• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 742
  • 228
  • 217
  • 96
  • 62
  • 49
  • 35
  • 35
  • 35
  • 35
  • 35
  • 34
  • 19
  • 12
  • 9
  • Tagged with
  • 1819
  • 919
  • 230
  • 214
  • 213
  • 173
  • 167
  • 122
  • 102
  • 93
  • 92
  • 87
  • 86
  • 84
  • 79
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
441

Fuktrelaterade risker vid lågenergikonstruktion i lättbetong : En studie av ett nyproducerat passivhus / Moisture related risks with aerated concrete in low energy constructions : A study of a newly produced passive house

Jansson, Sebastian, Niklasson, Erik January 2014 (has links)
Trenden i byggbranschen är att efterfrågan på täta, energisnåla byggnader ökar. Passivhus och andra lågenergikonstruktioner blir vanligare och vanligare. Riskerna med att bygga in organiskt material som trä i dessa konstruktioner har fått branschen att börja titta på alternativa material. Lättbetong är ett material som både har bärande och isolerande egenskaper. Dessutom är det inte organiskt vilket gör det okänsligt för mikrobiell påväxt. Det som är intressant med lättbetong, ur fuktsynpunkt, är att materialet levereras från tillverkare med en stor mängd byggfukt. Våren 2014 färdigställde Bollnäs Bostäder passivhus- projektet Sundsbro i Bollnäs, där lättbetong ingår i utfackningsväggarna. Sett inifrån består väggen av ett tunt lager kc-puts, lättbetong, cellplast, mineralull, kc-baserad grovputs och ytputs. I detta arbete användes projektet i Bollnäs som referensobjekt och en risk- och känslighetsanalys av väggkonstruktionen utfördes. Arbetet utreder risken för fuktrelaterade problem med väggen vid de extra uttorkningsinsatser som vidtogs i referensobjektet och vid normala uttorkningsbetingelser. Vidare utreds vilka parametrar som är viktiga för väggens fuktfunktion och vad man behöver tänka på när man projekterar och bygger i lättbetong. Arbetet har genomförts i samarbete med AK-Konsult Indoor Air AB och deras senior konsult Anders Kumlin. Fuktberäkningsprogrammet WUFI Pro 5.3 har använts för simuleringar. Beräkningarna gjordes endimensionellt på väggkonstruktionen. Resultaten med den ökade uttorkning som utfördes i referensobjektet visar inget högre fuktinnehåll längst ut i väggen på grund av byggfukt från lättbetongen som vandrar utåt. Farhågan var att så skulle kunna ske och att det skulle kunna leda till mögelproblem. Däremot visar resultaten att bygg-fukt från putsen kan fukta upp mineralullen. Det finns dock inga kända skadefall av detta slag och därför dras ändå slutsatsen att konstruktionen är riskfri. Tack vare en förutseende fukt-projektering och väl utförd uttorkning eliminerades risken för mögel. Hade inte dessa åtgärder vidtagits så visar resultaten att en liten mängd byggfukt hade kunnat vandra utåt och kondensera i mineralullen under första vintern. Då hade det funnits risk för mikrobiell påväxt. Detta visar att det är av största vikt att utföra en noggrann fuktprojektering vid byggnation av välisolerade hus i allmänhet och i synnerhet när lättbetong används. Lyckligtvis gjordes detta på ett bra sätt i referensprojektet. Känslighetsanalysen visar att isoleringens diffusionstäthet är avgörande för hur stor del av bygg-fukten som kan vandra utåt och därmed hur stor risken för problem blir. Lägre täthet ger större risk och högre täthet reducerar risken. Resultaten visar också att det är viktigt att inte montera täta skikt på insidan för tidigt. Den allmänna rekommendationen från leverantör är att lättbetongen skall torkas till 15 % fuktkvot på 50 millimeters djup innan målning och tapetsering på insida vägg får ske. Studien visar att detta är ett för högt fukttillstånd om det skikt som appliceras på insida vägg är tätt. Lättbetongen bör torkas till 5 % på 50 millimeters djup innan helt täta skikt kan monteras utan mögelrisk. / The trend in the construction industry is that the demand for tight, energy-saving buildings is rising. Passive houses and low energy constructions are becoming more and more common. The risk with using organic material in this type of constructions has made the industry look at alternative materials. Aerated concrete is a material that has both load-bearing and insulating properties. In addition to that it is not organic, which makes it insensitive to microbial growth. What is interesting with aerated concrete, from a moisture point of view, is that the material is delivered from the producer with a large amount of construction moisture. In the spring of 2014, the passive-house project Sundsbro in Bollnäs with aerated concrete in the wall construction, was finished by Bollnäs Bostäder. In this study the project in Bollnäs was used as reference object and a risk- and sensitivity analysis was made. The study examines the risk of moisture related problems with the wall construction during normal dehydration conditions and after the increased dehydration efforts that were taken in the reference project. The study also examines which parameters are important for the moisture function of the wall construction and what you need to think about when you project and build with aerated concrete. The job has been done in cooperation with AK-Konsult Indoor Air AB and their senior consultant Anders Kumlin. The moisture calculation program WUFI Pro 5.3 has been used for simulations. The results with the increased dehydration that was used in the reference project show no increased moisture content in the outer parts of the construction due to construction moisture from the concrete that wanders outwards. The concern was that so could happen and that it would lead to mould problems. However the results show that construction moisture from the exterior plaster can moisten the mineral wool. There are no known damage cases of this sort and therefore the conclusion is that the construction is free of risk. Thanks to a foreseeing moisture projection and a well performed dehydration the risk of mould was eliminated. If these measures would not have been taken, the results show that a small amount of construction moisture could have wandered outwards and condensed inside the mineral wool during the first winter. Then there would have been a risk of microbial growth. This shows that it is very important to carry out a detailed moisture projection when constructing well insulated houses in general and when using aerated concrete in particular. Fortunately this was properly done in the reference project. The sensitivity analysis shows that the diffusion resistance of the insulation decides how much of the construction moisture that can wander outwards and consequently the size of the problem risk. Results also show that it is crucial not to apply sealing layers on the inside of the wall too early. The general recommendation from the supplier is that the aerated concrete should be dried to 15 % moisture ratio on 50 millimeter depth before painting and paper hanging on the interior surface of the wall can be done. The study shows that the concrete still is too damp at that stage if the layer applied on the inside of the wall is impermeable. The concrete should be dried down to 5 % moisture ratio before sealing layers can be applied without mould risk.
442

Fuktproblem i produktionsskedet : Förebyggande åtgärder och åtgärder efter fuktskada

Andersson, Jasmine, Mård, Oliver January 2023 (has links)
Purpose: The purpose of this study is to examine the problems that occur due to moist in the workplace, as well as the measures that can be taken and which measures are most effective. The study will examine the material storage and how it is being handled in the workplace, exploring what directives the insurance companies have, so the insurance is valid. Lastly the study will compare the different measures based on an economic perspective, time perspective as well as material savings. Method: This study is based on a literature study and a case study. The case study is based on both an interview and a site visit. Information has been gathered from various sources such as books, previously made thesis and various governments websites. The case study for this thesis is conducted at Emausskolan in Västerås. Results: To ensure that the moisture management in the production is good a certified moisture expert is hired. Moisture on materials can be prevented by using just-in-time deliveries and the most optimal solution a weather protection. Directives from the insurance companies regarding moisture management at the workplace and what the entrepreneur is obligated to do after moisture damage has occurred. To minimize moisture and mold growth the workplace should be clean and dry. Self-monitoring and samples were carried out throughout the project to ensure that the work has been performed correctly. Conclusions: The conclusion for this thesis is that challenges for moisture depends on the weather, carelessness, and time pressed schedules. Solutions would be to have a tight climate shell, usage of weather protection and surface treatment on materials. Handling of materials is to a certain degree taken care of in terms of palletized and packaged but not always.
443

Torkklimat under byggproduktion : En kvantitativ studie baserad på klimatdata och litteraturstudier / Drying climate during construction condition : A quantitative study based on climate date and literature studies

Sidenqvist, Daniel, Ternstedt, Viktor January 2014 (has links)
En utmaning under produktionen är uttorkning av byggfukt i byggnadens betongbjälklag. Om uttorkningen försenas kan golvbeläggningar inte appliceras i rätt tid, men att arbetet forceras är inte ett alternativ, då risken finns att fuktskador uppkommer under driftsskedet. Avgörande för att uttorkningen skall fortskrida enligt plan är att torkklimatet i byggnaden är gynnsamt för uttorkningsprocessen. För att kontrollera torkklimatet genomför företaget ett omfattande arbete genom att mäta klimatet, där dataloggar på olika platser i byggnaden registrerar luftens temperatur och relativa fuktighet. Tillsammans med trendmätningar i betong är tanken att insamlad data skall ge en bild av hur uttorkningen fortskrider. Svårigheten med torkklimat är att ämnesområdet i många avseenden är abstrakt och teoretiskt, just därför att parametrarna som beskriver torkklimatet ständigt varierar. För att insamlad data skall addera värde för produktionen måste datamängderna analyseras och visualiseras på ett tydligt sätt, som medför att produktionsledningen kan agera utifrån informationen utan att nödvändigtvis besitta spetskompetens inom ämnesområdet. Examensarbetet syftar till att bistå företaget med ökade kunskaper om torkklimat under byggproduktion, kopplat till uttorkning av byggfukt. Under arbetet har förutsättningarna för en effektiv uttorkning studerats, med avseende på torkklimatets variation. Under arbetet har också en undersökning gjorts för att ta reda på när företaget i ett generellt fall bör komplettera torkklimatet med ökad ventilation och/eller avfuktning för att hålla ett jämnt torkklimat i byggnaden året om. Som bakgrund till ämnesområdet redovisas en beskrivning av de styrande faktorerna för torkklimatet, teoretiskt och projektspecifikt. Resultatet av studien visar att förutsättningarna för en effektiv uttorkning har funnits på de platser i byggnaden som studerats, i det avseendet att en majoritet av klimattrenderna följer uppsatta kriterier i projektets fuktsäkerhetsplan.  Studien visar också att en komplettering med ökad ventilation och/eller avfuktning bör starta under perioden mars till april och under oktober till november kan uttorkningsstrategin återgå till att enbart värma inomhusluften. / A challenge during construction is drying of construction moisture in the building's concrete slab. If the drying is delayed, the flooring can’t be applied at the right time, but forcing the process is not an option, because of the risk of moisture damage during the operating phase. Crucial to the planed drying is that the climate in the building is favorable for the drying process. In order to control the drying climate the company is conducting an extensive work by measuring, where data logs at different locations in the building records air temperature and relative humidity. Along with the trend measurements of moisture levels in the concrete slab, the idea is that the data series should provide a picture of how the drying progresses. The difficulty with drying climates is that the subject in many respects is abstract and theoretical, because the parameters that describe the drying climate are continuously changing. If the collected data should add value to the construction site, the amount of data needs to be analyzed and visualized in a clear way, which means that the company's construction management services can act based on the information without necessarily possessing expertise in the subject area. This bachelor degree project aims to assist the company with knowledge of drying climate during construction condition, linked to the drying of construction moisture. During the work, the conditions for effective drying of construction moisture have been studied with respect to variations in drying climate.  Another study also conducted, was to find out when the company in a general case may complement drying climate with increased ventilation and/or dehumidification to keep the drying climate at a steady level in the building year round. As background to the subject, a description of the factors controlling the drying climate is presented in the report, theoretical and specifically for the project. The results of the study show that the conditions for effective drying of construction moisture have been the case of the building sites that has been sampled, in the sense that a majority of climate trends follow the established criteria in the project's moisture safety plan. The study also shows that increased ventilation and/or dehumidification may be applied as a supplement in the period from March/April until October/November at which time the dehydration strategy can revert back to warming indoor air only.
444

Soil Moisture Sensing in Mining Waste Rock: Comparing Calibration Curves of Multiple Low-Cost Capacitance Sensors and a Single TDR Sensor / Mätning av vatteninnehåll i gruvavfall: En jämförelse av kalibreringskurvor för flera billiga kapacitanssensorer och en enda TDR-sensor

Jørgensen, Rasmus January 2022 (has links)
Measuring soil moisture content (SMC) in mining waste rock is important for assessing and modelling hydrological processes which influence pollutant release. Here, an experimental setup containing mining waste rock is established to compare the performance of 4 Arduino capacitance moisture sensors to one single Time Domain Reflectometry (TDR) sensor. Furthermore, the performance of these sensors is evaluated in both sieved and unsieved mining waste rock. Fitted calibration curves are provided for both the TDR- and Arduino-sensors individually and in combination. These calibration curves are evaluated using the RMSE and R 2 of each curve and compared between sensors and soil texture. It is concluded that using more capacitance sensors significantly improves the fit statistics of the calibration curves and that using at least 4 capacitance sensors can enhance calibration curve fitting. For both the TDR and capacitance sensors, the calibration curves in sieved soil provided the best fit, meaning that soil specific calibration of sensors is recommended. On a sensor individual basis, the temporal precision of the TDR sensor was superior to each individual capacitance sensor. Use of 4 or more Arduino capacitance sensors may especially be justified in circumstances where the spatial variability of SMC is addressed by executing a large number of measurements. Here, the feasibility of the Arduino sensor system means that the use of these low-cost sensors, despite their reduced temporal precision, can be upscaled at relatively small costs.
445

The influence of production practices on agronomic performance and components of yield and examination of genetic diversity for leaf canopy temperature in soybeans

Harris, Dorothy Sue January 2011 (has links)
Typescript (photocopy). / Digitized by Kansas Correctional Industries
446

Effects of corn sweeteners on cookie quality

Curley, Lynn Patricia January 2011 (has links)
Typescript (photocopy). / Digitized by Kansas Correctional Industries
447

Studies of electronic moisture meter performance on freshly harvested grains in Kansas

Koch, Kim January 2011 (has links)
Digitized by Kansas Correctional Industries
448

Field and laboratory studies of lodging and drouth resistance in corn

Hunter, James William. January 1935 (has links)
Call number: LD2668 .T4 1935 H81
449

The prevention of moisture migration in winter stored wheat

Ordoveza, Juanito L. January 1954 (has links)
LD2668 .T4 1954 O74 / Master of Science
450

Water movement in a stratified soil

Saadi, Abdelhakim. January 1984 (has links)
Call number: LD2668 .T4 1984 S22 / Master of Science

Page generated in 0.0195 seconds