• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • Tagged with
  • 21
  • 21
  • 15
  • 15
  • 9
  • 8
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise tomográfica do espaço interalveolar e da espessura da cortical óssea vestibular na região parassinfisária de mandíbulas humanas adultas / Tomographic analysis of the interalveolar space and thickness of the vestibular cortical bone in the parasymphyseal region of adult human mandibles

Uzêda, Sandra de Quadros [UNIFESP] 28 January 2009 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-01-28 / Objetivo: Avaliar o espaco interalveolar e a espessura da cortical ossea vestibular no uso das miniplacas de Champy (Sistema 2.0R) na regiao adjacente ao forame mentual. Metodos: Apos aprovacao pelo Comite de Etica em Pesquisa (CEP 1518/05) da UNIFESP e da UNEB (CEP 211/06) foram utilizadas cinquenta mandibulas secas, de individuos adultos dentados (25 do genero feminino e 25 do genero masculino) com idades entre 33 e 87 anos, pertencentes a colecao de ossos do Laboratorio de Anatomia Humana da Universidade do Estado da Bahia, Brasil. Foram excluidas mandibulas que apresentaram mas-formacoes ou alteracao patologica visivel, macroscopicamente, no corpo da mandibula. Inicialmente foi identificado um ponto (P) localizado 1,25 mm superiormente ao ponto medio da margem superior do forame mentual da mandibula (lado direito: P f e lado esquerdo: P f f). Esta distancia corresponde a metade da largura da ponte da miniplaca de titanio, Sistema 2.0R, que e utilizada superiormente ao forame mentual, a fim de eliminar zonas de tensao, quando do tratamento da fratura mandibular. Apos identificacao do ponto (P), a mandibula foi colocada sobre uma base de acrilico com uma haste vertical, planejada e confeccionada para identificacao dos pontos A L, B L, C L e A h, B h e C h que corresponderam as unidades 4.3; 4.4; 4.5 e 3.3; 3.4; 3.5. Apos a marcacao e perfuracao dos pontos, estes foram preenchidos com guta-percha previamente aquecida, que serviu como marcador para a tomografia computadorizada. A distancia interalveolar e a espessura da cortical ossea foram mensuradas por meio de cortes horizontais de tomografia computadorizada (TC). Resultados: Os dados encontrados foram submetidos a analise estatistica pelo teste t de Student e pelo teste de correlacao de Pearson com p .0,05. Nao foi encontrada espessura suficiente na cortical ossea vestibular para a fixacao adequada dos parafusos, embora houvesse uma distancia interalveolar suficientemente segura para introducao dos mesmos. Conclusoes: Os nossos dados apresentaram uma espessura ossea inferior a requerida pela tecnica de Champy, devido a anatomia da mandibula, na regiao mentual, nao evidenciar espessura ossea suficiente para suportar a colocacao das placas e parafusos da forma que preconiza a tecnica. / Objective: To assess the thickness of the mandibular bone in the interalveolar space corresponding to the dental units 3.3; 3.4; 3.5; 4.3; 4.4, 4.5, in the mental foramen region and the thickness of the bone cortical in the same region and to analyze the viability of fixating Champy miniplates (System 2.0®) with monocortical screws in the direction of the interalveolar space of the units 3.3, 3.4, 3.5, 4.3, 4.4, 4.5. Methods: Fifty dry mandibles of dentate adults (25 females and 25 males) aging from 33 to 87 years were used. These catalogued mandibles were acquired from the Human Anatomy Laboratory from the University of State of Bahia, state of Bahia, Brazil. Mandibles with malformations or macroscopic pathological changes in the body of the mandible were excluded. Initially we identified a point (P) located 1.25mm above the upper margin of the mental foramen of the mandible (right side: P´ and left side: P”). This distance corresponds to half of the width of the bridge of the titanium miniplate, System 2.0® that is generally used above the mental foramen in the Champy technique, whose objective is to eliminate tension zones when treating mandibular fractures. After identifying the (P) point, the mandible was placed over an acrylic base horizontally with a vertical rod, planned and constructed to identify the points A´, B´, C´ and A”, B” and C” which correspond to the units 4.3; 4.4; 4.5 and 3.3; 3.4; 3.5. After marking the points, the interalveolar distances were measured by indirect analysis using axial computed tomography (CT) cuts. After delimiting and perforating the points, these were filled with previously heated gutta-percha that served as a marker in the CT cuts. Five (05) mandibles of the sample were cut in a way as to allow direct biometry with the objective of comparing and validating the CT measurements. Results: The data show that the thickness of the vestibular cortical bone is not enough to adequately implant and fixate the screws even though the interalveolar distance is sufficiently safe to introduce them. The data point towards a deficiency in the bone support required to generate the procedures of the Champy technique since the anatomy of the mandible does not present elements that support placing the plates and screws in the way recommended by the technique. There is no adequate bone support to promote the necessary stability. / TEDE / BV UNIFESP: Teses e dissertações
12

Estudo biomecânico comparativo de sistemas de fixação de 2,0-mm locking e convencionais em fraturas de ângulo em mandíbulas de cordeiro sob esforços em três eixos no espaço / Comparative biomechanical study of locking and conventional 2,0-mm fixation systems on angle fractures in sheep\'s mandibles under stresses on three axes in space

Milton de Siqueira Ferreira Anzaloni Saavedra 23 February 2017 (has links)
O objetivo deste trabalho foi avaliar comparativamente a rigidez vertical, horizontal e de resistência à ruptura, com liberdade de movimentos em três eixos no espaço, de mandíbulas fixadas com sistemas 2,0-mm locking e convencionais com uma ou duas placas, em fraturas unilaterais no ângulo mandibular. Vinte mandíbulas de cordeiro, submetidas a osteotomia reproduzindo fraturas, foram divididas em três grupos: F1PC - placa convencional em linha oblíqua; F2PC - duas placas convencionais de modo monoplanar; FL - placa de sistema locking 2,0mm em linha oblíqua. Foi utilizada máquina de ensaio universal, onde foi acoplado suporte metálico com rodas para as mandíbulas. O sistema foi analisado em três diferentes momentos: pré-osteotomia com mandíbulas hígidas e pós-osteotomia/fixação e resistência à ruptura. Os valores de rigidez foram submetidos a análise de variância (p<0,005). Os valores de rigidez vertical (p< 0,0001), horizontal (p= 0,0005) e resistência a ruptura (p= 0,0001) entre pré e pósosteotomia/ fixação apresentaram uma diminuição significante. Na comparação entre os grupos, houve diferença significante para a rigidez vertical (p= 0,009) e o grupo F2PC apresentou maior rigidez. Na comparação entre os grupos, não houve diferença significante para a rigidez horizontal e para resistência a ruptura. Foi concluído que para rigidez vertical, horizontal e resistência a ruptura os valores de pós-osteotomia/fixação foram significantemente menores, o sistema de fixação com duas placas convencionais mostrou maior resistência quanto à rigidez vertical que os demais sistemas e não houve diferença estatisticamente significante na comparação entre os grupos quanto a rigidez horizontal e resistência a ruptura. / The objective of this work was to evaluate the vertical, horizontal and tensile rigidity with freedom of movement in three axes in space, of mandibles fixed with 2.0-mm locking and conventional systems with one or two plates, in unilateral fractures in the Angle of the mandible. Twenty mandibles of lamb, submitted to osteotomy and reproducing fractures, were divided into three groups: F1PC - conventional oblique line; F2PC - two conventional single-mode boards; FL - 2.0mm locking system plate in oblique line. A universal test machine was used, where metal support was coupled with wheels for the jaws. The system was analyzed in three different moments: pre-osteotomy with healthy mandibles and post-osteotomy / fixation and resistance to rupture. The stiffness values were submitted to analysis of variance (p <0.005). The values of vertical rigidity (p <0.0001), horizontal (p = 0.0005) and resistance to rupture (p = 0.0001) between pre and post osteotomy / fixation showed a significant decrease. In the comparison between the groups, there was a significant difference for vertical stiffness (p = 0.009) and the F2PC group presented greater stiffness. In the comparison between the groups, there was no significant difference for horizontal rigidity and for resistance to rupture. It was concluded that for post-osteotomy / fixation values were significantly lower for vertical, horizontal and tensile rigidity, the fixation system with two conventional plates showed greater resistance to vertical rigidity than the other systems and there was no statistically significant difference in comparison between the groups for horizontal rigidity and resistance to rupture.
13

Avaliação dos resultados do uso de haste inflavel auto blocante intramedular (HEIA) para o tratamento de fraturas e falhas de fixação ossea dos ossos longos / Clinical and radiological results from the of a self-locking intramedullary expanding nailing system (SLINS) fixion 'trade mark' for treating failures in long bone fractures

Ravaglia, Fabio Ferraz do Amaral 29 May 2008 (has links)
Orientador: Alberto Cliquet Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T22:08:58Z (GMT). No. of bitstreams: 1 Ravaglia_FabioFerrazdoAmaral_M.pdf: 3548953 bytes, checksum: 43be45b122388651863a7129f73a3c73 (MD5) Previous issue date: 2008 / Mestrado / Cirurgia / Mestre em Cirurgia
14

Ocorrência de traumatismo raquidiano em doentes em coma decorrente de traumatismo cranioencefálico / Spine injuries in patents presenting coma due to head injury

Rosi Junior, Jefferson 05 April 2012 (has links)
Foi realizado estudo prospectivo com o objetivo de se determinar a ocorrência de traumatismo raquidiano (TR) em 355 doentes em coma decorrente de traumatismo cranioencefálico (TCE) resultante de acidente de tráfego atendidos no Pronto Socorro de Neurocirurgia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (PSNCHCFMUSP) de 1° de setembro de 2003 a 31 de dezembro de 2009. Todos os doentes foram submetidos ao exame físico e neurológico e à tomografia computadorizada (TC) do corpo inteiro para diagnosticar-se e avaliar-se a gravidade das lesões traumáticas encefálicas, vertebrais ou de outras regiões no momento da admissão ao PSNCHCFMUSP. Em 69 (19,4%) doentes, foi(ram) diagnosticada(s) lesão(ões) na coluna vertebral com o exame de TC da coluna vertebral. As idades dos doentes variaram de 12 a 55 anos (média de 29,0 anos). Eram do sexo masculino 57 (82,6%) doentes. As causas do(s) traumatismo(s) foi(ram) acidente(s) envolvendo motocicleta em 28 (40,6%) casos, atropelamento em 21 (30,5%), colisão de automóvel, caminhão ou caminhonete, em 18 (26,1%) ou acidente com bicicleta em dois (2,9%). Hemorragia subaracnóidea traumática foi a anormalidade intracraniana traumática mais evidenciada no exame de TC do crânio; ocorreu em 57 (82,6%). O(s) processo(s) transverso(s) foi(ram) o(s) segmento(s) vertebral(is) mais acometido(s) pela(s) fratura(s). A sétima vértebra cervical foi a mais lesada; nela identificaram-se fraturas em 24 (34,8%) doentes. Evidenciou-se que a distribuição das fraturas foi similar ao longo das demais vértebras da coluna cervical, quatro primeiras vértebras torácicas e vértebras lombares. Em oito (11,6%) doentes a(s) lesão(ões) neurológica(s) foi(ram) classificada(s) como Frankel A, e nos demais 61(88,4%), como Frankel não-A. Houve necessidade de cirurgia espinal em 24 (34,8%) doentes e de neurocirurgia craniana em 18 (26,0%) doentes. A Escala de Recuperação de Glasgow foi aplicada para avaliar-se as condições neurológicas do doente no momento da alta hospitalar e revelou ocorrência de óbito em dois (2,9%) doentes. Concluiuse que é recomendada a avaliação clínica e também com métodos de imagem da coluna vertebral nos doentes em coma decorrente de TCE / The author presents a prospective study aiming the evaluation of coexistence of spinal injury (SI) in 355 patients presenting coma due to craniocerebral trauma assisted at the Emergency Room of the Hospital das Clínicas of the University of São Paulo Medical School, from September, 1st, 2003 to december, 31th,2009. All patients underwent physical and neurological examination and had computed tomography (CT) scanning of the entire body to diagnose and evaluate the severity of brain and spinal injury at the time of admission. Traumatic lesions of the spine were diagnosed in 69 (19.4%) patients. The ages of patients ranged from 12 to 55 years (mean = 29,0 years).The SI predominated in males, corresponding to 57 (82.6%) patients. The causes of the trauma were motorcycle accident in 28 (40.6%) cases, running over in 21(30.5%), car collision 18 (26.1%) cases and bicycle accident in two (2.9%). Traumatic subarachnoid hemorrhage was the most common traumatic intracranial abnormality in the CT images; it was identified in 57 (82.6%) patients. The transverse process was the most common vertebral part presenting fracture(s). The 7th cervical vertebra was individually the most commonly affected; traumatic lesion of this vertebra presented in 24 (34.8%) patients. The diagnosis of fracture(s) was similar in the other cervical vertebrae and occurred also in the first four thoracic and in the lumbar vertebrae. Severe neurological deficit secondary to spine fracture was diagnosed in eight (11.6%) patients, classified as Frankel A. The others 61(88.4%) patients did not present complete spinal cord or spinal roots neurological deficits were classified as Frankel non A. The Recovery Scale of Glasgow was used to evaluate the neurological status at discharge from hospital. Two (2.9%) patients died. Spinal surgery was necessary in 24 (34.8%) patients and cranial surgery in 18 (26.0%). It was concluded that in addition to clinical evaluation, the CT imaging of the spine is recommended in patients in coma due to mechanical traumatic head injury
15

Avaliação da escala MESS nas fraturas expostas da perna / MESS score evaluation in open leg fractures

Torres, Luciano Ruiz 18 September 2017 (has links)
INTRODUÇÃO: A escala MESS foi um instrumento desenvolvido para auxiliar o cirurgião na decisão entre amputar e preservar o membro inferior gravemente lesado. Neste estudo acompanhamos um grupo de pacientes com fratura exposta dos ossos da perna com MESS >= sete, preditivo para amputação, durante seu tratamento até a sua reabilitação completa. OBJETIVO: O objetivo do estudo foi determinar a relação de sucesso/insucesso funcional nos pacientes com escore MESS >= sete com o membro reconstruído no longo prazo (mínimo de dez anos de seguimento). MÉTODOS: Foram incluídos no estudo, os pacientes com fratura exposta Gustilo IIIB e IIIC dos ossos da perna com critérios de membros inferiores gravemente lesados modificados de Gregory e Bonanni e escore MESS >= sete. Os pacientes foram incluídos no período de 2003-2006. Os pacientes foram avaliados através da Medida de Independência Funcional e escala de incapacidade pela dor. RESULTADOS: Dos 26 pacientes selecionados, foram realizadas amputações em cinco e preservação do membro acometido, após intervenções, em 21 pacientes. Nove pacientes foram reavaliados após mais de 10 anos de seguimento. Destes, sete apresentavam o membro preservado e apenas um teve a reconstrução considerada como falha. Dos pacientes preservados, o paciente com fratura exposta Gustilo IIIC teve a reconstrução considerada falha. As duas amputações também foram consideradas funcionais. CONCLUSÃO: A escala MESS não é um bom instrumento para indicar amputação / INTRODUCTION: The MESS score was designed as a tool to assist the surgeon in deciding between amputate or preserve the severely injured lower limb. In this study we followed patients with severe open fractures of the leg with MESS >= seven, predictive for amputation during their treatment until their complete rehabilitation. OBJETIVE: The aim of the study was to determine the relative success / failure in patients with functional MESS score >= seven with the reconstructed member. METHODS: We included in the study, patients with open fractures Gustilo IIIB and IIIC of the leg with criteria for seriously injured lower limb modified by Gregory and Bonanni and MESS score >= seven. All patients were included from 2003 to 2006. Patients were evaluated through the Functional Independence Measure and Pain Disability Index. RESULTS: From selected 26 patients, five had below knee amputation and 21 after reconstructive procedures got limb salvage. Nine patients were evaluated after 10 years follow-up. Seven of them have the reconstructed limb, only one of these was considered as functional failure. Of the patients with lower limb reconstruction only Gustilo IIIC open fracture has a non-functional member. The two patients with amputation also have functional results. CONCLUSION: MESS is not a proper instrument to indicate amputation
16

Estudo prospectivo da utilização do sistema de placas e parafusos 2.0-mm locking comparado com sistemas convencionais no tratamento de fraturas mandibulares / A prospective study of the use of 2.0-mm locking system plates compared with standard systems in the treatment of mandibular fractures

Camino Junior, Rubens 29 September 2016 (has links)
Um sistema mais adequado de fixação interna no tratamento de fraturas mandibulares é essencial para um bom resultado. Foi realizado um estudo comparativo da utilização do sistema de fixação 2.0-mm locking com sistemas convencionais no tratamento de fraturas mandibulares. Para este estudo, 87 pacientes consecutivos com 134 fraturas mandibulares foram divididos aleatoriamente para receber placas 2.0-mm locking (n = 45) ou convencionais 2.0-mm ou 2.4-mm (n = 42) e tiveram um seguimento mínimo de 6 meses. Foram obtidos dados pessoais, presença de doenças sistêmicas, abuso de substâncias, etiologia, politraumatismo e as localizações. As fraturas foram classificadas com base no grau de deslocamento e de complexidade. Foi mensurada a amplitude da abertura bucal. Análises estatísticas foram feitas na comparação entre grupos (p<= 0,050). Houve maior faixa etária (p = 0,010) e mais distúrbios gerais (p< 0,001) no Grupo Locking. Houve maior gravidade das fraturas (p= 0,004) no Grupo Convencional. Houve diferença significante para a localização das fraturas (p = 0,009), com mais casos na região de corpo no Grupo Locking. Houve aumento progressivo dos valores da abertura bucal, com diferença significante em ambos os grupos (p<= 0,050), sendo que o convencional apresentou melhor recuperação (47,2 ± 8,9 mm). Um caso de complicação pós-operatória maior ocorreu no Grupo Locking (2,2%) e três casos no Grupo Convencional (7,1%). Foi observado que o sistema 2.0-mm locking mostrou melhores resultados clínicos, pois ocorreu apenas um caso de complicação maior, porém o grupo convencional mostrou recuperação mais rápida da abertura bucal e, que também foi constatado que o sistema 2.0-mm locking foi efetivo no tratamento de fraturas desfavoráveis que necessitariam do sistema 2.4-mm convencional. / A more adequate system of internal fixation in the treatment of mandibular fractures is essential for a good result. A comparative study of the use of the 2.0-mm locking fixation system with conventional systems in the treatment of mandibular fractures was performed. For this study, 87 consecutive patients with 134 mandibular fractures were randomized to receive 2.0-mm locking plates (n = 45) or conventional 2.0-mm or 2.4-mm plates (n = 42) and had a minimum follow-up of 6 months. Fractures were classified based on the degree of displacement and complexity. The amplitude of mouth opening was measured. Statistical analyses were performed to compare groups (p <= 0.050). There were older age (p = 0.010) and more substance abuse (p = 0.001) in the Locking group. There was more complex fractures (p = 0.017) and teeth in the fracture line (p = 0.044) in the conventional group. There was a significant difference for the location of fractures (p = 0.009), with more cases in the body region in the Locking group. There was a progressive increase in the values of mouth opening, with a significant difference in both groups (p <= 0.050), whereas the conventional group showed better recovery (47.2 ± 8.9 mm). A case of major postoperative complication occurred in the Locking Group (2.2%) and three cases in the conventional group (7.1%). The 2.0-mm locking system showed better clinical outcomes because there was only one case of major complications and was effective in the treatment of unfavorable fractures that would require the conventional system 2.4-mm but the group treated with conventional systems showed faster recovery of mouth opening.
17

Estudo prospectivo da utilização do sistema de placas e parafusos 2.0-mm locking comparado com sistemas convencionais no tratamento de fraturas mandibulares / A prospective study of the use of 2.0-mm locking system plates compared with standard systems in the treatment of mandibular fractures

Rubens Camino Junior 29 September 2016 (has links)
Um sistema mais adequado de fixação interna no tratamento de fraturas mandibulares é essencial para um bom resultado. Foi realizado um estudo comparativo da utilização do sistema de fixação 2.0-mm locking com sistemas convencionais no tratamento de fraturas mandibulares. Para este estudo, 87 pacientes consecutivos com 134 fraturas mandibulares foram divididos aleatoriamente para receber placas 2.0-mm locking (n = 45) ou convencionais 2.0-mm ou 2.4-mm (n = 42) e tiveram um seguimento mínimo de 6 meses. Foram obtidos dados pessoais, presença de doenças sistêmicas, abuso de substâncias, etiologia, politraumatismo e as localizações. As fraturas foram classificadas com base no grau de deslocamento e de complexidade. Foi mensurada a amplitude da abertura bucal. Análises estatísticas foram feitas na comparação entre grupos (p<= 0,050). Houve maior faixa etária (p = 0,010) e mais distúrbios gerais (p< 0,001) no Grupo Locking. Houve maior gravidade das fraturas (p= 0,004) no Grupo Convencional. Houve diferença significante para a localização das fraturas (p = 0,009), com mais casos na região de corpo no Grupo Locking. Houve aumento progressivo dos valores da abertura bucal, com diferença significante em ambos os grupos (p<= 0,050), sendo que o convencional apresentou melhor recuperação (47,2 ± 8,9 mm). Um caso de complicação pós-operatória maior ocorreu no Grupo Locking (2,2%) e três casos no Grupo Convencional (7,1%). Foi observado que o sistema 2.0-mm locking mostrou melhores resultados clínicos, pois ocorreu apenas um caso de complicação maior, porém o grupo convencional mostrou recuperação mais rápida da abertura bucal e, que também foi constatado que o sistema 2.0-mm locking foi efetivo no tratamento de fraturas desfavoráveis que necessitariam do sistema 2.4-mm convencional. / A more adequate system of internal fixation in the treatment of mandibular fractures is essential for a good result. A comparative study of the use of the 2.0-mm locking fixation system with conventional systems in the treatment of mandibular fractures was performed. For this study, 87 consecutive patients with 134 mandibular fractures were randomized to receive 2.0-mm locking plates (n = 45) or conventional 2.0-mm or 2.4-mm plates (n = 42) and had a minimum follow-up of 6 months. Fractures were classified based on the degree of displacement and complexity. The amplitude of mouth opening was measured. Statistical analyses were performed to compare groups (p <= 0.050). There were older age (p = 0.010) and more substance abuse (p = 0.001) in the Locking group. There was more complex fractures (p = 0.017) and teeth in the fracture line (p = 0.044) in the conventional group. There was a significant difference for the location of fractures (p = 0.009), with more cases in the body region in the Locking group. There was a progressive increase in the values of mouth opening, with a significant difference in both groups (p <= 0.050), whereas the conventional group showed better recovery (47.2 ± 8.9 mm). A case of major postoperative complication occurred in the Locking Group (2.2%) and three cases in the conventional group (7.1%). The 2.0-mm locking system showed better clinical outcomes because there was only one case of major complications and was effective in the treatment of unfavorable fractures that would require the conventional system 2.4-mm but the group treated with conventional systems showed faster recovery of mouth opening.
18

Ocorrência de traumatismo raquidiano em doentes em coma decorrente de traumatismo cranioencefálico / Spine injuries in patents presenting coma due to head injury

Jefferson Rosi Junior 05 April 2012 (has links)
Foi realizado estudo prospectivo com o objetivo de se determinar a ocorrência de traumatismo raquidiano (TR) em 355 doentes em coma decorrente de traumatismo cranioencefálico (TCE) resultante de acidente de tráfego atendidos no Pronto Socorro de Neurocirurgia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (PSNCHCFMUSP) de 1° de setembro de 2003 a 31 de dezembro de 2009. Todos os doentes foram submetidos ao exame físico e neurológico e à tomografia computadorizada (TC) do corpo inteiro para diagnosticar-se e avaliar-se a gravidade das lesões traumáticas encefálicas, vertebrais ou de outras regiões no momento da admissão ao PSNCHCFMUSP. Em 69 (19,4%) doentes, foi(ram) diagnosticada(s) lesão(ões) na coluna vertebral com o exame de TC da coluna vertebral. As idades dos doentes variaram de 12 a 55 anos (média de 29,0 anos). Eram do sexo masculino 57 (82,6%) doentes. As causas do(s) traumatismo(s) foi(ram) acidente(s) envolvendo motocicleta em 28 (40,6%) casos, atropelamento em 21 (30,5%), colisão de automóvel, caminhão ou caminhonete, em 18 (26,1%) ou acidente com bicicleta em dois (2,9%). Hemorragia subaracnóidea traumática foi a anormalidade intracraniana traumática mais evidenciada no exame de TC do crânio; ocorreu em 57 (82,6%). O(s) processo(s) transverso(s) foi(ram) o(s) segmento(s) vertebral(is) mais acometido(s) pela(s) fratura(s). A sétima vértebra cervical foi a mais lesada; nela identificaram-se fraturas em 24 (34,8%) doentes. Evidenciou-se que a distribuição das fraturas foi similar ao longo das demais vértebras da coluna cervical, quatro primeiras vértebras torácicas e vértebras lombares. Em oito (11,6%) doentes a(s) lesão(ões) neurológica(s) foi(ram) classificada(s) como Frankel A, e nos demais 61(88,4%), como Frankel não-A. Houve necessidade de cirurgia espinal em 24 (34,8%) doentes e de neurocirurgia craniana em 18 (26,0%) doentes. A Escala de Recuperação de Glasgow foi aplicada para avaliar-se as condições neurológicas do doente no momento da alta hospitalar e revelou ocorrência de óbito em dois (2,9%) doentes. Concluiuse que é recomendada a avaliação clínica e também com métodos de imagem da coluna vertebral nos doentes em coma decorrente de TCE / The author presents a prospective study aiming the evaluation of coexistence of spinal injury (SI) in 355 patients presenting coma due to craniocerebral trauma assisted at the Emergency Room of the Hospital das Clínicas of the University of São Paulo Medical School, from September, 1st, 2003 to december, 31th,2009. All patients underwent physical and neurological examination and had computed tomography (CT) scanning of the entire body to diagnose and evaluate the severity of brain and spinal injury at the time of admission. Traumatic lesions of the spine were diagnosed in 69 (19.4%) patients. The ages of patients ranged from 12 to 55 years (mean = 29,0 years).The SI predominated in males, corresponding to 57 (82.6%) patients. The causes of the trauma were motorcycle accident in 28 (40.6%) cases, running over in 21(30.5%), car collision 18 (26.1%) cases and bicycle accident in two (2.9%). Traumatic subarachnoid hemorrhage was the most common traumatic intracranial abnormality in the CT images; it was identified in 57 (82.6%) patients. The transverse process was the most common vertebral part presenting fracture(s). The 7th cervical vertebra was individually the most commonly affected; traumatic lesion of this vertebra presented in 24 (34.8%) patients. The diagnosis of fracture(s) was similar in the other cervical vertebrae and occurred also in the first four thoracic and in the lumbar vertebrae. Severe neurological deficit secondary to spine fracture was diagnosed in eight (11.6%) patients, classified as Frankel A. The others 61(88.4%) patients did not present complete spinal cord or spinal roots neurological deficits were classified as Frankel non A. The Recovery Scale of Glasgow was used to evaluate the neurological status at discharge from hospital. Two (2.9%) patients died. Spinal surgery was necessary in 24 (34.8%) patients and cranial surgery in 18 (26.0%). It was concluded that in addition to clinical evaluation, the CT imaging of the spine is recommended in patients in coma due to mechanical traumatic head injury
19

Avaliação da escala MESS nas fraturas expostas da perna / MESS score evaluation in open leg fractures

Luciano Ruiz Torres 18 September 2017 (has links)
INTRODUÇÃO: A escala MESS foi um instrumento desenvolvido para auxiliar o cirurgião na decisão entre amputar e preservar o membro inferior gravemente lesado. Neste estudo acompanhamos um grupo de pacientes com fratura exposta dos ossos da perna com MESS >= sete, preditivo para amputação, durante seu tratamento até a sua reabilitação completa. OBJETIVO: O objetivo do estudo foi determinar a relação de sucesso/insucesso funcional nos pacientes com escore MESS >= sete com o membro reconstruído no longo prazo (mínimo de dez anos de seguimento). MÉTODOS: Foram incluídos no estudo, os pacientes com fratura exposta Gustilo IIIB e IIIC dos ossos da perna com critérios de membros inferiores gravemente lesados modificados de Gregory e Bonanni e escore MESS >= sete. Os pacientes foram incluídos no período de 2003-2006. Os pacientes foram avaliados através da Medida de Independência Funcional e escala de incapacidade pela dor. RESULTADOS: Dos 26 pacientes selecionados, foram realizadas amputações em cinco e preservação do membro acometido, após intervenções, em 21 pacientes. Nove pacientes foram reavaliados após mais de 10 anos de seguimento. Destes, sete apresentavam o membro preservado e apenas um teve a reconstrução considerada como falha. Dos pacientes preservados, o paciente com fratura exposta Gustilo IIIC teve a reconstrução considerada falha. As duas amputações também foram consideradas funcionais. CONCLUSÃO: A escala MESS não é um bom instrumento para indicar amputação / INTRODUCTION: The MESS score was designed as a tool to assist the surgeon in deciding between amputate or preserve the severely injured lower limb. In this study we followed patients with severe open fractures of the leg with MESS >= seven, predictive for amputation during their treatment until their complete rehabilitation. OBJETIVE: The aim of the study was to determine the relative success / failure in patients with functional MESS score >= seven with the reconstructed member. METHODS: We included in the study, patients with open fractures Gustilo IIIB and IIIC of the leg with criteria for seriously injured lower limb modified by Gregory and Bonanni and MESS score >= seven. All patients were included from 2003 to 2006. Patients were evaluated through the Functional Independence Measure and Pain Disability Index. RESULTS: From selected 26 patients, five had below knee amputation and 21 after reconstructive procedures got limb salvage. Nine patients were evaluated after 10 years follow-up. Seven of them have the reconstructed limb, only one of these was considered as functional failure. Of the patients with lower limb reconstruction only Gustilo IIIC open fracture has a non-functional member. The two patients with amputation also have functional results. CONCLUSION: MESS is not a proper instrument to indicate amputation
20

Estudo comparativo entre dois métodos de tratamento da lesão do ligamento cruzado posterior por avulsão óssea na tíbia : amarrilho artroscópico e fixação com parafuso por via posterior aberta / Comparative study between two methods of treatment of tibial posterior cruciate ligament bony avulsion: arthroscopic suture and screw fixation using open posterior approach.

Sasaki, Sandra Umeda 15 December 2003 (has links)
Atualmente, os bons resultados na lesão do ligamento cruzado posterior por avulsão óssea na tíbia associam-se ao tratamento cirúrgico e precoce. A técnica convencional é a fixação com parafuso pela via de acesso posterior do joelho, com abordagem direta das estruturas vasculares e nervosas da região. Neste estudo experimental em 20 joelhos de cadáveres, buscamos apresentar uma alternativa com amarrilho por via artroscópica, comparando-o com a técnica convencional, através da inspeção direta e de testes biomecânicos. Houve falha na fixação de apenas um exemplar de cada método e medidas de deslocamento tibial posterior (p=0,23) e rigidez média (p=0,28) sem diferenças significativas entre as duas técnicas. Concluímos ser o amarrilho artroscópico viável e uma alternativa no tratamento desta lesão. / Nowadays, good results on the management of posterior cruciate ligament bony avulsion of the tibia are associated with early surgical repair. The usual method of treatment is the open posterior approach with screw fixation, wich requires popliteal neurovascular bundle direct manipulation. This study presents a new arthroscopic suture and compares it with the conventional technique, using biomechanical tests and direct inspection in cadaveric specimens (20 knees). On both methods there was a fixation fail in one knee. The analisys of tibial posterior displacement (p=0,23) and stiffness (p=0,20) were similar for the two methods. The Arthroscopic suture presented is an effective reattachment method for this fracture pattern.

Page generated in 0.0798 seconds