551 |
Avaliação da adaptação marginal após apicectomia e selamento apical com laser Nd: YAGZerbinati, Lívia Prates Soares January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:10Z (GMT). No. of bitstreams: 2
000431773-0.pdf: 2376290 bytes, checksum: f2c60a6fa4a04eb80d3f349bc9b04f4d (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The new methods and materials used in paraendodontic surgery lead to a higher success rates in dental practice. The aim of this study was to evaluate the association of apicoectomy, retrofilling with MTA and the apical seal with Nd: YAG laser (10Hz, 150mJ, 1. 5 W, 60s). For these propose was used 40 teeth endodontically treated and cut by diamond bur at 90 ° with the long axis of the tooth. Four groups of samples was randomly assigned (n = 10): (A - apicoectomy, B - apicoectomy and Nd:YAG laser, C - MTA retrofilling, D - MTA retrofilling and Nd:YAG laser). The samples were embedded in epoxy resin and cut lengthwise first, then crosswise. SEM analysis showed a more homogeneous surface without apical sealing of dentinal tubules in groups B and D (p <0. 01). Horizontal and transverse marginal gaps were observed between dentin and filling material. The descending order of gap, was the group B (resection and irradiation Nd:YAG laser), followed by group A (apicoectomy), group D (MTA retrofilling irradiation and Nd: YAG laser) and at last group C (retrofilling MTA) (p <0. 01). The EDS analysis indicated a higher rates of phosphorus ions and lower of calcium in the groups treated by Nd:YAG laser. In conclusion, this research demonstrates the positive effect of application of Nd:YAG laser in apical sealing of the dentin surface, despite the dimensional effect that had on its association with the MTA. / As periapicopatias recidivantes são patologias de difícil resolução. Os novos métodos e materiais, aplicados na cirurgia paraendodôntica, têm adicionado índices de sucesso mais altos à prática odontológica. O objetivo deste trabalho foi avaliar as manobras de apicectomia associadas à retrobturação com MTA e ao selamento apical com laser Nd:YAG (10Hz, 150mJ, 1,5W, 60s). Utilizou-se 40 dentes endodonticamente tratados e apicectomizados com broca diamantada em 90° com o longo eixo do dente. Foram formados, randomicamente, quatro grupos de amostras (n=10): (A – apicectomia, B – apicectomia e irradiação laser Nd:YAG, C – apicectomia+retrobturação com MTA, D – apicectomia+retrobturação com MTA e irradiação laser Nd:YAG). As amostras foram incluídas em resina epóxi e cortadas, primeiramente no sentido longitudinal, depois no sentido transversal. A análise por MEV demonstrou uma superfície apical mais homogênea e sem canalículos dentinários nos grupos B e D (p<0,01). Foram observadas fendas marginais, entre dentina e material obturador, em ordem decrescente de tamanho, desde o grupo B, grupo A, grupo D e grupo C (p<0,01). A análise por EDS indicou uma porcentagem maior de íons fósforo e menor de cálcio nos grupos irradiados com laser Nd:YAG. Em conclusão, esta pesquisa demonstra o efeito positivo da aplicação do laser Nd:YAG no selamento da superfície dentinária, apesar do efeito dimensional que causou na sua associação com o MTA.
|
552 |
Avaliação da alteração dimensional alveolar após reabilitação com implante e provisório imediatos através de tomografia computadorizada de feixe cônicoDeon, Fernando January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:10Z (GMT). No. of bitstreams: 2
000431122-0.pdf: 718443 bytes, checksum: 42bf2deae17a40ea4bb251c259f660b0 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / O estudo teve como objetivo avaliar a alteração dimensional da parede óssea vestibular em um protocolo de implante e provisório imediatos em alvéolos pós-exodontia, através de tomografia computadorizada cone beam. Foram selecionados 7 pacientes consecutivos que necessitavam exodontia de um dente maxilar, na região de 13-23. Após extração cuidadosa e sem elevação de retalho, foi inserido um implante cônico de 3,5mm de diâmetro. Um provisório foi confeccionado após a inserção do implante, sem contatos cêntricos ou excêntricos e permaneceu por 90 dias, quando foi confeccionada uma prótese definitiva. Todos pacientes realizaram uma tomografia computadorizada cone beam aos 7 e 90 dias de pós-operatório. Em ambos os exames foram realizados mensurações na parede óssea vestibular em relação ao implante. Em todos os pacientes houve reabsorção da parede óssea vestibular, no sentido vertical e horizontal, e neoformação óssea no gap horizontal após o período de 90 dias. Houve diferença significativa entre os pacientes na reabsorção horizontal, com uma redução média de 0,41mm. O preenchimento ósseo no gap horizontal também foi significativo, com uma média de 0,77mm. A reabsorção vertical da parede óssea vestibular teve uma redução média de 0,70mm, porém sem diferença significativa. O presente estudo demonstrou que ocorre reabsorção alveolar da parede óssea vestibular, horizontal e vertical, após o protocolo de implante e provisório imediatos, assim como ocorre neoformação óssea no gap horizontal. Contudo, é necessário estudos com um tempo de acompanhamento maior para que se tenha um melhor entendimento do reparo ósseo alveolar que ocorre após a inserção de um implante imediatamente após exodontia.
|
553 |
Influência da transfixação horizontal por um pino de fibra de vidro na resistência à fratura de molares endodonticamente tratadosBeltrão, Maria Cecilia Gomes January 2005 (has links)
Made available in DSpace on 2011-12-27T14:14:12Z (GMT). No. of bitstreams: 2
000347433-0.pdf: 2385324 bytes, checksum: b30cdf7cb8df14803e76ba57e57535bb (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to assess the effect of a horizontally transfixed fiber glass post on the fracture resistance of molar teeth endodontically treated with MOD preparations, restored or not with composite resin. Seventy-five sound human third molars were extracted and mounted on acrylic resin blocks and were randomly assigned to five groups (n=15). In Group A, the teeth remained sound (control). Groups B, C, D and E, treated endodontically, were subjected to the following procedures: Group B – MOD preparation, group C – MOD preparation and transfixed post, group C – MOD preparation and resin composite restoration, group E – MOD preparation, transfixed post, and composite resin. The samples were stored in physiological serum at 37ºC for 24 hours. Later, a compressive force was applied parallely to the long axis of the teeth to fracture, performed by means of a universal testing machine (EMIC DL-2000) at 1 mm/min speed. The means in Newtons (N) of the results (standard deviation) followed by the same letter did not show a statistic difference for ANOVA and Tukey, p=0. 05: Group A = 4289. 8 (± 1128. 9)a, Group B = 549. 6 (± 120. 7)b, Group C = 1474. 8 (± 338. 1)c, Group D = 1224. 7 (± 236. 0)c, Group E = 2645. 4 (± 675. 1)d. In the analysis of qualitative variables, cusp fracture prevailed in 56%, a recoverable diagnosis was found in all groups, except for Group C, and the palatal cusp preparation prevailed in all Groups, except for Group A. It was concluded that a fiber glass post transfixed horizontally to the walls of a MOD cavity significantly increased fracture resistance, and when associated to the composite resin restoration, it established a fracture pattern compatible with the recovery of the dental specimen. / A proposta deste estudo foi avaliar o efeito, na resistência à fratura, de um pino de fibra de vidro transfixando horizontalmente as paredes, de um preparo MOD, de dentes molares tratados endodonticamente restaurados ou não com resina composta. Setenta e cinco dentes terceiros molares humanos hígidos foram extraídos e montados em blocos de resina acrílica, sendo distribuídos aleatoriamente em cinco grupos (n=15). No Grupo A, os dentes foram mantidos hígidos (controle). Os Grupos B, C, D e E, com tratamento endodôntico, receberam os seguintes procedimentos: Grupo B – preparo MOD; Grupo C – preparo MOD e pino transfixado; Grupo D – preparo MOD e restauração com resina composta; Grupo E – preparo MOD, pino transfixado e restauração com resina composta. As amostras foram armazenadas em soro fisiológico a 37ºC durante 24 horas. Após o procedimento, foi aplicada uma força compressiva paralela ao longo eixo dos dentes até a fratura, conduzida por meio de uma máquina de ensaio universal (EMIC DL-2000) com velocidade de 1mm/min. As médias em Newtons dos resultados (desvio padrão) seguidas de mesma letra não apresentaram diferença estatística para ANOVA e Tukey, p=0,05: Grupo A = 4289,8 (± 1128,9)a, Grupo B = 549,6 (±120,7)b, Grupo C = 1474,8 (± 338,1)c, Grupo D = 1224,7 (± 236,0)c, Grupo E = 2645,4 (±675,1)d. Na análise das variáveis qualitativas, predominou a fratura de cúspide em 56%, o diagnóstico recuperável em todos os grupos, com exceção do Grupo C e o preparo da cúspide palatina predominou em todos os grupos, a exceção do Grupo A. Concluiu-se que um pino de fibra de vidro transfixando horizontalmente as paredes de uma cavidade MOD elevou significativamente a resistência à fratura e quando associado à restauração de resina composta determinou um padrão de fratura compatível com a recuperação da peça dentária.
|
554 |
Avaliação da resistência à união dentinária entre tratamento ultra-sônico e alta rotação na interface dente/material restauradorConde, Alexandre January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:13Z (GMT). No. of bitstreams: 2
000387554-0.pdf: 6424305 bytes, checksum: eede53bc1323d5be8d0e3d939fde81ca (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Seventeen extracted healthy third molars were used in order to evaluate dentine as to: microtensile bond strength (μTBS) with Z250 resin composite (CR), and 3M Single Bond 2 adhesive; appearance previous to adhesive treatment (APTA); adhesive union (UA); type of fracture by Scanning Electron Microscope (SEM), and energy dispersion spectroscopy (EDS), comparing the treatment with a KGSorensen diamond bur (PD) and a CVDentus (UT) ultrasound tips with (c/a) and without (s/a) etching. Four groups (n=40) were divided according to the dentin processing (PDs/a - diamond bur without etching); (PDc/a - diamond bur with etching); (UTs/a - ultrasound tip without etching); (UTc/a - ultrasound tip with etching) were restored, embedded in politetrafluoretilene tube using chemically activated acrylic resin, and sectioned into samples for μTBS testing in an EMIC DL-2000 universal machine (0. 5 mm/min). Samples were analyzed by SEM and EDS for fracture classification UA and APTA. Statistical tests were: Kolmogorov- Smirnov Test; Two way Variance Analysis; Tukey and Fisher's Exact Test (p≤0,05). Failures were classified as: cohesive in dentine (CD); cohesive in CR (CM); cohesive interfacial on the base or top of hybrid layer (CBT); adhesive cohesive interfacial (CA); mixed (M); interfacial on smear layer (S). Results showed (group, average μTBS in MPa - standard deviation): (UTc/a, 45. 31-8. 16); (PDc/a, 34. 04-9. 29); (UTs/a, 15. 17-3. 71); (PDs/a, 9. 86-3. 80).The PD method is associated to CBT, and the UT method is associated to CA and CM; c/a is associated to CBT and CM, and s/a is associated to S. APTA showed: PDs/a - total obstruction of dentinal tubules (cd); UTs/a - partial disobstruction of cd and irregular surface appearance; PDc/a - complete disobstruction of cd; UTc/a - complete disobstruction of cd, and irregular surface appearance. UA showed: PDs/a rectilinear hybrid layer occurred without tags penetration (PT); UTs/a, curvilinear with a few PT; PDc/a, rectilinear with PT; UTc/a, curvilinear with PT. It was concluded that the association of UTc/a treatment promotes higher values of μTBS. There is an association between CBT failure and the PD method, failures CA and CM and the UT method, failures CBT and CM and the c/a method, and failure S and the s/a method. The failures that caused higher resistance to its rupture were, in a decreasing order: CD; CM; CBT; CA; M, and S. / Dezessete terceiros molares hígidos extraídos foram utilizados com objetivo de avaliar a dentina quanto: resistência à união por microtração (μTBS) com resina composta (CR) Z250 e adesivo Single Bond 2 (3M); aspecto prévio ao tratamento adesivo (APTA); união adesiva (UA); tipo de fratura por microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (EDS) comparando o tratamento com ponta diamantada KGSorensen (PD) e haste ultra-sônica CVDentUS (UT) com (c/a) ou sem (s/a) condicionamento ácido. Quatro grupos (n=40) divididos conforme processamento dentinário (PDs/a; PDc/a; UTs/a; UTc/a) foram restaurados, incluídos em resina acrílica autopolimerizável e transformados em pequenas barras por máquina de corte seriado para posterior ensaio de μTBS em máquina universal EMIC DL-2000 (0,5 mm/min). As amostras foram analisadas por MEV e EDS para classificação de fratura, UA e APTA. Os testes estatísticos foram: Kolmogorov-Smirnov; Análise de Variância fatorial; Tukey e Exato de Fisher (p≤0,05). As falhas foram classificadas em: Coesiva em dentina (CD); coesiva em CR (CM); interfacial coesiva na base ou topo de camada híbrida (CBT); interfacial coesiva adesiva (CA); mista (M); interfacial no smear layer (S). Os resultados mostraram (grupo, média μTBS em MPa - desvio padrão): (UTc/a, 45,31-8,16); (PDc/a, 34,04-9,29); (UTs/a, 15,17-3,71); (PDs/a, 9,86-3,80). O método PD está associado à CBT e o método UT às CA e CM, c/a está associado às CBT e CM e s/a à S. O APTA mostrou: PDs/a total obstrução dos canalículos dentinários (cd); UTs/a parcial desobstrução dos cd e aspecto irregular de superfície; PDc/a completa desobstrução dos cd; UTc/a completa desobstrução dos cd e aspecto irregular de superfície. Em PDs/a ocorreu camada híbrida retilínea sem penetrações de tags (PT); UTs/a, curvilínea com algumas PT; PDc/a, retilínea com PT; UTc/a, curvilínea com PT. Concluiu-se que a associação do tratamento UTc/a promove valores maiores de μTBS. Existe associação entre falha CBT com o método PD, falhas CA e CM com o método UT, falhas CBT e CM com o método c/a e falha S com o método s/a. As falhas que ofereceram maior resistência para seu rompimento são, em ordem decrescente: CD; CM; CBT; CA; M; S.
|
555 |
Utilização do cimento de fosfato de cálcio (Norian®) associado a enxertos onlay de calota craniana em região mandibular de ratos: estudo experimental : análise histológica, histométrica e biomecânicaSilveira, Roger Lanes January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:16Z (GMT). No. of bitstreams: 2
000425706-0.pdf: 3229059 bytes, checksum: 45284ea4f41049f07baee7ea1b986c3f (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This present work has analyzes the integration level of onlay bone grafts of the skull in rats’ mandibular region, combined or not with calcium phosphate cement (Norian ). For this, histology, morphometry, and biomechanical test of traction force have been evaluated. Twenty seven male Wistar rats were subjected to removal of bicortical grafts of the skullcap and fixed in the mandibular angles. The animals were divided into 6 groups: C21d – graft fixation (control – death after 21 days); I21d – graft fixation with Norian powder between the graft and recipient bed (death after 21 days), B21d - graft fixation and placement with Norian , acting as a barrier on the edges of the bone graft (death after 21 days) C55D - graft fixation (control - 55 days after death); I55d - graft fixation with Norian powder between the graft and the recepient bed (death after 55 days); B55d - graft fixation and placement with Norian , acting as a barrier on the edges of the graft (death after 55 days). The hemi-jaws on the left side were taken to the histology and histometric exam and hemi-jaws of the right to a traction force test.There was no infection in none of the cases or postoperative complications. Histological and histometric analysis – Norian ’s remnants were seen in both 21 and in 55 days, showing a gradual replacement by vascularized bone tissue; a higher bone formation was observed in the graft / bone interface receptor (GBIR) on the left side in the groups using the calcium phosphate (B21d, B55d and I55d in relation to C21d) (p = 0. 043); a better result was also observed in regard to the total newly formed bone on the left side interface of these same groups (p = 0. 08); the I55d group presented superior results than the control groups (C21d and C55d) and the group B21d concerning the GBIR bone formation on the right side (p = 0. 045); about the item on the horizontally newly formed bone on the left side, the group C21d had no significant difference in comparison to C55d, however, it presented less bone formation than the other groups that used the calcium phosphate (p = 0. 018). The traction force test - different devices have been developed to achieve an effective fixation of the specimens during the mechanical test, such as the EMIC DL-200 machine and the MTest 3. 0 version program to obtain the strength necessary to remove the grafts measured in Newton (N).The traction test demostrated that the C21d group’s results were significantly lower than other groups (p = 0. 08), furthermore, in two specimens from this group, one graft was not integrated and the other was weakly attached to the bone receptor. Comparing the control groups (21d and 55d), over time, there was a significant increase of the strenght required for the removal of the graft (p = 0. 032). The study showed good results in the use of onlay grafts associated with Norian , presenting higher levels of bone formation, even when dealing with a region of constant muscle stress. Furthermore, there was a better biomechanic integration, especially in the initial and most critical part of healing. / O presente trabalho analisou o nível de integração de enxertos ósseos onlay de calota craniana de ratos, em região mandibular, associados ou não ao cimento de fosfato de cálcio (Norian®). Para isso, foram realizadas avaliações histológicas, histométricas, além de teste biomecânico de força de tração. Vinte e sete ratos Wistar, machos, foram submetidos à remoção de enxertos bicorticais da calota craniana e fixados nos ângulos mandibulares. Os animais foram divididos em 6 grupos: C21 d - fixação do enxerto (controle - morte após 21 dias); 121 d - fixação do enxerto com o pó do Norian® entre o enxerto e o leito receptor (morte após 21 dias); B21 d - fixação do enxerto e colocação de Norian®, atuando como barreira, sobre as bordas do enxerto (morte após 21 dias); C55d - fixação do enxerto (controle - morte após 55 dias); 155d - fixação do enxerto com o pó do Norian entre o enxerto e o leito receptor (morte após 55 dias); B55d - fixação do enxerto e colocação de Norian, atuando como barreira, sobre as bordas do enxerto (morte após 55 dias). As hemimandíbulas do lado esquerdo foram destinadas ao exame histológico e histométrico e as hemi-mandíbulas do lado direito ao teste de força de tração. Em nenhum dos casos ocorreu infecção ou complicações pós-operatórias.Análise histológica e histométrica - resquícios do Norian foram vistos tanto em 21 quanto em 55 dias, demonstrando uma gradual substituição por tecido ósseo vascularizado; foi observada uma maior formação óssea na interface enxerto/osso receptor (TEOR) do lado esquerdo nos grupos que utilizaram o fosfato de cálcio (B21d, B55d e 155d em relação ao C21 d) (p= 0,043); um melhor resultado também foi observado em relação ao osso total neoformado na interface do lado esquerdo, nesses mesmos grupos W-0,08); o grupo 155d apresentou resultados superiores aos grupos controle (C21d e C55d) e ao grupo B21d na formação de osso na IEOR do lado direito (p= 0. 045): no item osso neoformado horizontalmente do lado esquerdo, o grupo C21d não apresentou diferença significativa em relação ao C55d, contudo, demonstrou haver formado menos osso que os demais grupos que utilizaram o fosfato de cálcio (p= 0,018). Teste de força de tração - diferentes dispositivos foram desenvolvidos para conseguir uma fixação eficaz dos espécimes durante o ensaio mecânico, sendo utilizada a máquina EMIC® DL-200 e o programa MTest versão 3. 0 para obtenção das forças de remoção dos enxertos em Newton (N). O teste de tração demonstrou que o grupo C21d apresentou resultados significativamente inferiores aos demais grupos (p= 0,08), além disso, em dois espécimes deste grupo, um enxerto não estava integrado e o outro estava fracamente aderido ao osso receptor. Comparando-se os grupos Controle (21d e 55d), ao longo do tempo, houve um aumento significativo na força necessária para a remoção dos enxertos (p= 0,032). O estudo demostrou bons resultados na utilização dos enxertos onlay associados ao Norian®, apresentando maior nível de formação óssea, mesmo se tratando de uma região de constante estresse muscular. Além disso, houve uma melhor integração biomecânica, principalmente na fase inicial e mais crítica da cicatrização.
|
556 |
Retração de caninos superiores com bráquetes autoligados e convencionaisMezomo, Maurício Barbieri January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2
000414875-0.pdf: 8343665 bytes, checksum: eca6520ad66453c0339e6ec79200478b (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this split mouth randomized clinical trial was to evaluate and compare the space closure during the retraction of upper permanent canine with self-ligating "SmartClip" and conventional "Gemini" brackets. Sample complied 13 patients with Class I biprotrusion or Class II 1st division malocclusion, with an average age of 18 years and 4 months, 3 male and 10 female. All were submitted to the therapeutic extraction of two first premolars. The retraction of the upper canines was performed with elastomeric chain with 150g of force. The evaluations were performed at four times (T1 – initial, T2 – 4 weeks, T3 – 8 weeks, T4 – 12 weeks) in stone model casts. The amount of movement and the rotation of the canines as well anchorage loss of upper first molars were evaluated. The space closure measurement was made between canine and second premolar and rotation was assessed by an angle formed by the intersection of the line drawn through the canine’s contact points and the line of the palatal suture. The anchorage loss was measured by a guide adapted at the palatal rugae in stone casts at initial and end.The data obtained were subjected to Student t test considering level of significance of 5%. The results shown that selfligating bracket had an average of 0. 92 mm (+/- 0. 29) of rate movement and 8. 46o (+/- 4. 68) of the rotation of the upper canines and 0. 65 mm (+/- 0. 24) of anchorage loss; the conventional bracket had an average of 0. 84 mm (+/- 0. 22) of rate movement and 11. 77o (+/- 3. 26) of the rotation of and the upper canines and 0. 57 mm (+/- 0. 24) of anchorage loss. There was no difference (p=0. 250) in the rate of movement of the canines between the two types de brackets. The rotational control of the canines was better promoted by self-ligating bracket (p=0. 005). There was anchorage loss for both groups, with no statistical difference between them (p=0. 157). / O objetivo deste ensaio clínico randomizado tipo boca dividida foi avaliar e comparar o fechamento dos espaços durante a retração dos caninos permanentes superiores com os bráquetes autoligado “SmartClip” e convencional “Gemini”. A amostra foi constituída de 13 pacientes portadores de maloclusão de Classe I com biprotrusão ou Classe II 1ª divisão de Angle, com média de idade de 18 anos e 4 meses, sendo 3 do gênero masculino e 10 do feminino. Todos os indivíduos foram submetidos à extração terapêutica dos primeiros pré-molares superiores. A retração dos caninos foi realizada através de cadeia elastomérica com força de 150g. As avaliações foram realizadas nos tempos (T1 – inicial, T2 – 4 semanas, T3 – 8 semanas, T4 – 12 semanas) através de modelos de gesso. Foram analisadas a taxa da movimentação e rotação dos caninos bem como a perda de ancoragem dos primeiros molares permanentes superiores. A mensuração do fechamento dos espaços foi realizada entre o canino e o segundo pré-molar e a rotação através do ângulo formado pela intersecção da linha que passava pelos pontos de contato dos caninos com a linha da rafe palatina mediana. A perda de ancoragem foi medida por um guia adaptado às rugas palatinas nos modelos de gesso inicial e final. Os dados obtidos foram submetidos a análise estatística através do teste t-Student considerando o nível de significância de 5%. Os resultados demonstraram que o bráquete autoligado apresentou taxa média de movimentação mensal de 0,92mm (+/- 0,29) e rotação de 8,46o (+/- 4,68) dos caninos superiores e a perda de ancoragem de 0,65mm (+/- 0,24); o bráquete convencional apresentou taxa média de movimentação mensal de 0,84mm (+/- 0,22) e rotação de 11,77o (+/- 3,26) dos caninos superiores e a perda de ancoragem de 0,57mm (+/- 0,24).Não houve diferença significativa (p=0,250) entre a taxa de movimentação dentária dos caninos entre os dois tipos de bráquetes. O controle de rotação dos caninos foi melhor promovido pelo bráquete autoligado (p=0,005). Ocorreu perda de ancoragem para ambos os grupos, sem diferença estatística entre eles (p=0,157).
|
557 |
Efeito do laser de baixa intensidade na prevenção e tratamento da mucosite bucalPinto, Tatiana Andrea Soares January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2
000423852-0.pdf: 2665164 bytes, checksum: 9f26ad41868f1b538746e7a2692aee80 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / OBJECTIVES: This study compared the results obtained in the prevention and treatment of chemotherapy-induced oral mucositis using InGaAIP diode laser in two different protocols: therapeutic and prophylactic/therapeutic treatment. In addition, we evaluated changes in the clinical picture of pain before and after laser therapy in different degrees of mucositis. METHODS: Patients (n=14) treated with chemotherapy at Hospital São Lucas of Pontifícia Universidade Católica do Rio Grande do Sul, Brazil, with no previous mucositis, were randomized into a therapeutic group (group 1) and a prophylactic/therapeutic group (group 2). The occurrence of mucositis was evaluated in both groups and classified according to World Health Organization (WHO) criteria. After low level laser application in the treatment of mucositis, we compared pain intensity before and after laser therapy using the visual analog scale (VAS). RESULTS: Group 2 showed a lower degree of mucositis (p=0.004) and shorter time to remission (p=0.042) when compared to group 1. Pain intensity after laser therapy was significantly lower than before laser therapy in grade 2 (p=0.002) and grade 3 (p=0.005) mucositis. CONCLUSION: The use of low level laser irradiation in the prophylactic/therapeutic protocol, when compared to the therapeutic protocol, results in shorter healing time and greater control over the severity of chemotherapy-induced oral mucositis. / O presente estudo comparou os resultados obtidos na prevenção e tratamento da mucosite bucal resultante da quimioterapia, a partir do uso do laser diodo (meio ativo: InGaAIP) em dois protocolos distintos: protocolos terapêutico e profilático-terapêutico. Além disso, foi avaliada a alteração do quadro de dor antes e após a laserterapia nos diferentes graus de mucosite. Pacientes (n=14) submetidos ao tratamento quimioterápico no Hospital São Lucas da Pontifícia Universidade Católica do Rio Grande do Sul (HSL/PUCRS) com ausência prévia de mucosite, foram distribuídos nos grupos terapêutico (grupo 1) e profilático-terapêutico (grupo 2). A ocorrência da mucosite foi avaliada em ambos os grupos e classificada segundo os critérios da Organização Mundial da Saúde (OMS). A partir da aplicação do laser de baixa intensidade no tratamento da mucosite, comparou-se a intensidade da dor pré e pós-laserterapia através da escala visual analógica (EVA). Verificou-se que o grupo 2 apresentou menor grau de mucosite (p=0,004) e menor tempo de remissão (p=0,042) em comparação ao grupo 1. A intensidade da dor pós laserterapia foi significativamente menor que a pré, nas nomucosites graus II (p=0,002) e grau III (p=0,005). Mediante os resultados obtidos constatou-se que o uso do laser de baixa intensidade sob o protocolo profilático-terapêutico, quando comparado ao protocolo terapêutico, resulta em menor tempo de cicatrização e maior controle da gravidade da mucosite bucal resultante da quimioterapia.
|
558 |
Análise da superfície dentinária radicular seccionada com broca e laser Er:YAG e fusionada com laser Nd:YAG por meio de MEV e EDSFarret, Alessandro Marchiori January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2
000426252-0.pdf: 1654868 bytes, checksum: 382d5341f921278e1be939282bf6a9c2 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the dentine surface of 20 lower bovine incisors which were undergone to root section with high-speed bur or Er:YAG laser, also using laser fusion of dentine by Nd:YAG laser. The teeth were assigned in two groups. In the first group the teeth were sectioned with high-speed bur with constant refrigeration and in the second group the teeth were sectioned with Er:YAG laser in the pulse mode, with 10 Hz of frequency and pulse energy of 500 mj (5 W of potency) under constant refrigeration with spray water/air from 3 mm of the tooth. Both methods of cut performed two surfaces, one of them was fused by Nd:YAG laser and the another one was kept without surface treatment. Through the Scanning Electron Microscopy (SEM), were done images of the surfaces and through the Energy Dispersion Spectroscopy (EDS) were obtained data about the molecular constitution of the remaining surfaces. For the comparison among the 4 groups the non-parametric test of Kruskal-Wallis was used. The results were considered significant at a maximum significance level of 5%. The group cut with bur without dentine fusion showed significant higher values of carbon in comparison with other groups.The group in which the teeth were sectioned by bur without surface treatment showed significant lower amounts of phosphorus in comparison with all other groups, followed by group where there was cut with bur and fusion by Nd:YAG and cut with Er:YAG and fusion by Nd:YAG, which did not differ between them. In the group with section by Er:YAG laser and without dentine treatment, were observed values of phosphorus significantly higher. The conclusion was that the cut surfaces with high-speed bur showed a smoother surface than the surfaces obtained with Er:YAG laser, visualized through the MEV analyses. Moreover, those same surfaces also showed lower amount of open dentine tubules, indicating that the method of section with bur could reduce the permeability of the dentine in comparison with Er:YAG laser even with the fusion by the Nd:YAG laser. / O objetivo deste trabalho foi avaliar a superfície dentinária de 20 incisivos inferiores bovinos, os quais passaram por secção radicular com utilização de broca de alta rotação ou laser Er:YAG, também utilizando fusão dentinária por laser de Nd:YAG. Os dentes foram separados em 2 grupos. No primeiro, os dentes foram seccionados com broca de alta rotação utilizando-se refrigeração constante, e no segundo grupo os dentes foram seccionados com laser Er:YAG, em modo pulsátil, com freqüência de 10 Hz, energia por pulso de 500 mj (potência de 5 W) e sob refrigeração constante do spray ar/água, à 3 mm do dente. Ambos os cortes geraram 2 superfícies, uma das quais passou por fusão com laser Nd:YAG e a outra permaneceu sem tratamento na superfície. Foram obtidas imagens por Microscopia Eletrônica de Varredura (MEV) e dados sobre a constituição molecular das superfícies remanescentes por meio de Espectroscopia de Dispersão de Energia (EDS). Para a comparação entre os 4 grupos utilizou-se o teste não-paramétrico Kruskal-Wallis. Os resultados foram considerados significativos a um nível de significância máximo de 5%. O grupo cortado com broca sem fusão dentinária apresentou valores significativamente superiores de carbono aos demais grupos. O grupo em que os dentes foram seccionados com broca sem tratamento da superfície apresentou quantidades de fósforo significativamente inferiores em relação a todos os outros grupos, seguido pelos grupos onde houve corte com broca e fusão por Nd:YAG e corte com Er:YAG e fusão por Nd:YAG, os quais não diferiram entre si. No grupo com secção por laser Er:YAG sem tratamento dentinário, observaram-se valores de fósforo significativamente superiores aos outros.Concluiu-se que as superfícies resultantes dos dentes que foram cortados com broca de alta rotação apresentaram superfície mais lisa ao exame de MEV do que as superfícies resultantes dos dentes cortados com laser Er:YAG. Além disso, estas mesmas superfícies também apresentaram menor índice de túbulos dentinários abertos, levando a crer que por este método de secção dentinária, a permeabilidade da dentina resultante será menor que a dentina cortada com laser Er:YAG, mesmo utilizando-se fusão por laser Nd:YAG.
|
559 |
Resistência de união à microtração de dentina pré-hibridizada: efeito dos métodos de tratamento de superfície e da temporizaçãoDillenburg, Álvaro Luis Kroeff January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2
000385863-0.pdf: 11730392 bytes, checksum: be18f24f5772871dae60f25e74a3ef0b (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated the influence of different surface treatments to dentin with pre-cured adhesive layer when the immediate dentin sealing technique (IDS) was applied in different storage time with provisional cement on microtensile bond strength of two adhesive systems, classified the failure pattern and measured the adhesive layer thickness. The dentin bonding agent (DBS) Single Bond 2 (SB2) (3M ESPE) e Prime&Bond NT (PB) (Dentsply) were tested in two storage times: 48 hours (A) and 4 months (B). Freshly prepared flat dentin surfaces of extracted human molars were coated with the adhesive systems according to the surface treatments groups: G1) aluminum-oxide - SB2; G2) 37% phosphoric acid - SB2; G3) oxide+acid - SB2; G4) aluminum-oxide - PB; G5) 37% phosphoric acid - PB; G6) oxide+acid - PB; G7) control - SB2; G8) control - PB. After curing the DBA, the provisional cement RelyXTemp NE (3M ESPE) was applied to the bonded dentin surface of the groups 1, 2, 3, 4, 5 and 6, and the teeth were stored for 48 hour or 4 months. After the storage, provisional cement layer was scaled off and the different surface treatments were applied followed by a second DBS layer. The control groups (7 and 8) didn’t received the provisional cement neither the second DBS layer, however were stored for the same times.The composite crown restoration was built with direct resin and, after 24h, the prepared teeth were serially sectioned in sticks. The specimens (n=20 per group) were submitted to microtensile strength test using the universal testing machine EMIC DL-2000. The average values (MPa) were (means followed by different letters are statistically different to General Linear Model and Turkey’s test (p<0,05)): G1A - 23,79±5,92(AB); G1B - 23,93±5,49(AB); G2A - 28,47±6,57(B); G2B - 27,84±3,31(B); G3A - 44,84±10,49(C); G3B - 44,37±9,07(C); G4A - 19,14±4,76(A); G4B - 18,51±4,64(A); G5A - 30,60±5,48(B); G5B - 28,30± 3,95(B); G6A - 47,22±10,11(C); G6B - 46,02±10,33(C); G7A - 41,57±6,91(C); G7B - 41,21±9,32(C); G8A - 40,17±10,35(C) e G8B - 41,04±11,21(C). The fractures specimens were analyzed by SEM and the mixed failure was predominant (92%) followed by interfacial failure (21%). The adhesive thickness range in increasing order: G8< G7< G4< G1< G6< G3< G5< G2. These results suggested that: the surface treatment with aluminum-oxide + 37% phosphoric acid provided the highest bond strength values, however the storage times and the DBS didn’t affect these values; the mixed failure was predominant followed by interfacial failure; and the surface treatments affected significantly the bonding layer thickness for both tested DBS. / Este estudo avaliou a influência de diferentes tratamentos de superfície na dentina pré-hibridizada com a técnica do selamento dentinário imediato (SDI) e armazenada por diferentes períodos na resistência de união à microtração de dois sistemas adesivos. Os agentes de união dentinária (AUD) utilizados, Single Bond 2 (SB2) (3M ESPE) e Prime&Bond NT (PB) (Dentsply), foram testados em dois períodos de armazenagem: 48 horas (A) e 4 meses (B). Superfícies planas de dentina foram preparadas em molares humanos extraídos e foram cobertas com o sistema adesivo de acordo com o tratamento de superfície de cada grupo: G1) óxido de alumínio - SB2; G2) ácido fosfórico 37% - SB2; G3) óxido+ácido - SB2; G4) óxido de alumínio - PB; G5) ácido fosfórico 37% - PB; G6) óxido+ácido - PB; G7) controle - SB2; G8) controle - PB. Após a polimerização do sistema adesivo o cimento provisório RelyXTemp NE (3M ESPE) foi aplicado sobre as superficies dentinárias previamente tratadas com adesivo dos grupos 1, 2, 3, 4, 5 e 6 e estes foram armazenados por 48 horas ou 4 meses. Após o período de armazenagem a camada de cimento provisório foi removida e os diferentes tratamentos de superfície foram empregados seguidos de uma segunda camada de AUD. Os grupos controle (7 e 8) não receberam o cimento provisório nem a segunda camada adesiva, sendo no entanto armazenados pelos mesmos períodos de tempo. Coroas de resina composta direta foram construídas e, após 24h, os dentes preparados foram seccionados em palitos. As amostras (n=20 por grupo) foram submetidas ao teste de resistência de união à microtração na máquina de ensaios universal EMIC DL-2000.Os valores médios (MPa) foram (médias seguidas de letras diferentes são estatisticamente diferentes para Modelo Linear Geral e teste de Tukey (p<0,05)): G1A - 23,79±5,92(AB); G1B - 23,93±5,49(AB); G2A - 28,47±6,57(B); G2B - 27,84±3,31(B); G3A - 44,84±10,49(C); G3B -44,37±9,07(C); G4A - 19,14±4,76(A); G4B - 18,51±4,64(A); G5A - 30,60±5,48(B); G5B - 28,30± 3,95(B); G6A - 47,22±10,11(C); G6B - 46,02±10,33(C); G7A - 41,57±6,91(C); G7B - 41,21±9,32(C); G8A - 40,17±10,35(C) e G8B - 41,04±11,21(C). O tipo de fratura foi analisado através de MEV e a falha do tipo mista foi predominante (92%) seguida da falha interfacial (21%). A espessura de adesivo variou em ordem crescente nos grupos: G8< G7< G4< G1< G6< G3< G5< G2. Os resultados sugerem que: o tratamento de superfície com óxido de alumínio + ácido fosfórico 37% proporcionou os maiores valores de resistência de união, no entanto o tempo de armazenagem e o AUD utilizado não afetaram estes valores; a falha mista foi predominante seguida da falha interfacial; e os tratamentos de superfície utilizados afetaram significativamente a espessura da camada adesiva para ambos os AUD testados.
|
560 |
Avaliação da resistência de união entre infra-estrutura de zircônia e cerâmica de cobertura comparado com um sistema metalo-cerâmicoCarlucci, Cristiano Lages January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2
000425713-0.pdf: 1781396 bytes, checksum: 7eeb594432bb477d3935d002b3c3bfbb (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this in vitro study was to evaluate the bond strength interface between the veneering and core zirconia ceramic of a system metal free compared to metal-ceramic system. For this, 40 blocks were made of zirconia (Procera Zirconia), where 32 without color and 8 color have A2) and 8 blocks of metal (alloy Viron 99), all the dimensions (10 x 10 x 2 mm). Samples of zirconia were divided into 5 groups (8 each), and received different preparations: Group 1 (zirconia without color): application of the dentin; Group 2 (zirconia A2 color): application of the dentin; Group 3 (zirconia without color): application of liner + dentin; Group 4 (zirconia without color): application of dentin + liner on the inner surface; Group 5 (zirconia without color): wear diamond drill + liner + dentin. As a control group: metal-ceramic (IPS Dsign Viron 99 + dentin A2). After sintering of ceramics according to the manufacturer, the samples were subjected to analysis of shear strength tests performed on machine EMIC DL 2000, where results were obtained in MPa. Through photographs and SEM with magnitude of 37X, 200X and 2000X as the type of failure that occurred at the interface core and veneering ceramic. When submitting the results to the ANOVA, it was possible to observe that there were statistically significant differences between groups (p=0,000). According to Tukey's test, the control group had the highest values of tensile bond strength, statistically different (P<0. 05) than other groups of zirconia. The groups of zirconia showed no statistical difference between them (p>0. 05). Group 2 had the highest average among the zirconia and group 4 had the lowest average of all groups. The flaws found in the joint interface were 100% in all samples and only 1 sample of group 2 it was cohesive failures in the core of zirconia. It was concluded that the control group showed a tensile bond strength approximately 50% higher than all groups of zirconia tested. / O objetivo deste estudo in vitro foi avaliar a resistência de união entre infraestrutura de zircônia e cerâmica de cobertura de um sistema livre de metal comparado com um sistema metalo-cerâmico. Para isso, foram confeccionados 40 blocos de zircônia (Procera Zirconia), onde 32 não possuíam cor e 8 possuíam cor A2) e 8 blocos metálicos (liga Viron 99), todos nas dimensões (10 x 10 x 2 mm). As amostras de zircônia foram divididas em 5 grupos (8 em cada), e receberam diferentes tratamentos: Grupo 1 (zircônia s/ cor): aplicação da dentina; Grupo 2 (zircônia c/ cor): aplicação da dentina; Grupo 3 (zircônia s/ cor): aplicação do liner + dentina; Grupo 4 (zircônia s/ cor): aplicação do liner + dentina na superfície interna; Grupo 5 (zircônia s/ cor): desgaste com broca diamantada + liner + dentina. Como Grupo Controle: metalo-cerâmica (viron 99 + IPS Dsign dentina A2). Após sinterização das cerâmicas de acordo com o fabricante, as amostras foram submetidas ao teste de resistência ao cisalhamento realizados em máquina de ensaios EMIC DL 2000, onde os resultados foram obtidos em MPa. Através de fotografias e de MEV com magnitude de 37X, 200X e 2000X foi verificado o tipo de falha que ocorreu na interface infra-estrutura e cerâmica de cobertura. Ao submeter os resultados ao teste ANOVA, foi possível observar que houve diferenças estatisticamente significantes entre os grupos (p=0,000). De acordo com teste de Tukey, o grupo controle obteve os maiores valores de resistência de união, estatisticamente diferente (p<0,05) aos demais grupos de zircônia. Os grupos de zircônia não apresentaram diferença estatística entre si (p>0,05). O grupo 2 apresentou a maior média entre os grupos de zircônia e o grupo 4 apresentou a menor média de todos os grupos testados. As falhas encontradas na interface foram 100% mistas em todas amostras e apenas 1 amostra do grupo 2 constatou-se falhas coesivas na infra-estrutura de zircônia. Concluiu-se que o grupo controle mostrou uma resistência de união aproximadamente 50% maior que todos os grupos de zircônia testados.
|
Page generated in 0.04 seconds