• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 27
  • 9
  • Tagged with
  • 72
  • 72
  • 39
  • 29
  • 26
  • 21
  • 15
  • 13
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Dagens inneklimat : En granskning av svenska riktlinjer för rådande inneklimat / Indoor climate today : A review of the Swedish guidelines for the prevailing indoor climate

Benitez, Miguel, Goyeryd, Adam January 2015 (has links)
I dag pratas det mycket om hur viktigt det är med ett bra och hälsosamt inneklimat. För att människor ska trivas och arbeta effektivt behöver arbetsplatsen ha ett bra inomhusklimat. Eftersom människan spenderar största delen av sitt liv inomhus är det viktigt att inte påverkas negativt av den inre miljön. Byggnadens huvudsyften är att skydda människor men många byggnader orsakar hälsoproblem av olika slag. Det finns mycket liten vetskap om vad ett bra inneklimat verkligen innebär. Detta kan till exempel orsaka kommunikationsproblem som försvårar förhandling då kunden och företaget tolkar varandras åsikter om inneklimat olika. Syftet med examensarbetet är att underlätta förhandlingsprocessen genom att definiera innebörden av inneklimat samt beteckningar som vanligen används. Detta ska hjälpa både kunden och företaget att förstå vad kraven och riktlinjerna betyder genom att utgå från gemensamma definitioner och förutsättningar. Arbetet har utförts utifrån allmänna definitioner av inneklimatfaktorer samt beskrivningar av riktlinjer. Problematiken, som uppstår vid överenskommelse med kunder på grund av saknande av information, har identifierats i samtal med experter. Definitionerna och beskrivningar som tagits fram i rapporten kommer att användas för att hjälpa till under förhandlingar och underlätta kommunikationen mellan beställare och utförare. Arbetet har lett till några slutsatser som är värda att tänka på: Bristen på kunskap kan försvåra förhandlingar, därför är det viktigt att informationen förmedlas på ett tydligt och pedagogisk sätt. Riktlinjerna är där som stöd vid projektering eller bedömning, men de bör behandlas med viss försiktighet på grund av den begränsade uppdateringen av dessa. / An actual question is the importance of having a good and healthy indoor climate. The workplace need to have a good indoor climate, so that people can thrive and work effectively. Since people spend most of thier lives indoors, it is important to avoid being negatively affected by the internal environment. Buildings have the main purpose to protect people but many buildings cause health problems of various kinds.  There is a poor knowledge of what a good indoor climate really mean is. This can, for example, cause communication problems that complicate the negotiation where the customer and the company have different concepts of what indoor climate is. The purpose of this project is to ease the negotiation process by defining the meaning of the indoor climate and commonly used terms. This will help the customer and the company to understand the meaning of requirements and guidelines by starting from common definitions and conditions. This project has been written based on general definitions of the factors that affect the indoor climate as well as descriptions of the guidelines. The problem that emerges in agreement with the customers, because of lacking information, has been identified in discussions with experts. Definitions and descriptions contained in this essay will be used to assist during the negotiations and ease the communication between the client and contractor. The project has led to some conclusions that are worth thinking about: The lack of knowledge can aggravate negotiations; therefore it is important that the information is mediated in a clear and educational way. The guidelines are there to assist the planning or assessment, but they should be treated with caution because of the limited update of these.
22

Utvärdering av VAV i nybyggt kontorshus / Evaluation of VAV in newly constructed office building

Innergård, Sofia January 2011 (has links)
VAV (Variable Air Volume) system has been studied in a newly constructed office-building. The goal for the study has been to evaluate how the ventilations system work in practice, if adjustments can be made to achieve an more energy efficient system and to evaluate if other alternative ventilation systems is to be preferred in the further. The degree project has been executed at Helenius Engineering Firm who is working with the environment, media systems, HVAC and energy in buildings. The building that has been studied is owned and operated by Akademiska hus. Literature studies, visits at site, inventory, review of system documentation, energy analyses, interviews, key figures, LCC, sand energy- and indoor climate simulations has been made to study the building. Where appropriate some tools from Six Sigma have also been used. How to achieve an energy efficient system and a pleasant indoor climate is studied with human health and well-being as base for the indoor climate requirements. Technical support systems such as ventilation systems have to be designed so that an acceptable indoor climate can be achieved. The building itself along with the type of activity create prerequisites and limitations in regards to how energy efficient the system can be. In the two first visits which were conducted in the start of the project it appeared that the ventilation system were not functioning as expected. In a later visit, some of the issues were solved and in a recent meeting between Akademiska hus and the tenants, the tenants seemed pleased with the indoor climate. Analyses of service requests statistics, interviews together with cause and effect analyses has revealed that there has been issues with the indoor air quality ant that the rooms has been perceived as to warm or too cold. Some of the causes has been loose sensor cables, reduction of the temperature in the room during absence from people during winter time and short circuit between intake of outdoor air and the outlet of exhaust air on the roof. The building has a low energy consumption compared to key figures presented by Repab. Energy and indoor climate for alternative temperature settings has been simulated in the program IDA and shows that the energy consumption can be reduced. The interviews give a picture that VAV systems are preferred when they are well functioning. But VAV systems have disadvantages such as they are complex and require good knowledge and understanding about the control system from all people concerned. Many components and functions give more opportunities for failures. In comparison with other ventilations systems, VAV according to cost estimates and LCC are the most cost effective ventilations system for offices. / VAV (Variable Air Volume) system har studerats i en nybyggd kontorsfastighet. Målet med arbetet var att ta reda på hur ventilationssystemet fungerar i praktiken, om justeringar kan göras för att uppnå ett mer energieffektivt system samt att utvärdera om alternativa ventilationssystem är att föredra i framtiden. Examensarbetet är utfört hos Helenius Ingenjörsbyrå som arbetar med konsulttjänster inom miljö, mediesystem, VVS och energi. Huset som har studerats ägs och förvaltas av Akademiska hus. Huset har studerats med stöd av litteraturstudier, genom platsbesök, inventering och genomgång av befintlig systemdokumentation, energianalyser, intervjuer med berörda personer, nyckeltalsanalyser, LCC kalkyler samt genom simuleringar i energi- och klimatsimuleringsprogrammet IDA ICE 4. Verktyg från Sex Sigma metodiken har även använts där det har varit lämpligt. Hur ett energieffektivt system och ett behagligt inneklimat kan uppnås har studerats där utgångspunkten är människans hälsa och välbefinnande påverkar krav för inneklimat. Tekniska supportsystem så som ventilationsanläggningar måste vara designade och byggda på ett sådant sätt att ett önskvärt inneklimat kan uppnås. Byggnaden och verksamheten skapar förutsättningar och begränsningar med avseende på energieffektivitet. Vid de två första platsbesöken och intervjuerna som skedde tidigt i arbetet framkom det att ventilationssystem inte har fungerat bra, den bilden förändrades vid uppföljande besök i slutet av arbetet. Direkta fel var då åtgärdade eller arbete pågick och under det senaste mötet Akademiska hus hade med hyresgästerna uppgav de att de var nöjda med inneklimatet. Analys av felanmälningsstatistik, intervjuer tillsammans med orsaksanalys har visat att det framförallt varit problem med kvalitén på luften i rummen samt att rummen uppfattats som varma eller kalla. Några av grundorsakerna har varit att kablar lossnat till givare, frånvarotemperatur under vinterhalvåret, samt kortslutning av avluft och intag av uteluft på taket. Huset har enligt jämförelser med riktvärden från Repab en låg energiförbrukning. Alternativa inställningar av temperaturer har genom simuleringar av energi och inneklimat i programvaran IDA visat att energiförbrukningen kan reduceras. Intervjuer ger en bild av att VAV system är att föredra om de fungerar väl. Nackdelar som finns med VAV system är att de är komplexa, kräver god kunskap och förståelse av systemets styrning från alla berörda samt att de innehåller många komponenter och funktioner vilket medför att det finns många felkällor. I jämförelse med andra system, är VAV systemet enligt de kostnadsuppskattningar och LCC beräkningar som gjorts, det mest kostnadseffektiva ventilationssystemet.
23

Thermal comfort study on a renovated residential apartment in Tjärna Ängar, Borlänge

Mnla Ali, Tammam January 2021 (has links)
The Swedish government in the 1960th initiated “The Million Program” to build million residentialunits to cover the housing shortage between 1965 to 1975. Tjärna Ängar neighborhood in Borlängemunicipality was built during the million-program period, where these residential units became old,and the indoor environment is uncomfortable for the residents.Recently, there have been extensive energy-efficient renovations to improving the energyefficiency,indoor air quality, and thermal comfort of these buildings. The renovation project, withcooperation between Dalarna University and the local housing company (Stora Tunabyggen)started in 2015 by renovating three buildings in the Tjärna Ängar neighborhood.This study was conducted at one of these three retrofitting buildings (Kornstigen 25) to investigatethe thermal comfort in the building following energy retrofit. The assessment of the thermalcomfort in this study is based on Fanger's model with the use of predicted mean vote (PMV) andpredicted percentage of dissatisfied (PPD) to assess the obtained measurements.An online questionnaire survey with building occupants was conducted to give a betterunderstanding of the current situation of the retrofitting building before and after the renovationregarding thermal comfort. Based on the measurement, the thermal sensation of the occupants isslightly cool according to the standard’s sensation scale during the period of the measurement. Anonline questionnaire survey assures that the occupants were feeling slightly cool during someperiods of the day inside the apartments.
24

Studying building behaviors by using the Building Management System of a new teaching building : A study case of a school building in Stockholm

Zhang, Kaiying January 2020 (has links)
Building management system (BMS) offers a wide range of measurements and historical data about the building but few types of researches use these data to analyze the building performance. This study aims to explore the indoor climate and building insulation by taking advantage of the BMS of the study case, which 767 sensors are installed in the room and wall structures and the signal data are available at the online web application. In addition, during the inspection, several error sensors and meters are detected are discussed as feedback for the system. It is concluded that the building management system is a good tool to study the building performance in different aspects and the measurements from the sensors are helpful but need validation by conducting a further field measurement in the building.
25

Utvärdering av inomhusklimat och produktivitet – från etablerad praxis till innovativa metoder / Assessing Indoor Climate and Occupant Productivity – From Established Practice to Innovative Approaches

Vrettos, Konstantinos January 2017 (has links)
As societies evolve, offices have become the places were the majority of working activities take place. Occupants’ comfort in office buildings has always been a very important issue in the building sector and therefore guidelines regarding indoor comfort standards have been developed throughout the years. Nevertheless, there is a need for investments on new and innovative ideas which will go beyond the existing guidelines and move towards a more sustainable and human oriented office environment.The present thesis aims at promoting this idea of sustainable offices by developing and presenting an innovative technological method which will provide the opportunity to measure the office workers’ perceived comfort in real time. This in its turn will enable the building sector stakeholders to operate office buildings in a more sustainable way in terms of building services provision to their occupants.In order to achieve these objectives, the first part of the thesis is dedicated in describing the basic indoor environmental components of the office environment as well as the possible associations between improved indoor environmental quality and occupants’ health, wellbeing and productivity. The second part aims to provide a detailed presentation of the existing or emerging methods which are currently used in order to predict or directly measure occupants’ perceived comfort in office places while in the same time discussing their current capabilities and limitations. In the final part, our proposed method, which could be used for the purposes of real time perceived comfort measurements, is presented. This proposed method includes four different steps which are separately presented with detailed instructions regarding their proper implementation.
26

Hur kan en skola med högre energianvändning än det svenska genomsnittet energieffektiviseras? : Energikartläggning

Andersson, David, Olsson, Philip January 2017 (has links)
Europeiska unionen som helhet är en av de största energianvändarna och har en av världens största utsläpp av växthusgaser. För att minska globala uppvärmningen har mål sats upp för att medeltemperaturen på jorden inte ska öka mer än 2 grader sen förindustrielltid. Närmare 40 % av Sveriges totala energianvändning kommer från bostads- och servicesektorn detta i samband med att 2020-målen närmar sig bidrar till att energieffektiviseringar i byggnader blir allt mer essentiellt. Energikartläggningar är ett verktyg för att bestämma vad som har stört energibesparingspotential innan effektiviseringsåtgärder sker. Examensarbetet inkluderar en energikartläggning av Trödje skola som förvaltas av Gavlefastigheter. Arbetet är utfört med simuleringsverktyget IDA Indoor Climate and Energy. IDA ICE användes för att modulera den befintliga byggnaden där all data för skolan inkluderades. Rapportens vision är att undersöka hur mycket energi som är möjlig att spara genom energibesparingsåtgärder samt vilken åtgärd som är effektivast. Energibesparingspotentialen i skolan är hög, skolan använder 42,6 kWh/m2år mer än genomsnittet för Gavlefastigheters skolor vilket motsvarar 21 %. Resultaten visar att skolans komplexitet samt att påbyggnationen även kallad paviljongen är en stor faktor till att energianvändningen är hög. Skolans energianvändning har en potential att minska med 17 % vilket inte motsvarade det uppsatta 25 % - målet med arbetet. Arbetet visar att störst besparingspotential finns via byte av fönster och värmeväxlare i ventilationssystemet men även att de åtgärder som antas ge störst besparing inte alltid är effektivast. / The European Union as a whole is one of the largest energy users and has one of the world's largest greenhouse gas emissions. To reduce global warming, targets have been set to ensure that the average temperature on the earth does not increase more than 2 degrees since the pre-industrial time. Nearly 40% of Sweden's total energy use comes from the building and services sector which in context with that the 2020 targets approaching contributes to the increased need of higher energy efficiency of buildings. Energy audits is a tool for determining what has the greatest potential for saving energy before efficiency measures occurs. The thesis includes an energy audit of Trödje primary and middle school, administered by Gavlefastigheter. The study was performed using IDA Indoor Climate and Energy simulation tool. IDA ICE was used to modulate the existing building where all data for the school was included. The vision of the thesis is to investigate how much energy which is possible to save through energy saving measures and which action that is most effective. The potential energy saving in the school is high, the school uses 42.6 kWh/m2year more than the average for Gavlefastigheter schools, which corresponds to 21 %. The results show that the complexity of the school and the reconstruction, also called the paviljong, are a major factor in the high energy consumption. The school's energy use has a potential to decrease by 17 %, which did not correspond to the 25 % target set for the work. The work shows that the greatest savings potential exists through the exchange of windows and heat exchangers in the ventilation system, but also that the measures that are assumed to give the greatest savings are not always the most effective.
27

Interakce architektury a geomagnetického pole / Interaction of architecture with geomagnetic field

Holá, Magda Unknown Date (has links)
With the application of new technological trends and principles of scientific research in general, places on environmental influences (everything what surrounds human - building interior and exterior materials, urban areas) and also with sustainable development and ecology, etc., and on health and psychological well-being humans and thus puts on architecture and building entirely new demands on the application of new principles. Due to global climate change, which recently published the official report of the International Panel on Climate Change (IPCC), are placed on reducing the emissions into the atmosphere greater demands on. If architects previously were requested by the client, building with optimal solutions and functional expression of aesthetic quality, so now in addition to increasing demand on building´s solution with low power consumption using environmentally friendly materials from renewable resources and completely satisfying idea of sustainable development. Global societal trends is reverting to the traditional approaches to creating an environment (the application of natural materials, Feng Shui, Building Biology, etc.). The growing trend in today's society on issues of sustainable development, conservation of natural conditions, examining the effects of construction on human health and psychological well-being, which the aims bring together experts seemingly unrelated fields such as geophysics, medicine, architecture, civil engineering, etc., and their findings, according to aspects of the disciplines draw general rules of healthy living. Emerging and still evolving field aims to examine the relationship between man and his environment. The logical starting point is therefore in the context of examining the structure of the first dwelling. Buildings where people spend at least one third of their life. Building, whose location, orientation, mass, materials used in building itself as well as those that surround people in the interior, and many others will affect the physical and physiological action. Not only health but also mental well-being of man is as much determined by a whole range of relationships and linkages. Structural system guidelines for healthy living is the main reason of the work, clear what assumptions we have taken into account in the design and how it specifically relates to a quality place to rest – the Geomagnetic field is one of the base point, which lead to healthy living. Interaction of architecture and geomagnetic field and their values are processed in the evaluation system. It would lead to clarification of the relationship between the occurrence of these anomalies and building materials, construction, site selection for construction of buildings and other solutions. I will desribing the relationship between human´s health and the incidence of these artificial or natural anomalies at the same time.
28

Energieffektivisering av Lokverkstaden i Gamla Motala Verkstad : Uppvärmnings- och Ventilationssystem

Niyonkuru, Prosper, Mugisho, Marc January 2016 (has links)
Nästan alla forskningar om klimatförändringar påpekar att de accelererande klimatförändringarna vi ser till stor del orsakas av mänskliga verksamheter. Om vi inte reducerar energianvändningen kommer våra utsläpp av växthusgaser öka kraftigt och det kan leda till en katastrof i framtiden. För att vi ska klara morgondagen måste vi omedelbart börja begränsa vår energiförbrukning. I Sverige har regeringen som mål att minska energiförbrukningen med cirka 20 % från 1995 till 2020 och 50 % till 2050. Nästan 40 % av all energianvändning förekommer i byggnads- och fastighetssektorn.  För att minska energianvändningen i den sektorn måste vi energieffektivisera även våra befintliga byggnader.  En stor del av energianvändningen går till att täcka transmissionsförluster genom väggar, fönster och köldbryggor. Genom att välja fönster med låg värmeöverföring och rätt isolering till byggnader samt minska transmissionsförlusterna i ventilation och uppvärmning skulle mycket energi kunna sparas. Har en byggnad låg transmissionsförlust reduceras energibehovet markant.  Genom att installera ventilationssystem med en värmeåtervinning (FTX) kan energiförbrukningen avseende förvärmd ventilation minskas kraftigt. Ventilation med värmeåtervinning gör det möjligt att återvinna energi från den utgående luften från lokalerna till den kalla uteluften som ska till lokalerna för att uppehålla en god inomhusmiljö, värmeväxlare har verkningsgrad upp till 0,85. För att energiförbättra gamla byggnader till energieffektiva, krävs nya installationer och ombyggnader för att anpassa till miljövänliga byggnader. Det kan ibland vara svårt att installera FTX-system i befintliga byggnader eftersom luftbehandlingsaggregat kräver stor plats. Den ekonomiska avskrivningstiden är lång. I det här examenarbetet kommer ventilations- och uppvärmningssystem att utredas; fokus ligger på installationsteknik samt energieffektivisering beroende på hur lokalen ska användas. Målet är att undersöka hur stort energibehov en byggnad har samt ge förslag till vilket ventilationssystem som passar byggnaden. Med hjälp av ritningar över Lokverkstaden och diverse information om lokalen skapades en modell i simuleringsprogrammet IDA ICE, en av de bästa simuleringsprogramvaror för energibehov i byggnader. När man hade fått fram en modell att jobba med började inmatningar och utfördes förändringar på byggnaden som motsvarar (med hjälp av) det indata man hade fått från beställaren. Ventilationsritningar utfördes i Magi Cad och en luftbehandling har dimensionerats på Swegons hemsida. Temperaturen i lokalen påverkas av olika faktorer såsom dålig isolering m.m. Lokalerna står i dag helt kalla men lokal uppvärmning förekommer vid extrem kyla för att hålla en del VVS så varmt att det inte fryser. Lokalerna har en stor fuktbelastning och en del av golvet består av en mycket tjock betongplatta. Resultatet visar att det bästa ventilationsaggregat som behövs för att klara av luftflödet på 11,6 m3/s, bör ha specifika fläkteffekten på 2,39 kW/(m3/s). Byggnadens energiförbrukning blev 610624 kWh om året i simuleringen. / Almost all research about climate change points to that the accelerating climate changes we see today, is to a large part caused by human activity. If we don’t reduce our energy usage, our emissions of greenhouse gases will increase heavily - which can lead to disasters in the future. To be able to solve potential problems and avoid disasters in the future, we have to start decreasing our energy usage immediately. In Sweden, the government has the goal of decreasing energy usage with about 20 % from 1995 to 2020, and 50% by 2050. Almost 40% of all energy usage is from the construction and property sector. However, to decrease energy usage within that sector we have to make current buildings more energy efficient. A major part of energy usage in the constructions sector goes to cover transmission losses through walls, windows, and thermal bridges.  So, by choosing windows with low heat transfer and the correct isolation for the specific buildings, as well as, decreasing transmission losses through ventilation and heating would result in that a lot of energy can be saved. If a building has a low transmissions lose, the demand of energy would decrease remarkably. By installing ventilations systems with the function of heat recovery (FTX) so could the energy usage regarding preheated ventilation decrease heavily. While, the ventilation and heat recovery makes it possible to reuse energy from the outgoing air from the facilities to the cold air outside that shall be used in the facilities to maintain a good indoor environment; heat exchangers have an efficiency level of 0.85. To make old buildings energy efficient, it requires new installations and remodeling to adjust them to become environment friendly buildings. It can sometimes be hard to install FTX-systems in current buildings since air-handling units requires a lot of space, and that the financial write-off periods can be long. This thesis will investigate the ventilations- and preheating systems with a focus in installation technics and energy efficiency depending on how the facility will be used. The goals are to investigate how large the demand for energy is in a building, as well as, give suggestions to which ventilations systems that would fit best with the prospective building.   With drawings of a locomotive workshop and miscellaneous information about the facility, and a model of the facility by the simulation program IDA ICE the energy demand in the building was simulated. When a model had been created the work with inputs and changes were made on the buildings - with help from input that has been receive from the client. Drawings of the ventilation were performed in Magi Cad and an air handling has been dimensioned on Swegon’s website. The temperature in the facility is affected by several factors, such as poor isolation etc. The facilities are not heated today besides through local heating at extreme low temperature to maintain a sufficient heat to not freeze the HVAC. The facilities have high moisture level, and at the same time some parts of the floor are made of very thick concrete plates. The results of the tests show that the best ventilation unit that is needed to manage the air flow of 11.6 (m3/s) should have the specific fan power of 2. 39 kW/ (m3/s). The buildings energy use became 610624 kWh/year in the simulation. / <p>Vi redovisade i september 2015 men blev hel godkänd nyligen. Jag visst inte om jag vilket år som gäller(2015 eller 2016)</p>
29

Energieffektivisering av byggnad med enkla medel : en fallstudie på Hofors mödravårdscentral

Andersson, Niklas January 2016 (has links)
I centrala Hofors ligger vårdcentralen som ingår i Hoforshus ABs byggnadsbestånd, byggnaden i sig är uppdelad i en huvudbyggnad och en mindre del där BVC och mödravårdsverksamheten återfinns. Byggnaderna är sammanbundna med en korridor som huvudsakligen är inglasad. Företaget var intresserat av att kartlägga byggnadens energianvändning eftersom denna föreföll relativt hög, dessutom hade brukarna i byggnaden uttryckt sitt missnöje med inneklimatet under såväl sommar- som vintertid. På grund av den verksamheten i byggnaden var lösningar som inte stör denna av högsta intresse. Studien som genomförts har haft främsta fokus på byggnadens klimatskal och fram för allt på glasgångens inverkan på den övriga byggnaden. Det kan förutsättas att den höga andelen glas i den här delen av byggnaden påverkar dess inneklimat negativt medtanke på de låga U-värdet hos glas och den solvärmelast som detta ger under sommartid då värmetillskottet inte är önskat. En litteraturstudie för att undersöka hur människor upplever inneklimatet samt hur en tillförlitlig simuleringsmodell för en byggnad har genomförts. Studien resulterade i en förståelse för hur inneklimatet upplevs och kvantifieras samt en förståelse för vad som är viktigt vid insamling av data till en simuleringsmodell. Med tanke på hur indata skall hämtas enligt litteraturstudien har så mycket data som möjligt mätts upp via undersökningar och egna observationer, ritningar har undersökts och deras validitet har undersökts genom uppmätning av byggnaden, blower-door har genomförts samt temperatur- och relativånghaltloggning. Momentanvärden. på FTX-systemet för att beräknas dess verkningsgrad. Linjära köldbryggor har undersökts med finitelementmetod i programmet Comsol multiphysics 3,5. För validering av simuleringsmodellen har uppmätta energiförbrukningen använts och jämförts med simuleringens resultat. Simuleringarna är genomförda i BV2. Resultatet av studien visar som tidigare förväntat på glasgångens negativa inverkan på byggnadens inneklimat temperaturen loggades mellan den 12 april och 9 maj 2016 högsta temperaturen var 30°C och lägsta 15°C vilket är en större spridning jämfört med övriga utrymmen där temperaturen loggats. Simuleringarna som genomfördes av glasgången visar att denna förbrukar mellan 5000-5500 kWh med bruksarean 13,5 m2. Slutligen resulterade studien i rekommenderade åtgärder för byggnaden som innefattar tilläggsisolering av vindsbjälklag, utbyte av ett mindre väggparti, sänkning av temperaturen med 1°C samt en del underhållsåtgärder för att förbättra inneklimatet. Åtgärderna antas vara möjliga att genomföra utan att verksamheten störs. Föreslagna åtgärder förefaller också relativt lönsamma enligt pay-off metoden. / In the central parts of Hofors a healthcenter is located which is included in Hoforshus AB's building stock, the building itself is divided into a main building and a smaller one in which the child health center and maternity care is located. The buildings are connected by a corridor substantially glazed. Now they are interested in maping the building's energyusage as this is relatively high, in addition, the users of the building had been dissatisfied with the indoor climate in both summer and winter. Because of the healtcare activities the owners were most interested in finding solutions that would not interfere with it. The study conducted has had a primary focus on the building envelope and above all on the glazed corridor’s impact on the rest of the building. One can assume that the high proportion of glass in this part of the building affects the indoor climate negatively keeping in mind the low U-value of the glass and the solar heat load, this gives during the summer when heat gain is not desired. A literature study to investigate how people perceive the climate as well as how to make a reliable simulation model of a building has been completed. The study resulted in an understanding of how the indoor climate is perceived and quantified, and also in an understanding of what is important in the collection of data for the simulation model. Keeping in mind how data should be collected according to the literature reviwe- have as much data as possible measured through surveys and own observations, blueprints have been studied and their validity has been investigated by measuring the building, blower door has been performed and temperature- and relative humidityloggning. Instantaneous values of the FTX system was made to calculate its efficiency. Linear thermal bridges have been investigated by finite element method in the program COMSOL Multiphysics 3.5. For validation of the simulated model the results of it were compared with the acutal measured energyconsumption of the building. The simulations were performed in BV2. The results of the study show, as expected, the glazed corridor’s negative impact on the building's indoor climate. Temperature was logged between 160412-160509 highest temperature was 30 ° C and minimum 15 ° C, which is more widespread than in other areas where the temperature was logged. The simulations that were performed on the glazed corridor shows that it consumes between 5000-5500 kWh on the area of 13.5 m2. Finally the study resulted in recommendations for the building that includes additional insulation of the attic, replacement of a smaller wall section, lowering the temperature by 1 ° C, as well as some maintenance measures to improve the indoor climate. The measures are believed to be possible to implement without significant interference with the health care acitivities. In addition the proposed measures seem profitable according to the pay of method.
30

Optimal fönsterstorlek för kontors- och behandlingsrum – Länssjukhuset Kalmar / Optimal window size for office- and treatment rooms – County Hospital Kalmar

Nicoară, Alexandru, Carlsén, Arvid January 2019 (has links)
Detta examensarbete beskriver optimeringsprocessen för ett fönster utifrån relevanta parametrar som tillämpas i Miljöbyggnad 3.0 med avseende på energi och inomhusmiljö. Miljöbyggnad 3.0 är ett miljöcertifieringsystem som bygger på Boverkets Byggregler och Arbetsmiljöverkets regler om arbetsmiljö. De parametrar som fönsterstorleken optimerats utifrån är solvärmelasten, värmeeffektbehovet, den specifika energianvändningen, dagsljuset samt det termiska inneklimatet sommar- och vinter. För betyget i Miljöbyggnad 3.0 på dessa parametrar har fönstrets storlek i förhållande till rummets storlek en avgörande betydelse. Objekten för studien bestod av två typrum, ett behandlingsrum och ett kontorsrum, som kommer att ligga i en framtida byggnad vid Kalmars Länssjukhus. Med hjälp av utredningar och jämförelser mellan teoretiska utgångspunkter och praktiska simuleringar på relevanta parametrar som tillämpas i Miljöbyggnad 3.0 har endast två fönstermått valts för att uppnå minst betygen SILVER i Miljöbyggnad 3.0. Påverkan av invändiga solskydd har även studerats i arbetet.

Page generated in 0.068 seconds