• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 5
  • 2
  • 1
  • Tagged with
  • 71
  • 46
  • 40
  • 38
  • 31
  • 28
  • 23
  • 21
  • 19
  • 17
  • 16
  • 14
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on silorane

Rebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
42

Avaliação da microinfiltração marginal e da resistência adesiva em dentes restaurados com inlays de resina composta. Efeito da hibridização imediata do preparo cavitário /

Freitas, Cláudia Regina Buainain de. January 2004 (has links)
Resumo: O objetivo deste estudo foi avaliar o procedimento de hibridização imediata em restaurações indiretas de resina composta. A hipótese nula foi duplicada: os resultados dos adesivos de condicionamento total e auto-condicionante são similares; e a hibridização imediata produz microinfiltração e resistência adesiva similares à cimentação convencional. Foram selecionados 20 terceiros molares humanos recém extraídos e isentos de cárie, nos quais foram realizados preparos cavitários MOD, padronizados para restaurações indiretas. Os dentes foram divididos aleatoriamente em 4 grupos experimentais: (G1) hibridização com adesivo de condicionamento total (SB, Single Bond, 3M ESPE) imediatamente após o preparo cavitário e antes da cimentação, (G2) hibridização com adesivo de condicionamento total antes da cimentação (SB), (G3) hibridização com adesivo auto-condicionante (AP, Adper Prompt, 3M ESPE) imediatamente após o preparo cavitário e antes da cimentação, (G4) hibridização com adesivo auto-condicionante (AP) antes 157 da cimentação. Os espécimes foram restaurados com inlays de Targis (Ivoclar/Vivadent), cimentados com cimento resinoso Rely X ARC (3M ESPE). Todos produtos foram manipulados de acordo com as instruções do fabricante. Após termociclagem, os espécimes foram imersos em solução de nitrato de prata 50%, seccionados para avaliação da microinfiltração com escores pré-determinados de 0 a 3. Em seguida, os espécimes foram novamente seccionados com 0,8mm x 0,8mm para realização dos testes de microtração. Os resultados obtidos foram submetidos à análise estatística (p<0,05). Os escores da microinfiltração foram submetidos ao teste de Mann-Whitney indicando nenhuma diferença na técnica de hibridização (p>0,05). Os resultados da microtração foram submetidos à análise de variância que revelou... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: An analysis was carried out to determine the behavior of immediate hybridization on indirect composite resin restorations. The null hypothesis was two fold: were whether total etch or self-etch (SEA) adhesives result in similar; and whether immediate hybridization produces similar microleakage and æTBS than conventional cementation. Twenty sound extracted teeth were selected and 20 standardized MOD inlay preparations were made. The prepared teeth were randomly assigned in four experimental groups: (G1) hybridization with total-etch adhesive (SB, Single Bond, 3M ESPE) immediately after preparation and prior cementation, (G2) hybridization with total-etch adhesive prior cementation (SB), (G3) hybridization with SEA (AP, Adper Prompt, 3M ESPE) immediately after preparation and prior cementation; and (G4) hybridization with SEA (AP) prior cementation. The specimens were restored with Targis (Ivoclar/Vivadent) inlays, cemented with composite resin cement (RelyX ARC, 3M ESPE). All products were used according with manufacturer's instructions. The specimens were 160 thermocycled and immersed in 50%w/w silver nitrate. The specimens were sectioned and the microleakage evaluated with predetermined scores (0-3). Then, the specimens were sectioned in 0,8mm x 0,8mm and æTBS tested in a MTS-810 machine. The obtained data were submmited to statistical analysis (p< .05). The microleakage scores were submmited to Mann-Whitney non-parametric test showing no statistical differences among the adhesives and technique (p> .05). The æTBS results submitted to ANOVA parametric test reveled that G1 performed better than G2, and G3 superior to G4. The null hypotheses were partially rejected. None of the adhesives eliminate microleakage. Hybridization immediately after the preparation is done and before cementation improved the bond strengths with... (Complete abstract, click electronic address below). / Orientador: Sillas Luiz Lordelo Duarte Júnior / Coorientador: José Roberto Cury Saad / Banca: Welingtom Dinelli / Banca: Marcos Ribeiro Moysés / Mestre
43

Resistência de união entre cimentos resinosos autoadesivos e cerâmicas de zircônia policristalina / Bond strengthof self-adhesive resin cements to polycrystalline zirconia ceramics

Rafael Ferrone Andreiuolo 20 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar a resistência de união a microtração de cimentos resinosos autoadesivos a cerâmicas de zircônia policristalina. Dezoito blocos cerâmicos de zircônia 3Y-TZP (9 LAVA e 9 LAVA Plus) foram jateados com partículas de 50 m de Al2O3por 20 s com pressão de 28 psi a uma distância de 10 mm. Os blocos cerâmicos foram duplicados em resina composta (Point 4, Kerr) por moldagem com silicone. Os blocos de resina composta foram cimentados à superfície jateada da zircônia usando três diferentes cimentos resinosos autoadesivos: (1) RelyX Unicem 2 (3M ESPE); (2) SmartCem 2 (Dentsply); (3) Speedcem (Ivoclar Vivadent). Após 24 h imersos em água destilada a 37oC, os blocos cimentados foram cortados em palitos para testes de microtração,com área da interface adesiva de 1 mm2 0,2 mm, e tensionados até a fratura. Os resultados foram analisados pelo teste de análise de variância de dois fatores e pelo teste de comparações múltiplas LSD (&#945;=0.05). As amostras fraturadas foram analisadas com microscopia eletrônica de varredura (MEV) e o modo de falha foi registrado. A topografia das superfícies cerâmicas antes e após o jateamento foi comparada por microscopia de força atômica (AFM). A resistência de união do cimento Speedcem à zircônia foi estatisticamente superior àquela reportada pelos cimentos RelyX Unicem 2 e SmartCem 2, independentemente da cerâmica usada (p<0,05). O fator cerâmica não teve influência estatística na resistência de união. A interação entre os dois fatores se mostrou significativa (p<0,05). O modo de fratura associado ao SmartCem 2 foi quase exclusivamente adesiva, enquanto oRelyX Unicem 2e o Speedcem exibiram um maior percentual de falhas mistas. Não foram observadas falhas coesivas. O AFM não revelou diferença no padrão de topografia de superfície entre as duas cerâmicas antes ou após o jateamento. Concluiu-se que o cimento Speedcem foi superior na adesão a cerâmicas de zircônia policristalina. / The aim of this study was to evaluate the microtensile bond strength of self-adhesive resin cements to polycrystalline zirconia. Eighteen 3Y-TZP ceramic blocks (9 LAVA and 9 LAVA Plus) were sandblasted with 50 m Al2O3 powder for 20 s with a pressure of 28 psi at a working distance of 10 mm. The ceramic blocks were duplicated in composite resin (Point 4, Kerr) using a silicon mold. Composite blocks were bonded to sandblasted zirconia using different self-adhesive resin cements: (1) RelyX Unicem 2 (3M ESPE); (2) SmartCem 2 (Dentsply); (3) Speedcem (Ivoclar Vivadent). After 24 h immersed in distilled water at 37oC the bonded specimens were cut into microtensile bond sticks of 1 mm2 0,2 mminterface areaand loaded in tension until failure. Data were analyzed by two-way ANOVA and LSDtest for multiple comparisons (&#945;=0.05). The fractured surfaces were observed using a scanning electron microscope (SEM) and the failure mode was recorded. Surface topography of the sandblasted and the as sintered zirconia materials were analyzed under an atomic force microscope (AFM).Bond strength of Speedcem cement to zirconia was significantly higher than that of RelyX Unicem 2 and SmartCem 2, irrespective of the ceramic used (p<0,05). Bond strength was not significantly influenced by the ceramic factor. Interactions were significant (p<0,05). The mode of failure of SmartCem 2 was almost exclusively adhesive, while RelyX Unicem 2 and Speedcem exhibited a good percentage of mixed fractures. No cohesive fractures were observed. AFM did not reveal differences in the topography pattern of the two ceramics before or after sandblasting. It was concluded that Speedcem presented superior adhesion to polycrystalline zirconia ceramics.
44

Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on silorane

Rebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
45

Efeito da temperatura de secagem de dois tipos de silano e da supressão ou redução do tempo de condicionamento com ácido hidrofluorídrico na resistência de união entre uma cerâmica de dissilicato de lítio e um cimento resinoso / Effect of drying temperature of two silan types and elimination or reduction of conditioning hydrofluoridric acid time with the bond strenght between a lithium disilicate ceramic and a resin cement

Leticia Monteiro Peixoto 24 August 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este estudo avaliou o efeito de diferentes métodos de silanização e aplicação do ácido hidrofluorídrico (HF) sobre a resistência à microtração de uma cerâmica de dissilicato de lítio a um cimento resinoso. Quarenta blocos de IPS e.max Press /Ivoclar Vivadent (5x5x6mm) foram cimentados a blocos de resina Z250/3M ESPE (5x5x6mm) usando o cimento resinoso RelyX ARC/3M ESPE de acordo com os seguintes métodos de tratamento superficial: G1: 20s de ácido fluorídrico (HF) + silano não hidrolisado Primer-Activactor/Dentsply (SNH) seco à temperatura ambiente; G2: 20s HF + silano pré-hidrolisado RelyX Ceramic-Primer/3M ESPE (SPH) seco à temperatura ambiente; G3: 10s HF + SNH seco com ar quente (50oC-2min); G4: 10sHF + SPH seco com ar quente (50oC-2min); G5: sem ácido, SNH seco com ar quente (50oC-2min); G6: sem ácido, SPH seco com ar quente (50oC-2min); G7: sem ácido, SNH seco à temperatura ambiente; G8: sem ácido, SPH seco à temperatura ambiente. Antes de cada método de silanização, os blocos cerâmicos receberam acabamento com lixas de carbeto de silício (220-600) e limpeza com ácido fosfórico 37% (1min). A cimentação foi realizada com carga vertical de 1kg por 10min. Os conjuntos de cerâmica/cimento/resina foram armazenados em água destilada (37C) por 24 horas e depois seccionados em máquina de corte Isomet 1000 a fim de obter palitos (n = 40) de 1mm2 de área da seção transversal, que foram submetidos ao teste de microtração em máquina de ensaio universal Emic (v = 0,5mm/min). O modo de fratura foi avaliado em microscópio eletrônico de varredura. A análise estatística foi realizada utilizando ANOVA / Dunnett (p-valor = 0,000). As médias MPa e desvio padrão foram: G1-21,5 (8,9) BC; G2-30,5 (7,2) A; G3-19.4 (9.1) BC; G4-24,0 (9,0) B; G5-8.1 (3.2) D; G6 -18,0 (6,2) C; G7-7.8 (2,6) D; G8-6.3 (2,5) D. Grupos 2, 3, 4 e 6 não tiveram falhas prematuras dos palitos contra os grupos 1, 5, 7 e 8, que apresentaram 2,2; 44,4; 75,6 e 33,3% de perdas prematuras, respectivamente. O teste de correlação foi realizado apresentando significância estatística, com valor de -0,736 (p-valor = 0,000), mostrando que, a medida que o percentual de perda prematura aumenta, a média da MPa diminui. Quanto ao modo de fratura, observou-se 44,97% de falhas do tipo mista, 51,70% de falhas do tipo adesiva, 3,33% de falhas do tipo coesiva do cimento. Quando é realizada a supressão do condicionamento com HF como pré-tratamento da superfície cerâmica IPS e.max Press, a aplicação de silano SPH, associada ao seu tratamento térmico, deve ser o método de silanização recomendado, embora os valores mais elevados de resistência de união tenham sido os obtidos quando utilizado o condicionamento com HF por 20s. Quando é realizada a redução do tempo de condicionamento com HF para 10s, a aplicação do silano (SPH ou SNH) deve ser sempre associada ao seu tratamento térmico. O SNH só deve ser usado se as superfícies das cerâmicas IPS e.max Press forem tratadas com HF. / This study devaluated the effect of different types of silanization and hydrofluoric acid on the microtensile bond strength of a lithium dissilicate ceramic system. Forty IPS e.max Press /Ivoclar Vivadent blocks (5x5x6mm) were cemented to Z250/3M ESPE resin blocks (5x5x6mm) using RelyX ARC/3M ESPE resin-cement according to the following silanization methods: G1: 20s hydrofluoric acid (HF) + non-hydrolyzed silane Primer-Activactor/Dentsply (NHS) dried at room temperature; G2: 20sHF + pre-hydrolyzed silane RelyX Ceramic-Primer/3M ESPE (PHS) dried at room temperature; G3: 10sHF + NHS dried with hot air (50oC-2min); G4: 10sHF + PHS + hot air; G5: NHS + hot air; G6: PHS + hot air; G7: NHS dried at room temperature; G8: PHS dried at room temperature. Before each silanization method, all ceramic blocks were abraded with SiC grit papers (220-600) and cleaned with 37% phosphoric acid (1min). The cementation was made with vertical load of 01 kg for 10 min. After cementation procedure, all ceramic/ciment/resin blocks were stored in distilled water (37oC) for 24h before being cut to obtain stick-shapped specimens (n=45) of approximately 1mm2 cross-sectional area for microtensile test (v=0.5mm/min). Statistical analysis was performed using ANOVA/Dunnett (p-value = 0,000). The mean MPa(SD) values were: G1-21.5(8.9)BC; G2-30.5(7.2)A; G3-19.4(9.1)BC; G4-24.0(9.0)B; G5-8.1(3.2)D; G6-18.0(6.2)C; G7-7.8(2.6)D; G8-6.3(2.5)D. Groups 2, 3, 4 and 6 had no sticks premature fail against groups 1, 5, 7 and 8, that had 2.2, 44.4, 75.6 and 33.3% of sticks premature fails, respectively. As the correlation coefficient was statistically significant, -0.736 (p-value = 0.000), it could be argued that as the percentage of premature loss increased the MPa mean decreases. The failure mode was 44.97% of mixed failures, 51.70% of adhesive failures, 3.33% of cohesive failures of the cement. When the pretreatment is performed without HF conditioning of the IPS e.max Press ceramic surface, then PHS with hot air application should be the silanization method recommended, although higher bond strength values were obtained when HF conditioning for 20s was used with this type of silane. When the time of HF conditioning is reduced for 10 sec, the application of silane (SPH or SNH) must be always related to its heat treatment. NHS should only be used if IPS e.max Press ceramic surfaces are treated with HF.
46

Avaliação in vitro da resistência adesiva e degradação da interface de união entre cimentos resinosos e uma cerâmica aluminizada tratada internamente com laser / In Vitro analsis of bond strength and degradation method between bond interface of aluminous ceramic and resin cements

Bruno Lopes da Silveira 04 July 2008 (has links)
O estudo teve o objetivo de avaliar a resistência adesiva e a degradação da interface entre uma cerâmica tratada com laser e cimentos resinosos. Sessenta e quatro blocos cerâmicos foram distribuídos em 16 grupos distribuídos de acordo com os fatores em estudo: tratamento da superfície interna da cerâmica: Oxido de Alumínio (Ox), Rocatec (R), Laser de Nd:YAG 141,54 J/cm2 (Nd) e Laser de Nd:YAG + Rocatec (NdR); cimentos resinosos: Panavia F (Kuraray) e Relyx Unicem (3M ESPE); e método de envelhecimento: água destilada (W) e hipoclorito de sódio 10% (H). Após os procedimentos de cimentação e corte dos blocos, metade dos palitos foi armazenada em solução de hipoclorito de sódio 10% para simular envelhecimento in vitro. A resistência de união foi avaliada através do ensaio de microtração (0,5 mm/min) e os padrões de fratura foram classificados em adesivo, coesivo ou misto. Blocos cerâmicos adionciais foram confeccionados e analisados em Microscopia Eletrônica de Varredura e em Microscópio de Força Atômica para verificação dos padrões gerados pelos tratamentos. Os grupos tratados com laser de Nd:YAG apresentaram os maiores valores de resistência de união. Para os grupos cimentados com Panavia F, os valores de resistência de união foram: OxW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; OxH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. Para os grupos com RelyX Unicem: OxW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; OxH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Pode-se concluir que o laser de Nd:YAG foi o tratamento mais efetivo, seguido da associação entre o laser de Nd:YAG+Rocatec, Rocatec e jateamento com Al2O3. Os cimentos testados apresentam comportamentos similares. O envelhecimento in vitro com hipoclorito de sódio diminuiu os valores de resistência de união. / The aim of this study was to evaluate the influence of different surface treatments on resistance to degradation between In-Ceram Alumina and two resin-based cements. Sixteen experimental groups were formed according to ceramic treatment: Sandblasting (S), Rocatec System (R), Nd:YAG Laser (Nd), Nd:YAG Laser plus Rocatec System (NR); luting cement: Panavia F (Kuraray) or Relyx Unicem (3M ESPE); and aging method: water (W) or sodium hypochlorite (H). Sixty four In-Ceram Alumina blocks (10x10x6mm) received four surface treatments: Al2O3 sandblasting; Al2O3 sandblasting + Rocatec Plus; Al2O3 sandblasting + Nd:YAG Lase; Al2O3 sandblasting + Nd:YAG Laser + Rocatec Plus. Each conditioned ceramic block was bonded to a composite block using a resin cement system. After 24h storage time, the blocks were sectioned to obtain sticks with cross-sectional area of 1.0mm2. The specimens were loaded to failure in a universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface morphology of the debonded specimens was observed (40X) to evaluate the fracture pattern. Failure modes were classified as adhesive, cohesive in ceramic, cohesive in resin cement and mixed. The ceramic treatment and the aging method significantly affected the microtensile bond strength. Nd:YAG surface treatment resulted in the best bond strength values. To groups luted with Panavia F cement the microtensile bond strength values were: SW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; SH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. To groups luted with RelyX cement: SW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; SH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Nd:YAG laser was the most effective surface treatment, followed by Nd:YAG+Rocatec, Rocatec and Al2O3 sandblasting. Resin cements presented similar behaviors in spite of aging. NaOCl 12h-immersion decreased Bond strength values.
47

Avaliação da resisténcia de união e caracterização da camada híbrida formada por adesivos experimentais a base de metacrilato hidrófobo ou solvatado em 10% e 30% de etanol, aplicados sobre dentina saturada com etanol em um estudo de longevi / Evaluation of bond strength and characterization of hybrid layer produced by an experimental adhesive based on hydrophobic methacrylate or dissolved in 10% and 30% ethanol, applied to ethanol-saturated dentin in a longevity study

Andre Guaraci De Vito de Moraes 20 May 2009 (has links)
A longevidade da interface adesiva é afetada pelos efeitos da degradação hidrolítica, cuja ocorrência está associada ao alto conteúdo de água presente no tecido dentinário. A hibridização da dentina com monômeros hidrófobos em um substrato isento de água poderia fazer com que a resistência de união dessas interfaces se mantivesse estável por um período de tempo prolongado. O objetivo deste estudo foi avaliar a resistência de união, através do teste de microtração, da interface adesiva em dentina saturada com etanol, sobre a qual se fez o uso de um adesivo hidrófobo, além de caracterizar a morfologia desta interface. Vinte e oito dentes molares foram cortados para que um flat de dentina do terço médio fosse obtido. Foram estudados quatro grupos experimentais: Grupo controle (Scotchbond MultiUso, 3M ESPE), cuja dentina foi saturada com água, grupo experimental 1, cuja dentina saturada com etanol foi hibridizada com o adesivo hidrófobo puro do sistema Scotchbond e grupos experimentais 2 e 3, cuja dentina saturada com etanol recebeu primers hidrofóbicos dissolvidos em etanol 10% e 30% respectivamente. Após a hibridização da dentina, os dentes foram restaurados de forma incremental com resina composta (Filtek Z350, 3M ESPE). As resistências adesivas imediata (24 horas) e tardia (6 meses) foram avaliadas por -tração (0.5 mm/min) de palitos obtidos por cortes perpendiculares à interface adesiva, com área de seção transversal de 1 mm2. O meio de armazenagem dos palitos foi saliva artificial a 37°C. Amostras dos palitos foram preparadas para caracterização da interface adesiva e avaliação do modo de fratura em microscopia eletrônica de varredura. Os dados foram submetidos à análise de variância de dois fatores, Técnica Adesiva e Tempo de Armazenamento, sendo este último vinculado. Os resultados encontrados não mostraram diferença estatística para todos os grupos estudados após 6 meses de armazenamento quando comparados com os dados obtidos de forma imediata (24 horas). Também não foram encontradas diferenças entre os grupos quando avaliados em 24 horas e em 6 meses separadamente. A camada híbrida formada em dentina saturada por etanol apresentou características similares, em relação à morfologia e dimensão, àquela formada pela técnica convencional. A técnica de substituição de água por etanol produziu interfaces tão resistentes quanto à técnica úmida convencional, pelo menos nos primeiros seis meses. / The longevity of an adhesive interface is affected by the effects of hydrolytic degradation, which is associated with high water content in the dentin tissue. The hybridization of dentin with hydrophobic monomers in a water-free substrate could make the bond strength of these interfaces remain stable for an extended period of time. The aim of this study was to evaluate the bond strength of the adhesive interface in ethanol-saturated dentin using a microtensile test, on which a hydrophobic adhesive was used, and also to characterize the morphology of this interface. Twenty-eight molar teeth were cut to a flat middle third of the dentin was obtained. We studied four experimental groups: control group (Scotchbond MultiPurpose, 3M ESPE), whose dentin was saturated with water; experimental group 1, whose dentin saturated with ethanol was hybridized with the pure hydrophobic adhesive from Scotchbond adhesive system and experimental groups 2 and 3, whose dentin saturated with ethanol received hydrophobic primers dissolved in ethanol 10% and 30%, respectively. After dentin hybridization, teeth were restored with the incremental technique with composite resin (Filtek Z350, 3M ESPE). The immediate (24 hours) and late (6 months) adhesive resistance was determined by - tensile (0.5 mm / min) of \"sticks\" obtained by perpendicular cuts on the adhesive interface, with cross section area of 1 mm2. The sticks storage medium was artificial saliva at 37 °C. Interface samples were prepared to characterize the adhesive interface and to assess the failure mode by scanning electron microscopy. The data were submitted to two factors analysis of variance, adhesive technique and storage time, the latter being dependent. The results showed no statistical differences for all groups after 6 months of storage when compared to data obtained from the immediate group (24 hours). Also, no differences were found between groups evaluated at 24 hours and 6 months separately. The hybrid layer formed in ethanolsaturated dentin had similar characteristics considering the morphology and size formed by conventional technique. The technique of water replacement for ethanol produced interfaces as strong as the conventional wet technique, at least in the first six months.
48

Avaliação in vitro de diferentes protocolos utilizado na esplintagem dentária / Evaluation in vitro of different protocols used dental splinting

Amaral, Fabricio Reskalla 26 July 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-15T19:46:11Z No. of bitstreams: 1 fabricioreskallaamaral.pdf: 2335161 bytes, checksum: 6c05fb00dba6c1d1e2679f0a3289f9ca (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-26T20:21:13Z (GMT) No. of bitstreams: 1 fabricioreskallaamaral.pdf: 2335161 bytes, checksum: 6c05fb00dba6c1d1e2679f0a3289f9ca (MD5) / Made available in DSpace on 2016-09-26T20:21:13Z (GMT). No. of bitstreams: 1 fabricioreskallaamaral.pdf: 2335161 bytes, checksum: 6c05fb00dba6c1d1e2679f0a3289f9ca (MD5) Previous issue date: 2010-07-26 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / OBJETIVO: Avaliar, por meio do ensaio de microtração, diferentes protocolos utilizados na esplintagem dentária, com fibra de vidro (FV), adesivo (Ad), resina flow (RF) e resina composta nanoparticulada (RCN). MATERIAIS E MÉTODOS: Foram confeccionados 84 blocos de resina nanoparticulada , com dimensões de 4,5 x 8 x 7mm e divididos em 7 grupos. Os blocos foram pareados (n=6) conforme o fator “protocolo de esplintagem”: Gr1- Ad ; Gr2- FV ; Gr3- FV + Ad; Gr4- RF+ FV + Ad; Gr5- FV + Ad + RF; Gr6- FV + RF + Ad; Gr7- RF + FV. Após, os conjuntos foram seccionados com um disco de diamante dupla face em um torno específico para corte dos corpos-de-prova em forma de palito (CP) com interface adesiva de 1mm2 sendo, posteriormente, submetidos ao teste de microtração (µTBS) em máquina de ensaio universal EMIC à velocidade de 1mm/s com célula de carga de 50KGF. Para determinar a fratura, as interfaces adesivas foram analisadas em microscópio eletrônico de varredura e os resultados submetidos à análise de variância ANOVA 1fator e teste Tukey para comparação das médias (α=5%). RESULTADOS: As médias (MPa) e desvio padrão (MPa) para µTBS foram: Gr1- 22,4 (13,4); Gr2- 3,9 (4,2);Gr3- 17,2 (7,7);Gr4- 12,6 (6,9);Gr5- 6,4 (5,5);Gr6- 7,8 (9,7);Gr7-12,1 (10,9). A análise estatística verificou diferença significante entre os grupos. CONCLUSÃO: Houve diferença estatisticamente significante (p< 0.05) na resistência de união entre os protocolos de esplintagem avaliados; o maior valor médio de resistência de união foi obtido pelo protocolo do grupo controle 1 (resina composta + adesivo); entre os grupos testes, o maior valor médio de resistência de união foi obtido pelo protocolo do grupo 3 (resina composta + fibra de vidro + adesivo). / OBJECTIVE: This study evaluated in vitro "different protocols used in the dental splinting with fiber glass (FG), adhesive (Ad), resin flow (RF) and nanoparticle composite (RCN). MATERIALS AND METHODS: We made 84 resin blocks nanoparticule with dimensions 4.5 x 8 x 7 mm and divided into seven groups. The blocks were paired (n = 6) as the factor "protocol splinting": Gr1-Ad; Gr2- FV; Gr3- FV + Ad; GR4- RF + FV + Ad; GR5- FV + Ad + PR; GR6- FV+ Ad + PR +; GR7- RF + FV. After the sets were cut with a diamond disc double-sided on a lathe for cutting specific bodies-of - proof-shaped stick (CP) at the bonding interface of 1mm2 was later submitted to microtensile test (μTBS) in EMIC universal test machine at a speed of 1mm / s with load cell 50kgf. To determine the fracture, the adhesive interfaces were examined in a scanning electron microscope and the results submitted to analysis of variance one-factor ANOVA and Tukey test for comparison of means (α = 5%). RESULTS: Mean (MPa) and standard deviation for μTBS were Gr1-22.4 (13.4); Gr2-3.9 (4.2); Gr3-17.2 (7.7); GR4-12, 6 (6.9); GR5-6.4 (5.5); GR6-7.8 (9.7); GR7-12, 1 (10.9). Statistical analysis found significant differences between groups. CONCLUSION: CONCLUSION: There was a statistically significant difference (p <0.05) in bond strength between splinting protocols evaluated, the larger value of bond strength was obtained by the filing of a control group (resin + adhesive) between the test groups, the highest average value of bond strength was obtained by the protocol of group 3 (composite resin + glass fiber + adhesive).
49

Tetrahidrofurano como solvente de adesivos odontológicos / Tetrahydrofuran as solvent in dental adhesive systems

Fontes, Silvia Terra 27 February 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_ Terra_Silvia_ Fontes.pdf: 826039 bytes, checksum: 1168fd40390593dc923413d4c46c356d (MD5) Previous issue date: 2009-02-27 / The aim of this study is to evaluate the performance of tetrahydrofuran (THF) as solvent in the primer composition of an experimental adhesive system on the resin-dentin microtensile bond strength after 24h and 6 months of water storage. Sixty bovine incisors will be randomly separated into ten groups, according to the solvent type: 1) THF, 2) acetone, 3) ethanol, 4) water, 5) THF/water, 6)acetone/water, 7) ethanol/water, 8) All Bond 2 (acetone/ethanol/water), 9) Opti Bond FL (ethanol/water) e 10) Scotch Bond (water). Vestibular enamel will be removed to, expose the superficial dentin and further polished with grit silicon-carbide under irrigation. After acid etching with 35% phosphoric acid (15s), the surfaces will be rinsed with water (30s) and the excess of superficial water will be removed with absorbent paper. Each experimental primer will be applied with agitation (30s) followed by a gently air stream (10s) at a distance of 10cm to help solvent evaporation. One coat of an experimental adhesive resin will be applied and lightactivated (20s). The marketed available adhesive systems will be used according manufacturer instructions. Resin composite restorations will be constructed incrementally. Each layer of composite will be light-activated individually at 1400mW/cm2. After water storage for 24h at 37oC, the restored teeth will be sectioned to obtain sticks with a cross-sectional area of approximately 0.5mm2. Half of specimens will be tested after 24 hours and the other half will be maintained in the same storage conditions to be evaluated after 6 months. Microtensile bond strength (MPa) will be evaluated with an universal testing machine (1.0mm/min/100N). The half corresponding to dentin will be evaluated in a light microscope (500X) and classified as: CD) cohesive in dentin, CC) cohesive in resin composite, A) adhesive, M) mixed or PD) premature debonded. Statistical significance will be set at α=0.05 / O objetivo deste estudo será avaliar o desempenho do tetrahidrofurano (THF) como solvente na composição do primer de um adesivo odontológico experimental através da resistência de união à microtração em dentina após 24h e 6 meses de armazenamento em água. Sessenta incisivos bovinos serão distribuídos aleatoriamente em dez grupos, conforme o tipo de solvente: 1) THF, 2) acetona, 3) etanol, 4) água, 5) THF/água, 6) acetona/água, 7) etanol/água, 8) All Bond 2 (acetona/etanol/água), 9) Opti Bond FL (etanol/água) e 10) Scotch Bond (água). O desgaste na face vestibular dos dentes será realizado até exposição da dentina superficial com lixas de carbeto de silício sob refrigeração. Depois que a superfície dentinária for condicionada com gel de ácido fosfórico a 35% (15s) e lavada com água (30s), o excesso de água superficial será removido com papel absorvente. Nos grupos experimentais, o primer será aplicado sob agitação constante (30s) seguido de jato de ar por (10s) a distância de 10cm, a fim de auxiliar a evaporação do solvente. Uma camada de resina adesiva experimental será aplicada e fotoativada (20s). Os sistemas adesivos de marcas comerciais serão aplicados conforme instruções dos fabricantes. As restaurações serão realizadas com compósito restaurador pela técnica incremental. Os incrementos serão fotoativados individualmente a 1400mW/cm2. Após o período de 24 horas de armazenamento em água a 37ºC, as amostras serão seccionadas obtendo-se uma área de secção transversal de aproximadamente 0,5mm2. Metade dos corpos de prova será testada imediatamente e a outra metade será mantida sob as mesmas condições de armazenamento para avaliação após 6 meses.A resistência de união à microtração (MPa) será testada através de uma máquina universal de ensaios mecânicos (1,0mm/min/100N). As porções correspondentes à dentina serão analisadas por microscopia de luz (500X) e classificadas de acordo com o padrão de fratura em: CD) falhas coesivas em dentina, CC) falhas coesivas em compósito restaurador, A) falhas adesivas, M) falhas mistas ou FP) falhas prematuras. Significância estatística será considerada quando α=0.05
50

EFEITOS DO PRÉ-TRATAMENTO DENTINÁRIO E TEMPERATURA DO ADESIVO NA RESISTÊNCIA ADESIVA DE UM SISTEMA ADESIVO UNIVERSAL / EFFECTS OF DENTIN PRETREATMENT AND ADHESIVE TEMPERATURE ON BOND STRENGTH OF A UNIVERSAL ADHESIVE SYSTEM

Sutil, Bruna Gabrielle da Silva 28 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed to evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and total-etch (TE) mode, adhesive temperature (20ºC or 37ºC) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm² were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a universal testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using to two-way ANOVA and Tukey s test (p<0.01). Interaction between treatment and temperature was statistically significant to SbU applied in SE technique. Both dentin treatments showed higher bond strength to TE mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE mode. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Thus, the dentin pretreatment may be an alternative to improve the adhesive properties of the Scotchbond Universal adhesive system. / O presente estudo avaliou os efeitos do jateamento de partículas abrasivas e da temperatura sobre a resistência adesiva de um sistema adesivo universal à dentina. Utilizou-se 96 terceiros molares humanos hígidos e extraídos, divididos aleatoriamente em 12 grupos (n=8) de acordo com o adesivo Scotchbond Universal (SBU) aplicado no modo autocondicionante (SE) ou condicionamento ácido total (TE), temperatura do adesivo (20ºC ou 37ºC) e jateamento da dentina com partículas de óxido de alumínio ou bicarbonato de sódio. Após a realização das restaurações, foram obtidos espécimes em forma de palito com área seccional de 1 mm² para avaliar a resistência adesiva através do teste de microtração. O teste foi realizado em uma máquina de ensaio universal, a uma velocidade de 0,5 mm/min até a fratura ocorrer. As fraturas foram analisadas sob estereomicroscopia para classificar as falhas em adesiva, coesiva (resina ou dentina) e mista. Os dados foram submetidos ao teste ANOVA a dois fatores e ao teste de Tukey. A interação entre tratamento e temperatura foi estatisticamente significante (p<0,01) para SBU SE. Ambos os tratamentos da dentina resultaram em valores maiores de resistência adesiva para SBU no modo TE, independente da temperatura do adesivo. Já para SBU aplicado na técnica autocondicionante, apenas o jateamento com bicarbonato de sódio foi significativamente diferente quando comparado ao grupo que não recebeu tratamento. O adesivo aquecido não teve influência significativa sobre a resistência adesiva à microtração, para todos os grupos testados. As fraturas adesivas foram predominantes para todos os grupos. Dessa forma, o pré-tratamento dentinário pode ser uma alternativa para melhorar as propriedades adesivas do sistema adesivo Scotchbond Universal.

Page generated in 0.4251 seconds