Spelling suggestions: "subject:"implantes"" "subject:"aimplantes""
361 |
Efecto de una intervención educativa sobre implante subdérmico en los conocimientos y actitudes de puérperas del Hospital San Juan de Lurigancho, julio 2017Vallejos Sánchez, Amanda Iris January 2018 (has links)
Publicación a texto completo no autorizada por el autor / Determina el efecto de una intervención educativa sobre implante subdérmico en los conocimientos y actitudes de puérperas del Hospital San Juan de Lurigancho en el mes de Julio del 2017. Realiza un estudio prospectivo, cuasi-experimental (pre prueba/ pos prueba) de un solo grupo; en 101 puérperas que cumplieron los criterios de selección. Se utilizó dos cuestionarios pre elaborados y validados, aplicados antes y después de la intervención educativa. Para el análisis de datos se usó la prueba de Wilcoxon, asumiendo una significancia p<0.05. La edad promedio fue de 26.37 ± 5.94 años; el 77.23% son convivientes (n=78); el 69.31% tiene secundaria completa (n=70). Se encontró una media de 2.21 ± 1.24 hijos por puérpera; el 54.46% no planificó el último embarazo. En relación al conocimiento, el puntaje obtenido presentó una mediana de 4 (RIQ: 3) en el pre-test y de 8 (RIQ: 2) en el post-test, obteniéndose variación significativa (p<0.01). Respecto a la variable actitud, se observó una mediana de 30 (RIQ: 10) en el pre-test y de 41 puntos (RIQ: 9) en el post-test, presentando también variación significativa (p<0.01). Concluye la intervención educativa sobre implante subdérmico generó un cambio positivo significativo en los conocimientos y actitudes de las puérperas del Hospital San Juan de Lurigancho. / Tesis
|
362 |
Tratamento biomimético de discos e implantes de titânio com alendronato : caracterização topográfica, estudo histométrico e imunoistoquímico em coelhos /Figueira Júnior, Heldo Cesar. January 2018 (has links)
Orientador: Idelmo Rangel Garcia Junior / Coorientadora: Roberta Okamoto / Banca: Francisley Ávila Souza / Banca: Leonardo Perez Faverani / Banca: Vilmar Devanir Gottardo / Banca: André Luís da Silva Fabris / Resumo: Tratamentos de superfície de materiais implantáveis no corpo humano são analisados incansavelmente dentro das áreas da saúde. É comum ser observado em artigos científicos o emprego de um recente e desconhecido biomaterial sendo analisado para este fim. O objetivo deste estudo foi avaliar o emprego do alendronato sobre a caracterização topográfica de implantes e discos de titânio in vitro, e sobre a superfície de implantes de titânio inseridos em coelhos após levantamento de seio maxilar, correlacionando as respostas biológicas e físicas do tratamento comparadas a protocolos bem estabelecidos da implantodontia. Utilizou-se seis discos e vinte e seis implantes dentários ambos de titânio comercialmente puro. Para as análises topográficas, discos e implantes se dividiram em 2 grupos de 3 amostras: Grupo CTL, submetidos a subtração ácida e grupo ALD, submetidos a tratamento biomimético com alendronato. Para os testes em animais, 5 implantes foram distribuídos por grupo, CTL e ALD, com intervalos de eutanásia de 7 e 40 dias. Após microscopia eletrônica de varredura, análise de espectroscopia por energia dispersiva, análise do ângulo de contato com a água, de energia livre de superfície e da presença de sítios doares de elétrons (base de Lewis), os grupos ALD apresentaram resposta satisfatória frente aos processos aceitos em saúde, sendo superiores em todas as análises. A resposta histométrica também foi mensurada resultando em maior tecido ósseo nas análises ELCOI e AON nos grupos ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Surface treatments of implantable materials in the human body are analyzed tirelessly within the health areas. It is common to observe in scientific articles the use of a recent and unknown biomaterial being analyzed for this purpose. The objective of this study was to evaluate the use of alendronate on the t opographic c haracterization of implants and titanium discs in vitro, and over the surface of titanium implants inserted into rabbits after maxillary sinus lift, correlating the biological and physical responses of the treatment compared to well established implantology protocols. It was used six disks and twenty - six commercially pure titanium dental implants. For the topographic analyzes, disks and implants were divided into 2 groups of 3 samples: CTL group, submitted to acid subtraction and ALD group, submi tted to biomimetic treatment with alendronate. For the animal tests, 5 implants were distributed per group, CTL and ALD, with euthanasia intervals of 7 and 40 days. After scanning electron microscopy, analysis of energy dispersive spectroscopy, analysis of the water contact angle, free surface energy and the presence of electron ́s donor sites (Lewis base), the ALD groups showed a satisfactory response to the accepted processes in health, being superior in all the analyzes. The histometric response was also measured resulting in increased bone tissue in the ELCOI and AON analyzes in the ALD 40 days' group. The discrete presence of TRAP at 40 days refers to low bo... (Complete abstract click electronic access below) / Doutor
|
363 |
Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré-maxilar variando-se o tamanho do implante e tipo de ancoragem óssea : estudo pelo método dos elementos finitos 3-D /Oliveira, Hiskell Francine Fernandes e. January 2017 (has links)
Orientador: Fellippo Ramos Verri / Banca: Karina Helga Turcio de Carvalho / Banca: Joel Ferreira Santiago Junior / Resumo: Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré - maxilar variando - se o tamanho do implante e tipo de ancoragem óssea. Estudo pelo método dos elementos finitos 3 - D . [Dissertação]. Araçatuba: Faculdade de Odontologia da Universidade Estadual Paulista; 2017. Resumo Este trabalho teve como objetivo analisar a distribuição das tensões em próteses unitárias implantossuportadas de cone morse, em região de maxila anterior, variando o tipo de ancoragem óssea em colocação convencional, bicorticalizado e bicorticalizado com levantamento de assoalho nasal, com diferentes comprimento s do implante, sendo eles de 8,5, 10 e 11,5mm e diâmetro de 4,0 mm, através do método dos elemen tos fin itos tridimensionais. F oram simulados 3 modelos tridimensionais maxilares da região anterior envolvendo o elemento 11, com auxílio de programas de criação de modelos a partir de tomografias, o InVesalius (CTI, São Paulo, Brasil) e programas de desen ho assistido, o Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) e o SolidWorks 2011 (SolidWorks Corp, USA). Os modelos dos blocos ósseos foram reconstruídos a partir da tomografia computadorizada, com a presença de um implante nas dimensões citadas acima, com coroa livres de metal em zircônia e cimentada s. Os modelos 3D foram exportados para o programa de elementos finitos FEMAP v.11 (Siemens Product Lifecycle Management Software Inc.USA) para dis cretização dos modelos, geração da malha de elementos finitos e análise posterior a processamento no programa NEiNastran 11 (Noran Engineering, Inc., USA). Foram aplicadas cargas de 178N, em ângulo de 0º, 30º e 60º, considerando - se o longo eixo do im plante como referência . Os resultados foram visualizados por meio de mapas de deslocamento, tensão de von Mises, tensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the distribution of tensions in morse tapper implants supporting single crowns in the anterior region of maxilla, varying the type of bone anchorage in conventional, bicorticalized and bicorticalized placement with nasal floor elevation, and different lengths of implants (8.5, 10 and 11.5mm) with 4.0 mm of diameter, using the 3D finite element analyses. Three 3-dimensional maxillary models of the anterior region including element #11 were simulated using software InVesalius for CT Scan recomposition (CTI, São Paulo, Brazil) and CAD-software Rhinoceros 3D 4.0 (NURBS Modeling For Windows, USA) and SolidWorks 2011 (SolidWorks Corp, USA). The bone block models were reconstructed from the computed tomography, with the presence of an implant in the dimensions mentioned above, with cemented zirconium metal free crowns. The 3D models were exported to the FEMAP v.11 finite element software (Siemens Product Lifecycle Management Software Inc.) for models discretizadion, mesh generation and post-processing analysis after processing progress in the NEiNastran 11 program (Noran Engineering, Inc ., USA). Loads of 178N were applied at angle of 0º, 30º and 60º, considering the implant long axis as reference. The results were visualized by means of displacement maps, von Mises maps, Max Principal maps and microstrain. Analyzing all stress maps, the bicortical models were the ones that showed with better stress and strain distributions, both in the implant a... (Complete abstract click electronic access below) / Mestre
|
364 |
Análise das intercorrências e complicações interferentes na instalação e perda primária dos implantes dentais osteointegráveis - um estudo retrospectivo / Analysis of intercurrences and complications interfering in the placement and primary loss of osseointegratable dental implants a retrospective studySilva, Alessandro Costa da 09 October 2008 (has links)
Intrinsecamente, todo procedimento cirúrgico apresenta um certo índice de intercorrências e/ou complicações associadas. Hemorragias, infecções, parestesias ou disestesias e perda primária dos implantes são algumas das intercorrências e complicações mais comuns relacionadas a procedimentos cirúrgicos para implantodontia. Este estudo avaliou retrospectivamente o índice de intercorrências e complicações após cirurgia para a instalação de implantes dentais osteointegráveis. Foram avaliados, retrospectivamente, 660 prontuários clínicos de pacientes submetidos à instalação de implantes osteointegráveis no período 8 anos atendidos na Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba - Unicamp. Os resultados demonstraram que houve um maior índice de intercorrências e complicações quando os pacientes eram atendidos por alunos de especialização (p= 0,015) e quando o exame por imagem realizado era somente a radiografia panorâmica convencional (p= 0,011). Os resultados demonstraram também um maior índice de intercorrências e complicações nos pacientes quando estes eram submetidos a procedimentos cirúrgicos de reconstrução óssea alveolar (p< 0,0001). A presença de infecção pós-operatória influenciou significativamente para o aumento no índice de perda primária de implantes (p< 0,0001). / Intrinsically, every surgical procedure presents a certain rate of associated intercurrences and/or complications. Hemorrhages, infections, paresthesias or dysesthesias and primary loss of implants are some of the most common intercurrences and complications related to surgical procedures in implant dentistry. This study conducted a retrospective evaluation of the rate of intercurrences and complications related to patients submitted to osseointegratable dental implant placement. A retrospective evaluation was made of 660 clinical record charts of patients submitted to osseointegratable dental implants in the period of 8 years, attended in the Oral and Maxillofacial Surgery Department of Piracicaba Dental School - Unicamp. The results showed that there was a higher rate of intercurrences and complications when patients were attended by residents (p= 0.015) and when the panoramic radiograph was the only preoperative image exam requested (p= 0.011). The results also showed a higher rate of intercurrences and complications in patients when they were submitted to surgical procedures of alveolar bone reconstruction (p< 0.0001). The presence of post-operative infection had a significant influence on the increase in the primary loss of implants (p< 0.0001).
|
365 |
Avaliação histológica e histomorfométrica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Histologic and histomorphometric evaluation of bone behavior in relation to the depth of the line of marginal cementation on Morse taper implants: experimental study in dogsStancari, Fernanda Herrera 18 May 2015 (has links)
A utilização dos implantes cone morse muito favorece a estética peri-implantar e seu uso em conjunto com próteses cimentadas favorece ainda mais a estabilidade do sistema, simplificando também os procedimentos protéticos. O presente estudo histológico e histomorfométrico utilizou os implantes cone morse com o intuito de avaliar o comportamento tecidual com relação à posição da margem da cimentação protética em relação ao tecido ósseo quando se faz o uso próteses cimentadas. Foram utilizados quatro cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica, na qual foi realizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados vinte e quatro implantes numa profundidade de 3 mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos utilizados foram do tipo munhão universal e apresentavam diferentes alturas transmucosas iguais a 1.5 mm, 3.5 mm, e 5.5 mm. Isto fez com que a margem da cimentação se posicionasse a 1.5 mm infra óssea, a 0.5 mm supra óssea e a 2.5 mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Os animais permaneceram sobre controle de placa durante 10 semanas subsequentes a instalação dos implantes, sendo este o tempo final do experimento através da realização da eutanásia. As amostras foram preparadas para análise histológica e avaliação dos tecidos peri-implantares. A região de interesse foi medida através da distância entre a margem do pilar protético e a porção mais coronal da crista óssea peri-implantar. Foram utilizados os testes estatísticos ANOVA a três critérios com medidas repetidas e teste de Tukey com o nível de significância de p < 0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental (p = 0.2764) e que os pilares de 1.5 mm mostram menos perda óssea comparada aos outros pilares, considerando que a distância média da remodelação óssea foi menor neste grupo (0.6859 mm) comparada com os pilares de 3.5 mm (1.2917 mm) e 5.5 mm (1.0823 mm). Conclui-se que não há influência da profundidade da margem da cimentação protética no comportamento da crista óssea e que a utilização de diferentes alturas dos pilares protéticos não parece alterar o tecido ósseo marginal ao redor dos implantes Cone Morse. / The use of Morse taper implants has increased because of some positive features. Cemented crowns can be extensively used, taking advantage of the system connection stability, also simplifying the prosthetic procedures. The present histological and histomorphometric study used Morse taper implants with the purpose of evaluating bone behavior with respect to the cementation margin position of the prosthetic crown. Four dogs had all premolars extracted at a first surgical procedure. After three months, there was a second surgical procedure with simultaneous installation of implants and abutments, submitted to immediate load. Twenty four implants were installed 3 mm below the bone level and they were equally divided between Control and Experimental groups. The universal post abutments used had three different transmucosal heights, 1.5 mm, 3.5 mm and 5.5 mm. Thus there were implants with the level of the cementation margin positioned 1.5 mm below the bone level, as well as 0.5 mm and 2.5 mm above the bone level. In the Control group, installation of implants and abutments only was performed. In the Experimental group immediately after the placement of implants and abutments alumina cylinders were cemented. The animals were kept on plaque control for 10 weeks after implant placement and then euthanized. Samples were prepared for histological analysis and evaluation of peri-implant tissues. The region of interest was measured by the distance between the prosthetic margin of the abutment to the most coronal peri-implant bone crest. ANOVA test at three criteria with repeated measures and Tukey test with a significance level of p < 0.05 were applied. The results showed no statistically significant differences between Control and Experimental groups (p = 0.2764). The 1.5 mm abutments presented less bone loss compared to all other abutments tested, because the distance average of bone remodelation was shorter in this group (0.6859 mm) compared to the 3.5 mm abutment (1.2917 mm) and the 5.5 mm one (1.0823 mm). Conclusion: There is no influence of the depth of prosthetic marginal cementation on the behavior of bone crest and the use of different transmucosal heights of abutments does not seem to change the marginal bone surrounding morse taper implants.
|
366 |
Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing testMarques, Vinícius Rizzo 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (α=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((α= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.
|
367 |
Análise clínica e de marcadores biológicos no fluido do sulco peri-implantar correlacionando-os à mucosa ceratinizada ao redor de implantes dentários / Clinical and biological markers analysis in peri-implant fluid and correlation with the keratinized mucosa around dental implantsSouza, Andréia Pereira de 10 February 2017 (has links)
Uma faixa adequada de mucosa ceratinizada (MC) é importante para garantir condições mínimas necessárias para o estabelecimento da homeostasia do periodonto de proteção. Frente à infecção bacteriana, os tecidos periodontais e peri-implantares desenvolvem uma resposta imune inflamatória local, resultando na produção e liberação de diversos mediadores inflamatórios que podem ser encontrados no fluido do sulco gengival e peri-implantar. Entretanto, é escassa a literatura acerca dos níveis desses mediadores em sítios peri-implantares considerando a faixa de MC. Assim, o objetivo deste trabalho foi avaliar a associação entre a quantidade e qualidade da MC peri-implantar e parâmetros clínicos e a qualidade da resposta imune através da análise da concentração de mediadores inflamatórios (IL-1, IL-4, IL-6, IL-8, MIP-1, TNF- e VEGF) presentes no fluido peri-implantar humano antes (T1) e depois (T2) da raspagem subgengival, através de imunoensaio. Parâmetros clínicos avaliaram índice de placa (IP), supuração a sondagem (S), profundidade de sondagem (mesial-PSM, centro-PSC e distal-PSD), índice de sangramento (mesial-ISM, centro-ISC e distal-ISD), nível de inserção relativo (NIR), largura (LMC) e espessura (EMC) da MC na face vestibular. Amostras de fluido sulcular foram coletadas e analisadas. Os implantes foram divididos em grupos de acordo com a faixa de MC (G12mm e G2>2mm) e espessura de MC (GA11mm e GB1>1mm; GA21,5mm e GB2>1,5mm). Foram avaliados 20 pacientes (11 homens e 9 mulheres) com idade entre 40 e 80 anos (53,45±10,32), que apresentaram 42 implantes (G1=25 e G2=17). Os resultados clínicos demonstraram diferença estatística significativa apenas entre T1 e T2 dentro do G1 para IP (T1=56% e T2=16%) e ISM (T1=68% e T2=40%). Foi observada diferença estatística entre G1 e G2 apenas para IL-1 em T2 (G1=9,77pg/ml±12,44 e G2=30,13pg/ml±32,29). Intra-grupos, todas as citocinas aumentaram significativamente, mas apenas no G2, demonstrando diferença de reatividade entre grupos. Quanto à espessura da MC (GA1=6 e GB1=36), resultados clínicos revelaram diferença inter-grupos para ISC em T2 (GA1=16,67% e GB1=61,11%) e intra-grupos para IP no GB1 (T1=52,78% e T2=27,78%). Houve aumento significativo no GB1 para todas as citocinas, exceto VEGF, assim como para IL-1 no GA1. Quando a amostra foi redistribuída em GA2=24 e GB2=18, os resultados clínicos indicaram diferença estatística inter-grupos para PSC em T2 (GA2=2,58mm±1,06 e GB2=3,11mm±1,02) e intra-grupos para IP (T1=62,5% e T2=20,83%) e PSC (T1=2,92mm±1,18 e T2=2,58mm±1,06) no GA2 e para ISM (T1=55,56% e T2=27,78%) no GB2. Intra-grupos observou-se aumento significativo para todas as citocinas no GA2 exceto VEGF, assim como IL-8 no GB2. Conclui-se que as diferenças clínicas apresentadas tenderam a evidenciar a importância da MC principalmente após o preparo inicial e, além disso, uma faixa de MC maior que 2mm influenciou os níveis dos mediadores inflamatórios avaliados após a raspagem subgengival. Adicionalmente, a falta de diferença estatística significativa na comparação entre grupos com diferentes espessuras de MC, bem como tal diferença ora no grupo espesso ora no grupo fino quando se adotam diferentes valores de corte (1mm ou 1,5mm respectivamente), demonstra resultados inconclusivos, ressaltando a importância de novas pesquisas para responder esta questão. / An adequate keratinized mucosa (KM) width is important to ensure minimal conditions necessary to establish protect periodontium homeostasis. When a bacterial infection occurs, periodontal and peri-implant tissues develop a local inflammatory immune response that results in production and release of several inflammatory mediators that may be found in gingival crevicular and in peri-implant fluids. However, there is a lack of literature concerning about the levels of these mediators in peri-implant sites considering KM width. The aim of this study was to evaluate the association between KM peri-implant quantity and quality and clinical parameters and immune response quality by analyzing the inflammatory mediators concentration (IL-1, IL-4, IL-6, IL-8, MIP-1, TNF- and VEGF) present in human peri-implant fluid before (T1) and after (T2) subgingival scaling, by immunoassay. Clinical parameters evaluated plate index (PI), probing suppuration (S), probing depth (mesial-PDM, center-PDC and distal-PDD), bleeding index (mesial-BIM, center-BIC and distal-BID), relative attachment level (RAL), keratinized mucosa width (KMW) and thickness (KMT) on the buccal face. Sulcular fluid samples were collected and analyzed. The implants were divided in groups according KM width (G12mm and G2>2mm) and KM thickness (GA11mm and GB1>1mm, GA21,5mm and GB2>1,5mm). Twenty patients (11 men and 9 women) aged 40 to 80 years (53,45±10,32) were evaluated, with 42 implants (G1=25 and G2=17). Clinical results showed a significant statistical difference only between T1 and T2 within G1 for PI (T1=56% and T2=16%) and BIM (T1=68% and T2=40%). Statistical difference was observed between G1 and G2 only for IL-1 in T2 (G1=9,77pg/ml±12,44 and G2=30,13pg/ml±32,29). Intra-groups, all cytokines increased significantly, but only in G2, showing reactivity difference between groups. As to KM thickness (GA1=6 and GB1=36), clinical results revealed intergroup differences for BIC in T2 (GA1=16,67% and GB1=61,11%) and intra-groups for PI in GB1 (T1=52,78% and T2=27,78%). There was a significant increase in GB1 for all cytokines except VEGF, as well as for IL-1 in GA1. When the sample was redistributed in GA2=24 and GB2=18, clinical results indicated statistical inter-group differences for PDC in T2 (GA2=2,58mm±1,06 and GB2=3,11mm±1,02) and intra-groups for PI (T1=62,5% and T2=20,83%) and PDC (T1=2,92mm±1,18 and T2=2,58mm±1,06) in GA2 and for BIM (T1=55,56% and T2=27,78%) in GB2. Intra-groups were observed significantly increase for all cytokines in GA2 except VEGF, as well as IL-8 in GB2. Concluded that clinical differences presented tended to show the KM importance principally after the initial preparation and, in addition, KM width greater than 2mm influenced the inflammatory mediators levels evaluated after subgingival scaling. Additionally, the absence of significant statistic difference between groups when comparing the keratinized mucosa thickness, as well as this difference sometimes in the thick group or in the thin group when different court values was adopted (1mm or 1,5mm respectively), show inconclusive results, emphasizing the importance of new research that may answer this question.
|
368 |
Análise histomorfométrica de implantes hidrofóbicos e hidrofílicos: estudo experimental em coelhos / Comparative histomorphometric analysis of hydrophobic and hydrophilic implants: an experimental study in rabbitsCunha, Verena Souza da 03 June 2015 (has links)
O íntimo contato entre osso e implante é considerado um pré-requisito fundamental para o sucesso dos implantes dentários, condição esta conhecida como osseointegração. Devido a isto, um grande número de pesquisas com tratamentos de superfícies de implantes vem sendo desenvolvido por várias empresas nos últimos anos, visando acelerar esse fenômeno. O objetivo deste trabalho é avaliar histomorfometricamente o percentual de contato osso-implante (BIC) e área de osso novo (BA) entre implantes de tratamento de superfície Neoporos (GC - hidrofóbico) e implantes com energia de superfície molhada Acqua (GE - hidrofílicos). Foram utilizados 15 coelhos da raça new zealand, que receberam 30 implantes divididos em cada lado de suas tíbias direita e esquerda, ambos de titânio comercialmente puro grau IV com 3.5x8mm de dimensão, sendo ao final de 15 dias, a região dos implantes coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados, embora dois implantes do grupo Esm tenham sido excluídos da pesquisa devido à instalação ter ocorrido dentro do canal medular e terem obtido tecido necrosado, não cumprindo as características de osseointegração. Para análise dos dados estatísticos, utilizou-se o teste t de Students para amostras independents e teste Mann-Whitney Rank Sum com nível de significância de p<0.05. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos para a análise de BIC. O grupo GC apresentou a média de 42.9% de BIC, ligeiramente menor que o grupo GE, que apresentou 49.3% de média. Já para o teste BA houve diferenças de 15%, em que o grupo GC apresentou 58.6% e o grupo GE, 74.4%. A conclusão é que há, ainda, necessidade de maiores estudos a cerca do referido tema. / The near contact between bone and implant is considered an essential pre-requisite for the success of dental implants, a condition known as osseointegration. Due to it, a great amount of researches on implants surface treatments has been developed by several companies in recent years to accelerate the phenomenon of osseointegration. The aim of the present study is to evaluate histomorphometrically the percentage of bone-implants contact (BIC) and the area of new bone (BA) between implants with surfaces treatment Neoporos (GC - hydrophobic) and implants with wets surface energy Acqua (GE - hydrophilic). It was used fifteen (n=15) New Zealand rabbits, which received thirty implants installed dividing them between its right and left tibias. Implants were commercially pure titanium grade IV with 3.5x8mm dimension. After fifteen days, the implants area were collected and processed histologically in order to obtain not demineralized tissue sections. For statistical data analysis, it was used the t test for independents samples and Mann-Whitney Rank Sum test. The significance level was p<0.05. Results showed no statistical significant difference between groups for BIC analysis. The control group showed a mean of 42.9% of BIC, slightly lower than the GE group, which showed a mean of 49.3%. For BA test, there was a significant difference of more than 15% in the control group (58.6% for the GC group and 74.4% for GE group). It was concluded that futher studies is needed on this topic of osseointegration and hydrophobic /hydrophilic implants.
|
369 |
Alterações dimensionais mandibulares e sua relação com atividade muscular em pacientes portadores de próteses implantossuportadas / Mandibular dimensional changes and its relationship with muscular activity in pacients when implant-supported prosthesis are usedMandelli, Tânia Mara de Tassis 07 November 2008 (has links)
Objetivos: este estudo se propôs avaliar a correlação entre atividade do músculo masseter e alteração óssea mandibular, posterior ao último implante, um ano após a reabilitação com próteses implantossuportadas, em pacientes com fissura labiopalatina já reparada. Material e Método: As alterações dimensionais ósseas foram medidas em radiografias panorâmicas digitalizadas realizadas antes e um ano após a reabilitação de dezessete pacientes. A eletromiografia dos músculos masseteres foi realizada durante a contração voluntária isométrica máxima (CVIM) por 5s, mastigação habitual de cenoura (MH), mastigação unilateral direita (MUD) e esquerda (MUE) de látex. Resultados: ocorreu aumento ósseo significativo na mandíbula de 1,98mm (p<0,001) para o tipo de prótese inferior overdenture implantossuportada. O lado direito é maior que o esquerdo em 0,9mm. Um significante aumento da amplitude para a MH (9V) e para a MUE (19V) foi observado, independente do tipo de prótese. Um aumento significante para a MUE (19V) foi observado para a prótese overdenture. Ocorreu um aumento estatisticamente significante para o ato mastigatório durante os três tipos de mastigação (MH=0,13s, MUD=0,06s, MUE=0,12s), independente do tipo de prótese. Para o ciclo mastigatório também foi observado aumento estatisticamente significante, independente do tipo de prótese durante a MH (0,12s) e MUE (0,11s). Conclusão: Ocorreu aposição óssea na região posterior da mandíbula para a prótese overdenture e apesar do aumento da atividade muscular, não foi encontrada correlação estatisticamente significante com a atividade muscular do masseter. / Purpose: The purpose of the present study was to evaluate the correlation between masseter muscle activity and changes occurred in mandibular bone height, posterior to the last implant, one year after implant-supported prosthesis rehabilitation in repared cleft lip and palate patients. Materials and Methods: changes in mandibular bone height were measured in digitalized images of panoramic radiographies taken before and one year after oral rehabilitation of seventeen repared cleft lip and palate patients (Radiocef 2 Radiomemory). Parameters for electromyography of masseter muscle were: maximum voluntary isometric clench (MVC) for 5s, habitual chewing of carrots (HC) and unilateral right (URL) and left (ULL) chewing of latex. Results: a mean increase in mandibular bone height of 1,98mm (p<0,001) for the implant retained overdenture was observed. Bone apposition was higher in the right side. Significant increase in the amplitude was observed during HC (9V) and during ULL (19 V), regardless prosthesis type and side. A significant increase was observed during URL (19 V) for the implant retained overdenture. A significant statistical increase for the masticatory act was observed during the three types of mastication (HC=0,13s, URL=0,06s, ULL=0,12s), regardless prosthesis types. A significant statistical increase was observed for the masticatory cycle during HC (0,12s) and ULL (0,11s), regardless prosthesis type. Conclusion: Mandibular bone apposition in the posterior region to the last implant, in patients using implant retained overdentures and improvement in muscular activity in both types of prosthesis were observed, although no significant correlations were encountered between them.
|
370 |
Avaliação da resistência e módulo de elasticidade de osso mineralizado e desmineralizado pelos testes de microtração / Evaluation of the resistance and modulus of elasticity of bone mineralized and desmineralized for the tests of microtensileSanada, Jefferson Tomio 28 March 2007 (has links)
A perda do osso alveolar como resultado de doença periodontal ou secundariamente à cirurgia são fontes de inúmeras complicações para os cirurgiões dentistas, e a solução para tal problema se baseiam em procedimentos regenerativos. A regeneração é feita através de enxertos ósseos que estabelecem um arcabouço para a reparação tecidual, aumentando os tecidos ósseos nos defeitos resultantes de trauma ou cirurgias, preenchendo os alvéolos após extração para preservar a altura e espessura do rebordo alveolar e aumentando e/ou reconstruindo o rebordo alveolar. Estes procedimentos são realizados através da utilização de enxertos autógenos, alógenos, aloplásticos ou xenogênicos, tendo cada um suas características e indicações. Com o desenvolvimento dos implantes osseointegrados, viu-se a necessidade de manter uma boa quantidade e qualidade óssea. Este projeto tem como objetivo avaliar a resistência a tração e módulo de elasticidade do osso mineralizado e desmineralizado de calvária de ratos, a fim de determinar padrões iniciais (máximos e mínimos) para comparações com possíveis biomateriais de preenchimento de osteoindução e osteocondução. Foram utilizados 24 animais divididos em 2 grupos. O grupo 1 (n=12): módulo de elasticidade sendo que utilizaremos as duas parietais do animal, possibilitando 24 espécimes, subdividido em mineralizado (n=12) e desmineralizado (n=12). O grupo 2 (n=12): microtração, sendo que 12 hemicalvária foram utilizado para o sub-grupo desmineralizado e as outras 12 hemicalvária para o sub-grupo mineralizado. Após a morte dos animais, os espécimes serão coletados e tratados de acordo com o subgrupo (mineralizado e desmineralizado). Os testes foram realizados numa máquina de teste universal (Vitrodyme, V1000). As médias de resistência a tração do mineralizado foi 129,814 ± 34,921 MPa e o desmineralizado foi 18,547 ± 3,682 MPa. Para o módulo de elasticidade obtivemos os valores de 1377,792 ± 208,331 MPa para o grupo mineralizado e 49,669 ± 11,204 MPa para o grupo desmineralizado, ao compararmos o módulo de elasticidade e resistência a tração entre os subgrupo desmineralizado e mineralizado observa-se uma diferença estatisticamente significante para o grupo mineralizado (p<0,001). Conclui-se que o teste de microtração pode ser utilizado para avaliar as propriedades mecânicas nesse modelo experimental biológico. / The loss of the alveolar bone as resulted of periodontal illness or second to the surgery is sources of innumerable complications for the surgeons dentists, and the solution for such problem if it bases on regenerative procedures. Regeneration is made through bone grafts that establish one scaffold for the tecidual repairing, increasing bone fabrics in the resultant defects of trauma or surgeries, filling the alveolous after extraction to preserve the height and thickness of the alveolar rigde and being increased and/or reconstructing the alveolar rigde. These procedures are carried through the use of autogenous, alografts, aloplastic or xenogenics grafts, having each one its characteristics and indications. With the development of the osseointegrated implants, it was seen necessity to keep a good amount and bone quality. This project has as objective to evaluate the resistance the traction and modulus of elasticity of the mineralized bone and desmineralized.of calvarium of rats, similar to determine initial standards (maximum and minimum) for comparisons with possible biomateriais of fulfilling of osteoinduction and osteoconduction. 24 animals divided in 2 groups had been used. Group 1 (n=12): modulus of elasticity being that we will use the two parietals of the animal, having made possible 24 specimens, subdivided in mineralized (n=12) and desmineralized (n=12). Group 2 (n=12): microtraction, being that 12 hemi-calvarium had been used for 12 the desmineralized sub-group and the others hemi-calvarium for the mineralized sub-group. After the death of the animals, the specimens will be collected and treated in accordance with the sub-group (mineralized and desmineralized). The tests had been carried through in a machine of universal test (Vitrodyme, V1000). The resistance averages the traction of the mineralized one was mineralized 129,814 ± 34.921 MPa and the desmineralized one was 18,547 ± 3,682 MPa. For the modulus of elasticity we got values of 1377,792 ± 208.331 MPa for the mineralized group and 49,669 ± 11,204 MPa for the desmineralized group, when comparing the resistance and modulus of elasticity the traction between the desmineralized and mineralized sub-group observes a estatistical significant difference for the mineralized group (p<0,001). Concluded that the microtraction test can be used to evaluate the mechanical properties in this biological experimental model.
|
Page generated in 0.0771 seconds