• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 144
  • 58
  • 8
  • 6
  • Tagged with
  • 316
  • 316
  • 160
  • 158
  • 146
  • 144
  • 78
  • 65
  • 63
  • 58
  • 54
  • 53
  • 52
  • 51
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Risk Factors Contributing to Urinary Tract Infections (UTI) in Neonates

Harshman, Jennifer V 01 January 2022 (has links)
Urinary tract infections (UTI) in neonates are caused by many types of risk factors such as increased length of maternal labor, physiologic maternal conditions, prematurity, and decreased birth weight. Identification of potential risk factors for UTI in neonates can lead to rapid assessment and early interventions to treat urinary infection in the neonate before it transitions to a severe or life-threatening condition, such as a kidney infection or septicemia. The primary purpose of this literature review was to examine risk factors predisposing neonates to UTI. The secondary purpose was to identify if length of time to drug therapy used to treat UTI in neonates decreased complications and recurrence in the preterm infant. A comprehensive literature review was performed using research articles available from 2007 to 2021 regarding the factors influencing the occurrence of urinary tract infections in neonates. Databases used to search for articles include EBSCOhost databases, Medical Literature On-Line (Medline), Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Google Scholar. Searches used a combination of the following terms: ‘UTI’, OR ‘urinary tract infection’, AND ‘neonates’, OR ‘infants’, ‘risk factors’. Of the articles reviewed, 15 met the inclusion criteria and answered the research questions. Two studies showed circumcision in male infants increases the risk of urinary tract infection in infants. Two studies revealed vesicourethral reflux in female infants compared to male infants increases the risk of UTIs. One article suggested women with longer labor (>24 hours) from onset had an increased likelihood of the newborn having a UTI within the first week of life. Preliminary data suggests there are significant precursors and risk factors that can be identified to diagnosis UTIs early and having them treated promptly. All the reviewed articles focused on collection of urine samples within hours of birth and physiologic findings of a UTI can decrease the length of stay and costs related to infection treatment. Antibiotic therapy being administered empirically due to rapid assessment of risk factors for UTI in the neonate decreases time to treatment by three to five days, which improves health outcomes. Rapid assessment and diagnosis of UTI is of value for preventable measures to be ordered sooner to avoid repeat and resistant UTIs in the neonate.
152

The Effect of Income Level on the Relationship Between the Personal Support Matrix and Sustained Breastfeeding

Gossler, Sandra Mann 01 January 2007 (has links)
The Healthy People 2010 Objectives for the population of the United States include the objective for women to sustain breastfeeding at a higher rate than they are currently.The American Academy of Pediatrics (AAP) now recommends that all infants be fed human milk for the first year of life instead of the previously recommended first six months of life. Breastfeeding initiation rates are rising, but breastfeeding duration rates continue to fall. It was hypothesized that the support system of the women may play a role in the duration of breastfeeding. The purpose of this research study was to investigate the support system and breastfeeding rates of mothers during the first six weeks after delivery and to determine if income level had an effect on these systems and rates. Mothers were interviewed during their hospitalization for childbirth regarding their perception of their support system currently in place. A questionnaire was administered regarding support from friends, family members, co-workers, and health care professionals and the responses were quantified. Mothers were contacted weekly to determine if breastfeeding was being sustained and who was the most supportive person to them. At the end of six weeks or when breastfeeding was discontinued, the mothers were interviewed a second time to determine if the support system had changed. The results of this study showed that income level affected the duration of breastfeeding and the mother's perception of her support system. Additionally, the results showed that the evaluation of the support system changed only slightly over time. The results showed preliminary ability of the study tool to predict breastfeeding at six weeks by income.This document was created using Microsoft Word 2003. The statistical package used for data analysis was JMP version 6.
153

Avaliação do processo de identificação do neonato de um hospital privado / Evaluation of the identification procedure for newborns in a private hospital

Quadrado, Ellen Regina Sevilla 09 June 2011 (has links)
Trata-se de um estudo exploratório, descritivo de abordagem quantitativa, que teve por objetivo avaliar o processo de identificação do neonato admitido na unidade de terapia intensiva neonatal e semi-intensiva de um hospital privado no Município de São Paulo. A casuística compôs-se de 540 oportunidades de análise, selecionadas pela amostragem probabilística aleatória simples. A coleta de dados ocorreu no período de maio a agosto de 2010, por meio de um formulário, contendo as três etapas do processo de identificação: componentes de identificação, condições da pulseira e quantitativo de pulseiras. Os dados foram analisados em função da estatística descritiva, e sendo aplicado o teste estatístico com significância de 5%. No que diz respeito ao desempenho geral do processo, o percentual de conformidade foi de 82,2%. No que tange as três etapas integrantes do processo, o maior índice de conformidade (93%) foi atribuído a segunda etapa e o menor (89,3%) a terceira etapa, com diferença estatística significante (p=0,046). Em relação a primeira etapa, a presença do código de internação obteve (98,5%) de conformidade; na segunda,o melhor percentual (99,8%), foi atribuído à confecção correta da pulseira e na terceira, houve (88,5%) de conformidade para o grupo de neonatos em condições especiais, não apresentando diferença estatística significante p=0,895. Acredita-se que os achados deste estudo subsidiem as reestruturações necessárias no processo de identificação dos recém-nascidos e o estabelecimento de metas assistenciais e gerenciais, para a melhoria contínua da qualidade e da segurança dos pacientes. / This is an exploratory, descriptive study of quantitative approach, aiming to evaluate the identification procedure for newborns admitted to a neonatal intensive and semi-intensive care unit of a private hospital in the city of São Paulo. The sample consisted of 540 opportunities for analysis, selected by the simple random probability sampling. Data collection occurred between May and August 2010, using a form containing the three phases of the identification procedure: identification components, conditions of ID bracelet and quantitative of ID bracelets. Data were analyzed according to descriptive statistics and the statistical test was applied with a significance of 5%. Regarding performance of the general process, the percentage of compliance was 82.2%. Regarding the three phases of the process, the highest compliance rate (93%) was related to the second phase and the lowest (89.3%) to the third phase, with a statistically significant difference (p = 0.046). Regarding the first phase, the presence of a hospitalization code obtained (98.5%) of compliance, in the second, the best percentage (99.8%) was attributed to correct manufacturing of the ID bracelet and third, with (88, 5%) of compliance for the group of newborns under special conditions, showing no statistically significant difference p = 0.895. It is believed that the findings of this study will subsidize the necessary reorganization of newborn identification procedure and establishment of assistance and management of goals for the constant improvement of quality and patient safety.
154

O impacto de um curso de atualização no conhecimento de enfermeiros sobre o ambiente sensorial nas unidades neonatais / The impact of an online updating course on nurses\' knowledge of sensory environment in neonatal units

Castro, Fernanda Salim Ferreira de 05 February 2018 (has links)
Na atualidade, a educação permanente do enfermeiro pode ser potencializada se oferecida online, em especial, numa temática em que há escassez de conhecimento e materiais educativos. Assim, sentimo-nos motivadas em oferecer um curso pela internet que seja capaz de atualizar enfermeiros de unidades neonatais sobre o ambiente sensorial de bebês pré-termo. O estudo teve como objetivos descrever o processo de desenvolvimento de um curso de atualização online junto aos enfermeiros acerca do ambiente sensorial da unidade neonatal com enfoque no ruído, manipulação e luminosidade e avaliar a aprendizagem cognitiva do enfermeiro neonatal no curso de atualização online. O projeto foi desenvolvido em duas fases: 1 - desenvolvimento do curso de atualização online; 2 - avaliação da aprendizagem cognitiva influenciada pelo curso. A fase 1 tratou-se de um estudo metodológico no qual foi desenvolvido um curso de atualização online com duração total de 30 horas, disponibilizado em um ambiente virtual de aprendizagem e contou com o auxílio de tecnologias educacionais digitais. A fase 2 foi realizada por meio de uma pesquisa quase-experimental envolvendo intervenção educacional (curso desenvolvido) e avaliação de pré e pós-teste para comparação de desempenho cognitivo dos participantes sob influência do curso online. Foram convidados a participar do estudo enfermeiros que trabalham nas Unidades de Cuidado Intermediário Neonatal (UCIN) e Unidade de Terapia Intensiva Neonatal (UTIN) do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (HCFMRP/USP) e UCIN do Centro de Referência em Saúde da Mulher de Ribeirão Preto - MATER. A coleta de dados ocorreu no período de 11/09/2017 a 02/10/2017. Utilizou-se análise descritiva com apresentação de frequências para os dados qualitativos e média, mediana e desvio padrão para as variáveis quantitativas. Para análise de impacto do curso na aprendizagem dos 22 enfermeiros participantes utilizou-se o teste estatístico não paramétrico de Wilcoxon. A avaliação de desempenho foi realizada a partir da diferença entre a pontuação obtida pelo participante no pós-teste em relação à pontuação do pré-teste. Os dados foram tabulados e testados através do programa SPSS 18 e o nível de significância nas análises foi de 5%. A diferença entre o pos e pré-teste, para a avaliação do conhecimento cognitivo proporcionado pelo curso de atualização, resultou em p<0,001, demonstrando que houve diferença estatísticamente significante e que, portanto, houve aprendizagem cognitiva dos enfermeiros que participaram do curso de atualização online auxiliado pelas tecnologias educacionais digitais / Currently, nurses\' continuing education can be enriched if offered online, especially in subjects lacking knowledge and educational tools. Therefore, we were motivated to offer an online course that would be able to update nurses of neonatal units on the sensory environment of preterm infants. The aims of the study were: to describe the process of developing an online update course with nurses about the sensory environment of the neonatal unit focusing on noise, manipulation and luminosity and to evaluate the cognitive learning of neonatal nurses after the online update course. The study had two phases: 1 - development of the online update course; 2 - evaluation of the cognitive learning generated by the course. Phase 1 was a methodological study in which a 30 hours online update course was created with the incorporation of digital educational technologies and made available in a virtual learning platform. Phase 2 was performed through a quasi-experimental methodology involving educational intervention through the online course and a pre and post cognitive performance test to evaluate participants\' progress due to the online course. Nurses working at the Neonatal Intermediate Care Unit and the Neonatal Intensive Care Unit of the Hospital das Clínicas of the Faculty of Medicine of Ribeirão Preto of the University of São Paulo and the Neonatal Intermediate Care Units of the Reference Center on Women\'s Health of Ribeirão Preto - MATER. Data collection was from 9/11/2017 to 10/2/2017. Descriptive analysis with frequency distribution was used for the qualitative data and mean, median and standard deviation for the quantitative variables. Wilcoxon nonparametric statistical test was used in the analysis of the course learning impact and in the intra-group comparisons to assess the acquired cognitive knowledge of the 22 enrolled nurses. The performance evaluation was based on the difference between the score obtained in the post-test and the pre-test. The data were tabulated and tested with SPSS 18 and the level of significance was set at 5%. The evaluation of the cognitive knowledge provided by the update course measured by the difference between the pos and pretest was statistically significant difference (p<0.001). Therefore, the update online course with digital educational technologies was able to generate cognitive learning by nurses enrolled
155

Incidência e fatores de risco de remoção por suspeita de infecção de corrente sanguínea associada ao cateter central de inserção periférica em uma coorte de neonatos / Incidence and risk factors of removal due to suspected catheter-associated bloodstream infection of Peripherally Inserted Central Catheter in a cohort of neonates.

Magalhães, Talita Elci de Castro 26 July 2013 (has links)
Introdução: o cateter central de inserção periférica (CCIP) tornou-se amplamente utilizado nas unidades de terapia intensiva neonatal (UTIN) na última década em razão da facilidade de sua instalação, permitindo a infusão de soluções endovenosas vesicantes, irritantes, hiperosmolares e de longa duração em veias centrais. Uma das complicações mais temidas relacionadas ao uso do CCIP é infecção de corrente sanguínea associada ao cateter cujo diagnóstico se confirma somente após a sua remoção, com o resultado de cultura da ponta do dispositivo e o resultado de hemocultura periférica do neonato. Objetivo: determinar a incidência de remoção por suspeita de infecção de corrente sanguínea relacionada ao CCIP e identificar os seus fatores de risco. Metodologia: coorte prospectiva composta por neonatos com CCIP internados em uma Unidade de Terapia Intensiva Neonatal de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 30 de agosto de 2012. As variáveis de exposição analisadas foram às relacionadas às características demográficas e clinicas dos neonatos, procedimentos relacionados à inserção do cateter, tipo de terapia intravenosa infundida pelo CCIP e o tempo de permanência do cateter. O desfecho analisado foi o motivo de remoção do cateter - eletivo ou por suspeita de infecção. Os dados obtidos de registros de prontuário foram armazenados em planilha Microsoft Excel 2010® e analisados com o software Stata 11,1. Foram determinadas medidas de tendência central e dispersão para as variáveis contínuas e frequências absolutas e relativas para as variáveis nominais. A existência de associação entre as variáveis de exposição e desfecho foi determinada pelo teste Qui-quadrado (teste 2), exato de Fisher e t Student. As variáveis com valor p < 0,05 foram incluídas na análise multivariada com regressão de Poisson. O nível de significância estatística adotado foi p < 0,05 com intervalo de confiança de 95%. O projeto de pesquisa foi aprovado pelo Comitê de Ética e Pesquisa da instituição campo do estudo. Resultados: A coorte inicial foi composta por 551 neonatos com CCIP e atenderam os critérios de elegibilidade, 401. A incidência de remoção por suspeita de infecção associada ao cateter foi 13,7%. A média de permanência de cateteres removidos por suspeita de infecção foi de 16,4 dias e dos removidos eletivamente, 11,7 dias, valor p=0,0001. Os fatores de risco para remoção por suspeita de infecção foram os diagnósticos de distúrbio hidroeletrolítico, RR 3.04. IC95%[1,727-5,054], valor p = 0,000 e apnéia, RR 2,38, IC95% [1,105-4,564], valor p = 0,016. As variáveis, média da idade gestacional corrigida superior a 32 semanas, RR 0,893, IC95% [0,832-0,956], valor p = 0,002 e o uso de cateter monolúmen de silicone, RR 0,278, IC95% [0,128-0,536], valor p = 0,000 se configuraram como fatores de proteção para remoção por suspeita de infecção associada ao CCIP. Dos 72 cateteres removidos por suspeita de infecção, 3 (4,2%)apresentaram confirmação de infecção do cateter. Conclusão: Os resultados sugerem que os diagnósticos identificados como fatores de risco devem ser incluídos no protocolo assistencial como fatores preditores de remoção por suspeita de infecção. Estes recém-nascidos necessitam ser especialmente monitorados em busca de sinais de infecção. Além disso, a escolha do tipo de dispositivo CCIP deve ser objeto de mais investigações, bem como os critérios de decisão para remoção do CCIP, por suspeita de infecção, tendo em vista a reduzida frequência de confirmação de infecção entre os cateteres removidos por suspeita. / Introduction: The peripherally inserted central catheter (PICC line) has become widely used in the neonatal intensive care units (NICU) in the last decades due to its ease installation and to allow infusion of vesicant, irritant and hiperosmolar solutions by long period in central veins. One of the most feared complications related to the use of PICC lines is the catheter associated bloodstream infection, which is confirmed after its removal with the result of catheter\'s tip culture and the results of neonate peripheral blood culture. Objective: to determine the incidence of removal due to PICC-line associated bloodstream infection and identify its risk factors. Methods: a prospective cohort of neonates with PICC line hospitalized in a NICU of a private hospital of the city of São Paulo. Data were collected from August 31st, 2010 to August 30th, 2012. The independent variables analyzed were related to demographic and clinical characteristics of newborns, procedures related to insertion of catheter, type of intravenous therapy infused and the catheter dwell time. The outcome variable analyzed was the reason for catheter removal elective or due to PICC-line suspected bloodstream infection. Data were obtained from the medical charts and stored in Microsoft Excel 2010 ® spreadsheet. Statistics analysis was conducted in the software Stata 11.1®. The continuous variables were showed by central and dispersion tendency measures and for qualitative variables, the data were showed by absolute and relative frequencies. The association between independent and outcome variables was determined by chi-square test (2), Fisher exact and t Student. Variables with p <0.05 were included in Poisson multivariate regression model. The level of statistical significance adopted was p<0.05 with a confidence interval of 95%. The research project was approved by the Ethics and Research Committee of the hospital where the study was carried out. Results: the initial cohort was composed of 551 neonates with PICC-line and 401 met the eligibility criteria. The incidence of suspected catheter associated bloodstream infection removal was 13.7%. The mean dwell time of PICC removed due suspicious of infection was 16,4 days and due to elective removal was 11,7 days, p value=0,0001. The risk factors for catheter-associated bloodstream infection identified were the diagnosis of hydroelectrolytic disorder, RR 3.04, CI95% [1.727 - 5.054], p value= 0.000 and diagnose of apnea, RR 2.38, CI95% [1.105 - 4.564], p value=0.016. The variables identified as protective factors for removal due suspected infection were: corrected gestational age of more than 32 weeks, RR 0.893, CI95% [0.832 - 0.956], p value=0.002 and single-lumen silicone catheter, RR 0.278, CI95% [0.128 - 0.536], p value= 0.000. From 72 catheters removed due to PICC-line suspicious of bloodstream infection, the infection was confirmed only to 3 (4.2%)of them. Conclusion: The results suggested that the diagnosis identified as risk factors should be included in the protocol of PICC lines management as predictors for removal due to suspected of infection. These neonates need to be carefully monitored for signs of infection. Moreover, choosing the most appropriate type of PICC should be further investigated, as well as the criteria to support the decision of removing the catheter considering the low number of confirmed catheter-associated infection.
156

Reatividade do prematuro aos cuidados de rotina em uma Unidade de Terapia Intensiva Neonatal / Reactivity of prematures during manipulation in a Neonatal Intensive Care Unit

Velozo, Ana Beatriz Ferreira 30 November 2018 (has links)
Considerando-se que as experiências não dolorosas também causam desequilíbrio em recém nascidos pré-termo (RNPT) e eventos físicos, psicológicos e sociais que resultam em reações excessivas e dificuldade de enfrentamento, são geradores de estresse, fazazendo-se necessário estudar as reações dos prematuros a essas situações não dolorosas e habituais em Unidade de Terapia Intensiva Neonatal (UTIN). O estudo teve como objetivo: Avaliar a reatividade do RNPT aos cuidados de rotina em uma UTIN. Trata-se de estudo observacional, descritivo, exploratório. A amostra foi constituída por 17 RNPT, internados na UTIN, de um hospital do interior paulista, cujas mães ou responsável aceitaram a participação dos mesmos na pesquisa. Após a aprovação pelos Comitês de Ética em Pesquisa iniciou-se a coleta de dados, sendo os dados de caracterizações maternas e neonatais coletados dos prontuários e os relacionados aos procedimentos de rotina (banho, cuidado agrupado para a higiene e conforto e exame físico médico) e reatividade dos RNPT, coletados a partir das filmagens para posterior análise. Os parâmetros fisiológicos (FC e SatO²) foram registrados minuto a minuto, durante os períodos: basal, manipulação e recuperação. A mímica facial, foi avaliada nos períodos: basal, recuperação 1 e 2 e as Atividades Corporais e Estados de Sono e vigília, nos períodos: basal, de manipulação e recuperação. Para as FC e SatO², foi utilizado o teste estatístico de Wilcoxon para comparar se houve variação significativa entre os períodos, com nível de significância de 5%. A reatividade comportamental dos RNPT foi avaliada através das proporções das atividades faciais e através da distribuição de frequência e de porcentagem dos estados de sono e vigília e movimentação corporal, possibilitando a descrição das mais frequentes em cada um dos períodos avaliados nos diferentes cuidados de rotina dos RNPT. No Banho as medianas das FC variaram entre os períodos: basal, manipulação e recuperação, sendo respectivamente de: 151,5, 152,9 e 149,2 bpm. Os valores medianos para a SatO² foram: 97,2% 98,1% e 97,9% na mesma sequência. Não houve diferença estatística entre os períodos avaliados para estas variáveis. No cuidado agrupado as medianas das FC variaram entre os períodos sendo: 159,1, 158 e 157,5 respectivamente. Houve diferença estatisticamente significante para a FC entre os períodos basal e de recuperação, com p<0,05 (0,047). Para a SatO², os valores medianos foram: 97%; 97% e 97,1% respectivamente. Não houve diferença estatística entre os períodos analisados para esta variável. No exame físico médico as medianas das FC variaram entre: 153,5, 153,8 e 153,8 bpm nos períodos. Os valores medianos para a SatO² foram: 98,4%, 98% e 97,8%, na mesma sequência. Não houve diferença estatística entre os períodos avaliados para estas variáveis. No banho os valores proporcionais medianos da mímica facial variaram entre: 16,7%, 20%, e zero respectivamente nos períodos basal, Recuperação 1 e 2. No cuidado agrupado os valores foram: zero, 20% e 10%. Zero, 2,5% e zero, foram os valores nos respectivos períodos no exame físico médico. Não houve muita variação na freqüência das atividades Corporais nem nas freqüências dos estados de Sono e Vigília entre os períodos avaliados nos diferentes cuidados avaliados, sendo que prevaleceram movimentos regulares, pequenos, relaxado (AC1) e o estado de sono ativo, exceto no período de manipulação no banho, que prevaleceu o choro. Embora as avaliações tenham se dado nos cuidados de rotina, houve presença de 5,9% de aspiração de VAS, considerada por alguns autores como um procedimento doloroso. Os resultados apontaram ainda o uso da sacarose em 3 (17,6%) cuidados agrupados para a higiene e conforto. Mostrase necessária a revisão da aplicação protocolo do uso dessa solução na instituição para que esta não seja oferecida indiscriminadamente em situações que não envolvam procedimentos dolorosos. Sinalizamos a necessidade de rever alguns procedimentos de rotina aplicados nos RNPT, visando à diminuição do estresse por eles vivenciado / Considering that non-painful experiences also cause imbalance in preterm newborns (PTNB) and that physical, psychological and social events which result in excessive reactions and difficulty in coping are also stressing factors for them, it is necessary to study the reactions of premature infants to these non-painful and habitual situations in Neonatal Intensive Care Unit (NICU). This study aimed to: evaluate the PTNB reactions to routine care in a NICU. This is an observational, descriptive, exploratory study. The sample consisted of 17 PTNB infants admitted to the NICU of a hospital in the interior of São Paulo, whose mothers or guardians accepted their participation in the study. This study was approved by Research Ethics Committees for data collection. Maternal and neonatal characterization data were collected from the medical records and those related to routine procedures (bathing, grouped care for hygiene and comfort, and medical physical examination) and PTNB reactions by filming for later analysis. Physiological parameters (HR and SatO2) were recorded minute by minute, during the periods: basal, manipulation and recovery. Facial mimetic was evaluated in the periods: basal, recovery 1 and 2 and body activities and asleep and awake states, in the periods: basal, manipulation and recovery. For HR and SatO2, the Wilcoxon statistical test was used to compare if there was a significant variation between the periods, with a significance level of 5%. The behavioral reactivity of the PTNBs was evaluated through the proportions of the facial activities and through the frequency and percentage distributions of the asleep and awake states and body movement. This procedure allowed the description of the most frequent behavioral reactivities in each of the periods evaluated in the different steps of routine care of the PTNBs. During bath, the HR medians varied between the periods: basal, manipulation and recovery, being respectively: 151.5, 152.9 and 149.2 bpm. The median values for SatO2 were: 97.2% 98.1% and 97.9% respectively. There was no statistical difference between the periods evaluated for these variables. In grouped care the median HR varied between the periods, as given: 159.1, 158 and 157.5 respectively. There was a statistically significant difference for HR between the basal and recovery periods, with p <0.05 (0.047). For SatO², the median values were: 97%; 97% and 97.1%, respectively. There was no statistical difference between the periods analyzed for this variable. For medical physical examination the median HR varied between: 153.5, 153.8 and 153.8 bpm in the mentioned periods. The median values for SatO² were: 98.4%, 98% and 97.8%, respectively. There was no statistical difference between the periods evaluated for these variables. During bath, the median values of facial mime ranged from: 16.7%, 20%, and zero respectively in the basal periods, recovery 1 and 2. In grouped care the values were: zero, 20% and 10%. Zero, 2.5% and zero, were the values considering the same periods in the medical physical examination. There was not statistically significant variation either in the frequency of body activities or in the frequencies of asleep and awake states between the periods established in the different caring types evaluated, prevailing regular, small, relaxed movements (AC1) and active asleep state, except in the manipulation during bath, for which crying prevailed. Although evaluations have taken place in routine care, there was a 5.9% of aspiration of VAS, considered by some authors as a painful procedure. The results also indicated the use of sucrose in 3 (17.6%) grouped care for hygiene and comfort. It is necessary to reevaluate the protocol for application of the use of this solution in the institution so that it is not offered indiscriminately in situations which do not involve painful procedures. We highlight the need to review some routine procedures applied to PTNBs, aiming to reduce the stress experienced by them
157

Chat na aprendizagem em enfermagem pediátrica e neonatal: percepção do estudante / Chat in pediatrics and neonatal nursing learning: perception of students

Delácio, Mayara Condé Brondi 25 November 2016 (has links)
O chat ou comunicação síncrona no ensino, apesar de incipiente, no Brasil, tem se apresentado como promissor para auxiliar no processo ensino-aprendizagem de estudantes. O presente trabalho tem o objetivo de analisar as atividades de chat educacional na aprendizagem da sondagem gástrica na criança, na percepção do estudante de enfermagem. Trata-se de um estudo documental retrospectivo com abordagem quali quantitativa com utilização de fonte secundária de dados das avaliações preenchidas por estudantes matriculados nas disciplinas de Saúde da Criança e do Adolescente dos dois cursos de graduação em Enfermagem da Escola de Enfermagem de Ribeirão Preto da Universidade de São Paulo no período de 2013 a 2015, num total de 202 estudantes. Os estudantes preencheram o instrumento \"Avaliação do Chat\" no Moodle em que as sessões de chat foram disponibilizadas, imediatamente após esta atividade. Os dados foram tabulados em planilhas do Excel e analisados por meio de tratamento estatístico com estatística descritiva (frequência e porcentagem). Para análise e categorização das expressões escritas pelos estudantes após participação na atividade de chat educacional foi utilizado a Análise de Conteúdo de Bardin onde as expressões foram agrupadas em seis categorias, dentre elas, O chat educacional e o auxílio no aprendizado e na prática; Condução do chat educacional; O chat educacional como ferramenta instigante; Duração adequada para discussão do tema; Número de participantes e sua interação; Necessidade de especialista sobre o assunto. Portanto, pode-se concluir que apesar da necessidade de repensar o tempo de duração da atividade, o chat educacional oferecido nas disciplinas foi uma atividade importante para o aprendizado, proveitosa e instigante, gerando no aluno a necessidade de mais sessões de chat com outros temas tanto nas disciplinas de saúde da criança e do adolescente, quanto em outras disciplinas oferecidas durante a formação. Concluiu- se, ainda, que o chat educacional sobre sondagem gástrica na criança atingiu o objetivo proposto, construindo o conhecimento de forma coletiva, auxiliando na autonomia do estudante no processo de ensino-aprendizagem, segundo a percepção destes / Although incipient in Brazil, chat or synchronous communication in education has presented itself as promising to assist in students\' teaching-learning process. The aim of the present study was to analyze educational chat activities in the learning of gastric suctioning in children, from the perception of nursing students. This is a retrospective documentary study with qualitative and quantitative approach and the use of secondary data from evaluations filled out by students who were enrolled in the disciplines of Children and Adolescents\' Health of the two nursing undergraduate programs of the Ribeirão Preto College of Nursing at the University of São Paulo, from 2013 to 2015, with a total of 202 students. Students filled out the \"Chat Evaluation\" instrument in the Moodle where the chat sessions were made available, immediately after this activity. The data were tabulated in Excel sheets and analyzed by means of statistical treatment with descriptive statistics (frequency and percentage). Bardin\'s content analysis was used for analysis and categorization of the expressions written by students after their participation in the educational chat activity, where the expressions were grouped into six categories, namely, Educational chat and assistance in learning and practice; Conduct of the educational chat; Educational chat as an exciting tool; Ideal duration for discussion about the subject; Number of participants and their interaction; Need for specialists on the subject. Therefore, it was concluded that despite the need for rethinking the length of the activity, the educational chat offered in the disciplines was important for learning, a useful and exciting activity, which created in students the need for more chat sessions with other subjects, both in the Children and Adolescents\' Health disciplines and in other disciplines offered during their education. In addition, the educational chat on gastric suctioning in children achieved the aim proposed by building knowledge in a collective way and assisting in the students\' autonomy in the teaching-learning process, according to their perception
158

Objeto digital no ensino da avaliação clínica do pré-termo: a aprendizagem de estudantes / Digital object in clinical evaluation teaching of preterm: students learning

Del\'Angelo, Natália 16 May 2012 (has links)
O objeto digital de aprendizagem \"Semiotécnica e semiologia do recémnascido pré-termo\" apresenta gradativamente a complexidade e as especificidades do recém-nascido pré-termo. Para verificar o impacto deste objeto no processo ensinoaprendizagem, tem-se como objetivos deste estudo avaliar a aprendizagem cognitiva de estudantes sobre o tema, auxiliada pelo uso deste objeto digital de aprendizagem em comparação à aula regularmente oferecida e avaliar subjetivamente o objeto digital. Trata-se de um quase-experimento com grupo controle (n=10) e grupo experimental (n=12) formados por estudantes de Licenciatura em Enfermagem de uma universidade do interior paulista. A intervenção foi o acesso ao objeto digital durante toda a disciplina, complementando o curso regular. A coleta de dados foi executada por meio da caracterização dos sujeitos, pré e pós-teste e avaliação subjetiva sobre o aplicativo. Para análise dos dados utilizou-se estatística descritiva. O estudo demonstrou que não houve diferença significativa entre os grupos (p=0,127) através do teste Mann-Whitney, porém ao se considerar a comparação intra-grupos através do teste Wilcoxon, ambos obtiveram diferença significativa (p Controle= 0,008 e p Experimental= 0,025) demonstrando os efeitos da aprendizagem viabilizados pela disciplina. Quanto à avaliação qualitativa, os resultados foram muito satisfatórios, destacando que os alunos julgaram o objeto digital de aprendizagem positivamente em todos os aspectos avaliados através do instrumento de coleta de dados da avaliação subjetiva. Nota-se que mesmo não tendo sido encontrada diferença significativa entre os grupos, os estudantes que tiveram acesso à intervenção o avaliaram como um instrumento de aprendizagem muito bom, sugerindo que seu emprego na educação é importante do ponto de vista de inovação didática e motivador da aprendizagem. Recomenda-se outros estudos com a ampliação da amostra para verificação do impacto do uso do objeto digital de aprendizagem e de testes de retenção de aprendizagem em médio prazo. / The digital object of learning titled \"Semiotecnique and semiology of preterm newborn\" presents the complexity and specificities of preterm newborn gradually. To verify the impact of this object in teaching-learning process, the aim of this study was to evaluate the cognitive learning of students about the theme aided by the use of this digital object of learning in comparison to regular classes and evaluate the digital object in a subjective perspective. It is a quasi-experimental study with a control group (n=10 students) and an experimental group (n=12) composed of students of a teaching diploma nursing program in a public university from São Paulo state. The intervention was the access to the digital object during the entire course as a complement to regular course. Data collection was realized through sample characterization, pre and post test and subjective evaluation about the software. This study demonstrated no statistical significance difference between the groups (p=0.127) through Mann-Whitney test, nevertheless considering the intra groups comparison, both groups obtained significant statistically difference (p Control= 0.008 e p Experimental= 0.025) through Wilcoxon test showing learning effects enabled by the course. In regard to qualitative evaluation, the results were very satisfactory, highlighting that the students judged the digital object of learning positively in all evaluated aspects. Even without significant difference between groups, the students who accessed the digital object of learning had assessed it as a very good tool of learning, suggesting that its use in education is important to innovate didactic and to motivate learning. We recommend other studies with larger sample to verify the impact of the object and learning retention in medium-term.
159

Tipo de cateter central de inserção periférica e o motivo de sua remoção em uma coorte de neonatos / Type of peripherally inserted central catheter device and the reason for its removal in a cohort of neonates

Paiva, Eny Dórea 30 July 2012 (has links)
Introdução: Dispositivos de acesso venoso central tornaram-se vitais para a recuperação e sobrevivência dos neonatos e lactentes internados em Unidade de Terapia Intensiva Neonatal (UTIN). O cateter central de inserção periférica (CCIP) tem sido amplamente utilizado para atender às demandas terapêuticas dos neonatos e lactentes criticamente doentes e inovações nos dispositivos têm sido introduzidos e confeccionados com materiais biocompatíveis, como o silicone e o poliuretano, com único ou duplo lúmen. Objetivo: analisar a relação entre os tipos de cateteres centrais de inserção periférica (monolúmen de silicone e duplolúmen de poliuretano) instalados em neonatos e lactentes com os motivos de remoção do dispositivo. Método: coorte prospectiva, composta por neonatos e lactentes submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo, no período de 1 de julho de 2010 a 30 de junho de 2011. Os neonatos e lactentes foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 219/2010). Resultados: foram analisados dados referentes a 270 CCIPs, 189 (70%) cateteres de monolúmen e 81 (30%) de duplolúmen. Os dois grupos de cateteres apresentaram características demográficas, clínicas, terapêuticas e relacionadas ao procedimento de inserção do cateter homogêneas, exceto para as variáveis: diagnóstico prévio de septicemia (p=0,0210) e ocorrência de dificuldade de progressão do cateter na instalação do mesmo (p=0,0296). Contudo, o valor de p para o teste de homogeneidade para razão de chances do diagnóstico prévio de septicemia e da dificuldade de progressão do cateter, não demonstrou diferença estatística, p=0,955 e p=0,400, respectivamente. A taxa de densidade de incidência (TI) de remoção não eletiva para o cateter monolúmen de silicone foi 34,8 em 1.000 cateteres-dia e a do cateter duplolúmen de poliuretano foi 32,8 em 1.000 cateteres-dia. Houve diferença estatística significante, p=0,0005, na média do tempo de permanência entre os dois tipos de cateteres, maior para o dispositivo de duplolúmen de poliuretano, 14 dias em relação ao dispositivo de monolúmen de silicone, 10 dias. Entretanto, não é possível afirmar que a taxa de densidade de incidência entre os cateteres se diferem entre si ao se estimar a curva de sobrevida pelo método Kaplan Meier dos cateteres com remoção não eletiva. As curvas de sobrevivência de ambos os cateteres se sobrepõem, entretanto o valor do logrank (0,45) indica que não há diferença estatística entre a incidência de remoção não eletiva entre os cateteres. Dessa forma, a hipótese conceitual defendida no presente estudo não pode ser confirmada. Conclusão: os resultados do estudo apontaram que não há diferença estatística significante nas taxas de incidência de remoção não eletiva entre os dois grupos de cateteres. Entretanto, o CCIP de duplolúmen de poliuretano apresentou média de tempo de permanência maior comparado ao dispositivo de monolúmen de silicone. / Introduction: Central venous access devices have become vital to the recovery and survival of newborns and infants hospitalized in the Neonatal Intensive Care Unit (NICU). The peripherally inserted central catheter (PICC) has been widely used to supply the therapeutic demands of critically ill newborns. Innovation in the PICC devices have been available, made from biocompatible materials such as silicone and polyurethane, with single or double lumen. Objective: To analyze the relationship between the type of peripherally inserted central catheter device (silicone single lumen or polyurethane double lumen) used in neonates and infants with the reasons for their removal. Method: prospective cohort study consisting of neonates and infants undergoing installation of PICC devices, admitted at the NICU of a private hospital in the city of São Paulo in the period from July 1st, 2010 to June 30, 2011. The neonates and infants were enrolled at the time of catheters installation and followed up until PICC device removal. The research project was examined and approved by the Institutional Research Ethics Boards where the study was carried out (Protocol number 219/2010). Results: Data from 270 PICC devices installed in 213 neonates, 189 (70%) silicon single lumen catheter and 81 (30%) with polyurethane double lumen catheter devices, were analysed. The distribution of demographic, clinical, therapeutic and cathers insertion procedure variables were homogeneous between the two groups of catheters, except for the variables: previous diagnosis of septicemia (p=0,0210) and difficulty on the progression of the catheter during the catheter instalation (p=0,0296). However, the p value for homogeneity test for the odds ratio for the diagnosis of septicemia and the difficulty of catheter progression, no have statistical difference, respectively p=0,955 and p=0,400. The rate of incidence density (ID) for non-elective silicon single lumen catheter removal was 34,8 per 1.000 catheter-days and for the polyurethane double lumen catheter was 32,8 per 1.000 catheter-days. Difference statistically significant, p=0,0005, in the average of length of stay between the two types of catheters was found, the polyurethane double lumen was largest, 14 days, silicone single lumen was 10 days. However, it is not possible to state that the rate of incidence density between the catheters is different when estimated by the Kaplan Meier method survival curve of the catheters with non-elective removal. The survival curves of both catheters overlap in 20th to 25th days, and the logrank value, 0,45, indicates no statistical difference in the non-elective removal catheters incidences between the two types of catheters. Thus, the statistical hypothesis in the length of stay of non-elective removal between both catheters can not be rejected, not confirming the theoretical hypothesis of this study. Conclusion: The results of the study indicate that there is no statistically significant difference in the incidence rates of non-elective removal between the two types of catheters. However, the polyurethane double lumen catheter had higher length of stay mean compared to the silicone single lumen catheter.
160

Manipulação de recém-nascidos pré-termo: o cenário na UTI neonatal de um hospital do interior paulista / Handling preterm infants: the scenario at the neonatal ICU of a hospital in the interior of São Paulo State.

Pereira, Fabíola Lima 14 December 2009 (has links)
Introdução: O progresso tecnológico nas Unidades de Terapia Intensiva Neonatais (UTIN) possibilitou o aumento da sobrevida de recém-nascidos pré-termo (RNPT) muito imaturos. Este avanço tornou a UTIN estressante devido ao grande número de procedimentos invasivos, aos equipamentos, à presença de luz, ao ruído e à manipulação excessiva que contribuem para as alterações no desenvolvimento dos prematuros. Objetivo: Descrever a manipulação a que o RNPT é submetido na UTIN de um hospital do interior paulista. Metodologia: Estudo descritivo e exploratório realizado com 20 RNPT, os quais foram filmados, durante 24 horas consecutivas. As manipulações foram categorizadas em: monitoramento, terapêutica e de cuidado. Os procedimentos realizados conjuntamente foram considerados como uma manipulação na contagem da frequência de manipulações do RN. A duração foi registrada do início até o término de cada procedimento e, quando agrupado, foi considerado o momento exato do primeiro procedimento até o término do último, totalizando o período de uma manipulação em agrupamento. Resultados: Houve um total de 768 manipulações e 1.341 procedimentos, com médias de 38,4 e 67,05 respectivamente. As manipulações com apenas um procedimento (504) representaram 65,6% dos casos, e os agrupamentos contiveram de 2 a 10 procedimentos. Os profissionais foram responsáveis por 680 situações (91,8%) das manipulações contra 61 (8,2%) dos familiares. Os auxiliares de enfermagem foram os que mais manipularam os RNPT, com 597 (80%) manipulações realizadas apenas por eles e 5 manipulações auxiliando outros profissionais. A duração média do período de manipulação foi de 2 horas (h) 26 minutos (min) e 33 segundos (s). A mediana foi de 2 h 15 min 29 s e o desvio-padrão de 1 h 41 min 30 s. A duração total de tempo em que os RNPT foram submetidos à manipulação foi de 48 h 51 min, 9,37% do total de filmagem. O prematuro mais manipulado, durante as 24 horas, foi o RNPT3, com 5 h 9 min e 9 s em manipulação, e o RNPT17 foi manipulado no menor período de tempo, 53 min e 15 s. Os RNPT tiveram, em média, 19 h 28 min e 46 s sem ter sido manipulados contra 4 h 16 min 42 s de tempo de manipulação. A mediana do tempo sem manipulação foi de 19 h 44 min e 16 s e o desvio-padrão de 1 h 36 min e 53 s. O prematuro que teve o maior período sem ser manipulado, de forma ininterrupta, foi o RNPT18 com 5 horas 16 minutos e 18 segundos , e o que teve menor período máximo de descanso foi o RNPT2, com 30 min e 12 s. Conclusão: as manipulações individuais representaram a maior parte das manipulações, e, quando ocorrem os agrupamentos de cuidados, não houve uma organização dos procedimentos. Houve poucos procedimentos que visaram ao cuidado desenvolvimental. Preserva-se a manipulação com duração menor que 1 minuto, ainda que em frequências menores do que nos estudos anteriores. Ficou evidente a escassa participação da mãe e dos familiares no cuidado ao RNPT, apesar de a visita materna ser facilitada pela equipe. É necessário um envolvimento da equipe para promover maior participação dos familiares no cuidado aos RNPT. / Introduction: Technological progress at Neonatal Intensive Care Units (NICU) has allowed for increased survival of very immature preterm infants (PI). This advance has turned the NICU a stressful unit, due to the large number of invasive procedures, equipments, the presence of light, noise and excessive handling, contributing to alterations in the infants\' development. Objective: To describe the handling PI\'s are submitted to at the NICU of a hospital in the interior of São Paulo state. Method: Descriptive and exploratory study, involving 20 PI\'s who were filmed for 24 consecutive hours. The handling was categorized as: monitoring, therapeutics and care. Procedures carried out together were considering as one single manipulation in counting PI handling frequency. The duration was registered from the start until the end of each procedure and, when grouped, the exact moment when the first procedure started until the end of the last procedure totaled the group manipulation period. Results: In total, 768 manipulations and 1,341 procedures were counted, with averages amounting to 38.4 and 67.05, respectively. Manipulations involving only one procedure (504) represented 65.6% of cases, and grouped manipulations contained between 2 and 10 procedures. Professionals were responsible for 680 handling situations (91.8%), against 61 (8.2%) for relatives. Nursing auxiliaries were the professionals that most handled the PI\'s, performing 597 (80%) manipulations alone and 5 to help other professionals. The mean duration of the handling period was 2 hours (h) 26 minutes (min) and 33 seconds (s), with 2 h 15 min 29 s as the median and 1 h 41 min 30 s as the standard deviation. The total time during which PI\'s were submitted to manipulation was 48 h 51 min, i.e. 9.37% of total recordings. The most handled infant during the 24 hours was PI3, subject to 5 h 9 min and 9 s, against PI17 with the shortest handling time, 53 min and 15 s. The PI\'s mean time without handling was 19 h 28 min and 46 s, against 4 h 16 min 42 s of manipulation. The median time without manipulation was 19 h 44 min and 16 s and the standard deviation 1 h 36 min and 53 s. The infant with the longest uninterrupted period without handling was PI18, with 5 h 16 min and 18 s, against PI2 with the shortest maximum rest time, i.e. 30 min and 12 s. Conclusion: Most manipulations were individual and, when care is grouped, procedures were not organized. Few procedures were aimed at developmental care. Manipulations taking less than 1 minute still continue, although less frequently than in earlier studies. The scarce participation of mothers and relatives in PI care was evidenced, although the team facilitates maternal visits. Greater involvement by the team is needed to promote greater family participation in PI care.

Page generated in 0.4047 seconds