• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 541
  • 253
  • 123
  • 86
  • 48
  • 39
  • 19
  • 16
  • 12
  • 10
  • 8
  • 6
  • 6
  • 6
  • 6
  • Tagged with
  • 1373
  • 281
  • 211
  • 200
  • 177
  • 175
  • 157
  • 148
  • 130
  • 120
  • 116
  • 81
  • 79
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Analyse multi-échelle de la filtration sur microsive de particules modèles inertes et biologiques : caractérisation in situ du dépôt par microscopie confocale / In situ multiscale 3D characterization of model inert and biological particle cakes using confocal laser scanning microscopy

Ben Hassan, Ines 15 April 2014 (has links)
Durant les opérations de filtration membranaire, les industries font face à un problème majeur : le colmatage. En particulier, la formation d’un dépôt de particules sur la membrane provoque une chute de sa perméabilité et de sa sélectivité. L’étude a pour but de mieux caractériser la morphologie des dépôts de particules, en lien avec ses propriétés de transport, dans le but d’enrichir les modèles utilisés pour prédire les performances de filtration des dispositifs industriels. Des expériences de filtration de suspensions pures et mixtes de particules inertes et biologiques, sont réalisées sur des microsieves et observées in situ par microscopie confocale. Les propriétés spatiales du dépôt (arrangement des particules, épaisseur, porosité, taux de couverture de la membrane) sont déterminées par traitement d’images et corrélées aux variations de perméabilité. L’influence des paramètres tels que : la taille des particules, la géométrie de la microsieve (taille de pore, distance entre pores) et la nature des particules, est soigneusement analysée. Plusieurs mécanismes physiques sont mis en évidence : - La préfiltration de grosses particules avant la filtration des petites maintient un débit élevé.- Les particules déposées protègent les pores qui leurs sont périphériques lorsque le rapport « taille de particules / taille de pores » est élevé.-Dans les conditions expérimentales étudiées, la morphologie des dépôts de particules inertes et biologiques est identique.- Le dépôt est structuré en trois régions distinctes : une zone de germination en contact avec la membrane, une couche centrale dense, une région de capture superficielle / During the operations of filtration, the industries are facing a major problem: fouling. Indeed, the cake layer build-up on top of the membrane reduces its productivity and selectivity. The aim of this study is to characterize the particle deposit morphology at different operating conditions in order to enhance the models used to predict the filtration performances at the industrial level. Pure and mixed suspensions of inert and biological particles are filtrated with microsieves and observed in situ by Confocal Laser Scanning Microscopy (CLSM). The spatial properties of the cake (particle arrangement, thickness, porosity, microsieve coverage) are determined by image processing and correlated with the permeability reduction. The effect of the parameters such as: the particles size, the microsieve geometry (pore size, pore pitch) and the particles characteristics, is carefully analyzed. Several physical mechanisms are highlighted:- The prefiltration of large particles before the filtration of the small ones maintains a high flux.- Deposited particles protect the surrounding pores when the ratio "particles size/pores size" is high.- In the studied experimental conditions, the cake morphology of the inert and biological particles is similar.- The cake is structured in three regions: germination region in contact with the membrane, a central high particle concentration region and a superficial region, named capture region
272

Impact sur le colmatage en régimes transitoire et permanent des écoulements d’air induits par le plissage des médias filtrants THE / Impact of the air flows induced by the pleating of HEPA filters during clogging in stationary and transient state

Alilou, Youssef 02 March 2018 (has links)
Les filtres plissés à très haute efficacité (THE) jouent un rôle essentiel dans le maintien du confinement des installations industrielles à risques, les réacteurs nucléaires par exemple. Ces filtres permettent le piégeage des aérosols, qui sont la principale source de contamination externe. Dans ce cadre, l’IRSN (Institut de Radioprotection et de Sûreté Nucléaire) conduit des études pour caractériser les performances des filtres THE. L’objectif de la présente thèse a été de développer un modèle prédictif décrivant l’évolution de la résistance aéraulique du filtre au cours de son colmatage. Le colmatage d’un filtre plissé THE est piloté, d’une part par les conditions aérauliques imposées dans les réseaux de ventilation, d’autre part par la nature du média et les propriétés des particules collectées par le filtre. Ainsi, les travaux réalisés ont été répartis sur deux volets. La première partie a été dédiée à l’étude de l’aéraulique du filtre suivant une approche double expérimentale et numérique. Un banc expérimental permettant de mesurer les champs de vitesse dans un pli de filtre plissé THE a été développé. Les mesures réalisées ont servi à la validation des codes de calcul utilisés (ANSYS CFX® et GeoDict®) et au développement d’un modèle de perte de charge initiale des filtres plissés vierges. Une validation du modèle à l’échelle de filtres complets avec des géométries différentes a ensuite été effectuée. La deuxième partie a porté sur l’étude du colmatage des filtres plissés THE suivant une approche expérimentale et numérique. Un banc expérimental a été développé pour la détermination des paramètres entrant en jeu dans les modèles de colmatage (porosité, taille de particules …), puis des simulations numériques à l’aide du logiciel GeoDict ont été réalisées pour caractériser la croissance du dépôt sur la média. La combinaison des résultats expérimentaux et numériques a conduit au développement d’un modèle décrivant l’évolution de la résistance aéraulique du filtre THE au cours de son colmatage avec des particules microniques / High Efficiency Particulate Air (HEPA) pleated filters are used to ensure the containment of airborne contamination within nuclear facilities. These filters are often the last barrier before a potential release of radioactive substances into the environment. Predicting their performances (pressure drop and efficiency) is a main thrust of research for IRSN which aims at avoiding any unexpected failure of those devices on French nuclear facilities. The clogging phenomenon is mainly influenced, on one side, by the flow conditions imposed in the ventilation network and, on the other side, by the media characteristics and the particles properties which are collected by the filter. Consequently, the work carried out has been divided into two parts. In the first part, we focused on the study of the airflow behavior within a HEPA pleated filter with an experimental and numerical approach. An experimental bench has been developed to measure the airflow field at the entrance channel of a HEPA filter pleat. Then, the experimental measurements have been used to validate GeoDict® and ANSYS CFX® simulations. The combination of the experimental and the numerical results have been used to develop a model to predict the evolution of the initial HEPA filter pressure drop. The work performed in the second part deals with the clogging of the filter. An experimental bench, dedicated to the characterization of the parameters that intervene in the clogging models such as the porosity, the pressure drop and the particles size, has been developed. Then, numerical simulations conducted with GeoDict® have been realized to describe the cake formation on the surface of a HEPA pleated filter. Finally, we developed a model to predict the evolution of HEPA pressure drop during clogging with micronic particles
273

Forward osmosis membranes for direct fertigation within the South African wine industry

Augustine, Robyn January 2017 (has links)
Thesis (MTech (Chemical Engineering))--Cape Peninsula University of Technology, 2017. / Water scarcity in South Africa (SA) and more specifically Cape Town, Western Cape, has escalated to disaster levels in 2018. Agriculture and irrigation account for 62% of SA’s accessible potable water (Thopil & Pouris, 2016), and although the agriculture sector plays a pivotal role in SA’s socio-economic development, the future of the sector is dependent on critical issues such as climate variability and population growth (Besada & Werner, 2015). Wine production in SA is an important agricultural activity, contributing great economic value to the agri-food sector. However, despite this, the wine industry is responsible for vast water consumption and the unsafe disposal of winery wastewater, which are critical issues from an environmental and economic standpoint. The ever-imminent crisis pertaining to the limited supply of fresh water from conventional water resources has necessitated the need to develop alternative water resources to supplement an increased water supply, which include the reuse of wastewater, ground water, brackish water (BW) and seawater (SW) desalination. When fresh water supplies are limited, agricultural irrigation is penalised. The reuse of agricultural wastewater as a substitution for potable water irrigation may prove beneficial in areas where water shortages are severe. Forward osmosis (FO) is a developing desalination technology that has received increased attention as a promising lower-energy desalination technology. FO technology relies on the natural osmotic process, driven by a concentration gradient as opposed to significant hydraulic pressures like reverse osmosis (RO). Water is extracted from a lower concentrated feed solution (FS) to a highly concentrated draw solution (DS). The term “lower energy” is only applicable for applications where the recovery of the DS is not required. FO technology offers several advantages. However, the lack of suitable membrane modules and DSs hinder its practical application. FO offers novelty applications in which specialised DSs are selected to serve as the final product water, most notably concentrated fertilisers for direct fertigation. The aim of this study was to evaluate the performance and compatibility of commercially available cellulose triacetate (CTA) and aquaporin biomimetic FO membranes with commonly used fertilisers for direct fertigation within the SA wine industry, using a fertiliser drawn forward osmosis (FDFO) system.
274

Concentração dos compostos bioativos da polpa de caju através da tecnologia de separação por membranas / Concentration of bioactive compounds from cashew pulp through the membrane separation technology

Aragão, Vitor Cardoso 16 August 2018 (has links)
Orientador: Luiz Antonio Viotto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-16T15:09:54Z (GMT). No. of bitstreams: 1 Aragao_VitorCardoso_M.pdf: 24667978 bytes, checksum: b244b99f0ba81a272f7b8a6fc720e5d1 (MD5) Previous issue date: 2010 / Mestrado / Mestre em Engenharia de Alimentos
275

Étude de nouveaux media granulaires et non tissés pour la filtration du vin / Study of new granular and nonwoven filter media for wine filtration

Blackford, Marie 01 December 2017 (has links)
Les membranes et les adjuvants de filtration sont très utilisés pour la filtration des vins. Les adjuvants de filtration forment un dépôt filtrant assurant l’efficacité du filtre. Cependant ces particules ne sont pas régénérables. L’objectif de ces travaux est de proposer un media filtrant régénérable et disponible en plusieurs granulométries, afin d’être utilisé lors des différentes étapes de l’élaboration des vins. Les Rilsan® en polyamide 11 biosourcé sont étudiés et caractérisés en tant qu’alternative aux diatomites. Les résultats montrent qu’avec la gamme de Rilsan® existante il est possible d’obtenir les différents grades nécessaires pour la filtration du vin. Les distributions de tailles de particules, la formation des dépôts ainsi que les efficacités de filtration ont été déterminées. Lors de la filtration sur précouche de Rilsan® les mécanismes de rétention suivent une loi de colmatage intermédiaire des pores. Du fait de la structure non poreuse du matériau par rapport aux diatomites, leur régénération est possible et a été étudiée par hydrocyclonage. Les non-tissés ont l’avantage d’avoir de très fortes porosités ; ce qui est un atout pour obtenir des débits de filtration importants. De nouveaux media en polyamide 11 fabriqués par Electrospinning sont testés comme une alternative aux membranes actuelles, de plus faible porosité. Les diamètres de pores obtenus de l’ordre de 1,5 μm sont encore trop élevés pour envisager une stabilisation microbiologique du vin. La faible résistance mécanique des media est un frein à leur développement pour la filtration des liquides. Les perméabilités sont peu dépendantes de la dimension des pores dans la gamme testée et dépendent principalement de l’épaisseur du matériau et d’autres paramètres de fabrication. / Membranes and filter aids are classically used filter media throughout the wine making process. During filtration, filter aids form a precoat inducing the retention efficiency of the filter. However, these particles are not regenerable. The aim of this study is to find a cleanable and reusable alternative to existing filter aids, available in various grain-size distributions, in order to perform the different types of wine filtration. The Rilsan® powder, made of biobased polyamide 11, are characterized and studied as an alternative to diatomaceous earth mainly used for enology applications. Results showed that the range of Rilsan® allowed performing both rough and clarifying filtration. The particle size distribution, the granular bed deposition and the filtration efficiency were determined. During filtration using Rilsan® precoat, the fouling mechanisms follow an intermediate pore blocking law. According to their non-porous structure compared to diatomite, these particles are cleanable. Hydrocyclone process is studied in order to achieve this regeneration. Nonwovens have important porosities which is an asset to have high filtration flow rates. New filter media made by electrospinning process of polyamide 11 are tested as an alternative to currently used filtration membranes. The pore diameters measured of 1.5 μm are still too large to be used for wine microbiological stabilization. Their mechanical weakness is a brake to their use in liquid filtration applications. Water permeability is little influenced by the pore size, in the range of media tested, and depends mainly on the thickness of the media and other fabrication processes.
276

Approches micro/milli-fluidiques pour l'étude in situ de procédés de filtration frontale / Micro/milli-fluidic approaches for the in situ study of frontal filtration processes

Decock, Jérémy 28 November 2017 (has links)
Ce travail de thèse porte sur le développement technologique d’outils miniaturisés micro- (10 µm) et milli- (1 mm) fluidique, pour l’étude in situ de procédés de filtration frontale, en collaboration avec l’entreprise Solvay. Les outils développés permettent le suivi visuel de la formation de gâteaux de filtration en opérant des essais à pression ou à débit constant sur diverses suspensions colloïdales, jusqu’à des pressions trans-membranaires de l’ordre de 7 bars.L’étude millifluidique de la filtration de dispersions industrielles de silice colloïdale (Solvay, Silica), a permis de mettre en évidence la croissance de gâteaux compressibles et de corréler ces données aux signaux de pression, obtenus à débit imposé. Ces mêmes données sont confrontées aux lois classiques de la filtration (« cake filtration theory »), mettant en évidence que les modélisations classiques ne peuvent pas reproduire les comportements observés.La seconde partie de la thèse porte sur le développement d’un outil microfluidique, intégrant des membranes hydrogel nano-poreuses, pouvant résister à de fortes pressions (quelques bars). Ces membranes sont fabriquées in-situ par photo-polymérisation de formulations aqueuses contenant des PEG-diacrylates et des agents porogènes. Notre travail a permis une caractérisation précise de leur perméabilité en fonction de divers paramètres (formulation, temps d’exposition, géométrie). Ces mêmes membranes ont été utilisées pour suivre la filtration frontale de nanoparticules aux échelles microfluidiques, et ainsi estimer quantitativement la perméabilité des gâteaux formés. / This work deals with the technological development of miniaturized micro- (10 µm) and milli- (1 mm) fluidic tools for in-situ investigations of frontal filtration processes, in collaboration with Solvay. The tools that we developed, make it possible to monitor visually the formation of the filter cake, operating at constant-pressure or constant-flow rate filtration, on various colloidal suspensions, and up to trans-membrane pressures of 7 bars.We performed a millifluidic study of the filtration of industrial silica colloidal dispersions (Solvay, Silica), and we evidenced the growth of compressible cakes. We correlated these data to the pressure signals obtained at imposed flow rates. The comparison with theoretical predictions given by the classical laws of cake filtration theory, shows that such conventional models cannot reproduce the observed behaviors.The second part of this thesis reports the development of high pressure-resistive (several bars) microfluidic tools integrating nano-porous hydrogel-based membranes. These membranes are fabricated in situ by photo-polymerization of aqueous formulations containing PEG-diacrylates and porogen agents. We reported precise characterizations of their permeability in function of several parameters (formulation, exposure time, geometry). The same membranes were used to monitor frontal filtration of nanoparticles at the microfluidic scale, and thus to quantitatively estimate the permeability of the formed cakes.
277

The design of electrostatically augmented moving bed granular gas filters

Kornelius, Gerrit 05 May 2005 (has links)
Granular gas bed filters have been used in industry for a considerable period and mathematical descriptions of dust capture have allowed rigorous design of static beds. Provision for bed movement and electrostatic augmentation, which allows much thinner continuous beds to be used, requires adaptation of design methods for these phenomena. Design methods that allow for this are developed for a cross-flow bed with vertical bed movement and a number of granule and dust types. Direct current charging is applied to the bed itself and to the particles before they enter the bed. In the case of electrostatic augmentation, it is shown that simple models of spherical particles describe the mechanism adequately. The advantages of pre-charging dust particles before they enter the bed are indicated by calculation and proved experimentally. Parameters to describe the enhancement of filtration efficiency by the collected dust are obtained experimentally. It is shown that the factors controlling re-entrainment vary with particle size. For the dust particles less than 1,5 micrometers in size, re-entrainment is linked closely to the electrostatic capture mechanism which is dominant in that size range. For particles approaching 10 micrometer, re-entrainment can be neglected as the impaction efficiency, which is dominant for particles of this size and larger, approaches unity. A complex situation exists between these particle sizes as the magnitude and predominance of capture mechanisms in this region are determined by a number of operational parameters. It did not prove possible to develop predictive equations for re-entrainment efficiency using the results of this study. A number of heuristics are however developed that allow rational design by the use of the empirical parameters found, and that will be valid for the range of parameters used in this work. / Thesis (PhD(Chemical Engineering))--University of Pretoria, 2006. / Chemical Engineering / unrestricted
278

Étude de l'évaporation d'aérosols liquides semi-volatils collectés sur médias fibreux / Study of the evaporation of liquid semi-volatil aerosols collected on fibrous filters

Sutter, Benjamin 03 November 2009 (has links)
Cette étude s’inscrit dans le cadre de l’amélioration des connaissances liées à l’évaporation d’aérosols liquides semi-volatils collectés sur des filtres à fibres. Le phénomène d’évaporation d’aérosols collectés sur médias fibreux induit des problèmes de sécurité avec notamment une surexposition des salariés aux vapeurs, à l’aval des systèmes généraux de filtration de l’air. De plus, lors des contrôles des concentrations atmosphériques des aérosols, l’évaporation induit une sous-estimation de la phase particulaire de l’aérosol prélevé qui est problématique en termes de prévention de l’exposition. L’objectif de ces travaux a donc été de produire de nombreux résultats expérimentaux afin, d’une part, de compléter les rares présents dans la littérature et, d’autre part, d’améliorer les modèles théoriques développés précédemment. Deux approches expérimentales ont été menées afin d’identifier le processus d’évaporation d’un aérosol collecté. La première, nommée approche globale, permet de suivre l’évaporation de l’aérosol par la quantification des vapeurs à l’aval du filtre, au cours du temps. La seconde, nommée approche microscopique, étudie l’évaporation de gouttes collectées sur les fibres d’une fibre à l’échelle microscopique. Les deux approches réalisées lors de ces travaux s’accordent sur le fait que l’évaporation d’un aérosol liquide semi-volatil ne peut être modélisée par les modèles proposés par la littérature. Des hypothèses ont été avancées afin d’expliquer la divergence de cinétique d’évaporation entre la théorie et les expérimentations / This study falls within the scope of improving knowledge concerning evaporation of semi-volatile liquid aerosols collected on fibrous filters. Under these conditions, the aerosol evaporation phenomenon causes problems of safety, in particular over-exposure of employees to vapours downstream of general air filtering systems. Furthermore, when controlling aerosol atmospheric concentrations, evaporation results in under-estimation of the sampled aerosol particle phase and this is clearly problematic in exposure prevention terms. The aim of this work was therefore to record a large number of experimental data, both to make up for their scarcity in the literature and to improve previously developed theoretical models. Two experimental approaches were implemented to identify the evaporation process for a collected aerosol. The first, termed the global approach, allowed us to monitor aerosol evaporation by measuring vapour quantity downstream of the filter with respect to time. The second, microscopic, approach considers evaporation of droplets collected on the filter fibres on a microscopic scale. The two approaches implemented during this research lead to agreement on the fact that evaporation of a liquid semi-volatile aerosol cannot be satisfactorily represented by the theoretical models proposed in the literature. Hypotheses are advanced to explain the divergence in evaporation kinetics between theoretical and experimental work
279

Étude du colmatage des filtres THE plans et à petits plis par des agrégats de nanoparticules simulant un aérosol de combustion / Experimental study of plane and pleated HEPA filters clogged by particles simulating a combustion aerosol

Bourrous, Soleiman 08 December 2014 (has links)
Dans les installations nucléaires, les particules en suspension sont le vecteur d’une grande partie de la contamination radiologique. Pour cette raison, l'IRSN (Institut de Radioprotection et de Sûreté Nucléaire) étudie les filtres THE (Très Haute Efficacité) plissés qui sont l'un des dispositifs permettant assurer la sécurité de l'exploitation nucléaire. Pour éviter les rejets dans l'environnement, la compréhension du comportement des filtres en particulier dans la situation accidentelle doit être aussi exhaustive que possible. L'accident le plus probable et le plus pénalisant pour les dispositifs de confinement est l’incendie qui conduit à une production massive de particules de suie. Dans ce cas, le colmatage des filtres est un problème qui doit être pris en compte. Jusqu'à présent, une corrélation empirique a été développée pour prédire l'augmentation de perte de charge. Toutefois, le caractère empirique de cette corrélation ne permet pas son utilisation dans toutes les situations. Une compréhension phénoménologique et un modèle de colmatage est alors nécessaire. Le travail de thèse qui suit vise à lier l'évolution de la perte de charge à des observations physiques pour chaque étape du colmatage. Pour ce faire, l'étude a été divisée en deux parties. La première se focalise sur le comportement du filtre plan en mesurant la pénétration de particules à l'intérieur du medium et la porosité du dépôt formé sur sa surface. La deuxième partie consiste en une expérience à petite échelle basée sur un seul pli. L'accumulation de particules à l'intérieur du pli a été directement observée, de plus, la déformation du pli ainsi que les écoulements d'air dans le pli (en utilisant une méthode de PIV) ont été mesurés. Au cours de ces expériences, la perte de charge a été mesurée et les paramètres mesurés ont été liés à l'évolution de la perte de charge. La finalité est de construire un modèle analytique simple afin de prédire l'évolution de la perte de charge des filtres en fonction de la masse déposée, des caractéristiques de l'aérosol et des conditions aérauliques. La principale perspective ouverte par ces résultats est la validation des modèles numériques complets pour surmonter les limites expérimentales. Le prolongement logique de ce travail sera l'étude du comportement d'un filtre colmaté soumis à des contraintes de température, d’humidité et aux agressions chimiques de produits de combustion / In nuclear facilities, airborne particles are the vector of most of the radiological contamination. For this reason, pleated HEPA filters are one of the containment devices which are actively studied by the IRSN (Institut de Radioprotection et de Sûreté Nucléaire) to ensure the safety of nuclear exploitation. To avoid contamination of the environment, the understanding of the behavior of the filters especially in accidental situation has to be as exhaustive as possible. The most probable accident and the most penalizing for the containment devices is fire which leads to a massive soot particle production. In this case, the clogging of the filters is a problematic which has to be taken into account. Up to now, an empirical correlation has been developed to predict the pressure drop increase. The empirical nature of this correlation doesn’t allow its use in all situations. A phenomenological understanding and model of the clogging is then necessary. The following PhD work aims to reduce the pressure drop evolution to physical observations for each step of the clogging in order to model it on the most physical basis as possible. To do so, the study has been divided in two parts. The first one focusing on the behavior of flat filter by measuring the penetration of particles inside the medium and the porosity of the deposit formed on its surface. In the second part a small scale experiment based on a single pleat has been developed. Accumulation of the particles inside the pleat has been directly observed, deformation of the pleat as well as airflow in the pleat (using a PIV method) has been measured. During these experiments, pressure drop has been monitored and the measured parameters have been linked to the pressure drop evolution. Finality is to build a simple analytical model to predict the pressure drop evolution of the filters as a function of the deposited mass, the aerosol characteristics and the ventilation conditions. The main perspective opened by these results is the validation of complete numerical models to overcome the experimental limits. The logical extension of this work will be the study of the interaction of a clogged filter with temperature, air moisture and chemical aggression
280

Effet de l’injection d’eau de production sur la perméabilité des réservoirs pétroliers non cimentés / Produced water injection effect on the permeability of uncemented oil reservoirs

Feia, Sadok 17 February 2015 (has links)
Des phénomènes de colmatage de la structure granulaire des réservoirs pétroliers sont observés lors de la réinjection d'eau de production dans le réservoir (endommagement hydrique). Le dépôt des particules solides en suspension dans l'eau de production peut engendrer une réduction de la perméabilité du réservoir notamment autour des puits d'injection. Il en résulte une diminution significative de l'injectivité des puits. L'objectif de cette thèse est d'étudier le processus de transport et de dépôt des particules solides dans un réservoir de sable et son influence sur la perméabilité du milieu. Nous étudions également l'influence de certains paramètres tels que : la concentration en particules, le débit d'injection, la taille de particules injectées, la taille des pores du milieu et la rugosité de la surface des grains. La finalité de ce travail est de proposer un modèle prédictif de transport-dépôt-endommagement afin de pouvoir estimer la pérennité du système. Dans ce but, une campagne d'essais expérimentaux est menée sur le processus de transport et de dépôt des particules siliceuses de taille de quelques microns dans une éprouvette de sable dense. Ces essais ont été réalisés sur trois dispositif différents ; deux dispositifs d'injection unidimensionnelle (colonne d'injection et cellule d'injection) et un dispositif d'injection radiale en chambre d'étalonnage en vue de simuler les conditions d'injection en puits. Dans ces essais, les conditions hydrauliques sont contrôlées et la concentration en particules dans la suspension est imposée. Au cours de l'injection, le suivi de l'évolution de la pression interstitielle est réalisé en utilisant des capteurs de pression installés à différents endroits dans le milieu. La concentration des particules dans le fluide sortant est mesurée en utilisant un turbidimètre installé à la sortie du milieu. L'étude expérimentale réalisée sous différentes conditions a permis de mettre en évidence une forte hétérogénéité du dépôt des particules dans le milieu poreux. Cette hétérogénéité se traduit par la formation d'un cake interne et/ou externe au voisinage du point d'injection. L'analyse de ce cake montre un milieu à double porosité avec deux familles de pores correspondant à la porosité interne des agglomérats formés par les particules déposées et la porosité du sable réduite progressivement par le dépôt de ces derniers. Une étude paramétrique a permis de mettre en évidence une distinction entre l'effet des faibles et des fortes concentrations, ainsi que l'importance de l'effet du débit d'injection, de la taille des pores, de la taille des particules de la suspension ainsi que de la rugosité de la surface des grains. Ce travail expérimental s'accompagne d'une modélisation des phénomènes de transport et de dépôt des particules dans un milieu poreux. Dans un premier temps, nous avons utilisé un modèle de convection dans lequel la loi décrivant le dépôt des particules prend en compte la densité des particules déposées ainsi que le relargage des particules. Les paramètres de la loi constitutive de dépôt, ainsi qu'une loi empirique porosité-perméabilité ont été calibrés en simulant les résultats expérimentaux d'essais d'injection en cellule sous différentes conditions. Un nouveau modèle semi analytique basé sur le modèle d'Eylander (1988) a été développé dans lequel nous prenons en compte une distribution spatiale des particules déposées et une double porosité du milieu (cake et milieu granulaire). Cette distribution est inspirée du modèle convection étudié auparavant. La simulation d'essais d'injection en cellule a permis de montrer les capacités du modèle pour la prédiction des variations de la pression en cours de l'essai. Ce modèle permet une prédiction de l'évolution de la perméabilité pendant l'injection de façon plus simple et directement applicable dans l'ingénierie de réservoirs / Hydraulic damage and plugging of the granular structure of oil reservoirs are commonly observed during the re-injection of produced water. These phenomena can lead to a significant decrease of the reservoir permeability around the injectors and affect the injectivity of these wells. The objective of this thesis is to study the transport and deposition process of solid particles in a sand reservoir and its influence on the permeability of the medium. We also study the influence of certain parameters such as particle concentration, injection flow rate, the size of injected particles, the pore size of the medium and the surface roughness of the grains. The aim of this work is to propose a predictive model of transport-deposition-damage in order to estimate the durability of the system. For this purpose, an experimental program was conducted on the transport and deposition process of the siliceous particles of size of a few microns in dense sand specimens. These tests were carried out on three different devices; two one-dimensional injection devices (injection column and injection cell) and a radial injection device in “chambre d'étalonnage” in order to simulate the injection wells conditions. In these tests, the flow conditions are controlled and the concentration of particles in the suspension is imposed. During injection, the monitoring of the evolution of pore pressure is carried out using pressure sensors located in different places in the medium. The particle concentration in the outgoing fluid is measured using a turbidimeter installed at the outlet. The experimental study carried out under different conditions allowed to highlight a highly heterogeneous particle deposition in the porous medium. This heterogeneity results in the formation of an internal and/or external cake in the vicinity of the injection point. The analysis of this cake shows a double porosity medium with two pore families corresponding to the internal porosity of the agglomerates formed by the deposited particles and porosity of the sand gradually reduced by the particles deposition. A parametric study permitted to show a distinction between the effect of low and high particles concentrations, as well as the importance of the effect of injection flow rate, the pore size, the particle size of the suspension and the roughness of the surface of the grains. This experimental work is associated with modelling of transport and deposition of particle in a porous medium. We used first the convection model in which a constitutive law describing the particle deposition takes into account the effects of the deposited particles concentration and the release of particles. The parameters of the particle deposition constitutive law as well as an empirical porosity-permeability law have been calibrated by simulation of the results of injection tests performed in the injection cell under different conditions. A semi-analytical model based on the Eylander (1988) model was developed in which we take into account a spatial distribution of the deposited particles and a double porosity of the medium (cake and granular medium). This distribution is inspired from the results if convection model studied before. The simulation of the results of injection experiments permitted to show the performances of this model for prediction of the pore pressure evolution during the fluid injection. This model allows prediction of the permeability evolution in a simpler and directly applicable manner in the reservoir engineering

Page generated in 0.0269 seconds