• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 107
  • 101
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 243
  • 81
  • 64
  • 59
  • 53
  • 45
  • 41
  • 35
  • 34
  • 29
  • 25
  • 24
  • 21
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Medical treatment of chronic non-infectious osteomyelitis in the jaws. A systematic review

Sebrén, Åsa, Nelson, Helena January 2018 (has links)
Syfte: Att systematiskt sammanfatta litteraturen inom området för medicinska behandlingsalternativ för icke-infektiös, kronisk osteomyelit i käkarna, utvärderat genom utläkning i ben och smärtlindring. Metod: En systematisk litteraturöversikt gjordes i fyra databaser; PubMed, Cochrane Library, Web of Science och Scopus. Översikten utfördes enligt instruktioner från ”PRISMA checklist” och ”CRD’s guidance”. En kvalitetsbedömning gjordes av samtliga inkluderade publikationer.Resultat: Sökningen resulterade i 2 100 artiklar. Efter urvalsprocessen återstod tre artiklar som inkluderades i denna systematiska litteraturöversikt. Samtliga studier utvärderade olika typer av bisfosfonatbehandlingar – ibandronat, pamidronat och disodium clodronat. Den smärtlindrande effekten utvärderades i alla tre studierna och utläkningen av benet utvärderades i två av artiklarna. Konklusion: Behandling av icke-infektiös osteomyelit med bisfosfonater visar en reduktion av smärta. Dock är den smärtlindrande effekten beroende på typen av bisfosfonat. Resultaten gällande utläkningen av ben är tvetydiga och därför kan ingen konklusion gällande detta göras. Endast en artikel ansågs i kvalitetsgranskningen ha hög kvalitet. För att kunna ta fram tydliga, evidensbaserade riktlinjer gällande behandling av icke-infektiös osteomyelit behövs fler kliniska studier som håller hög kvalitet. Bisfosfonater verkar vara ett bra behandlingsalternativ av icke-infektiös osteomyelit. Ett alternativ till bisfosfonater, skulle kunna vara behandling med denosumab, som har liknande verkningsmekanism men kortare halveringstid. Dock krävs fortsatta studier inom detta område. / Aim: To systematically review the literature of medical treatment alternatives of non-infectious chronic osteomyelitis in the jaws regarding bone healing and pain relief. Methods: A systematic literature search has been made in four databases; PubMed, Cochrane Library, Web of Science and Scopus. The review was performed with directions from the PRISMA checklist and CRD’s guidance. A quality assessment was made of the included studies.Results: The search resulted in 2 100 articles and after the selection process, only three articles were included in this review. The studies evaluated different types of bisphosphonates - ibandronate, pamidronate and disodium clodronate. The reduction of pain was evaluated in all three articles and the bone healing was assessed in two of the articles. Conclusion: Treatment of non-infectious osteomyelitis with bisphosphonates shows a reduction in pain. However, the pain-relieving effect is most probably dependent on the type of bisphosphonates. The results of bone healing assessed from Tc-scans are ambiguous and therefore no conclusion can be made. Only one article in this review was considered to have high quality in the quality assessment. To enable clear guidelines regarding treatment of non-infectious osteomyelitis, more clinical trials with high quality is desirable. In summary, bisphosphonates seem to be a good alternative in treatment of non-infectious osteomyelitis. An alternative to bisphosphonates might be treatment with denosumab, which have a similar mechanism of action but shorter half-life. However, further research is needed.
112

Superficial temporal artery flap: its development and application in the dog and cat

Fahie, Maria Aline 17 December 2008 (has links)
Cutaneous arterial blood supply to the temporal region was evaluated in 8 dogs and 8 cats. Dissection of 4 dog and 4 cat cadavers revealed the location of cutaneous branches of the superficial telnporaJ artery supplying the frontalis tnuscle and skin of the temporal region. The frontalis 1l1uscle is a thin muscle dorsal to the temporaJis muscle that extends cranially and rostral1y from the rostral border of the scutulU111 to the forehead and upper eyelid. Microangiography and subtraction radiography of the external carotid and superficial telnporal arteries were used in 4 dogs and 4 cats to determine arterial blood supply to the temporal region and frontalis muscle. A superficial temporal artery (ST A) flap was developed in 9 dogs [ group A (n=5), group B (n=4)]. Ligation of the superficial tetnporal artery in the control dogs (n=5), rendered flaps dependent on the subdermal plexus. Dogs in group A (n=5) and the control group (n=5) had flap lengths that extended to the contralateral eye, while group B (n=4) flaps extended to the contralateral zygomatic arch. A11 flap widths were equivalent to the width of the zygomatic arch in the individual dog. Mean length of surviving tissue (mean survival length) (+/- SD) of control flaps was 7.0 (0.6) ern, compared with experimental flaps, group A 9.) (0.8) em and group B 10.4 0.1) cm. Mean survival percentage area of control flaps was 73.5 (7.4) %, compared with experimental flaps, group A 93.1 (7.5) 0/0 and group B 69.1 (4.5) 0/0. The mean survival length of control and experimental flaps was significantly different (P < 0.05). There was no significant difference between survival lengths of the experimental groups. / Master of Science
113

Analyses of Effects of Pigments on Maxillofacial Prosthetic Material

Hu, Xingxue 01 September 2010 (has links)
No description available.
114

Développement, modélisation et caractérisation d'une maille innovante réalisée en fabrication additive pour les grands défauts osseux / Conception, modelisation and simulation of a 3D printed bone substitute for maxillofacial surgery

Adam, Jérémy 13 December 2017 (has links)
Ce travail de thèse traite du développement d’une maille en titane imprimée en 3D pour le comblement des grands défauts osseux. La perte de substance osseuse intervient lors de traumatismes importants ou de chirurgies ablatives (dues à des infections ou à des cancers). Lorsque le défaut atteint un stade critique, la régénération osseuse est impossible et on assiste à une perte de fonction. Il faut alors recourir à des chirurgies reconstructrices comme par exemple la reconstruction mandibulaire. Aujourd’hui, la chirurgie communément pratiquée pour reconstruire la mandibule est la reconstruction par lambeaux libres de fibula, laquelle demande un investissement en temps et en ressource colossale pour des résultats mitigés avoisinant les 10% de taux d’échec. En nous basant sur la littérature internationale, nous avons développé une maille en titane imprimée en 3D pour remplacer l’autogreffe de fibula et ainsi limiter les effets secondaires liés au site donneur tout en offrant aux cellules mésenchymateuses des conditions optimales à la colonisation osseuse. D’un point de vue mécanique, cela consiste à abaisser la rigidité native du titane (110GPa) à une rigidité comprise entre 0,1 et 1 GPa. Pour réaliser cette maille, nous avons mis en place une méthodologie de design qui nous a permis d’innover en mettant au point un système de reprise de charge. Ce système de reprise de charge permet d’adapter la réponse de l’implant en fonction de l’intensité de la sollicitation, ce qui permet de combiner une rigidité faible et une résistance à l’effort élevée. Les différentes itérations de design ont été testées par éléments finis, jusqu’au motif final, lequel a été caractérisée lors de tests mécaniques réels en compression, en traction et en flexion. Remplissant la majorité du cahier des charges, nous avons ensuite mis au point une étude animale, laquelle sera réalisée ultérieurement. Enfin, cette étude a permis de mettre en évidence certaines limitations de l’impression 3D métallique, principalement liés aux surfaces non supportées que nécessitent la reprise de charge. Cette maille très prometteuse est aujourd’hui en cours d’optimisation pour permettre d’être rapidement mise à la disposition des patients. / The work detailed in this thesis is about a titanium 3D printed mesh for large bone defects. Large bone defects are often due to surgical resections, performed after a cancer or an infection. When the defect reach a critical size, bone regeneration is impossible and it often leads to the loss of function. When it happened, the wound need to be cured using reconstructive surgery. The mandibular reconstruction is one of the most performed reconstructive surgery. Nowadays, we reconstruct the mandible with the fibula free flap technique, which require huge amount of time and resources for mixed results (around 10% failure rate). Based on the international literature, we developed a titanium 3D printed mesh to replace the fibula autograft and limit its side effect while offering to mesenchymal cells optimal growing environment. On the mechanical point of view, this environment requires to decrease the titanium initial rigidity from 110GPa to a range between 0.1 and 1GPa. In order to achieve that goal, we have developed a design methodology that lead us to innovation. We developed a load restauration system that allow us to combine low rigidity and high resistance. In order to find the final design, we used finite element modeling. Then, the final design have been tested mechanically in compression, traction and flexion. Because most of the requirements were reached, we designed an animal study which should take place in the next years. Eventually, we discovered some limitation for metallic 3D printing, essentially due to unsupported areas required for the load restauration. This innovative mesh is today optimized in order to be rapidly given to patients in the need.
115

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Pinheiro, Juliana Barchelli 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
116

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Cobein, Marcus Vinicius 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
117

Análise fotoelástica das cargas aplicadas em próteses parciais removíveis nas grandes perdas de maxila / Photoelastic analysis of the loads applied to removable partial dentures in large ressections of maxilla

Carvalho, Giorgia Borges de 12 December 2012 (has links)
Este trabalho teve a finalidade de avaliar pela técnica fotoelástica, o efeito que a prótese parcial removível teria, em aliviar as tensões sobre as raízes dos dentes. Para tanto preparamos um modelo com três tipos de desenhos de próteses parciais removíveis, simulando uma reabilitação nas grandes perdas de maxila. Todos os modelos de desenhos apresentaram planos guias em incisivo central e segundo molar, e se diferenciaram da seguinte forma: modelo 01, grampo circunferencial simples em canino, grampo gêmeo entre primeiro e segundo pré-molar e grampo gêmeo entre primeiro e segundo molar; modelo 02, utilizamos os mesmos grampos colocados no modelo 01 incluindo neste modelo um recobrimento palatino, modelo 03, grampo gêmeo entre canino e primeiro pré-molar, grampo gêmeo entre segundo pré-molar e primeiro molar e grampo circunferencial simples em mesial de segundo molar. Foram aplicadas cargas verticais de 10 kg, 15 kg e 20 kg em canino, segundo pré-molar e primeiro molar. Os resultados permitiram concluir que: Os planos guia comprovaram sua efetividade através do contato pleno nos dentes preparados para o seu assentamento. O recobrimento palatino não amenizou as cargas nas raízes dos dentes. Os grampos gêmeos, colocados em uma posição mais anterior, indicam uma distribuição melhor das tensões. Os grampos circunferenciais simples, colocados mais posteriormente, indicam uma melhor distribuição das tensões. Os modelos 01 e 02 apresentaram maiores tensões em incisivo central comparados com o modelo 03. O modelo 03 foi o que melhor distribuiu as cargas de forma mais equilibrada mostrando tensões de menor magnitude. Os melhores modelos de próteses parciais removíveis, pela perspectiva de transferência de tensão foram primeiramente o modelo 03, depois o modelo 01 e por fim o modelo 02. A mudança do desenho da PPR alterou a distribuição das tensões nos dentes dos modelos avaliados. / This study aimed to evaluate by the photoelastic technique, the effect that the partial denture would have to reduce tensions on the roots of teeth. For this reason, was prepared a model with three types of removable partial dentures designs, simulating rehabilitations in large ressections of maxilla. All models presents guide-planes on central incisor and second molar, and was differentiated as follows: Model 01, simple circumferential clasp in canine, twin clasps between first and second premolar and twin clasps between first and second molar; model 02, we use the same clasps as model 01 only including a palatal covering in this model, model 03, twin clasps between canine and first premolar, twin clasps between second premolar and first molar and simple circumferential clasp at mesial of second molar. Were applied vertical loads of 10 kg, 15 kg and 20 kg in canine, second premolar and first molar. The results showed that: The guide-planes proved its effectiveness through full contact in the teeth prepared for their settlement. The palatal covering failed to alleviate the stress on the roots of teeth. Twins clasps, placed in a more anterior position, indicating a better distribution of stresses. Simple circunferencial clasp, placed in a more posterior position indicating a better distribution of stresses. Models 01 and 02 had higher tensions in central incisor compared with the model 03. The Model 03 was the best considering equilibrated load distribution showing stress of lesser magnitude. The best models of removable partial dentures, from the perspective of stress transfer were first model 03, followed by the model 01 and then finally the model 02. The change os design of RPD changed the distributions os tensions in teeth of evaluated models.
118

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Juliana Barchelli Pinheiro 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
119

Identificação da microbiota de próteses bucomaxilofaciais e tecidos adjacentes e avaliação da efetividade antimicrobiana de diferentes protocolos de higiene e de seus efeitos sobre propriedades de dois silicones / Identification of the microbiota of maxillofacial prostheses and adjacent tissues and evaluation of the antimicrobial effectiveness of different hygiene protocols and their effects on properties of two silicones

Pinheiro, Juliana Barchelli 06 November 2015 (has links)
O objetivo do presente estudo foi identificar, clinicamente, os micro-organismos presentes em próteses e tecidos adjacentes, avaliar laboratorialmente a ação antimicrobiana de diferentes protocolos de higiene sobre os principais micro-organismos identificados e, ainda, avaliar a influência dos protocolos de higiene na alteração de cor, dureza Shore A, rugosidade superficial e absorção de líquidos, de um novo silicone (Bio-Skin), em comparação ao MDX 4-4210. Para identificação dos micro-organismos, 43 indivíduos portadores de próteses maxilofaciais foram submetidos à colheita do biofilme na região da prótese e tecidos adjacentes e 38 espécies alvos de micro-organismos foram pesquisadas por meio do método de hibridação de DNA Checkerboard. A análise da ação antimicrobiana foi conduzida por meio da formação de biofilmes específicos de 6 espécies selecionadas. 288 espécimes pigmentados com pó de maquiagem foram confeccionados com cada material, e distribuídos em grupos para imersão em gluconato de clorexidina a 0,12%, Ricinus communis a 10%, e escovação com sabão neutro. Como controle, um grupo foi imerso em água. Para análise da influência dos protocolos de higienização nas propriedades dos silicones, 120 corpos de prova circulares de cada material foram confeccionados (n=10): sem pigmentação (GC: controle), com pó de maquiagem (GP), opacificador (GO) ou opacificador + pó de maquiagem (GPO), para então serem submetidos à higienização: EA (imersão em água destilada + escovação com sabão neutro controle), ERc10% (imersão em solução de Ricinus communis 10% + escovação com sabão neutro) e ECl0,12% (imersão em gluconato de clorexidina 0,12% + escovação com sabão neutro). O período de higienização simulou um ano de uso clínico. As variáveis de resposta quantitativas foram mensuradas imediatamente após a obtenção dos espécimes e após a aplicação dos protocolos de higiene e a variação obtida foi utilizada na análise estatística. Para análise da ação antimicrobiana dos protocolos de higiene e para alteração de cor, dureza Shore A e rugosidade superficial, realizou-se Análise de variância e Teste Complementar de Tukey para comparação das médias. Para a absorção de líquidos, aplicou-se o Teste de Kruskal-Wallis. Para comparação da contagem de micro-organismos presentes nas próteses e tecidos adjacentes empregou-se o Teste de Wilcoxon (Signed-rank Test). Para análise dos dados obtidos pela contagem de UFC, para análise da ação antimicrobiana dos protocolos de higiene, empregou-se Two-way ANOVA e Teste Complementar de Tukey. Todas as análises foram conduzidas com nível de significância 5%. O método de hibridação de DNA Checkerboard indicou a presença das 38 espécies nas próteses e tecidos adjacentes e foram selecionados os seguintes micro-organismos: C. glabrata, S. aureus, S. mutans, E. coli, E. faecalis e P. aeruginosa. Para a análise antimicrobiana, o gluconato de clorexidina a 0,12% foi o mais eficaz, seguido pela escovação mecânica, contra as 6 espécies. A alteração de cor não foi influenciada pelos protocolos de higiene e a menor alteração foi encontrada com o silicone Bio-Skin dos grupos GP e GPO. O silicone MDX apresentou menor variação de dureza Shore A em função do protocolo de higiene ECl0,12%, enquanto a dureza do Bio-Skin não foi influenciada pelos protocolos de higiene. A variação da dureza entre os dois silicones foi diferente somente quando submetidos ao protocolo ERc10%. Para a rugosidade superficial, o silicone MDX apresentou a menor variação de rugosidade. A porcentagem de absorção de líquidos do silicone MDX 4-4210 não foi influenciada pela pigmentação ou protocolos de higienização. Para o Bio-Skin, a porcentagem de absorção foi maior nos grupos GC e GO quando submetidos ao protocolo EA. Nota-se que houve uma interação entre pigmento e protocolo de higiene, onde para o silicone MDX, a absorção foi maior quando submetidos ao protocolo ECl0,12% e para o Bio-Skin, houve uma maior porcentagem de absorção nos grupo GC e GO associados à escovação e imersão em água e nos grupos GP e GPO associado ao protocolo ECl0,12%. Conclui-se que tanto as próteses quanto os tecidos adjacentes apresentam grande quantidade de micro-organismos colonizadores e que cuidados diários de higiene são essenciais. Os protocolos de imersão em gluconato de clorexidina a 0,12% e de escovação mecânica com sabão neutro possuem efetividade antimicrobiana sobre os principais micro-organismos comumente presentes em próteses e tecidos e o silicone MDX 4-4210 apresentou menor contagem de UFC quando comparado ao Bio-Skin. Ambos os materiais apresentaram variações em função das diferentes pigmentações e protocolos de higiene, entretanto, as mesmas foram discretas e dentro de padrões clínicos aceitáveis. As menores alterações foram observadas quando os materiais foram expostos aos protocolos de imersão em gluconato de clorexidina a 0,12% e escovação com sabão neutro. / The aim of this study was to identify clinically the microorganisms present in prostheses and adjacent tissues, evaluated laboratory antimicrobial action of different hygiene protocols on the main identified microorganisms and also evaluate the influence of hygiene protocols in color change, Shore A hardness, surface roughness and absorption of liquids, a new silicon (Bio-Skin) compared to the MDX 4-4210. For identification of microorganisms, 43 individuals with maxillofacial prostheses were submitted to harvesting the biofilm on the prosthesis and adjacent tissues and 38 targets species were surveyed through the Checkerboard DNA-DNA Hybridization method. The analysis of antimicrobial activity was conducted by formation of specific biofilm in six selected species. 288 specimens with pigmented makeup powder were fabricated with each material, and divided into groups for immersion in 0.12% chlorhexidine gluconate, Ricinus communis 10%, and brushing with neutral soap. As a control, one group was immersed in water. To analyze the influence of hygiene protocols on the properties of silicones, 120 circular specimens of each material were prepared (n = 10): no pigmentation (CG: control), with makeup powder (GP), opacifier (GO) or opacifier + makeup powder (GPO), and then be submitted to cleaning: EA (immersion in distilled + brushing water with mild soap - control), ERc10% (immersion in Ricinus solution communis 10% + brushing with mild soap) and ECl0 12% (immersion in chlorhexidine gluconate 0.12% + brushing with neutral soap). The hygiene period simulated one year of clinical use. The quantitative response variables were measured immediately after obtaining the specimens and after the application of hygiene protocols and the variation obtained was used in the statistical analysis. For analysis of antimicrobial hygiene protocols and color change, Shore A hardness and surface roughness, there was analysis of variance and Tukey Supplementary test for comparison of averages. For the absorbing liquid, we applied the Kruskal-Wallis test. For comparing the count microorganisms present in prostheses and adjacents tissues we used the Wilcoxon test (Signed-rank Test). To analyze the data obtained by CFU counts for analysis of antimicrobial hygiene protocols, we used two-way ANOVA and Tukey Complementary Test. All analyzes were conducted with significance level of 5%. The method of Checkerboard DNA-DNA Hybridization indicated the presence of 38 species in the prosthesis and adjacent tissue and the following microorganisms were selected: C. glabrata, S. aureus, S. mutans, E. coli, E. faecalis and P. aeruginosa. For antimicrobial analysis, 0.12% chlorhexidine gluconate was the most effective, followed by mechanical brushing, against six species. The color change was not influenced by hygiene protocols and the slightest change was found with the Bio-Skin silicone GP and GPO groups. Silicone MDX showed less variation in Shore A hardness according to the maintenance protocol ECl0,12%, while the hardness of Bio-Skin was not influenced by hygiene protocols. The variation in hardness between the two silicones were different only when subjected to ERc10% protocol. To the surface roughness, the MDX silicone showed the smallest variation of roughness. The percentage of absorption for the MDX 4-4210 silicone was not influenced by the pigment and sanitization protocols. For the Bio-Skin, the percentage of absorption was higher in GC and GO groups when subjected to EA protocol. Note that there was an interaction between pigment and maintenance protocol, where for silicone MDX, absorption was greater when subjected to ECl0,12% protocol and Bio-Skin, there was a greater percentage absorption in the GC group and GO associated with brushing and immersion in water and GP groups and GPO associated with ECl0,12% protocol. It was concluded that both prosthesis as adjacent tissues exhibit great amount of microoorganisms colonizing and that daily hygiene are essential. The immersion in chlorhexidine gluconate 0.12% and mechanical brushing protocols with neutral soap have antimicrobial activity on the main microorganisms commonly present in prosthetics and tissue and silicone MDX 4-4210 had lower CFU counts compared to Bio Skin. Both materials showed variations due to different pigmentations and hygiene protocols, however, they were discreet and within acceptable clinical standards. Minor changes were observed when the materials were exposed to immersion protocols chlorhexidine gluconate 0.12% and brushing with neutral soap.
120

Efeito sobre o reparo ósseo de campo magnético sepultado em crânio de ratos após reconstrução com osso autógeno, hidroxiapatita sintética e cartilagem alógena

Abreu, Maíra Cavallet de January 2012 (has links)
A compreensão dos fenômenos de reparo ósseo representa parte fundamental da odontologia e da cirurgia bucomaxilofacial. Objetivo: O presente trabalho tem como objetivo avaliar a influência da estimulação de campo magnético sepultado sobre o reparo ósseo em calvária de ratos após reconstrução com enxerto ósseo autógeno, implante de hidroxiapatita granulada sintética ou enxerto alógeno de cartilagem, comparados entre si e aos controles sem estimulação magnética. Materiais e métodos: foram utilizados 95 ratos Wistar machos, divididos em grupos constituidos por 5 animais. Foram realizados defeitos ósseos críticos na calvária dos animais, sendo os mesmos imediatamente reconstruídos, isoladamente com, enxerto ósseo autógeno, hidroxiapatita granulada sintética e enxerto alógeno de cartilagem, sob influência ou não de campos magnéticos sepultados. Foram realizadas avaliações aos 15, 30 e 60 dias pós-operatórios. Apenas um grupo não sofreu intervenção cirúrgica (Naive), para fornecer os dados para obtenção da atividade fisiológica das enzimas fosfatase alcalina e fosfatase ácida. Em todos os tempos experimentais foi realizada a quantificação da neoformação óssea por meio da histomorfometria. A avaliação da intensidade de expressão da proteína osteopontina, foi obtida somente aos 60 dias Resultados: a avaliação histomorfométrica evidenciou interação significativa entre grupos e tempos com p=0,008. Aos 60 dias, nos animais que receberam reconstrução com osso autógeno o grupo sob influência do campo magnético apresentou percentual de preenchimento ósseo superior ao grupo sem influência do estímulo magnético. A mensuração da atividade das enzimas fosfatase alcalina e fosfatase ácida evidenciou interação significativa entre grupos e tempos com p=0,02 e p=0,005 respectivamente. Aos 60 dias, todos os grupos apresentaram atividade de ambas enzimas significativamente inferior ao grupo Naive. A análise imunoistoquímica realizada não evidenciou diferença significativa na expressão da enzima osteopontina com a metodologia empregada. Conclusão: o presente trabalho contribuiu para o entendimento da influência do campo magnético sepultado sobre o reparo ósseo em crânio de rato. A partir dos resultados encontrados, novas metodologias podem ser propostas para complementar os resultados obtidos e fortalecer a presente linha de pesquisa. / Objective: the comprehension of the phenomenon of bone repair represents a fundamental part of dentistry and of oral and maxillofacial surgery. The present work has as its objective, to evaluate the influence of a stimulated magnetic field implanted on the calvarial bone of rats after its reconstruction with autogeneous bone graft, synthetic hydroxyapatite crystals or with the insertion of allogeneic cartilage, in comparison to no magnetic stimulation. Materials e methods: 95 Wistar male rats were used, divided into groups with 5 animals in each. The autogeneous bone graft, the synthetic hydroxyapatite crystals and the insertion of allogeneic cartilage were each used separately in the performed interventions of reconstruction with or without the influence of implanted magnetic fields. Evaluations were performed in 15, 30 and 60 days after surgery. Only one group did not suffer surgical intervention (Naïve); this group provided data for the physiological activity of the alkaline and acid phosphatase enzymes. Also, quantification of bone neoformation was obtained through histomorphometry in all experimental time periods, and evaluation of the osteopontin protein expression of intensity in 60 days. Results: the histomorphometry 60-day evaluation, showed evidence of a significant interaction between the groups and the time of p=0,008 on the animals that received reconstruction with autogeneous bone. The group that was influenced by the magnetic field presented a percent of bone reconstruction superior to that of the group which did not receive magnetic stimulation. In 60 days, activity mensuration of the alkaline and acid phosphatase enzymes, showed evidence of significant interaction between the groups and the times of p=0,02 and p=0,005, respectively. In all groups, activity of both enzymes was present and significantly inferior to the Naive group. The immunohistochemistry analysis performed did not show evidence of any significant difference in the oseopontin enzyme expression with the applied methodology. Conclusion: this work contributed to the understanding of the influence that an implanted magnetic field has on bone reconstruction. From the results found, new methodologies can be proposed as a complementary to obtained results and can strengthen the present line of research.

Page generated in 0.0505 seconds