• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 220
  • 5
  • 4
  • 1
  • Tagged with
  • 231
  • 148
  • 89
  • 76
  • 52
  • 51
  • 47
  • 41
  • 40
  • 37
  • 36
  • 35
  • 35
  • 34
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Implementação de um instrumento para medição da intensidade de fótons na faixa da mamografia /

Andreazzi, Mariana. January 2018 (has links)
Orientador: Aparecido Augusto de Carvalho / Resumo: Foi implementado um instrumento com a finalidade de medir a intensidade (taxa de fluência de energia) de fótons na faixa de mamografia (22 a 33 kVp) e a tensão do tubo de um mamógrafo. O instrumento é constituído por uma câmara com sensor piroelétrico de metaniobato de chumbo (PbNb2¬O¬¬6) e seu circuito de condicionamento de sinais. Utilizou-se poliácido lático para confeccionar a câmara piroelétrica em uma impressora 3D. O circuito de condicionamento de sinais é um conversor corrente-tensão de alta sensibilidade. A intensidade da radiação foi determinada a partir da taxa de exposição medida com uma câmara de ionização. Uma simulação do espectro de emissão do molibdênio, na faixa de 22 a 33 kVp, foi realizada com o sensor piroelétrico e o software DTSA-II, e comparada com a o feita com um sensor de Si(Li), comumente empregado. Os resultados obtidos mostram que a resposta do instrumento implementado é linear com a tensão do tubo de raios-X e com a intensidade da radiação, e que o espectro de emissão do molibdênio pode ser determinado com o instrumento piroelétrico. / Abstract: An instrument to measure the intensity (energy fluence rate) of photons in the mammography range (22 to 33 kVp) and the tube voltage of a mammograph. The instrument consists of a chamber with a pyroelectric sensor of lead methaniobate (PbNb2O6) and its signal conditioning circuit. Polyacid was used to make the pyroelectric chamber in a 3D printer. The signal conditioning circuit is a high sensitivity current-voltage converter. The intensity of the radiation was determined from the exposure rate measured with an ionization chamber. A simulation of the emission spectrum for molybdenum, in the range of 22 to 33 kVp, was performed with the pyroelectric sensor and the DTSA-II software, and compared to that simulated using the commonly used Si (Li) sensor. The results show that the response of the implemented instrument is linear with the X-ray tube voltage and the intensity of the radiation, and that the emission spectrum of molybdenum can be determined with a pyroelectric instrument. / Mestre
52

Investigações em processamento de imagens mamográficas para auxílio ao diagnóstico de mamas densas / Investigations on processing of mammografic images to aid diagnosis of dense breasts

Marques, Fátima de Lourdes dos Santos Nunes 13 July 2001 (has links)
Esquemas de diagnóstico auxiliado por computador (CAD, do inglês \"computer aided diagnosis\") têm sido desenvolvidos com o objetivo de fornecer subsídios para a detecção precoce do câncer de mama. Nesses esquemas, técnicas de processamento de imagens são utilizadas para indicar a existência de estruturas suspeitas em imagens mamográficas. Entre essas estruturas estão os agrupamentos de microcalcificações (clusters), cuja existência é indicativo da necessidade de uma inspeção mais minuciosa no local. As imagens de mamas densas, características principalmente de mulheres jovens, constituem, no entanto, um desafio para esses esquemas devido ao baixo contraste entre as estruturas de interesse e os demais tecidos representados na imagem mamográfica. Nesta pesquisa, portanto, foram feitas investigações sobre as características das imagens radiográficas de mamas densas, a partir das quais foram desenvolvidas técnicas de realce de contraste que, somadas a outras técnicas de processamento digital, proporcionaram um desempenho mais apropriado de um esquema de processamento para detecção de c1usters. Foram ainda elaboradas técnicas que permitam o trabalho com uma resolução de contraste mais adequada, além de outras que consideram alguns dos parâmetros físicos envolvidos na obtenção das imagens e procedimentos para reduzir diagnósticos falsos-positivos. Os resultados registrados nos testes com diferentes conjuntos de imagens de uma base de dados montada para esse projeto indicam que a combinação das técnicas desenvolvidas permite incrementar o desempenho de um esquema de processamento para detectar agrupamentos de microcalcificações, possibilitando a identificação de estruturas em imagens de baixo contraste, não detectadas em processamento convencional antes do realce de contrate. Como efeito, essa investigação mostra a possibilidade de esquemas CAD em mamografia atingir agora desempenho satisfatório na detecção de microcalcificações em imagens de mamas densas. / Computer-aided diagnosis (CAD) schemes have been developed intended to provide information for early detection of breast cancer. Image processing techniques are used in these schemes in order to indicate suspicious structures in mammographic images. Among these structures there are clustered microcalcifications, which usually drive to a more detailed examination in the location where they are. Images corresponding to dense breasts, which are characteristic mainly of young women, are however a challenge to CAD schemes due to the low contrast between the structures of c1inical interest and the other tissues registered on the film. Therefore, investigations were performed in this work on the characteristics of dense breasts radiographic images, from which contrast enhancement techniques were developed. These procedures were joined to other digital processing techniques to provide a better performance for a processing scheme intended to clusters detection. In addition, techniques which allow to work with a more suitable contrast resolution and others which take into account some of the physical parameters involved in the image acquisition process were developed together with a procedure designed to reduce false positive diagnoses. The results obtained during tests with different images sets from a data base developed for this research indicate that combining all the techniques developed here allow to improve the performance of a processing scheme designed to detect microcalcifications clusters, and it also allows to distinguish some of these structures in low contrast images, which were not detected in conventional processing before the contrast enhancement. As consequence, this investigation shows the possibility now for CAD schemes in mammography reaches a better performance in microcalcifications detection in dense breasts images.
53

Análise de materiais biológicos usando o coeficiente de atenuação linear / Biological Material Analisis using linear attenuation coefficients

Soares, Leonardo Diniz Hipolito 27 October 2015 (has links)
O conhecimento do coeficiente de atenuação linear (µ) é de extrema importância para estudos de contraste em imagens de radiodiagnóstico, dose e caracterização de materiais. Parâmetros como a densidade eletrônica (?e), o número atômico médio (Z¯), entre outros, podem ser determinados a partir do coeficiente de atenuação linear em diferentes energias. A proposta deste trabalho é determinar experimentalmente coeficientes de atenuação linear de 80 amostras de tecidos mamários (classificadas previamente como tecido adiposo, tecido glandular, fibroadenoma ou carcinomas) e, posteriormente, extrair parâmetros que possibilitem a caracterização e diferenciação desses tecidos. Os coeficientes de atenuação linear foram medidos usando geometria de feixe estreito, no intervalo de energia entre 10 e 50 keV, utilizando um tubo de raios X com anodo de tungstênio (W) e um detector dispersivo em energia de Si (SDD). Dois modelos de parametrizações foram utilizadas para extrair ?e e Z¯. As metodologias de determinação de µ e de parametrização foram validadas utilizando 8 materiais equivalentes a tecido (4 soluções e 4 sólidos). Os resultados obtidos para tecidos mamários foram comparados com predições teóricas, obtidas usando a regra das misturas, e com dados experimentais previamente publicados, apresentando diferenças máximas de até 7%. Foram também estudadas as variações de µ intra- e inter-amostras de um mesmo grupo, obtendo variações máximas de 5% e 12%, respectivamente. Foi mostrado que o coeficiente de atenuação linear consegue distinguir apenas o tecido adiposo dos demais grupos de tecidos para energia menores de 24 keV. Finalmente, foi elaborado um modelo de diagnóstico, baseados nos parâmetros ?e e Z¯. As análises estatísticas mostram que 71% das amostras foram classificadas corretamente. / The knowledge of the linear attenuation coefficient (µ) is of extreme importance for radiodiagnostic image contrast studies, dose and material characterization. Parameters as electronic density (?e), average atomic number (Z¯), among others, can be determined using the linear attenuation coefficient at different energies. The purpose of this work is to experimentally determine the linear attenuation coefficient of 80 mammary tissues samples (classified as adipose tissue, glandular tissue, fibroadenoma or carcinoma) and then extract parameters that allow the characterization and differentiation of those tissues. The linear attenuation coefficients were measured using narrow bean geometry, with an energy interval between 10 and 50 keV, using a x-ray tube with a tungsten (W) anode and a Silicon energy dispersive detector (SDD). Two parameterization models were used to extract ?e and Z¯. The methodologies of determination of µ and parameterizations were validated using 8 tissue equivalent materials (4 solutions and 4 solids). The results obtained for mammary tissues were compared with theoretical predictions, using the mixture rule, and with previously published experimental data, presenting maximum differences of 7%. Intra and between samples variations of the same group were also studied, obtaining maximum variations of 5% and 12%, respectively. The linear attenuation coefficient was able to differentiate only the adipose tissue from others tissues groups, for energies below 24 keV. At last, a diagnostic model was elaborated, based on ?e and Z¯ parameters. The statistical analysis showed that 71% of the samples were correctly classified.
54

Investigações sobre digitalização de imagens mamográficas: padronização da qualidade da imagem e seu efeito no desempenho de esquemas de processamento / Investigations on scanning mammography: standardization of image quality and its effect on performance of processing schemes

Góis, Renata de Freitas 20 December 2010 (has links)
Este trabalho trata, inicialmente, de uma extensa investigação acerca do efeito que o processo de digitalização da imagem exerce num esquema de processamento de imagens em mamografia. Como todas as etapas de processamento tomam por base a imagem original digitalizada, os diferentes equipamentos, tecnologias, softwares de aquisição e características do processo contribuem para produzir diferentes aspectos na digitalização de um mesmo filme mamográfico. Por conseguinte, as etapas envolvidas do pré-processamento à classificação, passando principalmente pela segmentação dessas imagens, poderão produzir diferentes resultados dependendo da fidelidade da imagem digital em relação à mamografia original. Assim, essa pesquisa focaliza uma avaliação comparativa das características das imagens mamográficas adquiridas em diferentes sistemas de digitalização, tomando por base o efeito que esse processo exerce na sensibilidade de módulos de um esquema CAD (de Computer-Aided Diagnosis) previamente desenvolvido em nosso grupo. Com base nisso, propõe-se um modelo computacional que permite compensar as eventuais degradações introduzidas no processo de digitalização, em busca de uma maior uniformidade das imagens mamográficas digitais, independentemente do equipamento utilizado na digitalização. Testes conduzidos com as imagens digitais geradas em vários sistemas diferentes - desde equipamentos mais comuns, com adaptadores de transparência, até os mais sofisticados, com varredura a laser, e de alto custo - utilizando o driver de digitalização aqui proposto mostraram que houve um aumento da sensibilidade na detecção de microcalcificações para todos os casos em relação à utilização das imagens originalmente digitalizadas sem a aplicação do modelo. Além disso, foi significativa também a redução na taxa de falsos-positivos (entre 70 e 90%) nas mesmas condições. Como efeito, a presente proposta torna acessível a qualquer instituição radiológica a possibilidade de aplicação de esquemas de processamento para auxiliar a detecção e/ou diagnóstico de estruturas suspeitas em mamografia, mesmo que utilizando digitalizadores menos sofisticados - e, portanto, de menor custo - para a produção das imagens mamográficas digitais e sem perda de qualidade do desempenho. / This work corresponds to an extensive investigation on the effect of the image digitization process on an image processing scheme in mammography. As all the processing steps are based on a digitized image, different equipment, technologies, acquisition softwares and characteristics regarding such a procedure contribute to yield different features during the digitization of a same mammographic film. As a consequence, all the steps since the pre-processing up to the classification, mainly the images segmentation, could give different results depending on the digital image fidelity relatively to the original mammogram. Therefore, this research concentrates on a comparative evaluation of mammographic images acquired from several digitization systems, concerning the effect of this procedure on the sensitivity of a CAD scheme sections previously developed in our research group. A computer model is proposed in order to compensate some flaws introduced in the digitization procedure. The purpose is assuring more uniformity to the digital mammography images, no matter the digitizer used. Tests with digital images from several different systems - since common equipment, with transparency adaptors, up to the most expensive and sophisticated, with laser scanning - by using the digitization driver proposed in this work have shown an increase in microcalcifications detection sensitivity for all cases relatively to the use of original digitized images without making use of the proposed model. Furthermore, the reduction in false positive rates was significant (from 70% up to 90%) in the same conditions. Therefore, the current application makes possible to any radiological institution the use of processing schemes to aid the detection and/or diagnosis of suspect structures in mammography, even using less sophisticated - and thus, with low cost - digitizers and keeping the performance quality.
55

Avaliação do impacto de exercícios físicos na redução da dor em mulheres submetidas à mamografia / Evaluation of physical exercise impact on pain reduction in women subjected to mammography

Almeida, Tadeu Cardoso de 24 February 2015 (has links)
Introdução: O câncer de mama é a maior causa de morte em mulheres pela doença em todo o mundo. O rastreamento pela mamografia e o exame clinico anual das mamas são estratégias recomendadas para o seu controle. Um dos motivos pouca adesão das mulheres aos programas de prevenção é a dor associada à mamografia. Objetivo: Avaliar a eficácia do exercício físico orientado realizado antes da realização do exame de mamografia, na redução da dor percebida após o exame. Métodos: Trata-se de um ensaio clínico aberto, randomizado, controlado, cuja intervenção foi uma sequencia de exercícios físicos de aquecimento e alongamento em membros superiores e inferiores em mulheres atendidas pelo Departamento de Prevenção do Hospital de Câncer de Barretos. As mulheres foram divididas em três grupos, grupo com intervenção em membros superiores (grupo 1), grupo com intervenção em membros inferiores (grupo 2) e grupo sem intervenção (Grupo 0). Foram realizadas comparações entre variáveis quantitativas intra e intergrupos através de ANOVA e teste t de Student com nível de significância de 5%, bem como, realizado cálculo de risco relativo e medidas dele derivadas. Resultados: 198 mulheres foram avaliadas (66 mulheres em cada grupo), os dados sóciodemográficos, assim como o nível de atividade física não foram associados à percepção de dor após o exame de mamografia, no entanto a intervenção com exercícios físicos levou à menor percepção da dor após o exame, quando comparado aos grupos 2 e 0. Conclusão: Os exercícios físicos de aquecimento e alongamento pré-exame, foram eficazes diminuindo a percepção e sensação à dor entre mulheres que tiveram a intervenção em membros superiores, no entanto, observou-se ainda que as mulheres sob intervenção em membros inferiores também apresentaram resultados de menor percepção à dor quando comparado com o grupo controle. / Introduction: Breast cancer is the leading cause of death by disease in women worldwide. Screening by mammography and annual clinical breast exams are recommended for their control strategies. One of the reasons for poor adherence of women to prevention programs is the pain associated with mammography. Objective: To evaluate the efficacy of exercise conducted prior to the mammogram in the reduction of perceived pain after the procedure. Methods: This was an open, randomized, controlled clinical trial, whose intervention was a sequence of exercises for warming up and stretching in the upper and lower in women attending the Prevention Department of Barretos Cancer Hospital/Brazil. The women were divided into three groups, the intervention group in the upper limbs (group 1), the intervention group in the lower limbs (group 2) and without intervention group (Group 0). Comparisons between intra and inter quantitative variables using ANOVA and Student\'s t test with significance level of 5% was taken and held calculating relative risk and measures derived from it. Results: 198 women were evaluated (66 women in each group), the sociodemographic data, as well as, the level of physical activity were not associated with perception of pain after mammography, however, the exercise intervention led to lower perceived pain after the procedure, compared to groups 2 and 0. Conclusion: The physical warm-up exercises and stretching pre-examination were effective in decreasing pain perception and sensation among women who had the intervention of the upper limbs, however, observed also that women in to the legs also presented results from decreased perception of pain compared with the control group.
56

Determinação experimental dos perfis de espalhamento de tecidos mamários (normais e alterados) e sua potencialidade como ferramenta de diagnóstico / Experimental determination of scattering profiles from breast tissues (normal and altered) and its potentiality as a diagnostic tool.

Oliveira, Otávio Riani de 24 March 2006 (has links)
A distribuição angular de fótons espalhados (perfil de espalhamento) pode fornecer informações sobre as estruturas que compõe um tecido biológico, permitindo, a partir da análise desta, identificar a presença de anormalidades no tecido. A proposta deste trabalho foi desenvolver um procedimento experimental de medidas do perfil de espalhamento de tecidos mamários normais e alterados e, posteriormente, correlacionar as informações contidas neste com informações histopatológicas do tecido. Os perfis de espalhamento foram medidos no intervalo de momento transferido entre 0,2<= ? <=6,2 nm-1, utilizando um difractômetro Siemens D-5005, com ânodo de cobre e operando no modo reflexão. As amostras de tecidos mamários, foram previamente classificadas como tecidos normais, fibroadenomas e carcinomas. As intensidades medidas foram corrigidas por atenuação, efeitos geométricos e pela variação angular do feixe incidente. A eficácia do procedimento experimental foi validada através do uso de dados de referência para amostras de água. Os resultados mostraram que o perfil de espalhamento é uma característica única de cada tipo de tecido, sendo sua forma relacionada à morfologia microscópica do tecido. Na região em que x<=0,35 nm-1, verificou-se estatisticamente que as informações contidas nos perfis de espalhamento permitem a diferenciação entre tecidos normais e alterados. / Angular distribution of photons scattered by tissues (scattering profile) gives detailed information of structures within them and provides an alternative mean of distinguishing pathologies. The proposal of this work was to develop an experimental procedure to determine scattering profiles from breast tissues (normal and neoplastic) and to correlate the information contained in these profiles with histopathological information. The scattering profiles were measured in the interval of momentum transfer 0,2 ? ? ? 6,2 nm-1, using a powder diffractomer apparatus (Siemens D-5005), with copper anode and operation in reflection mode. The breast samples were previously histopathologically classified as normal tissues, fibroadenomes and carcinomas. The measured angular distribution was corrected by attenuation, geometric effect and the angular variation of the incident beam. The effectiveness of the experimental procedure was validated through the use of water reference data. The results shown that, scattering profile is unique impression of each type of tissue, being correlated with the microscopic morphological features. In the region where ? ? 0,35 nm-1, were statistically verified that the information contained in the scattering profiles allow the differentiation between normal and neoplastic breast tissues.
57

"Análise crítica e estimativa dos valores preditivos positivos das calcificações de aspecto mamográfico não benigno" / Critical analysis and estimative of predictive positive value of non benign mammographic aspect calcifications

Campos, Marilia Chaves Vieira de 18 July 2006 (has links)
Foram avaliados 507 casos de calcificações quanto as suas características (densidade, morfologia, distribuição, extensão e número) e associação com o câncer de mama.De acordo com os valores preditivos positivos de cada tipo de calcificação elas foram categorizadas pelo sistema BI-RADS em subcategorias 4A (2 a 10%), 4B (10,1 a 30%) e 4C (30,1 a 70,0%) e categoria 5 (acima de 70%). Todas as características se mostraram importantes na diferenciação das calcificações em benignas e malignas, em menor grau a densidade e em maior grau a morfologia e a distribuição. A distribuição linear ou segmentar, e a morfologia pleomorfa ou linear apresentaram as mais altas taxas de malignidade / Five hundred and seven cases of calcificações had been evaluated about its characteristics (density, morphology, distribution, extension and number) and association with the breast cancer. Using the VPP of each type of calcifications they had been categorized by the BI-RADS system in categories 4Â (2 to10%), 4B (10,1 to 30%) and 4C (30,1 to 70.0%) and category 5 (above 70%). All the characteristics had shown importance in the differentiation of the calcificações in benign and malignant, in lesser degree the density and bigger degree the morphology and distribuition. A linear or segmentary distribuition, and the pleomorfic or linear morphology had presented the highest taxes of malignidade
58

Estudo de indicadores de qualidade nas mulheres com câncer de mama  detectato pelo programa de rastreamento mamográfico do Hospital de Câncer de Barretos / Quality performance indicators in women with breast cancer detected by the mammographic screening program from Barretos Cancer Hospital

Tsunoda, Audrey Tieko 07 February 2012 (has links)
Os programas de rastreamento mamográfico (PRM) organizados atingem redução de mortalidade por câncer de mama em até 35%, principalmente quando submetidos a controle de qualidade efetivo. O PRM realizado pelo Hospital de Câncer de Barretos (HCB) é oferecido através de Unidades Móveis e Fixa desde 2003, para mulheres entre 40 e 69 anos, pertencentes à V Regional de Saúde do Estado de São Paulo Barretos (DRS). Trata-se de um projeto pioneiro no Brasil que necessita enquadrar-se em critérios de controle de qualidade para que atinja resultados comparáveis aos da literatura. Objetivo: Este estudo visa avaliar os indicadores de qualidade de detecção e tratamento das pacientes portadoras de câncer de mama diagnosticadas pelo PRM-HCB na DRS-V de São Paulo, entre 2003 e 2010. Métodos: Foram revisados os prontuários de todas as pacientes com câncer de mama, detectados pelo PRM-HCB no período. Os indicadores de controle de qualidade incluíram dados de: estadiamento, diagnóstico, tratamento, laudo patológico, intervalos de tempo, e dados descritivos. As pacientes sintomáticas tiveram os indicadores analisados em separado das assintomáticas. As variáveis contínuas e categóricas foram comparadas aos parâmetros estabelecidos pela European Breast Cancer Network (EBCN), utilizando-se o programa SPSS 15. Resultados: Foram incluídas 257 mulheres. Os estádios clínicos 0 e I compreenderam 68,3% (125/183) dentre as assintomáticas e 33,8% (24/71) das sintomáticas, com 3 casos sem informação (nível desejável >70%). O tamanho médio do tumor foi de 1,96cm entre as assintomáticas e de 3,2cm dentre as sintomáticas (p=0,000). A cirurgia foi conservadora em 85,2% das assintomáticas e em 62,5% das sintomáticas. Dentre os 25 indicadores adequadamente avaliados, 18 encontravam-se em níveis desejáveis, sendo 7 deles a respeito da adequação do tratamento cirúrgico. Um dos indicadores de tempo esteve em nível aceitável (tempo entre a indicação de cirurgia e o procedimento cirúrgico médio de 17,9 dias úteis, nível aceitável = 15du), enquanto outros 2 estiveram insuficientes. Os intervalos de tempo para o laudo anátomo-patológico (AP) estiveram em níveis satisfatórios (82,1% dos laudos AP de diagnóstico em 10du ou menos, nível desejável 80%). As principais deficiências relacionadas ao tempo foram da mamografia de rastreamento até a matrícula (média de 32du, nível aceitável = 5du) e da matrícula aos demais exames diagnósticos (média de 27du; nível aceitável = 5du). Conclusões: Os indicadores de estádio dentre as mulheres assintomáticas estiveram em níveis aceitáveis, entretanto, as mulheres sintomáticas apresentaram tumores maiores e em estádios mais avançados. A abordagem multidisciplinar como Unidade de Mama possibilitou atingir níveis adequados e comparáveis aos europeus quanto aos métodos diagnósticos e terapêuticos. Deficiências quanto aos intervalos de tempo e barreiras que dificultam a adesão da população demandam intervenções futuras. A análise de indicadores de qualidade foi factível e permitiu diagnosticar uma adequação parcial dos processos de diagnóstico e tratamento das pacientes com câncer de mama detectado pelo PRM-HCB, segundo os critérios estabelecidos pela EBCN / In order to achieve a reduction of 35% in breast cancer mortality, organized mammographic screening (MMGS) programs demand quality assurance. BCH has been offering MMGS for 40 to 69-year-old women, since 2003, by means of three mobile units and a standardized breast unit, through the public health system. It is a pioneer Brazilian project, in a São Paulo State nonmetropolitan setting, that has to attend quality assurance to achieve results comparable to those presented in the actual literature. Objective: This study aims to analyze the quality performance indicators regarding diagnosis methods and treatment offered to women whose breast cancer was detected by the BCH MMGS program, between 2003 and 2010. Methods: We reviewed the medical records of breast cancer patients whose disease was detected by the BCH MMGS program during the period. Quality indicators included data about: stage, diagnosis, treatment, pathology, time intervals, and descriptive information. Symptomatic women at the moment of the first evaluation had their data evaluated separately from the asymptomatic. The data gathered were analyzed using SPSS 15. The results were compared to the European Breast Cancer Network Guidelines for quality assurance. Results: 257 patients were included in this study. Stages 0 and I corresponded to 68.3% (125/183) of the asymptomatic cases, and 33.8% (24/71) of the symptomatic group (desirable level >70%), with 3 missing cases. The mean tumor size was 1.96cm for the asymptomatic patients, and 3.2cm for the symptomatic (p=0.000). Breast conserving surgery was possible in 85.2% of the asymptomatic patients, and in 62.5% of the symptomatic. Among the 25 quality indicators adequately evaluated, 18 were in desirable levels. Seven of them were related to the surgical approach. One of the time interval indicators was considered acceptable (mean time interval between decision to operate and date of surgery = 17.9 working days, acceptable level = 15wd), but 2 were in insufficient levels. Time intervals for pathology reports were sufficient (82.1% of the diagnostic pathology reports were performed in 10wd or less, desirable level80%). Main deficiencies were related to time interval between the mammogram and the first evaluation (mean=32wd, acceptable level=5wd) and the evaluation and the results of the additional exams (mean=27wd, acceptable level=5wd). Conclusions: Stage quality indicators were adequate for the asymptomatic group. Symptomatic women had larger tumors, with more advanced stages. The multidisciplinary approach was important to achieve acceptable and desirable levels regarding diagnostic methods and treatment. Deficiencies concerning time intervals and possible barriers that represent delays demand a future action plan. The analysis of quality indicators was feasible and allowed to diagnose a partial adjustment in the diagnostic and treatment process of the cancer patients detected by the BCH MMGS based on the EBCN Guidelines criteria
59

O impacto da integração do esquema CAD como ferramenta auxiliar na mamografia / The impact of integration of CAD scheme as auxiliary tool in mammography

Verçosa, Luciana Buffa 07 April 2014 (has links)
O câncer de mama é uma triste realidade no contexto mundial, sendo o segundo tipo mais frequente entre as mulheres, representando um grave problema de saúde pública. Para diagnosticá-lo, realiza-se a mamografia, interpretada por médicos radiologistas devidamente treinados. Porém, diferentes fatores dificultam a interpretação da imagem mamográfica, como a fadiga visual, stress e distração do profissional, podendo ocasionar falhas ou atraso no diagnóstico. É possível minimizar a taxa de erros se a análise for realizada por meio da dupla leitura, realizada por dois radiologistas ou auxiliada por esquemas computacionais (CAD), no intuito de funcionar como uma segunda opinião. O objetivo do presente estudo foi avaliar a influência do CAD na interpretação de imagens mamográficas de radiologistas experientes, tanto como ferramenta auxiliar na detecção de nódulos e de agrupamentos de calcificações (CADe) quanto como classificador de nódulos (CADx). Os resultados obtidos mostraram que o CAD influenciou positivamente na precisão diagnóstica quando utilizado como classificador, aumentando a sensibilidade e a especificidade dos radiologistas, com a vantagem de não aumentar significativamente a taxa de falsos positivos. Tal fato demonstra que o CAD auxiliou no diagnóstico, sendo ferramenta plausível de ser utilizada na análise mamográfica. Mais estudos devem ser realizados seguindo esta metodologia a fim de realizar novos testes com maior número das amostras e de analisadores. Futuros estudos poderiam explorar especificamente a atuação dos esquemas CADx quando aplicados exclusivamente na análise de mamas densas, em que os sinais radiológicos não são tão evidentes, o que é um grande entrave para diagnósticos corretos. / Breast cancer is a sad reality all over the world, the second most frequent type among women, therefore a serious public health concern. For it diagnosis, mammography is performed and interpreted by qualified medical radiologists. However, several factors have limited the correct interpretation of mammographic images, as visual fatigue, stress and professional distraction, which may result in failed or delayed diagnosis. Its possible to minimize the error rate performing the analysis by means of double reading or by the support of computational schemes (CAD) in order to act as a second opinion. The aim of this study was evaluate the impact of CAD on the interpretation of mammographic images performed by experienced radiologists, aiming to detect nodules and clusters of calcifications (CADe) and as classifier nodules tool (CADx). The results showed that CAD has positively influenced the diagnostic accuracy when used as a classifier, increasing the sensitivity and specificity of radiologists with the advantage of not significantly increasing the rate of false positives. This shows that the CAD really improved the diagnosis, being a useful tool in the analysis of mammographic images.. Additional tests including more samples and analyzers should be performed according to this approach. Future studies could specifically explore the performance of CADx schemes when applied exclusively to the analysis of dense breasts, where the radiological signs are not so obvious, which is a serious difficulty for the medical examination.
60

Interface e integração de esquemas de processamento de imagens para avaliação automática de mamogramas digitalizados / Interface and Integration of Images Processing Schemes for Automatic Evaluation of Digitized Mammograms

Lagoeiro, Fábio Gomes 13 December 2004 (has links)
Nos últimos anos, a avaliação automática de mamogramas digitalizados tem sido muito estudada. Através da integração de pacotes de programas semi-automáticos de pré-processamento e processamento para auxílio ao diagnóstico precoce do câncer de mama, foi desenvolvido um esquema CAD (Computer-Aided Diagnosis) para mamografia, com o objetivo de otimizar o tempo de processamento da região de interesse e automatizar os processos sem a necessidade de intervenção do usuário durante a execução. Com a automatização criou-se uma interface de fácil operação. Os pacotes de processamento foram devidamente documentados, tornando-se um esquema estruturado / In the last years, the automatic evaluation of digitized mammograms has been a lot studied. Through the interconnection of packages of semiautomatic of pre-processing and processing for aid to the precocious diagnosis of the breast cancer, a Computer-Aided Diagnosis (CAD) schemes for mammography was developed, with the objective to optimize the time of processing of the interest region and to automate the processes without necessity of intervention of the user during the execution. With automation an interface of easy operation was created. The processing packages were documented becoming a structured scheme