Avaliação da resistência das vias aéreas através da técnica do interruptor em pacientes com fibrose cística

Rocha, Alessandra January 2010 (has links)
Estudos para a avaliação da resistência das vias aéreas de pré-escolares com fibrose cística através da técnica do interruptor (Rint) são escassos. Foi realizado um estudo tranversal, com 38 pacientes acompanhados no ambulatório de Fibrose Cística do Hospital São Lucas da Pontifícia Universidade Católica do Rio Grande do Sul. Foram realizadas medida da Rint, seguida da avaliação espirométrica em todos os pacientes, repetindo os testes após o uso de salbutamol para a aferição da resposta ao broncodilatador. Nos resultados, foram encontradas forte correlação entre o inverso da Rint e o volume expiratório forçado no 1º segundo (VEF1), (r=0,8 p<0,001) e moderadas correlações entre o inverso da Rint e o fluxo expiratório forçado entre 25% e 75% da capacidade vital (FEF 25-75), (r=0,74 p<0,001) e entre o inverso da Rint e o índice de massa corporal (IMC), (r=0,62 p<0,001). A acurácia da avaliação da resposta ao broncodilatador pela Rint, foi testada através da curva ROC (Receiver Operator Characteristic Curve),comparando-se com resposta ao broncodilatador na espirometria. Foi obtida uma área de 0,75 para o ponto de corte de -28%, correspondendo a uma sensibilidade de 66% e uma especificidade de 82%. Os achados indicam que a Rint apresenta boa correlação com a espirometria, no entanto a técnica não possui uma acurácia suficiente para substituir a Espirometria na avaliação da resposta ao broncodilatador. / Few studies have been published on airway resistance measurements using the interrupter technique (IT). We performed a cross-sectional study, evaluating 38 children and adolescents with Cystic Fibrosis (CF), followed at the outpatient CF clinic of Hospital São Lucas from Pontifícia Universidade Católica do Rio Grande do Sul. Airway resistance (Rint) was measured by the IT, followed by spirometry in all patients. Measurements were repeated after inhalation of salbutamol in order to evaluate bronchodilator response. There was a strong corelation between inverse Rint and forced expiratory volume in one second (FEV1) (r=0.8, p<0.001) and fair correlations between the inverse Rint and mid expiratory flow (MEF) (r=0.74 p<0.001) and between inverse Rint and body mass index (BMI) (r=0.62 p<0.001). The accuracy of bronchodilator response by the IT was tested through the ROC (reciever operating curve), comparing results with spirometry bronchodilator response. An area of 0.75 under the curve was obtained, for the cutoff point of -28% of Rint, achieving a sensitivity of 66% and a specificity of 82%. The findings suggest that Rint shows good correlation with spirometry parameters, although the IT is not sufficiently acurate to replace spirometry in the evaluation of bronchodilator response.
12

Função pulmonar em idosos

Horta, Suzana Grazzia Vorcaro January 1991 (has links)
Resumo não disponível
13

Efeitos da fração inspirada de oxigênio nos volumes pulmonares regionais após oclusão lobar seletiva em modelo fisiológico de redução volumétrica pulmonar endoscópica com válvulas unidirecionais / Effects of inspired oxygen fraction on regional lung volumes during selective lobar occlusion in a physiological model of endoscopic lung volume reduction with one-way endobronchial valves

Torsani, Vinicius 13 June 2019 (has links)
Introdução - Pacientes com enfisema pulmonar avançado submetidos a redução volumétrica pulmonar endoscópica (ELVR) com válvulas unidirecionais (EBV) apresentam melhores resultados quando o lobo tratado não possui ventilação colateral e atelectasia lobar é alcançada. No entanto, a resposta positiva de desinsuflação está associada a maior ocorrência de pneumotórax nessa população. Recomendações recentes enfatizam a importância de condutas no intra- e pós-operatório que busquem minimizar os riscos associados, porém muito pouco é abordado em relação ao manejo da ventilação mecânica durante a intervenção. Elevada fração inspirada de oxigênio (FiO2) é reconhecida na indução de atelectasia por absorção e pode desempenhar um papel relevante na modulação de redução volumétrica após oclusão seletiva. Atualmente não se monitora os efeitos regionais da ELVR com EBV em tempo real. A tomografia de impedância elétrica (TIE) é uma ferramenta de imagem não-invasiva e sem radiação que fornece dados regionais em tempo real de variação de volume pulmonar por meio de uma cinta de eletrodos aplicadas no tórax. Neste contexto, o objetivo deste estudo é usar a TIE para avaliar a influência da FiO2 na ELVR com EBV em um modelo experimental de pulmão normal suíno, animal que não possui ventilação colateral. Métodos - 5 suínos foram submetidos a um estudo cruzado de oclusão do lobo inferior esquerdo por dois métodos, válvulas unidirecionais (válvulas) e cateter-balão intrabronquial (balão), com FiO2 de 50% e 100% por 15 minutos em cada etapa. O balão serviu como um controle, com oclusão assegurada por visão direta via broncoscópio e medida da pressão expiratória distal à oclusão em um animal representativo. A pressão expiratória positiva final usada foi titulada pela TIE para cada animal e recrutamento alveolar foi realizado ao final de cada etapa para reverter o colapso induzido. Foram analisados o mínimo Z (MinZ), como estimativa do volume pulmonar ao final da expiração, e o DeltaZ, variação cíclica proporcional ao volume corrente, ambos expressos em unidades arbitrárias de variação relativa, desde antes da oclusão (Pré) e em cada minuto do momento da oclusão (T0) até 15 minutos (T15). Em um animal adicional foi realizada aquisição simultânea de tomografia computadorizada (TC) e TIE para quantificação do conteúdo de gás. Em todas as análises as regiões de interesse foram direita (Dir) e esquerda (Esq). Resultados - Houve redução rápida e progressiva do MinZ Esq após oclusão com balão, sendo a magnitude quase 3 vezes maior na FiO2 de 100% comparada a 50% (p < 0,001). Com válvulas a 50% o MinZ Esq apresentou redução inicial, mas teve incremento progressivo de forma que em T15 não mostrou diferença em relação ao Pré (p=0,20). Em média, o MinZ Dir não sofreu alteração significativa. Os dados da TC e pressão distal tiveram padrão similar aos achados de MinZ da TIE. O DeltaZ Esq apresentou redução imediata após oclusão e se manteve estável ao longo dos 15 minutos, sem diferença entre as FiO2 em cada método de oclusão. Conclusão- FiO2 a 100% promove maior taxa de redução volumétrica secundária a oclusão lobar seletiva quando comparado a 50% e a TIE apresentou resultados coerentes e concordantes com métodos complementares / Introduction - Patients with advanced pulmonary emphysema undergoing endoscopic lung volume reduction (ELVR) with one-way endobronchial valves (EBV) present better results when the treated lobe has negative collateral ventilation and lobar atelectasis is achieved. However, the positive response of deflation is associated with a higher occurrence of pneumothorax in this population. Recent recommendations emphasize the importance of intra- and postoperative procedures that seek to minimize the associated risks, but very little is addressed regarding the management of mechanical ventilation during the intervention. High inspired oxygen fraction (FiO2) is known to induce atelectasis by absorption and may play a relevant role in the modulation of volumetric reduction after selective occlusion. Currently, regional effects of ELVR with EBV is not monitored in real-time. Electrical impedance tomography (EIT) is a non-invasive and radiation-free imaging tool that provides regional real-time lung volume variation data by means of an electrode belt applied to the chest. In this context, the objective of this study is to use EIT to evaluate the influence of FiO2 on ELVR with EBV in an experimental normal lung swine model, an animal that lacks collateral ventilation. Methods - Five pigs were used in a crossover study of left lower lobe occlusion by two methods, one-way valves (valves) and intrabronchial balloon catheter (balloon), with FiO2 of 50% and 100% for 15 minutes at each stage. The balloon served as a control, where occlusion was ensured by direct bronchoscopic inspection and allowed a measurement of expiratory pressure distal to the occlusion in a representative animal. The positive end-expiratory pressure used was titrated by EIT for each animal and alveolar recruitment was performed at the end of each step to reverse the induced collapse. Minimum impedance value (MinZ) was recorded as an estimate of end-expiratory lung volume and tidal impedance variation (DeltaZ) as proportional to tidal volume, both expressed in arbitrary units of relative variation, from pre-occlusion (Pre) and every minute since occlusion (T0) up to 15 minutes (T15). In an additional animal, simultaneous acquisition of computed tomography (CT) and EIT was performed to quantify gas content. In all the analysis, regions of interest were right (R) and left (L). Results - There was a rapid and progressive reduction of MinZ-L after occlusion, with almost 3 times greater magnitude in FiO2 100% compared to 50% (p < 0.001). With valves at 50%, the MinZ-L presented initial reduction, but had a progressive increase so that in T15 there was no difference in relation to Pre (p = 0.20). On average, MinZ-R did not change significantly. CT and distal pressure data were consistent with EIT MinZ findings. DeltaZ-L presented immediate reduction after occlusion and remained stable throughout all 15 minutes, with no difference between FiO2 in each method of occlusion. Conclusion- FiO2 of 100% promotes greater rate of volumetric reduction following selective lobar occlusion when compared to 50%, and EIT presented coherent results in agreement with complementary methods
14

Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung model

Couto, Lara Poletto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.
15

Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung model

Lara Poletto Couto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.