• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 1
  • Tagged with
  • 76
  • 76
  • 48
  • 33
  • 22
  • 18
  • 17
  • 15
  • 14
  • 13
  • 13
  • 12
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Análise da eficiência e confiabilidade em 56 estações de tratamento de esgotos localizadas na região metropolitana de Fortaleza / Analysis of efficiency and reliability in 56 sewage treatment plants located in the metropolitan area of Fortaleza

Monteiro, Carlo Rannyêr Lopes 27 August 2009 (has links)
MONTEIRO, C. R. L. Análise da eficiência e confiabilidade em 56 estações de tratamento de esgotos localizadas na região metropolitana de Fortaleza. 2009. 77 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-22T17:31:11Z No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-29T14:51:15Z (GMT) No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) / Made available in DSpace on 2016-04-29T14:51:15Z (GMT). No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) Previous issue date: 2009-08-27 / Many Wastewater Treatment Plants (WWTPs) have serious design and / or operational problems that decrease efficiency levels and pollute the environment. Thus, it is important to have efficient and reliable WWTPs to meet the discharge standards. The purpose of this study was to analyze the efficiency and reliability of 56 wastewater treatment plants located in the Metropolitan Region of Fortaleza (MRF). About 13,100 data were evaluated, which were obtained from the Company of Water and Wastewater of Ceará (CAGECE). The data were from January 2005 to April 2009, divided in nine treatment technologies: septic tank (ST), septic tank followed by anaerobic filter (ST + ANF), septic tank followed by anaerobic filter and chlorination (ST + ANF + Cl), facultative pond (FP), facultative pond followed by a maturation pond (FP + MP), anaerobic pond followed by facultative pond and maturation pond (ANP + FP + MP), facultative aerated pond followed by facultative pond and maturation pond (FAP + FP + MP), UASB reactor (UASB) and finally UASB reactor followed by chlorination (UASB + Cl). To calculate the reliability of WWTPs and expected attendance percentage to accomplish effluent standards, a log-normal distribution was used. The average concentrations that the effluent from WWTP must have to meet the discharge standard were calculated for a given reliability level (95%), taking into account the coefficient of reliability (COR). The affluent values of pH, COD, TSS and TTC were compared to those typically found for this type of wastewater. The initial data analysis indicated problems in the monitoring frequency, inconsistencies and outliers, which were removed. The resulting data were used afterwards. The average efficiency values obtained in some technologies are lower than those of comparative literature, indicating operational problems. The highest efficiency values for COD, TSS and TTC were achieved with the technologies of ANP + FP + MP (91,4%), ANP + FP + MP (81.0%) and FAP + FP + MP (99.999%); the lowest efficiencies were obtained with ST + ANF (47.3%), ST (31.6%) and FP (95.36%), respectively. Regarding the coefficient of reliability calculation, the highest values for COD removal were obtained with the technologies of FAP + FP + MP (0.57) and UASB (0.57) and the lowest efficiencies were found with DD + ANF + Cl (0.40). For TSS, the best technologies were FAP + FP + MP (0.43) and FP (0.41) while the lowest CORs were obtained with ANP + FP + MP (0.26). The highest percentage values for accomplishing COD discharge standards were achieved with stabilization ponds, all above 98%, specially the technology FAP + FP + MP (99.9%). For TSS the highest percentages were also achieved with stabilization ponds, highlighting the technology of ANP + FP + MP (91%). The technologies of FAP + FP + MP and ANP + FP + MP provided the best efficiency values for COD, TSS and TTC, as well as the highest values of COR and percentages to accomplish discharge standards. / Diversas estações de tratamento de esgoto possuem sérios problemas de projeto e / ou operacionais os quais prejudicam o seu processo de tratamento e geram riscos de poluição dos recursos hídricos receptores. Assim, há a necessidade de tratamentos de esgotos cada vez mais eficientes e confiáveis para obedecerem aos padrões de descarte definidos em legislações ambientais cada vez mais restritivas. O objetivo do presente estudo foi analisar a eficiência e a confiabilidade de 56 estações de tratamento de esgotos situadas na Região Metropolitana de Fortaleza (RMF). Para tanto, foram avaliados cerca de 13.100 dados obtidos do monitoramento dos esgotos afluente e efluente às ETEs, durante o período de janeiro de 2005 a abril de 2009, as quais foram divididas em nove modalidades de tratamento, quais sejam: decanto-digestor (DD), decanto-digestor seguido de filtro anaeróbio (DD+FAN), decanto-digestor seguido de filtro anaeróbio e cloração (DD+FAN+Cl), lagoa facultativa (LF), lagoa facultativa seguida de lagoa de maturação (LF+LM), lagoa anaeróbia seguida por lagoa facultativa e lagoa de maturação (LAN+LF+LM), lagoa aerada facultativa seguida por lagoa facultativa e lagoa de maturação (LAF+LF+LM), reator UASB (UASB) e, por fim, reator UASB seguido de cloração (UASB+Cl). Para o cálculo da confiabilidade das ETEs e do percentual esperado de atendimento aos padrões de lançamento foi utilizada uma metodologia baseada em um modelo de distribuição log-normal dos dados, a qual determina concentrações médias que o efluente da ETE deve ter para obedecer aos padrões ambientais de lançamento para um determinado nível de confiabilidade (95%), levando em consideração o coeficiente de confiabilidade (CDC). Os valores afluentes de pH, DQO, SST e CTT foram comparados aos que são tipicamente encontrados para esse tipo de esgoto. Na avaliação inicial dos dados observou-se não haver freqüência de monitoramento, bem como, constatou-se a presença de inconsistências e outliers, os quais foram removidos. Os dados resultantes foram utilizados na seqüência da análise. Várias tecnologias de tratamento tiveram valores de eficiência inferiores ao que é registrado na literatura, indicando falhas operacionais no monitoramento das ETEs. Os maiores percentuais médios de remoção de DQO, SST e CTT foram alcançados pelas modalidades LAN+LF+LM (91,4%), LAN+LF+LM (81,0%) e LAF+LF+LM (99,999%) e os menores foram DD+FAN (47,3%), DD (31,6%) e LF (95,36%), respectivamente. Estes resultados mostram-se condizentes com os encontrados na literatura para todas as tecnologias de tratamento, exceto para remoção de SST por DD (31,6%) e DD+FAN (37,3%). No que se refere ao cálculo do coeficiente de confiabilidade foram obtidos para DQO os maiores valores pelas modalidades LAF+LF+LM (0,57) e UASB (0,57) e o menor valor para DD+FAN+Cl (0,40). Já para SST as tecnologias que se destacaram foram LAF+LF+LM (0,43) e LF (0,41) enquanto que o menor CDCs foi obtido por LAN+LF+LM (0,26). Os maiores percentuais esperados de atendimento às metas de descarte para DQO foram alcançados pelos tratamentos compostos por lagoas de estabilização, todos acima de 98%, destacando-se a tecnologia LAF+LF+LM (99,9%). Para SST os maiores percentuais obtidos também foram para as lagoas de estabilização, ressaltando a tecnologia LAN+LF+LM (91%). A tecnologia de tratamento DD foi a de menor percentual para DQO (1,2%) e para SST (2,0%). As modalidades de tratamento de esgotos domésticos LAF+LF+LM e LAN+LF+LM apresentaram um melhor desempenho considerando as eficiências médias de remoção de DQO, SST e CTT, como também maiores valores de CDC e percentuais esperados de atendimento às metas estabelecidas pela legislação.
52

Análise de incertezas e de sensibilidade e avaliação quantitativa de risco microbiológico aplicadas ao dimensionamento de lagoas de polimento e à utilização de efluentes para irrigação / Uncertainty and sensitivity analyses and quantitative microbial risk analysis apllied to polishing ponds design and to wastewater use for irrigation

Pavione, Damares Mirian de Souza 22 March 2010 (has links)
Made available in DSpace on 2015-03-26T13:27:56Z (GMT). No. of bitstreams: 1 texto completo.pdf: 7394685 bytes, checksum: aeb9cc781b146a08d4feda43890a0a42 (MD5) Previous issue date: 2010-03-22 / This work presents the characterization and analysis of a database from an approximately seven-year period monitoring of a domestic wastewater treatment system composed of a UASB reactor, a submerged aerated biofilter (field scale) and a polishing pond series (pilot scale). The following variables were analyzed: BOD, COD, TSS, N-NH3, total phosphorus, pH, E. coli, total coliforms and helminth eggs. The hypothesis of data randomness, stationarity and homogeneity were, in general, confirmed, but data independency was not. Most data presented skewness and kurtosis different from those of the normal distribution. The results suggest that the lognormal function well represented the data distribution of BOD, COD, TSS, N-NH3, pH, E. coli, and total coliforms. Total phosphorus was better characterized by normal distribution, but the helminth eggs data could not be successfully adjusted to a distribution model. The lognormal distribution was applied to pH, pH, N-NH3 and E. coli data as input variables in stochastic modeling (Latin hypercube sampling at 10,000 iterations) for the prediction of pond effluent quality. It is suggested that a three-pond series is sufficient to achieve an effluent discharge standard of 20 mg N-NH3 L-1, as well as the WHO guidelines, in terms of E.coli/100 mL, for the irrigation of leaf and root crops. The use of the lognormal distribution for the pond influent values of E. coli, N-NH3 and pH resulted in effluent concentrations significantly different from those when using the uniform distribution. Sensitivity analysis indicated that E.coli concentration and the bacterial decay coefficient were the input variables which had the greatest effect on the output estimates of E.coli concentrations. The estimates of N-NH3 in pond effluents were influenced mostly by the N-NH3 influent and the pH values. These results point out that pH values and the bacterial decay coefficient should be carefully chosen for an adequate pond design. Finally, in order to estimate infection risks arising from the consumption of wastewater-irrigated salad crops, the pond s bacterial effluent quality database was used in quantitative microbial risk analysis models. Using stochastic modeling (Latin hypercube sampling at 10,000 iterations), assuming the E.coli data according to a lognormal distribution, and a tolerable risk level of 10-3 pppy, effluent quality standards of 103 and 104 E. coli/100 mL were shown to be adequate for the irrigation of, respectively, high- and low-growing crops. The use of the lognormal distribution, instead of a uniform distribution, resulted in risk estimates significantly lower. Sensitivity analysis indicated that the pathogens: E.coli ratio and pathogen reduction between crops harvesting and consumption were the input variables which had the greatest effect on risk estimates, pointing out the need for reliable information on these variables. / Este trabalho apresenta a caracterização e análise de um banco de dados relativo à cerca de sete anos de monitoramento de um sistema de tratamento de esgotos sanitários constituído por reator UASB, biofiltro submerso aerado (escala real) e lagoas de polimento (escala piloto). Foram analisadas as seguintes variáveis: DBO, DQO, SST, N-NH3, fósforo total, pH, E. coli, coliformes totais e ovos de helmintos. As hipóteses de aleatoriedade, estacionariedade e homogeneidade dos dados foram, em geral, confirmadas, mas a de independência não. A maioria das séries de dados apresentou características de assimetria e curtose distintas da distribuição normal. Os resultados sugerem que a função lognormal melhor descreveu a distribuição dos dados de E. coli, coliformes totais, pH, SST, DBO, DQO e N-NH3. Os dados de fósforo apresentaram melhor adesão ao modelo normal de distribuição. Quanto aos ovos de helmintos, não foi possível identificar uma distribuição que mais nitidamente se ajustasse ao banco de dados disponível. A distribuição lognormal foi aplicada às variáveis de entrada pH, N-NH3 e E. coli em modelagem estocástica (amostragem aleatória por hipercubos latinos com 10.000 iterações) para a previsão da qualidade de efluentes de lagoas de polimento. Constatou-se que uma série de três lagoas parece ser suficiente para o alcance de 20 mg N-NH3 L-1 como padrão de lançamento de efluentes, e para atender as recomendações da OMS em termos de concentração de E. coli para a irrigação de hortaliças folhosas, raízes e tubérculos. O uso da distribuição lognormal para as concentrações afluentes de E. coli, N-NH3 e valores de pH resultaram em concentrações efluentes de E. coli e N-NH3 significativamente diferentes em relação ao uso da distribuição uniforme. Testes de análise de sensibilidade indicaram que as variáveis de maior impacto na previsão da concentração efluente de E. coli foram a concentração afluente de E. coli e o coeficiente de decaimento bacteriano. Na previsão da concentração efluente de N-NH3, as variáveis de maior impacto foram a concentração afluente de N-NH3 e os valores de pH. Os resultados indicam, portanto, a necessidade de escolha criteriosa de valores de pH e de coeficiente de decaimento bacteriano para o dimensionamento de lagoas de polimento. Por fim, para efeito de estimativa de riscos de infecção decorrentes da irrigação de hortaliças ingeridas cruas, os dados de qualidade bacteriológica dos efluentes das lagoas foram utilizados em modelos de avaliação quantitativa de risco microbiológico. Por meio de modelagem estocástica (amostragem aleatória por hipercubos latinos com 10.000 iterações), assumindo distribuição lognormal para a concentração de E. coli e nível de risco tolerável de 10-3 pppa, padrões de 103 e 104 E. coli/100 mL pareceram adequados para a irrigação de hortaliças que se desenvolvem, respectivamente, rentes ao e distantes do solo. O uso da distribuição lognormal resultou em estimativas de risco significativamente menores que o uso da distribuição uniforme. Análise de sensibilidade apontou a relação patógenos/E. coli e a redução de patógenos entre a colheita e o consumo como as variáveis de maior impacto na estimativa de risco, indicando a necessidade de dados confiáveis desses parâmetros.
53

Comportamento de variáveis físicas, químicas e da eficiência de sistemas de lagoas de estabilização em ambiente tropical (Vale do Ribeira de Iguape, SP) / Behavior of physical, chemical variable and efficiency of systems composed by stabilization ponds in tropical environment (Vale Ribeira de Iguape, SP, Brazil)

Ana Flávia da Silva Hoeppner 20 August 2007 (has links)
As lagoas de estabilização compõem sistemas de tratamento de águas residuárias sujeitos à variação de eficiência decorrente, dentre outros fatores, das variações climáticas. A variação de eficiência e da estratificação em lagoas de estabilização, localizadas em ambiente subtropical, em diferentes épocas do ano, foi o principal objetivo dessa pesquisa. Para essa finalidade, a eficiência de dois sistemas de lagoas de estabilização localizadas no Vale do Ribeira de Iguape (SP) - nas cidades de Jacupiranga e Pariquera-Açu - foi determinada, em período sazonal (quatro épocas do ano) e semanal (três dias consecutivos), assim como perfis de temperatura, condutividade elétrica, pH e oxigênio dissolvido e aspectos ambientais (temperatura do ar, radiação solar, direção e velocidade do vento e precipitação) foram mensurados. Além disso, aspectos operacionais, tais como, volume de lodo, de água, vazão e tempo de detenção teórico foram mensurados a fim de caracterizar apenas as lagoas facultativas. Alterações no comportamento sazonal destas variáveis e padrões de similaridade entre eficiência de cada lagoa e estratificação térmica foram analisadas através da ferramenta estatística análise do componente principal (PCA). Observou-se, principalmente, que a variação sazonal de eficiência foi relevante, sendo que, em julho/06 a qualidade do afluente e do efluente foi diferente das outras épocas do ano, ou seja, houve variação sazonal de variáveis físicas e químicas. Variação diária foi observada em janeiro/06, época de maiores precipitações e maior homogeneidade térmica. Na PCA, a estratificação térmica foi significativa, ou seja, esteve relacionada com outras variáveis. A vazão e tempo de detenção, nas lagoas facultativas, estiveram dentro de faixas observadas em outras lagoas de estabilização e o volume de lodo não ultrapassou 3% do volume das lagoas. / Stabilization ponds compose systems of wastewater treatment citizens to the variation of efficiency decurrent, amongst other factors, of the climatic variations. The variation of efficiency and stratification in stabilization ponds, located in subtropical environment, at different seasons, was the main objective. For this purpose, the efficiency of two stabilization ponds systems located in the Vale do Ribeira de Iguape (SP) - in cities as Jacupiranga and Pariquera-Açu - was determined, in sazonal period (four seasons) and weekly (three days consecutive), as well as temperature, electric condutivity, pH and dissolved oxygen profiles and environment aspects had been measured (air temperature, solar radiation, direction and speed of the wind and precipitation). Moreover, operational aspects, such as, volume of sludge, volume of water, outflow and theoretical detention times had been measured in order to characterize only the facultative ponds. Alterations in sazonal behavior of these variables and standards of similarity between efficiency and thermal stratification had been analyzed through the tool statistics análise do componente principal (PCA). It was observed, mainly, that the sazonal variation of efficiency was important, so, in July/06 the quality of the affluent and effluent was different to the other seasons, in other words, it was observed sazonal variation of physical and chemical variable. Daily variation happened in January/06, time of more precipitations and thermal homogeneity. In other analysis with PCA, the thermal stratification was significant and it was related with other variable. The outflow and detention times, in the facultative ponds, had been similar others facultatives ponds and the volume of sludge did not exceed 3% of the volume of water in the ponds.
54

Interferências da codisposição de resíduos de fossa e tanque séptico em sistemas de lagoas anaeróbias seguidas de facultativas aeradas - Estudo de caso para a ETE- Anápolis / Interference of co-disposing of wastes from cesspool and septic tanks into anaerobic ponds followed by aerated facultative

Oliveira, Getúlio Henrique de 19 July 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-10-22T19:58:08Z No. of bitstreams: 2 Dissertação - Getúlio Henrique de Oliveira- 2013.pdf: 2643219 bytes, checksum: 04fc7d8dc87b43e20032d6e2cb521968 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-22T20:28:09Z (GMT) No. of bitstreams: 2 Dissertação - Getúlio Henrique de Oliveira- 2013.pdf: 2643219 bytes, checksum: 04fc7d8dc87b43e20032d6e2cb521968 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-22T20:28:09Z (GMT). No. of bitstreams: 2 Dissertação - Getúlio Henrique de Oliveira- 2013.pdf: 2643219 bytes, checksum: 04fc7d8dc87b43e20032d6e2cb521968 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-07-19 / The study aimed to assess the impact caused by the waste discharge from cesspools and septic tanks into an anaerobic pond, followed by aerated facultative. Anápolis wastewater treatment plant (WWTP) has two modules of anaerobic ponds followed by aerated facultative, but only one received the waste. By going through a basket retainer of course solids, they were driven directly to the receiver module ponds. The research was divided into three steps: first of all, the system receiving the waste in both modules was evaluated with the rate application volume (RAV) of 0.33%, then, the receiving pond received all of the waste volume disposed in WWTP (RAV = 1.2%), finally the receiving pond was operated with the maximum organic loading and RAV = 0,83%. Samples from different septic tank cleaning trucks were collected and analyzed. Sludge deposited bathymetry was conducted in the anaerobic pond before and after isolation of the modules. The surface scum bulk in the anaerobic pond was removed and quantified. Initially, simple samples were collected from the influent and effluent of anaerobic and facultative aerated ponds weekly, and then, when the receiver module received double flow, samples were collected twice a week. Parameters analyzed were: BOD, COD, Escherichia coli, pH, oil and grease, total phosphorus, amonniacal nitrogen, suspended solids and settleable solids. Data from qualitative characterization of waste cesspools and septic tanks were submitted to descriptive statistics, while referring to the ponds effluents were analyzed by t-test statistical tool. The results indicated the characteristics of the waste are in the range found by other authors, both in national and international literature. A negative impact was evidenced on the receiving anaerobic pond effluent only for the parameters ammonia and settleable solids with the RAV of 1.2%, however, with the rate of 0.82%, the difference was significant for the parameters BOD and BOD in anaerobic ponds. There was an increase in sludge generation of approximately 16% in the receiving anaerobic pond and only 2.3% in the control. As for the scum, the average removal was approximately 450 L in the receiving anaerobic pond and only 100 L in the control. The results showed no effect of the co-treatment on the quality of treated sewage or in the operation and maintenance of the WWTP. Furthermore, systems formed by an anaerobic pond followed by facultative aerated, operating under the same conditions that Anápolis WWTP can be used for co-treatment of waste from cesspools and septic tanks / O estudo teve como objetivo avaliar os impactos da codisposição de resíduos de fossas e tanques sépticos em sistemas de lagoas anaeróbias seguidas de facultativas aeradas. A ETE estudada é composta por dois módulos idênticos de lagoas anaeróbias seguidas de facultativas aeradas, porém apenas um deles recebeu os resíduos. Ao passar por um cesto retentor de sólidos grosseiros, os mesmos foram conduzidos diretamente ao módulo receptor de lagoas. A pesquisa foi dividida em três etapas; primeiramente foi avaliado o sistema recebendo os resíduos em ambos os módulos de lagoas, com taxa de aplicação volumétrica (TAV) de 0,33%, posteriormente, a lagoa receptora recebeu todo o volume de resíduos descartado na ETE (TAV = 1,2%), por fim, a lagoa receptora foi operada com a capacidade máxima de carga orgânica e TAV de 0,83%. Amostras provenientes de diferentes caminhões limpa-fossa foram coletadas e analisadas. Realizou-se a batimetria do lodo depositado nas lagoas anaeróbias antes e depois do isolamento dos módulos. A escuma formada na superfície das lagoas anaeróbias foi removida e quantificada. Inicialmente, coletou-se amostras simples do afluente e efluente das lagoas anaeróbias e facultativas aeradas em uma frequência semanal, posteriormente, quando o módulo receptor passou a receber o dobro de vazão, as coletas foram realizadas duas vezes na semana. Foram avaliados os parâmetros de DBO, DQO, Escherichia coli, pH, óleos e graxas, fósforo total, nitrogênio amoniacal, sólidos suspensos, sólidos sedimentáveis. Os dados de caracterização qualitativa dos resíduos de fossas e tanques sépticos foram submetidos à estatística descritiva, enquanto os referentes ao efluente das lagoas foram analisados pela ferramenta estatística teste t. Os resultados indicaram que as características dos resíduos estão na faixa encontrada por outros autores, tanto na literatura nacional, quanto internacional. Foi evidenciado impacto negativo no efluente da lagoa anaeróbia receptora somente para os parâmetros nitrogênio amoniacal e sólidos sedimentáveis com a TAR de 1,2%, entretanto, com a taxa de 0,82%, observou-se diferença significativa para os parâmetros DBO e DBO nas lagoas anaeróbias. Notou-se aumento na geração de lodo de aproximadamente 16% na lagoa anaeróbia receptora e de apenas 2,3% na testemunha. Quanto a escuma, a remoção média foi de aproximadamente 450 L na lagoa anaeróbia receptora e de apenas 100 L na testemunha. Os resultados mostraram que a codisposição não interferiu na qualidade do esgoto tratado nem na operação e manutenção da ETE. Além do mais, sistemas formados por lagoa anaeróbia, seguida de facultativa aerada, operando nas mesmas condições que a ETE - Anápolis, podem ser utilizadas para a codisposição de resíduos provenientes de fossa e tanques sépticos.
55

Avaliação das interferências da disposição de resíduos de fossas e tanques sépticos em lagoas de estabilização que tratam lixiviados: estudo de caso para o aterro sanitário de Anápolis (GO) / Evaluation of septage disposal in stabilization ponds that treat landfill leachate: case of study to the Anapolis' landfill

Carrilho, Samara Monayna Alves Vasconcelos 20 March 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-11-03T16:48:26Z No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-11-03T16:49:41Z (GMT) No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-03T16:49:41Z (GMT). No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-03-20 / The destination of septage has resulted in environmental and public health problems, due especially to the lack of adequate alternatives for its destination and of closer, more rigorous monitoring. The problem worsens in areas lacking sewage treatment plants, since the disposal in such systems has been the most widely used practice in the country. In this way, the current research aims to evaluate the effects of the sludge disposal in the performance, operation and maintenance of treatment plant of leachate from landfill of Anápolis (GO). The characterization of the municipality RST was also performed by analyzing of twelve composite samples, each one from five vacuum trucks. It was evaluated the system consists of two identical modules, one it was the control group and another one received the RST. This module was submitted, increasingly, to differents Rate Volumetric Application (RVA) of RTS. Thus, the study was divided into five phases, starting with RVA of 13 % up to 204 %. Various parameters (BOD, COD, pH, oil and grease, total phosphorus, ammoniacal nitrogen, suspended solids, settling solids and Escherichia coli) were analyzed for the samples from the influent and effluent of the anaerobic and facultative ponds. It was also evaluated the impact on the maintenance and operation in the system plant, by measuring the height of the sludge in anaerobic lagoon and quantification of scum formed on the surface anaerobic pond. In facultative ponds it was performed by raising the phytoplankton community, ordering to identify possible interference in the richness and abundance of algae and cyanobacteria in these ponds. The data were statistically analyzed by the Studentt test, and the results indicated that until to 18 % of RVA there were no significant changes in the quality of treated leachate (effluent of stabilization ponds). Since the RVA of 35 % was detected a significant difference in the concentration of E. coli and ammoniacal nitrogen in treated effluent (p < 0.05). At the RVA of 204% the concentration of phosphorus in the final effluent from facultative pond increased. There was an increase in sludge generation of 266% in the receiving anaerobic pond and only 38% in the control anaerobic pond. In addition, there was a thick layer of scum only on the surface of the receiving anaerobic pond. The phytoplankton community of facultative ponds was similar and presented low diversity. The Chlorella genera were dominant in both lagoons. From the results of this study, it is recommended the conjugate treatment of RFTS and leachate in stabilization ponds systems, because even applying RVA of 204%,the final effluent don’t have concentrations higher than those stipulated by CONAMA Resolution 430/2011. / A destinação dos Resíduos de Fossa e Tanque Séptico (RFTS) tem resultado em problemas ambientais e de saúde pública, devido principalmente à falta de alternativas adequadas para a destinação, e de fiscalização mais rigorosa. O problema se agrava em municípios desprovidos de estações de tratamento de esgoto, já que a disposição nesses sistemas tem sido a prática mais utilizada no país. Neste contexto, a presente pesquisa teve por finalidade avaliar as possíveis interferências da disposição dos RFTS no desempenho, operação e manutenção no sistema de tratamento de lixiviados do Aterro Sanitário de Anápolis (GO). Também foi realizada a caracterização dos RFTS do município, através da análise de doze amostras compostas, cada uma proveniente de cinco caminhões limpa-fossas. Avaliou-se o sistema composto por dois módulos idênticos, sendo um testemunho e outro receptor de RFTS. Este foi submetido, de forma crescente, a diferentes Taxas de Aplicação Volumétrica (TAV) de RFTS, iniciando com TAV de 13%, até chegar a TAV de 204%. O estudo foi executado e os parâmetros físico-químicos e microbiológicos (DBO, DQO, pH, OG, fósforo total, nitrogênio amoniacal, sólidos suspensos, sólidos sedimentáveis e Escherichia coli) de amostras simples do afluente e efluente das lagoas anaeróbias e facultativas de ambos módulos foram analisados. Nas lagoas anaeróbias verificaram-se os possíveis impactos na manutenção e operação do sistema, através da medição da altura do lodo sedimentado no fundo da lagoa e da quantificação da escuma formada em sua superfície. Nas lagoas facultativas realizou-se o levantamento da comunidade fitoplanctônica, visando identificar possíveis interferências da codisposição de RFTS na riqueza e abundância de algas e cianobactérias. Os dados obtidos foram tratados estatisticamente, através do teste t the Student, e os resultados indicaram que até a TAV de 18% não houve alterações significativas na qualidade do lixiviado tratado (efluente das lagoas de estabilização). A partir da TAV de 35% detectou-se diferença significativa na concentração de E. coli e nitrogênio amoniacal no efluente tratado (p<0,05) e para a TAV de 204% ocorreu aumento na concentração de fósforo no efluente final da lagoa facultativa receptora. Houve interferência na manutenção e operação das lagoas, com aumento de 266% na altura do lodo sedimentado da lagoa anaeróbia receptora, ao passo que na lagoa anaeróbia testemunha, o aumento foi de 38%. Densa camada de escuma formou-se apenas na superfície da lagoa anaeróbia receptora. A comunidade fitoplanctônica das lagoas facultativas apresentou baixa diversidade, com predominância de algas do gênero Chlorella. Os resultados indicaram alta variabilidade dos RFTS do município de Anápolis. A partir deste estudo, recomenda-se o tratamento conjugado de RFTS e lixiviados em sistemas de lagoas de estabilização, pois mesmo aplicando alta TAV (204%), o efluente final não contrariou o padrão de lançamento proposto pela Resolução CONAMA 430/2011.
56

Bioensaio toxicológico com cianobactérias do efluente da lagoa de estabilização e do Igarapé Grande, Boa Vista, Roraima

Eliana Fernandes Furtado 28 March 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A pesquisa teve o objetivo de averiguar a presença de toxicidade nas cianobactérias planctônicas no deságue da Lagoa de estabilização no igarapé Grande, em Boa Vista, por meio de bioensaio em camundongos de linhagem Swiss albino. O corpo hídrico em estudo está localizado na área urbana de Boa Vista, recebe influência resultante da descarga final dos esgotos domésticos dos moradores próximos e de efluentes do sistema de tratamento de esgotos sanitários da cidade, apresentando florações em alguns trechos. Pesquisas anteriores constataram a presença de florações de cianobactéria planctônica nesse ambiente. No entanto, havia a ausência de estudos sobre a toxicidade das florações de cianobactéria planctônicas existentes no igarapé Grande. A área escolhida foi georeferenciada e denominada como: E1 (montante do deságue da ETE), situada no igarapé grarde; E2 (desague/calha); E3 (jusante do deságue). Foram realizadas três coletas amostrais no período seco e três no período das chuvas. No momento da coleta, foram feitas medidas do pH e temperatura da água. Em seguida, foram realizadas as análises das concentrações de clorofila-a, nitrogênio amoniacal, fósforo total, turbidez e estimativa de densidade celular. Foi observado a presença de cianobactérias da espécie Planktothrix agardhii (Gomont) Anagnostidis et Komárek durante todos os meses de coletas, nos períodos sazonais (seco e chuvoso) e confirmou-se que a Estação de Tratamento de Esgoto Sanitário do município de Boa Vista ETE/BV - é a fonte de entrada dessa espécie de cianobactéria no igarapé Grande. Foi observada a distribuição dos organismos na superfície da água afetando a qualidade físico-química do igarapé Grande. Também o teste estatístico possibilitou a identificação da amônia (NH3) como a variável de maior contribuição para a toxicidade nas estações. Além disso, o resultado foi ratificado pelos testes quimiométricos PCA; FA. O teste (DL50 -24 horas), realizado por meio de bioensaio em camundongos no período seco, do material algáceo da estação E3, apresentou a toxicidade em doses acima de 2.500 mg kg mL- (p.c), com a maior mortalidade de 75% dos indivíduos do grupo que recebeu as concentrações de 100 mg mL-. Os resultados da estação de coleta E2, mostram mortalidade de 25% dos indivíduos na concentração de extrato de 50 mg mL-, 25% de indivíduos e 100 mg mL- dos individuo e 75% de indivíduos com a concentração de 150 mg mL- das amostras coletadas durante o período das chuvas. / The study aimed to access the presence of toxic planktonic cyanobacteria by mouse bioassay in the outflow of the stabilization pond and in the Igarapé Grande, Boa Vista, RR. The waterbodies under study are located in the urban area of Boa Vista, and are influenced by the final discharge of the domestic sewage from nearby residents and effluents of the sewage treatment plant from the city. Previous research has established the presence of cyanobacterial blooms in this environment. However, there was a lack of studies on the toxicity of the cyanobacteria that bloom in the stabilization pond system and adjacent Igarapé Grande. The study area was geo-referenced and named as E1 (upstream of the sewage treatment plant outflow), located in the Igarapé Grande, E2 (outflow/gutter), and E3 (downstream of the outflow), also in the Igarapé Grande. It was performed three sample collections during the dry season and three during the rainy season. At the time of the samplings measurements of pH and water temperature were carried out. It was also collected samples for the estimation of chlorophyll-a, ammonia nitrogen, total phosphorus, turbidity and cell density evaluation. We observed the presence of the cyanobacteria of the genus Planktothrix agardhii during all the sampled months in both seasons (dry and rainy), confirming the city sewage treatment plant as the main source of entry of this species in the Igarapé Grande. It was also confirmed that the distribution of the organisms on the water surface affects the physico-chemical quality of the Igarapé Grande. Statistical analysis enabled the identification of ammonia as the parameter of greatest contribution to the toxicity in the sampled locations. In addition, confirmation was obtained by the chemometric tests PCA, FA, HCA and PLS. The mouse bioassay tests (LD50 - 24h) showed toxicity at doses above 2,500 mg.Kg-1 b.w. and at concentrations of cell extract over 50 mg mL-. The higher mortality occurred in 75% of individuals in the group that received concentrations of 100 mg mL- of the material collected at E3 during the dry season. The results of E2 sampling station showed mortality of 25% of individuals at extract concentration of 50 mg mL-; 25% of individuals at 100 mg mL- and 75% of individuals at concentration of 150 mg mL- from the samples collected during the rainy season.
57

Estrutura da comunidade microbiana (algas e bactérias) em um sistema de lagoas de estabilização em duas escalas temporais: nictemeral e sazonal / Microbial structure (algae and bacteria) from a wastewater stabilization ponds system in two different temporal scale: nictemeral and seasonal

Patrícia Bortoletto de Falco 20 December 2005 (has links)
O estudo da comunidade microbiana que participa do processo de estabilização da matéria orgânica presente nos efluentes sanitários é fundamental para o melhor conhecimento dos tipos de sistemas de tratamento biológico. A avaliação da dinâmica de algas e bactérias presentes no sistema australiano de lagoas de estabilização da cidade de Novo Horizonte (SP) foi o principal objetivo deste trabalho. Para esta avaliação foram determinadas as densidades destes organismos (contagem direta) e a taxa de produção fitoplanctônica (medida pela produção de oxigênio dissolvido) e comparadas às condições abióticas, em escala nictemeral (coletas a cada 6 horas), sazonal (4 épocas do ano), espacial longitudinal (5 estações ao longo do sistema) e vertical (3 profundidades nas lagoas facultativas). Os resultados obtidos indicaram diferenças sazonais na qualidade do efluente final e no desempenho das lagoas. Mesmo com estas diferenças, o efluente final pode ser considerado como potencialmente eutrofizante quanto à concentração de matéria orgânica e de fósforo total. As lagoas facultativas apresentaram condição de anaerobiose na maior parte da coluna de água, o que contribuiu com a não eficiência do sistema / The study of the microbial community (algae and bacteria) that participates of the organic matter stabilization process in the effluent sanitary it is important for the best knowledge of the types of the biological treatment systems. The evaluation of the dynamics of the algae and bacteria in the Australian wastewater stabilization ponds of the Novo Horizonte city (SP) was the main objective of this research. For this evaluation, the densities of these organisms (direct counting) and the primary production rate were determined (measured for the production of oxygen dissolved) and compared to the abiotics conditions, in nictemeral scale (it collects to each 6 hours), seasonal (four periods of the year), longitudinal (5 stations through the system) and vertical spatial (three depths in the facultative ponds). The results indicated seasonal differences in the final effluent quality and in the ponds performance. Although these differences, the final effluent can be considered as potentially eutrophic according to the organic matter and total phosphorus concentrations. The facultative ponds showed an anaerobic condition on the great part of the water column, which contributed with the low efficiency of the system
58

Avaliação da atividade microbiana metanogênica na lagoa de estabilização anaeróbia da estação de tratamento de esgotos sanitários do município de Cajati, Vale do Ribeira do Iguape, Estado de São Paulo / Assessment of anaerobic methanogenic microbial activity at anaerobic stabilization pond of domestic wastewater plant at Cajati city, Vale do Ribeira de Iguape, São Paulo State, Brazil

Lara Steil 31 August 2007 (has links)
O estudo sobre a comunidade microbiana de um sistema de tratamento biológico de águas residuárias é de particular interesse, uma vez que o conhecimento da microbiologia do processo pode levar ao aperfeiçoamento de projetos e ao aumento da eficiência dos sistemas. Este trabalho avaliou a atividade microbiana, particularmente a metanogênica, na lagoa de estabilização anaeróbia da estação de tratamento de esgotos sanitários do município de Cajati - SP. Para isso adotou a taxonomia polifásica na caracterização dos microrganismos e de seus aspectos funcionais, buscando o conhecimento da diversidade dos microrganismos e suas relações nesse tipo de sistema anaeróbio. Objetivou também contribuir para o estabelecimento de um protocolo seguro na realização dos ensaios de atividade metanogênica específica (AME). Os estudos foram realizados com amostras dos sedimento da lagoa coletadas em três períodos diferentes, a saber: outubro/2003, outubro/2004 e dezembro/2004. Durante as amostragens foram determinadas variáveis abióticas como temperatura, condutividade, pH, potencial de óxido-redução e teor de oxigênio dissolvido. Medidas do conteúdo de sólidos totais e voláteis (SV) foram também realizadas. A avaliação da atividade microbiana foi feita por exames microscópicos de contraste de fase e fluorescência, AME, determinação do DNAtotal, FISH - hibridização in-situ com sondas fluorescentes e DGGE - eletroforese em gel com gradiente linear de agentes desnaturantes. Também procedeu-se a contagem de protozoários e análise da presença de algas e cianobactérias. Os resultados revelaram que ocorreu variação nas condições do processo biológico nos períodos amostrados, sendo que em outubro/2004, durante período de fortes chuvas e ventos, a eficiência na redução da DBO foi apenas 18,2%. Nesse período, constatou-se organismos como algas do gênero Chorella sp e cianobactérias do gênero Merismopedia sp. Nas demais coletas a remoção da matéria orgânica medida em DBO foi superior a 80%, com boa atividade anaeróbia. Os resultados mostraram que a relação So/Xo de 0,25 gDQO/g SV foi a mais adequada para determinar o valor de AME, e os ensaios com as amostras de outubro/2003 e dezembro/2004 revelaram valores de AME na faixa de 0,85 a 0,21 mg\'CH IND.4\'/gSV.d. Constatou-se a ocorrência de alterações na estrutura da comunidade microbiana inicial em relação à final do experimento de AME, por meio do DGGE. Verifcou-se também nesses ensaios, que o conteúdo de SV inicial variou entre amostras e substratos, conferindo alta variabilidade ao teste. Os perfís de DGGE das amostras coletadas revelaram variação na estrutura das comunidades microbianas no sedimento, e maior diversidade de bactérias e arquéias quando a lagoa anaeróbia apresentava boa eficiência na redução da DBO. A técnica FISH como adotada não foi eficaz para quantificar e identificar os microrganismos devido ao excesso de hibridizações inespecíficas. Mesmo com suas limitações, a técnica FISH revelou a presença de microrganismos dos Domínios Bacteria e Archaea. Nesse caso, a Família Methanobacteriaceae, a ordem Methanomicrobiales e o gênero Methanosaeta sp. foram confirmados. Nas diferentes coletas, foram identificados protozoários dos gêneros Paramecium sp. e Vorticella sp., e rotíferos dos gêneros Brachionus sp., Trichocerca sp., Synchaeta sp. e Keratella sp. / Microbial diversity studies have remarkable relevance since the knowledge about the microbiology of process can improve plants and system efficiency. This work assessed microbial activity, specially methanogenic, at anaerobic pond for domestic wastewater treatment in the city of Cajati, São Paulo State, Brazil. Poliphasic taxonomy was adopted in onder to contribute to the understanding of microbial community diversity and functionality. As well as to contribute for the establishment of a protocol to the specific methanogenic activity test (SMA). Three periods of sampling were done at the sediment of the anaerobic pond (october 2003, october 2004 and december 2004). Abiotic variables as temperature, conductivity, pH, dissolved oxygen and redox potential were measured at sampling time. TS and VS contents were determined in the samples. Microbial studies were done by observation on optical and fluorescent microscopy, analyse of SMA, totalDNA quantitation, counting of protozoa, analyze of algal and cyanobacteria presence, as well as application of two molecular techniques: Fluorescent in-situ Hybridization (FISH) and Denaturing Gradient Gel Electrophoresis (DGGE). Results showed that general conditions of the anaerobic pond changed among samplings. On October 2004, when the rain and wind were very strong, the organic matter removal efficiency (BOD basis) in the anaerobic pond was low (18.2%) and predominant microorganisms were of aerobic algae, as Chorella sp, and the blue-green algae Merismopedia sp. On the other hand, the removal of organics at other two samplings was more than 80% and the anaerobic microbial activity was verified in the sample. SMA tests showed the food/microorganism rate (F/M) of 0.25 gDQO/g VS was the most suitable to the samples. The results showed SMA values between 0.85 and 0.21 mg\'CH IND.4\'/gVS.d for samples of October 2003 and October 2004. SMA test induced modifications in the structure of the microbial community according to DGGE-profile. In addition, VS content, which was used in the SMA tests as biomass measurement, displayed variable behavior making test results difficult to interpret in some situations. DGGE-profile showed variation in the sediment community structure. Higher bacterial and archaeal diversity was observed when anaerobic pond showed 80%, or more, of DBO removal. FISH technique was not a suitable method to secure quantification and identification of the microorganisms from in excess. In spite of the technique limitations, it was possible to identify microorganisms of Bacteria Domain, Archaea Domain, Methanobacteriaceae Family, Methanomicrobiales Order, and microorganisms belonging to Methanosaeta genus. Paramecium and Vorticella were the protozoans identified in all samplings. Rotifers belonging to genders Brachionus, Trichocerca, Synchaeta and Keratella were also observed.
59

Estudo da ocorrência do gênero Aeromonas em sistemas de tratamento de esgotos por lagoas de estabilização no Município de Lins - SP / The ocurrence of the genus Aeromonas in wastewater treatment systems by stabilization ponds in the City of Lins, SP.

Rocha, Solange Martone 24 September 2004 (has links)
Introdução: Organismos pertencentes ao gênero Aeromonas estão amplamente distribuídos no ambiente aquático sendo atualmente considerados como patógenos emergentes. Estudos demonstraram que, estes podem produzir uma série de fatores de virulência, e ainda um maior número de casos clínicos vêm sendo confirmados e atribuídos às diferentes espécies de Aeromonas. Objetivo: Estudar a ocorrência do gênero Aeromonas em efluentes de um sistema de lagoas de estabilização e discutir o significado da presença destes para a saúde pública. Métodos: A determinação de Aeromonas spp foi realizada pela técnica de tubos múltiplos (NMP/100 mL). Para a verificação da presença e ausência (PA) as colônias foram isoladas em ágar sangue ampicilina, ágar amido ampicilina e ágar MacConkey. As colônias que apresentaram resultados presuntivos para o grupo Aeromonas foram submetidas ao reisolamento em Ágar Amido, e a provas bioquímicas para identificação das espécies. O perfil plasmidial foi realizado de acordo com a metodologia descrita por BIRNBOIN & DOLLY 1979. Resultados: Aeromonas spp foram isoladas em 72,4% e 55,1% das amostras provenientes da entrada e saída da lagoa anaeróbia respectivamente, e em 48,3% da saída da lagoa facultativa variando as contagens entre <3 e 3,0x109 NMP/100mL. Na unidade de desinfecção por cloro entre <3 e 9,0 x 105 NMP/mL Conclusões: Observou-se que embora haja uma tendência de decaimento nas contagens de Aeromonas, não é possível eliminá-las do sistema estudado, mesmo após cloração. Esses organismos podem representar um risco à saúde devido à seleção de cepas resistentes que são lançadas no meio ambiente. / Introduction: Organisms of the genus Aeromonas are widely distributed in the aquatic environment, being now considered emerging organisms. Studies show that these organisms can produce a series of virulence factors, and that a major number of clinic cases have been confirmed and attributed to the different species of Aeromonas. Objective: Study the occurrence of the genus Aeromonas in effluents of a stabilization ponds system and discuss the meaning of the presence of these organisms for public health. Methods: Aeromonas spp determination was carried out by the most probable number technique (NMP/100mL). To verify the presence or absence, the colonies were isolated in ampicilin blood agar, starch agar, and Mc Conkey agar. Colonies showing presumptive results for Aeromonas group were re isolated in starch agar and to biochemical tests to identify the specie. The plasmidial profile was carried out according to the methodology described by BIRNBOIN & DOLLY 1979. Results: Aeromonas spp were isolated in 72,4% and 55.1% of the samples from the afluent and the end of anaerobic lagoons, respectively, in 48.3% of the effluent of the facultative lagoon in counts that varied from <3 and 3.0x109 NMP/100mL. In the disinfection unit counts varied from <3 and 9.0x105 NMP/100mL. Conclusions: It was possible to observe that even though a tendency of decaiment was noted for the counts of Aeromonas, it was not possible to totally eliminate this organisms from the studied system, even after the chlorination. These organisms could pose a health risk due to the selection of resistant strains released in the environment
60

Desempenho de estações de tratamento de esgoto: uma análise de sistemas de lagoas de estabilização de pequeno e médio porte integrada à avaliação da qualidade dos corpos hídricos na UGRHI 12 - Baixo Pardo/Grande / Performance of wastewater treatment plants: an analysis of small and medium wastewater treatment pond systems integrated with evaluation of water bodies quality in UGRHI 12 - Baixo Pardo/Grande

Leonel, Letícia Franco 02 September 2016 (has links)
Apesar dos avanços nos índices de coleta e tratamento de esgotos no Estado de São Paulo, ainda existem incertezas sobre a efetividade dos sistemas de tratamento existentes, uma vez que são escassas as informações sobre o desempenho das ETEs em operação no país. Por meio da aquisição e análise de dados de desempenho do sistema, é possível a avaliação do cumprimento da legislação ambiental e a melhoria das condições operacionais, reduzindo, efetivamente, o impacto do lançamento sobre os recursos hídricos. Nesse sentido, o presente trabalho teve como objetivo avaliar estatisticamente o desempenho de lagoas de estabilização - tecnologia de tratamento mais utilizada no Estado de São Paulo - localizadas na UGRHI 12 - Baixo Pardo/Grande, todas com vazão de projeto inferior a 300 L/s, utilizando dados de automonitoramento fornecidos pelos prestadores de serviço. A avaliação compreendeu um período de 10 anos (2005 a 2014) e abrangeu desde os projetos das lagoas até a caracterização dos dados afluentes e efluentes das ETEs, incluindo também o impacto do lançamento dos esgotos tratados nos corpos receptores e a qualidade dos corpos d\'água em escala de bacia hidrográfica, utilizando os dados da rede de monitoramento da CETESB na UGRHI 12. O desempenho das ETEs foi avaliado quanto aos parâmetros DBO, DQO, CT, E. coli, SS, N-amoniacal e P-total, considerando tanto as faixas típicas apontadas na literatura, como o atendimento aos padrões de lançamento e qualidade. Os dados disponibilizados foram bastante heterogêneos, apresentando, em sua maioria, periodicidades de amostragem variáveis e interrupções no monitoramento, o que impediu, em alguns casos, a realização de uma análise mais consistente. As concentrações afluentes de matéria orgânica foram mais elevadas do que os valores usuais expressos na literatura, sendo a causa mais provável o baixo consumo de água aliado ao tipo de amostragem praticado (amostragem simples). De maneira geral, o desempenho das lagoas, considerando as eficiências médias de remoção de DBO e DQO, ficou dentro do esperado, o que não foi suficiente, contudo, para garantir percentuais elevados de conformidade com a legislação do estado de São Paulo, os quais resultaram abaixo de 80% na maioria das ETEs. Quanto às concentrações nos esgotos tratados, o desempenho ficou aquém do esperado, o que implicou no lançamento de efluentes com concentrações elevadas de matéria orgânica, embora de acordo com os padrões de lançamento pelo critério da eficiência de remoção. A avaliação do corpo receptor mostrou que, mesmo se tratando de vazões relativamente baixas, tais lançamentos foram capazes de impactar os cursos d\'água, notadamente aqueles com baixas razões de diluição. Finalmente, em escala de bacia hidrográfica, verificou-se que, nos corpos d\'água da UGRHI 12, ainda permanecem percentuais elevados de desconformidade para P-total e E. coli, contribuindo para esse cenário tanto as fontes de poluição pontuais como as difusas. / Despite advances in wastewater collection and treatment indicators in São Paulo state, there are still uncertainties about the effectiveness of existing treatment systems, since they is little information on the performance of WTPs operating in the country. Throughout the acquisition and analysis of system performance data, it is possible to evaluate the compliance with environmental legislation and improve operating conditions, effectively reducing the impact of the discharge on water resources. In this sense, the present study aimed to evaluate statistically the performance of stabilization ponds - wastewater treatment technology most widely used in São Paulo state - located in UGRHI 12 - Baixo Pardo/Grande, all of them with design flow rates below 300 L/s, using self-monitoring data given by the service providers. The evaluation comprised a period of 10 years (2005-2014), including from the projects of the ponds to the characterization of WTPs influent and effluent data, also incorporating the impact of treated wastewater release in receiving bodies and the quality of water bodies in watershed scale, using the data from CETESB\'s monitoring network in UGRHI 12. The performance of the WTPs was evaluated for BOD, COD, total coliforms, E. coli, suspended solids, ammonia and total phosphorus, considering the typical ranges mentioned in the literature and compliance with discharge and water quality standards. The provided data were quite heterogeneous, most of them presenting variable sampling periodicities and interruptions in monitoring, sometimes hindering a more consistent analysis. The influent\'s concentrations of organic matter were higher than the usual values expressed in the literature, which was most likely caused by low water consumption combined with the type of sampling practiced (single sampling). In general, the ponds\' performance, considering the average BOD and COD removal efficiencies, was as expected, however, such values weren\'t enough to ensure high percentage of compliance with São Paulo\'s environmental legislation, since the percentages were below 80% in most WTPs. Regarding the concentrations in treated wastewater, the performance was less than expected, which resulted in the discharge of effluents with high concentrations of organic matter, even though they were in compliance with discharge standards by the removal efficiency criterion. The evaluation of the receiving stream showed that, even consisting of relatively low flow rates discharges, such releases were able to impact the water bodies, especially those with low dilution ratio. Finally, in watershed scale, it was found that, in UGRHI 12 water bodies, there are still high percentages of non-conformity for total phosphorus and E. coli, contributing to this scenario both point and non-point sources of pollution.

Page generated in 0.1074 seconds