111

Evidências científicas na utilização de pinos de fibra de vidro e núcleos metálicos fundidos / Scientific evidences on the use of glass fiber posts and cast metal posts

Moraes, Aline Pinheiro de 07 November 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-18T17:43:22Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Evidências científicas na utilização de pinos de fibra de vidro e nucleos metálicos fundidos.pdf: 3303685 bytes, checksum: 0b79b726661436d448f803f2526b28df (MD5) / Made available in DSpace on 2017-05-18T17:43:22Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Evidências científicas na utilização de pinos de fibra de vidro e nucleos metálicos fundidos.pdf: 3303685 bytes, checksum: 0b79b726661436d448f803f2526b28df (MD5) Previous issue date: 2014-11-07 / Sem bolsa / Tradicionalmente, os metais têm sido utilizados como retentores intrarradiculares como meio para fornecer ancoragem às restaurações devido às suas propriedades físicas adequadas e possibilidade de serem fundidos ou usinados em formas precisas. No entanto, a crescente demanda por estética tem levado ao desenvolvimento de retentores mais estéticos sendo especialmente os de fibra de vidro considerados uma alternativa aos núcleos metálicos fundidos (NMFs) na restauração de dentes tratados endodonticamente. Considerando ambos os tipos de retentores intrarradiculares, este estudo foi dividido em quatro partes. Na primeira, foi realizada uma revisão narrativa de literatura sobre os conceitos atuais na utilização de pinos de fibra de vidro. De maneira geral, concluiu-se com que o uso de pinos de fibra de vidro é uma importante opção clínica, mas deve-se tomar especial atenção às dificuldades de se obter uma boa adesão ao longo do canal radicular. Na segunda parte, foi realizada uma revisão sistemática na qual se avaliou se a utilização de silano seria benéfica para a resistência de união de pinos de fibra de vidro. Esta revisão mostrou que embora haja pouca evidência na literatura, a silanização pode melhorar a retenção de pinos de fibra de vidro quando tratamentos físicos/químicos seletivos são aplicados ao pino antes da silanização. Na terceira parte, foi realizado um estudo in vitro com o objetivo de comparar como os operadores com diferentes níveis de expertise e as técnicas de moldagem intracanal (direta ou indireta) influenciariam nas características de superfície das moldagens e qualidade dos núcleos metálicos fundidos. Os resultados mostraram que ambos os operadores e técnicas de moldagem resultaram em núcleos metálicos fundidos clinicamente aceitáveis de acordo com os padrões internacionais. No ensaio clínico randomizado foi avaliada a qualidade dos núcleos metálicos fundidos em relação a sua adaptação dependendo da posição do dente no arco e a técnica de moldagem realizada. Os resultados mostraram NMFs mais curtos quando a técnica indireta foi utilizada. No entanto, independentemente da técnica todos os pinos fundidos ficaram mais curtos do que o que foi moldado, embora clinicamente aceitáveis. A técnica indireta mostrou-se mais rápida do que a técnica direta, sendo este achado especialmente importante quando planejados casos de moldagens múltiplas e/ou espaço interoclusal reduzido. Desta forma, podemos concluir que os dados do estudo in vitro corroboram com os dados do ECR, uma vez que independentemente da técnica de moldagem, dos operadores e da posição do dente no arco, todos os núcleos metálicos fundidos foram mais curtos do que o que foi moldado, embora clinicamente aceitáveis. / Traditionally, metals have been used to fabricate dental posts because of their suitable physical properties and possibility of being cast or machined into precise shapes. However, in recent decades, the increasing demand for aesthetics has led to the development of glass fiber posts. Glass fiber posts are considered an alternative to cast metal posts to restore endodontically treated teeth. Considering both types of intracanal posts, this study was divided into four parts. In the first, a narrative literature review of current concepts in the use of glass fiber posts was performed. In general, it may be said that the use of fiber posts is an important clinical option in Dentistry, but clinicians should be aware of the difficulties in achieving good adhesion within the root canal. In the second part, a systematic review evaluated if the use of silane would be beneficial to the bond strength of glass fiber posts. This review showed that although there is little evidence in the literature, silanization might improve the retention of glass fiber posts luted into root canals provided that selective physical/chemical surface treatments are applied to the post before silanization. In the third part, an in vitro study compared how operators (experienced or not) and intracanal impression techniques (direct or indirect) influenced the surface characteristics of the impressions and the quality of cast metal posts. Results showed that both operators and techniques resulted in clinically acceptable posts according to international standards. The fourth part of this study evaluated the accuracy of cast metal posts depending on the tooth position and impression technique performed on a randomised controlled trial. Results showed that cast metal post were shorter than their respectvive impressions for all variables tested, but resulted in clinically acceptable metal posts. However, the direct technique was more time-consuming than the indirect technique, which is especially important in cases of multiple teeth involved and/or reduced interarch space. Thus, it may be concluded that data from the in vitro study corroborated with the RCT, as irrespective of the impression technique, operator level of expertise or the position of the tooth in the arch all cast metal posts were shorter, but clinically acceptable.
112

Influência de técnicas e materiais de moldagem na precisão de modelos de trabalho obtidos para a confecção de prótese fixa convencional e sobre implante / Influence of techniques and impression materials on the accuracy of working casts obtained for the confection of conventional and implant-supported fixed prosthesis

Vargas, Fernando Fernandes 20 February 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-14T11:46:02Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência de técnicas e materiais de moldagem na precisão de modelos de.pdf: 759210 bytes, checksum: 1bd252ce92c5a18682ec4a9120348f75 (MD5) / Made available in DSpace on 2017-07-14T11:46:02Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência de técnicas e materiais de moldagem na precisão de modelos de.pdf: 759210 bytes, checksum: 1bd252ce92c5a18682ec4a9120348f75 (MD5) Previous issue date: 2017-02-20 / Sem bolsa / De acordo com a literatura, os materiais de moldagem disponíveis no mercado sofrem alteração dimensional após sua presa. Essa distorção pode afetar a precisão e, consequentemente, a adaptação final de próteses parciais fixas convencionais e sobre implantes. O objetivo do presente estudo foi de investigar e comparar, através do uso de escaneamento tridimensional e software de comparação de superfícies, as alterações tridimensionais decorrentes do procedimento de moldagem e obtenção de modelos de trabalho utilizando diferentes materiais e técnicas de moldagem comumente usadas na prática odontológica. Um modelo mestre para dentes contendo um incisivo central e um canino superiores preparados para receber prótese fixa de três elementos livre de metal e outro modelo contendo dois análogos de implantes com conexão hexagonal externa foram obtidos. Os grupos (n=5) foram divididos de acordo com a técnica (dupla mistura, moldagem única e com casquete para dentes e direta e indireta para implantes) e material de moldagem (silicone de adição, silicone de condensação e poliéter). A avaliação e comparação das superfícies com o modelo mestre foram realizadas através de escaneamento 3-D (S600 ARTI, Zirkonzahn) e software de análises específico (Geomagic Qualify v.13, Geomagic Inc). Os resultados obtidos foram submetidos à análise estatística que demonstrou não haver diferença significante entre as técnicas de moldagem tanto para dentes quanto para implantes; porém, no caso dos materiais de moldagem, os modelos de trabalho obtidos à partir de moldagens com silicone de condensação apresentaram menor distorção que os modelos obtidos com os demais materiais. Entretanto, os valores de variação foram bastante pequenos e talvez não apresentem significância clínica. Baseado no que foi exposto, pode-se concluir que o cirurgião-dentista deve escolher a técnica e o material que considera mais apto a utilizar em moldagem para próteses fixas, tanto sobre dentes quanto sobre implantes. / According to the literature, all the available impression materials on the market deform after its polymerization. This distortion can affect the precision and, consequently, the marginal fit of fixed partial dentures on teeth or implants. The aim of this study was to investigate and compare, through the use of three-dimensional scanning and surface comparison software, the dimensional changes of working cast originated from different impression techniques and materials commonly used on the dental practice.. Master casts containing a maxillary central incisor and a canine prepared to receive a three-unit metal-free fixed partial denture and two external hex implant analogues were made. Groups (n=5) were divided according to the technique (dual mixture, single impression and custom tray for teeth; and direct or indirect for implants), and impression material (polyvinyl siloxane, polydimethylsiloxane and polyether). Evaluation and comparison of the surfaces between master cast and specimens were performed with a fully automated optical structured-light scanner (S600 ARTI, Zirkonzahn) and Geomagic Qualify v.13 (Geomagic Inc.) software inspection tool. The obtained results were submitted to statistical analysis, which showed that there was no significant difference between the impression techniques for both teeth and implants groups; however, in regard of impression materials, working casts obtained by polydimethylsiloxane impressions showed lower volumetric distortion than casts obtained with the other impression materials. However, the distortion values were very small and may not be clinically significant. Based on the above, it can be concluded that the dentist could choose the impression technique and material that he considers most suitable for fixed prostheses teeth or implant-borne prostheses .
113

Influência de técnicas de moldagem e de dois vazamentos na precisão dimensional de modelos de gesso e adaptação marginal de infraestruturas CAD/CAM em Y-TZP /

Messias, Aion Mangino. January 2015 (has links)
Orientador: José Maurício dos Santos Nunes / Banca: Francisco de Assis Mollo Júnior / Banca: Mauro Antonio de Arruda Nóbilo / Resumo: Este estudo objetivou analisar a exatidão de modelos de gesso, a partir de diferentes técnicas de moldagem e segundos vazamentos de gesso, bem como mensurar o desajuste marginal de infraestruturas de zircônia sobre preparos dentais reproduzidos nesses modelos. Um modelo mestre, com preparos para coroa total nos dentes 14, 16, 21 e 25, foi obtido e infraestruturas em zircônia CAD/CAM foram confeccionadas. Moldes totais com moldeira de estoque e silicone de adição foram obtidos a partir de três técnicas de moldagem (n=15): T1) mistura simultânea; T2) reembasamento - alívio com filme de PVC e T3) reembasamento - alívio com movimentação da moldeira. Foram aguardados 120 min para o 1º. vazamento de gesso (Tipo IV). O 2º. vazamento foi realizado 120 min após a remoção dos primeiros modelos. Para a mensuração da adaptação marginal das infraestruturas utilizou-se estereomicroscópio LEICA (50x). Para a análise da precisão dimensional linear, os modelos foram fotografados e, a partir de pontos pré-definidos, mensurações oclusais lineares latero-laterais (LL) e anteroposteriores, direita (APD) e esquerda (APE), foram realizadas (ImageJ). Mensurações das dimensões mésio-distais (MD) e vestíbulo-linguais (VL) dos preparos e da distância interpreparos do segmento 14-16 foram realizadas. Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independente do vazamento (1º ou 2º). Após 1º. vazamento, a técnica simultânea apresentou tendência a apresentar valores de desajuste menores do que as demais técnicas. Com exceção da dimensão MD do dente 21, a técnica simultânea produziu dimensões MD e VL similares ao modelo mestre. Não houve...(Resumo completo clicar acesso eletrônico abaixo) / Abstract: This study conducted laboratory analysis of dental casts' accuracy obtained from different impression techniques and two castings, as well as measure the cervical marginal fit of zirconia infrastructures on dental preparations played in these models. Master model was used, with crown preparations in the teeth 14, 16, 21 and 25, on which zirconia infrastructures were made by CAD/CAM technology. For each impression technique full molds (n=15) were obtained by a single calibration operator with stock tray and polyvinylsiloxane: (T1) simultaneous mixture; (T2) reline - relief with PVC film and (T3) reline - relief with small movement of the tray. After mold removal, it was expected 120 min to realize the first pouring (type IV gypsum). The second pouring was made after 120 min from the removal of the first cast. To measure the marginal adaptation of infrastructure was used stereomicroscope LEICA (50x). For the analysis of linear dimensional accuracy, the models were photographed and, from pre-defined points, linear lateral-side occlusal measurements (LL) and anteroposterior, right (RPA) and left (EPA), were performed (ImageJ). Measurements of mesiodistal dimensions (MD) and bucco-lingual (VL) of the preparations and interpreparos distance segment 14-16 were performed. After verification of distribution and homocedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of the time of pouring (1º ou 2º). After 1st. pouring, the simultaneous technique tended to have lower misfit values than other techniques. Aside from tooth MD dimension 21 simultaneous technique produced dimensions MD and BL similar to the master model. No differences in inter-preparation linear dimensions and the occlusal line...(Complete abstract electronic access below) / Mestre
114

Estudo da produção de embalagens plásticas e desenvolvimento de testes de qualidade

Nogueira, Idelfonso Bessa dos Reis January 2012 (has links)
Trabalho realizado no Grupo Indeba (ndústria de Detergentes da Bahia) /SPAR (Unidade de Produção de Embalagens Plásticas), orient. pelo Eng. Donato Cuozzo / Tese de Mestrado Integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2012
115

Infiltração de fluidos carregados em meios porosos via processo RTM: análise teórica e experimental. / Infiltration of charged fluids in porous media via RTM process: theoretical and experimental analysis.

OLIVEIRA, Iran Rodrigues de. 24 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-24T16:54:35Z No. of bitstreams: 1 IRAN RODRIGUES DE OLIVEIRA - TESE PPGEP 2014..pdf: 8399659 bytes, checksum: a53ba70ec49d8f5448c637ec5198e35e (MD5) / Made available in DSpace on 2018-04-24T16:54:35Z (GMT). No. of bitstreams: 1 IRAN RODRIGUES DE OLIVEIRA - TESE PPGEP 2014..pdf: 8399659 bytes, checksum: a53ba70ec49d8f5448c637ec5198e35e (MD5) Previous issue date: 2014-08-22 / Este trabalho tem como objetivo realizar um estudo teórico e experimental do processo de moldagem por transferência de resina (RTM), com a adição de carbonato de cálcio (CaCO3), na manufatura de compósitos de matriz poliéster reforçados com fibras de vidro. Realizou-se experimentos em molde com dimensões da cavidade de 320 x 150 x 3,6 mm, temperatura ambiente, pressão de injeção máxima de 0,25, 0,50 e 0,75 bar, volumes de fibras de 19, 24 e 30% e teores de CaCO3 (0, 10, 20, 30 e 40%), e simulou-se a infiltração retilínea de resina no molde via software comercial PAM-RTM. Resultados da posição da frente de fluxo e tempo de preenchimento do molde são apresentados, analisados e comparados com os resultados obtidos via software a fim de se investigar o comportamento do escoamento e estimar a permeabilidade do meio usando o método do erro mínimo quadrático. Conclui-se que o uso de CaCO3 na resina poliéster, dificulta o preenchimento do meio fibroso durante processo de moldagem do RTM, e afeta a permeabilidade, mobilidade e viscosidade da resina, e o tempo de preenchimento do molde. Observou-se também que as distribuições granulométricas ficaram próximas, enquanto que, na análise microscópica ver-se somente área sem fibras e sem CaCO3. Os resultados numéricos obtidos com o simulador apresentaram boa concordância com os dados experimentais em termos de posição da frente de fluxo, tempo de preenchimento e pressão de injeção. / This paper aims to conduct a theoretical and experimental study of the process of resin transfer molding (RTM), with the addition of calcium carbonate (CaCO3) in the resin, in the manufacture of polyester matrix composites reinforced with glass fibers. Experiments were carried out in a mold with cavity dimensions 320 x 150 x 3.6 mm, at room temperature, maximum injection pressure of 0.25, 0.50 and 0.75 bar, fiber volume fraction of 19, 24 and 30% and CaCO3 concentrations (0, 10, 20, 30 and 40%) and simulated in rectilinear infiltration of resin in the mold via software commercial PAM-RTM. Results of the flow front position and mold filling time are presented, analyzed and compared with results obtained via software in order to investigate the behavior of the flow and to estimate the permeability of the medium using the method of least squares error. It is concluded that the CaCO3 used in the polyester resin hinders the filling of the fibrous medium for the RTM molding process and affects permeability, resin mobility and viscosity, and the filling time of the mold. It was also observed that the granulometric size distributions were next, while that, in the microscopic analysis seen only fiber area and without CaCO3. The numerical results obtained with the simulator showed good agreement with experimental data in terms of the position of the flow front, filling time and injection pressure.
116

Precisão das técnicas de moldagem e vazamento para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1 delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
117

Estudos para obtenção da liga NiTi pelo processo de moldagem de pós por injeção

Luna, Wilberth Harold Deza January 2008 (has links)
Os avanços da moldagem de pós por injeção – MPI – associados às excelentes propriedades da liga NiTi abrem novas possibilidades em diferentes áreas da engenharia. A MPI é um processo de fabricação que facilita a elaboração de diversos componentes, podendo-se obter peças de geometrias complexas a um menor custo. O NiTi ou Nitinol® é uma liga que pertence ao grupo dos chamados materiais inteligentes, por ter propriedades como memória de forma e superelasticidade, além disso, essa liga é um material biotolerante por ter titânio na sua composição. O objetivo deste trabalho é estabelecer os parâmetros para a produção de Nitinol® pelo processo MPI visando à confecção de implantes de fixação óssea. Assim, com o objetivo de melhorar o desempenho do processo MPI, este estudo utiliza diferentes cargas injetáveis (feedstock), modificando quantidades de pó na carga injetável e também modificando cada um dos componentes do ligante (binder), de modo a determinar aquela que permite a melhor extração do polímero, corrigindo assim uma das principais fontes de contaminação. A extração química e térmica do ligante é uma etapa também estudada na pesquisa, nessa etapa é analisada a influência da morfologia dos pós na contaminação final das amostras, já que a quantidade de polímero restante após a extração do ligante reagirá diretamente com a matéria prima (Ni – Ti). São estabelecidos ciclos de temperatura para a sinterização da liga. / Advances in Powder Injection Molding (PIM), allied to the great properties of NiTi alloy, offer new possibilities on different areas of engineering. MIP is a process that makes the factory of many compounds easier, allowing to make pieces with complex geometry in minor cost. NiTi or Nitinol® is an alloy that belongs to the “smart materials”, because it has properties as shape memory and superelasticity. Besides, this alloy has good biotollerance because of the titanium. This research means to establish parameters to the production of Nitinol® by PIM process, for bone implants. Therefore, to improve the PIM process, this study applies different feedstock, changing amounts of powder of the injection and also changing each of the components of the binder, in order to determine which one allows the best extraction of the polymer correcting one of prime sources of contamination. Chemical and thermal extraction of the binder was also studied on this research, analyzing the influence of the morphology of the powder on the final contamination of the samples, since the polymer that was left after the binder extraction will react directly with the prime material (Ni-Ti). Temperature cycles are established to the sintering of the alloy.
118

Desenvolvimento de um mini motor de passo à partir da moldagem por injeção de pós metálicos

Pfingstag, Maiquel Emerson January 2014 (has links)
Neste trabalho foi projetado o núcleo de um mini motor de passo, com rotor e estator, obtidos a partir do processo de Moldagem de Pós por Injeção (MPI). Foram avaliadas as propriedades magnéticas, elétricas e mecânicas da liga FeNi50 obtida pelo processo MPI. Também por metalurgia do pó convencional obteve-se as mesmas propriedades físicas para comparação, e avaliar os dois processos de fabricação. Na obtenção do mini motor, primeiramente procedeu-se de maneira alternativa com a utilização de ferro puro, bem como, na preparação dos pós de ferro (moagem e misturas), e assim fazendo a avaliação funcionamento do motor. Projetou-se a carga injetável e todos os parâmetros fazendo-se um levantamento por reologia de propriedades como viscosidade e tensão de cisalhamento. Também com DSC/TGA analisou-se os componentes da carga, termicamente, e estipulou-se as temperaturas de extração térmica e química. Após confecção dos corpos de prova levantou-se os dados elétricos e magnéticos. O material que apresentou melhor comportamento para fins de utilização em motores (alta resistividade, alta permeabilidade magnética), foi o injetado de FeNi50 desenvolvido, com resistividade média de 5,06*10-7 Ωm e baixas perdas por histerese magnética. Por fim construiuse o mini motor com FeNi50 a partir de cilindros injetados. O motor foi submetido a testes de acionamento. / This work was designed the core of a mini stepper motor, rotor and stator, obtained from the Powder Injection Molding (PIM) process. Magnetic, electrical and mechanical properties of the alloy obtained by the PIM process FeNi50 were evaluated. Also by conventional powder metallurgy gave the same physical properties for comparing and evaluating the two processes. Obtaining the miniature motor is held first alternative way with the use of pure iron as well as in the preparation of iron powders (grinding and mixtures thereof), thus making the evaluation of engine operation. Designed to charge injection and all the parameters by making a survey by rheological properties such as viscosity and shear stress. Also DSC / TGA was analyzed components of the load, heat, and it was stipulated temperatures of thermal and chemical extraction. After preparation of the specimens rose electric and magnetic data. The material showed the best behavior for the purpose of use in motors (high resistivity, high magnetic permeability), was injected FeNi50 developed, with an average resistivity of 5.06 * 10-7 Ωm and low loss magnetic hysteresis. Finally we constructed the mini motor with FeNi50 from injected cylinders. The engine underwent drive tests.
119

O uso da videoconferência via internet no auxílio ao projeto, assistido por computador, de moldes para peças de plástico injetadas /

Lencina, Diovani Castoldi January 1998 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T05:02:28Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T00:24:02Z : No. of bitstreams: 1 138034.pdf: 19125181 bytes, checksum: 7a73840fda8fc12abd91430d95731a0f (MD5)
120

Vibrador portátil para vazamento de gesso

Andrade, Pâmela Cândida Aires Ribas de 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T22:51:54Z (GMT). No. of bitstreams: 1 279304.pdf: 1211484 bytes, checksum: 7676c2e7e604389e18e926d70a3edc81 (MD5) / Vazamentos de modelo para confecção de prótese sobre implante podem alterar a posição do análogo, tendo como consequência problema de desajuste da prótese. A proposta do presente estudo foi testar um vibrador portátil para vazamento de gesso (desenvolvido para esse fim), comparando-o com outras técnicas de vazamento com vibradores convencionais. A partir de um modelo mestre com 2 implantes, 30 moldagens de transferência foram realizadas e divididas em três grupos: Grupo I (GI): vazamento feito em laboratório de prótese terceirizado, com vibrador convencional (10 modelos); Grupo II (GII): vazamento no laboratório da Universidade Federal de Santa Catarina, com vibrador convencional (10 modelos); Grupo III (GIII): vazamento com vibrador portátil fabricado para este estudo (10 modelos). A posição dos análogos e adaptação marginal da infraestrutura foram verificadas pelo teste do parafuso único no modelo mestre e subsequentes modelos de trabalho, e a mensuração do desajuste foi realizada por um microscópio de precisão e unidade analisadora Quadra-Check 200. Os dados foram analisados estatisticamente pela análise de variância (ANOVA) e teste Holm-Sidak (? = 0,05). Os valores médios (?m) foram (média±dp): GI: 19,19±4,73?m, GII: 21,72±5,41?m, GIII: 13,5±2,39?m, sendo estes os valores estatisticamente inferiores aos dois primeiros grupos. Dentro das condições deste estudo, foi possível concluir que a maior precisão dos modelos de trabalho foi conseguida quando se utilizou o vibrador portátil para vazamento dos moldes.