• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 18
  • 16
  • 12
  • 10
  • 9
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Miljöpåverkan vid grundläggning i samband med vägbyggnad : En komparativ fallstudie av inblandningspelare, lättklinker, skumglas och cellplast (EPS) ur ett hållbart och ekonomiskt perspektiv / Environmental impacts of foundation methods in connection to road construction : A comparative case study of deep soil mixing, expanded clay lightweight aggregate, foam glass and expanded polystyrene foam (EPS) from an environmental and economical perspective

Brännmark, Disa, Cano Norberg, Desirée January 2019 (has links)
Jordens klimat varierar normalt över tid, men aldrig tidigare har klimatförändringarna varit så snabba och påtagliga. Stigande temperaturer, förhöjda havsnivåer och hotade ekosystem är till stor del en följd av människans miljöpåverkan som genom sitt utnyttjande av resurser och utsläpp bidrar till den utökade växthuseffekten. Alla berörs och samtliga måste ta sitt ansvar för att förhindra att detta fortskrider. Genom att förstå miljökonsekvenserna av sitt agerande kan bättre förutsättningar skapas för kommande generationer. Studier visar att byggbranschen står för nästan en tredjedel av de totala utsläppen av växthusgaser, men att det fortfarande finns kunskapsluckor kring var miljöpåverkan är som störst. Genom klimatavtal, branschöverskridande forum och verktyg i form av livscykelanalyser och miljövarudeklarationer kan kunskapen lyftas. Ett flertal lättillgängliga verktyg med generiska data har utvecklats för livscykelanalyser av byggnader, men för anläggningssektorn finns ännu inte helt anpassade verktyg. I nuläget väljs grundläggningsmetod mestadels utifrån den ekonomiska aspekten, vilket bidrar till att miljöaspekten inte får önskvärt utrymme. Denna studie är en fallstudie som söker svar på vilken grundläggningsmetod som lämpar sig bäst ur ett hållbart och ekonomiskt perspektiv i en specifik jordprofil av lera som är vanligt förekommande kring Uppsala. För att lyfta kunskapen kring miljöpåverkan, jämfördes fyra vanliga grundläggnings-metoder: inblandningspelare med Multicem och lättfyllnadsmetoderna; lättklinker, skumglas och cellplast. Utifrån sättningsberäkningar i jordprofilen kunde dimensioneringar utföras av materialåtgång för respektive metod. Dimensioneringen användes sedan för att utföra kostnadsuppskattningar och beräkningar av klimatpåverkan, i form av koldioxidekvivalenter, under produktframställning och transporter till den specifika platsen. Utöver detta undersöktes bedömningen av det kemiska innehållet genom två miljödatabaser, BASTA och SundaHus. Resultatet visade att skumglas har den lägsta totala klimatpåverkan, där ungefär hälften av koldioxid¬utsläppen kommer från produktionen och resterande del från transporter. Det tyder på att det geografiska läget för grundläggningen spelar en väsentlig roll för resultatet av klimatpåverkan. Skumglas erhåller bästa betyg i BASTA och SundaHus men har den högsta totalkostnaden av de jämförda alternativen i studien. Inblandningspelare med Multicem som bindemedel har den lägsta totalkostnaden och den näst lägsta klimatpåverkan. Genom intervjustudien konstaterades att val av grundläggningsmetod främst avgörs av kostnaden vilket innebär att Multicem förmodligen skulle väljas i första hand. Utifrån kemiskt innehåll är bedömningen däremot ofullständig, eftersom Multicem ännu inte finns deklarerad i SundaHus. Sammanfattningsvis beror valet av grundläggningsmetod på ett flertal faktorer där företag måste värdera vilken faktor som har högst prioritet. / The climate normally varies over time but never before has the climate change been so rapid and tangible. Rising temperatures, elevated sea levels and endangered ecosystems are consequences of human impact on the environment. The use of resources and emissions contributes to the increased impact on the greenhouse effect. Everyone is affected by the climate change and must take his or her responsibility to create better conditions for future generations by understanding the environmental consequences of his or her actions. Studies reveal that the construction industry accounts for almost one third of the total greenhouse gas emissions but there are still gaps in knowledge about the environ¬mental impact. The knowledge can increase through agreements on climate actions, industry-wide forums and tools such as life-cycle assessments and environmental product declarations. Several available tools with generic data have been developed for life-cycle assessments of buildings, but for the infrastructure sector the tools are still not fully developed. Today, the foundation method is mostly chosen based on the economical aspect, and the environmental aspect is not given priority. The aim of this case study is to investigate which foundation method is best suited from an environ-mentally sustainable and economical perspective in a specific soil profile of clay which is common around Uppsala. To raise awareness of environmental impact, four common foundation methods were compared: deep soil mixing with Multicem and light filling methods; expanded clay lightweight aggregate, foam glass and expanded polystyrene foam. Based on settlement calculations in the soil profile, dimensions could be made for consumption of material for each method. The consumption of material was used to make estimations of costs and calculations of climate effect, in terms of carbon dioxide equivalents, during production of the material and transport to the specific location. In addition, the assessment of the chemical content was examined through two environmental databases, BASTA and SundaHus. The result revealed that foam glass has the lowest total climate effect, where about half of the carbon dioxide emissions come from production and the remainder from transport. This indicates that the geographical location of the foundation is important for the result of the climate impact. Foam glass receives the best ratings in BASTA and SundaHus but has the highest total cost of the compared alternatives in the study. Deep soil mixing with Multicem as binder has the lowest total cost and the second lowest climate impact. Through the interview study, it was found that the choice of foundation method is mainly determined by the cost, which means that Multicem would probably be prefered. Based on chemical content the assessment is incomplete since Multicem has not been declared in SundaHus. In summary, the choice of foundation method depends on a number of factors in which companies must evaluate which factor has the highest priority.
32

Fuktkontroll av en ventilerad platta på mark : Modellering i COMSOL Multiphysics 5.5

Liljestrand, Simon, Lundell, Viktor January 2020 (has links)
Krypgrunder i någon form har använts som grundkonstruktion i Sverige under långtid. Förr var det torpargrunder som med tiden blev isolerade krypgrunder och plintgrunder. Gemensamt för krypgrundskonstruktioner som är ventilerade med utomhusluft är att under sommarhalvåret blir det förhöjda relativa ånghalter. Syftet med fallstudien är att studera en uteluftsventilerad konstruktion med välisolerat bjälklag och markisolering. Konstruktionen är nedgrävd och ventilationen i grunden sker via en tunn spalt under marknivå. Luftspaltens temperatur och relativa ånghalt är av intresse för att avgöra om det finns risken för mögel i konstruktionen. En simulering av värmeflödet mellan byggnad och mark genomförs i COMSOLMultiphysics 5.5 för att avgöra temperaturfördelningen i konstruktionen. Temperaturfördelningen ligger som grund för fastställandet av relativ ånghalt i konstruktionens luftspalt. Simuleringen använder klimatdata för ett typår i Gävle. Simuleringen visar att det är höga temperaturer i luftspalten året runt. Detta ger enrelativ ånghalt som månadsmedel på 37–77% under ett år. Den höga temperaturen iluftspalten bidrar till att hålla konstruktionen torr då kritisk relativ ånghalt, 75–80%, inte överstigs under en längre period. Resultat är förvånansvärt positivt med en låg risk för mögeltillväxt i konstruktionen.Det finns många antaganden framförallt vilket luftflöde som återfinns i luftspalten.För att validera resultaten i arbetet så bör mätningar genomföras på de två prototyphus som existerar. / Crawl spaces in some form have been used as foundations in Sweden for a long time.In the past, it was uninsulated crawl spaces that eventually evolved into insulatedcrawl spaces and open plinth foundations. An increased relative humidity during thesummer is a common problem for crawl spaces that are ventilated with outdoor air. The purpose of the case study is to study an outdoor ventilated structure with wellinsulated floor and ground insulation. The construction is below ground level andthe ventilation takes place via a thin air gap below ground level. The temperatureand relative humidity in the air gap are of interest to determine if there is a risk ofmould growth in the design. A simulation of the heat flow between the building and the ground is carried out inCOMSOL Multiphysics 5.5 to determine the temperature distribution in the design.The temperature distribution is the basis for the determination of relative vaporcontent in the air gap of the structure.The simulation uses climate data for a typicalyear in Gävle. The simulation shows a high temperature in the air gap which gives a relative vaporcontent as a monthly average of 37–77% during a year. The high temperature in theair gap contributes to keeping the structure dry when critical relative humidity, 75–80%, is not exceeded for a longer period of time. The results are surprisingly positive with a low risk of mold growth in the construction.There are many assumptions, in particular, which airflow is found in the airgap. In order to validate the results in the work, measurements should be made onthe two prototype houses that exist.

Page generated in 0.0515 seconds