Spelling suggestions: "subject:"medição"" "subject:"edição""
431 |
Um sistema de identificação de fontes de ruído utilizando a técnica de beamformingSilva, Yuri Adson Ribeiro January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-24T06:24:05Z (GMT). No. of bitstreams: 1
263935.pdf: 10133426 bytes, checksum: 7cbcb4f5cbc79418e56fced5bd3647a1 (MD5) / This work describes the development and the application of an acoustical measurement system for identification of noise sources. Currently known techniques are able to map the noise radiation from a specific region in space using the sound field measured by a fixed array of microphones. The developed system uses a 32-microphones planar array processed by a classical frequency domain Beamforming algorithm. Different array geometries were studied using computational simulation and finally a multi-arm spiral array was designed based on the results from the simulations. To overcome some limitations of the available commercial systems, which are typically expensive and present a lot of operational constraints, low cost microphones and a flexible and portable signal acquisition platform were used. The microphones were designed and built using a commercially available electret cartridge coupled with a simple circuitry for the signal conditioning, making the easily integration with the acquisition system. Experiments on the microphones response characteristics allowed to select the most adequate samples, considering an expected operational range of 15 kHz.
To validate the system, experiments were carried out in an anechoic chamber and it showed good agreement between the theoretical and experimental results. Finally, two different cases from the automotive industry were used to test the application of the system for the purpose of noise source identification. First, the sound transmission through a complex automotive structure with acoustic treatment was evaluated, showing clearly the regions of sound leakage, particularly at high frequencies. In a second experiment the radiated noise out of the engine compartment from a vehicle operating at a dynamometer was mapped. In this case the system was capable of presenting good results using the cross spectrum matrix diagonal removal technique, enabling the identification of the major noise sources.
|
432 |
Efeitos da terapia cognitivo-comportamental na responsividade nociceptiva de mulheres com fibromialgiaChakr, Rafael Mendonça da Silva January 2011 (has links)
OBJETIVOS: Estudar os efeitos da terapia cognitivo-comportamental administrada em seis entrevistas semanais consecutivas sobre responsividade à dor na fibromialgia. MÉTODOS: Mulheres portadoras de fibromialgia (n=32) foram randomizadas para receber terapia cognitivo-comportamental por 6 semanas ou tratamento usual. Avaliação dos desfechos foi feita no início do estudo e, também, em 6 e 12 semanas. RESULTADOS: Nas primeiras 6 semanas, o limiar do reflexo nociceptivo aumentou no grupo que recebeu terapia cognitivo-comportamental e diminuiu no grupo recebendo tratamento usual (média ± DP, 4,4 ± 13,7mA vs. -10,2 ± 9,9mA; P=0,005). Esta diferença também foi demonstrada na 12ª semana (média ± DP, 7,3 ± 9,2mA para terapia cognitivo-comportamental vs. -5,4 ± 13,5mA para tratamento usual; P=0,01). CONCLUSÃO: A terapia cognitivo-comportamental aumenta o limiar nociceptivo de mulheres com fibromialgia medido através do reflexo nociceptivo de flexão. / OBJECTIVES: To study the effects of cognitive-behavioral therapy administered in six weekly consecutive interviews on fibromyalgia pain responsiveness. METHODS: Fibromyalgia women (n=32) were randomized to either six weeks of cognitive-behavioral therapy or usual care. Outcome measures were assessed at baseline and weeks 6 and 12 visits. RESULTS: After six weeks of follow-up, nociceptive flexion reflex threshold was higher in cognitive-behavioral treatment group, and lower in usual care group (mean ± SD, 4,4 ± 13,7mA vs. -10,2 ± 9,9mA; P=0,005). This difference was also seen at week 12 (mean ± SD, 7,3 ± 9,2mA vs. -5,4 ± 13,5mA, in cognitive-behavioral therapy and usual care groups, respectively; P=0,01). CONCLUSION: Cognitive-behavioral therapy increases nociceptive flexion reflex threshold among women with fibromyalgia.
|
433 |
Sistema de aquisição do ciclo pressão-volume cardíaco por métodos não-invasivosSlomp, Marcio January 1999 (has links)
A aquisição do ciclo pressão-volume é de grande importância para diagnóstico de cardiopatias e principalmente para o acompanhamento de intervenções terapêuticas, porém os métodos hoje utilizados são caros e agressivos ao paciente, reduzindo por estes motivos sua aplicação. Este estudo pretende obter, por métodos não-invasivos, o ciclo pressão-volume do ventrículo esquerdo de pacientes humanos. Isto consiste na aquisição dos sinais P(t) e V(t) simultaneamente e a apresentação de um gráfico P(V). Para tanto, após a revisão bibliográfica, decidiu-se utilizar a ecocardiografia com detecção automática de bordos, para obtenção do volume ventricular e a medição da onda de pressão transmitida através da artéria braquial para um manguito inflado com ar, conectado a um transdutor piezo-resistivo em ponte. A aquisição da pressão pelo método não-invasivo é comparada a dados resultantes da aquisição invasiva da pressão arterial por catéter intra-aórtico que é considerado padrãoouro. Os sinais são condicionados e digitalizados em uma placa de aquisição com conversor A/D de 8 bits e micro controlador 80c196. Os dados digitalizados são então enviados serialmente para um computador onde são gerados os gráficos. Obteve-se de cinco pacientes nove aquisições simultâneas da pressão invasiva através de catéter intra-aórtico e do protótipo desenvolvido resultando concordância segundo o método de Bland e Altman (1986) (r=0,989; d + 2s= 6,52; d - 2s =-6,07), comprovando a eficiência do método de aquisição. Obteve-se resultado satisfatório também quanto à operação sistema desenvolvido pois foram realizadas dez aquisições em cinco pacientes, registrando-se gráficos bastante similares aos apresentados na literatura disponível. / The pressure-volume loop acquisition is very important for diagnoses of cardiac abnormalities and principally to attend the evolution after interventions, but the methods presently used are expensive and aggressive to the patients. Then, due to these reasons their application is reduced. This research has been made with the intention of getting, for non-invasive methods, the left ventricular pressure-volume loop in human patients. This means that it is necessary to acquire the signals P(t) and V(t) and draw a graphic P(V). So, after the bibliographical review it was decided to use echocardiographic apparatus with automated border detection for the obtainment of the ventricular volume and the measurement of the pressure wave transmitted through the brachial artery for a compression cuff, inflated with air, connected to a piezo-resistive transducer. The pressure acquisition by a non-invasively method was compared with an invasively acquired data from arterial pressure performed by an intra-aortic catheter that is used as a golden standard. Nine acquisitions from five patients showed that there is a good correlation between the two methods (r=0,989; d + 2s= 6,52; d - 2s =-6,07) (Bland and Altman, 1986). The signals are conditioned and digitalized on an acquisition board with 8 bit A/D converter and micro controller 80c196. This digitalized data are sent through a serial port to a computer where the graphics are displayed. We obtained ten P(V) loops from five patients showing good similarity with the studied literature.
|
434 |
Estimativa da distribuição espectral da radiação solar sobre o território brasileiro através de análise multiinstrumentalHaag, Rafael January 2012 (has links)
A presente Tese de Doutorado apresenta uma metodologia para caracterizar a distribuição espectral da irradiância solar sobre o território brasileiro através de dados obtidos por instrumentos a bordo de satélites, radiômetros em superfície e radiossondagem. Estas informações formam um banco de dados sobre parâmetros atmosféricos que alteram as características espectrais da irradiância solar. O modelo computacional de transferência radiativa na atmosfera SMARTS2 (Simple Model of the Atmospheric Radiative Transfer of Sunshine) adota este banco de dados como parâmetros de entrada e estima a intensidade e distribuição espectral da radiação solar sobre a superfície terrestre. Através da utilização dos instrumentos MODIS (Moderate Resolution Imaging Spectroradiometer) a bordo dos satélites TERRA e AQUA e AIRS (Atmospheric Infrared Sounder) também instalado na plataforma AQUA, foram determinadas as concentrações e propriedades ópticas de aerossóis, quantidade de água precipitável, coluna de ozônio e dióxido de carbono sobre o território brasileiro. A rede global de radiômetros AERONET (AErosol RObotic NETwork, NASA) foi utilizada para validação da caracterização óptica dos aerossóis e quantidade de água precipitável. Dados das redes SONDA (INPE-CPTEC), SolRad-Net(NASA) e instrumentos instalados no Laboratório de Energia Solar da UFRGS foram usadas para a validação das irradiâncias espectrais e de banda larga previstas pelo modelo computacional SMARTS2. Foram determinadas as características da distribuição espectral em Porto Alegre - RS, Petrolina - PE, Alta Floresta - MT e Manaus - AM e a influência desta distribuição em dispositivos fotovoltaicos de distintos materiais. / This doctoral thesis presents a methodology for characterizing the spectral distribution of solar irradiance over the Brazilian territory through data obtained by instruments aboard satellites, surface radiometers and radiosondes. This information forms a database of atmospheric parameters that alter the spectral characteristics of solar irradiance. The computational radiative transfer model SMARTS2 (Simple Model of the Atmospheric Radiative Transfer of Sunshine) adopts this database as input parameters and estimates the intensity and spectral distribution of solar irradiation on the earth’s surface. By using the MODIS instruments (Moderate Resolution Imaging Spectroradiometer) aboard the TERRA and AQUA satellites and AIRS (Atmospheric Infrared Sounder) also installed on the platform AQUA, concentrations and optical properties of aerosols, amount of precipitable water, total ozone and carbon dioxide column were determined over the Brazilian territory. The global radiometers network AERONET (AErosol RObotic NETwork, NASA) was used for validation of the aerosol optical depth (AOD) and the amount of precipitable water. The networks SONDA (CPTECINPE), SolRad-Net (NASA), and instruments installed at the Solar Energy Laboratory at UFRGS were used to validate the spectral and broadband irradiance provided by the computational model SMARTS2. We determined the characteristics of the solar spectral distribution in Porto Alegre - RS, Petrolina - PE, Alta Floresta - MT and Manaus - AM and its effect on different photovoltaic devices.
|
435 |
Implantação de um guia orientativo de incerteza de medição para avaliadores de laboratório da Rede Metrológica RSJornada, Daniel Homrich da January 2009 (has links)
Esta dissertação aborda a implantação de um guia orientativo de incerteza de medição aplicável aos avaliadores de laboratório da Rede Metrológica RS. A incerteza de medição é um importante tema para organismos de avaliação de laboratórios, como é o caso da Rede Metrológica RS, pois consiste em um dos requisitos básicos para o reconhecimento de competência de laboratórios. Dessa forma, é fundamental garantir que todos os avaliadores possuam um nível de conhecimento adequado sobre incerteza de medição. Assim, o objetivo principal deste trabalho consiste em implantar o referido guia orientativo de incerteza, propiciando melhorias no processo de avaliação da Rede Metrológica RS. Adicionalmente, foi elaborado um fluxograma explicativo dos passos para a expressão da incerteza de medição, assim como listadas componentes de incerteza típicas para áreas de ensaio e calibração e elaborada uma check-list para auxílio aos avaliadores quando da avaliação da incerteza. A implantação do guia orientativo de incerteza dos avaliadores foi realizada segundo as etapas do ciclo de melhoria PDCA. Na etapa plan foram coletados dados que corroboraram para uma necessidade de maior qualificação do grupo de avaliadores com relação à incerteza, sendo a área de ensaios a mais carente. Na etapa do, a minuta do documento foi elaborada de acordo com tópicos previamente definidos com um grupo de especialistas, que envolveu avaliadores experientes e membros da Rede Metrológica RS, assim como especialistas em incerteza do Inmetro. Na etapa check, a minuta do documento passou pela análise crítica do grupo de especialistas consultados e na etapa act foram realizados os ajustes finais e aprovado o documento. Como resultado, foi evidenciada a melhoria do nível de conhecimento dos avaliadores com relação ao tema. Tal fato pôde ser comprovado através da aplicação de provas antes e após o treinamento no novo documento elaborado, mostrando melhoria dos conhecimentos dos avaliadores com relação à incerteza. / This work is concerned with the implantation of a measurement uncertainty guideline applicable to Rede Metrológica RS' assessors. Measurement uncertainty is a quite relevant subject for all laboratory assessment bodies, such as Rede Metrológica RS, because it consists in an elementary requirement for laboratory competence recognition. Thus, it is essential to assure that all assessors have an adequate level of knowledge about measurement uncertainty. Therefore, the main objective of this work consists in the implantation of the referred guideline, yielding improvements on Rede Metrológica RS' assessment process. Additionally, a flow-chart was elaborated to help assessors better understand the procedure to the expression of uncertainty in measurement. A list of common uncertainty sources in calibration and testing fields was prepared, as well as a check-list to help assessors carry out measurement uncertainty assessment. The guideline implementation was carried out following the steps of PDCA improvement cycle. During the step 'plan', some data were collected that corroborated the identified need for better qualification of assessors with respect to measurement uncertainty theory and application. The most deficient field identified was testing assessors. On 'do' step, a guideline draft was prepared in accordance with the topics previously agreed with a group of experts, formed by experienced assessors and Rede Metrológica RS' collaborators, as well as, invited uncertainty experts from Inmetro. On the step 'check', the guideline draft was analyzed by the same group of experts and during the step act, the final adjustments were made and the guideline was formally approved. As a result, an improvement on the assessors' level of knowledge concerning measurement uncertainty was achieved. This was possible to verify by applying assessors' written exams about measurement uncertainty, before and after the training on the new guideline. The exams showed the improvement of the assessors.
|
436 |
Um sistema para medição da movimentação da junta telescópica da coluna de direção veicular em teste de impacto frontalRomera, Germano Francisco Simon 28 February 2011 (has links)
Submitted by Diogo Barreiros (diogo.barreiros@ufba.br) on 2017-02-09T19:14:53Z
No. of bitstreams: 1
DissertacaoMestrado_Germano_Romera_UFBA_28Fev2011.pdf: 11590020 bytes, checksum: 78ab5fa80d846a7cf6ce61f58b1e4a63 (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2017-02-10T12:01:16Z (GMT) No. of bitstreams: 1
DissertacaoMestrado_Germano_Romera_UFBA_28Fev2011.pdf: 11590020 bytes, checksum: 78ab5fa80d846a7cf6ce61f58b1e4a63 (MD5) / Made available in DSpace on 2017-02-10T12:01:16Z (GMT). No. of bitstreams: 1
DissertacaoMestrado_Germano_Romera_UFBA_28Fev2011.pdf: 11590020 bytes, checksum: 78ab5fa80d846a7cf6ce61f58b1e4a63 (MD5) / Existe atualmente na indústria automotiva a necessidade de realizar a medição da movimentação da junta telescópica da coluna de direção em testes de impacto frontal veicular no que se refere ao atendimento às normas de segurança. Trata-se de uma medição problemática em função das características do teste, que envolve elevadas desacelerações, magnitude mensurada que se altera muito rápida e drasticamente, tempo de aquisição dos dados muito pequeno e necessidade de amostragens elevadas para que a medição seja confiável. Os sistemas de medição em uso têm se mostrado deficientes em vários aspectos, inclusive no que concerne à robustez necessária, ou são muito caros. O presente trabalho visa ao desenvolvimento de um sistema de medição para realizar esta tarefa e que supere as restrições dos sistemas atuais, inclusive no quesito custo. Para tal, foi realizada ampla pesquisa conceitual sobre princípios de funcionamento de sensores lineares, culminando na seleção do método de se utilizar os sinais de aceleração integrados no tempo. Erros relacionados a este método de medição também foram analisados e levados em consideração na definição do sistema de medição. A fim de se poder avaliar o método de medição proposto em condições mais próximas possíveis do teste veicular, uma bancada foi projetada e construída para validação. A bancada precisou representar condições que permitam avaliar o sistema de medição para as condições às quais este seria submetido em um teste veicular. Aplicativos computacionais auxiliaram no dimensionamento da bancada e seus componentes, sendo também reportadas nesse trabalho as etapas mais importantes do projeto. Uma vez construída uma bancada pendular, utilizou-se de equipamentos já disponíveis no mercado para a montagem do sistema de medição a ser analisado. Foram utilizados acelerômetros, equipamento de aquisição de dados e câmeras digitais de alta velocidade na aquisição de dados da bancada. As características de resposta do sistema de medição foram avaliadas em função de diversos parâmetros inerentes ao processo de aquisição dos dados, qualidade do sistema de medição e variáveis do processo de integração da aceleração no domínio do tempo. Analisando os resultados obtidos dos ensaios, foi possível concluir que o método de integrar sinais de aceleração no tempo apresenta boas perspectivas de poder ser utilizado em testes de impacto veicular frontal. É esperado, com este trabalho, gerar o incentivo a novas pesquisas referentes ao método de medição de deslocamento por meio da integração de sinais obtidos de acelerômetros.
|
437 |
Desenvolvimento de uma bancada de ensaio de fadiga por impacto em válvulas de compressores de refrigeraçãoPenteado, Pedro Moritz 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Metrologia Científica e Industrial, Florianópolis, 2009. / Made available in DSpace on 2012-10-24T07:27:07Z (GMT). No. of bitstreams: 1
273179.pdf: 4882596 bytes, checksum: 33b3c269ebf2d99d5dbfbf7d5a9501b2 (MD5) / Compressores de refrigeração são projetados para apresentar alta eficiência termodinâmica, alta confiabilidade e baixos níveis de ruído. Essas características são fortemente dependentes do comportamento das válvulas de sucção e descarga. Devido às elevadas cargas mecânicas aplicadas às válvulas, seu projeto exige especial atenção. Entre os possíveis modos de falha, a fadiga de impacto - caracterizada por repetidos impactos da válvula contra o seu assento - é a mais crítica no que concerne à ocorrência e à dificuldade de prevenção.
Desenvolveu-se no presente trabalho uma bancada integralmente automatizada de ensaio de fadiga por impacto de válvulas de sucção, que controla a intensidade do impacto e a freqüência do movimento, permitindo a quebra da válvula sob condições controladas. O número de ciclos suportados é utilizado como indicativo da resistência à fadiga de impacto da válvula analisada.
Resultou um recurso experimental passível de ser utilizado na determinação das propriedades de resistência à fadiga de impacto, que permite a realização de ensaios de conformidade e comparações entre diferentes modelos de válvulas. O sistema desenvolvido gerou uma importante ferramenta de auxílio à pesquisa e desenvolvimento de novos projetos de válvulas para compressores de refrigeração, suprindo uma significativa carência do setor. Este trabalho representa uma inovação tecnológica, por não existirem no mercado sistemas que possibilitem a realização de ensaios de válvulas utilizadas em compressores de refrigeração.
|
438 |
Método para avaliação de incertezas de ensaios de coletores solares baseados nas nornas EN12975 e ISO9806Kratzenberg, Manfred Georg January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Metrologia Científica e Industrial. / Made available in DSpace on 2013-07-16T02:04:27Z (GMT). No. of bitstreams: 1
232404.pdf: 6550559 bytes, checksum: 59ca5c5745eb3d157028bde9a7c54ee0 (MD5)
|
439 |
Comparação das técnicas de medição e análise de incerteza da exposição ao ruído dos usários de fone de ouvidoSteffani, Jovani Antônio January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia de Produção / Made available in DSpace on 2013-07-16T02:15:51Z (GMT). No. of bitstreams: 1
223453.pdf: 4153516 bytes, checksum: ffb5342ddc10ff60e320fe87746b2e36 (MD5) / O avanço técnico-científico, hodiernamente globalizado, provoca a renovação, a transformação e o surgimento de novos meios e métodos de industrialização e comercialização de produtos, como é o caso por exemplo das empresas de telemarketing, que têm despontado nos últimos tempos como uma nova forma de abordar clientes oferecendo os mais variados produtos e serviços. A Associação Brasileira de Telemarketing estima que o volume de transações apoiadas por estes serviços envolva R$ 67,4 bilhões anualmente (6,3% do PIB), empregando mais de 500 mil pessoas em nosso país atualmente. Porém um velho problema acompanha esta nova categoria profissional, o ruído, que pelas características como atinge o sistema auditivo do teleoperador apresenta um novo problema, quanto à metodologia para a sua medição, uma vez que os métodos tradicionais de medição não são adequados para a medição do ruído cuja fonte é suportada diretamente sobre o sistema auditivo através do uso de fones. Devido a este fato buscou-se na literatura internacional 2 metodologias para esse tipo de medição, denominadas de "técnica com microfone em ouvido real" e "técnica com manequim". Na primeira coloca-se um minimicrofone próximo ao meato acústico externo do operador de telemarketing para realizar as medições, e na segunda utiliza-se um manequim equipado com um simulador de ouvido para medir o ruído. Ao aplicar-se as duas técnicas em medições reais e comparar os resultados oferecidos por elas, observou-se que os resultados das medições demonstraram-se muito semelhantes entre si, denotando a aplicabilidade das duas técnicas.
The technical-scientific advance nowadays globalized, leads to a renewal transformation and the appearance of new means and industrialization methods and products commercialization. As an example, there are the telemarketing companies which lately have emerged as a new way to approach clients providing a variety of products and services. The Brazilian Telemarketing Association esteems that transaction involving this service is about $26,8 billions a year (6.3% PIB) employing more than 500 people in Brazil a year. Besides all that, an old problem exists in this professional category, is the noise which damages the workers hearing system, presenting a new issue regarding to the methodologies of mediation. It occurs because the traditional methods are not appropriate to measure the noise which the source is directly supported by the hearing system through the use of phones. Due to this fact, it was searched on international literature two methodologies; one called MIRE technique-microphone in real ear and the other is the manikin technique. In the first technique, a mini microphone is put next to the worker external ear canal to make the mediations; in the second technique a manikin equipped with an ear simulator is used to measure the noise. Applying both techniques in real mediations and comparing the results provided, it was observed that the results have demonstrated similarities among them, indicating the applicability of both techniques.
|
440 |
Medição de tensões residuais por indentação associada à holografia eletrônicaSuterio, Ricardo January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica / Made available in DSpace on 2013-07-16T02:26:01Z (GMT). No. of bitstreams: 1
211427.pdf: 7574973 bytes, checksum: ea03257fad5048a54cd7590a774edcde (MD5) / Este trabalho desenvolve e avalia um novo caminho para medir tensões residuais combinando a holografia eletrônica (ESPI- "Electronic Speckle Pattern Interferometry"), e a indentação. Utilizando-se de um novo conceito de interferômetro, o interferômetro radial, torna-se possível medir o campo de deslocamentos radiais no plano da região de interesse. Ao invés de se produzir um alívio de tensões para quantificar as tensões residuais, o caminho da indução é utilizado, ou seja, são introduzidas deformações plásticas localizadas. O campo de deslocamentos radial resultante ao redor da indentação é medido e, através de um modelo apropriado, o estado de tensões residuais presente na região de interesse é quantificado.
|
Page generated in 0.0398 seconds