• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • Tagged with
  • 73
  • 73
  • 35
  • 35
  • 30
  • 29
  • 23
  • 15
  • 14
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Influência do laser de baixa potência (GaAIAs - λ830nm) na formação óssea em implantes lisos e texturizados: uma análise histomorfométrica

Torres, Marco Antônio Rambo Osório January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:31Z (GMT). No. of bitstreams: 2 000399356-0.pdf: 4105847 bytes, checksum: 0c59a09fa1073f779a885d9635fec74e (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This research in vivo blind-controlled was to investigate post mortem, through the histomorphometrical analysis, the influence of the low power laser in bone formation on machined and roughened titanium dental implants inserted in rabbits tibia-bones. The animals were subjected or not to the GaAlAs irradiation laser device, with a length of wave of 830nm, in a continuous form during 10 seconds, with a power output of 100mW. A total of six white New Zealand rabbits were equally and randomly divided into two groups, irradiated and controlled groups, where four implants were placed in each animal. Two machined were implanted in the right tibia and two roughened in the left tibia. The experimental group received irradiation through the skin in three points around the implants, during 15 days, every 48 hours. The first application was performed in the same day of the surgery, with a total of eight days of irradiation and total dose of 24J/cm2 in each tibia (3 points x 1J x 8 applications = 24J). The control group were submitted to the same routine of the irradiated animals, however with the laser equipment turned off. After 30 days all animals suffered euthanasia, and histological sections were obtained. The sections were then stained with toluidine blue. Each section was reduced to a final thickness of about 10 to 19μm. The bone-to-implant contact measurements in percentage were performed by using two central sections from each sample, blinded form, were photomicrographed on optical microscope connected to an image analyzer digital program. The averages obtained from the two sections of each implant right after the blinding belittled were compared in general form between laser and control groups and among the four sub-groups were performed by using Student’s t-test. There was no statistically significant difference (p> 0,05) in the percentage of bone-to-implant contact between the laser (77,048 % ± 10,173) and control groups (69,516 % ± 19,284) in a general form, not even between the sub-groups roughened with laser (81,530 % ± 10,155), roughened control (72,190 % ± 16,778), machined with laser (72,565 % ± 8,737) and machined control (66,842 % ± 22,791). In the present research, results suggest that the low power laser, with the irradiated protocol, did not significantly contribute for increasing the percentage of bone-to-implant contact. Nevertheless, new formed bone undergone to the with GaAlAs irradiation laser device during the period of osseointegration, it seems to present a bigger vasculature and lamellar organization compared to the control group, suggesting bone maturation improvement. However, further research is necessary to better explain the biological mechanisms of low power laser action on the mediation of necessary process for titanium implants osseintegration as well as dosimetric parameters for getting bone biostimulation. / Este trabalho in vivo controlado e com cegamento avaliou post mortem, através da análise histomorfométrica, a influência do laser de baixa potência na formação óssea em implantes lisos e texturizados inseridos em tíbias de coelhos, submetidos ou não à irradiação com laser de GaAlAs com comprimento de onda de 830nm, de forma contínua por 10 segundos, com potência de 100mW. Para tanto foram utilizados seis coelhos da raça Nova Zelândia, distribuídos igualmente de forma aleatória em grupo irradiado e grupo controle, onde cada coelho recebeu quatro implantes, sendo dois lisos na tíbia direita e dois texturizados na tíbia esquerda. Os animais do grupo experimental receberam irradiação transcutaneamente em três pontos ao redor dos implantes, durante 15 dias a cada 48 horas, sendo a primeira aplicação no dia da cirurgia, com total de oito dias de irradiação e dose total de 24J/cm2 em cada tíbia (3 pontos x 1J x 8 aplicações = 24J).Os animais do grupo controle foram submetidos à mesma rotina dos animais irradiados, porém com equipamento laser desligado. Após 30 dias todos os animais sofreram eutanásia para obtenção de lâminas histológicas coradas com azul de toluidina a partir de cortes das tíbias com os implantes inseridos numa espessura final de 10 a 19μm. Para avaliação do percentual de contato osso-implante os dois cortes mais centrais de cada amostra, de forma cegada, foram fotomicrografados em microscópio óptico e analisados através de um programa digital de processamento de imagens. As médias obtidas a partir dos dois cortes de cada implante, após desfeito o cegamento, foram comparadas de forma geral e dentro dos grupos utilizando-se o teste t-student. Não houve diferença estatisticamente significativa (p>0,05) no percentual de contato osso-implante entre os grupos laser (77,048% ± 10,173) e controle (69,516% ± 19,284) de forma geral, nem entre os subgrupos texturizado com laser (81,530% ± 10,155), texturizado controle (72,190% ± 16,778), liso com laser (72,565% ± 8,737) e liso controle (66,842% ± 22,791).Estes resultados sugerem que o laser de baixa potência, com o protocolo de irradiação utilizado neste modelo animal, não contribuiu significativamente para o aumento do percentual de contato osso-implante. Não obstante, o osso novo formado submetido à irradiação com laser de GaAlAs durante o período de ossoeintegração, parece apresentar uma maior vascularização e organização lamelar que o grupo controle, sugerindo uma maior maturação. Porém, são necessárias novas pesquisas de modo a preencher as lacunas ainda existentes quanto ao entendimento dos mecanismos biológicos da ação do laser de baixa potência na mediação dos processos necessários à osseointegração de implantes de titânio, bem como dos parâmetros dosimétricos para obtenção da bioestimulação óssea.
62

Efeitos locais e sistêmicos da LLLT no reparo ósseo inicial de áreas com parafuso PLLA-PGA : estudo em coelhos

Coelho, Rodrigo Carvalho Pinto January 2012 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2012-05-22T12:09:47Z No. of bitstreams: 1 438469.pdf: 2270698 bytes, checksum: 0a929a3fccfe283897a59206f4e6936d (MD5) / Made available in DSpace on 2012-05-22T12:09:47Z (GMT). No. of bitstreams: 1 438469.pdf: 2270698 bytes, checksum: 0a929a3fccfe283897a59206f4e6936d (MD5) / A presente pesquisa avaliou os efeitos locais e sistêmicos da LLLT no processo inicial de reparo ósseo, após a implantação de um parafuso PLLA-PGA em tíbias de 24 coelhos linhagem Nova Zelândia. A amostra foi dividida aleatoriamente em 2 grupos, experimental e controle. Em cada animal, foi implantado 1 parafuso PLLA-PGA de 5mm de comprimento por 1,5mm de diâmetro em cada tíbia, direita e esquerda. No grupo experimental, os coelhos receberam aplicações de laser infravermelho (830nm; 4J/cm2; 100mW; 40,4 segundos), apenas na pata direita, no pós-operatório imediato e a cada 48 horas, até o máximo de 7 aplicações. O grupo controle não foi irradiado. Ambos foram divididos em 3 subgrupos, de acordo com o tempo de observação de 5, 15 e 30 dias, após o qual os animais foram mortos e submetidos à análise histológica para avaliação do grau de formação óssea perimplantar. Esta foi mensurada pelo número de campos de aumento de 200 vezes, ao microscópio ótico, que apresentavam osso neoformado perimplantar. Foram comparados os resultados entre as patas direita do grupo experimental, esquerda do grupo experimental e ambas as patas do grupo controle, ao longo dos 3 períodos de observação. Os resultados da análise quantitativa demonstraram que houve uma maior formação óssea inicial nas patas direita e esquerda do grupo experimental, quando comparadas às amostras do grupo controle, no período de 5 dias. A análise descritiva mostrou que as trabéculas dos animais irradiados, em 5 dias, apresentavam-se ligeiramente maiores e com maior distribuição. Nos demais intervalos, não houve diferenças estatisticamente significativas. A LLLT, nos padrões utilizados, acelerou a formação óssea precoce no intervalo de 5 dias. / This study evaluated the local and systemic effects of LLLT in the initial process of bone repair after implantation of a PLLA-PGA screw in tibia of 24 New Zealand white rabbits. The sample was randomly divided into two groups, experimental and control. A PLLA-PGA screw was implanted in each tibia. In the experimental group, rabbits received applications of infrared laser (830nm, 4J/cm2, 100mW, 40.4 sec), only in the right tibia, in the immediate postoperative period and every 48 hours up to a maximum of 7 applications. The control group was not irradiated. Both were divided into 3 subgroups according to the observation time of 5, 15 and 30 days, after which the animals were killed. A histological analysis was performed to assess the degree of peri-implant bone formation, using a quantitative parameter and qualitative analysis. We compared the results between the right and the left tibia of the experimental group and both tibias of the control group over the three observation periods. The results of quantitative analysis showed greater initial bone formation in both tibias of the experimental group compared to the control group, in 5 days. The descriptive analysis showed that the newly formed trabeculae of the irradiated bones were slightly larger and thicker, in 5 days. In the other intervals, there were no statistically significant differences. The LLLT accelerated bone formation in 5 days, exerting both local and systemic effects.
63

Análise do efeito sistêmico da LLLT em região perimplantar : estudo em coelhos

Mayer, Luciano January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-04-17T13:33:15Z No. of bitstreams: 1 447176.pdf: 2750615 bytes, checksum: 6db2237c9889f4756aec07a95d930df2 (MD5) / Made available in DSpace on 2013-04-17T13:33:16Z (GMT). No. of bitstreams: 1 447176.pdf: 2750615 bytes, checksum: 6db2237c9889f4756aec07a95d930df2 (MD5) / Este estudo é parte de um projeto que teve por objetivo avaliar o efeito da terapia com laser de baixa intensidade pós-implante dentário osseointegrável no funcionamento da glândula tireoide e, consequentemente, na regulação do cálcio, através da mensuração dos níveis hormonais de Triiodotironina (T3), Tiroxina (T4) e dos níveis de Cálcio e Albumina no soro sanguíneo de coelhos. Foi avaliado o efeito de 3 doses terapêuticas distintas de LLLT utilizadas para aceleração do processo de osseointegração de implantes dentários. Para tanto, foram utilizados 40 coelhos da ordem Lagomorpha, raça Nova Zelândia, machos, pesando entre 3 e 4 kg, clinicamente sadios, distribuídos aleatoriamente em cinco grupos, com oito animais cada, sendo dois grupos designados como controle: o grupo controle CI (animais não irradiados e não operados) e o grupo controle CII (animais não irradiados); e três grupos designados como experimentais: EI, EII e EIII – animais irradiados com três doses distintas de laser – grupo experimental EI (dose total - 70J/cm²), grupo experimental EII (dose total - 35J/cm²) e grupo experimental EIII (dose total - 140J/cm²). Para padronizar os experimentos, todos os animais dos grupos CII, EI, EII e EIII foram submetidos ao procedimento cirúrgico de exodontia do incisivo inferior esquerdo e colocação imediata de um implante osseointegrável com superfície nanotexturizada (Nanotite® - Biomet 3iTM) no respectivo alvéolo, criando uma condição clínica inicial de igualdade entre os quatro grupos operados. Os animais do grupo controle CI participaram da mesma rotina dos demais; no entanto, não foram submetidos a nenhum dos procedimentos clínicos/cirúrgicos, servindo como controle absoluto nos testes imunológicos para contagem de T3, T4, Cálcio e Albumina. Os animais dos grupos experimentais foram irradiados com o laser de diodo infravermelho com meio ativo GaAlAs (Arseneto de Gálio e Alumínio), com comprimento de onda de 830nm, de forma pontual, com potência de 50mW, no modo de emissão contínua, a cada 48 horas, num total de sete sessões de aplicação, durante o período de 13 dias. O protocolo de irradiação foi iniciado imediatamente após o procedimento cirúrgico. As coletas de sangue para dosagens laboratoriais de T3, T4, Cálcio e Albumina foram realizadas por meio de punção venosa da veia jugular nos cinco grupos em quatro momentos distintos: 72 horas antes do procedimento cirúrgico, imediatamente após a primeira aplicação de laser, 72 horas após a primeira aplicação de laser e 72 horas após a última aplicação de laser. Os resultados obtidos demonstraram diferenças estatisticamente significativas para os valores de T3 e Cálcio entre os grupos estudados e para os valores de T3, T4, Cálcio e Albumina nos diferentes tempos de coleta ao longo do experimento. Conclui-se que a LLLT, no protocolo de irradiação utilizado neste estudo, apesar de ter alterado significativamente os níveis hormonais de T3 e T4 e os níveis de Cálcio e Albumina circulantes no soro de coelhos, não comprometeu definitivamente o funcionamento da glândula tireoide dos mesmos, pois na etapa final do controle hormonal percebe-se o restabelecimento da função glandular. / This study is part of a larger project that sought to assess the effect of lowlevel laser therapy (LLLT) after placement of an osseointegrated dental implant on thyroid gland function – and, consequently, calcium regulation – and its potential interference with the osseointegration process. Toward this end, circulating serum levels of triiodothyronine (T3), thyroxine (T4), calcium, and albumin were measured in rabbits. The effects of three therapeutic doses of LLLT, used to accelerate the dental implant osseointegration process, were assessed. Forty healthy male New Zealand rabbits (order Lagomorpha), weight 3–4 kg, were allocated randomly across five groups of eight each: two control groups, CI (no LLLT, no surgery) and CII (no LLLT), and three experimental groups, EI, EII, EIII, exposed to three different doses of laser radiation (EI, total dose 70 J/cm²; EII, total dose 35 J/cm²; and EIII, total dose 140 J/cm²). For standardization purposes, all animals in groups CII, EI, EII, and EIII underwent surgical extraction of the mandibular left incisor and immediate placement of a nanoparticle-coated osseointegrated implant (NanoTite® – Biomet 3iTM) into the prepared socket, creating a condition of equality between groups at baseline. Animals in group CI were exposed to the same handling conditions, but did not undergo any clinical or surgical procedures, thus serving as an absolute control for T3, T4, calcium, and albumin measurements. Animals in the experimental groups received spot irradiation with a GaAlAs (gallium aluminium arsenide) infrared diode laser, wavelength 830 nm, power 50 mW, in continuous emission mode, over two points, every 48 hours over 13 days, for a total of seven sessions; the irradiation protocol was started immediately after the surgical procedure. Blood was collected for measurement of T3, T4, calcium, and albumin levels, by puncture of the external jugular vein, at four points in time: 72 hours before surgery, immediately after the first LLLT session, 72 hours after the first LLLT session and 72 hours after the last LLLT session. The results showed significant differences in T3 and calcium levels between study groups, as well as significant within-group differences in T3, T4, calcium, and albumin levels over time. We conclude that, despite a significant effect on circulating serum levels of T3, T4, calcium and albumin, the LLLT protocol used in this study did not lead to impairment of thyroid function in a rabbit model, because in the final stage of the hormonal control it is noticed the reestablishment of glandular function.
64

An?lise da densidade ?ssea e da atenua??o do feixe de raios X nos tecidos moles, em mand?bula de coelhos submetidos ? lasertarapia, durante a distra??o osteog?nica

Cenci, Rodrigo Alberto 08 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:09Z (GMT). No. of bitstreams: 1 438173.pdf: 1856345 bytes, checksum: 88a20c5de7a402c873dcfd4ecbe6460d (MD5) Previous issue date: 2012-03-08 / INTRODUCTION: Cone-beam computed tomography (CBTC) provides detailed information about the amount and quality of new bone formed during distraction osteogenesis (DO). The density of the lengthened bone is measured based on different levels of gray found in the images. The use of CBTC therefore allows to perform a quantitative analysis of bone density and, thus, to measure the level of X-ray attenuation by soft tissues. OBJECTIVES: To assess, via CBTC, newly formed bone in mandibles of rabbits treated with DO under the biomodulating effects of AsGaAl infrared laser radiation (λ=830 nm, 40 mW), applied during the activation phase. The distracted area was assessed based on the gray levels shown on images and observing the influence of soft tissues on X-ray attenuation. MATERIALS AND METHODS: Ten rabbits were used (two experimental groups and one control group). The two experimental groups were treated with DO and low-level laser therapy. Rabbits in experimental group A were killed 11 days after the beginning of DO, and those in experimental group B, after 21 days of DO. CBTC images were obtained from the mandibles of the ten rabbits with soft tissues and subsequently (after dissection) without soft tissues. This comparison allowed to analyze the influence of soft tissues on X-ray attenuation, and consequently on the decrease in gray levels observed in the tomographs of rabbits treated with DO. RESULTS: The presence of soft tissues increased X-ray attenuation, resulting in a decrease in the levels of gray observed in three-dimensional CBCT images of mandibular bone tissue of the rabbits before and after soft tissue removal. The area of the mandibles treated with DO presented higher levels of gray in rabbits killed at 21 days. CONCLUSIONS: CBCT allowed to assess bone density variation in areas treated with DO. The presence of soft tissues contributes to decrease the levels of gray in three-dimensional CBCT bone tissue images of the ten rabbits assessed. This occurs due to the absorption of X-rays by soft tissues studied by tomography. We found that bone density in the area treated with DO, as observed on tomography, increased in direct proportion to the bone maturation period after the activation phase in DO, based on the gray levels observed. / INTRODU??O: A tomografia computadorizada do tipo Cone-beam (TCCB) fornece informa??es detalhadas sobre a qualidade e a quantidade de osso neoformado pela distra??o osteog?nica (DO). Permite mensurar a densidade do osso alongado, por meio da avalia??o dos tons de cinza. Desta forma, pode-se realizar uma an?lise quantitativa da densidade ?ssea, dimensionando a atenua??o dos feixes de raios X pelos tecidos moles nas imagens. OBJETIVOS: Avaliar, por interm?dio da TCCB, o osso mandibular neoformado em mand?bulas de coelhos submetidos ? DO, sob efeito biomodulat?rio da irradia??o por laser infravermelho AsGaAl (λ=830 nm, 40 mW), aplicado durante a fase de ativa??o do aparelho distrator. A ?rea da distra??o ? avaliada pelos n?veis de cinza das imagens, observando tamb?m a influ?ncia dos tecidos moles na atenua??o dos feixes de raios X. MATERIAIS E M?TODOS: Dez coelhos foram utilizados (dois grupos experimentais e um grupo controle). Os grupos experimentais foram submetidos ? DO e ? terapia a laser de baixa potencia (LLLT). Os coelhos do grupo experimental A foram mortos ap?s 11 dias do in?cio da DO e os coelhos do grupo experimental B, mortos ap?s 21 dias do in?cio da DO. Os 10 coelhos foram submetidos a tomografia com tecidos moles e posteriormente dissecados e submetidos a tomografia sem tecidos moles. Assim, foi poss?vel analisar a influ?ncia dos tecidos moles em coelhos submetidos ? DO na atenua??o dos feixes de raios X e, consequentemente, na diminui??o dos valores de n?veis de cinza observados na imagem tomogr?fica. RESULTADOS: A presen?a dos tecidos moles aumenta a atenua??o dos feixes de raios X contribuindo na diminui??o dos valores de n?veis de cinza, observados na imagem do tecido ?sseo em 3D, na mand?bula dos 10 coelhos submetidos a tomografia, antes e ap?s a remo??o dos tecidos moles. A ?rea das mand?bulas submetidas ? distra??o apresentaram valores superiores de cinza, nos coelhos mortos ap?s 21 dias do in?cio da DO. CONCLUS?ES: Com tom?grafos do tipo Cone-beam, foi poss?vel avaliar a varia??o da densidade ?ssea em ?reas submetidas ? DO. A presen?a dos tecidos moles contribui na diminui??o dos valores de n?veis de cinza observados nas imagens do tecido ?sseo dos 10 coelhos em 3D. Isto ocorre devido ? absor??o do feixe de raios X pelos tecidos moles submetidos a tomografia. Tamb?m observou-se que a densidade ?ssea na ?rea da distra??o, visualizada na tomografia, aumenta proporcionalmente ao per?odo de matura??o ?ssea ocorrido ap?s a fase de ativa??o da DO, conforme observa??o dos valores de cinza obtidos.
65

Efeitos locais e sist?micos da LLLT no reparo ?sseo inicial de ?reas com parafuso PLLA-PGA : estudo em coelhos

Coelho, Rodrigo Carvalho Pinto 22 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:11Z (GMT). No. of bitstreams: 1 438469.pdf: 2270698 bytes, checksum: 0a929a3fccfe283897a59206f4e6936d (MD5) Previous issue date: 2012-03-22 / This study evaluated the local and systemic effects of LLLT in the initial process of bone repair after implantation of a PLLA-PGA screw in tibia of 24 New Zealand white rabbits. The sample was randomly divided into two groups, experimental and control. A PLLA-PGA screw was implanted in each tibia. In the experimental group, rabbits received applications of infrared laser (830nm, 4J/cm2, 100mW, 40.4 sec), only in the right tibia, in the immediate postoperative period and every 48 hours up to a maximum of 7 applications. The control group was not irradiated. Both were divided into 3 subgroups according to the observation time of 5, 15 and 30 days, after which the animals were killed. A histological analysis was performed to assess the degree of peri-implant bone formation, using a quantitative parameter and qualitative analysis. We compared the results between the right and the left tibia of the experimental group and both tibias of the control group over the three observation periods.The results of quantitative analysis showed greater initial bone formation in both tibias of the experimental group compared to the control group, in 5 days. The descriptive analysis showed that the newly formed trabeculae of the irradiated bones were slightly larger and thicker, in 5 days. In the other intervals, there were no statistically significant differences. The LLLT accelerated bone formation in 5 days, exerting both local and systemic effects. / A presente pesquisa avaliou os efeitos locais e sist?micos da LLLT no processo inicial de reparo ?sseo, ap?s a implanta??o de um parafuso PLLA-PGA em t?bias de 24 coelhos linhagem Nova Zel?ndia. A amostra foi dividida aleatoriamente em 2 grupos, experimental e controle. Em cada animal, foi implantado 1 parafuso PLLA-PGA de 5mm de comprimento por 1,5mm de di?metro em cada t?bia, direita e esquerda. No grupo experimental, os coelhos receberam aplica??es de laser infravermelho (830nm; 4J/cm2; 100mW; 40,4 segundos), apenas na pata direita, no p?s-operat?rio imediato e a cada 48 horas, at? o m?ximo de 7 aplica??es. O grupo controle n?o foi irradiado. Ambos foram divididos em 3 subgrupos, de acordo com o tempo de observa??o de 5, 15 e 30 dias, ap?s o qual os animais foram mortos e submetidos ? an?lise histol?gica para avalia??o do grau de forma??o ?ssea perimplantar. Esta foi mensurada pelo n?mero de campos de aumento de 200 vezes, ao microsc?pio ?tico, que apresentavam osso neoformado perimplantar. Foram comparados os resultados entre as patas direita do grupo experimental, esquerda do grupo experimental e ambas as patas do grupo controle, ao longo dos 3 per?odos de observa??o.Os resultados da an?lise quantitativa demonstraram que houve uma maior forma??o ?ssea inicial nas patas direita e esquerda do grupo experimental, quando comparadas ?s amostras do grupo controle, no per?odo de 5 dias. A an?lise descritiva mostrou que as trab?culas dos animais irradiados, em 5 dias, apresentavam-se ligeiramente maiores e com maior distribui??o. Nos demais intervalos, n?o houve diferen?as estatisticamente significativas. A LLLT, nos padr?es utilizados, acelerou a forma??o ?ssea precoce no intervalo de 5 dias.
66

An?lise do efeito sist?mico da LLLT em regi?o perimplantar : estudo em coelhos

Mayer, Luciano 12 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:20Z (GMT). No. of bitstreams: 1 447176.pdf: 2750615 bytes, checksum: 6db2237c9889f4756aec07a95d930df2 (MD5) Previous issue date: 2013-03-12 / This study is part of a larger project that sought to assess the effect of lowlevel laser therapy (LLLT) after placement of an osseointegrated dental implant on thyroid gland function and, consequently, calcium regulation and its potential interference with the osseointegration process. Toward this end, circulating serum levels of triiodothyronine (T3), thyroxine (T4), calcium, and albumin were measured in rabbits. The effects of three therapeutic doses of LLLT, used to accelerate the dental implant osseointegration process, were assessed. Forty healthy male New Zealand rabbits (order Lagomorpha), weight 3 4 kg, were allocated randomly across five groups of eight each: two control groups, CI (no LLLT, no surgery) and CII (no LLLT), and three experimental groups, EI, EII, EIII, exposed to three different doses of laser radiation (EI, total dose 70 J/cm?; EII, total dose 35 J/cm?; and EIII, total dose 140 J/cm?). For standardization purposes, all animals in groups CII, EI, EII, and EIII underwent surgical extraction of the mandibular left incisor and immediate placement of a nanoparticle-coated osseointegrated implant (NanoTite? Biomet 3iTM) into the prepared socket, creating a condition of equality between groups at baseline. Animals in group CI were exposed to the same handling conditions, but did not undergo any clinical or surgical procedures, thus serving as an absolute control for T3, T4, calcium, and albumin measurements. Animals in the experimental groups received spot irradiation with a GaAlAs (gallium aluminium arsenide) infrared diode laser, wavelength 830 nm, power 50 mW, in continuous emission mode, over two points, every 48 hours over 13 days, for a total of seven sessions; the irradiation protocol was started immediately after the surgical procedure. Blood was collected for measurement of T3, T4, calcium, and albumin levels, by puncture of the external jugular vein, at four points in time: 72 hours before surgery, immediately after the first LLLT session, 72 hours after the first LLLT session and 72 hours after the last LLLT session. The results showed significant differences in T3 and calcium levels between study groups, as well as significant within-group differences in T3, T4, calcium, and albumin levels over time. We conclude that, despite a significant effect on circulating serum levels of T3, T4, calcium and albumin, the LLLT protocol used in this study did not lead to impairment of thyroid function in a rabbit model, because in the final stage of the hormonal control it is noticed the reestablishment of glandular function. / Este estudo ? parte de um projeto que teve por objetivo avaliar o efeito da terapia com laser de baixa intensidade p?s-implante dent?rio osseointegr?vel no funcionamento da gl?ndula tireoide e, consequentemente, na regula??o do c?lcio, atrav?s da mensura??o dos n?veis hormonais de Triiodotironina (T3), Tiroxina (T4) e dos n?veis de C?lcio e Albumina no soro sangu?neo de coelhos. Foi avaliado o efeito de 3 doses terap?uticas distintas de LLLT utilizadas para acelera??o do processo de osseointegra??o de implantes dent?rios. Para tanto, foram utilizados 40 coelhos da ordem Lagomorpha, ra?a Nova Zel?ndia, machos, pesando entre 3 e 4 kg, clinicamente sadios, distribu?dos aleatoriamente em cinco grupos, com oito animais cada, sendo dois grupos designados como controle: o grupo controle CI (animais n?o irradiados e n?o operados) e o grupo controle CII (animais n?o irradiados); e tr?s grupos designados como experimentais: EI, EII e EIII animais irradiados com tr?s doses distintas de laser grupo experimental EI (dose total - 70J/cm?), grupo experimental EII (dose total - 35J/cm?) e grupo experimental EIII (dose total - 140J/cm?). Para padronizar os experimentos, todos os animais dos grupos CII, EI, EII e EIII foram submetidos ao procedimento cir?rgico de exodontia do incisivo inferior esquerdo e coloca??o imediata de um implante osseointegr?vel com superf?cie nanotexturizada (Nanotite? - Biomet 3iTM) no respectivo alv?olo, criando uma condi??o cl?nica inicial de igualdade entre os quatro grupos operados. Os animais do grupo controle CI participaram da mesma rotina dos demais; no entanto, n?o foram submetidos a nenhum dos procedimentos cl?nicos/cir?rgicos, servindo como controle absoluto nos testes imunol?gicos para contagem de T3, T4, C?lcio e Albumina. Os animais dos grupos experimentais foram irradiados com o laser de diodo infravermelho com meio ativo GaAlAs (Arseneto de G?lio e Alum?nio), com comprimento de onda de 830nm, de forma pontual, com pot?ncia de 50mW, no modo de emiss?o cont?nua, a cada 48 horas, num total de sete sess?es de aplica??o, durante o per?odo de 13 dias. O protocolo de irradia??o foi iniciado imediatamente ap?s o procedimento cir?rgico. As coletas de sangue para dosagens laboratoriais de T3, T4, C?lcio e Albumina foram realizadas por meio de pun??o venosa da veia jugular nos cinco grupos em quatro momentos distintos: 72 horas antes do procedimento cir?rgico, imediatamente ap?s a primeira aplica??o de laser, 72 horas ap?s a primeira aplica??o de laser e 72 horas ap?s a ?ltima aplica??o de laser. Os resultados obtidos demonstraram diferen?as estatisticamente significativas para os valores de T3 e C?lcio entre os grupos estudados e para os valores de T3, T4, C?lcio e Albumina nos diferentes tempos de coleta ao longo do experimento. Conclui-se que a LLLT, no protocolo de irradia??o utilizado neste estudo, apesar de ter alterado significativamente os n?veis hormonais de T3 e T4 e os n?veis de C?lcio e Albumina circulantes no soro de coelhos, n?o comprometeu definitivamente o funcionamento da gl?ndula tireoide dos mesmos, pois na etapa final do controle hormonal percebe-se o restabelecimento da fun??o glandular.
67

Avalia??o da a??o do laser (AsGaAl) no torque de remo??o de implantes lisos e texturizados

Meyer, Kleber Ricardo Monteiro 14 October 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:20Z (GMT). No. of bitstreams: 1 408029.pdf: 5297005 bytes, checksum: b759a1194fe1debd841abcedaff116d7 (MD5) Previous issue date: 2008-10-14 / Este trabalho avaliou o efeito do laser (AsGaAl) atrav?s de torque de remo??o, em diferentes per?odos de cicatriza??o, de implantes modelo standard lisos e texturizados, colocados em t?bias de coelhos machos da ra?a Nova Zel?ndia, submetidos ou n?o ? irradia??o com laser de baixa intensidade. Para o estudo foram utilizados 16 animais, pesando entre 3,5 a 4,0 quilos, sendo inseridos dois implantes em cada t?bia, divididos em quatro grupos (controle e laser para 16 e 30 dias de cicatriza??o). O laser (AsGaAl) foi aplicado com comprimento de onda de 830nm, modo cont?nuo e pot?ncia de 100mW, sendo a aplica??o pontual de 1J/cm? em tr?s pontos e oito aplica??es, com intervalo de 48 horas, iniciada imediatamente ap?s a cirurgia de coloca??o dos implantes, perfazendo um total de 24J/cm?. Ap?s o per?odo de cicatriza??o, os animais foram mortos, ent?o, realizada a remo??o das t?bias e, em seguida, a medi??o dos torques para remo??o dos implantes com torqu?metro el?trico digital de empunhadura manual. Os resultados de torque de remo??o obtidos para os grupos controle: Implantes lisos com 16 dias (20,42?3,06Ncm) e 30 dias (27,42?19,65Ncm); implantes texturizados com 16 dias (22,67?11,07Ncm) e 30 dias (30,46?16,06Ncm). Para os grupos laser: Implantes lisos com 16 dias (19,15?4,65Ncm) e 30 dias (30,08?4,14Ncm); implantes texturizados com 16 dias (20,48?6,72Ncm) e 30 dias (23,45?10,40Ncm). A partir dos resultados da An?lise de Vari?ncia Fatorial, verificou-se que existe diferen?a significativa para os resultados desta pesquisa sob analise do fator isolado tempo, onde observou-se que, no per?odo de 30 dias, os valores do torque de remo??o s?o superiores ao periodo de 16 dias.
68

Efetividade da fluorescência a laser no diagnóstico de lesões de cárie. Estudos in vitro e in vivo

Diniz, Michele Baffi [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T18:31:58Z : No. of bitstreams: 1 diniz_mb_me_arafo.pdf: 3188878 bytes, checksum: afb48495eaac71c8663023ac0c8eba58 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente estudo foi avaliar a efetividade da fluorescência a laser (KaVo DIAGNOdent) para a determinação da severidade de lesões de cárie oclusal em dentes permanentes in vivo e para determinação da remineralização in vitro de lesões de cárie induzidas artificialmente em esmalte de dentes bovinos. No estudo in vitro, 78 blocos de esmalte com lesões de cárie artificial (mancha branca) com valores de dureza Vickers de 38,48 l 0,85 foram submetidos ao tratamento com dentifrício fluoretado durante a ciclagem de pH, para promover a remineralização. Antes do início do experimento, após a desmineralização e após a remineralização foram realizadas análises com a fluorescência a laser e análises de microdureza superficial do esmalte. Foram encontradas diferenças significantes nas medidas de microdureza superficial (p < 0,0001) nas 3 etapas. Os valores encontrados nas leituras com a fluorescência a laser foram extremamente baixos (entre 0-5), apresentando diferença estaticamente significante somente após a remineralização. No estudo in vivo, foram selecionados 130 sítios de primeiros molares permanentes hígidos ou com presença de lesões de cárie incipientes na superfície oclusal, em crianças com idade entre 7 a 12 anos. Após profilaxia, foi realizada a inspeção visual pelo Examinador A e 23 o exame com o DIAGNOdent pelo Examinador B. Apenas os sítios com sinais sugerindo lesão de cárie foram abertos com equipamentos que permitiram preparos conservadores e a extensão da lesão (padrão-ouro) foi determinada pelo Examinador C. De acordo com os pontos de corte propostos pela KaVo (1999) e com os novos pontos de corte estabelecidos pela curva ROC, observamos uma diferença na especificidade, 0,31 e 0,85 respectivamente, considerando todas as lesões como cariadas, e um equilíbrio entre sensibilidade.... / The purpose of this study was to evaluate the effectiveness of laser fluorescence device (DIAGNOdent) in detecting in vivo depth of occlusal caries lesions in permanent teeth and detecting in vitro remineralization of artificial caries lesions in enamel bovine teeth. On in vitro study, 78 enamel blocks with artificial caries lesions (white spot lesions) with Vickers microhardness number of 38.48 l 0.85 were submitted to dentifrice treatment during the pH-cycling, to promote remineralization. At baseline, after demineralization and after remineralization analyses were carried through with laser fluorescence device and enamel superficial microhardness analyses. Significant differences in superficial microhardness measures were found in the 3 stages (p < 0.0001). Values found in laser fluorescence readings were extremely low (between 0-5), presenting difference statistically significant only after remineralization. On in vivo study, one hundred and third sites from occlusal surfaces of sound or carious first permanent molars were selected in children, aged between 7 and 12 years. After professional cleaning, visual inspection was performed by Examiner A and laser fluorescence (DIAGNOdent) assessment by Examiner B. Only the sites presenting signals suggesting caries lesions were opened that resulted from minimal intervention and the 26 lesion extension (gold-standard) was determined by Examiner C. In accordance with cut-off points proposed by KaVo (1999) and with the new cut-off points established by ROC curves, we observe a difference in specificity, 0.31 and 0.85 respectively, considering all lesions as caries, and a balance between sensitivity (0.70) and specificity (0.87) for the new cut-off points considering dentine lesions only. Accuracy for visual inspection was ...(Complete abstract, click electronic address below).
69

Investigação da quebra de pigmentos por luz

Esteban Florez, Fernando Luis [UNESP] 16 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-16Bitstream added on 2014-06-13T20:31:07Z : No. of bitstreams: 1 estebanflorez_fl_me_arafo.pdf: 4818126 bytes, checksum: 136867861dfe8fc2d361248949270525 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O clareamento dental é uma técnica que surgiu no inicio do século XIX. Desde então, e em função dos resultados obtidos ao longo do tempo, esta foi sendo alterada de maneira a reduzir os riscos do procedimento e ao mesmo tempo melhorar o resultado estético obtido. Com o aparecimento das fontes de luz para uso odontológico, novas e interessantes possibilidades surgiram e permitiram a utilização de métodos de aceleração que respeitem a fisiologia pulpar, que diminuam o tempo de exposição do paciente aos agentes peróxidos e promovam ainda a obtenção de bons resultados estéticos. Nos dias de hoje, pode-se observar na literatura importantes questionamentos acerca da contribuição efetiva da luz visível no processo e, os efeitos dos agentes peróxidos nas estruturas cristalinas dos dentes, materiais restauradores em geral e tecidos moles. Estas preocupações foram o cerne da motivação para a realização desta pesquisa, sendo assim, este trabalho vem propor uma série de metodologias inovadoras que avaliem através de tecnologias modernas os mecanismos básicos de interação da luz visível com o peróxido de hidrogênio e com os pigmentos orgânicos. Os experimentos aqui demonstrados abordam os fatores críticos relacionados com a eficiência do processo em diferentes substratos por meio de análise de transmitância, de fluorescência e imagens digitais. Com estes estudos pretendemos responder de maneira objetiva algumas das questões que foram observadas serem de fundamental importância no esclarecimento da real eficiência e eficácia da luz no clareamento dental. / The dental bleaching is a technique that appeared in the beginning of the XIX century. Since then, and in function of the obtained results a long the time, this has been altered in way to reduce the procedure risks and at the same time improve the aesthetic results. With the rise of light sources to be used in dentistry, new and exciting possibilities appeared and allowed the use of catalytic methods that respect the pulpal physiology, which diminishes the exposure time of the patients to the bleaching agents and provides good aesthetic results. In nowadays, it is possible to observe in the literature important questionings over the real contribution of light in the process and, the effects of the peroxide over the crystalline structure of the teeth, restorative materials and soft tissues. These concerning were the major motivation to the realization of this research, in this way, this work proposes a new series of methods that asses by the use of new technologies the basic mechanisms of visible light interaction with the hydrogen peroxide and with the organic pigments. The experiments here demonstrated study the critical factors related with the process efficiency in different substrates by digital images, transmittance and fluorescence. With these studies we pretend to respond in objective way some questions that were observed to be of fundamental importance in the understanding of the light efficiency and efficacy to the dental bleaching.
70

An?lise histol?gica comparativa do reparo ?sseo em osteotomias realizadas por laser de Er:Yag e broca cir?rgica, submetidas ? laserterapia de baixa pot?ncia

Mello, Elaine Duarte Artuso de 05 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:34Z (GMT). No. of bitstreams: 1 385861.pdf: 5094792 bytes, checksum: 3cedf4dd5ca7d55153e9cf47b02bda6a (MD5) Previous issue date: 2006-12-05 / O prop?sito deste estudo foi comparar o processo de reparo ?sseo ap?s osteotomias realizadas em t?bias de ratos por laser de Er:YAG (comprimento de onda de 2,94 &#956;m) e broca cir?rgica em baixa rota??o, sob irriga??o, submetidas ? terapia de laser de baixa pot?ncia (LLLT), com laser de diodo (InGaAlP e GaAIAs), nos comprimentos de onda de 695 nm e 830 nm. Foram utilizados 54 ratos Wistar adultos. Os animais foram divididos em seis grupos: Grupo 1, osteotomia com laser Er:YAG; Grupo 2, osteotomia com laser Er:YAG e LLLT de 685 nm; Grupo 3, osteotomia com laser Er:YAG e LLLT de 830 nm; Grupo 4, osteotomia com broca em baixa rota??o; Grupo 5, osteotomia com broca em baixa rota??o e LLLT de 685 nm; Grupo 6, osteotomia com broca em baixa rota??o e LLLT de 830 nm. O laser de Er:YAG foi utilizado no modo super-pulsado (Q-switch), sem contato, 10 Hz, 500 mJ. Tr?s animais de cada grupo foram mortos aos 7, 14 e 21 dias da cirurgia. Os esp?cimes obtidos foram corados em HE e analisados sob microscopia ?ptica. Aos 7 e 14 dias da cirurgia, os grupos do laser de Er:YAG apresentaram a melhor condi??o de reparo tecidual, comparativamente aos grupos que realizaram osteotomias com broca cir?rgica. O laser de Er:YAG promoveu com sucesso a abla??o do tecido ?sseo, todavia, causou dano t?rmico ?s margens das osteotomias. O laser de Er:YAG promoveu uma fina faixa de tecido alterada, composta por um tecido enegrecido, compat?vel com tecido carbonizado, pr?ximo ? cortical ?ssea. Pr?ximo ? camada carbonizada, foi observado um outro tecido de aspecto amorfo com estruturas indefinidas, produzido por modifica??o tecidual. A m?dia da espessura da camada alterada de tecido foi de 25 &#956;m (?8,7). Os grupos preparados com broca n?o apresentaram qualquer tipo de tecido alterado nas margens de suas osteotomias. Aos 21 dias do p?s-operat?rio, as caracter?sticas histol?gicas foram semelhantes nos seis grupos avaliados, apesar dos tecidos alterados (carbonizado e amorfo) ainda serem vistos nas margens das osteotomias realizadas pelo laser de Er:YAG. A LLLT no comprimento de onda de 685 nm promoveu um reparo ?sseo de padr?o mais organizado e adiantado comparativamente aos grupos que utilizaram a laserterapia de baixa pot?ncia no comprimento de onda de 830 nm.

Page generated in 0.0305 seconds