• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 83
  • 7
  • 1
  • Tagged with
  • 92
  • 92
  • 79
  • 77
  • 43
  • 38
  • 35
  • 29
  • 23
  • 22
  • 20
  • 19
  • 19
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Supressão das emissões otoacústicas evocadas por estímulo \"tone burst\" em neonatos com risco para perda auditiva / Otoacoustic emissions suppression with tone burst in neonates at risk for hearing loss

Jordana Costa Soares 23 June 2008 (has links)
INTRODUÇÃO: Uma possibilidade de pesquisa em audição é a supressão das emissões otoacústicas, que verifica a diminuição de sua magnitude a partir de estimulação acústica simultânea. Acredita-se que esta diminuição ocorra devido ao papel da via eferente auditiva. OBJETIVO: verificar a atividade do sistema auditivo eferente, por meio da supressão contralateral das emissões otoacústicas, em neonatos com e sem indicadores de risco para perda auditiva. MÉTODO: foram avaliados 21 neonatos com indicadores de risco para perda auditiva (grupo estudo) e 30 neonatos sem indicadores (grupo controle) por meio das emissões otoacústicas evocadas por estímulo de freqüência específica \"tone burst\" em 2000 e em 4000 hertz, na ausência e na presença de ruído branco contralateral. RESULTADOS: a orelha direita e o grupo controle apresentaram vantagem na amplitude das EOA TB. Os valores médios de \"Response\" para 2000 hertz foram 17,73 dB no grupo controle e 16,55 dB no grupo estudo, para o gênero feminino e 16,63 dB no grupo controle e 16,12 dB no grupo estudo, para o gênero masculino. Para 4000 hertz, os valores médios de \"Response\" foram 14,63 dB no grupo controle e 15,09 dB no grupo estudo, para o gênero feminino e 18,57 dB no grupo controle e 15,06 dB no grupo estudo, para o gênero masculino. Na supressão, houve vantagem da orelha direita, do grupo controle para o gênero feminino e do grupo estudo para o gênero masculino, embora sem plena significância estatística. Os valores médios de supressão para a variável \"Response\" em 2000 hertz foram 1,66 dB no grupo controle e 0,84 dB no grupo estudo, para o gênero feminino e 1,41 dB no grupo controle e 2,07 dB no grupo estudo, para o gênero masculino. Para 4000 hertz, os valores médios da supressão em \"Response\" foram 1,29 dB no grupo controle e 0,98 dB no grupo estudo, para o gênero feminino e 1,75 dB no grupo controle e 2,14 dB no grupo estudo, para o gênero masculino. CONCLUSÃO: A partir de estímulos de freqüência específica, em 2000 e em 4000 hertz, foi possível verificar o efeito inibitório da via eferente auditiva sobre a amplitude das EOA, em neonatos. A utilização de estímulos de freqüência específica pode contribuir para a avaliação da função auditiva periférica e central nesta população. / INTRODUCTION: A possible hearing research is the suppression of otoacoustic emissions which verifies a decrease of its magnitude from a simultaneous acoustic stimulation. It is assumed that this decrease occurs because of the role of the auditory efferent pathway. AIM: to verify the activity of the auditory efferent pathway by the contralateral suppression of OAE in neonates with and without risk factors for hearing loss. MEHOD: 21 neonates at risk for hearing loss (study group), and 30 neonates without risk factors for hearing loss (control group) were assessed through otoacoustic emissions evoked by a frequency specific stimulus, \"tone burst\", at 2000 and at 4000 hertz, with and without contralateral white noise. RESULTS: the right ear and the control group presented advantage in the amplitude of OAE TB. The mean values of \"Response\" at 2000 hertz were 17,73 dB in the control group and 16,55 dB in the study group, for female subjects, and 16,63 dB in the control group and 16,12 dB in the study group, for male subjects. At 4000 hertz, the mean values of \"Response\" were 14,63 dB in the control group and 15,09 dB in the study group, for female subjects and 18,57 dB in the control group and 15,06 dB in the study group, for male subjects. In the suppression, there was an advantage of the right ear, of the control group for female subjects, and of the study group for male subjects, although without statistical significance. The mean values of suppression for the variable \"Response\" at 2000 hertz were 1,66 dB in the control group and 0,84 dB in the study group, for female subjects, and 1,41 dB in the control group and 2,07 dB in the study group, for male subjects. At 4000 hertz, the mean values of suppression for \"Response\" were 1,29 dB in the control group and 0,98 dB in the study group, for female subjects, and 1,75 dB in the control group and 2,14 dB in the study group, for male subjects. CONCLUSION: From frequency-specific stimuli at 2000 and at 4000 hertz, it was possible to verify the inhibitory effect of the auditory efferent pathway upon the amplitude of otoacoustic emissions in neonates. The use of frequencyspecific stimuli may contribute for the assessment of the central auditory function in this population.
72

Treinamento auditivo: avaliação do benefício em idosos usuários de próteses auditivas / Auditory training: evaluation of the benefits for elderly hearing aids users

Renata Luciane Megale 07 August 2006 (has links)
INTRODUÇÃO: A deficiência auditiva acarreta dificuldades na comunicação, as quais podem ser minimizadas através da adaptação de próteses auditivas e do treinamento auditivo. OBJETIVO: o objetivo geral deste estudo foi verificar a efetividade do treinamento auditivo em idosos novos usuários de próteses auditivas, quanto ao benefício no processo de adaptação. MÉTODOS: Foram selecionados 42 indivíduos portadores de deficiência auditiva neurossensorial de grau leve a moderado, com idades entre 60 e 90 anos, novos usuários de próteses auditivas bilaterais, distribuídos em dois grupos: Grupo Experimental (GE) e Grupo Controle (GC). O GE foi submetido a um programa de treinamento auditivo em cabina acústica durante seis sessões. Ambos os grupos foram avaliados com os testes de Fala com Ruído, Escuta com Dígitos, e questionários de auto-avaliação HHIE e APHAB, em três momentos: sem próteses (1ª avaliação), quatro semanas (2ª avaliação), e oito semanas (3ª avaliação), após a adaptação das próteses. RESULTADOS: houve diferença estatisticamente significante para os dois testes aplicados, e para o questionário APHAB (quanto ao benefício) na 2ª e na 3ª avaliações, nas sub-escalas: Facilidade de Comunicação, Reverberação e Ruído Ambiental, o que não ocorreu para o questionário HHIE. CONCLUSÕES: o programa de treinamento auditivo em cabina acústica foi efetivo com relação ao benefício durante o processo de adaptação das próteses auditivas. / INTRODUCTION: Hearing loss causes communication difficulties that can be minimized through the adaptation of hearing aids and through the auditory training. AIM: the purpose of this study was to verify the effectiveness of the auditory training for elderly hearing aids recent users concerning the benefits for the adaptation process. METHOD: 42 individuals with mild to moderate sensorineural hearing loss, ranging in age from 60 to 90 years, recent bilateral hearing aids users were selected and divided into two groups: Experimental Group (EG) and Control Group (CG). The EG underwent an auditory training program in an acoustic booth during six sessions. Both groups were evaluated with Speech in Noise Test, Dichotic Digits Test and the questionnaires HHIE and APHAB in three moments: without the hearing aid (1st evaluation), four weeks (2nd evaluation) and 8 weeks (3rd evaluation) after the hearing aids adaptation. RESULTS: there was a significant statistical difference for the two tests used and for the APHAB questionnaire (concerning the benefit) in the 2nd and 3rd evaluations, in the sub-scales: Communication Facility, Reverberation and Environmental Noise, not verified in the HHIE questionnaire. CONCLUSIONS: the auditory training program in acoustic booth was effective concerning the benefit during the hearing aids adaptation process.
73

Via de nascimento e resultado da triagem auditiva neonatal / Route of birth and result of newborn hearing screening / Ruta de nacimiento y resultado de screening auditivo neonatal

Weiss, Kátia Maria January 2014 (has links)
Estudo quantitativo prospectivo transversal analítico realizado entre janeiro e abril de 2014 em um hospital universitário de Porto Alegre, com o objetivo de verificar a influência da via de nascimento no resultado da triagem auditiva neonatal. A população foi composta por 543 neonatos cujos critérios de inclusão foram: terem nascido de via vaginal ou via cesárea, permanecerem internados em alojamento conjunto, com idade gestacional igual ou superior a 37 semanas, sem indicadores de risco para a deficiência auditiva, com peso ao nascimento igual ou superior a 2500 gramas e estarem com 24 horas ou mais de vida no momento da avaliação. Foram realizadas duas tentativas para obter respostas na triagem auditiva neonatal utilizando o procedimento de emissões otoacústicas evocadas transientes. Entre as duas tentativas foi utilizada a manobra facilitadora quando a resposta não era observada na primeira tentativa. Dos 543 neonatos, 70,3% (n = 382) nasceram de por vaginal e 29,7% (n = 161) de por cesárea. Os resultados mostraram que quando comparadas as características dos neonatos conforme a via de nascimento, o grupo de neonatos nascidos por via cesárea apresentou maior prevalência de sexo masculino (p=0,020), recém-nascidos com menor Apgar no primeiro e no quinto minuto (p=0,011 e p=0,005, respectivamente). Entretanto os neonatos que necessitaram de uma segunda tentativa para se observar presença de respostas das emissões otoacústicas, o grupo de cesárea teve mais necessidade de manobra em ambas as orelhas e no grupo de via vaginal foi necessário mais manobra mais a orelha esquerda (p=0,027). Quando ajustado por possíveis fatores de confusão (sexo, peso, número de horas de vida, via de nascimento, idade materna, número de consultas pré-natal e idade gestacional), a via cesárea permanece um fator significativamente associado à necessidade de manobra facilitadora em ambas as orelhas. Recém-nascidos de cesárea têm 2,83 vezes mais a prevalência de manobra em ambas as orelhas, quando comparados aos RN de via vaginal (RP=2,83; IC 95%: 1,20 – 6,68; p=0,017). Conclui-se que, quando ajustado por possíveis fatores de confusão, a via de nascimento pode influenciar nas respostas da triagem auditiva. Assim, esse é um tema que necessita de mais estudos que levem à compreensão dos fatores presentes durante o nascimento que possam interferir nos resultados da triagem auditiva neonatal. Acredita-se que estudos semelhantes com metodologia diferente possam elucidar e corroborar com estes achados. / A cross-sectional prospective quantitative study carried out between January and April 2014 in a university hospital in Porto Alegre, in order to check the influence of the route of birth results in neonatal hearing screening. The population consisted of 543 neonates whose inclusion criteria were: being born vaginally or via cesarean section, remain hospitalized in rooming with gestational age less than 37 weeks without risk indicators for hearing loss, with weight birth equal to or greater than 2500 grams and be 24 hours or more of life at the time of evaluation. Two attempts were made to obtain responses in neonatal hearing screening using the procedure of transient evoked otoacoustic emissions. Between the two attempts at facilitating maneuver when the response was not observed in the first trial was used. Of the 543 neonates, 70.3% (n = 382) were born vaginally and 29.7% (n = 161) by cesarean section. The results showed that compared the characteristics of newborns as a means of birth, the group of neonates born by cesarean section showed a higher prevalence of male gender (p = 0.020), infants with lower Apgar scores at one and five minutes (p = 0.011 and p = 0.005, respectively). However neonates who required a second attempt to observe the presence of OAE responses, the cesarean group had more need to maneuver in both ears and the group of vaginally more maneuver was necessary over the left ear (p = 0.027 ). When we adjusted for potential confounders (sex, weight, number of hours of life, route of birth, maternal age, number of prenatal visits and gestational age), cesarean section remains a factor significantly associated with the need for facilitating maneuver both ears. Newborn cesarean have 2.83 times the prevalence of maneuver in both ears, when compared with infants of vaginally (PR = 2.83, 95% CI: 1.20 to 6.68, p = 0.017) . We conclude that, when adjusted for possible confounding factors, the route of birth may influence the responses of auditory screening. So, this is a topic that needs further study leading to the understanding of factors present at birth that may affect the outcome of neonatal hearing screening. It is believed that similar studies with different methodology elucidate and corroborate these findings. / Un estudio cuantitativo prospectivo transversal realizado entre enero y abril de 2014 en un hospital universitario de Porto Alegre, con el fin de comprobar la influencia de la ruta de los resultados de nacimiento en tamizaje auditivo neonatal. La población estuvo constituida por 543 neonatos cuyos criterios de inclusión fueron: haber nacido por vía vaginal o por cesárea, permanece hospitalizado en alojamiento conjunto con la edad gestacional menor de 37 semanas sin indicadores de riesgo para la pérdida de audición, con el peso nacimiento igual o mayor que 2500 gramos y ser de 24 horas o más de vida en el momento de la evaluación. Se hicieron dos intentos para obtener respuestas en el cribado auditivo neonatal utilizando el procedimiento de evocadas transitorias emisiones otoacústicas. Entre los dos intentos de facilitar la maniobra cuando no se observó la respuesta en el primer ensayo se utilizó. De los 543 recién nacidos, el 70,3% (n = 382) nacieron por vía vaginal y el 29,7% (n = 161) por cesárea. Los resultados mostraron que, en comparación de las características de los recién nacidos como un medio de nacimiento, el grupo de neonatos nacidos por cesárea mostraron una mayor prevalencia de sexo masculino (p = 0,020), los niños con menores puntuaciones de Apgar al minuto y cinco minutos (p = 0,011 y p = 0,005, respectivamente). Sin embargo los recién nacidos que requirieron un segundo intento de observar la presencia de respuestas OAE, el grupo de cesárea tenían más necesidad de maniobrar en ambas orejas y el grupo de la vagina más maniobra fue necesaria sobre la oreja izquierda (p = 0,027 ). Cuando ajustamos por posibles factores de confusión (sexo, peso, número de horas de duración, ruta de nacimiento, edad materna, número de visitas prenatales y la edad gestacional), la cesárea sigue siendo un factor asociado significativamente con la necesidad de facilitar la maniobra ambos oídos. Cesárea recién nacido tiene 2,83 veces la prevalencia de maniobra en ambos oídos, en comparación con los bebés de la vagina (RP = 2,83, IC del 95%: 1,20 a 6,68, p = 0,017) . Llegamos a la conclusión de que, al ajustar por posibles factores de confusión, la vía de nacimiento puede influir en las respuestas de screening auditivo. Por lo tanto, este es un tema que requiere mayor estudio que lleva a la comprensión de los factores presentes en el nacimiento que pueden afectar el resultado del cribado auditivo neonatal. Se cree que los estudios similares con diferente metodología de dilucidar y corroborar estos hallazgos.
74

Complexo N1-P2-N2 em indivíduos com transtorno de processamento auditivo submetidos ao treinamento auditivo / N1-P2-N2 complex in indivíduals with auditory processing disorder submitted to auditory training

Tatiane Eisencraft 30 October 2007 (has links)
INTRODUÇÃO: O uso de testes eletrofisiológicos associados a avaliação comportamental, vem se tornando uma prática clínica cada vez mais freqüente no campo da audiologia, possibilitando um diagnóstico e monitoramento do Transtorno de Processamento Auditivo mais preciso. OBJETIVOS: O objetivo geral deste estudo foi verificar as características (latência e amplitude) do complexo N1-P2-N2 em crianças com Transtorno de Processamento Auditivo, além de verificar a evolução dessas características após o Treinamento Auditivo. MÉTODOS: Foram selecionados 30 indivíduos com Transtorno de Processamento Auditivo e 22 indivíduos sem Transtorno de Processamento Auditivo, com idades entre oito e 16 anos que constituíram respectivamente o Grupo Estudo (GE) e o Grupo Controle (GC). Todos os indivíduos do nosso estudo passaram por uma avaliação inicial do Processamento Auditivo e do Potencial Eletrofisiológico de Longa Latência o complexo N1-P2-N2 (1ª avaliação). O GE foi submetido a um programa de treinamento auditivo em cabina acústica durante oito sessões e posteriormente reavaliado tanto por testes comportamentais quanto pelo teste eletrofisiológico (2ª avaliação). O GC, como não foi submetido a um programa de treinamento auditivo, foi reavaliado (2ª avaliação) após três meses da avaliação inicial. RESULTADOS: Para os testes comportamentais utilizados na Avaliação do Processamento Auditivo, houve diferença estatisticamente significante em todos os testes quando comparados o GE e o GC na 1ª avaliação e nas situações pré e pós o treinamento auditivo no GE. Quanto ao complexo N1-P2-N2 houve diferença estatisticamente significante para a latência da onda N1 e a amplitude da onda P2 na 1ª avaliação quando comparados o GE e o GC. Na situação pré e pós treinamento no GE, houve diferença estatisticamente significante para a latência da onda P2 e amplitude das ondas N1 e P2. No GC, quando comparadas na situação inicial e após três meses não houve diferença estatisticamente significante. CONCLUSÕES: As medidas eletrofisiológicas do Complexo N1-P2-N2 parecem ser um bom instrumento no auxilio do diagnóstico e monitoramento da terapia em crianças com Transtorno de Processamento Auditivo uma vez que essas crianças apresentaram diferenças nas medidas de latência e amplitude deste potencial após treinamento auditivo. / INTRODUCTION: The use of electrophysiological tests associated to behavioral evaluation has become a frequent practice in the audiology field enabling a more precise diagnosis and monitoring of the Auditory Processing Disorder. AIM: the aim of this study was to verify the N1-P2-N2 complex characteristics (latency and amplitude) in children with Auditory Processing Disorder, and also to verify the evolution of such characteristics after Auditory Training. MÉTHODS: 30 individuals with Auditory Processing Disorder and 22 individuals without Auditory Processing Disorder were selected, ranging in age from eight to 16 years old, composing respectively the Study Group (SG) and the Control Group (CG). All individuals underwent an initial evaluation of the Auditory Processing and of the N1-P2-N2 complex Long Latency Electrophysiological Potential (1st evaluation). The SG was submitted to an auditory training program in acoustic booth during 8 sessions and was reevaluated later by both behavioral and electrophysiological tests (2nd evaluation). The CG was not submitted to an auditory training program, and was reevaluated (2nd evaluation) three months after the initial evaluation. RESULTS: There was a significant statistical difference in all behavioral tests used in the Auditory Processing Evaluation when comparing the SG and the CG in the 1st evaluation, and in the situations pre and post auditory training in the SG. Concerning the N1-P2-N2 complex, there was a significant statistical difference for the latency of wave N1 and the amplitude of wave P2 in the 1st evaluation when comparing the SG and the CG. In the pre and post auditory training situations, there was a significant statistical difference for the latency of wave P2 and the amplitude of waves N1 and P2. In the CG there was no significant difference between the initial and the 2nd evaluation three months later. CONCLUSIONS: The electrophysiological measures of the N1-P2-N2 complex seem to be a good instrument for assisting the diagnosis and the therapy monitoring of children with Auditory Processing Disorder, once these children presented differences in the latency and amplitude measures of such potential after auditory training.
75

Variação no desempenho auditivo em crianças com transtorno fonológico e do processamento auditivo após programa de estimulação / Variation in auditory performance in children with phonological and auditory processing disorders after stimulation program

Nadia Vilela 19 August 2011 (has links)
INTRODUÇÃO: O treino auditivo tem sido uma importante ferramenta para estimular indivíduos com transtorno do processamento auditivo (central) (TPA(C)). Além disso, não é rara a presença de TPA(C) em crianças com transtorno fonológico. OBJETIVOS: Elaborar programa de estimulação auditiva, assim como comparar o desempenho em testes comportamentais do processamento auditivo (central) (PA(C)) em crianças com transtorno fonológico que passaram por treino auditivo formal e informal. MÉTODO: Foi desenvolvido programa de estimulação auditiva com objetivo de obter material controlado para o treino auditivo informal. Foram avaliados 15 indivíduos com transtorno fonológico (limiares tonais 20 dBNA nas freqüências de 0,50 a 4 kHz e idade entre 7:0 e 10:11 anos) por meio dos testes Identificação de Figuras com Ruído Competitivo Ipsilateral, Dicótico de Dígitos, Padrão Temporal de Freqüência e Padrão Temporal de Duração, formando três grupos: Grupo Controle (grupo C) composto por cinco sujeitos (com média de 9,1 anos) com alteração em apenas um teste comportamental do PA(C); Grupo Treino Auditivo Formal (grupo TAF) com cinco sujeitos (com média de 8,3 anos) com alteração em pelo menos dois testes do PA(C); e Grupo Treino Auditivo Informal (grupo TAI), com cinco sujeitos (com média de 8,1 anos), com alteração em pelo menos dois testes. Todos os participantes foram avaliados quanto ao grau de severidade do transtorno fonológico e realizaram duas avaliações do PA(C), com intervalo de seis a oito semanas, sem receber qualquer intervenção fonoaudiológica. Após a segunda avaliação do PA(C), as crianças do grupo TAF foram submetidas a oito sessões de treino auditivo formal e as crianças do grupo TAI receberam oito sessões de treino auditivo informal. Após o TAF e TAI, as crianças foram reavaliadas quanto ao PA(C). RESULTADOS: O grau de severidade do transtorno fonológico foi diferente entre o grupo Controle e os grupos TAF e TAI (p= 0,007). Após oito sessões de TAI houve melhora em todos os testes aplicados, exceto para o teste Dicótico de Dígitos na orelha direita. Entre a primeira e a terceira avaliação do PA(C), observou-se diferença estatística no grupo TAI para o teste Identificação de Figuras na orelha direita e esquerda (p=0,02). Houve melhora no desempenho auditivo pré e pós treino nos grupos TAF e TAI, embora sem diferença estatística. CONCLUSÃO: A gravidade do transtorno pareceu ter relação com a presença de TPA(C). A aplicação de oito sessões de TAI também foi capaz de provocar melhora no desempenho das crianças com TPA(C) e transtorno fonológico / BACKGROUND: The auditory training has been being an important tool to stimulate individuals with (Central) Auditory Processing Disorder ((C)APD). Moreover, the presence of (C)APD in children with phonological disorders is not uncommon. PURPOSE: The development of an auditory stimulation program, and the comparison of the performance in behavioral tests of (central) auditory processing ((C)AP) in children with phonological disorders who have undergone formal and informal auditory training. METHODS: A program of auditory stimulation was developed in order to obtain controlled material for informal auditory training. Fifteen subjects with phonological disorder ( 20 dB HL tone thresholds at frequencies from 0.50 to 4 kHz and age between 7:0 and 10:11 years) were evaluated through the Figure Identification test with ipsilateral competitive noise, Dichotic Digits test, Pitch Pattern Sequence and Duration Pattern Sequence test, forming three groups: The Control Group (C group) consisting of five subjects (average 9.1 years) with alteration in only one behavioral test of the (C)AP; the Formal Auditory Training Group (FT group) with five subjects (average 8.3 years) with alteration in at least two (C)AP tests; and the Informal Auditory Training Group (IT group), with five subjects (average 8.1 years) with alteration in at least two tests. All participants were assessed for degree of severity of phonological disorders and conducted two evaluations of the (C)PA at intervals of six to eight weeks without receiving any therapy. After the second evaluation of the (C)AP, the children of the FT group underwent eight formal auditory training sessions and the children of the IT group received eight sessions of informal auditory training. After the FT and IT, the children have been re-evaluated on the (C)AP. RESULTS: The severity of phonological disorder was different between the control group and the FT and IT groups (p=0,007). After eight sessions of IT there was an improvement in all tests, except for the Dichotic Digits test in the right ear. Between the first and the third evaluation of (C)AP, a statistical difference was observed in the IT group for the figure identification test in the right and left ears (p=0,02). Improvement occurred in auditory performance before and after training in the FT and IT groups, although no statistical difference was observed. CONCLUSION: The severity of the disorder seems to be related to the presence of (C)APD. The application of eight sessions of IT was also able to induce improvement in the performance of children with (C)AP and phonological disorders
76

Processamento auditivo (central) em crianças com  dislexia: avaliação comportamental e eletrofisiológica / Auditory Processing in children with dyslexia: behavioral and electrophysiological assessment

Juliana Casseb Oliveira 15 February 2012 (has links)
Introdução: Existem muitas controvérsias sobre a dislexia. Uma delas é justamente saber se a dificuldade está no processamento auditivo de forma geral ou especificamente para a percepção de diferenças temporais de sons de fala e se a dificuldade é específica para mudanças rápidas temporais ou abrangem uma gama mais ampla de processamento auditivo. Objetivos: Os objetivos desse estudo foram comparar o desempenho de crianças com dislexia (Grupo Estudo) e com desenvolvimento típico (Grupo Controle) em testes comportamentais de Processamento Auditivo (Central) e comparar o desempenho do Grupo Estudo e do Grupo Controle em teste de Potenciais Evocados Auditivos de Longa Latência. Métodos: Participaram desse estudo 22 indivíduos disléxicos e 16 sem queixas ou alterações de leitura e escrita. Todos os indivíduos foram submetidos à avaliação de Processamento Auditivo (Central) comportamental e eletrofisiológica. Resultados: Para os testes comportamentais, houve diferença estatisticamente significante para o Teste Padrão de Frequência, e verificamos diferença estatisticamente significante somente para a Orelha Esquerda entre os resultados dos grupos Estudo e Controle para o Teste Dicótico de Dígitos, sendo que o Grupo Estudo apresentou um pior desempenho. Para os Potenciais Evocados Auditivos de Longa Latência encontramos diferença para os valores de Latência de N2 entre os grupos Estudo e Controle, sendo que o Grupo Estudo apresentou maiores valores de latência. Esse achado foi estatisticamente significante somente para Orelha Direita. Conclusões: Podemos sugerir que os disléxicos apresentam alteração de processamento auditivo temporal e não podemos afirmar que não há comprometimento de outras habilidades / Introduction: There are several controversies about dyslexia. One of them is knowing whether the difficulty is in the general auditory processing or specifically in the perception of temporal differences of speech sounds, and whether the difficulty is specifically for rapid temporal changes or involves a broader range of auditory processing. Aims: The aims of this study were to compare the performance of children with dyslexia (Study Group) and of children with typical development (Control Group) in behavioral tests of (Central) Auditory Processing, and to compare the performance of Study Group and Control Group in Long Latency Auditory Evoked Potentials. Methods: 22 individuals with dyslexia and 16 individuals with no reading and writing complaints or disorders took part in the study. All individuals underwent behavioral and electrophysiological assessment of (Central) Auditory Processing. Results: Concerning the behavioral tests results in both groups, there was a significant statistical difference for the Frequency Pattern Test and for the Left ear in the Dichotic Digit test, with a worse performance observed in the Study Group. Considering the Long Latency Auditory Evoked Potentials, there was a difference for the N2 latency values between the Study Group and the Control Group, with greater latency values in the Study Group. This finding was statistically significant only for the Right ear. Conclusions: We may suggest that individuals with dyslexia present temporal auditory processing disorder, however we cannot affirm absence of disorders in other skills
77

Medidas de imitância acústica de banda larga em crianças com perda auditiva sensorial severa e profunda e diferentes achados timpanométricos / Wideband acoustic immittance measurements in children with severe and profound sensorineural hearing loss, and different tympanometric findings

Eliene Silva Araujo 27 February 2015 (has links)
A avaliação da integridade do sistema tímpano-ossicular é um pré-requisito para que o processo de diagnóstico audiológico infantil possa ser concluído com precisão, assim, muito têm se discutido em relação aos procedimentos utilizados na prática clínica para definir a presença ou ausência de problema condutivo. Nesse sentido, as medidas de imitância acústica de banda larga mostram-se como uma opção para o avanço na área. Diante disso, surgiu o interesse em ampliar os conhecimentos e trazer as características das medidas de imitância acústica de banda larga nas diferentes condições de orelha média. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em crianças com perda auditiva sensorial de grau severo e profundo e diferentes padrões timpanométricos. Foram avaliadas 187 orelhas de 98 crianças na faixa etária de seis a 60 meses de idade, subdivididas em grupos de acordo com a pressão e compliância obtidas na timpanometria com sonda de 226 Hz. As medidas de imitância acústica de banda larga foram realizadas por meio do sistema de medidas do Acoustics\' Middle-Ear Power Analyzer - MEPA, versão 5.0, utilizando os estímulos tom puro e chirp, com faixa de frequência de 211 a 6000 Hz. Os valores de compliância e pressão obtidos na timpanometria convencional foram correlacionados às medidas de imitância acústica de banda larga, adotando-se testes estatísticos apropriados, com nível de significância de 0,05. Os resultados obtidos evidenciaram o efeito das faixas de frequência (grave, média e aguda) em todas as medidas analisadas, com exceção do delay da reflectância. Foi constatada influência de pressões correspondentes a -100 daPa ou mais negativas e também para pressões positivas acima de 25 daPa, e compliâncias menores que 0,2 ml nas medidas de imitância acústica de banda larga. Além disso, houve diferença significante entre os estímulos tom puro e chirp para frequências baixas para a absorvância e magnitude da impedância, com maior reflexo da variação dos valores de compliância e pressão nos resultados obtidos com estímulo chirp. Conclui-se que as características das medidas de imitância acústica de banda larga estão relacionadas à condição de orelha média e a frequência do estímulo teste. Para o delay da reflectância observou-se uma ampla variabilidade entre frequências ao analisar os grupos subdivididos pela pressão e também na frequência de 258 Hz ao analisar os grupos subdivididos pela compliância. / The evaluation of the integrity of the tympanic-ossicular system is a prerequisite for the child audiology diagnostic process to be completed accurately, thus, much has been discussed in relation to the procedures used in clinical practice to define the presence or absence of conductive problems. Hence, the wideband acoustic immittance measurements show to be an option to the advance in the field. As a result, the interest in expanding the knowledge and bringing the characteristics of wideband acoustic immittance measurements in the different conditions of middle ear, emerged. This study aimed at characterizing the wideband acoustic immittance measurements using pure and chirp stimuli in children presented with severe and profound sensorineural hearing loss and different tympanometric standards. 187 ears of 98 children in the age range six-sixty months, subdivided into groups according to pressure and compliance achieved through tympanometry with a 226 Hz probe, were assessed. Wideband acoustic immittance measurements were performed by the measuring system of the Acoustics\' Middle-Ear Power Analyzer - MEPA, version 5.0, using pure and chirp tone stimuli, in a frequency ranging from 211 to 6000 Hz. The values of compliance and pressure obtained through conventional tympanometry were correlated with wideband acoustic immittance measures, by applying suitable statistical tests, with a 0.05 significance level. The results achieved evidenced the effect of frequency bands (low, medium and high) in all measures examined, with the exception of the reflectance delay. The Influence of pressures -100 daPa or more negative ones and also in positive pressures above 25 Pa, and compliance lower than 0.2 ml in the wideband acoustic immittance measurements, was verified. In addition, there was a significant difference between pure tone and chirp stimuli at low frequencies for impedance absorbance and magnitude, with a greater reflex of the variation of compliance and pressure values in the results obtained with the chirp stimulus. It is concluded that the characteristics of broadband acoustic immittance measures are related to the condition of middle ear condition and the frequency of the test stimulus. For Reflectance delay, a wide variability between frequencies was observed when analyzing the groups subdivided by pressure and also in the frequency of 258 Hz, when analyzing the groups subdivided by compliance.
78

Teleaudiometria: um método de baixo custo para triagem auditiva / Teleaudiometry: a low-cost method of auditory screening

Victor Eulálio Sousa Campêlo 23 March 2009 (has links)
Introdução: Os benefícios da triagem auditiva neonatal e em escolares têm sido bem demonstrados, porém a disponibilização de programas de triagem auditiva tem sido restrita aos grandes centros, devido à escassez de equipamentos e profissionais especializados na maioria das localidades nos países em desenvolvimento. Para atingir estes objetivos, algumas iniciativas têm utilizado a telemedicina em diferentes soluções. No entanto, não existem relatos na literatura de métodos para avaliação auditiva à distância em que não se utiliza um periférico específico no ponto remoto, nem tampouco sem a necessidade de um profissional especializado de forma presencial ou remotamente. Objetivos: a) Desenvolver um método de triagem à distância para identificação de indivíduos com perda auditiva; b) Testar sua acurácia e compará-lo ao teste de audiometria de triagem (AV) sem cabine acústica. Material e Métodos: o novo método de triagem, denominado telaudiometria (TA), consiste em um software próprio desenvolvido, instalado em um computador com fone TDH 39. Foram selecionadas aleatoriamente entre pacientes e acompanhantes do Hospital das Clínicas, 73 pessoas entre 17 e 50 anos, sendo 42 (57,5%) do sexo feminino. Após serem submetidos a um questionário de sintomas e otoscopia, os indivíduos realizavam os testes de telaudiometria e audiometria de triagem com varredura em 20 dB nas freqüências de 1, 2 e 4 kHz seguindo o protocolo da ASHA (1997) e ao teste padrão-ouro de audiometria de tons puros em cabine acústica em ordem aleatória. Resultados: a TA durou em média 125 ± 11 s e a AV, 65 ± 18 s. Observou-se que 69 pessoas (94,5%) declararam ter achado fácil ou muito fácil realizar a TA e 61 (83,6%) consideraram fácil ou muito fácil a AV. Os resultados da acurácia da TA e AV foram respectivamente: sensibilidade (86,7% / 86,7%), especificidade (75,9% / 72,4%) e valor preditivo negativo (95,7% / 95,5%), valor preditivo positivo (48,1% / 55,2%). Conclusão: A teleaudiometria mostrou-se uma boa opção como método de triagem auditiva, apresentando acurácia próxima da audiometria de triagem. Em comparação a este método, a telaudiometria apresentou sensibilidade semelhante, maiores especificidade, valor preditivo negativo e tempo de duração e menor valor preditivo positivo. / Introduction: Hearing deficiency interferes with the perception and recognition of speech. The benefits of auditory screening in newborns and schoolchildren have been well demonstrated. However, in developing countries, the availability of auditory screening programs has been restricted to larger facilities, due to the scarcity of equipment and specialized professionals in the majority of areas. Objectives: To develop a method of remote screening for the identification of individuals with hearing loss, as well as to determine its accuracy in comparison with that of sweep audiometry without a sound-treated booth. Design: The new screening method, designated teleaudiometry, consists of its own newly developed computer program, installed on a computer with supra-aural headphones attached. The study participants were randomly selected from among patients and their companions at the University of Sao Paulo School of Medicine Hospital das Clínicas, in Sao Paulo, Brazil. We selected 73 individuals between 17 and 50 years of age, 42 (57.5%) of whom were female. After completing a symptoms questionnaire and being submitted to otoscopy, the participants underwent teleaudiometry and sweep audiometry with a sweep of 20 dB at the frequencies of 1, 2 and 4 kHz following the American Speech-Language-Hearing Association protocol, as well as the gold-standard test of pure tone audiometry in sound-treated booth, in random order. Results: The teleaudiometry lasted, on average, 125 ± 11 sec, compared with 65 ± 18 sec for sweep audiometry. Of the 73 participants, 69 (94.5%) found it easy or quite easy to perform the teleaudiometry, compared with 61 (83.6%) for the sweep audiometry. Teleaudiometry and sweep audiometry presented, respectively, the following: sensitivity of 86.7% and 86.7%; specificity of 75.9% and 72.4%; a negative predictive value of 95.7% and 95.5%; and a positive predictive value of 48.1% and 55.2%. Conclusions: Teleaudiometry proved to be a viable option as a method of auditory screening, presenting accuracy similar to that of sweep audiometry. The use of teleaudiometry could increase the number of identified cases of hearing loss, thereby allowing more timely treatment of such cases in underserved populations
79

RECONHECIMENTO DE FALA, HABILIDADES AUDITIVAS E COGNITIVAS EM ADULTOS BILÍNGUES / SPEECH RECOGNITION, HEARING AND COGNITIVE ABILITIES IN BILINGUAL ADULT INDIVIDUALS

Torres, Enma Mariángel Ortiz 22 January 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / OBJECTIVE: to verify and to compare the performance of monolingual and bilingual individuals in the recognition of situations of favorable listening (silence) and in situations of not favorable listening (noise), with their cognitive and listening abilities. MATERIAL AND METHOD: The present study is about an observational research, transversal, and descriptive, which compares the findings of monolingual and bilingual individuals. This group study was formed by 87 individuals between 18 and 55 years old, distributed in control groups, 30 monolingual Brazilian portuguese speaking and group study, 31 bilingual brazilian s portuguese and german speakers, and 26 bilinguals brazilian s portuguese and Italian speakers. The individuals were summoned to two different moments of surveying, initially the basic surveys for basic audio of recognition of speaking was made by the test lista de sentenças in portuguese (LSP). Furthermore, the survey about the audio assessment was analyzed and performed by using two tests, which are dissilabos alternados and sobrepostos (SSW) and teste dicotico de digitos (TDD). Afterwards, a survey about the cognitive abilities was performed, using the bateria de provas de reciocinio (BPR-5) test. RESULTS: The completed surveys made using the LSP test have had shown that bilingual individuals and monolingual individuals develop similar speaking performances, when summoned to silence, in the speaking recognition of speech in noise, there was a better verified performance of the bilingual groups in comparison to the monolinguals. Additionally, for the cognitive abilities there was a better performance of general cognition, with a slight statistic perceptual error, which favored bilinguals. In term of each one of the surveyed cognitive abilities, the verbal reasoning, spatial and mechanic showed a big statistic difference, which favored bilinguals. However, in logic and math, bilinguals and monolinguals did not show any divergence. In audio abilities, which were verified by SSW s test, there was a statistic significant difference, favoring bilinguals. CONCLUSION: After this research, one must acknowledge that bilingual and monolingual individuals present similar performances when it comes to hearing and understanding once the speech is presented in silence. When the speech is presented through noise, there were illustrating facts that bilinguals present better performance compared to monolinguals. In the cognitive field, we shall suggest that life experience in bilinguals might have influence over the cognitive performance and verbal judgment, spatial and mechanic, as well as in hearing abilities of attention and background figure. / OBJETIVOS: verificar e comparar o desempenho de indivíduos monolíngues e bilíngues no reconhecimento de fala em situações de escuta favoráveis (silêncio) e em situações de escuta não favoráveis (ruído), assim como suas habilidades auditivas e cognitivas. MATERIAL E MÉTODO: o presente estudo trata-se de uma pesquisa observacional, transversal, descritiva e quantitativa que compara os achados auditivos de indivíduos monolíngues e bilíngues. O grupo estudado foi composto por 87 indivíduos entre a faixa etária de 18 e 55 anos de idade, distribuídos em grupo controle, 30 monolíngues falantes do português brasileiro e grupo estudo, 31 bilíngues falantes do português brasileiro e do alemão e 26 bilíngues, falantes do português brasileiro e do italiano. Os indivíduos foram submetidos a dois momentos distintos de avaliação. Inicialmente, foram realizadas as avaliações auditivas básicas, de reconhecimento de fala através do teste Lista de sentenças em Português (LSP) e do processamento auditivo através do teste de Dissílabos Alternados e Sobrepostos (SSW) e posteriormente, efetuou-se a avaliação das habilidades cognitivas, através do teste Bateria de Provas de Raciocínio (BPR-5). RESULTADOS: as avaliações realizadas, através do LSP, demonstraram que indivíduos bilíngues e monolíngues apresentam desempenhos semelhantes na tarefa de reconhecimento de fala, quando avaliados no silêncio, já no reconhecimento de fala no ruído, foi verificado melhor desempenho dos grupos bilíngues, em relação aos monolíngues. Para a avaliação das habilidades cognitivas, verificou-se melhor desempenho da função cognitiva geral, com diferença estatisticamente significante, a favor dos bilíngues. Em relação a cada uma das habilidades cognitivas avaliadas, os raciocínios verbal, espacial e mecânico mostraram diferença estatisticamente significante a favor do grupo bilíngue, mas nos raciocínios matemático e abstrato os bilíngues e monolíngues não se diferenciaram. Nas habilidades auditivas, verificadas através do teste SSW, houve diferença estatisticamente significante a favor dos bilíngues. CONCLUSÕES: os achados da presente pesquisa verificaram que indivíduos bilíngues e monolíngues apresentavam desempenhos semelhantes no que concerne ao reconhecimento da mensagem ouvida, quando a fala é apresentada no silêncio. Quanto à fala no ruído, foram mostrados indícios positivos de que os bilíngues apresentavam melhor desempenho em relação aos monolíngues. No campo cognitivo, podemos sugerir que a vivência bilíngue parece ter influência no desempenho da função cognitiva geral e nos raciocínios verbal, espacial e mecânico, assim como nas habilidades auditivas de atenção, memória e figura- fundo.
80

Validity of diagnostic pure tone audiometry using a portable computerised audiometer without a sound-treated environment

Maclennan-Smith, F.J. (Felicity Jane) January 2013 (has links)
It is estimated that 10% of the global population is impaired to a significant degree by a decrease in hearing sensitivity. With the greatest proportion of these persons residing in developing countries where communities are grossly underserved, it is incumbent on hearing healthcare professionals to seek means of offering equitable hearing health care services to these communities. The delivery of conventional diagnostic hearing services to these population groups is challenged by limitations in human resources, financial constraints and by the dearth of audiometric testing facilities that are compliant with permissible ambient noise levels for reliable testing. Valid diagnostic hearing assessment without an audiometric test booth will allow greater mobility of services and could extend hearing healthcare service delivery in underserved areas. The purpose of this study was to investigate the validity of diagnostic pure tone audiometry in a natural environment, outside a sound treated room, using a computer-operated audiometer with insert earphones covered by circumaural earcups incorporating real-time monitoring of environmental noise. A within-subject repeated measures research design was employed to assess elderly adults with diagnostic air (250 to 8000 Hz) and bone (250 to 4000 Hz) conduction pure tone audiometry. The study was of a quantitative nature and the required data was collected by testing subjects initially in a natural environment and subsequently in a sound booth environment to compare the threshold measurements. One experienced audiologist used audiometric KUDUwave test equipment to evaluate subjects in both environments. A total of 147 adults with an average age of 76 (± 5.7) years were tested. Ears had pure tone averages (500, 1000, 2000 and 4000 Hz) of ≥ 25 dB in 59%, >40 dB in 23% and ˃ 55 dB in 6% of cases. Analysis of collected data showed air conduction thresholds (n = 2259) corresponding within 0 to 5 dB in 95% of all comparisons between testing in the natural and sound booth environments. Bone conduction thresholds (n = 1669) corresponded within 0 to 5 dB in 86% of comparisons and within 10 dB or less in 97% of cases. Average threshold differences (–0.6 to 1.1) and standard deviations (3.3 to 5.9) were within typical test-retest reliability limits. Recorded thresholds showed no statistically significant differences with a paired samples t-test (p ˃ 0.01) except at 8000 Hz in the left ear. Overall the correlation between the air-conduction thresholds recorded in the sound booth environment and the natural environment was very high (˃ 0.92) across all frequencies while for bone conduction threshold correlation for the two environments fell between 0.63 and 0.97. This study demonstrates that valid diagnostic pure tone audiometry in an elderly population can be performed in a natural environment using an audiometer employing insert earphones covered by circumaural earcups with real-time monitoring of ambient noise levels. Mobile diagnostic audiometry performed outside of an audiometric sound booth may extend current hearing healthcare services to remote underserved communities where booths are scarce or inaccessible. In combination with Telehealth applications this technology could offer a powerful and viable alternate diagnostic service to persons unable to attend conventional testing facilities for whatever reasons. / Dissertation (MCommunication Pathology)--University of Pretoria, 2013. / gm2014 / Speech-Language Pathology and Audiology / Unrestricted

Page generated in 0.1677 seconds