• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 235
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 239
  • 155
  • 84
  • 83
  • 77
  • 51
  • 42
  • 35
  • 34
  • 32
  • 31
  • 29
  • 29
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados

Munhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1 munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
142

Precisão das técnicas de moldagem para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)
143

Influência de técnicas de moldagem e de dois vazamentos na precisão dimensional de modelos de gesso e adaptação marginal de infraestruturas CAD/CAM em Y-TZP

Messias, Aion Mangino [UNESP] 18 March 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-18. Added 1 bitstream(s) on 2015-09-17T15:46:37Z : No. of bitstreams: 1 000846449.pdf: 793248 bytes, checksum: 4df424de74419794e88cc7fbcda6e98b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo objetivou analisar a exatidão de modelos de gesso, a partir de diferentes técnicas de moldagem e segundos vazamentos de gesso, bem como mensurar o desajuste marginal de infraestruturas de zircônia sobre preparos dentais reproduzidos nesses modelos. Um modelo mestre, com preparos para coroa total nos dentes 14, 16, 21 e 25, foi obtido e infraestruturas em zircônia CAD/CAM foram confeccionadas. Moldes totais com moldeira de estoque e silicone de adição foram obtidos a partir de três técnicas de moldagem (n=15): T1) mistura simultânea; T2) reembasamento - alívio com filme de PVC e T3) reembasamento - alívio com movimentação da moldeira. Foram aguardados 120 min para o 1º. vazamento de gesso (Tipo IV). O 2º. vazamento foi realizado 120 min após a remoção dos primeiros modelos. Para a mensuração da adaptação marginal das infraestruturas utilizou-se estereomicroscópio LEICA (50x). Para a análise da precisão dimensional linear, os modelos foram fotografados e, a partir de pontos pré-definidos, mensurações oclusais lineares latero-laterais (LL) e anteroposteriores, direita (APD) e esquerda (APE), foram realizadas (ImageJ). Mensurações das dimensões mésio-distais (MD) e vestíbulo-linguais (VL) dos preparos e da distância interpreparos do segmento 14-16 foram realizadas. Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independente do vazamento (1º ou 2º). Após 1º. vazamento, a técnica simultânea apresentou tendência a apresentar valores de desajuste menores do que as demais técnicas. Com exceção da dimensão MD do dente 21, a técnica simultânea produziu dimensões MD e VL similares ao modelo mestre. Não houve...(Resumo completo clicar acesso eletrônico abaixo) / This study conducted laboratory analysis of dental casts' accuracy obtained from different impression techniques and two castings, as well as measure the cervical marginal fit of zirconia infrastructures on dental preparations played in these models. Master model was used, with crown preparations in the teeth 14, 16, 21 and 25, on which zirconia infrastructures were made by CAD/CAM technology. For each impression technique full molds (n=15) were obtained by a single calibration operator with stock tray and polyvinylsiloxane: (T1) simultaneous mixture; (T2) reline - relief with PVC film and (T3) reline - relief with small movement of the tray. After mold removal, it was expected 120 min to realize the first pouring (type IV gypsum). The second pouring was made after 120 min from the removal of the first cast. To measure the marginal adaptation of infrastructure was used stereomicroscope LEICA (50x). For the analysis of linear dimensional accuracy, the models were photographed and, from pre-defined points, linear lateral-side occlusal measurements (LL) and anteroposterior, right (RPA) and left (EPA), were performed (ImageJ). Measurements of mesiodistal dimensions (MD) and bucco-lingual (VL) of the preparations and interpreparos distance segment 14-16 were performed. After verification of distribution and homocedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of the time of pouring (1º ou 2º). After 1st. pouring, the simultaneous technique tended to have lower misfit values than other techniques. Aside from tooth MD dimension 21 simultaneous technique produced dimensions MD and BL similar to the master model. No differences in inter-preparation linear dimensions and the occlusal line...(Complete abstract electronic access below)
144

Uma contribuição ao estudo das tensões residuais no fresamento

Norcino, Adriana Bruno [UNESP] 21 August 2013 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-21Bitstream added on 2014-12-02T11:20:56Z : No. of bitstreams: 1 000792987.pdf: 4111727 bytes, checksum: 017f0ba351e83931e66d4d3b81d00708 (MD5) / A usinagem de moldes e matrizes possui grande potencial de expansão e expressiva importância econômica. O processo de fresamento é amplamente empregado na confecção de cavidades de moldes e pode ser um substituto ao processo de eletroerosão (EDM), gerando superfícies com melhor integridade superficial. Sabe-se que as tensões residuais podem ser geradas nos processos de usinagem e são apontadas como uma das possíveis causas de falhas em componentes, tendo como agravante o fato de na maioria das vezes permanecerem como incógnita, desde a fabricação até a falha. Este trabalho mediu experimentalmente o campo, a magnitude, a profundidade e a direção das tensões residuais pelo Método do Furo-Cego, após o fresamento de acabamento do aço para moldes e matrizes VP100 com durezas diferentes obtidas por meio de tratamento térmico de têmpera. Os resultados foram correlacionados com a microdureza superficial da peça, microestrutura subsuperficial, pressão específica de corte e temperatura na interface cavaco-ferramenta. Os ensaios foram conduzidos em um centro de usinagem vertical CNC, com fresa  25 mm e dois insertos revestidos de TiNAl. Os resultados mostraram que as tensões residuais dependem dos parâmetros de corte empregados no fresamento, e por meio de simulação mostrou-se que o dispositivo de fixação não interferiu na geração de tensões residuais. O aumento do avanço tende a gerar tensões trativas em peças beneficiadas, ao passo que o incremento da velocidade de corte resulta em tensões compressivas em peças temperadas. A microdureza superficial da peça e a pressão específica de corte apresentaram relação inversa e não linear com a tensão residual. Grãos próximos à superfície fresada podem ser deformados pela ação mecânica da aresta de corte da ferramenta desde que tenham orientação preferencial com a das tensões principais máximas. / Machining of moulds and dies has a promising potential of expansion and expressive economic importance. The milling process is widely used in the manufacture of mold cavities and can be a substitute to the process of EDM (EDM) and generate surfaces with better surface integrity. Residual stress may be produced in machining processes and they are the main causes of failure in structural components. This research experimentally measured the field, magnitude, depth and orientation of residual stress by using Hole Drilling Method after finishing milling of VP100 steel for moulds and dies with distinct hardness. The results where correlated with part surface microhardness, subsurface microstructure, specific cutting energy and chip-tool interface temperature. The milling tests were carried out in a CNC machining center by using 25 mm diameter endmill with two TiNAl coated carbides. The results showed residual stresses depend on cutting parameters. Tensile stress is yielded in annealed parts as the tool feed increases, whereas compressive one is generated in quenched workpieces as the cutting speed grows. Part surface hardness and cutting specific pressure presented inverse non-linear relationship with residual stress. Grains near milled surface may be deformed by mechanical action of cutting tool edge since they have preferential orientation regarding to maximum principal stresses.
145

Desenvolvimento de concentrados de PVC reforçados com fibras de vidro longas (LF-PVC) para reforçar compostos de PVC rígido moldados por injeção / Development of long glass fiber PVC concentrate (LF-PVC)to reinforce injection molding rigid PVC compounds

Grizzo, Leandro Henrique 06 December 2013 (has links)
Made available in DSpace on 2016-06-02T19:10:23Z (GMT). No. of bitstreams: 1 6070.pdf: 6999498 bytes, checksum: 9bf7d2ee8c54baf0e933924f3696afe4 (MD5) Previous issue date: 2013-12-06 / Financiadora de Estudos e Projetos / This work presents a study and development of long glass fiber PVC pellet concentrate (LF-PVC) manufactured by extrusion similar wire coating technique to reinforce pelletized rigid PVC compounds to produce injection molding LF-PVC composites. The incorporation of LF-PVC in rigid PVC compound exhibited mechanical benefits mainly in tensile modulus, flexural modulus and notched impact strength. Injection molding LF-PVC composites with 20 wt% of fiberglass presented tensile and flexural modulus 90% higher than unreinforced rigid PVC; Izod and Charpy notched impact strength 13% and 40% higher than unreinforced rigid PVC, respectively. The reinforcement of rigid PVC with LF-PVC presented slight damage in heat distortion and Vicat temperatures. 20wt% fiberglass PVC composites presented around 10% lower than unreinforced rigid PVC because LF-PVC reinforcement presented little quantity of plasticizers and majority of low molecular weight PVC resin. The innovative technique developed by Grizzo in a preliminary work [1; 2] to incorporate long glass fiber in rigid PVC compound was optimized because the LF-PVC pellets produced presented lower quantity of plasticizer, adequate fiberglass roving with suitable coupling agent (sizing) for PVC and a fiberglass roving tex (g/km) with excellent cost. In summary the reinforcement of injection molding rigid PVC compound with LF-PVC compounds produced unsatisfactory mechanical performance of LF-PVC composites, although that allowed them to compete to long glass fiber polypropylene and polyamide composites in injection molding technical parts under room temperature. Also LF-PVC composites allowed improve usual PVC applications such as connections to reduce thickness or rise dimensional, for example diameter and length, which was not possible before. The last, there are potential applications for LF-PVC composites to be used in special pressurized connections to replace internal metallic reinforcement, and in faucets and other bathroom devices for metal replacement. / Neste trabalho é descrito o estudo e o desenvolvido de um composto granulado de PVC reforçado com fibras de vidro longas (LF-PVC), produzidos através de uma técnica de extrusão similar a de recobrimento de fios, para ser utilizado na fabricação de compósitos PVC/fibras de vidro moldados por injeção. A incorporação dos grânulos LF-PVC num composto de PVC rígido apresentou benefícios principalmente quanto à rigidez sob tração e flexão e à resistência ao impacto. O compósito de PVC reforçado com 20% em massa de fibras de vidro longas apresentou aumento de 90% nos valores de módulo de elasticidade sob tração e sob flexão, e um aumento de 13% e 40% na resistência ao impacto Izod e Charpy com entalhes, respectivamente. O reforçamento do composto de PVC rígido com os grânulos LF-PVC apresentou redução moderada nas temperaturas de deflexão térmica (HDT) e de amolecimento Vicat, sendo obtida uma redução de 10% para o compósito reforçado com 20% de fibras de vidro longas, em virtude da presença de uma pequena quantidade de plastificante e do uso de uma resina de baixa massa molar na formulação de PVC utilizada na fabricação do grânulo LF-PVC. A técnica inovadora de incorporação de fibras de vidro longas em compostos de PVC, desenvolvida por Grizzo em trabalho anterior [1; 2], foi aperfeiçoada através da redução da quantidade de plastificante utilizado no composto do grânulo LF-PVC; do uso de um roving de vidro com sizing específico para PVC; e do uso de um roving de vidro com um tex (g/km) de excelente custo. De um modo geral o reforçamento do composto de PVC rígido com os grânulos LFPVC apresentou desempenho mecânico considerado não satisfatório, porém com possibilidade dos compósitos PVC/fibras de vidro de competir com os compósitos de polipropileno e poliamida reforçados com fibras de vidro em peças técnicas moldadas por injeção sob condições normais de temperatura. O reforçamento também possibilita a melhoria de produtos convencionais de PVC, como conexões, através da redução de espessura e da ampliação de dimensionais, como diâmetros e comprimentos, não possíveis até o momento. Por fim, existe a possibilidade de uso dos compósitos PVC/fibras de vidro em conexões especiais, que apresentam alma metálica de reforço para suportarem elevadas pressões, e em torneiras e outros dispositivos sanitários que apresentem partes metálicas.
146

Influência do negro de fumo na absorção da radiação na região do infravermelho para o reaquecimento do copolímero de poli(tereftalato de etileno) - PET. / The influence of carbon black in the infrared absorption during the heating up of the polyethylene terephthalate.

Sofri, Fabio Lamon 06 August 2005 (has links)
Made available in DSpace on 2016-06-02T19:11:45Z (GMT). No. of bitstreams: 1 DissFLS.pdf: 2608700 bytes, checksum: 39ec6e4fcd10cd34a33b62178c4f4565 (MD5) Previous issue date: 2005-08-06 / The objective of this work was to study the influence of the use of carbon black as infrared absorber to improve the PET resin heat-up during the stretching blow molding of bottles. It was investigated the correlation between the main physical properties of the carbon blacks and the source setup conditions and the PET infrared absorption. Therefore, five carbon blacks with different physical characteristics were selected and mixed with a PET resin bottle grade by injection molding. The correlation between particle size, surface area and structure of carbon black and the optical properties, rheological behavior and heat-up of the compositions were studied. The rheological measurements showed that the carbon blacks did not modify the profile of the PET rheological curve; however both the viscosity and elasticity properties of the PET were dependent on the carbon black particle size and structure. The differential scanning calorimetry (DSC) results showed that the carbon black particles modified the PET crystallization kinetics by increasing the induced crystallization temperature during the cooling step. Through the L* a* b* color measurements, it was verified that the L* color was indirectly proportional to the carbon black content. Finally, the heat-up performance was investigated using two methods: (a) the surface temperature measurement of samples heated under infrared lamps and, (b) the total absorption of each composition calculated using the spectrum data obtained by near infrared spectroscopy (NIRS). Using the scanning electron microscopy (SEM) it was verified that the carbon black content did not modify significantly the morphological aspect and the fracture surface of the compositions. / O objetivo deste trabalho foi estudar a tecnologia de utilização do negro de fumo como absorvedor de radiação infravermelha para o reaquecimento da resina PET durante o ciclo de sopro de garrafas. Foi investigada a correlação entre as principais características físicas do negro de fumo e as condições de operação da fonte de radiação empregada no reaquecimento, e o fenômeno de absorção da radiação infravermelha da resina PET. Para tal, foram selecionados cinco tipos de negro de fumo com características físicas diferentes, e incorporados em uma resina PET grau garrafa, através da moldagem por injeção. Foi estudada a correlação entre o tamanho de partícula primária, área superficial e estrutura do negro de fumo, e as características óticas, o comportamento reológico, e o reaquecimento das composições. As medidas reológicas mostraram que a incorporação de baixos teores de negro de fumo não modificou o perfil da curva reológica do PET; contudo, a viscosidade e a elasticidade foram dependentes do tamanho de partícula e da estrutura do negro de fumo. Os resultados de calorimetria exploratória diferencial (DSC) mostraram que as partículas de negro de fumo atuaram como nucleantes e modificaram a cinética de cristalização do PET, aumentando a temperatura de indução cristalina no resfriamento. Através das medidas de cor L* a* b*, verificou-se que o teor de negro de fumo e cor L* são inversamente proporcionais. Finalmente, a performance de reaquecimento foi investigada por duas metodologias: (a) medidas de temperatura na superfície dos corpos de prova reaquecido sob painel de lâmpadas infravermelhas e, (b) cálculo da absortividade total ) (a das composições a partir da espectroscopia na região do infravermelho próximo (NIR). Utilizando a microscopia eletrônica de varredura (MEV) pode-se observar que a presença de baixos teores de negro de fumo não alterou, significativamente, o aspecto da morfologia e a superfície de fratura das composições.
147

Reatividade de materiais de moldagem na fundição de precisão de titânio / Reactivity of materials molding for titanium investment casting

Oliveira, Diego Pedreira de 13 April 2009 (has links)
Made available in DSpace on 2016-06-02T19:12:01Z (GMT). No. of bitstreams: 1 3036.pdf: 14240983 bytes, checksum: ee6c8c44e8b6ec5c94280d7b7d936f6b (MD5) Previous issue date: 2009-04-13 / Financiadora de Estudos e Projetos / Investment casting of Titanium parts free of defects is very difficult owing to the reactivity of this element in the liquid state .The objective of this study was to evaluate the reactivity of titanium with refractory oxides of high thermodynamic stability, such as yttria and alumina. Centrifugal castings of small parts were carried out by melting the metal in an yttria coated crucible and pouring the liquid into molds coated with a mixture of yttrium and aluminum oxides. As binder for the powders were added colloidal suspensions of silica, alumina, yttria or zirconium acetate. Only the silica and alumina colloidal bonded the moulds with useful mechanical strength allowing the centrifugal casting trials. Both, yttria colloidal and zirconium acetate were excluded of the trials. By analyzing the hardness profile it could be noted that a similar curve was obtained for different moulds (oxides plus binder) related to the hardened layer thickness. However, the molds using a higher thermodynamic stability combination of binder and oxides presented lower Vicker values. The pair Yttria/Alumina colloidal induced less than 350 Vickers and Alumina/Alumina colloidal less than 720 Vickers on the surface of titanium as cast, for instance. Finally, a mathematical simulation of the process was proposed and it could be well adjusted and compared to the experimental graphics. / A obtenção de peças de titânio pelo processo de fundição de precisão, livre de defeitos, é extremamente complicada devido à elevada reatividade do titânio no estado líquido com os constituintes do molde, os óxidos cerâmicos. Este trabalho objetivou estudar a reatividade do titânio com óxidos de alta estabilidade termodinâmica, a saber: de alumínio e de ítrio. Foram realizadas tentativas de fundição centrífuga de pequenas peças utilizando cadinhos revestidos com ítria e vazamento sobre moldes revestidos majoritariamente com os óxidos citados. Como aglomerantes destes pós refratários foram utilizadas suspensões coloidais de sílica, de alumina e de ítria além de acetato de zircônio. Os dois últimos não proporcionaram aos moldes resistência mecânica suficiente para serem trabalhados, sendo excluídos dos testes de fundição. Com os aglomerantes à base de sílica e alumina foram então construídos os moldes nos quais foi vazado o titânio (comercialmente puro) por fundição centrífuga. Através de perfis de microdureza Vickers verificou-se um comportamento similar das combinações de aglomerante mais refratário no que tange a espessura da camada alfa endurecida. No entanto, as combinações de maior estabilidade termodinâmica apresentaram menores valores de microdureza na superfície das amostras, com o par ítria/alumina apresentando resultados abaixo de 350 Vickers e o par alumina/alumina cerca de 720 Vickers na superfície de contato com o molde. Ao final, foi proposta uma simulação matemática do processo gerando gráficos teóricos que puderam ser bem ajustados aos gráficos experimentais.
148

Análise da influência das condições de processamento na morfologia e nas propriedades de blendas poliméricas PBT/ABS moldadas por injeção

Cardinali, Daniel Albuquerque 29 June 2011 (has links)
Made available in DSpace on 2016-06-02T19:12:10Z (GMT). No. of bitstreams: 1 3720.pdf: 10000325 bytes, checksum: 03a0dbf8e4a20c3719f74d02199a00c5 (MD5) Previous issue date: 2011-06-29 / Universidade Federal de Minas Gerais / A study on the correlation of blend morphology, properties, the injection molding process and manufacturing methods of polymeric blends constituted of PBT and ABS was proposed. Thus, uncompatibilized PBT/ABS blends have been prepared in a twin-screw extruder using different parameters of process, in order to obtain blends presenting distinct properties and, if possible, distinct morphologies. The extruded blends have been eventually submitted to the injection molding process for the evaluation of the influence of the injection molding process parameters on the morphology, thermal properties and mechanical properties, especially impact strength, of PBT/ABS blends. The following parameters of the injection molding process and its influence on the properties mentioned above have been studied: injection temperature, mold temperature, holding pressure and injection speed. The Design of Experiments approach has been used to arrange the full set of experiments and also to statistically analyze the results. The morphology of the extruded and injection molded blends has been investigated by Transmission Electron Microscopy, the mechanical properties by Izod impact strength tests and the degradation of the blends constituents has also been evaluated. The results have indicated that major differences on the impact strength of the samples can be achieved by only varying the injection molding parameters. Furthermore, mold temperature and injection speed have significantly affected the impact strength and the ductile-brittle transition temperature of the injection molded samples. Morphological analyses and degradation studies have suggested that the dispersion degree of the ABS disperse phase particles within the PBT matrix plays an essential role in determining the impact strength of the blends. / Foi realizado o estudo de correlação entre as condições de preparação e moldagem de blendas poliméricas constituídas de PBT e ABS, e a sua morfologia e suas propriedades. Para tal, blendas PBT/ABS foram preparadas em extrusora de rosca dupla, sem o uso de um agente compatibilizante e utilizando-se diferentes parâmetros de processo, visando a obtenção de blendas com morfologias distintas e, possivelmente, propriedades também distintas. As blendas obtidas por extrusão foram posteriormente submetidas ao processo de moldagem por injeção para avaliação da influência dos parâmetros deste processo sobre a morfologia, propriedades térmicas e propriedades mecânicas, especialmente resistência ao impacto, das blendas PBT/ABS. Os seguintes parâmetros do processo de moldagem por injeção e os seus efeitos nas propriedades citadas anteriormente foram estudados: velocidade de injeção, pressão de recalque, temperatura de injeção e temperatura do molde. Técnicas de DOE Design of Experiments foram utilizadas como ferramenta auxiliar para elaboração do planejamento experimental e também no tratamento estatístico dos resultados obtidos. As morfologias das misturas obtidas, após os processos de extrusão e injeção, foram analisadas através de microscopia eletrônica de transmissão, as propriedades mecânicas através de ensaios de resistência ao impacto e a degradação dos constituintes das blendas, por viscosimetria de soluções diluídas e espectroscopia no infravermelho, também foi avaliada. Os resultados mostram que grandes variações na resistência ao impacto podem ser obtidas apenas alterando-se os parâmetros da moldagem por injeção. A temperatura do molde e a velocidade de injeção influenciaram significativamente na resistência ao impacto e na temperatura de transição dúctil-frágil das amostras. As análises morfológicas e de degradação sugerem que o grau de dispersão das partículas de ABS na matriz de PBT é o principal responsável pela definição da resistência ao impacto das blendas.
149

Caracterização estrutural e monitoramento ótico da cristalização de nanocompósitos de polietileno de alta densidade com partículas de diferentes geometrias durante a moldagem por injeção / Structural characterization and optical monitoring of the crystallization of high density polyethylene nanocomposites with different particles during injection molding

Beatrice, Cesar Augusto Gonçalves 06 March 2014 (has links)
Submitted by Regina Correa (rehecorrea@gmail.com) on 2016-09-21T19:44:59Z No. of bitstreams: 1 TeseCAGB.pdf: 10087704 bytes, checksum: 203cfdf80de46b4f1859956502b03897 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-23T18:37:46Z (GMT) No. of bitstreams: 1 TeseCAGB.pdf: 10087704 bytes, checksum: 203cfdf80de46b4f1859956502b03897 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-23T18:37:54Z (GMT) No. of bitstreams: 1 TeseCAGB.pdf: 10087704 bytes, checksum: 203cfdf80de46b4f1859956502b03897 (MD5) / Made available in DSpace on 2016-09-23T18:38:00Z (GMT). No. of bitstreams: 1 TeseCAGB.pdf: 10087704 bytes, checksum: 203cfdf80de46b4f1859956502b03897 (MD5) Previous issue date: 2014-03-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / The main objectives of this project were to study the morphology, the crystallization kinetics and to monitor on-line the crystallization during the injection molding process using an optical system of nanocomposites of high density polyethylene (HDPE) with three different inorganic particles: montmorillonite nanoclay, halloysite nanotubes and faujasite type zeolite. The optical system allowed analyzing the crystallization process by the changes of the optical properties during the solidification of the materials. The nanocomposites were prepared by melt intercalation in a twin-screw extruder. The resultant structures were characterized by transmission electron microscopy (TEM) and rheological properties. The extruded nanocomposites developed intercalated and well distributed structures. Crystallization kinetics studies were done by differential scanning calorimetry (DSC) and rheological measurements. It was concluded that the nanoparticles in quiescent conditions accelerated the overall crystallization of HDPE, acting as nucleating agents. The nucleating effect of these particles was predominant over the HDPE crystallization and they also modified the nucleation mechanism and the crystal morphology in some conditions. From the studies of flow induced crystallization, it was observed again that the nanoparticles accelerated the crystal growth rate. In this case it was attributed to the weak forces between the polymer chains and the surface of the nanoparticles. Finally, the nanocomposites’ crystallization was monitored during the injection molding process. The optical system showed that the nanoparticles accelerated the crystallization of HDPE; the optical results were correlated with the morphology of the injection molded samples. / Neste projeto estudou-se a morfologia e a cinética de cristalização quiescente e induzida por fluxo de nanocompósitos de polietileno de alta densidade (HDPE) contendo nanocargas com diferentes geometrias: nanotubos de haloisita, lamelas de montmorilonita e nanocubos de zeólita do tipo faujasita. Utilizando-se um teor de nanocarga fixo e avaliando-se, em menor escala, a influência da presença ou não de tratamento orgânico superficial, nanocompósitos posteriormente preparados em uma extrusora de rosca dupla corrotacional foram caracterizados por microscopia eletrônica de transmissão (MET), calorimetria exploratória diferencial (DSC) e propriedades reológicas. Em seguida, estes nanocompósitos foram injetados em diferentes condições de processamento, variando- se a vazão de injeção, a temperatura do molde e a pressão de empacotamento; ao mesmo tempo em que a cinética de cristalização foi monitorada “on-line” através de um sistema ótico que permitiu a análise da cinética de cristalização através das mudanças de propriedades óticas desses materiais durante a solidificação. Após a moldagem por injeção, as amostras foram caracterizadas. Observou-se que as nanopartículas, em condições quiescentes, aceleraram a cristalização global do HDPE, agindo como agentes de nucleação, e modificaram também o mecanismo de nucleação e a morfologia dos cristais. Sob a presença de fluxos cisalhantes, as nanocargas também mostraram uma tendência em antecipar a formação de núcleos, através da orientação molecular, uma vez que as interações entre os componentes dos nanocompósitos foram bastante fracas. O sistema ótico, por sua vez, permitiu concluir o efeito acelerador da cristalização global das nanopartículas, e as posteriores análises de difração de raios-x de baixo ângulo (SAXS) permitiram observar as diferentes orientações preferenciais das lamelas cristalinas em função dos parâmetros de injeção e da influência das nanopartículas.
150

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four / In vitro analysis of the accuracy of splinting impression techniques using all-on-four system

Pimentel, Gustavo Henrique Diniz [UNESP] 15 October 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5) / O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)

Page generated in 0.0534 seconds