• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Vyhodnocení vlivu tvaru otvorů clonek na výsledný tlak na dráze sekundárních elektronů v detektoru pomocí systému CAE / Using Computer Aided Engineering for analyse the detector

Novotný, Marek January 2011 (has links)
This diploma thesis deals with electron microscopy. Examined equipment is environmental scanning electron microscope (ESEM), namely scintillation a detector of the microscope. There is solved the influence of the profile of holes in diaphragms to the resulting pressure and gas flow on the path of secondary electrons at the detector. Introductory part of thesis informs about microscopy in general, with concentration on electron microscopy; especially on scanning microscope, because research is taken just on the environmental scanning electron microscope. Another part informs about both general principles of dynamics of gases and with finite volume method. Another part deals with concrete used software and with setting of individual parameters for calculation. At the beginning of calculation are used five basic profiles of holes in diaphragms for pressure 1000 Pa in the chamber of the sample. For modelling individual shapes is used 3D parametric modeller SolidWorks. Analysis of circulation of secondary electrons through detector is made by using Cosmos FloWorks module. The most suitable type of diaphragms is chosen from measured models. Another part of diploma thesis deals with measuring of chosen types of diaphragms for more pressures in the chamber of the sample; the pressure is 200, 400, 600, 800 and 1000 Pa. The outcomes of this research are both models of pressure and speed of circulation inside the detector and graphically processed values by using different diaphragms, respectively one type of a diaphragm in different pressures. Production drawings of each diaphragm, together with calculated models, are enclosed.
2

Analýza tvaru sacích kanálů současné koncepce diferenciálně čerpané komory / Analysis of the shape of the intake ports of the current concept differentially pumped chamber

Bílek, Michal January 2015 (has links)
This master´s thesis discusses the analysis of the shape of the intake ports of differentially pumped chamber for the current concept. The first part is an introduction to the microscopy issue, then it is focused on ESEM microscopes and it also includes a describtion of the Flow dynamics and a mathematical describtion. In the following chapters the software Solid Works, where the model of differentially pumped chamber is created, and the software Ansys Fluent, which is used for analysis, are described. The second part concerns the proposed concepts and the results of their simulations. At the end of the work the results are analyzed and evaluated.
3

Johann Friedrich von Uffenbach. Sammler – Stifter – Wissenschaftler / Johann Friedrich von Uffenbach. Collector - Donor - Scientist

Meyerhöfer, Dietrich 28 January 2020 (has links)
No description available.

Page generated in 0.0414 seconds