• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 168
  • 38
  • 14
  • 5
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 273
  • 128
  • 44
  • 41
  • 37
  • 35
  • 35
  • 33
  • 31
  • 29
  • 28
  • 27
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Análise de superfícies de peças retificadas com o uso de redes neurais artificiais /

Paula, Wallace Christian Feitosa de. January 2007 (has links)
Orientador: Paulo Roberto de Aguiar / Banca: José Alfredo Covolan Ulson / Banca: Amauri Hassui / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: O cenário mundial tem apresentado um ambiente de alta competição industrial, pressionando cada vez mais as indústrias a tornarem seus processos produtivos mais eficientes. Além da eficiência, a precisão é de extrema importância num ambiente onde as empresas tentam manter padrões e procedimentos que se adaptem às normas internacionais. Um dos processos de acabamento mais utilizados na fabricação de componentes mecânicos de precisão é a retificação, e um dos critérios preponderantes na qualidade final de um produto é a integridade superficial, influenciada principalmente por fatores térmicos e mecânicos. Assim, o objetivo deste trabalho foi investigar as relações intrínsecas entre a qualidade superficial de peças retificadas e o comportamento dos sinais correspondentes de emissão acústica e potência de corte para retificação tangencial plana utilizando-se redes neurais artificiais. A caracterização da qualidade superficial das peças foi analisada por meio de parâmetros de queima superficial, rugosidade e microdureza. Verificou-se que o uso de redes neurais artificiais na caracterização da qualidade de superfícies de peças retificadas obteve bons resultados, apresentando-se como uma proposta interessante para implementação de sistemas inteligentes em ambientes industriais. / Abstract: The world scenario has presented a high industrial competition, pressuring each time more the industries to change its more efficient productive processes. Besides efficiency, the precision is of extremely in a world where the companies try to maintain patterns and procedures that fit international demands. One of the most used final processes in the manufacturing of mechanical precision components is grinding, and one of the main criteria in the final quality of a product is its surface integrity, mainly influenced by thermal and mechanical factors. Thus, the objective of this work is to investigate the existing relationships between the surface quality of grinding workpieces and the behavior of correspondent signal of acoustic emission and cutting power to the surface grinding machines using artificial neural network. The characterization of the surface quality of the workpieces was analyzed through surface burning parameters, surface roughness and microhardness. It was verified that the use of artificial neural networks in the characterization of quality of surfaces grinding workipieces had positive results, being presented as an interesting proposal to implementation of intelligent systems in the industrial environments. / Mestre
82

Influência de diferentes protocolos de tratamento da dentina de raízes fragilizadas sobre a resistência de união de pinos fibrorreforçados: avaliação por meio de microscopia confocal, push-out e microdureza / Influence of different treatment protocols of weakened root dentin on the bond strength of glass fiber reinforced post: confocal microscopy, microhardness and push-out evaluation

Altair Soares de Moura 12 December 2014 (has links)
O presente estudo teve como objetivo avaliar, in vitro, a influência de diferentes protocolos de tratamento da dentina intrarradicular de raízes fragilizadas sobre a resistência de união (RU) de pinos fibrorreforçados fixados com diferentes cimentos resinosos. Quarenta e dois caninos superiores humanos tiveram suas raízes padronizadas em 17mm após eliminação das porções coronárias. O preparo biomecânico foi realizado por meio do sistema Reciproc, com instrumento R 50.05 e NaOCl 2,5%. As raízes foram fragilizadas por meio das brocas #4137 e #720G na profundidade de 12mm e obturadas pela técnica da condensação lateral com cimento AH Plus acrescido de Rhodamina B 0,1%. Decorrido 3 vezes o tempo de endurecimento a obturação foi removida e os pinos de fibra de vidro reembasados com resina composta. As raízes foram distribuídas em 3 grupos (n=14) conforme o tratamento da superfície dentinária: NaOCl 2,5%; NaOCl 2,5% + EDTA 17% e; NaOCl 2,5% + EDTA 17% + ultrassom. Em metade dos espécimes de cada grupo a cimentação do pino foi realizada com RelyX U200 e na outra, com Panavia F. Ambos cimentos foram acrescidos de fluoreceína 0,1%. As raízes foram seccionadas transversalmente obtendo-se dois slices de cada terço, um destinado ao teste de push-out e outro, à análise por meio do Confocal e mensuração da microdureza Knoop. Os dados foram submetidos ao teste ANOVA com parcela sub-dividida seguido do teste de Tukey (&alpha;=0,05). Os maiores valores de RU foram observados com o NaOCl + EDTA e NaOCl + EDTA + ultrassom (p>0,01) em relação ao NaOCl isolado (p<0,0001). A Panavia F apresentou maior RU que o RelyX U200 nos espécimes tratados com NaOCl + EDTA e NaOCl + EDTA + ultrassom (p<0,0001), nos três terços radiculares. Não houve diferença entre os materiais cimentantes nos espécimes tratados apenas com NaOCl (p>0,01). Os protocolos não influenciaram a RU do cimento RelyX U200. Em geral a maior incidência de falha foi do tipo adesiva (38,83%), seguido da mista (34,72%) e coesiva (26,45%). O tratamento da dentina com NaOCl + EDTA + ultrassom promoveu a maior redução da microdureza. Concluiu-se que o cimento resinoso Panavia F apresentou os maiores valores de RU nos três terços radiculares e que os protocolos não influenciaram a RU dos espécimes cimentados com RelyX U200 / The present study aimed to evaluate, in vitro, the influence of different treatment protocols of weakened root dentin on the bond strength (BS) of glass fiber reinforced post luted with different resin cements. Forty two upper human canines were sectioned and the root length was standardized on 17-mm after coronary portion was removed. Biomechanical preparation was performed via Reciproc system with R 50.05 instrument and 2.5% NaOCl. The roots were flared using diamond bur #4137 and #720G at a depth of 12mm and filled by the lateral condensation technique with AH Plus sealer modified with 0.1% Rhodamine B. After 3 times the time required to the setting reaction of the sealer the filling was removed and the glass fiber post was relined with composite resin. The roots were divided into 3 groups (n = 14) according to the treatment of dentin surface: 2.5%NaOCl; 2.5%NaOCl + 17% EDTAand 2.5% NaOCl+ 17% EDTA+ ultrasound. Half of the samples of each group had the post luted with RelyX U200 and the other half with Panavia F. Both cements were added with 0.1% fluorescein. The roots were transversely sectioned obtaining two slices of each third, one for the push-out test and the other for the confocal analysis and measurement of knoop hardness. Data were submitted to ANOVA test with sub-divided portion followed by Tukey test (&alpha;= 0.05). The highest BS values were observed for 2.5% NaOCl + 17% EDTA and 2.5%NaOCl + 17% EDTA + ultrasound (p> 0.01) compared to 2.5%NaOClalone (p <0.0001). Panavia F showed higher BS than RelyX U200 in specimens treated with 2.5%NaOCl + 17% EDTA and 2.5% NaOCl + 17% EDTA + ultrasound (p <0.0001) in the three root thirds. There was no difference between the luting materials in specimens treated only with 2.5% NaOCl(p> 0.01). The protocols did not affect the BS of RelyX U200. Overall the higher incidence of failure was adhesive (38.83%) followed by mixed (34.72%) and cohesive (26.45%) failure. Dentin treatment with 2.5%NaOCl+ 17% EDTA + ultrasound promoted the greatest reduction in microhardness. It was concluded that the Panavia F presented the highest BS in the three root thirds and the protocols did not influence the BS of the specimens filled with RelyX U200
83

Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas / Influence of bleaching techniques on the color change and surface microhardness of composites resins

Pedro Turrini Neto 28 March 2008 (has links)
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0,05). Para a microdureza os dados revelaram que a Z250, o tratamento clínico e antes do tratamento apresentaram valores estatisticamente superiores aos demais. Na análise da cor pode-se observar que &Delta;E e &Delta;b apresentaram diferenças significativas para os fatores material, tratamento e entre os grupos, para o &Delta;L a Z250 apresentou-se mais escura que a Supreme. Na comparação do clareamento como o padrão observou-se não haver diferenças significativas entre o &Delta;E e &Delta;L para nenhum fator, porém diferenças significativas apresentaram-se para o &Delta;a e &Delta;b para os fatores material e tratamento. Pode-se concluir que os dois métodos de clareamento foram eficientes em clarear os espécimes a valores próximos ao padrão, sendo mais efetivo o clareamento clínico sem alterar a dureza dos materiais e tendo a Supreme apresentado melhor comportamento que a Z250 no retorno da coloração inicial. / The aim of this study was to evaluate the effects of home bleaching (10% carbamide peroxide) and in office bleaching (37% carbamide peroxide) on the color alteration and microhardness of two composite resins (Z250 and Supreme). For this purpose, it was prepared 100 specimens of resin, 60 for microhardness and 40 for color alteration, with 6mm diameter X 2mm thickness. The matrix was filled in a single increment and the resin was light cured for 20s. Specimens were polished after 24 hours with sandpaper #1200 and diamond paste. In this moment, the first color measurements (standard) and also microhardness measurements were realized. After, in the color study specimens were immersed in coffee for a seven days period, subsequently, a second color measurement was realized. Specimens were randomly divided in three groups for microhardness and two groups for color alteration (n=10) according to bleaching treatment. For the office bleaching were realized in 3 sessions with interval of 7 days among them, and every session were realized 3 applications of the bleach agent for 20 min. For the home bleaching, it was done daily applications with 4h duration by 14 days. Specimens were kept in artificial saliva at 37ºC ± 1ºC during intervals between the bleaching proceedings. A new microhardness and color measurements were realized in the end of the bleaching cycle. Data were submitted to ANOVA and Fisher test (p<0.05) and in relation to microhardness showed that Z250 (material), in office bleaching (treatment) and before bleaching (time) presented higher statistically significant values comparing to the others results. For color alteration showed that &Delta;E and &Delta;b were statistically significant differences for the following factors: material, treatment and interactions, for &Delta;L values, Z250 presented darker than Supreme. In the comparison of bleaching with the standard values, it was not observed statistically significant difference between &Delta;E e &Delta;L for all factors; however, it was observed significant difference to &Delta;a and &Delta;b for the factors material and treatment. It can be concluded that both methods of bleaching were efficient in brightness specimens to values near from standard. Furthermore, in office bleaching was more effective without change materials micro hardness and Supreme presented better behavior than Z250 in relation to return to initial color.
84

Estudo de danos de radiacao de um aco inoxidavel austenico tipo AISI 321 com adicoes de Nb submetidos a tratamentos termicos, mecanicos...rapidos

CAMARGO, MARCOS U. de C. e 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:22Z (GMT). No. of bitstreams: 1 00065.pdf: 1437952 bytes, checksum: 64786e1b696bebb54265a9ec8103c02e (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Energia Atomica - IEA
85

Caracterizacao de liga metalica a base de aluminio-magnesio obtida por metodo convencional apos tratamentos termomecanicos visando estruturas microcristalinas / Characterization of aluminum - magnesium base metallic alloy obtained due conventional after thermomechanical treatments aiming microcrystalline structures

FERRARI, RICARDO B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:00Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
86

Efeito de tratamentos termicos e da adicao de cromo nas propriedades mecanicas de ligas Fe-24 atAl

PAOLA, JEAN C.C. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:27Z (GMT). No. of bitstreams: 1 06112.pdf: 5630844 bytes, checksum: d96c90e096947d42a20110e42e3cc1e8 (MD5) / Dissertacao(Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
87

Estudo dos mecanismos envolvidos no processo de endurecimento superficial a laser de ligas metalicas

SILVA, EDMARA M.R. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:46Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:17Z (GMT). No. of bitstreams: 1 07147.pdf: 12707620 bytes, checksum: d34c7b4c7f15cbdacc704d7fb217bf9d (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
88

Influencia da preparacao previa de amostras de aco AISI H 13 no comportamento a nitretacao

ALMEIDA FILHO, AMERICO de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:26Z (GMT). No. of bitstreams: 1 06769.pdf: 4275325 bytes, checksum: f2158eb766fa7886249500f40de27cec (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares, IPEN-CNEN/SP / FAPESP:97/04424-5
89

Efeito dos elementos substitucional e intersticial na microestrutura e propriedades mecânicas de ligas Ti-x%pNi, x = 5, 10, 15 e 20 / Effect of substitutional and intersticial elements on microstructure and mechanical proprierties of Ti-wtNi, x = 5, 10, 15 e 20 alloys

Cascadan, Daniela [UNESP] 02 May 2016 (has links)
Submitted by Daniela Cascadan null (dcascadan@fc.unesp.br) on 2016-07-14T02:12:57Z No. of bitstreams: 1 tese_final dani_full_12072016.pdf: 13516173 bytes, checksum: 1379fb1f089ab39be04b8b6a43d7a547 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-18T16:21:32Z (GMT) No. of bitstreams: 1 cascadan_d_dr_bauru.pdf: 13516173 bytes, checksum: 1379fb1f089ab39be04b8b6a43d7a547 (MD5) / Made available in DSpace on 2016-07-18T16:21:32Z (GMT). No. of bitstreams: 1 cascadan_d_dr_bauru.pdf: 13516173 bytes, checksum: 1379fb1f089ab39be04b8b6a43d7a547 (MD5) Previous issue date: 2016-05-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Ligas de titânio apresentam grande potencial para uso como biomateriais devido à boa biocompatibilidade e propriedades mecânicas. A adição do níquel ao titânio melhora a resistência ao desgaste, à corrosão e propriedades mecânicas deste elemento. O objetivo deste trabalho foi investigar os efeitos da dopagem de oxigênio na estrutura, microestrutura e em algumas propriedades mecânicas selecionadas de ligas do sistema Ti-xNi%p, x= 10, 15 e 20. Neste trabalho as ligas foram preparadas pela fusão dos metais comercialmente puros em forno a arco voltaico. Para comprovar a composição das ligas obtidas foram feitas análises químicas por emissão óptica por plasma induzido e EDS, que forneceu também o mapeamento dos elementos titânio e níquel para verificar a homogeneidade das ligas. Tratamentos térmicos de homogeneização foram realizados como preparação para a conformação mecânica, no caso a laminação a quente, e após para obter uma microestrutura mais estável, livre de tensões. A seguir foram realizadas dopagens com oxigênio, variando a pressão deste gás e a temperatura, originando amostras com quantidades diferentes de oxigênio. A estrutura foi analisada por difração de raios-X e a microestrutura por microscopia óptica, eletrônica de varredura e EDS para analisar a distribuição dos elementos titânio e níquel nas fases. A quantificação de oxigênio e nitrogênio foi feita por fusão sob gás inerte. As propriedades mecânicas mensuradas foram dureza e módulo elástico dinâmico. Os resultados mostraram que as amostras apresentam a concentração adequada de níquel e boa homogeneidade dos elementos. As ligas apresentam predominantemente as fases alfa e intermetálica Ti2Ni e a quantidade desta aumenta de acordo com a concentração de níquel. Nas amostras Ti15Ni e Ti20Ni este intermetálico reagiu com oxigênio formando o trióxido Ti4Ni2O. As microestruturas variaram de acordo com o processamento, assim como os valores de microdureza. Os valores de módulo elástico estão um pouco acima do titânio devido â formação de uma nova fase intermetálica, mas não variaram significativamente com os processamentos e a dopagem com oxigênio. / Titanium alloys have great potential for use as biomaterials due to the good biocompatibility and mechanical properties. The nickel addition to titanium improves the wear, corrosion and mechanical resistance of this element. The objective of this work was to investigate the effects of oxygen doping on structure, microstructure and on some selected mechanical properties of Ti-xNi wt% (x = 10, 15 and 20) alloys system. In this work, the alloys were prepared by melting of commercially pure metals in arc furnace. To establish the composition of the obtained alloys chemical analyses were made by induced plasma optical emission and EDS, which also provided the titanium and nickel elements mapping to check the homogeneity of alloys. Homogenization heat treatment was performed in preparation for conformation, in the case hot-rolling, and after, to get a more stable microstructure, free of stress. Oxygen doping were made, by varying the pressure of this gas and temperature, resulting in samples with different quantity of oxygen. The structure was analyzed by x-ray diffraction and the microstructure by optical and scanning electron microscopy, and EDS, to analyze the distribution of the elements titanium and nickel in phases. Quantification of oxygen and nitrogen was made by melting under inert gas. The mechanical properties measured were hardness and elastic modulus. The results showed that the samples have the proper concentration of nickel and titanium, and good homogeneity of the elements. The alloys present predominantly alpha and Ti2Ni intermetallic phases and its amount increases according to the nickel concentration. In Ti15Ni Ti20Ni samples this intermetallic reacts with oxygen forming trioxide Ti4Ni2O. The microstructures varied according to the processing, as well as the values of microhardness. The values of elastic modulus are a little above the titanium due to the formation of new intermetallic phase,but not varied significantly with the processing and oxygen doping.
90

Influência do modo de ativação e de uma restauração simulada de porcelana no grau de conversão e na dureza superficial de um cimento resinoso auto-adesivo de cura dual / Influence of polymerization mode and a simulated ceramic restoration on degree of conversion and surface hardness of a dual-cured self-adhesive resin cement

Irma Cunha Matos 28 February 2008 (has links)
Este estudo objetivou analisar o grau de conversão (GC) e a microdureza de um cimento resinoso utilizando diferentes protocolos de ativação, e, caracterizar o cimento quanto à composição monomérica, diâmetro médio das partículas inorgânicas e porcentagem em peso das frações orgânica e inorgânica. Foram preparados quarenta espécimes (8mm de diâmetro, 0,5mm de espessura), sendo metade usada para a determinação do GC e a outra metade usada no teste de microdureza. Os espécimes foram divididos em quatro grupos: GR1 fotoativação realizada diretamente sobre o cimento por 20s, GR2 fotoativação através de um disco de porcelana com 2mm de espessura por 20s, GR3 fotoativação através de um disco de porcelana com 2mm de espessura por 40s, e GR4 fotoativação foi omitida e o material foi polimerizado exclusivamente por seus componentes químicos. A dureza Vickers (HV) e o GC, determinado através de FTIR-ATR, foram realizados imediatamente após a fotoativação (GR1, GR2 e GR3) ou cinco minutos após o início da polimerização (GR4). Após armazenagem em ambiente seco e escuro por 24h, os espécimes foram novamente submetidos aos testes de HV e GC. Para a caracterização do material avaliado, foram realizadas as análises: Termogravimétrica, Espectrometria no Infravermelho, Espectrometria de Ressonância Magnética Nuclear e Microscopia Eletrônica de Varredura. Os resultados foram analisados estatisticamente por ANOVA, teste t e teste de Bonferroni (P&#8804;0,05). Os valores do GC nos períodos imediato e 24h foram, respectivamente: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. Os valores de HV nos períodos imediato e 24h foram, respectivamente: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. A baixa polimerização para o GR4 não permitiu a determinação da dureza inicial e após 24h este valor foi 10.65HV 0.92. O modo de ativação autopolimerizável influenciou negativamente o GC e a HV em relação ao modo de ativação no qual foi utilizada a fotoativação. A restauração simulada de porcelana não influenciou o GC, porém interferiu negativamente na microdureza. O tempo de fotoativação não influenciou os valores do GC e da HV. O GC e microdureza sofreram um aumento significativo após 24h da polimerização inicial, com exceção do GC no período inicial, quando a fotoativação foi realizada através de um disco de porcelana por um tempo de exposição de 20s. Houve uma correlação linear e positiva entre a HV e o GC para o cimento RelyX&#61668; Unicem. Caracterização química: porção orgânica composta por uma mistura de monômeros, tendo o Bis-GMA como monômero-base. Presença de um monômero dimetacrilato contendo hidroxila para se ligar ao ácido fosfórico sob a forma de fosfato. Partículas inorgânicas variando entre 0,4 a 11,2&#61549;m. A fração sólida do material é composta por 96% de partículas inorgânicas. Na fração líquida, a porção orgânica corresponde a 84%. Restou um resíduo incombustível de 16% devido à queima do material em atmosfera de nitrogênio. / The aim of this study was to evaluate the degree of conversion (DC) and the microhardness of a self-adhesive resin cement under different activation protocols, immediately and after 24 hours of the beginning of the polymerization, and, defining cement regarding monomer composition, average diameter of the inorganic fillers and the percentage by weight of the organic and inorganic portions. Forty specimens (8 mm in diameter, 0.5 mm in height) were prepared. Half of them were used to determine DC and the other half were used on the microhardness test. The specimens were divided into four groups: GR1 direct photoactivation for 20s, GR2 photoactivation through 2mm porcelain disc for 20s, GR3 photoactivation through 2 mm porcelain disc for 40 s, and GR4 photoactivation was omitted and curing was reliant on the chemical reaction only. Vickers microhardness (HV) and DC, by FTIR-ATR, were determined immediately after photoactivation (GR1, GR2 e GR3) or after five minutes from the beginning of the polymerization (GR4). After dry storage in the dark, for 24 hours, the samples were submitted to the tests again. In order to define the studied cement, the Thermogravimetric method was applied, as well as the Infrared Spectometry, Nuclear Magnetic Ressonance Spectroscopy and Scanning Electron Microscope. Data were statistically analyzed by one-way ANOVA, t-Test and Bonferroni Test (P&#8804;0,05) and the degree of conversion values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. HV values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. The low DC for GR4 do not permitted to quantify the initial HV value and after 24 hours this values was 10.65HV 0.92. The chemical curing mode showed DC and HV results for both period (initial and after 24 hours), statistically lower than the other groups where the photoactivation was used. The simulated ceramic restoration did not influence monomer conversion, however it negatively influence resin cement hardness. The exposure time did not influence resin cement hardness and monomer conversion. The inical DC and HV were significantly greater than after 24 hours, except for DC for initial period, when the photoactivation was realizded through a porcelain disc for 20s.There was a linear and positive correlation between degree of conversion and microhadness for the self-adhesive resin cement RelyX&#61668; Unicem. Defining the cement: organic portion composed by a mixture of monomers. Bis-GMA is the main monomer. Presence of a dimethacrylate containing hydroxyl to connect to the phosphoric acid as a phosphate. Inorganic fillers raging between 0,4 to 11,2&#61549;m. Powder is composed by 96% of inorganic particles. In liquid fraction, the organic portion corresponds to 84%. There were 16% of waste that did not burn due to nitrogen atmosphere.

Page generated in 0.0332 seconds