• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 30
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 157
  • 55
  • 50
  • 47
  • 46
  • 39
  • 34
  • 29
  • 28
  • 28
  • 25
  • 21
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Eletromiografia dos músculos temporais e masseteres em pacientes com disfunção temporomandibular tratados com placa interoclusal / Electromyography of the temporal and masseter muscles in patients with temporomandibular disorders treated with interocclusal splint

Crosio, Daniel Mazzetto 05 March 2010 (has links)
Os objetivos do presente estudo foram analisar os efeitos do tratamento de pacientes com Desordem temporomandibular (DTM) articular crônica com a placa interoclusal estabilizadora modelo Michigan por meio dos índices eletromiográficos POC dos temporais, POC dos masseteres, TORS, ASSIM, Ativação, Ativação absoluta, TORQUE, Impacto, em máximo apertamento dental voluntário (MCV) em máxima intercuspidação habitual (MIH) e máximo apertamento voluntário com algodão entre os dentes (MAA). Foram também analisados os sinais e sintomas de DTM. Participaram do estudo 20 sujeitos, jovens e adultos, sendo 10 com DTM articular crônica, que receberão tratamento com placa oclusal modelo Michigan (Grupo DTM) e 10 sujeitos sem sinais e sintomas de DTM (Grupo Controle). Os sujeitos passarão por exame clínico e responderão ao Protocolo para Determinação dos Sinais e Sintomas de DTM para Centros Multiprofissionais (Felício et al., 2006). Os registros e cálculos dos índices eletromiográficos serão realizados com o Eletromiógrafo Freely de oito canais (De Götzen srl; Legano, Milano, Italy). Foram comparados os dados do grupo DTM na fase de diagnóstico (FD) e na fase final (FF) de tratamento, bem como os dados deste grupo com os do grupo controle. Para os dados expressos em nível intervalar de mensuração, como os dos exames clínicos, foi empregada estatística não-paramétrica. Os dados em nível de razão, isto é os dados eletromiográficos, foram analisados por meio de estatística paramétrica. O nível de significância estabelecido foi de 5%. / The objectives of this study were to analyze the effects of treatment of patients with temporomandibular disorder (TMD) joint with chronic plaque-stabilizing model interocclusal Michigan through electromyographic indices of temporal POC, the POC masseter, TORS, SO, Activation, Activation absolute TORQUE, Impact, for maximum voluntary tooth clenching (MCV) in maximum intercuspal usual (MHI) and maximum voluntary clenching with cotton between teeth (MAA). We also analyzed the signs and symptoms of TMD. The study included 20 subjects, young people and adults, and 10 with chronic articular TMD, which would be treated with occlusal splints Michigan model (DTM Group) and 10 subjects without signs and symptoms of TMD (control group). The subjects will undergo clinical examination and respond to the Protocol for the Determination of the signs and symptoms of TMD for multi Centers (Felicio et al., 2006). Records and calculations of indices electromyographic out with the electromyograph Freely eight channels (De Götzen srl; Legano, Milano, Italy). We compared the data from the DTM group stage of diagnosis (FD) and the final stage (FF) treatment, as well as data from this group with the control group. For data expressed as interval level of measurement, such as clinical examination, was used non-parametric statistics. Data on level of reason, ie electromyographic data were analyzed using parametric statistics. The significance level was set at 5%.
92

Efeito do uso da placa oclusal resiliente em indivíduos portadores de disfunção temporomandibular - avaliação clínica e eletromiográfica / The effects of the resilient occlusal splint use in individuals with temporomandibular dysfunction clinical evaluation and electromyographic

Ana Maria Bettoni Rodrigues da Silva 30 April 2009 (has links)
Para melhor compreender a fisiopatologia que afeta a musculatura do sistema estomatognático, a análise eletromiográfica dos músculos da mastigação tem sido incluída em muitos estudos. A eletromiografia (EMG) permite verificar e avaliar a eficácia muscular, entre os músculos de ambos os lados do corpo (simetria) e entre pares de músculos, com um possível efeito de desvio lateral da mandíbula (torque) (Ferrario et al., 1999, 2002). O objetivo desse trabalho foi estudar por meio da EMG de superfície os músculos masseter (porção superficial) e temporal (porção anterior) bilateralmente, e verificar o efeito do uso da placa oclusal resiliente, como um dos recursos para o tratamento das desordens temporomandibulares (DTMs), e comparar com um grupo controle. Foram envolvidos 23 indivíduos com sinais e sintomas de DTM, avaliados clinicamente, que receberam depois tratamento com placas oclusais resilientes. Para estabelecer a presença ou ausência de DTM, foi utilizado o Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD); além de registrar a atividade EMG dos músculos masseter e temporal, bilateralmente, antes (inicial Etapa 1), 30 (Etapa 2) e 60 dias após o uso da placa oclusal resiliente (Etapa 3) (Pettengill et al., 1998); relacionar os achados eletromiográficos com a avaliação clínica da oclusão e das funções estomatognáticas; comparar os resultados de uma população com DTM e o grupo controle de 23 indivíduos. As avaliações EMG foram registradas por meio de movimentos de mastigação e das condições clínicas de repouso, lateralidade com contato bilateral, protrusão e apertamento dental. A análise estatística foi realizada com o emprego do software SPSS versão 15.0 (Chicago, IL, USA). Devido ao fato de que foi rejeitada a hipótese de normalidade da grande maioria das variáveis (Teste de Shapiro-Wilks) foram utilizados métodos não-paramétricos na análise. O nível de significância adotado foi p ≤0,05. Os dados dos grupos controle e DTM foram comparados por meio do teste não-paramétrico de Mann-Whitney, e as comparações intragrupo DTM (inicial, 30 e 60 dias de uso de placa) foram realizadas por meio do teste não-paramétrico de Wilcoxon. De acordo com os resultados, na condição clínica de repouso, não houve diferença estatisticamente significativa na comparação entre os grupos controle e DTM; e foi observado diferença estatisticamente significativa intra-grupo de DTM. Na condição clínica de lateralidade direita, houve diferença estatisticamente significativa na comparação entre os grupos controle e DTM, e na comparação intra-grupo de DTM, não houve diferença estatisticamente significativa. Entretanto, na condição clínica de lateralidade esquerda, não houve diferença estatisticamente significativa na comparação entre os grupos controle e DTM, e na comparação intra-grupo DTM. Na condição clínica de protrusão, na comparação entre os grupos controle e DTM, e na comparação intra-grupo de DTM, houve diferença estatisticamente significativa. Na condição clínica de apertamento de parafilme, houve diferença estatisticamente significativa na comparação entre os grupos controle e DTM, e não houve diferença significativa na comparação intra-grupo de DTM. Nas provas de mastigação de Bis e amendoim, houve diferença estatisticamente significativa na comparação entre os grupos controle e DTM, e não houve diferença estatisticamente significativa na comparação intra-grupo DTM. Para as provas de mastigação de chiclete e de parafilme, não houve diferença estatisticamente significativa na comparação entre os grupos controle e DTM, e na comparação intra-grupo DTM. Pode-se concluir que a atividade eletromiográfica dos músculos masseter e temporal do grupo DTM diminuiu ao final do tratamento com uso de placa oclusal por 60 dias, ao se avaliar as condições clínicas de repouso (exceto para o músculo masseter direito), lateralidade direita e esquerda (para todos músculos); e protrusão (exceto para o músculo masseter esquerdo). Verificouse esta mesma diminuição para o apertamento dental com parafilme. / In order to understand better the physiopathology that affects the muscles of the stomatognathic system, an electromyography analyses has been included in the studies. The electromyography (EMG) allows us to check and evaluate the muscle efficiency, in both sides of the body (symmetry) and between the muscle pairs as a possible effect of the lateral jaw deviation (torque) (Ferrario et al., 1999, 2002). The aim of this work was to study, by surface EMG, the masseter muscles (superficial part) and temporal (back part) in both sides, as well as verifying the effect of the resilient occlusal splint use, as a devise for the temporomandibular disorder treatment (TMDs), and also compare it with the control group. We studied 23 individuals with TMD signs and symptoms, clinically evaluated, who received the resilient occlusal splint use treatment. We used the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) in order to establish the presence or the absence of TMD; also it was registered an EMG activity of the masseter and temporal muscles, in both sides, before, (initial Step 1), 30 days (Step 2) and after 60 days of the resilient occlusal splint use (Step 3) (Pettengill et al., 1998); and relate the electromyography findings with the occlusion and stomatognathic functions clinic evaluation; compare the results of a population with TMD and the control group of 23 individuals. The EMG evaluation was registered through chewing movements and the rest clinic conditions, as well as bilateral laterality with contact, protrusion and tooth clench. The statistic analysis was done with the SPSS software version 15.0 (Chicago, IL, USA). Due to the fact that the hypothesis of the majority of the variable normality was rejected (Shapiro-Wilks Test) non-parametric methods were used in the analysis. The level of significance adopted p ≤0,05. The control group data and the TMD were compared by the non-parametric of Mann-Whitney test, and the intra-group comparisons TMD (initial, 30 and 60 days of splint use) were done with the non-parametric Wilcoxon test. According to the results in the rest clinic condition, there was no significant statistic difference between the control groups and TMD. It was seen a significant difference intra-group of TMD. There was a significant difference on the right laterality comparing both control groups and TMD, and there was no significant statistic difference in the intra-group comparison. Therefore, on the left laterality, we didnt find any significant difference between the control groups and the TMD either on the intra-group TMD comparison. We could find a quite significant difference between the protrusion clinic condition, in the comparison between the control groups and TMD, in the TMD intra-group comparison. Regarding the teeth clenching with parafilm clinic condition, there was a difference between the control groups and the TMD, but there was no difference between the TMD intra-group. The chewing test with Bis and peanuts, we could see a TMD group. We could see on the Bis test that there was a difference between the control group and the TMD, and there was no difference between the TMD intra-group. For the chewing gum test and of the parafilm, we didnt noticed difference between the control group, in the TMD and in the TMD intra-group. This way, we can conclude that the electromyography activity of the masseter and temporal muscles of the TMD group decreased at the end of the treatment with the use of the occlusal splint in 60 days, considering the rest clinic conditions (except for the right masseter muscle), right and left laterality (for all muscles), and protrusion (except for the left masseter muscle). It was verified the same decrease for the teeth clenching with parafilm.
93

Ajuste oclusal associado à terapia periodontal / Occlusal adjustment associated with periodontal therapy

Adriana Moura Foz 15 June 2012 (has links)
O ajuste oclusal (AO) como parte da terapia periodontal é um tema controverso, principalmente porque a literatura não fornece evidências suficientes sobre a influência do trauma de oclusão (TO) na doença periodontal (DP). A necessidade de ajuste oclusal na terapia periodontal é considerada incerta e requer investigação. O objetivo desta revisão sistemática foi identificar e analisar estudos que investigaram os efeitos do AO associado à terapia periodontal, sobre os parâmetros periodontais. Um protocolo foi desenvolvido incluindo todos os aspectos de uma revisão sistemática: estratégia de busca, critérios de seleção, seleção de métodos, coleta de dados e extração de dados. A pesquisa bibliográfica foi realizada utilizando MEDLINE via PubMed, Cochrane Central Register de estudos controlados e EMBASE. Os títulos e resumos de artigos foram selecionados de acordo com critérios estabelecidos na metodologia. Cada artigo que indicava uma possível correspondência com estes critérios, ou não poderia ser excluído baseado nas informações presentes no título ou no resumo, foi considerado e avaliado. Na seleção final, quatro artigos foram incluídos. Embora os estudos selecionados sugerem uma associação entre AO e uma melhora nos parâmetros periodontais, suas questões metodológicas (exploradas nesta revisão) sugerem a necessidade de novos estudos com maior qualidade. Atualmente as evidências presentes são insuficientes para presumir que AO é necessário para reduzir a progressão da doença periodontal. / Occlusal adjustment (OA) as part of periodontal therapy is a controversial theme, mostly because the literature does not provide enough evidence regarding the influence of trauma from occlusion (TO) on periodontitis. The need for occlusal adjustment in periodontal therapy is considered uncertain and requires investigation. The aim of this systematic review was to identify and analyze those studies that investigated the effects of OA, associated with periodontal therapy, on periodontal parameters. It was developed a protocol, which included all aspects of a systematic review: search strategy, selection criteria, selection methods, data collection and data extraction. A literature search was conducted using MEDLINE via PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE. Titles and abstracts of articles were selected according to established criteria. Every article that indicated a possible match, or could not be excluded based on the information given in the title or abstract, was considered and evaluated. On final selection, four articles were included. Although the selected studies suggest an association between OA and an improvement in periodontal parameters, their methodological issues (explored in this review) suggest the need for new trials of a higher quality. There is insufficient evidence at present to presume that OA is necessary to reduce the progression of periodontal disease.
94

Baropodometria dinâmica de atletas remadores, com sinais e sintomas de disfunção temporomandibular, pré e pós tratamento, com placa oclusal estabilizadora e exercício terapêutico de movimento mandibular: estudo piloto / Dynamic baropodometry in rowing athletes refering signs and symptoms of temporomandibular joint dysfunction before and after using an occlusal splint associated to therapeutic mandibular exercise: pilot study

Abe, Eduardo Yujiro 02 May 2016 (has links)
A desordem temporomadibular em atletas da modalidade do remo é uma temática ainda pouco abordada na literatura, muito embora se tenha conhecimento que a biomecânica do gesto esportivo possa provocar dores lombares, fratura de costela devido ao estresse, além de dores cervicais provenientes do desprendimento de força, para atingir grande velocidade e manutendo o equilíbrio por um longo tempo. O presente estudo tem como objetivo analisar, por meio da baropodometria dinâmica, a ação da placa oclusal estabilizadora associada ao exercício terapêutico de movimento mandibular em atletas remadores diagnosticados como portadores de desordem temporomandibular (DTM). Estudos prévios demonstram que um dispositivo intraoclusal (placa oclusal estabilizadora) tem ação significante sobre o sistema de manutenção do equilíbrio corporal na postura estática. Trinta indivíduos remadores apresentaram-se como voluntários com queixa de dor, sendo 10 deles (40% homens e 60% mulheres), com idade entre 24 e 35 anos foram diagnosticados com DTM por meio do preenchimento do questionário RDC/TMD e de exame clínico. O presente estudo piloto foi caracterizado por ser um ensaio clínico, randomizado, controlado, prospectivo e de intervenção. Imediatamente após aplicação do questionário e do exame clínico, todos os indivíduos realizaram testes de baropodometria estática e dinâmica. Após esta etapa, realizou-se a randomização dos grupos por meio de software online gratuito (www.random.org) que determinou os integrantes do grupo controle, denomindado de Grupo Exercício (GE) e grupo teste denominado de Grupo Placa (GP). Ambos os grupos receberam orientação para a realização do exercício terapeutico de movimento mandibular. Definidos os integrantes do GP, foram realizados agendamento para a realização da etapa de confecção da placa oclusal. Os grupos foram monitorados por 12 semanas e após este período foram reavaliados segundo os mesmos parâmetros da etapa inicial. A análise estatísitca foi realizada utilizando o modelo ANOVA (normalidade e homoscedasticiodade),teste T-Student e teste não paramétrico de Wilcoxon. Os resultados apresentaram significância estatística na redução da dor e aumento da amplitude articular da articulação temporomandibular (ATM) no GP (p<0,05). Não foi observada significância estatísitica na análise da pressão plantar dinâmica, justificado pelo fato da insuficiência do número de invidíduos da amostra. Concluiu-se que o uso da placa oclusal foi eficaz no tratamento da DTM pela redução do quadro doloroso, entretanto, uma amostragem maior se faz necessária pra a verificação da integração entre sistema estomatognático e postural na dinâmica da marcha. / Temporomadibular joint disorder (TMJD) in rower athletes has still few studies over this theme, where the biomechanics of athletic gesture points can produce low back pain, rib stress fractures and cervical pain as resulting from power requirement to obtain high speed and body balance for repeatedly long period exercises. The aim of this study was to analyze through dynamic plantar pressure the effects of occlusal splint and therapeutic exercise of mandibular movement in rowers diagnosed as suffering from TMJD. Previous studies have shown that the occlusal splint has significant action to keep the system of body balance in standing position. 30 rower athletes came as volunteers with pain symptoms, and 10 individuals, 40% men ande 60% women, aged between 24 and 35 years, were diagnosed with TMJD through completion of the RDC/TMD questionnaire and clinical examination. The research was performed by a randomized controlled prospective clinical study besides intervention. Immediately after the questionnaire application and clinical examination, all individuals performed tests of static and dynamic baropodometry. After this procedure, the groups were randomized by using a free online software (www.random.org) which determined the members of control group, named Exercise Group (EG) and test group called Oclusal Splint Group (OSG). Both groups received guidance for performing only therapeutic exercise of mandibular movement. The OSG were scheduled for the completion of preparation stage for occlusal splint. All groups were monitored for 12 weeks and after this period were evaluated according to the same parameters of the initial step. Statistic analysis was performed by using ANOVA model (normal and homoscedasticity), t-Student test and Wilcoxon nonparametric test. The results showed statistical significance to pain relief and increase of amplitude range of jaw joint in OSG (p < 0.05). No statistical significance was observed in the analysis of dynamic plantar pressure, justified by insufficient statistic population. In conclusion the use of occlusal splint was effective in the treatment of TMJD to pain relief, however, a larger sampling is necessary to verify the integration among stomatognatic system, posture and and gait dynamics analyzes.
95

Estudo do efeito da vibração no tratamento da disfunção temporomandibular através de um protótipo de placa vibratória oclusal / Study of the effectiveness of vibratory plate in the treatment of dysfunction temporomandibular

Luca, Carlos Eduardo Pitta de 13 December 2010 (has links)
Este estudo teve como objetivo estudar uma placa oclusalcom estimulação vibratória (POV) de base, para o tratamento da dor crônica miofascial. Foram selecionados 18 pacientes com mialgia crônica facial, de acordo com os Critérios para Diagnóstico em Pesquisa RDC . Os pacientes tinham entre 18 e 65 anos de idade, pertenciam ao sexo feminino e haviam usado placa estebilizadora acrílica por mais de 6 meses, e permaneciam com dor muscular. Foram excluídos pacientes com Disfunção Temporomandibular, que haviam feito uso de analgésicos ou de moduladores de sono, e pacientes desdentados parciais ou totais. A variável analisada foi a dor reportada pelos pacientes, usando a Escala Visual Analógica (EVA) de 100mm, medindo-se antes da instalação da POV, e um mes após o seu uso. Das 18 POV instaladas, 10 apresentaram falhas no mecanismo vibratório. As médias da EVA para os 8 pacientes que utilizaram a POV durante 1 mês foram de 56,62±22.82mm na aferição inicial e média de EVA final de 24,75±20,52mm, com p=0,011. Dos 8 pacientes apenas 4 concordaram com o uso da placa oclusal inativa (POI) por 30 dias, separadas por um período de wash-out de pelo menos 8 meses. Os níveis de dor da escala VAS foram a única variável analisada, e foram registrados antes e após o uso das placas. Foram utilizadas os testes t-teste pareado e ANOVA para medidas repetidas, para se obter os resultados estatísticos. No início do estudo, os níveis médios da VAS de dor antes de se utilizar a placa vibratória de maneira ativa e inativa foram 54,5±19,8 milímetros, e 44,0±13,6 milímetros, respectivamente. A comparação entre esses valores de referência não apresentaram diferença estatística (p> 0,05, teste t pareado). A variação média nos níveis de dor (VAS póspré) ao usar o mesmo tipo de placa, de maneira ativa e inativa foi de -42,0±-30,3 milímetros e 29,5±21,5 milímetros, e o t-teste revelou uma diferença significativa entre os dois grupos (p = 0,07). Foi feitauma nova análise, utilizando-se as mesmas medidas, através da Análise de Variância ANOVA, onde encontrou-se diferença estatisticamente significante (f(3,9)=7.543, p=0.008) antes do uso das placas ativas e das inativas. Entretanto, após o uso da correção com o teste de Bonferroni, foram encontrados resultados condizentes com aqueles obtidos na análise feita pelo programa do teste t. (p>0.05). Pode-se concluir que do uso da vibração como mecanismo de controle da DTM foi eficaz, mas a POV falhou na maioria dos casos devido a problemas mecânicos. / This study aimed to study an occlusal splint with vibratory stimulation (VibsS) as standard, for the treatment of chronic myofascial pain. Were selected 18 patients with chronic facial myalgia, according to the Research Diagnostic Criteria for Temporomandibular Disorders, RDC-TMD.The patients were between 18 and 65years old, female, using stabilization splints for more than six months, and that remained with muscle pain. Were excluded patients with Temporomandibular Disorders, which had made use of analgesics or sleeps modulators and those who were partially or totally edentulous. The analyzed variable was pain reported by patients using visual analog scale (VAS) of 100mm, measuring before the installation of VibsS, and one month after its use. Were installed 18 VibsS; 10 failures in the vibrating mechanism.The mean VAS for the 8 patients who used the VibsS for 1 month were 56.62 ± 22.82mm to measure initial and final mean VAS of 24.75 ± 20.52 mm, p = 0.011. From these 8 patients, only four agreed to the use of an occlusal splints inactive for 30 days, separated by a wash-out period of at least 8 months. The levels of pain-VAS score was the only variable analyzed, and were recorded before and after use of the splints. Were used paired t-tests and ANOVA for repeated measures to obtain the statistics. At baseline, mean levels of VAS pain before using the vibrating splint active and inactive were 54.5±19.8 mm, and 44.0±13.6 mm, respectively. The comparison of these reference values showed no statistical difference (p> 0.05, paired t-test). The average change in pain levels (VAS post-pre) when using the same type of analysis, with active and inactive splints was -42.0±- 30.3 and 29.5 mm±21.5 mm, and the t-test showed a significant difference between the two groups (p = 0.07). After that, was made, a new analysis, using the same measures through the analysis of variance ANOVA, where were found a statistically significant difference (f (3,9) = 7543, p = 0.008) before the use of active boards and inactive. However, after using the correction with the Bonferroni test, we found results consistent with those obtained in the analysis performed by the test program t. (p>0.05). Conclusion: This study showed that is an effective use of vibration as a control mechanism of TMD, but this VibsS failed in most cases due to mechanical problems.
96

Esthetics and Smile Characteristics Evaluated by Laypersons: A comparison of Canadian and US data

McLeod, Catherine E. 25 June 2010 (has links)
Objective: To collect data regarding Canadian laypersons perceptions of smile esthetics and compare these data to US data in order to evaluate cultural differences. Methods: Using Adobe® Photoshop® 7, a digital image of a posed smile of a sexually ambiguous lower face was prepared so that hard and soft tissue could be manipulated to alter Buccal Corridor (BC), Gingival display (GD), Occlusal Cant (OC), Maxillary Midline to Face Discrepancy (MMFD) and Lateral Central Gingival Discrepancy (LCGD). Adult Canadian laypersons (n=103) completed an interactive computer-based survey of 29 randomized images to compare smile preferences for these variable. The custom survey was developed to display fluid, continuously appearing modifiable smile variables using MATLAB® R2008 for presentation. These data were compared to previously published data for US laypersons. Statistical inference was determined using Wilcoxon Rank Sum tests. Results: Canadian laypersons were more sensitive in detecting deviations from ideal and had a narrower range of acceptability thresholds for BC, GD, OC, MMFD and LCGD. Ideal esthetic values were significantly different only for BC. Conclusions: It appears cultural differences do exist related to smile characteristics. Clinically significant differences in the preference of the smile characteristics were found between Canadian and US laypersons. Canadian laypersons, on average, were more discriminating to deviations from ideal and had a narrower range of acceptability.
97

Esthetics and Smile Characteristics Evaluated by Laypersons: A comparison of Canadian and US data

McLeod, Catherine E. 25 June 2010 (has links)
Objective: To collect data regarding Canadian laypersons perceptions of smile esthetics and compare these data to US data in order to evaluate cultural differences. Methods: Using Adobe® Photoshop® 7, a digital image of a posed smile of a sexually ambiguous lower face was prepared so that hard and soft tissue could be manipulated to alter Buccal Corridor (BC), Gingival display (GD), Occlusal Cant (OC), Maxillary Midline to Face Discrepancy (MMFD) and Lateral Central Gingival Discrepancy (LCGD). Adult Canadian laypersons (n=103) completed an interactive computer-based survey of 29 randomized images to compare smile preferences for these variable. The custom survey was developed to display fluid, continuously appearing modifiable smile variables using MATLAB® R2008 for presentation. These data were compared to previously published data for US laypersons. Statistical inference was determined using Wilcoxon Rank Sum tests. Results: Canadian laypersons were more sensitive in detecting deviations from ideal and had a narrower range of acceptability thresholds for BC, GD, OC, MMFD and LCGD. Ideal esthetic values were significantly different only for BC. Conclusions: It appears cultural differences do exist related to smile characteristics. Clinically significant differences in the preference of the smile characteristics were found between Canadian and US laypersons. Canadian laypersons, on average, were more discriminating to deviations from ideal and had a narrower range of acceptability.
98

Avaliação comparativa da efetividade das placas oclusais confeccionadas em relação central ou máxima intercuspidação em pacientes com DTM

Hamata, Marcelo Matida [UNESP] 16 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-16Bitstream added on 2014-06-13T18:35:13Z : No. of bitstreams: 1 hamata_mm_me_araca.pdf: 1154614 bytes, checksum: aeddf157add6e91da7b73e35970a0b5f (MD5) / A posição de relação central (RC) para a confecção de placas oclusais é muito discutível. Dessa forma, quando existe estabilidade oclusal, a máxima intercuspidação (MI) poderia ser utilizada como ponto de referência, eliminando a necessidade de registro interoclusal. O presente trabalho tem por objetivo comparar a efetividade de placas oclusais confeccionadas a partir de modelos articulados nessas duas posições. Para isso, 20 pacientes com desordens temporomandibulares (DTM) e dor de origem muscular foram divididos em dois grupos de 10 e tratados com placas confeccionadas nas posições de MI ou RC. Estes foram avaliados por meio de exame clínico, eletrognatográfico e eletromiográfico, antes e após três meses de terapia. Os resultados permitiram verificar que os dois tipos de placa atuaram de forma semelhante. Entretanto, a confecção de placas oclusais a partir da MI mostrou ser uma técnica mais fácil e menos onerosa do que a de RC. / Centric relation (CR) position to fabricate occlusal splints is very discussable. In this way, when there is occlusal stability, intercuspal position (IP) could be used as a reference point, eliminating the interocculsal record necessity. The purpose of the present study was to compare the effectiveness of occlusal splints fabricated from models articulated in these two positions. Twenty patients with temporomandibular disorders (TMD) of myogenous origin were divided in two groups with 10 each, which were treated with splints fabricated in the CR or IP. The patients were evaluated by clinical, electrognathographic and electromyographic examinations, before and tree months after the therapy. Results showed similar levels of effectiveness of both kinds of splint. However, the fabrication of the splints from IP technique is easier and less onerous than the CR.
99

O efeito da espessura da placa interoclusal sobre a atividade elétrica e a temperatura dos músculos temporal anterior e masseter durante o repouso e o apertamento dental

Pita, Murillo Sucena [UNESP] 16 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-16Bitstream added on 2014-06-13T18:35:14Z : No. of bitstreams: 1 pita_ms_me_araca.pdf: 1127223 bytes, checksum: 58ceb27b15fa47637a76872acfa04d3e (MD5) / O aumento da atividade muscular, induzido pelo apertamento dental, pode ser considerado como fator etiológico ou agravante das desordens temporomandibulares (DTMs), e essa atividade tem sido explorada de maneira direta através da eletromiografia e indiretamente pela variação da temperatura superficial cutânea sobre os músculos mastigatórios. As placas oclusais são os métodos não-invasivos mais utilizados para o tratamento das DTMs, particularmente as que afetam os músculos mastigatórios, objetivando a redução dessa hiperatividade muscular. Entretanto, há controvérsias em relação ao estabelecimento da sua espessura ideal. O objetivo do presente estudo, foi determinar o efeito da espessura de placas miorrelaxantes (3 mm e 6 mm) sobre a atividade elétrica e a temperatura dos músculos temporal anterior e masseter durante o repouso e o apertamento dental, considerando-se a condição assintomática de 20 indivíduos (10 homens e 10 mulheres) selecionados através do questionário Research Diagnostic Criteria (RDC). Os registros eletromiográficos foram realizados por meio do software “Bio EMG” (Biopack – System Bio-Research) e a temperatura das superfícies musculares realizada com o auxílio de um termômetro digital infravermelho (ICEL TD-971), com as respectivas medidas em microvolts ([V) e graus Celsius (ºC). Os resultados obtidos, analisados estatisticamente em um nível de 5% de significância (p<0,05), evidenciaram o aumento da atividade elétrica e a diminuição da temperatura dos músculos temporal anterior e masseter durante o apertamento dental em relação ao repouso. Entretanto não houve diferenças estatisticamente significativas em relação à atividade elétrica e a temperatura dos músculos mastigatórios entre as condições com e sem placa, entre o gênero masculino e feminino, bem como entre as espessuras de placas analisadas. / The increased of muscles activity, induced for dental clenching can be considered as causing or aggravating factor of temporomandibular disorders (TMD), and this activity has been exploited in a straightforward manner using electromyography and indirectly by the variation in skin surface temperature on the masticatory muscles. The occlusal splints are non-invasive methods more utilized for the treatment of TMD, particularly those from the masticatory muscles, aiming at the reduction of muscle hyperactivity. However, there are controversies regarding the establishment of their ideal thickness. The aim of this study was to determine the effect of thickness of the occlusal splints (3 mm and 6 mm) on the electrical activity and temperature of the anterior temporal and masseter muscles during dental clenching and resting, considering the asymptomatic condition of 20 individuals (10 males and 10 females) selected through the questionnaire Research Diagnostic Criteria (RDC). The electromyographic data were analyzed by the software Bio EMG (Biopack - Bio-Research System) and the surface temperatures of muscle carried out with the aid of a digital infrared thermometer (ICEL TD-971) and the corresponding measures in microvolts ([V) and degrees Celsius (ºC). The results, analyzed in a 5% of significance (p <0.05), showed increased electrical activity and lowering the temperature of the anterior temporal and masseter muscles during dental clenching in relation to the rest. However there were no statistically significant differences in relation to temperature and electrical activity of masticatory muscles between conditions with and without splints, between males and females, and between the thicknesses of occlusal splints analyzed.
100

ANÁLISE COMPARATIVA DO NÚMERO DE CONTATOS OCLUSAIS AO FINAL DA FASE DE CONTENÇÃO, E APÓS UM PERÍODO DE 5 ANOS, EM PACIENTES COM MÁ-OCLUSÃO DE CLASSE II, TRATADOS COM EXTRAÇÕES DE 4 PRÉ- MOLARES. / Comparative analysis of the number of occlusal contacts to the end of the retainer phase, and after a period of 5 years in patients with malocclusion of class II, treated with extrations to 4 bicuspid

Souza, Fernando Alcides José de 13 May 2007 (has links)
Made available in DSpace on 2016-08-03T16:31:07Z (GMT). No. of bitstreams: 1 Fernando Alcides.pdf: 377797 bytes, checksum: a4cdccf6daf88c5b970dcaea0e131aa8 (MD5) Previous issue date: 2007-05-13 / A study comparing the number of occlusal contact points in maximum habitual intercuspation in a sample composed by 14 leucoderm patients, 9 female and 5 males, Angle Class II division 1 mallocclusion, treated using Edgewise technique, with extrations of the 4 first pre-molars. These points were registered in two times: T1 at the end of superior retainer phase and T2 - after an average period of 5,2 years. The analysis verified the total points of contact of the upper and lower arches, separately. After the statistic analysis, it can be concluded that there were no significant differences between the average number of occlusal contacts in T1 and T2.(AU) / Realizou-se um estudo comparativo do número de pontos de contato oclusais na posição de máxima intercuspidação habitual em uma amostra composta por 14 pacientes leucodermas, sendo 9 do sexo feminino e 5 do sexo masculino, com máoclusão de Classe II, divisão 1a de Angle, tratados ortodonticamente pela técnica de Edgewise, com extrações dos 4 primeiros pré-molares. Estes pontos foram registrados em dois tempos: T1 - ao final da fase de contenção superior e T2 - após um período médio de 5,2 anos. A contagem dos contatos oclusais foram realizadas nos arcos superior e inferior, separadamente, para as regiões anterior e posteriores. Depois da análise estatística, pôde-se concluir que não houve diferença estatisticamente significante entre o número médio de contatos oclusais nos diferentes períodos estudados.(AU)

Page generated in 0.0674 seconds