• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 41
  • 36
  • 19
  • 5
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 179
  • 85
  • 70
  • 60
  • 48
  • 47
  • 29
  • 23
  • 20
  • 18
  • 18
  • 18
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Étude et développement de la spectroscopie d'émission optique sur plasma induit par laser pour la réalisation d'analyses de terrain : application à l'analyse en ligne de métaux dans les liquides

Diaz Rosado, José Carlos 07 March 2013 (has links) (PDF)
La contamination par métaux des eaux est un enjeu de santé publique important. Des contrôles et traitements de plus en plus drastiques sont ainsi effectués sur les eux destinés à la consommation humaine. Il est indispensable, pour cela, de posséder des outils analytiques fiables et sensibles, adaptés aux réglementations existantes et suffisamment souples d'utilisation. La technique de " Laser Induced Breakdown Spectroscopy " (LIBS), ayant fait ses preuves pour l'analyse des solides, y compris dans les explorations exo-terrestres, présente des avantages très intéressants pour les liquides dont, par exemple, sont caractère multi-élémentaire et la possibilité des mesures in-situ de la contamination des eaux par métaux.Un première volet d'étude de ce travail de thèse à permis d'étudier les potentialités de la spectroscopie sur plasma induit par laser (LIBS) pour l'analyse des métaux dissous ou en suspensions dans les eaux. Etude qu'a permis de constater un effet important lié à la taille des particules lors de l'analyse de suspensions. Un deuxième volet consisté à regarder les effets de matrice organique représentée par un acide humique et ceux des minéraux naturels représentés par la bentonite et des particules d'alumine. Effets matrice qu'ont étais corriges par une normalisation par étalon interne.
142

Μέθοδος ταχέως προσδιορισμού κύριων συστατικών μεταλλουργικών σκωρίων (FeO, CaO, MgO, SiO2)

Παλάγκας, Χρήστος 14 January 2009 (has links)
Ο βασικός στόχος της συγκεκριμένης διατριβής ήταν να εξεταστεί η δυνατότητα της τεχνικής LIBS όσον σφορά την ταχεία ποιοτική και ποσοτική ανάλυση της μεταλλουργικής σκωρίας (σε στερεή και υγρή μορφή) σε εργαστηριακή και βιομηχανική κλίμακα. Η τεχνική εφαρμόστηκε αρχικά σε καθαρά μέταλλα και έπειτα σε πρότυπα δείγματα τα οποία περιείχαν τα αντίστοιχα στοιχεία σε μήτρα CaO. Μελετήθηκαν τα χαρακτηριστικά του πλάσματος που παράγεται από παλμούς διάρκειας των τάξεων nsec και psec. Η θερμοκρασία πλάσματος και η ηλεκτρονική πυκνότητα μειώνονται παρόμοια ενώ υπολογίστηκαν ελαφρώς υψηλότερες τιμές στην περίπτωση του ns λέιζερ. Οι καμπύλες βαθμονόμησης έδειξαν πως η ευαισθησία της μεθόδου παραμένει σχεδόν η ίδια ανεξαρτήτως της διάρκειας παλμού. Τα όρια ανίχνευσης κυμάνθηκαν στην τάξη μερικών μερών του εκατομμυρίου (ppm). Στη συνέχεια μελετήθηκαν οι δυνατότητες της τεχνικής για on-line ανάλυση της σκωρίας. Ο δυνατότητες της τεχνικής εξαρτώνται κυρίως από τον λόγο (κρατήρας λέιζερ, ΚΛ)/(μέγεθος σχηματιζόμενης φάσης, ΜΣΦ), οι επιφανειακές ανωμαλίες στην στερεοποιημένη σκωρία καθώς και από την κατανομή του κάθε στοιχείου στην μήτρα. Διαπιστώθηκε πως ο βαθμός ανομοιογένειας της σκωρίας δεν επιδρά σημαντικά στην ακρίβεια της μεθόδου όταν ο λόγος ΚΛ/ΜΣΦ είναι μεγάλος. Σημαντική παράμετρος αποτελεί το γεγονός εάν τα στοιχεία βρίσκονται κατανεμημένα στην μήτρα της σκωρίας ή σε κάποια κρυσταλλική φάση. Η επίδραση των επιφανειακών ανωμαλιών στην ακρίβεια της μεθόδου μειώθηκε με την θραύση και πελλετοποίηση της σκωρίας αλλά, κυρίως για τα στοιχεία τα οποία βρίσκονται κατανεμημένα στην μήτρα της σκωρίας, προτείνεται η αποφυγή της πελλετοποίησης για ανάλυση με χρήση της μεθόδου LIBS. Η ακρίβεια της τεχνικής εξαρτάται σε μεγάλο βαθμό από τα πρότυπα δείγματα που θα χρησιμοποιηθούν για την κατασκευή των καμπύλων βαθμονόμησης. Οι καμπύλες βαθμονόμησης της υγρής σκωρίας εμφάνισαν ικανοποιητική γραμμική εξάρτηση μεταξύ της έντασης των γραμμών εκπομπής των στοιχείων με τις αντίστοιχες συγκεντρώσεις ενώ παρατηρήθηκε μικρή αύξηση όσον αφορά τις τιμές των εντάσεων της υγρής σκωρίας σε σχέση με αυτές της στερεάς σκωρίας κάτω από τις ίδιες πειραματικές συνθήκες. Επίσης παρατηρήθηκε μεγαλύτερη διαπλάτυνση στις γραμμές κάποιων στοιχείων στην υγρή σκωρία. Για συγκεντρώσεις >4-5% παρατηρήθηκε επίσης αύξηση στην κλίση των καμπύλων για την περίπτωση της υγρής σκωρίας. Τέλος, κάθε στοιχείο συμπεριφέρεται διαφορετικά σε σχέση με τα υπόλοιπα, από δείγμα σε δείγμα αλλά και από φάση σε φάση. / To investigate the ability of LIBS technique considering the rapid qualitative and quantitative analysis of metallurgic slag was the main objective of the particular thesis. Firstly, the LIBS technique applied on pure metals and then on samples containing the same metals in CaO matrix and the time-resolved characteristics of the plasmas produced by nsec and psec pulses were studied. Both the plasma temperature and electron density are decaying similarly and the space-averaged values determined in the nanosecond case are slightly higher than for the picosecond one. Moreover, the calibration curves obtained, show that the inherent sensitivity of the technique remains almost unaltered independently of the pulse duration. The detection limits were found to be few ppm. Then, the potentiality of LIBS method for quantitative on-line, multi-element slag analysis on plant scale was examined. Further, in order to examine more closely the produced slag, slag samples were analysed in the laboratory. The measurements were performed on solidified slag samples in a pelletized form and on as delivered solidified slag samples. The limits of the accuracy of this technique depend mainly on the laser spot/phase size ratio, the level of surface abnormalities and the distribution of each element in the matrix. The non-homogeneity level of the slag product seems to be not important in LIBS analysis, when the above ratio is quite large. It is of great importance whether the element is embedded in the matrix or in a specific crystallized phase. The influence of surface abnormalities is reduced in the case of pressed slag, but primarily for the elements distributed in the matrix, fragmentation of the slag should be avoided. The accuracy of LIBS quantitative slag analysis is strongly dependent on the standard samples that are used Regarding the liquid slag analysis, the calibration curves presented satisfactory linear dependence between the intensity of analytic lines with the corresponding concentrations while the intensity values of liquid slag appeared to be relatively increased with regard to the intensity values of solid slag under the same experimental conditions. Widening phenomena were characterized the lines of certain elements in liquid slag. For concentrations >4-5% an increased slope in calibration curves of liquid slag was observed. Finally, it was observed that each element behaves in a different way from sample in sample but also from phase in phase.
143

Développement d'un système analytique pour la datation in situ des roches martiennes par la méthode K-Ar

Devismes, Damien 08 November 2013 (has links) (PDF)
Sur Mars, la datation par comptage de densité de cratères est actuellement la seule méthode utilisée pour dater les surfaces planétaires. Cependant, sur Mars, elle n'a pas encore été corrigé et complété par des datations absolues. Ce travail consiste à développer un prototype démontrant le potentiel d'une nouvelle approche expérimentale basée sur la méthode K-Ar pour dater les roches martiennes in situ. L'objectif à terme est de proposer une solution instrumentale de datation absolue pour un futur rover d'exploration.Un laser Nd :YAG quadruplé pour tirer à 266 nm ablate un échantillon basaltique mis sous vide secondaire. L'observation du plasma par " Laser Induced Breakdown Spectroscopy " apporte des informations sur la concentration en K et sur la nature chimique et minéralogique de la cible. Puisque l'ablation est faite par un laser UV et sous vide secondaire, l'ablation est reproductible par minéralogie. La reconnaissance stoechiométrique permet donc d'estimer la masse vaporisée. Après purification des gaz libérés, un spectromètre de masse quadripolaire détermine la quantité d'argon.L'ensemble de ces mesures pourvoit un âge avec une incertitude théorique de 13% dans les meilleures conditions.Les calibrations du dispositif expérimental ont apporté de nombreuses informations sur des effets sur les spectres LIBS provoqués par l'ablation sous vide secondaire. L'augmentation de la pression e tla variation de géométrie du cratère d'ablation ont des effets opposés sur les pics des éléments.Nous avons aussi démontré que l'instrument était capable de mesurer l'âge de la mésostase de roche basaltique et qu'il offre des perspectives intéressantes sur certaines phases minérales comme la biotite.
144

Étude expérimentale et modélisation des potentialités de la technique libs (ablation laser couplée à la spectroscopie) pour l'analyse directe des solides

Barreda, Flory-Anne 09 December 2010 (has links) (PDF)
L'utilisation de lasers est largement répandue dans le domaine de la microanalyse directe des solides. La matière vaporisée, en focalisant un faisceau laser de forte puissance sur la cible, peut être analysée soit par spectrométrie d'émission optique sur plasma induit (LIBS, acronyme anglais pour Laser Induced Breakdown Spectroscopy), soit par une source à plasma induit par haute fréquence couplée à la spectrométrie d'émission optique (ICP-AES) ou à la spectrométrie de masse (ICP-MS). Avec une résolution spatiale à l'échelle microscopique, les techniques d'ablation laser permettent ainsi d'accéder à la composition élémentaire locale de la surface d'un matériau. Néanmoins, les performances analytiques de ces techniques pourraient être améliorées par l'utilisation combinée des informations LIBS et ICP afin également de comprendre et maîtriser davantage l'interaction laser/matière. Dans ce but, ce travail a consisté à développer une technique de microanalyse par ablation laser couplée avec une détection en simultané par ICP et par LIBS afin d'étudier les potentialités analytiques de cet instrument pour cartographier la surface des matériaux. Les performances et les limitations de ce système ont été évaluées d'une part, en caractérisant les aérosols produits par ablation laser et d'autre part, en étudiant les signaux LIBS et ICP obtenus à partir d'un même prélèvement de matière. Le phénomène de fractionnement élémentaire rencontré sur des matrices critiques telles que le laiton a été mis en évidence en microablation malgré des caractéristiques de l'interaction laser/matière différente de la macroablation. Une méthode de correction, a posteriori, par l'efficacité d'extraction de la cellule d'ablation a été proposée afin de pallier ces effets limitatifs pour l'analyse quantitative. Une cellule d'ablation, optimisée à partir d'une étude de simulation numérique, a été développée afin de s'adapter aux applications de cartographies de surface. Les performances analytiques du système ont été évaluées en termes de stabilité (8-10%), de résolution spatiale (5 µm) et de limites de détection (de l'ordre de la ppm dans le solide avec un détecteur de masse). La complémentarité des mesures LIBS et ICP représente à la fois un outil de diagnostic de l'interaction laser/matière et un instrument d'analyse très complet grâce à la double détection qui permet de suivre simultanément des traces et des majeurs sur une large gamme d'éléments de la classification périodique
145

Modulární systém pro prvkovou analýzu metodou laserové spektroskopie / Modular System for Elemental Analysis using Laser Spectroscopy

Klempa, Tomáš January 2015 (has links)
This diploma thesis is solved for AtomTrace Company and describes mechanical design of modular system for elemental analysis using laser spectroscopy. Object of this thesis is to create at once compact and modular system, with addition of liquid analysis module. System described in this work came out from current solution and is capable of interaction of new and previous modules. New solution is more economical both in budget and mass, whole system is fully functional and liquid analysis module with flat jet has 40 % stability, as described in experiments. The benefit of this work is possible future integration of system or separate modules into the AtomTrace portfolio and industry applications.
146

Estratégias para determinação direta de elementos químicos em amostras de macroalgas marinhas por técnicas espectroanalíticas

Brito, Geysa Barreto 17 June 2015 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-04-08T14:28:58Z No. of bitstreams: 1 tese fim colegiado.pdf: 4277452 bytes, checksum: 6964bedb598d459a8ae309af6de4f9e6 (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-10T14:24:31Z (GMT) No. of bitstreams: 1 tese fim colegiado.pdf: 4277452 bytes, checksum: 6964bedb598d459a8ae309af6de4f9e6 (MD5) / Made available in DSpace on 2016-05-10T14:24:31Z (GMT). No. of bitstreams: 1 tese fim colegiado.pdf: 4277452 bytes, checksum: 6964bedb598d459a8ae309af6de4f9e6 (MD5) / CNPq e FAPESB / Este trabalho, desenvolvido no Grupo de Pesquisa em Química Analítica da UFBA, se encontra dentro do âmbito da FAPESB, no projeto Avaliação da Poluição e Identificação de Processos de Recuperação para Regiões de Manguezais sob Influência de Atividades Industriais na Baía de Todos os Santos, e teve por objetivo o estudo e desenvolvimento de dois métodos para determinação direta de elementos químicos em macroalgas marinhas. Esses organismos estão sendo utilizadas com êxito no monitoramento da qualidade ambiental e na biorremediação de contaminação aquática. Além disso, possuem elevado valor nutricional e grande potencial na fabricação de biocombustíveis. Diante de sua importância ambiental, nutricional e energética, o estudo de sua composição mineral é importante para avaliação de potenciais aplicações e consequências. Muitos trabalhos têm sido desenvolvidos visando a determinação qualitativa e quantitativa de elementos químicos, em concentrações macro, micro e traço nas macroalgas, porém poucos são os trabalhos descritos na literatura usando métodos diretos de análise. A aplicação de métodos de análise direta de amostras sólidas é uma alternativa viável para diminuição de custos, consumo de reagentes, tempo de análise, geração de resíduos, além de minimizar a manipulação da amostra, evitando perdas de analitos e contaminação. As técnicas de fluorescência de raios X por energia dispersiva (EDXRF) e espectroscopia de emissão em plasma induzido por laser (LIBS) foram avaliadas para a determinação elementar em amostras de macroalgas marinhas. A principal dificuldade dessas técnicas para a análise direta de sólidos é estabelecer a estratégia de calibração externa, pois amostras sólidas podem ser heterogêneas, apresentar superfícies pouco uniformes, aliadas à falta de padrões compatíveis com as matrizes estudadas. Esses fatores acabam interferindo na exatidão, precisão e confiabilidade do método. Por isso, alternativas de calibração com uso de amostras de mesma matriz e análise multivariada foram aplicadas. Para verificação da eficiência das estratégias propostas, um método validado a partir de decomposição ácida de amostra assistida por radiação micro-ondas com determinação por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) foi utilizado para comparação de resultados, além do uso de sete materiais de referência certificados (CRMs) de diferentes materiais vegetais. A EDXRF possibilitou a determinação de Ca, K e Mg. Os valores de r2 dos modelos de calibração, precisão (%) para n=10, LOQ (µg g-1) e faixa de recuperação (%) em diferentes CRMs foram para: Ca (0,9233, 2,07, 109,5 e 85,0-89,3), K (0,9964, 3,82, 207,0 e 126,6-129,6) e Mg (0,9432, 4,07, 195,6 e 92,7-115,4). Por outro lado, LIBS, com uso de regressão multivariada por PLS (regressão por mínimos quadrados parciais) gerou modelos de validação com dados de número de variáveis, variáveis latentes (VLs), erro médio da validação cruzada (RMSECV, em µg g-1), r2 e faixa recuperação (%) para os CRMs de: 55, 3, 9094, 0,9174 e 124-134 (Ca); 75, 1, 4264, 0,9626 e 84-90,7 (K); 235, 1, 1315, 0,5299 e 60-4953 (Mg); e 180, 2, 2580, 0,9781 e <LQ-87,1 (Na). Com estes dados, LIBS apresentou boas previsões para Ca e K, necessitando de um melhor ajuste para Na e Mg. / This work, developed in Analytical Chemistry Research Group from UFBA, is within the scope of FAPESB, in the Assessment of Pollution and Recovery Process Identification for Mangrove Regions under the Influence of Industrial Activities in the All Saints Bay project, with the objective to study and development of two methods for direct determination of chemical elements in marine macroalgae. These organisms are being successfully used for monitoring the quality of an environment and for bioremediation of aquatic contamination. Macroalgae are also known by their nutritional value and great potential for production of biofuels. The determination of mineral composition of macroalgae is relevant taking into account their relevant applications and potential consequences. Several studies have shown the determination of macro, micro, and trace elements in macroalgae, but few studies were dedicated to their direct analysis. The application of direct solid analysis is an attractive alternative to decrease costs, consumption of reagents, sample throughput, and generation of residues. Direct solid analysis also avoids analyte losses and contamination. In the work here described, energy dispersive X-ray fluorescence (EDXRF) and laser induced breakdown spectroscopy (LIBS) were studied for elemental analysis of marine macroalgae. The main difficulty for both techniques for direct analysis of solids is the strategy for calibration, because solid samples may be heterogeneous, may have an irregular surface, and frequently there are no solid standards available considering sample matrices. These factors may affect negatively the accuracy, precision and reliability of the method. We investigated calibration strategies based on the use of same matrix and multivariate analysis. In a parallel procedure applied for comparison purposes, macroalgae samples were microwave- assisted acid digested and elemental analysis was performed by inductively coupled plasma optical emission spectrometry (ICP OES) beyond the use of seven Certified Reference Materials (CRMs) of different plant materials. It was demonstrated that EDXRF led to accurate determination of Ca, K and Mg. The r2 for the calibration models, accuracy (%) for n = 10, LOQ (µg g-1) and recovery ranges (%) at different CRMs values were to: Ca (0.9233, 2.07, 109.5 and 85.0 to 89.3), K (0.9964, 3.82, 207.0 and 126.6 to 129.6) and Mg (0.9432, 4.07, 195.6 and 92.7 to 115.4). Furthermore, LIBS, using PLS (partial least squares regression) generated validation’s models with data for number of variable, latent variables (VLs), mean error of cross validation (RMSECV in µg g-1), r2 and range recovery (%) for CRMs of: 55, 3, 9094, 0.9174 and 124 to 134 (Ca); 75, 1, 4264, 0.9626 and 84 to 90.7 (K); 235, 1, 1315, 0.5299 and 60 to 4953 (Mg); and 180, 2, 2580, 0.9781 and <LQ to 87.1 (Na). With this data, LIBS had good forecasts for Ca and K, requiring a better adjustment for Na and Mg.
147

Estratégias quimiométricas para análise de plantas por espectrometria de emissão óptica com plasma induzido por laser / Chemometric strategies for plant analysis by laser induced breakdown spectrometry

Nunes, Lidiane Cristina 08 December 2010 (has links)
Made available in DSpace on 2016-06-02T20:34:24Z (GMT). No. of bitstreams: 1 3446.pdf: 7483091 bytes, checksum: fc0625c0cc22919a8610187324efbb40 (MD5) Previous issue date: 2010-12-08 / Financiadora de Estudos e Projetos / A simultaneous optimization strategy based on neuro-genetic approach is proposed for selection of operational parameters for the simultaneous determination of macronutrients (Ca, Mg and P), micronutrients (B, Cu, Fe, Mn and Zn), Al and Si in plants by laser induced breakdown spectroscopy (LIBS). Laser pulse energy, lens-to-sample distance, number of accumulated laser pulses, delay time and integration time gate were optimized. A Q-Switched Nd: YAG laser operating in the fundamental wavelength (1064 nm) with repetition rate of 10 Hz and spectrometer with optical Echelle and ICCD detector was employed. Pellets of spinach leaves (NIST 1570a) were employed as laboratory samples. Measurements of LIBS spectra were based on three replicates and each replicate consisted of an average of ten spectra collected in different sites (i.e. test portions) of the pellet. In order to find a model that could correlate LIBS operational parameters and peak areas of all elements simultaneously a Bayesian Regularized Artificial Neural Network (BRANN) approach was employed. Subsequently, genetic algorithm (GA) was applied to find the optimal parameters for the neural network model. A single LIBS working condition pointed out by genetic algorithm (GA) was obtained with the following optimized parameters: 17.5 cm lens-to-sample distance, 25 accumulated laser pulses, 2.0 &#956;s delay time and 4.5 &#956;s integration time gate using a laser Nd:YAG at 1064 nm with 110 mJ per pulse focused on a pellet surface prepared from ground plant samples. Quantitative determinations were carried out by using chemometric methods, such as PLSR and iPLS. Samples of different cultures were used. For comparative purpose, the laboratory samples were also microwave-assisted digested and further analyzed by ICP OES. In general, results obtained by LIBS did not differ significantly from ICP OES data by applying a t-test at 95% confidence level. It is demonstrated that LIBS is a powerful tool for determination of macro and micronutrients in pellets of plant materials. / Foram desenvolvidos procedimentos quimiométricos para a determinação simultânea de P, Ca, K, Mg, P, B, Cu, Fe, Mn, Zn e Al em pastilhas de folhas de plantas por espectrometria de emissão óptica com plasma induzido por laser (LIBS). Utilizou-se um laser Q-Switched Nd:YAG a 1064 nm (pulsos de 5 ns, 10 Hz, 360 mJ). e espectrômetro com óptica Echelle e detector ICCD. Para definir as condições experimentais mais apropriadas para a determinação simultânea dos elementos, empregaram-se métodos de otimização multivariada através da abordagem neuro-genética e utilizaram-se pastilhas preparadas com o material certificado de folhas de espinafre (NIST 1570a). Dez espectros acumulados foram coletados em diferentes posições da pastilha e a média desses espectros foi utilizada como uma porção amostrada. A resposta avaliada foi área dos picos de emissão. As condições otimizadas corresponderam a 110 mJ/pulso do laser, 17,5 cm de distância entre a lente de focalização do laser e a superfície da pastilha, 25 pulsos acumulados, tempo de atraso de 2,0 &#956;s e tempo de integração de 4,5 &#956;s. Para a determinação quantitativa dos elementos, construíram-se modelos de calibração multivariada por meio da regressão dos mínimos quadrados parciais (PLSR), selecionando-se intervalos espectrais por iPLS e/ou com base no banco de dados do NIST. Para a calibração, utilizaram-se dois conjuntos de amostras, um constituído por folhas de diferentes culturas e outro por diferentes variedades de cana-de-açúcar. De modo geral, a 95% de confiança, os resultados obtidos por LIBS com emprego de PLSR apresentaram boa concordância com os valores obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Os limites de detecção estimados e os coeficientes de variação obtidos foram apropriados para análise foliar.
148

LIBS (Laser-Induced Breakdown Spectroscopy) pour l'observation martienne

Cousin, Agnès 27 January 2012 (has links) (PDF)
ChemCam est à bord de la mission Mars Science Laboratory (MSL) qui a décollé pour Mars le 26 novembre 2011. Cet instrument est très innovant car c'est la première fois que la technique du LIBS ("Laser-Induced Breakdown Spectroscopy") est utilisée pour l'exploration planétaire, afin d'étudier la géochimie des sols et roches à la surface de la planète rouge. Cette technique permet de déterminer la composition chimique de la cible analysée, en focalisant un laser à sa surface. Un plasma se créé alors par échauffement de la matière. L'analyse spectrale de la lumière émise du plasma permet d'identifier les éléments présents dans la roche, ainsi que leur concentration. Ce travail de thèse contribue à la préparation du retour scientifique de la mission MSL et de l'instrument ChemCam autour de quatre axes principaux : (i) identification et caractérisation des raies spectrales pertinentes, (ii) test des méthodes de classification des roches avec ces mesures, (iii) étude de la sensibilité aux vernis d'altération des roches ou à la couche de poussière, (iv) analyse des données pour extraire des informations sur la structure et la composition des roches. Une station sol a été développée afin d'imiter les conditions atmosphériques à la surface de Mars. Une bibliothèque de raies élémentaires a été réalisée. Cette dernière est spécifique à ChemCam et à la géochimie de Mars, et contient plus de 1300 raies. La classification des roches est efficace, quelque soit le type de cible. Les différents paramètres (distance, traitement des données, ..) pouvant influencer ces classifications ont également été caractérisés. ChemCam permet de réaliser des analyses quantitatives, que ce soit par des méthodes statistiques ou plus conventionnelles. Nous avons montré que cet instrument est capable d'analyser aussi-bien la couche d'altération d'un basalte que la roche saine au dessous. Il permet également d'effectuer des analyses très fines, comme la comparaison de différentes matrices de roches volcaniques, ou encore de la structure interne des argiles. Pour finir, ces études expérimentales réalisées durant la thèse ont démontré que ChemCam répondait à toutes les spécifications imposées au début de sa conception.
149

Formation and Quantification of Corrosion Deposits in the Power Industry

Namduri, Haritha 05 1900 (has links)
The presence of deposits on the secondary side of pressurized water reactor (PWR) steam generator systems is one of the main contributors to the high maintenance costs of these generators. Formation and transport of corrosion products formed due to the presence of impurities, metals and metallic oxides in the secondary side of the steam generator units result in formation of deposits. This research deals with understanding the deposit formation and characterization of deposits by studying the samples collected from different units in secondary side system at Comanche Peak Steam Electric Station (CPSES). Fourier transform infrared spectrophotometry (FTIR), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) have been used for studying the phases, morphologies and compositions of the iron oxides formed at Unit 1 and Unit 2 of secondary side of steamgenerator systems. Hematite and magnetite were found to be the dominant phases of iron oxides present in the units. Fe, Cr, O, Ni, Si, Cl and Cu were found in samples collected from both the units. A qualitative method was developed to differentiate iron oxides using laser induced breakdown spectroscopy (LIBS) based on temporal response of iron oxides to a high power laser beam. A quantitative FTIR technique was developed to identify and quantify iron oxides present in the different components of the secondary side of the steam generator of CPSES. Amines are used in water treatment to control corrosion and fouling in pressurized water reactors. CPSES presently uses an amine combination of dimethylamine (DMA), hydrazine and morpholine to control the water chemistry. Along with the abovementioned amines, this study also focuses on corrosion inhibition mechanismsof a new amine DBU (1, 8-diazabicyclo [5.4.0] undec-7-ene). Electrochemical impedance spectroscopy and polarization curves were used to study the interaction mechanism between DBU solution and inconel alloys 600 and 690 at steamgenerator operating temperatures and pressures. Of all the amines used in this study (DMA, DBU, ETA, and morpholine), DMA was more effective at keeping the passive film formed on the alloy 600 surface from failing at both ambient and high temperatures. Morpholine was found result in higher corrosion resistance compared to the other amines in case of alloy 690.
150

Nouvelle utilisation de l’ablation laser dans l’analyse de pétrole et de ses dérivés

Martinez Labrador, Mauro Alberto 21 January 2013 (has links)
L’analyse du pétrole et de ses dérivés est d'une grande importance pour l'industrie pétrolière et de l'environnement, et que dans sa matrice contient un ensemble de métaux (V, Ni, Fe, etc) et les non-métaux (S, N, Cl, etc) qui ont un grand impact au cours du raffinage et des procédés de combustion. La quantification de ces éléments est devenu sujet commun dans de nombreux laboratoires d'analyse. À l'heure actuelle, il existe des méthodes standard pour la quantification de ces éléments à l'aide des techniques spectroscopiques telles que la plasma à couplage inductif (ICP), la vaporisation électrothermique (ETV), analyse par activation neutronique (NAA), des métaux et des non-métaux, et des techniques potentiométriques les non-métaux tels que les halogènes. Ces méthodes, bien qu'elles soient validées, montrent des formalités fastidieuses, vous pouvez demander stratégies d’étalonnages bons et, dans certains cas, nécessite l'utilisation de normes coûteuses organométalliques. En raison de ces raisons a été soulevée dans le présent document rechercher de nouvelles formes de dosage pour l'analyse élémentaire dans le pétrole et ses dérivés en utilisant des méthodologies sensibles, rapides et faciles. La première idée qui se pose est de l'échantillon enrobé dans une matrice de xérogel de solide brut, ce qui pose le profit pour préparer les normes d'étalonnage à l'aide de solutions aqueuses de concentration connue et en les encapsulant dans la même manière. Cette huile manière encapsulée dans xérogel a été validée à l'aide LA ICP-MS et LIBS et les limites de détection ont été obtenus à partir de 0,7 ng g-1 pour Ni, 0,8 ng g-1 pour V et 1,5 ng g- 1 S, avec une reproductibilité entre 1 à 3%. L'analyse de spéciation ont également soulevé des molécules associées à V, Ni et S par chromatographie sur couche mince et surveillés par MS PCI ainsi trouvé une famille de différenciation molécules associées à ces éléments entre différentes fractions de pétrole brut et la matrice de l'échantillon même que les limites de détection ont été trouvés pour Ni et V de 18 ng g-1 et 23 ng g-1 respectivement. Il a également été observé que l'utilisation de ces méthodes d'analyse peut prendre moins de temps pour atteindre certains protocoles d'analyse systématique et finalement échouer à générer très peu de déchets dans l'environnement. / Analysis of crude oil and its derivatives is of great importance for the crude oil industry and the environment, and that within its matrix contains a set of metals (V, Ni, Fe, etc.) and nonmetals (S, N, Cl, etc) which have great impact during the refining and combustion processes. Quantification of these elements has become common subject matter in many analytical laboratories. Currently, there are standard methods for the quantification of these elements using spectroscopic techniques such as inductively coupled plasma (ICP), electrothermal vaporization (ETV), neutron activation analysis (NAA), for metals and some non-metals, and potentiometric techniques non-metals such as halogens. These methods, although they are validated, show time-consuming procedures, it can not raise a good calibration strategies and in some cases requires the use of expensive organometallic standards. Because of these reasons was raised in this paper find new forms of quantification for elemental analysis in the oil and its derivatives using sensitive methodologies, quick and easy. The first idea that arises is the sample encapsulated within a crude solid xerogel matrix, this poses the advantage to prepare our own calibration standards using aqueous solutions of known concentration and encapsulating them in the same way. This way crude oil encapsulated in xerogel was validated using LA ICP MS and LIBS and detection limits were obtained from 0.7 ng g-1 for Ni, 0.8 ng g-1 for V and 1.5 ng g-1 S, with a reproducibility between 1 to 3%. Also raised speciation analysis of molecules associated with V, Ni and S by thin layer chromatography and monitored by LA ICP MS, thus was found a family of differentiation-associated molecules to these elements between different fractions of crude and the same sample matrix, as detection limits were found for Ni and V of 18 ng g-1 and 23 ng g-1 respectively. It was also observed that the use of these methods of analysis may take less time to reach some systematic analysis protocols and ultimately fail to generate very little waste to the environment.

Page generated in 0.9095 seconds