• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 28
  • 28
  • 18
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da densidade óptica e da resistência à flexão de três pontos em corpos-de-prova fundidos com a liga metálica High Bond (Co-Cr), com secções vertical 90°, diagonal 45° e diagonal 22,5°, soldados pelas técnicas convencional e TIG /

Pereira, Leonardo Viana. January 2012 (has links)
Orientador: Stefan Fiuza de Carvalho Dekon / Banca: Marco Polo Marchese / Banca: Gilberto Aparecido Coclete / Resumo: O sucesso das próteses sobreimplantes está diretamente relacionado ao grau de adaptação dos componentes protéticos aos implantes. Com a finalidade de se obter um assentamento passivo entre a prótese e os implantes, as estruturas metálicas são confeccionadas inicialmente segmentadas e, posteriormente, soldadas clinicamente para minimizar as distorções do processo de fundição. O sistema TIG (Tungsten Inert Gas) é definido como uma soldagem de arco elétrico, estabelecido entre um eletrodo não consumível à base de tungstênio e a peça a ser soldada. O propósito desse estudo foi, através do uso da densidade óptica e de um teste mecânico de resistência à flexão de 3 pontos, analisando a rigidez do material e a tensão de flexão, verificar o comportamento de dois sistemas de soldas odontológicas: convencional e TIG, realizadas em diferentes angulações (90°, 45° e 22,5°) de secções das porções a serem soldadas, comparando-os a um grupo fundido em monobloco (controle), em uma liga de Co-Cr. Os grupos foram comparados entre si quanto à densidade óptica, rigidez, tensão de flexão. A análise dos resultados obtidos possibilitou as seguintes conclusões: 1. Em relação à análise dos dados da densidade óptica mostrou que o grupo controle apresentou-se mais eficientes, estatisticamente significantes, quando comparadas aos grupos do sistema de solda TIG; não houve diferenças estatisticamente significantes entre as diferentes angulações num mesmo sistema de soldagem, porém quando comparados os sistemas de soldagem numa mesma angulação, o grupo de 22,5°-solda convencional teve resultado melhor, estatisticamente significante, que o 22,5°-solda TIG; 2. Em relação à rigidez (modulo de elasticidade), houve diferença estatisticamente significante apenas quando se comparou os corpos com angulação de 90° com diferentes soldas, tendo resultados maiores com ... / Abstract: The success of the prosthesis over implant is directly related to the adaptation degree of the prosthesis components to implants. Aiming to obtain a passive fit between the prosthesis and the implant, initially the metal structures are segmented and later are clinically welded to minimize the distortions of the casting process. The TIG system (Tungsten Inert Gas) is defined as a welding of an electric arc, established between a non consumable electrode based on tungsten and the part to be welded. The purpose of this study was to use the optical density and a mechanical test of 3 points flexion endurance, to analyze the stiffness of the material and the bending stress and to verify the behavior of two systems of dental welders: conventional and TIG performed at different angles (90º, 45º e 22, 5º) of the sections of the portions to be welded, and compare them to a group fused on monobloc (control) in an alloy of Co-Cr. The groups were compared on optical density, stiffness and bending stress. Analysis of the results made possible the following conclusions: 1. The analysis of the data showed that the optical density of the control group was more efficient, statistically significant, when compared to the groups with TIG welding system; there were no statistical differences between the different angles on the same welding system, although when comparing the welding systems in the same angle, the group of 22,5º- conventional welding had better result than the 22,5º - TIG welding, this difference was statistically significant; 2. There was statistical significant difference regarding the stiffness (modulus of elasticity) only when it was compared the bodies with the 90º angle with different welds, the higher results were with the conventional welding; 3. The results of the... / Mestre
12

Resistência à fratura de infraestruturas de próteses totais implantossuportadas em função de diferentes desenhos de cantilever e espessura do conector distal: estudo in vitro / Fracture resistance of infrastructure implant-supported dentures due to different design of cantilever and the thickness of the distal connector : in vitro study

Oliveira, Brunamélia de [UNESP] 25 July 2016 (has links)
Submitted by BRUNAMÉLIA DE OLIVEIRA null (brunamoliveira@hotmail.com) on 2016-09-16T11:59:43Z No. of bitstreams: 1 TESE DOUTORADO_23-agost-2016- wirley.doc: 39192064 bytes, checksum: 979dfe3777702d653e46da90ffda2ead (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Por favor, corrija o formato do arquivo e realize uma nova submissão. Agradecemos a compreensão. on 2016-09-21T13:09:53Z (GMT) / Submitted by BRUNAMÉLIA DE OLIVEIRA null (brunamoliveira@hotmail.com) on 2016-09-21T13:51:25Z No. of bitstreams: 1 TESE DOUTORADO Brunamélia de Oliveira-PDF.pdf: 1338467 bytes, checksum: 256bd9b6a59b22460bfa4b2d78f3caa4 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-09-21T20:35:33Z (GMT) No. of bitstreams: 1 oliveira_b_dr_araca.pdf: 1338467 bytes, checksum: 256bd9b6a59b22460bfa4b2d78f3caa4 (MD5) / Made available in DSpace on 2016-09-21T20:35:33Z (GMT). No. of bitstreams: 1 oliveira_b_dr_araca.pdf: 1338467 bytes, checksum: 256bd9b6a59b22460bfa4b2d78f3caa4 (MD5) Previous issue date: 2016-07-25 / O objetivo do presente trabalho foi avaliar, por meio de teste de compressão, a resistência à fratura de infraestruturas metálicas de próteses totais implantossuportadas do tipo protocolo de Branemark em função de diferentes designs (comprimentos e altura) do cantilever, bem como espessura do conector distal. Foram confeccionadas 39 infraestruturas (barras) em liga de CoCr agrupadas de acordo com o comprimento do cantilever (cc) (12mm, 19mm e 26mm), altura do cantilever (hc) (3,2 mm, 4mm) e espessura do conector distal (ec) (0,4mm, 1,5mm e 2mm). Os grupo foram divididos em Controle (cc 12mm; hc 4mm; ec 1,5),Grupo 1 (cc 12mm; hc 4mm; ec 0,4mm), Grupo 2(cc 12mm; hc 3,2mm; ec 0,4mm), Grupo 3 (cc 12mm; hc 3,2mm; ec 1,5mm), Grupo 4 (cc 19mm; hc 4mm; ec 1,5mm), Grupo 5 (cc 19mm; hc 4mm; ec 0,4mm), Grupo 6 (cc 19mm; hc 3,2mm; ec 1,5mm), Grupo 7 (cc 19mm; hc 3,2mm; ec 0,4mm), Grupo 8 (cc 26mm; hc 4mm; ec 1,5mm), Grupo 9 (cc 26mm; hc 4mm; ec 0,4mm), Grupo 10 (cc 26mm; hc 3,2mm; ec 1,5mm) e Grupo 11 (cc 26mm; hc 3,2mm; ec 0,4mm). Todos os espécimes foram submetidos a ensaio de compressão em uma maquina de ensaio universal com célula de carga de 5000N e velocidade constante de 0,5mm/min. Os dados obtidos foram submetidos a analise estatística ANOVA a três critérios, seguido pelo teste de Tukey, com nível se significância de 5% (p<0,05). Foi observada uma diferença significante na diminuição de resistência a compressão com o aumento do comprimento do cantilever, um aumento significante de resistência nos grupos com altura de cantileveres maiores. Foi concluído que quanto menor o comprimento e maior a altura do cantielver, maior será a resistência. Já a espessura do conector influenciou a resistência, porém sem uniformidade. / The aim of this study was to evaluate, through compression test, the fracture strength of metal infrastructure dentures implant of the Branemark protocol type for different designs (length and height) of the cantilever and thickness of the connector distal. 39 were prepared infrastructure (bar) pooled CoCr alloy according to the length of the cantilever (cc) (12mm, 19mm and 26mm), the cantilever height (hc) (3.2mm, 4mm) thick and the distal connector ( c) (0.4mm, 1.5mm and 2mm). The group were divided into control (cc 12mm; hc 4mm and c 1.5), Group 1 (cc 12mm; hc 4mm, 0.4mm c), Group 2 (cc 12 mm; hc 3.2mm, 0.4mm and c) Group 3 (cc 12 mm; hc 3.2mm, 1.5mm c), Group 4 (cc 19mm; hc 4mm, 1.5mm c), Group 5 (cc 19mm; hc 4mm, 0.4mm c), Group 6 (cc 19mm; hc 3.2mm, 1.5mm c), Group 7 (cc 19mm; hc 3.2mm, 0.4mm c), Group 8 (cc 26mm; hc 4mm, 1.5mm c), Group 9 ( cc 26mm; hc 4mm, 0.4mm c) Group 10 (cc 26mm; hc 3.2mm, 1.5mm c) and Group 11 (cc 26mm; hc 3.2mm, 0.4mm and c). All specimens were subjected to compression test in a universal testing machine with 5000N load cell and constant speed of 0.5 mm / min. Data were analyzed by ANOVA statistical analysis three criteria, followed by Tukey test, with significance level was 5% (p <0.05). a significant difference in the decrease of resistance to compression with increasing length of the cantilever, a significant increase in resistance groups with height greater cantilevers was observed. It was concluded smaller length and greater height of cantielver, the greater the resistance. Already the connector thickness influenced the resistance, but without uniformity.
13

Resistência à fratura de infraestruturas de próteses totais implantossuportadas em função de diferentes desenhos de cantilever e espessura do conector distal : estudo in vitro /

Oliveira, Brunamélia de. January 2016 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Humberto Gennari Filho / Banca: Juliana Aparecida Delben / Banca: Erica Alves Gomes / Resumo: O o bjetivo do presente trabalho foi avaliar, por meio de teste de compressão, a resistência à fratura de infraestruturas metálicas de próteses totais implantossuportadas do tipo protocolo de Branemark em função de diferentes designs ( comprimentos e altura) do cantilever, b e m como espessura do conector distal . Foram confeccionadas 39 infraestruturas ( barras ) em liga de CoCr agrupadas de acordo com o comprimento d o cantilever (cc) (12mm, 19mm e 26mm), altura do cantilever (hc) (3, 2 mm, 4mm) e espessura do conector distal (ec) (0,4mm, 1,5mm e 2mm). Os grupo foram divididos em Controle (cc 12mm; hc 4mm; ec 1,5),Grupo 1 (cc 12mm ; hc 4mm; ec 0,4mm), Grupo 2 (cc 12mm; hc 3,2mm; ec 0,4mm), Grupo 3 (cc 12mm; hc 3,2mm; ec 1,5mm), Grupo 4 (cc 19mm; hc 4mm; ec 1,5mm), Grupo 5 (cc 19mm; hc 4mm; ec 0,4mm), Grupo 6 (cc 19mm; hc 3,2mm; ec 1,5mm), Grupo 7 (cc 19mm; hc 3,2mm; ec 0,4mm), Grupo 8 (cc 26m m; hc 4mm; ec 1,5mm), Grupo 9 (cc 26mm; hc 4mm; ec 0,4mm), Grupo 1 0 (cc 26mm; hc 3,2mm; ec 1,5mm) e Grupo 1 1 (cc 26mm; hc 3,2mm; ec 0,4mm). Tod o s o s espécimes foram submetid o s a ensaio de compressão em uma maquina de ensaio universal com célula de carga de 5000N e velocidade constante de 0,5mm/min . Os dados obtidos foram submetidos a analise estatística ANOVA a três critérios, seguido pelo teste de Tukey, com nível se significância de 5% (p< 0,0 5 ). Foi observada uma diferença significante na diminuição de re sistência a compressão com o aumento do comprimento do cantilever, um aumento significante de resistência nos grupos com altura de cantileveres maiores . Foi concluído que quanto menor o comprimento e maior a altura do cantielver, maior será a resistência. Já a espessura do conector influenciou a resistência, porém sem uniformidade. / Abstract: The aim of this study was to evaluate, thr ough compression test, the fracture strength of metal infrastructure dentures implant of the Branemark protocol type for different designs (length and height) of the cantilever and thickness of the connector distal. 39 were prepared infrastructure (bar) po oled CoCr alloy according to the length of the cantilever (cc) (12mm, 19mm and 26mm), the cantilever height (hc) (3.2mm, 4mm) thick and the distal connector ( c) (0.4mm, 1.5mm and 2mm). The group were divided into control (cc 12mm; hc 4mm and c 1.5), Group 1 (cc 12mm; hc 4mm, 0.4mm c), Group 2 (cc 12 mm; hc 3.2mm, 0.4mm and c) Group 3 (cc 12 mm; hc 3.2mm, 1.5mm c), Group 4 (cc 19mm; hc 4mm, 1.5mm c), Group 5 (cc 19mm; hc 4mm, 0.4mm c), Group 6 (cc 19mm; hc 3.2mm, 1.5mm c), Group 7 (cc 19mm; hc 3.2mm, 0.4mm c), Group 8 (cc 26mm; hc 4mm, 1.5mm c), Group 9 ( cc 26mm; hc 4mm, 0.4mm c) Group 10 (cc 26mm; hc 3.2mm, 1.5mm c) and Group 11 (cc 26mm; hc 3.2mm, 0.4mm and c). All specimens were subjected to compression test in a universal testing machine with 5000N load cell and constant speed of 0.5 mm / min. Data were analyzed by ANOVA statistical analysis three criteria, followed by Tukey test, with significance level was 5% (p <0.05). a significant difference in the decrease of resistance to compression with increasi ng length of the cantilever, a significant increase in resistance groups with height greater cantilevers was observed. It was concluded smaller length and greater height of cantielver, the greater the resistance. Already the connector thickness influenced the resistance, but without uniformity. / Doutor
14

"Estudo comparativo de dois métodos utilizados na fundição de titânio cp" / Comparative study of two cp Ti casting methods.

Renata Cristina Silveira Rodrigues 29 April 2005 (has links)
Ao longo da última década, vários trabalhos têm destacado as vantagens do titânio e suas ligas e estudado a possibilidade de utilização para a confecção de estruturas metálicas de prótese parcial removível. Apesar das vantagens, o processo de fundição ainda apresenta problemas, limitando o uso do titânio. O objetivo deste estudo foi avaliar a influência de dois métodos de fundição, sobre microestrutura, microdureza, porosidade e força de retenção de grampos de PPR, fundidos em Co-Cr (controle) e titânio comercialmente puro (Ti cp). Foram utilizados os seguintes métodos: 1- arco voltaico (plasma) sob vácuo e pressão de argônio, com injeção do metal fundido por vácuo-pressão, e 2- indução sob vácuo e atmosfera de argônio, com injeção do metal fundido por centrifugação. Para análise da força de retenção foram confeccionadas estruturas metálicas com grampos circunferenciais sob retenção de 0,25; 0,50 e 0,75 mm, submetidas a ciclos de inserção/remoção simulando o uso por um período de 5 anos. Previamente ao ensaio de simulação, os corpos-de-prova foram radiografados em unidade laboratorial de raios X. Para o ensaio de microdureza Vickers e microestrutura foram confeccionados discos, com 5 mm de diâmetro e 2 mm de espessura, polidos metalograficamente. Os resultados mostraram que os métodos de fundição interferem nas características dos materiais estudados. As peças em titânio cp fundidas por plasma/vácuo-pressão apresentaram maior número de porosidades (50%) do que as fundidas por indução/centrifugação (16,66%). Para as peças fundidas em liga de Co-Cr, segundo a metodologia empregada, não foi possível observar a ocorrência de porosidades. As peças fundidas por plasma/vácuo-pressão apresentaram maior flexibilidade e as fundidas por indução/centrifugação apresentaram maior rigidez. Conseqüentemente, as forças de retenção foram, em geral, maiores para os corpos-de-prova obtidos por indução/centrifugação do que para aqueles obtidos por plasma/vácuo-pressão, com exceção da condição experimental de retenção 0,75 mm. Os corpos-de-prova fundidos por indução/centrifugação apresentaram, tanto para o Ti cp quanto para a liga de Co-Cr, maiores valores de microdureza Vickers do que os fundidos por plasma/vácuo-pressão. O Ti cp fundido pelo método de indução/centrifugação resultou em microestrutura de aspecto Widmanstätten, enquanto quando fundido pelo método de plasma/vácuo-pressão tem aspecto metalográfico tipo feather-like. Para a liga de Co-Cr, ambos os métodos resultaram em microestrutura dendrítica, mais fina para o método de plasma/vácuo-pressão. O Ti cp e a liga de Co-Cr, parecem ser afetados pela velocidade de resfriamento associada ao equipamento utilizado. Na análise química não foram detectadas alterações de composição dos materiais que indicassem contaminação resultante dos métodos de fundição utilizados. Assim, embora ainda apresentem problemas técnicos a serem resolvidos, ambos os métodos de fundição, indução/centrifugação e plasma/vácuo-pressão, permitem a obtenção de resultados satisfatórios na produção de estruturas metálicas de PPR em Ti cp. / Along the last decade, several jobs have been highlighting the advantages of titanium and titanium alloys and studied the possible utilization for removable partial dentures (RPD) metal frameworks confection. Although advantages, the cast process still presents problems, limiting the titanium use. The objective of this study was to evaluate the influence of two casting methods, on microstructure, microhardness, porosity and retention force of RPD clasps, casted in Co-Cr alloy (control) and commercially pure titanium (cp Ti). The cast methods used were: 1- voltaic arc (plasma) under vacuum and argon pressure, with molten metal injection by vacuum-pressure, and 2- induction under vacuum and argon atmosphere, with molten metal injection by centrifugation. For retention force analysis were made metal frameworks with circumferential clasps under retention of 0.25; 0.50 and 0.75 mm, submitted to insertion/removal cycles, simulating a 5 years use of a metal framework. Previously to the simulation test, the samples were radiographed in a laboratorial unit to verify the porosities occurrence. For Vickers microhardness test and microstructure analysis, disks with 5mm diameter and 2 mm thickness were made. The results showed that the casting methods interfere in the characteristics of studied materials. The cp Ti pieces casted by plasma/vacuum-pressure presents larger porosities number (50%) than that casted by induction/centrifugation (16.66%). For the pieces casted in Co-Cr alloy, according to the used methodology, wasn't possible to observe the occurrence of porosities. The pieces casted by plasma/vacuum-pressure presents larger flexibility and that casted by induction/centrifugation present larger rigidity. Consequently, the retention forces were, in general, larger for the samples obtained by induction/centrifugation than for those obtained by plasma/vacuum-pressure, except for the experimental condition with 0.75 mm retention. The samples casted by induction/centrifugation present, as for cp Ti as for Co-Cr alloy, larger Vickers microhardness values Vickers than that casted by plasma/vacuum-pressure. The cp Ti casted by induction/centrifugation method resulted in Widmanstätten microstructural aspect, while when casted by plasma/vacuum-pressure method has feather-like aspect. For Co-Cr alloy, both methods resulted in dendritic microstructure, finer for plasma/vacuum-pressure method. The cp Ti and Co-Cr alloy seem to be affected by the cooling rate associate to the used equipment. In the chemical analysis weren't detected materials composition alterations that indicate resultant contamination for the used casting methods. Thus, however still present technical problems to be solved, both casting methods, induction/centrifugation and plasma/vacuum-pressure, allow the obtainment of satisfactory results in the RPD metal frameworks production in cp Ti.
15

Comparação da razão carga-deflexão do fio flexy-multi® com fios de aço, beta-titânio e níquel-titânio de diversas marcas comerciais / Comparison of the load-deflection rate of niti/beta-titanium with stainless-steel, beta-titanium and nickel-titanium wires from different manufacturers

Póvoa, Vinícius Marcelo Aires 21 December 2011 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2016-08-29T18:10:51Z No. of bitstreams: 2 Dissertação - Vinícius Marcelo Aires Póvoa - 2011.pdf: 2752370 bytes, checksum: 9fbffc261c22bdc57a1b99d2aed34d3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2016-08-29T18:12:36Z (GMT) No. of bitstreams: 2 Dissertação - Vinícius Marcelo Aires Póvoa - 2011.pdf: 2752370 bytes, checksum: 9fbffc261c22bdc57a1b99d2aed34d3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-29T18:12:36Z (GMT). No. of bitstreams: 2 Dissertação - Vinícius Marcelo Aires Póvoa - 2011.pdf: 2752370 bytes, checksum: 9fbffc261c22bdc57a1b99d2aed34d3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2011-12-21 / Flexy-Multi™, a newly introduced finishing wire with the outermost portion of its crosssection composed by nickel-titanium and its core by beta-titanium, was evaluated according to its flexural behavior in bending tests. The aim of this study was to compare the loaddeflection rate of Flexy-Multi™ to stainless-steel, beta titanium and nickel-titanium archwires in three-point bending test. The samples examined included 0.017”x 0.025”-inch stainlesssteel, beta-titanium, nickel-titanium and Flexy-Multi™ wires. Each combination, alloy and manufacturer, was tested 6 times and an average was obtained for comparison. All specimens were tested in a universal testing machine (EMIC DL10.000/700) in a 3-point bending test at a speed of 1mm per minute and deflected for 1.5 mm. Loading and unloading forces were recorded at each 0.5mm of deflection and load-deflection curves were determined. Three self-ligating brackets of lower incisors (In-Ovation – GAC Orthodontics, Roth prescription, slot .022”x.028”) were used as supports to the wires. On loading, there was no difference between Flexy-Multi™ and all nickel-titanium wires tested. On the other hand, Flexy-Multi™ showed lower load-deflection rates than all stainless-steel and betatitanium wires both on loading and unloading (p>0.05). On unloading, Flexy-Multi™ showed lower load-deflection rate than all nickel-titanium wires just to 0.5mm of deflection (p<0.05). Flexy-multi™ presented a lower load-deflection rate than all wires tested, except when compared to nickel-titanium where this difference came up just at the level of 0.5mm of unloading, since this wire lost force by the end of the test. / O Flexy-Multi®, fio recentemente introduzido ao mercado brasileiro, composto por uma camada externa de níquel-titânio e um núcleo central de beta-titânio, foi avaliado de acordo com o seu comportamento mecânico em testes de flexão. O objetivo do presente trabalho foi comparar a proporção carga/deflexão do Flexy-Multi® com fios de aço, beta-titânio e níquel-titânio em testes de flexão em três bráquetes. As amostras avaliadas constituíam-se de fios 0,017” x 0,025” de aço, beta-titânio, níquel-titânio e o Flexy-Multi®. Cada combinação, liga e fabricante, foi testada 6 vezes e médias foram obtidas para comparação. Todos os espécimes foram submetidos a ensaios de flexão em três pontos em máquina universal de ensaio EMIC DL10.000/700, utilizando bráquetes autoligados de incisivos inferiores (In-Ovation, slot 0,022” x 0,028” e prescrição Roth) como suportes. A velocidade dos ensaios foi de 1mm/min com deflexão máxima de 1,5mm. Forças de ativação e desativação foram registradas a cada 0,5mm e curvas carga x deflexão estabelecidas. Na ativação, não houve diferença entre o Flexy-Multi® e os demais fios de níquel-titânio testados. Por outro lado, o Flexy-Multi® mostrou menor proporção carga/deflexão que todos os fios de aço e beta-titânio, tanto na ativação quanto na desativação (p>0,05). Na desativação, o Flexy-Multi® mostrou menor proporção carga-deflexão que todos os fios de níquel-titânio testados apenas para 0,5mm de deflexão (p<0,05). O Flexy-Multi® apresentou menor proporção carga-deflexão que todos fios testados, exceto quando comparado aos fios de níquel-titânio, já que neste caso esta diferença se evidenciou apenas para 0,5mm de deflexão na desativação, evidenciando uma perda de força deste fio ao final do teste.
16

Resistência de união entre o titânio fundido e cimentos resinosos, comparada com a de uma liga de níquel-cromo. / Tensile bond strength of titanium and a nickel-chromium alloy cemented with resin cements.

Rodrigo de Oliveira França 29 August 2000 (has links)
O objetivo da pesquisa foi avaliar a resistência de união entre o titânio fundido e cimentos resinosos, comparada com a de uma liga de níquel-cromo. Os fatores estudados foram: cimentos (Enforce, Cimento de resina 3M, Cement-it); conjugação liga/ revestimento ( titânio obtido com revestimento com a case e sem a case e liga de níquel-cromo, com fosfatado); tratamento superficial ( jateamento com óxido de alumínio e sistema Siloc); desgaste (cimentação antes do desgaste e depois). Para os espécimes foram obtidos discos por fundição, que foram jateados com óxido de alumínio. A metade foi cimentada depois desse tratamento e outra após a aplicação do Siloc. A armazenagem foi por 5 dias fazendo-se termociclagem (1.000 ciclos). Após o rompimento dos espécimes, por ensaio de tração, as superfícies cimentadas foram desgastadas com lixa n o 200 e novamente cimentadas. As conclusões foram: houve grande diferença entre cimentos; o titânio e o níquel-cromo nas devidas condições apresentaram retentividades semelhantes; o Siloc aumentou muito a retenção; o desgaste só influiu um pouco no titânio a case. / The Purpose of the research was to evaluate tensile bond strength of cemented titanium and nickel-chromium alloy cast discs. Factors studied were: Cements (Enforce, Resin cement 3M, Cement-it); Combination alloy/investment ( titanium obtained with a case and without a case investments, and nickel-chromium alloys); surface treatment (sandblasting with Al2O3 and Siloc application): surface abrading (test before and after).Cast discs with fixing stem were sandblasted and half of them were luted in this stage and the other one were luted after Siloc treatment. Specimens were stored for 5 days and thermalcycled (1,000 cycles). After tensile strength test surfaces were abraded and discs were luted again. The conclusions were: cements presented different bond strength; titanium and nickel-chromium alloy, under given condition, presented similar strength; Siloc system presented at least double strength; abrading of a case, titanium enhance only a little bond strength.
17

Efeito de soluções higienizadoras diárias em ligas de cobalto-cromo e resina acrílica termopolimerizável para prótese parcial removível. / Effect of denture cleansers on the properties of removable partial denture: in vitro study.

Daniela Nair Borges Felipucci 09 October 2009 (has links)
A higienização das próteses removíveis é fundamental para a longevidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de higienizadores de imersão nas superfícies da liga metálica e resina acrílica termopolimerizável de Prótese Parcial Removível (PPR), simulando 180 dias. Discos (12 mm x 3 mm) foram confeccionados com ligas metálicas de cobalto-cromo para PPR: Vera PDI® (VP) e DeguDent® (DD). Cada disco metálico foi incluído em mufla previamente preparada por matrizes de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os espécimes (n= 5) foram imersos nas seguintes soluções: água destilada (grupo controle - AD), hipoclorito de sódio 0,05% (HS), Cepacol® (cloreto de cetilpiridínio 0,005% - CE), Periogard® (digluconato de clorexidina 0,12% - PE), Corega Tabs® (peróxido alcalino e enzima - CT), Polident® (peróxido alcalino e enzima - PO) e Medical Interporous Dentures® (ácido cítrico - MI). Foram realizadas análise da estabilidade de cor por meio de espectrocolorímetro, análise visual da presença de manchas no metal, análise da perda de massa em balança de alta precisão e análise da rugosidade por meio de rugosímetro. Como estudo complementar, foram realizadas análises quantitativas da liberação de íons (cobalto e cromo) em cada solução com espectrômetro de massas e análises ópticas e qualitativas com microscópio eletrônico de varredura (MEV) e espectrometria de energia dispersiva de Raios-X (EDS). Os resultados de rugosidade, alteração de cor e massa apresentaram distribuição normal e homogênea, tendo sido submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à rugosidade (Ra&micro;m), não houve diferença estatisticamente significante entre as soluções e ligas tanto para o metal quanto para a resina. Com relação à alteração de cor da resina acrílica termopolimerizável (&Delta;E), houve diferença estatisticamente significante entre as ligas, soluções e na interação liga x solução. As soluções AD, CE e PE propiciaram menores valores que as demais. A resina associada à DD apresentou maior alteração de cor do que quando associada à VP (1,06 ± 0,51 e 0,51 ± 0,28, respectivamente). Com relação à presença de manchas no metal, o HS propiciou manchamento em 100% dos espécimes. O grupo MI/DD propiciou em 60% e o MI/VP em 40% dos espécimes. Quando avaliada a alteração de massa (g), as soluções CT e MI propiciaram maiores valores. Entre as ligas, a VP apresentou maior perda de massa. Com relação à liberação de íons cobalto e cromo, a solução de HS e a MI propiciaram maior liberação e quando comparadas as ligas, VP apresentou maior liberação de íons. Com o MEV pôde-se verificar que houve corrosão generalizada com o HS e por pites com a MI. Concluiu-se que as soluções CE, PE e PO não apresentaram efeitos deletérios podendo ser auxiliares à escovação para higienização de PPR. / The hygiene care of the removable dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on the surfaces of the alloys and heat-polymerized acrylic resin for removable partial denture (RPD), simulating a period of 180 days. Circular specimens (12 mm x 3 mm) had been fabricated with cobalt-chromium alloys: Vera PDI&trade; (VP) and DeguDent&trade; (DD). The cast specimens were centered in the moulds previously prepared by matrices of teflon (38 mm x 18 mm x 4 mm) and the acrylic resin was inserted. The specimens (n= 5) had been immersed in the following solutions: distilled water (control - DW), sodium hypochlorite 0.05% (SH), Cepacol&trade; (cetilpiridinium chloride 0.005% - CE), Periogard&trade; (chlorexidine gluconate 0.12% - PE), Corega Tabs&trade; (alkaline peroxide and enzyme - CT), Polident&trade; (alkaline peroxide and enzyme - PO) and Medical Interporous Dentures&trade; (citric acid - MI). The color stability was analyzed using a colorimeter, and the presence of tarnishes on the metal was performed by a visual analysis. The weight loss was measured with a precision balance and the surface roughness was analyzed with a surf-test analyzer. As complementary analyzes a quantitative study of ions release (cobalt and chromium) using inductively mass spectrometry and optical and qualitative analyses with scanning electron microscopy (SEM) associated to dispersive energy spectrometry were performed. The results of roughness, color stability and weight loss presented normal and homogeneous distribution and were submitted to ANOVA (p &le; 0.05) and Tukey test. There was no significant difference among the solutions and between the alloys for both metal and resin roughness (Ra &micro;m). The acrylic resin color stability (&Delta;E) was analyzed and showed significant difference among the solutions, alloys and interaction. AD, CE and PE solutions presented the lowest values of color changes. The resin associated to DD presented higher color change than when associated with the VP (1.06 ± 0.51 and 0.51 ± 0.28, respectively). The HS caused tarnishes on 100% of specimens. The MI/DD group provided 60% and the MI/VP in 40% of specimens. When was analyzed the mass loss (g), the solutions CT and MI had the higher values. Between the alloys VP presented higher weight loss. HS and MI presented greater ionic release and between the alloys, VP presented greater release. With the SEM it was possible observe the presence of widespread corrosion in the HS group and pites corrosion in the MI group. It was concluded that CE, PE, CT and PO solutions had no deleterious effects on the compounds of RPD and may be indicate as auxiliaries to brushing in the RPD hygiene care.
18

Efeito da ciclagem mecânica e da técnica de fundição sobre o desajuste marginal, tensão e torque de afrouxamento de infraestruturas de próteses múltiplas implantossuportadas = Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses / Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses

Bhering, Cláudia Lopes Brilhante, 1989- 21 June 2013 (has links)
Orientadores: Marcelo Ferraz Mesquita, Jessica Mie Ferreira Koyama Takahashi / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T08:00:41Z (GMT). No. of bitstreams: 1 Bhering_ClaudiaLopesBrilhante_M.pdf: 2599454 bytes, checksum: bd13164e8616791d20fc97e7001d9fc7 (MD5) Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência do processo de fundição e da ciclagem mecânica sobre o desajuste marginal, tensão e torque de afrouxamento de próteses múltiplas implantossuportadas. Infraestruturas de prótese parcial fixa (PPF) suportada por dois implantes e prótese total fixa (PTF) suportada por cinco implantes foram enceradas usando cilindros de mini pilar totalmente calcináveis ou sobrefundidos (n=10). A partir das infraestruturas enceradas, os modelos de trabalho foram confeccionados utilizando análogos de implante (Hexágono Externo - 4.1mm) parafusados a mini pilares e um índex de gesso foi confeccionado utilizando análogos modificados de mini pilar. Quatro grupos foram obtidos de acordo com o tipo de prótese (PPF ou PTF) e cilindro protético (calcinável ou sobrefundido) avaliado. As infraestruturas foram fundidas em liga de CoCr e os parafusos apertados com 20Ncm (mini pilar) e 10Ncm (protético) utilizando torquímetro digital. Após 24 horas, o torque de afrouxamento e o desajuste inicial foram avaliados. O desajuste foi aferido por meio do teste do parafuso único. A análise de tensão foi realizada por meio de strain gauges colados na superfície dos análogos modificados, formando ¼ de ponte de Wheatstone. Os parafusos foram reapertados e as amostras submetidas a 106 de ciclos mecânicos (2Hz/280N). As mensurações finais foram realizadas e os resultados submetidos à Anova - 2 fatores/Teste de Tukey HSD e correlação de Pearson (?=0,05). Não houve diferença no desajuste para todos os intervalos de tempo e grupos avaliados no índex de gesso (p>0,05). As infraestruturas sobrefundidas apresentaram maior tensão que as obtidas com cilindros calcináveis (PPF: Inicial p=0,0047; Final p=0,0004; PTF: Inicial p=0,0476; Final p=0,0115). Não houve influência da ciclagem mecânica na tensão (p>0,05). No modelo de trabalho, as PPFs confeccionadas com cilindros calcináveis apresentaram maior desajuste que as sobrefundidas (Inicial: p=0,0005; Final: p=0,0007). As PTFs apresentaram desajuste similar (p>0,05). A ciclagem mecânica não influenciou o desajuste em ambos os modelos avaliados (p>0,05). Os parafusos de mini pilar das PTFs sobrefundidas apresentaram menor torque de afrouxamento que o grupo calcinável após a ciclagem mecânica (p=0,0024). Os parafusos protéticos dos grupos calcináveis apresentaram menor torque de afrouxamento que os sobrefundidos no tempo final (PPF: p=0,0013; PTF: p=0,0064). O torque de afrouxamento dos parafusos protéticos das PPFs calcináveis diminuiu após a ciclagem mecânica (p=0,0044). Correlação negativa foi observada entre o desajuste e o torque de afrouxamento dos parafusos protéticos (PPF: r=-0,49523 p=0,0012; PTF: r=-0,31423 p=0,0483). Não houve correlação entre o desajuste e a tensão (PPF: r=0,24 p>0,05; PTF: r=0,21 p>0,05). Conclui-se que o benefício do cilindro utilizado em relação à adaptação depende do tipo de prótese e componente sobre o qual o desajuste é avaliado. Próteses confeccionadas com cilindros sobrefundidos geram maior tensão e apresentam maior estabilidade dos parafusos protéticos. A ciclagem mecânica não influencia o desajuste e a tensão de próteses múltiplas, mas reduz o torque de afrouxamento em infraestruturas com maior desadaptação. Não existe correlação entre desajuste vertical decorrente da fundição e a tensão. Contudo, há correlação entre o desajuste marginal e o torque de afrouxamento dos parafusos protéticos mediante a ação de forças dinâmicas / Abstract: This study aimed to evaluate the influence of casting and cyclic loading on marginal misfit, strain and loosening torque of multiple implant-supported prostheses. Fixed partial dentures (FPD) frameworks supported by two implants and fixed full-arch dentures (FAD) frameworks supported by five implants were waxed using overcasted or calcinable mini abutment cylinders (n=10). The models were obtained with external hexagon implant analogs and mini abutments fixed to waxed frameworks. A plaster index was obtained using mini abutment modified analogs for strain gauge analysis. Four groups were obtained according to prosthesis (FPD or FAD) and cylinder (calcinable or overcasted) type. The frameworks were casted in CoCr alloy. The abutment and prosthetic screws were tightened with 20Ncm and 10Ncm, respectively, using digital torque meter. After 24 hours, initial loosening torque and marginal misfit were evaluated. The misfit readings were performed following the single screw test protocol. The prosthetic screws were tightened with 10Ncm and strain analysis performed by strain gauges bonded at the mini abutment analogs surface forming a ¼ of Wheatstone bridge. The screws were retightened and the samples submitted to 106 mechanical cycles (2Hz/280N). The final measurements were performed and the results submitted to 2 way - Anova/Tukey's HSD Test and Pearson Correlation Test (?=0.05). No difference was found in marginal misfit on all time intervals and groups on the plaster index (p>0.05). The frameworks manufactured with overcasted cylinders presented higher strain than calcinables ones, regardless of prosthesis type and time evaluated (FPD: Initial p=0.0047; Final p=0.0004; FAD: Initial p=0.0476; Final p=0.0115). No difference was observed in strain before and after cyclic loading (p>0.05). Considering the resin model, the calcinable FPD groups presented higher marginal misfit than overcasted ones (Initial: p=0.0005; Final: p=0.0007). Similar marginal misfit was noted among FAD groups (p>0.05). The cyclic loading did not affect the marginal misfit (p>0.05) in both evaluated models. The overcasted FADs abutment screws showed lower loosening torque than calcinable ones after cyclic loading (p=0.0024). The prosthetic screws of calcinable frameworks presented lower loosening torque than the overcasted at final measurement (FPD: p=0.0013; FAD: p=0.0064). After cyclic loading, the prosthetic screw loosening torque of calcinable FPDs decreased (p=0.0044). Negative correlation was observed between marginal misfit and loosening torque of prosthetic screws (FPD: r=-0.49523 p=0.0012; FAD: r=-0.31423 p=0.0483). No correlation was observed between misfit and strain (FPD: r=0.24 p>0.05; FAD: r=0.21 p>0.05). It is concluded for marginal fit, the benefit of the cylinder type depends on prosthesis design and component evaluated. Overcasted components generate higher strain and screw stability than totally calcinable ones. The cyclic loading did not influence misfit and strain of multiple-unit prostheses, but decreased the screw loosening torque in poorly fitted frameworks. There was no correlation between marginal misfit resulted from casting and strain induced on the system. There was correlation between marginal misfit and prosthetic screw loosening torque when submitted to cyclic loading / Mestrado / Protese Dental / Mestra em Clínica Odontológica
19

Avaliação comparativa de propriedades geradas pelos processos de soldagem TIG e brasagem em uma liga odontológica à base de Ni-Cr / Comparative assessment of properties generated by the process of TIG welding and brazing in a Ni-Cr dental alloy

Carlos Antonio Freire Sampaio 27 March 2009 (has links)
O objetivo deste trabalho foi comparar, por meio de teste de microdureza e técnicas de caracterização metalúrgica, que inclui a metalografia, microscopia óptica, microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (energy dispersive spectroscopy EDS), propriedades mecânicas e metalúrgicas de juntas soldadas pelos métodos TIG e brasagem em uma liga odontológica à base de Ni-Cr (FIT-CAST SB). As regiões estudadas em cada amostra foram o metal de base (MB), a zona termicamente afetada (ZTA) e a zona de fusão (ZF). Foram confeccionados 40 corpos-de-prova cilíndricos, em forma de bastão, com 2,5mm de diâmetro e 18,0mm de comprimento, obtidos apartir de fundição odontológica por centrifugação (técnica da cera perdida). Foram separados vinte cilindros para cada técnica, que após a soldagem formaram grupos de dez amostras para cada procedimento. A microestrutura do MB apresentou-se como uma matriz de uma solução sólida à base de Ni-Cr contendo um típico arranjo dendrítico de estrutura eutética. A liga apresentou precipitados metálicos na região interdendrítica da estrutura eutética. A análise química semi-quantitativa obtida através da técnica de EDS apresentou resultados compatíveis com a composição química quantitativa fornecida pelo fabricante da liga. Na brasagem, o MB e a ZF apresentaram microestruturas distintas. A ZF apresentou uma morfologia dendrítica grosseira com a presença de precipitados e porosidades. A análise química semiquantitativa por EDS da ZF mostrou-se bastante semelhante aos resultados obtidos para o MB. Nos corpos de prova unidos pelo processo de brasagem, a média de microdureza Vickers para o MB, a ZTA e a ZF foram respectivamente 83,501, 87,782 e 127,520. A análise estatística t-Student revelou diferenças significativas entre as regiões MB e ZF. No processo TIG, a microestrutura da ZF apresentou aspecto semelhante a do MB, porém, com o arranjo dendrítico mais refinado. A análise química semiquantitativa por EDS da ZF apresentou resultados semelhantes aos obtidos para o MB. Os corpos de prova apresentaram média de microdureza Vickers para o MB, a ZTA e a ZF respectivamente de: 74,607, 71,649 e 75,409. A análise estatística t-Student não revelou diferenças significativas entre as regiões analisadas. De acordo com a metodologia aplicada neste estudo e apartir da análise estatística dos dados obtidos, pode-se concluir que: o processo de união por brasagem gerou diferenças microestruturais e de microdureza Vickers entre a ZF e o MB; nas juntas soldadas pelo método TIG, os ensaios de microdureza Vickers revelaram uniformidade no comportamento mecânico entre a ZF, a ZTA e o MB; o processo de soldagem TIG gerou uma microestrutura bem semelhante entre a ZF e o MB e acarretou naquela apenas um arranjo dendrítico de estrutura eutética mais refinado; a análise química por EDS revelou que não houve variação de composição química significativa entre o MB e a ZF das juntas soldadas por ambos os métodos. / The purpose of this study was to compare, by means of microhardness testing and metallurgical characterization techniques as metallography, optical microscopy, scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS), mechanical and metallurgical properties of welded joints by TIG and brazing methods in a dental alloy based on Ni-Cr (FIT-CAST SB). The studied regions in each sample were the base metal (MB), the heat affected zone (ZTA) and the fusion zone (ZF). Forty cylindrical bodies-of-proof, stick-shaped, with 2.5mm diameter and 18.0mm in length were made from dental casting by centrifugation (lost wax technique). Twenty cylinders were used for each technique, which formed, after the welding, groups of ten samples for each procedure. The microstructure of the MB is presented as a matrix of a solid solution based on Ni-Cr with a typical dendritic arrangement of eutectic structure. The alloy presented metallic precipitates in the interdendritic region of the eutectic structure. The semiquantitative chemical analysis obtained by EDS technique showed results consistent with the quantitative chemical composition provided by the alloy manufacturer. In the brazing method, the MB and ZF showed different microstructures. The ZF showed a rough dendritic morphology with the presence of precipitates and porosities. The semiquantitative chemical analysis by EDS of the ZF had very similar results to those obtained for the MB. In the bodies-of-proof joined by the brazing process, the average Vickers microhardness for the MB, ZTA and ZF were respectively 83.501, 87.782 and 127.520. The t-Student statistical analysis revealed significant differences between the MB and ZF regions. In the TIG process, the microstructure of ZF presented similar aspect to the MB, but with a more refined dendritic arrangement. The semiquantitative chemical analysis by EDS of ZF presented similar results to those obtained for the MB. The bodies-of-proof had an average Vickers microhardness of the MB, ZTA and ZF respectively: 74.607, 71.649 and 75.409. The t-Student statistical analysis revealed no significant differences between the studied regions. According to the methodology applied in this study and from the statistical analysis of the obtained data, we can conclude that the process of union by brazing created microstructural and Vickers microhardness differences between the ZF and MB; in welded joints by the TIG method, the Vickers microhardness tests showed uniformity in the mechanical behavior among the ZF, ZTA and MB; the TIG welding process generated a very similar microstructure between the ZF and MB and made on that just a dendritic arrangement of more refined eutectic structure; the EDS chemical analysis revealed that there was no significant change in the chemical composition between the MB and ZF of welded joints by both methods.
20

Efeito da aplicação de carga em coroas de diferentes materiais, confeccionadas sobre implantes unitários curtos e com diferentes diâmetros nas deformações da crista óssea : análise in vitro e in silico / Effect of the load application on crowns of different materials made on short unitary implants with different diameters in bone crest deformations : in vitro and in silico analysis

Monteiro, Fabricio Malheiros de Miranda 25 June 2018 (has links)
Submitted by Fabricio Malheiros de Miranda Monteiro (drfabriciomalheiros@hotmail.com) on 2018-07-18T02:33:45Z No. of bitstreams: 2 Dissertação final Fabricio - Após defesa PDF.pdf: 2296763 bytes, checksum: ed270b35065a6429cbde4e2e753d6939 (MD5) Verso - Contra capa.pdf: 2579 bytes, checksum: 284cd58d1fec7c9b0fd7c0cc97473d8b (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-07-18T18:10:35Z (GMT) No. of bitstreams: 1 monteiro_fmm_me_sjc.pdf: 2237869 bytes, checksum: 8ae93eb96970a513787047d5630ce786 (MD5) / Made available in DSpace on 2018-07-18T18:10:35Z (GMT). No. of bitstreams: 1 monteiro_fmm_me_sjc.pdf: 2237869 bytes, checksum: 8ae93eb96970a513787047d5630ce786 (MD5) Previous issue date: 2018-06-25 / O intuito deste estudo in vitro e in silico, foi analisar as microdeformações, geradas pela aplicação de carga vertical, sobre coroas de 3 tipos de materiais restauradores diferentes (Zircônia, Dissilicato de Lítio e Cromo Cobalto), que foram selecionadas, através da biblioteca do software SMART DENT/Exocad (Darmstadt - Germany) e confeccionadas, através da tecnologia cad/cam, suportadas por implantes curtos (8mm), conexão cone morse, com diversos diâmetros (3,5 mm; 4,0 mm e 5,0 mm). Os implantes foram instalados 2mm infraósseo para análise através de elementos finitos e da extensometria. Foram confeccionados 3 blocos de poliuretano: bloco 1 (grupo experimento) no qual foi colocado um implante Titamax CM Neodent 3,5 X 08 mm, bloco 2 (grupo controle) no qual foi colocado um implante titamax CM Neodent 4,0 X 08 mm e bloco 3 (grupo controle) no qual foi colocado um implante titamax CM Neodent 5,0 X 08 mm. Pilares protéticos retos (Base de Titânio 4,5 - Neodent) foram instalados sobre os respectivos implantes sendo instalados 4 extensômetros, na região superior dos blocos ao redor dos implantes. Foi aplicada uma carga vertical de 300N ao redor da abertura de acesso do parafuso protético das coroas. Para a análise por elementos finitos (FEA), o mesmo bloco foi modelado e analisado sob a mesma carga de 300N. Os valores de tensão e deformação foram analisados quanto à correlação com a extensometria. A estatística inferencial consistiu no teste de análise de variância de Friedmann, um fator efeito fixo. Para o nível de significância, foi escolhido o valor convencional de 5%. Os resultados demonstraram haver diferença estatística significante para o fator diâmetro (p = 0,0001) no qual os implantes, com 3,5 mm de diâmetro apresentaram os maiores picos de microdeformações. Quando se analisa o material restaurador, observa-se que não houve diferenças estatísticas significativas (p = 0,783). Dentro das limitações deste estudo, pode-se concluir que a utilização de implantes unitários, curtos e estreitos com conexão cone morse instalados 2 mm infraósseo, são uma opção viável para reabilitações em regiões posteriores independente do material restaurador escolhido. / The aim of this in vitro and in silico study was to analyze the microdeformations generated by the application of vertical load on crowns of 3 different types of restorative materials (Zirconia, Lithium Dissilicate and Cobalt Chromium) that were selected through the software library SMART DENT / Exocad (Darmstadt - Germany), and made using cad / cam technology, supported by short implants (8 mm), cone morse connection with various diameters (3.5 mm, 4.0 mm and 5.0 mm). These were installed 2 mm subcrestal for finite element analysis and extensometry. Three blocks of polyurethane were made; block 1 (experimental group) in which a Titamax CM Neodent 3.5 X 08 mm implant, block 2 (control group) was implanted in which a CM Neodent 4.0 X 08 mm titamax and block 3 (control group) were implanted in which an implant was placed titamax CM Neodent 5.0 X 08 mm. Straight prosthetic abutments (Titanium Base 4.5 - Neodent) were installed on the respective implants and 4 extensometers were installed, in the upper region of the blocks around the implants. A vertical load of 300N was applied around the access opening of the crown prosthetic screw. For the finite element analysis (FEA), the same block was modeled and analyzed under the same 300N load. The stress and strain values were analyzed for correlation with extensometry. The inferential statistics consisted of Friedmann's analysis of variance, a fixed effect factor. For the level of significance, the conventional value of 5% was chosen. The results showed a statistically significant difference for the diameter factor (p = 0.0001) where 3.5 mm diameter implants presented the highest peaks of microdeformations. When analyzing the restorative material, we observed that there were no significant statistical differences (p = 0.783). Within the limitations of this study, we can conclude that the use of short, narrow unit implants with cone morse connection installed 2 mm subcrestal are a viable option for rehabilitation in posterior regions independent of the restorative material chosen.

Page generated in 0.2553 seconds