• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 113
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1556
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Proposta de uma metodologia para comparar a capacidade de diferentes parafusos na manutenção da união do componente protético com o implante / A proposal of a methodology for comparing the ability of different screws in maintaining the implant/abutment joint

Felipe Miguel Pinto Saliba 23 February 2006 (has links)
As ocorrências de afrouxamento dos parafusos que unem as próteses aos implantes, são motivos de preocupação para os profissionais e empresas, as quais tentam minimizar o problema desenvolvendo e lançando no mercado parafusos que, se utilizados, supostamente diminuiriam a incidência de falhas nas próteses. Este trabalho desenvolve uma metodologia para se realizar ensaios de torque de remoção dos parafusos protéticos, com dois objetivos definidos: (1) isolar o comportamento do parafuso independente do dispositivo anti-rotacional (hexágono); (2) realizar uma transferência de carga de desparafusamento, estabelecendo uma movimentação ao conjunto, como acontece na boca e não somente ao parafuso protético. Para o emprego desta nova metodologia, utilizou-se 20 implantes com hexágono externo e 20 intermediários protéticos rotacionais (sem hexágono) retidos por 20 parafusos divididos em dois grupos: 10 parafusos de titânio (grupo 1) e 10 parafusos de titânio recobertos por lubrificante sólido TorqTite (grupo 2). Após o travamento do intermediário pelo parafuso, com um torque de 32 Ncm, o torque de remoção ao invés de ser aplicado no parafuso, foi aplicado no intermediário, através de uma chave que encaixava no intermediário e fazia com que o mesmo movesse no sentido do desparafusamento, eliminando a pré-carga e soltando o parafuso. Através dos resultados obtidos, pode-se observar que o grupo 2 obteve uma média dos valores do torque de remoção (48,47 Ncm 5,04) maior que o grupo 1 (38,62 Ncm 6,43), estabelecendo uma diferença significativa entre dois parafusos (p=0,001), mesmo com uma amostra reduzida, demonstrando-se a eficiência do método utilizado. / The occurrences of screws loosening that hold the prosthesis to the implants are concerning reasons for professionals and companies. In fact, companies are trying to minimize this problem by developing and launching screws that, if used, supposedly would reduce the prosthesis failures incidences. This work develops a methodology to achieve a loose tightening torque trial of prosthetic screw, with two defined objectives: (1) to isolate the screw behavior independently from the abutment hexagon; (2) to obtain a loose tightening transfer load, establishing a screw joint movement freedom, as it happens in the mouth, and not only on the prosthetic screw. In order to apply this new methodology, 20 external hexagon implants and 20 abutments without hexagon kept by 20 screws divided in two groups: 10 titanium screws (group 1) and 10 solid lubricated screws TorqTite (group 2). After the abutment fixation by the screw , with a 32 Ncm torque, the reverse torque, instead of being applied to the screw, was applied to the abutment with a key that fitted onto the abutment, making it move in a loose tightening direction, eliminating the preload and screw loosening. Taking the results into consideration, it was possible to see that group 2 had a reverse torque average value higher (48,47 Ncm 5,04) than group 1 (38,62 Ncm 6,43) establishing a significant difference between two screws (p=0,001), even for a small sample, showing the efficiency of the used method.
322

Análise comparativa da topografia e presença de impurezas de implantes dentais com superfície texturizada por meio de microscopia eletrônica de varredura (MEV)

Castro, Kavio Narciso de Oliveira January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-21T13:08:28Z (GMT). No. of bitstreams: 1 203835.pdf: 10797340 bytes, checksum: bfd0a2cbac605c338cdfb3cadf47f950 (MD5) / O objetivo desta análise comparativa foi observar qualitativamente, por meio de Microscopia Eletrônica de Varredura (MEV), as variações microscópicas topográficas e a presença de impurezas em cinco fabricantes de implantes osteointegráveis submetidos a diferentes processos de texturização: Conexão (Grupo 1); 3i (Grupo 2); Neodent (Grupo 3); SIN (Grupo 4); Titanium fix (Grupo 5). De acordo com os resultados foi possível concluir que, no aspecto topográfico os fabricantes SIN (G4) e 3i (G2) foram estatisticamente equivalentes, em um nível de significância de 1% e melhores que todos os demais, exibindo uma característica topográfica desejável. Os fabricantes Conexão (G1), Neodent (G3) e Titanium fix (G5) mostraram diferenças significantes entre si, em um nível de significância de 1% e padrões de texturização variáveis. No aspecto presença de impurezas os fabricantes Neodent (G3) e Conexão (G1) foram equivalentes entre si, em um nível de significância de 1% e melhores que todos os demais, mostrando superfícies mais livres de impurezas que todos os demais. Os fabricantes SIN (G4) e 3i (G2) foram equivalentes entre si, em um nível de significância de 1%, exibindo superfícies com uma certa quantidade de impurezas e melhores que o fabricante Titanium fix, que se mostrou inferior a todos os demais, exibindo superfícies com grande quantidade de impurezas.
323

Proposta protocolar para avaliar in vitro o crescimento e adesão celulares frente a implantes de titânio c.p. com quatro texturas superficiais obtidas por usinagem

Makowiecky, Edson January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T15:29:55Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:57:59Z : No. of bitstreams: 1 182038.pdf: 8962650 bytes, checksum: 18471b0f80e7a5054554eaf43450f159 (MD5) / A biocompatibilidade promove a oportunidade de investigar e comparar os resultados fenomenológicos gerados pelos estudos laboratoriais in vitro, investigações in vivo, em animais e, em humanos. Este trabalho situa-se entre estudos que visam beneficiar processos de osseointegração, fundamentais no desenvolvimento dos implantes, por meio de estudos in vitro. Trata-se da proposta de um protocolo para avaliar in vitro, em culturas de células osteoprogenitoras e células osteoblásticas provenientes de maxilares humanos, o crescimento e adesão celulares frente à quatro diferentes rugosidades obtidas por usinagem na superfície de amostras de cilindro de titânio c.p. seccionados.
324

Influência do tipo de conector na união dente e implantes de hexágono interno e externo: estudo pelo método da fotoelasticidade

Silva, Edmar Ferreira da [UNESP] 04 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-04Bitstream added on 2014-06-13T20:55:06Z : No. of bitstreams: 1 silva_ef_me_araca.pdf: 1411679 bytes, checksum: 3651a9f6c293e68c27d8e79e890167d0 (MD5) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / A união dente-implante ainda gera divergências de opiniões. A proposta deste estudo foi avaliar pelo método da fotoelasticidade a distribuição do stress entre implantes e dentes, nas próteses parciais fixas, comparando conectores rígidos e semi-rígidos e implantes de hexágono interno e externo. Para isto, foram confeccionados dois modelos com resina fotoelástica PL-2, um com implante de hexágono interno (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) e outro com implante de hexágono externo (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Três desenhos de próteses foram fabricados para cada modelo de implante, incorporando cada uma um tipo de conexão para unir implantes e dentes: 1) conexão rígida soldada; 2) conexão semi-rígida; 3) conexão rígida com parafuso oclusal. Os modelos foram colocados no polariscópio e cargas axiais de 100N foram aplicadas em pontos fixos na superfície oclusal das próteses. Os resultados mostraram tendência a uma menor intensidade nas tensões nas conexões semi-rígida e rígida soldada no modelo com implante de hexágono externo e maior intensidade nas tensões na conexão semi-rígida do hexágono interno. Dentro das limitações deste estudo, as seguintes conclusões foram obtidas: houve uma tendência a menor intensidade nas tensões na conexão semi-rígida e na conexão rígida soldada, no modelo com implante de hexágono externo; entre os três tipos de conexões no modelo com implante de hexágono interno, a conexão semi-rígida foi a mais desfavorável; na associação dente-implante é preferível a utilização do implante de hexágono externo. / The union tooth-implant still generate divergences of opinions. The purpose of this study was to examine for the photoelastic metod, the distribution of stress among implants and teeth, in the fixed partial prostheses, comparing rigid and semi-rigid connectors and internal and external hexagon implants. For this, two models were made with photoelastic resin PL-2, one with internal hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) and other with external hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Three drawings of prostheses were manufactured for each implants model, incorporating each an the connection type to unite implants and teeth: 1) rigid welded connection; 2) semi-rigid connection; 3) rigid connection with screw oclusal. The models were placed in the polariscope and axial loads of 100N were applied in fixed points in the surface oclusal of the prostheses. The results showed tendency to smaller intensity in tensions in the connections semi-rigid and rigid welded in the model with external hexagon implants and larger intensity in the connection semi-rigid of the model internal hexagon implant. The following conclusions were draw: there was tendency the smallest intensity in tensions in the semi-rigid connection and in the rigid welded connection in the model with external hexagon; among the three types of connections in the model with internal hexagon implants the connection semi-rigid was the most unfavorable; in the association tooth-implants it is preferable the use of external hexagon implants.
325

Avaliação do reparo ósseo de cavidades preenchidas por vidro bioativo ou osso liofilizado desmineralizado: análises biomecânica, microscópica e histométrica em cães

Mendes, Vanessa Cristina [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:41:42Z : No. of bitstreams: 1 mendes_vc_dr_araca.pdf: 2490243 bytes, checksum: 6ce7b53f4434b723ec9c25c37375666f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos do presente estudo foram analisar e comparar, em cães, a reparação óssea em defeitos preenchidos com vidro bioativo e osso desmineralizado liofilizado e comparar com áreas que não receberam biomateriais, antes e após a inserção de implantes dentários de titânio. Cavidades com 6mm de diâmetro foram realizadas em ambos os úmeros de 6 cães machos saudáveis e preenchidas com vidro bioativo, osso liofilizado desmineralizado e coágulo. Após 5 meses de reparação, foi removido tecido ósseo do centro das cavidades para análise de microscopia óptica. A seguir, implantes dentários de titânio foram colocados no centro dessas cavidades e em áreas de osso pré-existente. Três meses depois, realizou-se o teste biomecânico de contra-torque dos implantes. Os cães foram sacrificados e o tecido ósseo encaminhado para processamento e análise de microscopia eletrônica por retroespalhamento de elétrons. No teste biomecânico não foram observadas diferenças estatisticamente significantes entre os 4 grupos. A análise de microscopia óptica demonstrou a presença de ambos os biomateriais e tecido ósseo neoformado na maioria das amostras do grupo experimental. Na microscopia eletrônica por retro-espalhamento de elétrons observou-se neoformação óssea em todos os grupos. Pela análise histométrica, a quantidade de neoformação óssea no grupo do vidro bioativo foi estatisticamente maior em relação aos outros grupos. Concluiu-se que o vidro bioativo apresentou os melhores resultados em porcentagem de neoformação óssea. No entanto, uma reparação satisfatória foi demonstrada em todos os grupos, com adequada qualidade óssea ao redor dos implantes dentários. / The objectives of the present study were to analyze and compare, in dogs, the bone healing in large areas grafted with bioactive glass and DFDBA to areas without any grafting, before and after the insertion of titanium dental implants. Cavities (6mm diameter) were drilled in both humeri of 6 healthy male dogs. The cavities were filled in with bioactive glass, DFDBA and clot. After 5 months, bone was removed from the centre of the cavities and processed for light microscopy analysis. Titanium dental implants were placed in these sites and in areas not previously drilled. Three months later, a biomechanical test was performed and the force necessary to unscrew the titanium implants was measured. Dogs were sacrificed and the bone removed. After embedding in PMMA, calcified samples were cut in half and polished for back-scattering SEM analysis. No statistically significant differences were observed among the 4 groups concerning the biomechanical test, according to the test U of Mann- Whitney. Light microscopy analysis showed the presence of both biomaterials among the regenerated bone. In the back-scattering analysis, regenerated bone was seen in all groups, and DFDBA presented the least volume. Remnants of granules of bioactive glass were still present, but in a smaller size. Because granules of DFDBA have the same image density of bone, if present, they couldn’t be identified. According to the test U of Mann-Whitney, the amount of bone formation in the bioactive glass group was statistically higher compared to the other groups. Based on the findings of this study, it was concluded that the bioactive glass showed best results in terms of bone volume. However, a satisfactory regeneration of bone in large defects with adequate bone quality was observed around dental implants in all groups.
326

Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamente

Cardoso, Leandro de Carvalho [UNESP] 05 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-05Bitstream added on 2014-06-13T21:02:13Z : No. of bitstreams: 1 cardoso_lc_dr_araca.pdf: 1917765 bytes, checksum: a068b0645b4f20057a8f729027757d38 (MD5) / O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups.
327

Enxerto autógeno para aumento em espessura e ou altura do processo ósseo alveolar, transtornos de técnica cirúrgica, complicações e sobrevivência dos implantes

Moraes Júnior, Edgard Franco [UNESP] January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2002Bitstream added on 2014-06-13T20:21:54Z : No. of bitstreams: 1 moraesjunior_ef_dr_araca.pdf: 1027137 bytes, checksum: 69155df278e66cc86de2444a36139fb6 (MD5) / Foi realizado um estudo retrospectivo para avaliar os resultados da reconstrução do processo alveolar intensamente reabsorvido com diferentes tipos de enxerto ósseo autógeno associados à instalação de implantes simultâneos e mediatos (após 4 meses da instalação do enxerto) realizados no período de 4 anos e 6 meses. Foram selecionados para este estudo 84 pacientes, submetidos à reconstrução de defeitos ósseos dos maxilares, com enxertos ósseos do mento, linha oblíqua da mandíbula, crista ilíaca anterior e calota craniana, com um total de 346 implantes instalados, sendo que, 257 destes implantes encontravam-se, com as próteses implantossuportadas instaladas, e distribuídos em 40 implantes simultâneos e 217 mediatos. Desta forma, foram avaliadas os transtornos de técnica cirúrgica e as complicações relacionadas com as áreas receptoras, bem como a taxa de sobrevivência dos implantes. De acordo com os resultados obtidos, dentre alguns dos transtornos de técnica cirúrgica e complicações estavam a redução da quantidade de mucosa ceratinizada na cortical vestibular e conseqüente perda da profundidade de sulco, assim como, exposição parcial do enxerto, contaminação do enxerto, entre outras complicações verificadas. A taxa de sobrevivência, obtida para os implantes simultâneos e mediatos instalados, foi de 94,55%. Quando a taxa de sobrevivência foi avaliada individualmente para cada grupo, no caso dos implantes simultâneos foi encontrado um resultado de 97,50%, enquanto que para os implantes mediatos obteve-se um resultado de 94,10%%. Portanto com este estudo, conclui-se que dos transtornos de técnica cirúrgica com maior ocorrência estava a redução da quantidade de mucosa ceratinizada sobre a crista do rebordo, complicações como exposição parcial do enxerto entre outras, que as áreas doadoras intrabucais oferecem vantagem... / A retrospective study was carried out in order to evaluate the outcomes of the reconstruction of the severely resorbed alveolar ridge through different types of autogenous bone grafts associated to the placement of simultaneous and delayed implants (4 months after the bone graft procedure) accomplished during a period of 4 years and 6 months. A total of 84 patients were selected for the present study, which were submitted to reconstruction of the bone defects of the jaws by means of bone grafts from the chin, external oblique ridge, anterior iliac crest, cranial vault, adding up to 346 implants, from which 257 (40 simultaneous and 217 delayed implants), with the installed implant-supported prostheses. The evaluation concerned of the overturn of surgical technique and complications related to the receptor sites, as well as the survival rate of the implants. The results indicated occurrence of the overturn of surgical technique and complications such as reduction in the amount of keratinized mucosa over the buccal cortical plate with consequent decrease in vestibular depth, as well as partial exposure of the graft, contamination of the graft, and others. The survival rate for both simultaneous and delayed implants was 94.55%. Regarding the individual evaluation of each group, the simultaneous implants demonstrated a survival rate of 97.50% in relation to 94.10% for the delayed implants. The most frequent of the overturn of surgical technique were reduction in the amount of keratinized mucosa over the alveolar ridge, complications as partial exhibition of the graft among others, better performance of the intraoral donor sites in relation to the extraoral sites, positive association between implant failures and iliac crest grafts, besides significantly worse outcomes for the female subjects in relation to the males. Better results were observed for the simultaneous implants, what is in disagreement with previous studies.
328

Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães

Caneva, Marco [UNESP] 05 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 caneva_m_dr_araca.pdf: 5420643 bytes, checksum: 2a88c9a9a85203bfd0cd8f4fd62affa4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: avaliar a influência da instalação de implantes em alvéolos imediatamente após a extração do elemento dental na regeneração dos tecidos peri-implantares com implantes de diferentes configurações Material e métodos: Nos alvéolos distais dos quartos pré-molares mandibulares de cães, imediatamente após as extrações das raízes dentais, foram instalados implantes cilíndricos com 3,3 mm de diâmetro (grupo controle) e implantes cônicos com 5,0 mm de diâmetro (grupo teste). Foram avaliados histologicamente a regeneração dos tecidos duros e moles peri-implantares após 4 meses do procedimento cirúrgico. Resultados: Todos os implantes apresentaram-se osseointegrados ao tecido ósseo maduro mineralizado. A crista óssea alveolar sofreu reabsorção tanto no grupo teste como controle. A superfície óssea vestibular dos implantes do grupo teste (cônico; 3,6 mm) apresentou maior grau de reabsorção em comparação ao grupo controle (cilíndrico; 1,6 mm). As dimensões dos tecidos moles apresentaram-se semelhantes em ambos os grupos. No entanto, em relação ao ombro do implante, a mucosa peri-implantar localizou-se mais apicalmente no grupo teste em relação ao grupo controle. Conclusão: Este estudo confirmou que a distância entre a superfície do implante e o contorno externo da crista óssea alveolar vestibular influenciou no grau de reabsorção da tábua óssea vestibular. Conseqüentemente, em relação ao ombro do implante, a mucosa peri-implantar será estabelecida em um nível mais apical, se a distância entre a superfície do implante e o contorno externo da crista óssea alveolar for menor / Aim: the aim of the present experiment was to study the influence of implant installation into sockets immediately after tooth extraction on the healing periimplant tissues with implants of various configurations. Material & methods: Transmucosal cylindrical 3.3mm in diameter implants in the control sites, and conical 5.0mm in diameter in the test sites, were installed into the distal socket of the forth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant of the test sites (conical; 3.6mm) was more resorbed compared to the control sites (cylindrical; 1.6mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the periimplant mucosa was located more apically at the test compared to the control sites. Conclusion:The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level if the distance between the implant surface and the outer contour of the alveolar crest is small
329

Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cães

Lenharo, Ariel [UNESP] 03 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-03Bitstream added on 2014-06-13T19:22:06Z : No. of bitstreams: 1 lenharo_a_dr_araca_prot.pdf: 1956702 bytes, checksum: 5122f32b3aab14c8107085fded1a11c7 (MD5) / O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation.
330

Efeito do tratamento de superfície na osseointegração de implantes dentários da liga TI-7,5Mo

Oliveira, João Augusto Guedes de [UNESP] 27 January 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-01-27Bitstream added on 2014-06-13T19:03:28Z : No. of bitstreams: 1 oliveira_jag_dr_guara.pdf: 2054384 bytes, checksum: 2056494b4d46299584c8acf22e9f6838 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os Biomateriais Metálicos são utilizados para reforçar ou para restaurar a forma e função de tecidos duros. Os implantes e próteses são utilizados para substituir ombros, joelhos, quadris e dentes perdidos entre outros. Nos últimos anos, varias ligas de titânio para aplicações biomédicas foram avaliadas. Neste trabalho, a influência do tratamento de superfície biomimético na osseointegração de implantes dentários da liga Ti-7,5Mo foi avaliada. Os lingotes foram obtidos a partir de titânio e molibdênio utilizando um forno a arco voltaico. Eles foram submetidos a tratamento térmico e conformados a frio em prensa rotativa. Posteriormente foram confeccionados implantes (2,0 mm de diâmetro e 2,5 mm de comprimento) sob medida os quais submetidos ao tratamento de superfície biomimético. Os implantes foram inseridos e analisados histológica realizada após 28 dias. A caracterização microestrutural e mecânica da liga Ti-7,5Mo também foi realizada. Aliga Ti-7,5Mo exibiu baixo modulo de elasticidade e elevada relação resistência/modulo. O uso do tratamento de superfície biomimético promoveu um aumento da osseointegração sobre a superfície dos implantes / Metallic biomaterials are used to reinforce or to restore form and function of hard tissues. Implants and prosthesis are used to replace shoulders, knees, hips and teeth. In the last years, several titanium alloys for biomedical applications have been studied. In the present work, influence of biomimetic surface treatment in osseointegration of Ti-7.5Mo dental implant was evaluated. Ingots were obtained from titanium and molybdenum by using an arc-melting furnace. They were submitted to heat treatment and cold worked by swaging. Then, screw-shaped implants (2.0 mm diameter by 2.5 mm length) were custom made and they were submitted biomimetic surface treatment. Implants were implanted in the rat’s femur and histological analysis was realized after 28 days. Also, microstructural and mechanical properties of Ti-7.5Mo alloy were evaluated. Ti-7.5Mo showed low elasticity modulus and higher ratio strength/modulus. Results obtained suggest that Ti-7.5Mo exhibited excellent bulk properties. The use of the biomimetic surface treatment was able to promote an increase of osseointegration on surface of dental implants

Page generated in 0.0537 seconds