• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 46
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1888
  • 854
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
841

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Bohner, Lauren Oliveira Lima 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
842

Estudo comparativo da interação celular entre quatro tipos de implantes dentários / Comparative study of cellular interactions between four types of dental implants

Alves, Fabiana Ferreira 26 February 2015 (has links)
O tratamento de superfície dos implantes dentários é um critério importante para a osseointegração. Considerando a variedade de modificações das superfícies encontradas, estas podem acelerar ou melhorar o processo de osseointegração. Para tanto foram estudadas as características da composição química e a rugosidade, a partir das quais foram encontradas diferentes respostas celulares em estudos comparativos in vitro. O objetivo deste estudo foi comparar a adesão e o crescimento dos OSTEO-1 em implantes dentários com diferentes tratamentos de superfície. Foram utilizados quatro tipos de implantes dentários comercialmente disponíveis, com os seguintes tratamentos de superfície: (A) jateamento e condicionamento ácido com revestimento de fosfato e cálcio (CaP); (B) duplo condicionamento ácido; (C) condicionamento ácido; (D) oxidação anódica. Os implantes de mesmo tamanho foram fixados com dispositivo biocompatível no fundo dos poços das placas de cultura de 12 poços e cobertas com meio de cultura de células. Os OSTEO-1 foram colocados no corpo do implante. Nos períodos de 24, 48 e 72 horas mais tarde, as culturas foram submetidas ao ensaio de redução de MTT para avaliar a viabilidade celular. Os dados foram utilizados para analisar a adesão celular (24h) e para obter as curvas de crescimento das células (24, 48 e 72h). Os experimentos foram realizados em triplicata. Os dados foram comparados por ANOVA, complementado pelo teste de Tukey (p <0,05). Os OSTEO-1 aderiram ao corpo de todos os tipos de implantes testados. A maior taxa de crescimento celular foi observada em culturas semeadas sobre tratamento de superfície A. O menor crescimento celular foi apresentado por culturas semeadas no tratamento de superfície D (p <0,05). Com base nesta investigação in vitro é possível concluir que todos os implantes dentários testados, independentemente do tratamento de superfície, não são citotóxicos para os OSTEO-1. No entanto, as características físico-químicas do tipo de tratamento de superfície dos implantes dentários influencia o crescimento celular. A superfície A pareceu ter o comportamento mais compatível com os OSTEO-1, uma vez que promoveu mais crescimento celular. / The surface treatment of dental implants is a major feature for osseointegration. The variety of surface modifications found may be speed up or enhance the osseointegration process. In much was studied the chemical composition and characteristics of roughness, from which found different cellular responses in comparative studies in vitro.The aim of this study was to compare the adhesion and growth of osteoblast-like cells in response to dental implants characterized by different superficial treatments. Four types of dental implants with different superficial treatments were used. The commercially available implants presented the following superficial characteristics: (A) sandblasted with acid-etched and calcium phosphates (CaP) coating; (B) double acid-etched; (C) anodized, or (D) acid-etched. The implants of the same size (n= 3 per group/experimental time) were fixed with a biocompatible device on the bottom of the wells of 12 wells cell culture plates and covered with cell culture medium. Osteoblast-like cells (Osteo 1 cell line) were plated on the top of the implants (5x104 cells/implant). Twenty-four, 48 and 72 hours later, the cultures were submitted to the MTT reduction assay to assess cell viabilities. Data was used for analyze cell adhesion (24 h) and to obtain cell growth curves ( 24, 48 and 72 h). The experiments were done in triplicate. Data were compared by ANOVA complemented by the Tukey\'s test (p<0.05). Osteoblast-like cells adhered on the top of all types of implants tested. The highest cell growth was observed in cultures plated on the top of sandblasted with acid-etched and CaP coating surfaces. The smallest cell growth was presented by cultures plated on double acid-etched surfaces (p < 0.05). Based on this in vitro investigation, it is possible to conclude that all dental implants tested irrespective to the surface treatment, are non-cytotoxic for osteoblast-like cells. However, the physicochemical chacteristics of the type of dental implants surface treatment influences the cell growth. In fact, the surface treated by sandblasting with acid-etched and CaP coating seemed to the most compatible with osteoblast-like cell biology, once it promoted the highest cell growth.
843

O bombardeamento da superfície de titânio com íons de argônio influencia a resposta biológica de pré-osteoblastos / Argon ions bombardment of titanium surface influences preosteoblastic biological behavior

Moura, Carlos Eduardo Bezerra de 14 December 2007 (has links)
As propriedades da superfície do implante têm papel crítico na indução das respostas celulares necessárias para o sucesso do implante. Os objetivos deste trabalho foram investigar o efeito do bombardeamento com íons de argônio sobre a superfície de titânio comercialmente puro (TiCP) e sua influencia na interação célula-superfície. Superfícies bombardeadas e lisas foram avaliadas quanto à topografia, rugosidade e molhabilidade. Ensaios de adesão, proliferação, atividade de fosfatase alcalina (ALP) e expressão de osteocalcina (OC) foram conduzidos usando células MC3T3-E1 cultivadas sobre essas duas diferentes superfícies. Os níveis de rugosidade na superfície bombardeada e lisa foram 0,11µm and 0,027µm, respectivamente. A Microscopia eletrônica de Varredura (MEV) e Microscopia de força atômica (AFM) também revelaram rugosidade uniforme nestas amostras. A molhabilidade foi maior na superfície bombardeada. O número de células aderidas (30 e 60 min) foi significativamente maior sobre a superfície bombardeada. A proliferação celular depois de 3 e 7 dias também foi maior na superfície bombardeada. A atividade de ALP e expressão de OC não apresentaram diferença significativa entre as superfícies. Esses dados nos levam a propor que a técnica processamento a plasma em atmosfera de argônio com uso de cátodo planar é uma excelente ferramenta para obtenção de biomateriais que favoreçam a osseointegração. / Titanium surfaces were modified by argon ions bombardment aiming to evaluate the influence of the treatment on cell-surface interaction. The effects of topographic (roughness, microstructure) and physiochemical (wettability - contact angle) parameters on the morphology, adhesion, proliferation and MC3T3-E1 preosteoblasts differentiation were analyzed. No-treated surfaces (smooth) were used as a control. The levels of roughness observed in bombarded and smooth titanium surfaces were of 0.11µm and 0.027µm respectively. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) analysis showed that the roughness distribution was uniform. The wettability increased in treated surfaces. The number of attached cells (30 and 60min) was significantly higher on the bombarded surface, as well as, cell proliferation after 3 and 7 days was also significantly higher on ion-bombarded surface. The ALP activity and OC expression did not show not significant differences between the surfaces. Based on the results showed one can propose that the bombardment of titanium surfaces with argon ions is an excellent procedure for obtaining biomaterials and improve the osseointegration.
844

Análise histológica e histomorfométrica da osseointegração de implantes de titânio inseridos na tíbia de ratos Wistar induzidos por ácido zoledrônico e dexametasona / Histologic and histomorphometric analysis of the osseointegration of endosseous implants placed on the tibiae of Wistar rats treated with zoledronic acid and dexamethasone

Oliveira, Marcio Augusto de 03 December 2012 (has links)
A terapia com bisfosfonatos tem sido frequentemente empregada no tratamento de doenças metabólicas do osso e neoplasias malignas. O objetivo deste estudo foi avaliar através de análise histológica e histomorfométrica em cortes não descalcificados, a influência dos bisfosfonatos nitrogenados endovenosos associados ou não a dexametasona sobre a osseointegração de implantes instalados em tíbias de 27 ratos Wistar. Ácido zoledrônico e dexametasona foram administrados por via subcutânea nos animais dos grupos experimentais. Os animais foram acompanhados por 7, 14 e 28 dias. Nossos resultados mostraram que não houve falha na osseointegração em nenhum animal avaliado e que não foram observadas diferenças estatisticamente significantes entre os 3 grupos com relação à quantidade de contato entre osso e implante e presença de osso em áreas pré determinadas, nos tempos observados. No entanto nossas observações histológicas revelaram que nos animais tratados com bisfosfonatos associados ou não com dexametasona, aos 14 e 28 dias após a colocação do implante não ocorreu o fenômeno de remodelação da cortical óssea, ao contrário do grupo controle. Concluímos que a terapia com bisfosfonatos associada ou não com dexametasona não impediu a osseointegração do implante com o osso mas inibiu severamente a remodelação da cortical óssea pré existente. / Bisphosphonate therapy has been often employed in the treatment of metabolic bone diseases and malignancies. The aim of this study was to evaluate through histological and histomorphometric analysis the influence of intravenous nitrogen-containing bisphosphonates alone or combined with dexamethasone on the osseointegration of implants placed in the tibia of 27 male Wistar rats in non decalcified samples. Zoledronic acid and dexamethasone were administered through sub cutaneous injections. The animals were followed through 7, 14, and 28 days. Our results showed that there was no failure in osseointegration in any animal, and that there were no statistically significant differences among the 3 groups regarding the amount of bone-implant contact and peri-implant bone density in predetermined areas. However our histological observations revealed that animals treated with bisphosphonates, associated or not with dexamethasone, at 14 and 28 days after implant placement has not occurred the phenomenon of cortical bone remodeling, unlike control group. We conclude that bisphosphonate therapy associated or not with dexamethasone did not prevent osseointegration of the implants but severely inhibited the remodeling of pre-existing cortical bone.
845

Développement de biomatériaux nanostructurés pour la régénération osseuse et ostéo-articulaire / Development of nanostructured biomaterials for bone and osteo-articular regeneration

Facca, Sybille 05 November 2012 (has links)
L'ingénierie tissulaire a vu émerger dans la dernière décennie, la nanomédecine régénérative en combinant non seulement les cellules souches mais aussi les facteurs de croissance. Le but de ce travail a été d'utiliser les techniques de l'ingénierie osseuse et cartilagineuse pour améliorer ou créer des biomatériaux en les rendant bioactifs et vivants à une échelle nanométrique. Durant ce travail de thèse, nous nous sommes intéressés au développement de biomatériaux (naturels ou synthétiques), tridimensionnels (3D), implantables et utilisables pour le traitement de diverses pathologies de l'appareil loco-moteur, qui sont capables d'induire une meilleure différenciation cellulaire et une régénération tissulaire plus stable. Nous avons développé 3 types d'implants nanostructurés, à base de titane recouvert d'hydroxyapatite et de nanotubes de carbone, de capsules ou de membranes nanofibreuses nanofonctionnalisées par des facteurs de croissance, qui ont permis d'obtenir une régénération osseuse ou ostéo-articulaire, in vitro comme in vivo / During the last ten years, tissue engineering has merged with regenerative nanomedecine by combination, not only of stem cell technology but also of growth factors. The goal of this thesis was to use bone and cartilage engineering as a model, in order to improve and to develop active and living nanostructured implants. During this PhD studies, we were interested in the development of biomaterials (natural or synthetic), tridimentionnal (3D), transplantable for bone and cartilage diseases treatments, that are able to induce more cellular differentiation and improved tissue regeneration. In this thesis, we have developed 3 types of nanostructured implants, (i) titanium implants coated with hydroxyapatite and carbone nanotubes; (ii) active capsules functionalized by growth factors and stems cells for bone induction (in vitro/in vivo); (iii) electrospun nanofibrous membranes functionalized by growth factors and (Osteoblasts/Chondrocytes) for bone and cartilage regeneration, in vitro and in vivo
846

Etude théorique et expérimentale des implants médicaux actifs en environnement électromagnétique : application aux défibrillateurs implantables en champ magnétique basse fréquence dans la bande 50Hz - 50kHz / Experimental and theoretical modelling of active medical implants within an electromagnetic environment : Application to implantable defibrillators in the 50 hz-50 khz range

Katrib, Juliano 13 October 2011 (has links)
Ce travail de thèse s'inscrit dans un contrat entre l'équipe "Mesures électroniques" du LIEN (EA3440) et le service de la Recherche et celui des Études Médicales de la société EDF. Il porte sur le comportement des défibrillateurs implantables en environnement magnétique basse fréquence (50 Hz-50 kHz). Un premier chapitre introduit les principes des interactions entre les champs électromagnétiques et les implants médicaux actifs. Il résume les données constitutives d'une étude comportementale des implants médicaux actifs en présence d'un champ électromagnétique. Y sont présentées et définies les données générales ou spécifiques aux sources électromagnétiques et aux dispositifs médicaux implantables. Un souci est de déterminer les champs et/ou les courants électriques induits dans un modèle du corps humain par une source magnétique basse fréquence (50 Hz à 50 kHz), c'est l'objet du chapitre 2. Ces calculs sont basés sur un modèle par les intégrales finies simulé à l'aide du logiciel CST. Un fantôme virtuel utilisant les conductivités de 77 organes différents a été construit grâce au Visible Human Project. La prise en compte de l'implant est effectuée au chapitre 3. Partant des résultats précédents, un défibrillateur implantable est inséré dans le modèle virtuel en vue de calculer les tensions induites en bout de sonde. Ces tensions sont comparées aux données normatives et montrent leur valeur très faibles quelle que soit la fréquence du champ magnétique. Le quatrième et dernier chapitre présente les résultats de validation expérimentale obtenues par des tests in vitro dans un fantôme électromagnétique au sein d'une cage de Faraday. Un signal cardiaque leurre est généré artificiellement. Un banc de mesure est configuré et géré par un logiciel d'instrumentation virtuelle sous GPIB (HPVEE). Il permet de contrôler la puissance de la source et de recueillir les signaux via la télémétrie du défibrillateur. Quelques épisodes réversibles ont été observés à 50 Hz montrant la grande sensibilité de l'électronique (filtre d'entrée) selon les modèles destinés à l'Europe (50 Hz) ou aux USA (60 Hz). Ceci est normal ces valeurs correspondant aux fréquences cardiaques. Les séries de mesures effectuées n'ont montré aucune défaillance pour les 4 défibrillateurs testés pour des puissances pouvant atteindre jusqu'à 3,44 mT. / This thesis was conducted under a contract between the "Electronic Measurements" Research Group within the Electronic Instrumentation Laboratory of Nancy and the Research Department of EDF. The focus of this thesis is the behavior of implantable defibrillators in low frequency (50 Hz-50 kHz) magnetic environments. The first chapter introduces the principles and summarizes the basics of the interactions between electromagnetic fields and active medical implants. General and specific data concerning implantable medical devices are also presented. The main aim of the second chapter is to determine the fields and/or electric currents induced in a human body by a magnetic source at low frequency (50 Hz to 50 kHz). The calculations are based on a finite integral method elements model using CST software. In the third chapter, a virtual phantom is described, based on 77 different organs. It is constructed using the Virtual Family. Based on the above results, an implantable defibrillator is inserted into the virtual model to calculate the voltages induced at the end of the probe. These voltages are compared with threshold values obtained from the Standards to demonstrate their very low values regardless of the frequency of the magnetic field. The fourth and final chapter presents the results obtained for experimental validation with in vitro tests in an electromagnetic phantom made of gelatin, placed within a Faraday cage. A cardiac signal is generated as an artificial lure. The experimental set up is configured and managed by virtual instrumentation (GPIB HPVEE). It controls the power source and collects telemetry signals via the defibrillator. Some reversible episodes were observed at 50 Hz showing the sensitivity of the electronics (input filter) according to the ICD models destined for Europe (50 Hz) and the USA (60 Hz). These are normal values for heart rate. The series of measurements showed no failure for four defibrillators tested in electromagnetic fields up to 3.44 mT
847

Avaliação da deformação gerada na região peri-implantar de prótese fixa implantossuportada, com a utilização de extensômetros lineares elétricos / Evaluation of peri-implant bone deformation of a mandibular cantilevered implant-supported prosthesis, with the use of strain gages

Suedam, Valdey 07 August 2009 (has links)
O comportamento mecânico das próteses parciais fixas implanto-suportadas são foco de vários estudos, onde o entendimento do processo de transmissão de forças mastigatórias e suas reações na estrutura óssea peri-implantar ainda não são totalmente compreendidos. Por isso, o objetivo deste trabalho foi verificar a deformação gerada na região peri-implantar de prótese parcial fixa mandibular. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes hexágono externo de 3,75mm de diâmetro por 13mm de comprimento, nos quais foram fixados intermediários multi-unit. O trabalho apresentou dois grupos divididos de acordo com o tipo de liga das infraestruturas (CoCr ou PdAg) os quais foram submetidos a quatro situações de aplicação de carga. Foram aplicadas forças de 300N, nos pontos de referência pré-determinados na barra entre os implantes e na extremidade livre (5mm, 10mm e 15mm de cantilever). Foram realizadas leituras das deformações geradas na distal, lingual, mesial e vestibular de cada implante, com o uso de extensômetros lineares elétricos, as quais foram correlacionadas com a teoria de remodelação óssea proposta por Frost. Os resultados do estudo demonstraram que a deformação é influenciada pelo ponto de aplicação de carga e pelo módulo de elasticidade da liga da barra. A deformação é diretamente proporcional ao comprimento do cantilever, onde comprimentos maiores do que 10mm provocam tensões que superam a tensão máxima fisiológica proposta pela teoria de Frost. / The mechanical behavior of implant-supported prosthesis is focus of some studies, with the process of bite forces transmissions and its peri-implant bone reactions is not completely understood yet. Therefore, the aim of this study was to verify the deformation in peri-implant region of mandibular fixed partial prosthesis. A U shaped polyurethane model was used to simulated the mandibular bone with two external hexagon implants with 3.75mm of diameter an 13mm of length, provided with multi-unit abutments. Two groups were formed according to the type of alloy of the framework (CoCr or PdAg), which were submitted to four load conditions. Loads of 300N were applied, in the predetermined points on the framework between the implants and the cantilever (5mm, 10mm and 15mm distal to the terminal implant). Readings of the deformations generated on the distal, lingual, mesial and bucal aspects of each implant were obtained with the use of strain gages, which were correlated to the theory proposed by Frost on bone remodeling. The results of the study demonstrated that deformation is influenced by the point of load application and by the elastic modulus of the alloy of the framework. The deformation is directly proportional to the cantilever length. Lengths bigger than 10mm generate tensions that exceed the maximum effective strain proposed by Frost.
848

Monitoramento histológico, histomorfométrico e radiográfico da cicatrização óssea ao redor de mini-parafusos ortodônticos autoperfurantes, submetidos ou não à aplicação de carga imediata, em tíbias de coelhos / Histological, histomorphometric and radiographic monitoring of bone healing around self-drilling orthodontic mini-screws, subjected or not to immediate load in rabbit tibiae

Catharino, Priscilla Campanatti Chibebe 25 May 2012 (has links)
Mini-implantes ortodônticos são acessórios de ancoragem esquelética. O objetivo deste estudo foi descrever a cicatrização óssea inicial ao redor dos mini-implantes, esterilizados pelos pesquisadores, submetidos ou não à aplicação de carga imediata. Foram inseridos 144 mini-implantes autoperfurantes (TOMAS®, Dentaurum, Germany) nas tíbias de dezoito coelhos brancos. Carga imediata (50 cN) foi aplicada sobre 50% dos mini-implantes. Quatro coelhos foram sacrificados em cada tempo pós-cirúrgico: dias 15, 21, 30 e 60, e dois no dia 0, constituindo grupo controle. Radiografias digitais foram obtidas para mensuração da espessura da cortical óssea (ECO), contíguo aos mini-implantes e equidistante deles. Nas imagens digitais das lâminas histológicas, realizou-se análise histológica e histomorfométrica. Quantidade de osso (QO), contato osso-implante (BIC) e ECO foram analisados pelos testes t-pareado, ANOVA e coeficiente de correlação de Pearson. Aos 0 e 15 dias haviam áreas de fraturas da borda da cortical. Após 30 dias houve deposição de osso imaturo, que se apresentou maduro aos 60 dias. QO foi maior com carga aos 15 dias (p = 0,034); e aumentou ao longo da cicatrização, nos grupos com (p =0,004) e sem carga (p<0,001). Carga não afetou BIC; os valores aumentaram no decorrer do tempo, nos grupos com (p<0,001) e sem carga (p=0,001). ECO aumentou em todas as regiões (p<0,001). ECO próximo aos miniimplantes foi maior que no ponto médio, exceto aos 15 dias sem carga (p = 0.077). Concluiu-se que carga imediata leve não comprometeu a cicatrização óssea ao redor dos mini-implantes. Ósseointegração e o aumento da espessura da cortical óssea foram tempo-dependentes. / Mini-implants are attachments for orthodontic anchorage. This study aimed to describe the initial bone healing around mini-implants sterilized by the researchers, submitted or not to application of immediate loading. Were inserted 144 self-drilling mini-implants(TOMAS®, Dentaurum, Germany) in the tibia of eighteen white rabbits. Immediate loading (50 cN) was applied to 50% of mini-implants. The animals were sacrificed at each time post-surgery: day 15, 21, 30 and 60, and two on day 0, being the control group. Digital radiographs were obtained to measure the thickness of cortical bone (ECO), adjacent to mini-implants and equidistant from them. In digital pictures from histological slides histology and histomorphometry was analyzed. Amount of bone (QO), bone-implant contact (BIC) and ECO were analyzed by paired t-test, ANOVA and coefficient of Pearson correlation. At 0 and 15 days had shear areas. After 30 days there was deposition of immature bone, which appeared mature at 60 days. QO load was greater at 15 days (p = 0.034), and increased over healing in load (p = 0.004) and unloaded groups (p <0.001). Load affected BIC, the values increased over time in groups with load (p <0.001) and unloaded (p = 0.001). ECO increased in all regions (p <0.001). ECO near the mini-implants was greater than at midpoint, except for 15 days without load (p = 0,077). It was concluded that light immediate loading did not affect bone healing around the mini-implants. Osseointegration and increased cortical bone thickness were time-dependent.
849

The self-regulation of a child with cochlear implants within a school environment

Unknown Date (has links)
The purpose of this qualitative research, which utilized a narrative design strategy, was to describe the process of self-regulation of a child who has bilateral cochlear implants within the social environment of school. The study investigated the use of self-regulatory strategies by the cochlear implant recipient. It also examined how the child made modifications and monitored learning during activities within the classroom as related to Vygotsky's activity theory and John Dewey's theory of social control. Through data collection of documents, observations, interviews, and researcher field notes, it was found that the child demonstrated several self-regulatory strategies. / Kristin L. Patton. / Thesis (Ph.D.)--Florida Atlantic University, 2013. / Includes bibliography. / Mode of access: World Wide Web. / System requirements: Adobe Reader.
850

Avaliação da estabilidade inicial de implantes instalados em modelos ósseos suínos padronizados em posicionamentos ao nível ou infraósseos / Evaluation of implants placed in bone standardized pig models in positions bone level or intraosseous using biomechanical tests and Micro-CT. An in vitro pilot study

Jessica Pires de Carvalho 25 August 2016 (has links)
A estabilidade primária é decorrente da adaptação mecânica imediata entre o osso e o implante após a sua inserção. O sucesso desta adaptação depende de fatores como a densidade e qualidade ósseas, tamanho, diâmetro, forma e rugosidade da superfície do implante. As cargas oclusais aplicadas sobre o implante podem afetar o osso circundante. Esse estudo teve como objetivo avaliar, comparativamente, a estabilidade inicial de implantes ósseo inseridos em cilindros de osso suíno padronizados, em diferentes posicionamentos ósseos, com e sem a aplicação de carga, por meio de análises de imagens tridimensionais (microtomografia computadorizada) e análises mecânicas (Frequência de ressonância, Torque de inserção e Ensaio de arrancamento). Os cilindros ósseos foram preparados a partir de osso suíno e separados em 2 grupos conforme a área doadora: Grupo A: cilindros removidos da cabeça do fêmur (alta densidade óssea) e Grupo B: cilindros removidos do côndilo mandibular (baixa densidade óssea). Previamente aos procedimentos experimentais, os cilindros ósseos foram certificados através de análises de imagens 2D (radiografia digital), para garantir a uniformidade intra-grupos e distinção entre os grupos dos espécimes. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: porcentagem de volume ósseo (BV/TV), separação trabecular (TbSp), razão entre a medida da área superficial do osso e o seu volume ósseo (BS/BV) e porcentagem de porosidade total (POTOT). Depois disso, foram selecionados 60 implantes, que foram divididos em 4 grupos, cada um com 15 implantes: G1 (cilindros ósseos de alta densidade com implante situados ao nível ósseo), G2 (cilindros ósseos de alta densidade com implante 2 mm infraósseo), G3 (cilindros ósseos de baixa densidade com implante ao nível ósseo) e G4 (cilindros de baixa densidade com implante 2 mm infraósseo). A instalação dos implantes seguiu o protocolo recomendado pelo fabricante e durante o procedimento foi realizada a medida do torque de inserção. Após a instalação dos implantes, os cilindros ósseos foram submetidos à nova análise tridimensional (com avaliação dos mesmos parâmetros anteriores, nas áreas intra-roscas e adjacente à estas, acrescidos da medida da área de contato ossoimplante (BIC). Foi então realizada a avaliação do Coeficiente de Estabilidade (ISQ), utilizando a análise de frequência de ressonância (Osstell®). Após essa avaliação, 5 implantes de cada grupo foram submetidos ao ensaio de arrancamento. Os 10 implantes de cada grupo restantes foram conectados a pilares protéticos adequados, os quais receberam uma aplicação de forças axial (G1, G2, G3 e G4, 5 implantes de cada grupo) e lateral (G1, G2, G3 e G4, 5 implantes de cada grupo). Após aplicação das forças, os cilindros ósseos foram submetidos a nova análise tridimensional com avaliação dos mesmos parâmetros descritos, a nova análise de frequência de ressonância e ao ensaio de arrancamento. As variáveis foram testadas em relação à normalidade dos dados. Para todas as análises foi considerado um nível de significância de 5%. As análises estatísticas foram realizadas com base nos dados absolutos obtidos durante a análise tridimensional em cada situação de carga (antes do implante, pósimplante e pós-carga) e com a variação entre os valores das situações pós-implante e póscarga (variação carga - implante). A avaliação estatística do parâmetro de análise de frequência de ressonância não encontrou diferenças estatisticamente significantes para as comparações entre grupos G1 versus G3 e G2 versus G4 nas avaliações pós implante e pós carga. Em relação ao torque de inserção, houve diferenças estatisticamente significantes para as comparações entre grupos com implantes instalados no mesmo nível G1 versus G3 e G2 versus G4. Os maiores valores de torque de inserção obtidos foram registrados nos grupos de alta densidade. A análise estatística do ensaio de arrancamento mostrou diferenças estatisticamente significantes para as comparações: G1 versus G3 (inicial) e G1 versus G4 (inicial). Após a aplicação de carga oclusal, pode-se constatar diferenças estatisticamente significantes para as comparações: G1 versus G3 e G2 versus G4, após aplicação de carga lateral a análise mostrou diferença estatisticamente significante para a comparação G3 versus G4. Os resultados das análises tridimensionais mostraram diferenças estatisticamente significantes para os parâmetros TbSp e POTOT na avaliação da área óssea intra-rosca. A avaliação dos dados de variação após a aplicação de carga oclusal e lateral para o parâmetro TbSp, mostrou diferenças estatisticamente significantes para as comparações G2 versus G4. Em relação ao parâmetro POTOT, a aplicação de carga oclusal e lateral mostrou diferença estatisticamente significante para as análises: G1 versus G2 e G2 versus G4. Em relação ao parâmetro BSBV a análise dos valores absolutos, mostrou diferenças estatisticamente significantes para a área óssea intra-rosca dos grupos de baixa densidade. Já a análise dos valores de variação, a aplicação de carga oclusal mostrou diferenças estatisticamente significantes para os grupos G1 versus G3, G2 versus G4 e G3 versus G4, enquanto a aplicação de carga não axial resultou em diferenças estatisticamente significantes para os grupos G3 versus G4 e G2 versus G4. Já a análise estatística dos dados de variação do parâmetro BV/TV, mostrou diferença estatisticamente significante para todas as comparações na área óssea intra-rosca após aplicação de carga oclusal e lateral. A análise estatística do parâmetro BIC mostrou diferenças significantes para os grupos de baixa densidade (G3 e G4) nas comparações pós implante e pós carga. Em relação aos dados de variação, pode-se constatar diferença estatisticamente significante na aplicação de carga axial para G1 versus G2 e G2 versus G4, enquanto a aplicação de carga lateral mostrou diferença estatisticamente significante para as comparações G1 versus G3 e G2 versus G4. De acordo com os dados obtidos pode-se concluir que a densidade óssea tem relação com a estabilidade primária de implantes, que cargas não axias são prejudiciais para o tecido ósseo peri-implantar e que o posicionamento infraósseo pode promover melhor resposta do tecido ósseo, principalmente em regiões de baixa densidade óssea. / With the increase of oral rehabilitation with implants, immediate load can be used to reduce the treatment time. It is important to perform correct treatment planning for immediate implant loading, using 3D image analysis. The subcrestal implant positioning is one of the possible factors that may impact the success of immediate loading implants. Objective: The aim of this study is to evaluate the initial stability of osseointegrated implants placed infra bone or at the bone level in standardized porcine bone cylinders, through image (microcomputerized tomography) and mechanical analysis (resonance frequency, insertion torque and pull out test). Sixty bone cylinders were prepared from fresh porcine bone and separated in 2 groups: Group A 30 cylinders removed from femur head (high bone density) and Group B - 30 cylinders removed from the mandibular condyle (low bone density). Before the experimental procedure, the bone cylinders were certificated through 2D images analysis (digital radiography) to calculated bone density. After this, the bone cylinders were evaluated through micro computed three-dimensional analysis before the implant insertion. The parameters were analyzed in 2 levels (L1-bone volume internal to the threads and L2 - immediately adjacent to the end of threads). The microtomographical parameters analyzed were: Bone volume/Total volume (BV/TV), Trabecular thickness (TbSp), Bone surface/Volume ratio (BS/BV) and Total porosity percent (POTOT). Then, 60 implants (Alvim, 3.5 mm x 10 mm, Neodent®, Curitiba) were inserted in bone cylinders (1 implant in each cylinder), according to manufacturers protocol, and insertion torque was recorded for each implant. After that, the bone cylinders were submitted a new micro computed tomography analysis that evaluated the same levels and parameters, and Bone Implant Contact (BIC) was also recorded. After that, 5 implants were submitted to pull out test while the others implants received axial and non- axial load. After that, a new microcomputerized tomography analysis evaluated the same levels and parameters previously described, and resonance frequency analysis and pullout test were performed in the bone cylinders. 3D analysis showed that pre- and post-implants intra-groups had statistically significant differences for TbSp and POTOT parameters, and for BSBV and BIC parameters there were observed statistically significant differences for low bone densities groups. The values of differences between post and before loading showed statistically significant differences between G2 and G4 for TbSp, POTOT, BSBV, BV/TV and BIC parameters. The RFA analysis showed highest values for G2 and G4. Concerning insertion torque, the highest mean values were found in high bone densities groups. The pullout strength test showed that the non- axial loads in the low bone density maybe lead to implant displacement throughout the implant insertion axis. Bone density has a direct relationship with implant primary stability. Non- axial loads are harmful to peri- implantar bone tissue and subcrestal placement of implants presented the best mechanical and tomographical results.

Page generated in 0.1072 seconds