-AM. Foram construídos gráficos de dispersão, calculado o coeficiente de correlação, bem como traçados diagramas de Bland Altman e curvas ROC. A média de idade dos 180 idosos foi de 67 anos - 68,8% do sexo feminino, e 31,1% do sexo masculino. Hipertensos representaram 43,5% do total. Renais crônicos representaram 19%. Portadores de diabetes mellitus chegaram a 38,3%. Ao observar a equação de regressão, quando o CKD-epiCys for zero, o Clearance de Creatinina (ClCr) valerá 62,07 ml/min/1,73m2, o que caracteriza uma superestimação do valor real da FG. A média avaliada pelo ClCr e CKD-epiCys foi de 28,8 ml/min/1,73m2. Este valor é bem superior à zero, que seria o ideal. Isto mostra que o ClCr superestima a FG avaliada pelo CKD-epiCys. A curva ROC para o ClCr na discriminação da presença de FG< 60 ml/min avaliada pelo padrão foi de 0,65, com ... / Abstract: Chronic kidney disease (CKD) is a global public health problem. The elderly have progressive decrease of renal function, and those with hypertension and diabetes are at increased risk of kidney damage. These chronic diseases are common to the elderly and promote renal injury. This study aimed to identify the best method to assess early glomerular filtration (GF) in elderly subjects. Formulas based on serum creatinine and creatinine clearance of 24 hours were compared with the formula based on serum cystatin C chosen as gold standard. We conducted an observational, analytical, cross-sectional design of the glomerular filtration rate and the development of kidney disease, through results obtained in clinical evaluation, and biochemistry and urinalysis laboratory tests. Participants were 180 patients of both sexes, aged over 60 years, from the Centro de Atenção Integrada da Melhor Idade [Center for Integrated Management of the Elderly], in the city of Manaus, State of Amazonas, Brazil. Scatter plots were constructed by calculating the correlation coefficient, as well as Bland Altman plotted diagrams and ROC curves. The average age of the elderly participants was 67 years; 68.8% were female and 31.1% male; 43.5% had hypertension; 19%, chronic renal failure; and 38.83%, diabetes mellitus. By observing the regression equation, when the CKD-epiCys was zero, creatinine clearance (CrCl) was 62.07 ml/min/1.73m2, which means overestimation of the real FG rate. The average assessed by CrCl. and CKD-epiCys was 28.8 ml/min/1,73m2, a value above zero, which would be ideal. This shows that CrCl. overestimates FR assessed by CKD-epiCys. The ROC curve for CrCl to discriminate the presence of FG <60 ml / min measured by the standard was 0.65, with 95% confidence interval from 0.56 to 0.76 (p = 0.006). The CrCl had statistically significant predictive power concerning the presence of KD. The regression was assessed by ... / Doutor
257

Remoção de células e subprodutos de Microcystis spp. por dupla filtração, oxidação e adsorção / Removal of cells and by-products of Microcystis spp. in double filtration, oxidation and adsorption processes

Kuroda, Emília Kiyomi 18 December 2006 (has links)
Considerando o aumento da ocorrência de florações de cianobactérias e a possibilidade de formação de subprodutos em diversos mananciais destinados ao consumo humano, este trabalho teve como objetivo, avaliar a remoção de células e subprodutos de Microcystis spp. pelos processos de dupla filtração com filtração ascendente em pedregulho e de filtração descendente em areia, oxidação e adsorção com carvões ativados pulverizado e granular. Na fase 1 foram realizados ensaios de bancada para estabelecimento das condições operacionais dos ensaios a serem realizados em instalação piloto, utilizando-se água de estudo preparada com adição de cultura de cepa tóxica de Microcystis spp. e ou extrato de microcistinas. Em seguida, foram realizados ensaios em instalação piloto de escoamento contínuo para águas de estudo preparadas com adição de cultura de cepa tóxica de Microcystis spp. e de extrato de microcistinas – fase 2 e de material coletado no reservatório de Barra Bonita – SP - fase 3. A concepção de dupla filtração utilizada mostrou ser bastante eficiente na remoção de células de Microcystis spp. e, consequentemente, de microcistinas intracelulares, porém, a remoção ou degradação de microcistinas extracelulares só foi significativa com o emprego de processos complementares de oxidação e ou adsorção. Para as águas de estudo empregadas, não houve formação expressiva de subprodutos organohalogenados nos efluentes dos processos de tratamento, após serem submetidas à cloração e tempo de contato de 1 dia. Adicionalmente, foram realizados estudos prospectivos no sentido de avaliar a toxicidade de extrato, águas de estudo e efluentes dos processos de tratamento por meio de bioensaios com cladóceros e camundongos, além de biomonitoramento com a espécie de peixe Danio rerio. / Considering the increase in the frequency of cyanobacterial blooms and the possibility of by-product formation in water supply sources for human consumption, this work was carried out in order to evaluate the removal of cells and by-products of Microcystis spp. using the processes of double filtration (gravel upflow filtration of coagulated water followed by rapid sand downflow filtration), oxidation and adsorption in powdered and granular activated carbons. Bench scale assays were performed in phase 1 to determine the operational conditions of the tests to be performed in a continuous flow pilot plant, using a study water prepared with filtered water in the water treatment plant 2 of Sao Carlos and culture of a toxic strain of Microcystis spp. and/or microcystins extract. Based on the conditions stated in phase 1, phase 2 was carried out by performing tests in the pilot plant for study waters prepared with culture of toxic strain of Microcystis spp. and phase 3 of microcystins extract from material collect in the de Barra Bonita – SP reservoir. The double filtration system used resulted very efficient concerning the removal of cells of Microcystis spp., but, on the other hand, the removal or degradation of extracellular microcystins was significant with the use of complementary processes such as oxidation and or activated carbon adsorption. With regards to the waters studied, there wasn’t significant formation of by-products due to the oxidation of the effluent of each combination of processes, when submitted to chlorination with detention time of 1 day. Additionally, it was observed the toxicity effect by bioassays with crustaceans and mices, besides Danio rerio fish screening.
258

Sistema de filtração lenta no tratamento de percolado do aterro sanitario de Limeira-SP / Slow sand filter in the treatment of leachate of the sanitary landfill of Limeira -SP

Pelegrini, Nubia Natalia de Brito 17 February 2006 (has links)
Orientador: Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-06T12:32:37Z (GMT). No. of bitstreams: 1 Pelegrini_NubiaNataliadeBrito_M.pdf: 1010430 bytes, checksum: 1a5af5bc021dbf527427add6944a6e6d (MD5) Previous issue date: 2006 / Resumo: A disposição final de resíduos sólidos é uma prática que ainda traz sérios impactos ao meio ambiente. Nos aterros sanitários, os resíduos passam por processos físicos, químicos e biológicos de decomposição, gerando uma fração gasosa (composta principalmente por gases dióxido de carbono e metano) e uma fase líquida conhecida como chorume (ou percolado de aterro sanitário). O chorume de lixo é um líquido com elevado potencial poluente, os métodos convencionais utilizados em seu tratamento têm descartado-o com intensa coloração e alta toxicidade. Este trabalho teve como objetivo implantar em escala piloto um sistema de filtração lenta precedido de uma pré-filtração, apenas em manta sintética não tecida, para o tratamento de chorume de lixo ¿in natura¿, proveniente do aterro sanitário da cidade de Limeira-SP. O filtro lento foi constituído por um tanque cilíndrico de plástico tendo como meio filtrante areia e mantas sintéticas não tecidas. A taxa de filtração adotada durante os experimentos foi de 3 m3/m2.dia. O sistema de tratamento em estudo apresentou reduções consideráveis dos valores de alguns parâmetros de controle ambiental indicando a possibilidade do uso da filtração lenta para remediação de águas residuárias. As principais reduções obtidas referem-se a 40% de turbidez, 21% da coloração, 35% de dureza, 35% de carbono orgânico total (TOC) e reduções consideráveis de metais pesados (60% de cádmio, 30% de chumbo, 25% de cobre e 30% de cromo). Com relação à reutilização do chorume tratado em atividades agrícolas ainda são necessárias maiores reduções dos valores de parâmetros analíticos através da complementação com outras tecnologias de tratamento / Abstract: The final disposition of solids residues is a practice that still brings serious impacts to the environment. In sanitary landfill, the residues goes through physical, chemical and biological decomposition processes, generating into a gas phase (mainly composed by CH4 and CO2) and a liquid phase known as leachate. The waste leachate is a liquid with high pollutant potential. The conventional methods used in the treatment this residue have discarded him with intense coloration and high toxicity. This work had as objective implant in pilot scale a system of slow sand filtration preceded of a pré-filtration, only in non-woven synthetic fabrics, for the waste leachate treatment in natura, originating from the sanitary landfill of the city of Limeira-SP. The slow sand filter is constituted by a plastic cylindrical tank, sands and non-woven synthetic fabrics. The filtration rate adopted during the experiments it was of 3 m3/m2.dia. The treatment system in study presented considerable reductions of some values of environmental parameters control indicating the possibility of the use of the slow filtration for remediação of wastewaters. The main obtained reductions were 40% of turbidity, 21% of color, 35% of hardness, 35% of total organic carbon (TOC) and reductions considerably of heavy metals (60% of cadmium, 30% of lead, 25% of cupper and 30% of chrome). For the reuse of the treated leachate in agricultural activities are necessary larger reductions of some values of analytic parameters through the complementation with other treatment technologies. eywords: Landfill Leachate, Sanitary Landfill, Slow Sand Filtration, Reuse / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
259

Remoção de células e subprodutos de Microcystis spp. por dupla filtração, oxidação e adsorção / Removal of cells and by-products of Microcystis spp. in double filtration, oxidation and adsorption processes

Emília Kiyomi Kuroda 18 December 2006 (has links)
Considerando o aumento da ocorrência de florações de cianobactérias e a possibilidade de formação de subprodutos em diversos mananciais destinados ao consumo humano, este trabalho teve como objetivo, avaliar a remoção de células e subprodutos de Microcystis spp. pelos processos de dupla filtração com filtração ascendente em pedregulho e de filtração descendente em areia, oxidação e adsorção com carvões ativados pulverizado e granular. Na fase 1 foram realizados ensaios de bancada para estabelecimento das condições operacionais dos ensaios a serem realizados em instalação piloto, utilizando-se água de estudo preparada com adição de cultura de cepa tóxica de Microcystis spp. e ou extrato de microcistinas. Em seguida, foram realizados ensaios em instalação piloto de escoamento contínuo para águas de estudo preparadas com adição de cultura de cepa tóxica de Microcystis spp. e de extrato de microcistinas – fase 2 e de material coletado no reservatório de Barra Bonita – SP - fase 3. A concepção de dupla filtração utilizada mostrou ser bastante eficiente na remoção de células de Microcystis spp. e, consequentemente, de microcistinas intracelulares, porém, a remoção ou degradação de microcistinas extracelulares só foi significativa com o emprego de processos complementares de oxidação e ou adsorção. Para as águas de estudo empregadas, não houve formação expressiva de subprodutos organohalogenados nos efluentes dos processos de tratamento, após serem submetidas à cloração e tempo de contato de 1 dia. Adicionalmente, foram realizados estudos prospectivos no sentido de avaliar a toxicidade de extrato, águas de estudo e efluentes dos processos de tratamento por meio de bioensaios com cladóceros e camundongos, além de biomonitoramento com a espécie de peixe Danio rerio. / Considering the increase in the frequency of cyanobacterial blooms and the possibility of by-product formation in water supply sources for human consumption, this work was carried out in order to evaluate the removal of cells and by-products of Microcystis spp. using the processes of double filtration (gravel upflow filtration of coagulated water followed by rapid sand downflow filtration), oxidation and adsorption in powdered and granular activated carbons. Bench scale assays were performed in phase 1 to determine the operational conditions of the tests to be performed in a continuous flow pilot plant, using a study water prepared with filtered water in the water treatment plant 2 of Sao Carlos and culture of a toxic strain of Microcystis spp. and/or microcystins extract. Based on the conditions stated in phase 1, phase 2 was carried out by performing tests in the pilot plant for study waters prepared with culture of toxic strain of Microcystis spp. and phase 3 of microcystins extract from material collect in the de Barra Bonita – SP reservoir. The double filtration system used resulted very efficient concerning the removal of cells of Microcystis spp., but, on the other hand, the removal or degradation of extracellular microcystins was significant with the use of complementary processes such as oxidation and or activated carbon adsorption. With regards to the waters studied, there wasn’t significant formation of by-products due to the oxidation of the effluent of each combination of processes, when submitted to chlorination with detention time of 1 day. Additionally, it was observed the toxicity effect by bioassays with crustaceans and mices, besides Danio rerio fish screening.
260

Rosiglitazone pode causar lesão tubular renal em ratos normais mas não em ratos hipercolesterolêmicos / Rosiglitazone may induce renal injury in normal rats but not in hypercholesterolemic rats

Dias, Cristiano 27 October 2009 (has links)
Introdução: Rosiglitazone (RGL) é um ligante dos receptores PPAR e vem sendo usada no tratamento do Diabetes Mellitus tipo 2 e nas doenças inflamatórias. Mas, RGL pode reduzir a filtração glomerular (FG), a carga excretada de sódio na urina (UVNa) e aumentar a expressão da Na+,K+- ATPase na medula renal. Então, RGL pode causar edema e insuficiência cardíaca congestiva. Entretanto, não tem sido reportado se RGL pode induzir insuficiência renal aguda (IRA). Objetivo: Verificar se a redução da FG causada pelo tratamento com RGL predispõe à IRA em ratos. Avaliar em condições basais e de vasoconstrição renal e se há diferenças entre ratos normocolesterolêmicos (NC) e hipercolesterolêmicos (HC). Métodos: A FG foi medida pelo clearance de inulina no 8º dia em ratos (~200g) NC e HC tratados ou não com RGL (48 mg/kg/dieta) na situação basal e durante a infusão endovenosa de Ang II (40 ng/kg/min). Além disso, a atividade da Na+,K+-ATPase foi avaliada em homogenato renal em outra série de animais. Resultados: Na situação basal, NC e HC apresentaram FG semelhante e o tratamento com RGL reduziu a FG apenas em NC de 0,78±0,03 para 0,50±0,05* ml/min/100g, *p<0,001. Apesar da redução da FG, a UVNa em NC+RGL não se modificou. Durante a infusão de Ang II, a FG de NC, HC e HC+RGL reduziu-se para o mesmo patamar de NC+RGL e um significante aumento da UVNa foi observada apenas em NC+RGL (NC= 3,32±0,88; NC+RGL=5,86±1,04*; HC= 2,63±0,43 e HC+RGL= 2,23±0,39 uEq/min, *p<0,01). Além disso, RGL induziu aumento na atividade da Na+,K+-ATPase em HC+RGL e não modificou em NC+RGL. Os valores expressos em M Pi/mg proteína.h-1 foram de 45±7 em NC, 43±5 em NC+RGL, 48±7 em HC e 64±4* em HC+RGL, *p<0,05. Analisando todos os resultados em conjunto, a redução da FG associada com a alta natriurese e ausência da modulação da atividade da Na+,K+-ATPase em NC+RGL sugerem lesão renal neste grupo. Conclusão: Os mecanismos de ação da RGL diferem de acordo com a condição metabólica. Então, RGL deve ser prescrita com cautela na ausência de hipercolesterolemia e requer a monitoração da função renal principalmente nas situações de vasoconstrição / Introduction: Rosiglitazone (RGL) is a ligand for PPAR used to treat type 2 Diabetes Mellitus and inflammatory diseases. However, RGL can reduce the glomerular filtration rate (GFR), urinary sodium excretion (UVNa) and increase the expression of Na+, K+-ATPase in renal medulla. Thus, RGL may induce edema and congestive heart failure. However, acute renal failure (ARF) provoked by RGL treatment has not been reported. Aim: To test whether reduced GFR by RGL may predispose to ARF at baseline and during a renal vasoconstriction state, and if the findings differ between normocholesterolemic (NC) and hypercholesterolemic (HC) rats. Methods: GFR was measured by inulin clearance on the 8th day in NC and HC rats (~200g) treated or not with RGL (48 mg/kg diet) at baseline and during intravenous infusion of Ang II (40 ng/kg/min). Furthermore, the Na+,K+- ATPase activity was determined in renal homogenates in other series of animals. Results: At baseline, NC and HC had similar GFR and the treatment with RGL reduced GFR only in NC from 0.78±0.03 to 0.50±0.05* ml/min/100g, *p<0.001. Although GFR was reduced, UVNa was unchanged in NC+RGL. During Ang II infusion, GFR was significantly reduced in NC, HC and HC+RGL and it remained at the same reduced level in NC+RGL. At this time, when GFR was reduced the same range in all groups, a significant increment in UVNa was only observed in NC+RGL (NC = 3.32±0.88; NC+RGL = 5.86±1.04*; HC = 2.63±0.43 and HC+RGL = 2.23±0.39 Eq/min, *p<0.01). Moreover, RGL induced an increase in the activity of Na+, K+-ATPase in HC+RGL, but it did not modify the activity of this enzyme in NC+RGL. The values expressed in M Pi/mg.protein.h-1 were 45±7 in NC, 43±5 in NC+RGL, 48±7 in HC and 64±4* in HC+RGL, *p<0.05. Taken together, reduction in GFR associated with high natriuresis and without changes in the Na+, K+-ATPase activity in renal medulla of NC+RGL may suggest renal injury in this group. Conclusion: RGL may act distinctly in normocholesterolemia and in hypercholesterolemia. Thus, RGL may be prescribed with caution in absence of hypercholesterolemia and requires monitoring of renal function specially if a renal vasoconstriction state is associated.

Page generated in 0.078 seconds