• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • 42
  • 11
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 138
  • 138
  • 138
  • 66
  • 62
  • 60
  • 57
  • 54
  • 19
  • 19
  • 18
  • 17
  • 17
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Análise de sulfitos em sucos de frutas e estimativa de seu consumo por escolares / Analytical determination of sulphites in fruit juices and estimation of their intake by students

Welliton Donizeti Popolim 11 May 2009 (has links)
No Brasil os dados sobre a utilização dos sulfitos pela indústria de alimentos e pesquisas sobre o seu consumo são escassos. Sendo assim, o objetivo desta pesquisa foi avaliar o nível de sulfitos em sucos de frutas e estimar seu consumo por escolares de 5ª. a 8ª. séries de escolas públicas, do ensino fundamental, do município de São Caetano do Sul-SP, Brasil. Foi aplicado questionário de freqüência de consumo de alimentos (QFCA) em 313 escolares, sendo 56,9 % do sexo feminino e 43,1 % do sexo masculino, com média de idade de 14,7 anos. Os alimentos sulfitados mais consumidos foram os néctares ou sucos de frutas, o açúcar refinado, as batatas fritas congeladas, o coco ralado, o suco de caju e as frutas secas e cristalizadas. Considerando os limites máximos permitidos (LMP) pela legislação brasileira, o consumo de SO2, em mg SO2/kg pc/dia, foi de 0,12 mg SO2/kg pc/dia, sendo que este valor médio corresponde a 17% da IDA (0,7 mg SO2/kg pc/dia). Já os resultados das análises dos sucos de frutas demonstram que a análise por injeção em fluxo (Flow injection analysis - FIA) modificada obteve resultados de sulfitos nas amostras analisadas com menor variação do que aqueles obtidos pelo método Monier-Williams (M-W) otimizado, e que nenhuma amostra ultrapassou os LMP. / In Brazil there are no data on use of sulphites by the food industry and research on their consumption by population. Thus, the objective of this research was to evaluate sulphites in fruits juices and estimate intake sulphites in a group of 5th 8th schoolchildren of public schools in São Caetano do Sul-SP, Brazil. It was applied a food frequency questionnaire (FFQ) at 313 schoolchildrens (56.9% female, 43.1% male and average age 14.7 years). Sulphited products identified were fruits juices, sugar, frozen chips, grated coconut, cashew juice and dried fruits. Considering maximum permitted levels (MPL) stabilished by Brazilian legislation, none of the students exceeded the ADI of 0.70 mg SO2/kg bw/day, with average of consumption of 0.12 mg SO2/kg bw/day (17 % of the ADI). The results of the fruits juices analysis demonstrated flow injection analysis (FIA) modified obtained better results than optimized Monier-Williams method (M-W) and no sample exceeded the MPL.
122

Projeto e desenvolvimento de um sistema de análises químicas por injeção em fluxo para determinações espectrofotométricas simultâneas de cobre e de níquel explorando cinética diferencial e calibração multivariada / Project and development of a flow-injection system for simultaneous spectrophotometric determination of copper and nickel exploiting differential kinetics and multivariate calibration

Milton Katsumi Sasaki 09 June 2011 (has links)
Análise cinética diferencial explora diferenças em taxas reacionais entre os analitos e um sistema reacional comum; etapas de separação prévia dos analitos podem então ser prescindidas. Sistemas de análise por injeção em fluxo (FIA) se afiguram como uma ferramenta importante para métodos envolvendo essa estratégia, pois permitem um controle preciso da dispersão de reagentes / amostras e da temporização. O objetivo deste trabalho foi então explorar estes dois aspectos favoráveis visando a determinação simultânea de cobre e de níquel, a partir de suas reações com o reagente cromogênico 5-Br-PADAP. Três alíquotas de amostra eram simultaneamente inseridas, por meio de um injetor proporcional, no fluxo transportador reagente (5-Br-PADAP 75 mg L-1 + sistema tampão 0,5 mol L-1 em ácido acético / acetato, pH 4,7) de um sistema FIA em linha única. Durante o transporte em direção ao detector, as zonas estabelecidas se coalesciam, originando uma zona complexa que era monitorada a 562 nm. Os valores locais máximos e mínimos da função concentração / tempo obtida eram considerados para calibração multivariada utilizando a ferramenta quimiométrica PLS-2 (partial least squares - 2). A concentração do reagente, a capacidade tampão, a temperatura, a vazão, os comprimentos do percurso analítico e das alças de amostragem, bem como a distância inicial entre as zonas de amostra estabelecidas foram avaliados para construção dos modelos matemáticos. Estes foram criados a partir de 24 soluções-padrão mistas de Cu2+ e Ni2+ (0,00-1,60 mg L-1 em HNO3 a 0,1% v/v). Duas variáveis latentes foram suficientes para capturar > 98 % das variâncias inerentes ao conjunto de dados e erros médios das previsões (RMSEP) foram estimados em 0,025 e 0,071 mg L-1 para Cu e Ni, salientando a boa precisão do modelo de calibração. O sistema proposto apresenta boas figuras de mérito: fisicamente estável, quando mantido em operação por quatro horas ininterruptas, consumo de 314 \'mü\'g 5-Br-PADAP por amostra, frequência analítica de 33 amostras por hora (165 dados, 66 determinações) e erros nas leituras em sinais de absorbância tipicamente < 5%. Entretanto, verificou-se a inexatidão das previsões efetuadas pelo modelo proposto, quando comparadas aos resultados obtidos por ICP OES. A partir deste fato, tornam-se necessários maiores estudos referentes a este tipo de matriz, bem como de técnicas de mascaramento dos possíveis interferentes presentes / Differential kinetic analysis exploits the differences in reaction rates between the analytes and a common reactant system; prior steps of analyte separation can then be waived. Flow-injection systems (FIA) are considered as an important tool for methods involving such a strategy because they allow precise control of sample / reagent dispersion and timing. The aim of this work was then to exploit these two favorable aspects for the simultaneous determination of copper and nickel using the 5-Br-PADAP chromogenic reagent. Three sample aliquots were simultaneously inserted by means of a proportional injector into reagent carrier stream (75 mg L-1 5-Br-PADAP + 0.5 mol L-1 acetic acid / acetate, pH 4.7) of a single-line FIA system. During transport towards detection, the established zones coalesce themselves, resulting in a complex zone that was monitored at 562 nm. The local maximum and minimum values of the concentration / time obtained function were considered for multivariate calibration using the PLS-2 (partial least squares - 2) chemometric tool. The reagent concentration, buffering capacity, temperature, flow rate and lengths of the analytical path, sampling loops and initial distance between plugs were established and evaluated for the construction of mathematical models. To this end, 24 Cu2+ and Ni2+ (0.00 - 1.60 mg L-1, also 0.1% v/v HNO3) mixed standard solutions were used. Two latent variables were enough to capture > 98% of the variance inherent in the data set and average prediction errors (RMSEP) were estimated as 0.025 and 0.071 mg L-1 for Cu and Ni, emphasizing the good precision the calibration model. The proposed system presents good figures of merit: physical stability when kept in operation for four uninterrupted hours, consumption of 314 \'mü\'g 5-Br-PADAP per sample, sample throughput of 33 h-1 (165 data, 66 determinations) and error readings in absorbance signals typically <5%. However, inaccuracy of the predictions made by the proposed model when compared to results obtained by ICP OES was noted. Thus, further studies involving this type of matrix, as well as masking techniques of potential interferences present, are recommended
123

Sistemas de análises químicas em fluxo explorando mecanismos de re-alimentação, calibração multivariada e outras abordagens para melhoria em desempenho / Flow systems exploiting feed-back mechanisms, multivariate calibration and other strategies for improving the analytical performance

Paula Regina Fortes 30 June 2010 (has links)
Estudos foram conduzidos relativamente ao desempenho dos sistemas de análises em fluxo quando configurados como sistemas inteligentes, associados às técnicas de calibração multivariada ou empregando nanocristais como sensibilizadores. Ainda, melhorias relacionadas às modificações dos fluxos foram avaliadas, especialmente no que se refere à diálise em linha. Neste sentido, foi proposta uma nova estratégia para implementar determinações simultâneas de ferro e vanádio em ligas metálicas envolvendo cinética diferencial. O método baseava-se nas diferentes influências exercidas por Fe2+ e por V4+ na taxa de oxidação de íons iodeto por íons Cr6+ sob condições ácidas. Três diferentes alíquotas de amostra eram inseridas em um fluxo transportador / reagente de KI, confluindo posteriormente com um fluxo de K2Cr2O7. A sobreposição entre as três zonas de amostra estabelecidas resultava em uma zona de amostra complexa com diversos valores de absorbância. Medidas realizadas nos pontos de máximos e minímos do sinal registrado eram mais precisas e continham informações acerca dos diferentes estágios de desenvolvimento da reação e de diferentes condições de concentrações. Em outra estratégia, um sistema MPFS inteligente foi proposto para a determinação turbidimétrica sequencial de sulfato e cloreto em águas naturais. Ambos os métodos foram implementados no mesmo módulo de análises, proporcionando facilidades relativas ao: preparo de amostra em linha; adição de íons sulfato ou cloreto ao meio reacional para melhoria das condições de supersaturação; decisão em tempo real acerca da necessidade ou não da próxima análise. Inicialmente, determinava-se a concentração de cloreto presente na amostra, e este resultado era comparado com um valor pré-determinado. Se este fosse superior, a amostra era analisada novamente visando à determinação de sulfato. Caso contrário, uma nova amostra era analisada. A estratégia resultou em aumento da velocidade analítica e em boas figuras de mérito analítico. Estudos relativos à natureza do fluxo foram conduzidos avaliando-se o desempenho dos fluxos pulsados provenientes de bombas solenóide em relação à eficiência do transporte de massas, dispersão da zona de amostra relacionada com a mudança de sentido do fluxo e eficiência do processo de diálise quando comparados aos fluxos tipicamente laminares. Embora fosse observada a presença de vórtices, o número de Reynolds experimentalmente obtido demonstrou que o fluxo resultante não era turbulento. Porém seu perfil exibia características de mescla turbulenta, melhorando assim o desempenho relativo ao transporte de massas e redução da dispersão da zona de amostra. Entretanto, beneficios relativos a melhorias no processo de diálise foram ausentes devido provavelmente à alta pressão exercida dentre da câmara de diálise, com consequente deformação dos poros da membrana. Nestas situações, um sistema de análises híbrido (com fluxo laminar e mescla turbulenta) seria fortemente recomendado. Finalmente, a implementação de nanocristais quantum dots (QDs) como sensibilizadores em um sistema MPFS envolvendo reação quimioluminescente foi proposta para a determinação de glipizida e gliclazida em formulaçoes farmacêuticas. O método fundamentava-se na oxidação dos íons S2- por Ce4+ em meio ácido. Na presença dos analitos, a intensidade da radiação emitida era inibida. A influência do diâmetro médio dos nanocristais foi avaliada, e os critérios utilizados para o dimensionamento do sistema foram a repetibilidade, a reprodutibilidade e a sensibilidade analítica. Os analitos foram quantificados no mesmo módulo de análises, e boas figuras de mérito analítico foram verificadas. Os resultados obtidos se apresentaram concordantes com aqueles obtidos pela Farmacopéia Britânica / Studies focusing on performance of intelligent analytical flow systems, association with multivariate calibration or use of nanocrystals as sensitizers were carried out. Moreover, improvements related to modifications in flow pattern were evaluated with emphasis to in-line dialysis. To this end, a strategy for implementing simultaneous determinations of iron and vanadium in alloys relying on differential kinetics was proposed. The method was based on the influence of Fe2+ and V4+ on the rate of iodide oxidation by Cr6+ under acidic conditions. Three different plugs of the sample were sequentially inserted into an acidic KI reagent carrier stream, and a confluent K2Cr2O7 solution was added downstream. Overlap between the established plugs led to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions were more precise and revealed the different degrees of reaction development. In another strategy, an intelligent MPFS was proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods were implemented in the same manifold, providing facilities for: in-line sample cleanup; addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation conditions and real-time decision on the need for next assay. The sample was initially run for chloride determination, and the analytical signal was compared with a preset value. If higher, the sample was run again, now for sulphate determination. Otherwise, next sample was assayed. The strategy led to an increased sample throughput and good analytical figures of merit. Studies focusing on the flow pattern were carried out aiming at the evaluation of the influence of the pulsed flows delivered by solenoid pumps in relation to the efficiency of mass transfer, dispersion related to changes in flow direction of the sample zone and dialysis process as compared with typical laminar flow. Although the establishment of vortices were noted, the experimentally obtained Reynolds number showed that a turbulent flow was not established. Its pattern exhibited characteristics which improved the performance due to the enhanced radial mass transport inherent in turbulent mixing. Comparatively to laminar flow, beneficial aspects were noted in relation to sample dispersion and mass transfer. In relation to dialysis efficiency however process the benefits were not noted probably due to the high pressure inside the dialysis chamber, with consequent membrane pore deformation. In this situation, a hybrid flow analysis system (with laminar flow and turbulent mixing) might be recommended. Implementation of quantum dots nanocrystals (QDs NC) as sensitizers in a MPFS with chemiluminometric detection was proposed for the determinations of gliclazide and glipizide in pharmaceutical formulations. The method relied on the oxidation of sulphite by Ce4+ in acidic medium and, in the presence of the analytes, the emitted radiation of the Ce4+-SO3 2--CdTe QDs system was inhibited. Influence of crystal size was investigated, and the criteria for system optimization were the analytical repeatability, reproducibility and sensitivity. Both analytes were quantified in the same manifold, resulting in good analytical figures of merit. The results were in fairly good agreement with those obtained by the British Pharmacopoeia reference method
124

A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluids

Guarilha Junior, Orlando 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.
125

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Batista, Alex Domingues 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
126

Preconcentration And Speciation Of Iron By Using Renewable Surface Flow Injection System (rs-fia)

Tekin, Serap 01 January 2004 (has links) (PDF)
The main aim of this study is to combine the sol-gel technology and renewable surface flow injection analysis (RS-FIA) techniques for iron speciation and determination. Thus the home-made FIA system, which consists of 2 syringe pumps and 3 multi-position selection valves, is modified with two flow cells (magnetic cell and jet ring cell) in order to be suitable for renewable surface flow injection technique. All the computer programs used for flow injection analysis are modified to control the whole system automatically. Two different types of solid phase extraction materials are used for the speciation of iron in aqueous systems. Magnetic beads coated with primary amino groups are utilized for the determination of Fe (III). The magnetic bead reactor is created within the flowing stream by retaining the magnetic beads with a home-made electromagnet. The elution cycle for Fe (III) is done with 0.1 M EDTA solution and determined on-line by transferring to an atomic absorption spectrometer. The spent beads are collected off-line and regenerated. For the preconcentration of Fe (II), ferrozine doped sol-gel beads are prepared as reactive and disposable surfaces. These beads are handled by the system equipped with a jet ring cell which is connected on-line to a portable UV-VIS fiber optic spectrometer. Amino sol-gel and ferrozine-doped sol-gel beads are prepared using sol-gel technology and characterized by using surface techniques. Their performances in preconcentration and speciation of iron and the influence of different experimental parameters such as pH, the sequence of reagents, reactor lengths and reaction periods on the flow system are investigated. Renewable surface flow injection analysis is performed by either bead injection or sequential bead injection methods.
127

Avaliação e síntese de corantes fenotiazínicos para determinação espectrofotométrica de sulfeto e sulfito empregando sistemas de análise em fluxo.

Santos, Josué Carinhanha Caldas January 2004 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-23T12:23:58Z No. of bitstreams: 2 Josue Santos Parte 2.pdf: 931346 bytes, checksum: b1e5922db0717587a7942e5c09cc5b01 (MD5) Josue Santos Parte 1.pdf: 1888156 bytes, checksum: 5a369c2be9a8867bc37dbf7937760f92 (MD5) / Made available in DSpace on 2013-04-23T12:23:58Z (GMT). No. of bitstreams: 2 Josue Santos Parte 2.pdf: 931346 bytes, checksum: b1e5922db0717587a7942e5c09cc5b01 (MD5) Josue Santos Parte 1.pdf: 1888156 bytes, checksum: 5a369c2be9a8867bc37dbf7937760f92 (MD5) Previous issue date: 2004 / Neste trabalho foram avaliadas sete aminas aromáticas O e N-substituídas em condições reacionais otimizadas para a síntese de corantes fenotiazínicos (CFs) simétricos. Entre estas, o N,N-dimetil -p- fenilenodiamino (DMPD), N,N- dietil -p- fenilenodiamino (DEPD), p-fenilenodiamino (PPD), p-aminofenol (PAP) e o p-aminoanisol (PAA) , levando a rendimentos entre 10 e 43%, para diferentes oxidantes (Fe3+ ou ClO-), ácidos (H2SO4 ou HBF4) e contra-íons (ClO4 - ou BF4 -). O DMPD apresentou as menores variaçõesnos rendimentos calculados para as diferentes condições reacionais investigadas. A partir dos resultados obtidos com a síntese dos CFs foi avaliada de forma comparativa a potencialidade do DMPD, DEPD, PPD, PAP e do PAA para determinação espectrofotométrica de sulfeto em sistema de análise em fluxo. Preliminarmente, foram comparados os sinais analíticos gerados pelo espectrofotômetro, em sistema em fluxo, para os corantes fenotiazínicos produzidos a partir das cinco aminas, avaliadas nas mesmas condições. Por apresentarem uma melhor cinética de formação dos respectivos CFs, as aminas DMPD, DEPD e PPD foram selecionadas para investigações mais detalhadas. Os estudos foram realizados empregando planejamento fatorial composto central, visando à otimização das condições em sistema de análise em fluxo. Os parâmetros avaliados foram as concentrações da amina aromática, do oxidante (Fe3+) e do H2SO4 na solução da amina. Nas faixas de concentração avaliadas para as 3 variáveis, somente o DMPD pôde ser otimizado, apresentando, também, robustez para pequenas variações nas concentrações dos parâmetros investigados. Mesmo em condições não otimizadas, o DEPD (LD, 18,34 mg L-1) produziu o corante fenotiazínico com maior absortividade molar. Nas melhores condições para a determinação de sulfeto o PPD e o DMPD apresentaram limite de detecção de 60,1 mg L-1 e 71,46 mg L-1, respectivamente. Adicionalmente, foi investigado um procedimento de análise em fluxo para determinação indireta de sulfito. Este era levado a SO2 e reduzido em linha a H2S na presença de ácido e Znº com uma taxa de conversão estimada em 10,31%. Desta forma, foi desenvolvida uma unidade integradora de operações (UIO), na qual a amostra era preparada (HSO3 - Æ SO2), convertida a H2S, o qual permeava através de membrana de PTFE e reagia com a mistura DMPD e Fe3+ para formar azul de metileno. A membrana de PTFE foi seletiva a H2S frente ao SO2, em diferentes condições. Visando pré-concentrar o H2S produzido na conversão de sulfito, foi desenvolvido um circuito eletrônico para controlar as válvulas solenóides, visando a interrupção do fluxo da solução receptora. As variáveis do sistema foram otimizadas e a recepção em solução de NaOH mostrou-se mais sensível que em DMPD e Fe3+. A utilização de solução transportadora com álcool etílico 15% (v/v) nivelou o efeito do álcool presente nas soluções da amostras de vinho. Para o procedimento em fluxo proposto, o H2S foi interferente para concentrações > 0,5 mg L-1 em condições normais e > 10 mg L-1 se a amostra for tratada previamente com solução de acetato de zinco. O procedimento analítico em fluxo apresentou faixas de trabalho distintas para sulfito livre e total, apresentando limites de detecção (3s) inferiores a 0,35 e 1,2 mg L-1, respectivamente.A potencialidade do processo foi avaliada para a determinação dos teores de sulfito em amostras de sucos e vinhos. Os resultados obtidos foram comparados com aqueles obtidos empregando procedimento de referência e apresentaram boa concordância com 95% de confiança. / Salvador
128

A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluids

Orlando Guarilha Junior 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.
129

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Alex Domingues Batista 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
130

Construção, caracterização e aplicação analítica de microdispositivos enzimáticos

Cerqueira, Marcos Rodrigues Facchini 09 September 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-21T18:21:21Z No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-22T12:39:49Z (GMT) No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) / Made available in DSpace on 2017-03-22T12:39:49Z (GMT). No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) Previous issue date: 2016-09-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O foco deste trabalho foi o desenvolvimento e aplicação de microreatores enzimáticos, visando sua aplicação em sistemas de análise por injeção em fluxo. Em cima disso, dois substratos poliméricos foram utilizados para a avaliação de imobilização enzimática: um à base de poli (metil metacrilato) (PMMA) e outro em uma resina do éter diglicídico do bisfenol-A (BADGE). Uma impressora à laser de CO2 foi utilizada para confeccionar os dispositivos nas dimensões desejadas. Para o sucesso da imobilização, os sistemas foram previamente tratados com polietilenoimina (PEI) visando a introdução de grupamentos funcionais reativos na superfície dos materiais de partida. Num primeiro estudo, baseado na modificação de PMMA, a ativação do material foi conseguida após tratamento dos microcanais com PEI em meio de dimetilsulfóxido (DMSO). Já no segundo caso o tratamento com PEI envolveu a simples mistura mecânica dos materiais, objetivando a cura da resina empregada. Após a ativação dos materiais com PEI, as enzimas foram imobilizadas após passagem de uma mistura de glutaraldeído (um agente espaçador) e as enzimas. Dentre as enzimas estudadas estão a glicose oxidase (GOx), a ascorbato-oxidase (AAO), a catalase (CAT), a glutamato dehidrogenase (GDH), além de um sistema híbrido baseado na imobilização simultânea das enzimas glicose oxidase (GOx) e horseradish peroxidase (HPR). A caracterização dos sistemas desenvolvidos foi feita primordialmente por meio da espectroscopia Raman. Além disso, a aplicação de alguns dos sistemas frente a amostras reais e o cálculo de parâmetros cinéticos e operacionais dos microreatores confeccionados foram reralizados. Essas avaliações foram feitas baseadas em sistemas de detecção desenvolvidos no laboratório por técnicas eletroquímicas e por espectroscopia no visível. Como grande benefício dos sistemas desenvolvidos, podem ser destacados a velocidade e a simplicidade de implementação do processo de imobilização e operação. / The focus of this work is the development and application of enzymatic microreactors aiming their application through flow injection analysis systems. On top of that, two polymeric substrates were used for the evaluation of enzyme immobilization: one based on poly (methyl methacrylate) (PMMA) and another baed on a bisphenol-A diglycidyl ether resin (BADGE). A CO2 laser printer was used to fabricate the devices at the desired dimensions. For the success of the immobilization systems have been pretreated with polyethyleneimine (PEI) in order to introduce reactive functional groups on the surface of the starting materials. In a first study, based on PMMA modification, the activation of the material was achieved after treating microchannels with PEI in dimethylsulfoxide (DMSO). In the second case, treatment with PEI involved simply a mechanical mixture of the two materials, in order to cure the resin. After activation of materials with PEI, the enzymes were immobilized after passage of a mixture of glutaraldehyde (a spacer agent) and enzymes. Among the enzymes studied are glucose oxidase (GOx), ascorbate oxidase (AAO), catalase (CAT), dehydrogenase glutamate (GDH), and a hybrid system based on the simultaneous immobilization of the enzymes glucose oxidase (GOx) and horseradish peroxidase (HPR). The characterization of the developed systems was primarily done by Raman spectroscopy. Moreover, application of some of the proposed systems to real samples and calculation of kinetic and operational parameters are presented during the study. These evaluations were made with detection systems based on electrochemical and visible spectroscopy techniques, all developed at the laboratory. One great benefit of the developed systems, are the speed and simplicity of implementation the immobilization process and operation of the devices.

Page generated in 0.098 seconds