• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 30
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 157
  • 55
  • 50
  • 47
  • 46
  • 39
  • 34
  • 29
  • 28
  • 28
  • 25
  • 21
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Effets d'un appareil d'avancement mandibulaire calibré sur le bruxisme relié au sommeil

Landry-Schönbeck, Anaïs January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
112

Stanovení nových referenčních hodnot maximálních inspiračních a expiračních tlaků a hodnot PO.1 u normální populace ve věkovém rozmezí 16 až 17 let / Definition of new referential values of maximum inspiratory and expiratory pressures and P0.1 values in normal population of the 16 - to - 17 age range

Kálalová, Tereza January 2014 (has links)
The purpose of this thesis is to define norms for inspiratory (Pimax) and expiratory (Pemax) pressures and mouth occlusion pressure (P0.1) in healthy white population of the 16-17 age group in the Czech Republic, specifically the capital city of Prague and its close vicinity. Furthermore, this work aspires to ascertain whether there is a correlation between the respiratory pressures, P0.1 and selected anthropometric and pulmonary values. In order to define the norms, 79 children were tested, including 41 boys and 38 girls 16 to 17 years old. After establishing the subjects' case histories, anthropometric, spirometric inspiratory, expiratory and forced vital capacity measurements were made. The study defined the norms of respiratory pressures and P0.1 in 16 to 17-year-old boys and girls, thus achieving its main goal. Furthermore, a difference was found between the average measured Pimax and Pemax values for boys and girls, with the boys showing higher values comparing with the girls. The study did not ascertain a correlation between respiratory pressures, P0.1 and selected anthropometric values (age, height, weight, BMI, BSA). No correlation was found between respiratory pressures and static pulmonary volumes. Powered by TCPDF (www.tcpdf.org)
113

Avaliação in vitro do efeito da aplicação de carregamento oclusal na qualidade marginal de restaurações cervicais em cavidades em forma de cunha / In viitro evaluation of the effects of occlusal loading on the marginal quality of cervical tooth restoration for wedge-shaped cavities

Francisconi, Luciana Fávaro 27 November 2008 (has links)
A abfração, uma das causas das lesões cervicais não cariosas, caracteriza-se pela perda de tecido mineralizado, em forma de cunha, próxima à junção cementoesmalte. Hipoteticamente, é o resultado de forças oclusais excêntricas aplicadas sobre os dentes. Essas lesões são freqüentemente restauradas para impedir sua progressão, para proteger e aumentar a resistência do remanescente dental, reduzir a hiperestesia dentinária e manter a saúde periodontal. Entretanto, pouco se sabe quanto ao efeito dos fatores causadores da abfração na qualidade marginal de restaurações cervicais, quando da reabilitação dessas lesões. Este estudo in vitro propõe-se, portanto, a analisar o efeito da aplicação de carga oclusal na qualidade marginal de restaurações de cavidades cervicais em forma de cunha, utilizando microscopia confocal de varredura a laser. Para tal, foram utilizados 40 dentes prémolares superiores humanos hígidos, extraídos, nos quais foram preparadas cavidades padronizadas em forma de cunha, em sua região cervical vestibular, por meio da utilização de pontas diamantadas cilíndricas de topo plano nº 3100 (1,6 mm de diâmetro e 21 mm de comprimento), posicionadas em 45º com a superfície mais plana e próxima à junção amelo-cementária. As cavidades (1,3 mm de profundidade, 2,3 mm de abertura ocluso-cervical, 4,0 mm de abertura mésio-distal, 1,6 mm de extensão na parede oclusal e 1,9 mm de extensão na parede cervical) foram restauradas com resina composta (Z250®) em associação ao uso de um sistema adesivo (Single Bond®). Para possibilitar a análise ao microscópio confocal, o sistema adesivo foi marcado previamente com adição de rodamina B. Após imersão em água deionizada, por 7 dias e polimento das restaurações, os espécimes foram incluídos em uma matriz de resina acrílica. A porção radicular de cada dente foi revestida com uma camada de poliéter (Impregum®), de aproximadamente 1 mm, a fim de simular o ligamento periodontal. A porção coronária foi mantida totalmente exposta ao meio externo. Os dentes foram, então, submetidos à ciclagem mecânica, pela ação de uma ponta metálica em forma de torpedo, exercendo carga de 150 N, num total de 106 ciclos. Para tanto, a ponta foi posicionada de acordo com as seguintes condições experimentais: sobre a vertente triturante interna da cúspide vestibular (GI; n=10); sobre o sulco central (GII; n=10); e sobre a vertente triturante interna da cúspide lingual (GIII; n=10). O grupo controle (GIV; n=10) não foi submetido à ciclagem mecânica, permanecendo apenas armazenado em água deionizada, a 37ºC, durante todo o período experimental. Finalizada a ciclagem mecânica, as superfícies vestibulares dentárias foram, então, recobertas com duas camadas do sistema adesivo (Single Bond®), agora marcado com fluoresceína, para delimitação dos possíveis defeitos formados. Os dentes foram seccionados longitudinalmente em duas metades (mesial e distal) e submetidos à avaliação em microscopia confocal, para análise da qualidade da margem das restaurações. Foi aplicado o teste do qui-quadrado (p<0,05) para as variáveis qualitativas presença ou ausência de fendas marginais e localização das fendas em relação às paredes cavitárias (oclusal, cervical ou ambas). Para as variáveis quantitativas (amplitude e extensão das fendas) aplicou-se o teste de Kruskal-Wallis (p<0,05). Os espécimes submetidos ao carregamento oclusal, independentemente do local de aplicação da força, apresentaram maior porcentagem de fendas marginais (53,33%) quando comparados aos espécimes do grupo controle (10%; p=0,016). Não houve diferença estatisticamente significante entre o local de aplicação de força oclusal tanto para a presença ou ausência de fendas marginais (p=0,875); como para a localização das fendas em relação às paredes cavitárias (p=0,270) ou mesmo para a extensão (p=0,190) e amplitude das mesmas (p=0,070). Conclui-se, portanto, que a aplicação de carga oclusal prejudicou o comportamento marginal de restaurações cervicais, mas a variação do local de incidência de carga não interferiu no comportamento marginal das mesmas. / Tooth abfraction, one of the causes of non carious cervical lesions, is a wedgeshaped tissue loss, situated next to the cement-enamel junction, being, hypothetically, the result of eccentric occlusal loads applied to the teeth. These lesions are often restored to avoid their progression, to protect and increase remnant tooth resistance, to reduce dental hypersensitivity and to maintain periodontal health. However, there is little knowledge about the effect of abfraction etiology factors on the restoration marginal quality in the rehabilitation of these lesions. This in vitro study intends, therefore, to analyze the effect of the application of occlusal load on the marginal quality of cervical restorations in wedge-shaped cavities, by employing laser scanning confocal microscopy. Standardized wedge-shaped cavities were prepared in the cervical buccal region of 40 sound extracted upper human premolars, by the use of a cylindrical diamond bur #3100 (1.6 mm in diameter and 21 mm in length), positioned in 45º with the surface that is plainer and closer to the cementenamel junction. The cavities (1.3 mm in depth, 2.3 mm in occluso-cervical opening, 4.0 mm in mesio-distal opening, 1.6 mm in occlusal wall length and 1.9 mm in cervical wall length) were filled with a composite resin (Z250®) associated with the use of an adhesive system (Single Bond®). For the analysis at the confocal microscope to be possible, the adhesive system was previously modified by the addition of rodhamine B. After storage in deionized water for 7 days, and after the finishing and polishing of the restorations, specimens were included in acrylic resin matrixes. The radicular portion of each tooth was covered by an approximately 1 mm layer of a polyether (Impregum®), for the creation of an artificial periodontal ligament. The crown portion was kept totally exposed to the external environment. Teeth were, then, submitted to the mechanical cycling, by the action of a torpedo-shaped tip that exerted a 150 N load for a total of 106 cycles. The tip was positioned according to the following experimental conditions: over the internal triturant vertent of the buccal cusp GI; n=10); over the centre of the fissure (GII; n=10); and over the internal triturant vertent of the lingual cusp (GIII; n=10). The control group (GIV; n=10) was not submitted to the mechanical cycling, staying only stored in deionized water, at 37oC, during the whole experimental period. When the mechanical cycling was over, buccal dental surfaces were, then, covered with two layers of the adhesive system (Single Bond®), now modified by the addition of fluorescein, for delimitation of the possible formed defects. Teeth were longitudinally sectioned into two halves (mesial and distal ones), and submitted to evaluation through confocal microscopy, for analysis of the restorations marginal quality. Chi-square test (p<0.05) was applied for evaluation of qualitative variables (presence or absence of marginal defects and their location according to the cavity walls occlusal, cervical or both); and Kruskal-Wallis test (p<0.05) was applied for evaluation of quantitative variables (length and width of the defects). Specimens submitted to occlusal loading, independently of the location of the tip, presented a higher percentage of marginal defects (53.33%), when compared to the control group (10%; p=0.016). There was no significant statistical difference among the local of load placement for the presence or absence of marginal defects (p=0.875); for their localization according to the cavity walls (p=0.270); or even for their length (p=0.190) and width (p=0.070). It can be concluded, therefore, that occlusal loading was harmful for the margins of cervical restorations; but the different local of its incidence did not interfere with their marginal quality.
114

Alterações das atividades eletromiográficas dos músculos masseter e temporal anterior após desprogramação neuromuscular da mandíbula de acordo com a filosofia de Roth / Changes of the electromyographics activities of the masseter and anterior temporal muscles after the mandibular neuromuscular deprogramming according to Roth’s philosophy

Santos, Helena Márcia Guerra dos 07 July 2006 (has links)
As atividades eletromiográficas dos músculos masseter e temporal anterior foram avaliadas em amostra constituída por 37 indivíduos assintomáticos, com maloclusão de Classe I divididos em dois grupos - Experimental e Controle. O grupo Experimental foi composto por 23 indivíduos, sendo 14 do gênero masculino e 9, do feminino, com média de idade de 23 anos e 7 meses, e foi submetido à desprogramação neuromuscular, com o uso de placa oclusal, pelo período médio de 6 meses e 3 dias. O grupo Controle foi formado por 14 indivíduos, sendo 11 do gênero feminino e 3, do masculino, com média de idade de 25 anos e 11 meses, e não fez uso de placa oclusal, nem foi submetido a qualquer intervenção oclusal, no período médio de observação de 8 meses e 10 dias. Os registros eletromiográficos foram realizados por meio de eletrodos bipolares de superfície durante o repouso mandibular e o apertamento oclusal máximo, em dois momentos - T1 e T2. Os valores obtidos foram mensurados pelo cálculo do \"Root Mean Square\" (RMS) e expressos em microvolts (&#956;V). Os índices de assimetria e atividade foram calculados em porcentagem (%). Os dados foram analisados estatisticamente por meio dos testes ANOVA e Bonferroni, considerando-se o nível de significância de 5%. Os resultados mostraram que no grupo Experimental, após o uso da placa oclusal, ocorreu redução significante das atividades eletromiográficas de repouso, assim como aumento significante da atividade eletromiográfica em apertamento oclusal máximo. O grupo controle não mostrou qualquer diferença estatisticamente significante entre os momentos. Os índices de assimetria mostraram que, no repouso mandibular, os músculos do lado esquerdo foram mais ativos. Os índices de atividade mostraram que o músculo temporal anterior apresenta maior contribuição relativa, quando comparado ao masseter, no repouso mandibular. Ambos os índices não sofreram alterações significantes entre os momentos estudados, nos dois grupos. / The electromyographic activity of the muscles masseter and temporal (anterior part) was evaluated in a sample of 37 asymptomatic subjects with Class II malocclusion. They were divided in two groups - experimental and control. The experimental group consisted of 23 subjects, 14 males and 9 females, mean age 23y 7m. This group was neuromuscularly deprogrammed with the use of occlusal splints during a mean period of 6 months and 3 days. The control group was formed by 14 individuals, 3 males and 11 females, mean age 25y 11m. This group did not wear occlusal splint nor suffered any occlusal intervention for a mean observation period of 8 months and 10 days. The electromyographic recordings were accomplished by means of surface bipolar electrodes. The recordings were taken at two different moments - T1 and T2, at mandibular rest position and maximal occlusal clenching. The obtained values were measured by the calculating \"Root Mean Square\" (RMS) and they were expressed in microvolts (&#1094;V). The asymmetry and activity indexes were calculated in percentage (%). The data was statistically evaluated by ANOVA and Bonferroni`s tests, considering the level of significance of 5%. The results showed that in the group that wore the occlusal splint occurred a significant reduction of the eletromyographics activities at rest position, as well as a significant increase of the electromyographics activities at maximal occlusal clenching. The control group did not show any significant change in the observated period. The asymmetry indexes showed at mandibular rest, that the left side muscles were more actives. The activity indexes also showed that the temporal muscle presents a relative greater contribution for the maintenance of the rest mandibular position. The indexes - asymmetry and activity - did not present significant changes between the moments for both groups.
115

"Avaliação da densidade óptica da sutura palatina mediana por meio do sistema de radiografia digital por placa fotoativada em pacientes submetidos a disjunção palatina" / "Evaluation of the optic density on the medium suture palatiny by means of digital x-ray system for plate fotoativada in patients submitted ti palatine disjunction"

Melo, Maria de Fatima Batista de 12 June 2003 (has links)
RESUMO A Expansão Rápida da Maxila é um recurso clínico adotado pelos ortodontistas no tratamento das más oclusões com deficiência transversa real ou relativa da maxila. Esta, inclui uma fase ativa, promovendo a desarticulação dos ossos maxilares por meio da sutura, e uma fase passiva, onde uma série de eventos levam à remodelação óssea e restauração da sutura, com o aumento clínico na largura do palato. Discute-se qual a melhor época para a disjunção e o tempo necessário para que haja a perfeita remodelação óssea. A radiografia oclusal assume aqui um importante papel, pois é por meio desta que se obtém a imagem da sutura palatina mediana permitindo uma análise descritiva de suas condições em todas as etapas do tratamento A nossa proposta no presente estudo, foi a de medir as densidades ópticas da sutura palatina mediana antes da disjunção (Fase I), imediatamente após a disjunção, (Fase II) e após contenção de três meses (Fase III), usando um sistema de imagem digital, comparando-as e correlacionando-as com a radiografia oclusal convencional. A amostra, constituída por 31 (trinta e um) pacientes que se submeteriam à disjunção palatina e que se encontravam em fase de crescimento, foi dividida em:grupo I, constituído pelos pacientes de dentadura mista e grupo II, pelos pacientes de dentadura permanente. Foram obtidas radiografias oclusais e imagens digitais nas fases Fase I, Fase II e na Fase III. Áreas de interesse foram demarcadas nas radiografias digitais, procedendo-se a leitura das densidades ópticas pelo programa Digora for Windows-2.1, e comparando os resultados entre si e com a avaliação subjetiva feita nas radiografias oclusais. Após a análise dos dados pelo teste t de Student pareado, pode-se concluir que 1) as densidades ópticas da sutura palatina mediana na fase final, mostram valores inferiores aos da fase inicial nos pacientes do grupo I; 2) as densidades ópticas da sutura palatina mediana na fase final, mostram valores semelhantes aos da fase inicial nos pacientes do grupo II; 3) as densidades ópticas finais da sutura palatina mediana não correspondem às iniciais nos pacientes do sexo feminino do grupo I; 4) as densidades ópticas finais da sutura palatina mediana são semelhantes às iniciais nos pacientes do sexo masculino do grupo II; 5) para os pacientes do grupo II não houve diferença significante entre os valores de densidade óptica inicial e final, tanto no sexo masculino como feminino; 6) os resultados encontrados nas imagens digitais são compatíveis com os encontrados nas radiografias oclusais convencionais. / SUMMARY The Fast Expansion of the Jaw is a clinical resource adopted by the ortodontists in the treatment of the bad occlusions with real or relative deficiency transversal, of the jaw. This, includes a phase, promoting the disarticulation of the maxilarys bones by means of the suture, and a passive phase, where a series of events takes to the bone remodelling and restoration of the suture, with the clinical increase in the width of the palate. The best time for the disjunction and the necessary time is argued which so that it has the perfect bone remodelling. The oclusal radiography assumes an important role here, therefore it is for way of this that if gets the image of the medium palatine suture allowing to a descriptive analysis of its conditions in all the stages of the treatment our proposal in the present study, was to measure the optic densities of the medium palatine suture before the disjunction (Phase I), immediately after the disjunction, (Phase II) and after containment three months (Phase III), using a system of digital image, comparing and correlating them with the conventional oclusal radiography. The sample, consisting of 31 (thirty one) patient that would submitted the palatine disjunction and that found in growth phase, divided in Grave I, constituted of the patients of mixing set of teeth and group II, for the permanent set of teeth patients. Oclusal radiography and digital images in the phases had been gotten Phase I, Phase II and in Phase III. Areas of interest had been demarcated in the digital x-rays, proceeding it reading from the optic densities for the Digora program for Windows-2.1, and comparing the results among themselves. With the subjective evaluation in the oclusal radiographies.(After the analysis of the data by student T test could be concluded that1) the opitic densities of the medium palatine suture in the final phase, show inferior values to the ones of the initial phase in the patients of group I;2) the optic densities of the medium palatine suture in the final phase, show similar values to the ones of the initial phase in the patients of group II;3) the final optic densities of the medium palatine suture do not correspond to the initials in the patients of the female groupI;4) the final opitic densities of the medium palatine suture are similar to the initials in the patients of the male group II;5) for the patients of group II it did not have significant difference betweenthe values of initial and final opitic density, as much in the male and female groups6) the results found in the digital images are compatible wit those found in the conventional oclusal radiographics.
116

Aplicação do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico / Applications of Farc Protocol of TMD treatment with occlusal splint and electromuographic control

Silva, Carolina Amorim Vieira e 10 January 2008 (has links)
A eletromiografia de superfície (EMG) pode ser considerada atualmente um instrumento muito útil, que permite a avaliação quantitativa da musculatura de pacientes com desordem temporomandibular (DTM). O propósito do presente estudo foi aplicar e analisar os efeitos do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico, comparando os dados da avaliação, de 15 pacientes com DTM, classificados segundo o RDC / TMD, antes e após o tratamento; os resultados da EMG obtidos antes, durante e após o uso da placa por 45 dias, pelo grupo com DTM; e comparando os resultados da EMG de uma população com DTM antes e após o tratamento com placa, com um grupo controle. O exame eletromiográfico dos músculos masseter e temporal anterior foi realizado na primeira sessão de avaliação (Etapa 1), após 1 semana (Etapa 2) e após 5 semanas (Etapa 3) de tratamento, servindo para verificar a estabilidade da placa e a evolução da atividade muscular. As ondas da EMG foram analisadas, por meio do software, e os seguintes índices de EMG foram computados: coeficiente de porcentagem de sobreposição (POC) dos músculos masseter e temporal; coeficiente de torque (TORS); índice de assimetria (ASIM), índice de atividade (ATTIV) e o total da atividade elétrica (IMP). Para os dados expressos em nível intervalar de mensuração, foi empregada estatística não-paramétrica, sendo empregado o teste de Wilcoxon para dados pareados nas análises intra-grupo (entre as etapas). Os dados em nível de razão, foram analisados por meio de estatística paramétrica, sendo empregados para as análises intra-grupo o teste t para dados pareados, para as análises entre grupos o teste t para amostras independentes. O nível de significância estabelecido foi de 5%. Após o tratamento, foi encontrada diferença estatística na capacidade de abertura da boca, assim como na remissão da dor a palpação de grande parte da musculatura avaliada e na ATM. Foi obtida diferença significante no valor de POC do masseter e de IMP, imediatamente após o primeiro ajuste da placa. Quando comparada a etapa 1, sem a placa, com a etapa 2, com a placa ajustada, foi obtida diferença significante nos valores de POC do masseter, de ASIM e de IMP. Houve diferença significante entre as etapas 1, sem placa, e a etapa 3, com placa, nos valores de POC dos músculos masseter e temporal, de ASIM, ATTIV e IMP. Durante todo o tratamento não houve diferença significativa nos índices de EMG dos exames realizados sem a placa. Houve diferença estatística entre os grupos DTM e controle no início e ao final do tratamento, sendo observada diferença significante nos valores de EMG para POC de ambos os músculos e ATTIV. A placa oclusal, embora não tenha mostrado mudanças permanentes, mostrou ser efetiva para promover equilíbrio das atividades da EMG durante seu uso, e eficiente no alívio dos sintomas. Os parâmetros de pesquisa com EMG permitiram seu uso no âmbito cientifico na identificação do desequilíbrio neuromuscular, desta forma este instrumento de avaliação permitiu analisar e avaliar de forma objetiva as diferentes etapas de um tratamento tradicional para DTM na prática odontológica e diferenciar pacientes com DTM de indivíduos assintomáticos. / Surface electromyography (EMG) can currently be considered a very useful instrument which allows a quantitative assessment of masticatory muscles in patients with temporomandibular dysfunction (TMD). The purposes of this study was to apply FARC Protocol of TMD treatment with occlusal splint and electromyographic control, correlating the clinical assessment data before and after the treatment with an occlusal splint for a group of 15 patients with TMD, classified according to the RDC / TMD; comparing the results obtained with EMG, before and after treatment with an occlusal splint; comparing the EMG results for this group suffering from TMD and an asymptomatic control group. The electromyographic examination of the masseter and the anterior temporal muscles was carried out in the first assessment session (Phase 1), after one week (Phase 2) and after five weeks (Phase 3) of treatment, aiming at verifying the stability of the splint and the evolution of the muscular activity. The EMG waves were analyzed using the software, and the following EMG indices were calculated: percentage overlapping coefficient (POC) of the masseter and anterior temporal muscles; torque coefficient (TORS); asymmetry index (ASIM); activity index (ATTIV) and the total electrical activity (IMP). For data expressed at measurement interval levels, nonparametric statistics were adopted, using the Wilcoxon test for the paired data in the intra-group analysis (among the phases). Data at ratio level were analyzed through parametric statistical means: paired data t test for intra-group analysis, independent sample t test for among-group analysis. The significance level was established at 5%. After treatment, a statistical significance was found in mouth opening, as well as in the remission in the pain at palpation of a significant portion of the assessed muscles and the TMJ. A significant difference was obtained for the masseter POC and IMP, immediately after the first splint adjustment. When comparing the first phase, without the splint, to the second phase, with the first splint adjustment, a significant difference was observed in the values for masseter POC, ASIM and IMP. There was a significant difference between phase 1, without the splint, and phase 3, with the adjusted splint, for masseter and temporal POC values, ASIM, ATTIV, and IMP. Throughout the entire treatment, there were no significant differences concerning the EMG index in the examinations performed without the splint. There was a statistical significance between the TMD and the control groups in the beginning and in the end of the treatment, with significant differences observed in POC values for both muscles and ATTIV. The occlusal splint, without provoking permanent changes, proved effective to promote the balance of electromyographic activities during its use, and efficient in relieving the symptoms. The EMG parameters allow its scientific use in identifying neuromuscular unbalance, and as such, this assessment tool allowed an objective analysis and evaluation of the different phases of the traditional treatment for TMD in dentistry, differentiating patients with TMD and asymptomatic individuals.
117

"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica" / Biomechanics load transmission single implants according to prosthetic materials photoelastic and dinamic analysis

Markarian, Roberto Adrian 13 June 2005 (has links)
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso na literatura sobre a sua efetividade. O objetivo deste trabalho foi comparar, por análise fotoelástica e dinâmica, a transmissão de forças após a ação de cargas sobre próteses unitárias sobre implantes em função dos materiais protéticos. Confeccionou-se um modelo em resina fotoelástica com anatomia semelhante à região de pré-molares inferiores, contendo um implante de hexágono interno de 3,75 x 11,5 mm. Foram elaboradas três tipos de próteses em materiais com rigidez decrescente: 1- Metálica (alta rigidez); 2- Resina composta (rigidez moderada), 3- Com um disco de EVA interposto com h=2,5 mm (baixa rigidez). Por meio de um polariscópio circular, observou-se qualitativamente a tensão gerada no modelo durante a aplicação de forças axiais de 100 N, em regime compressivo, sobre cada tipo de prótese. Para a análise dinâmica, realizou-se um modelamento físico de cada um dos três sistemas implante-prótese com modelos de Voigt. A partir daí, uma representação matemática dos sistemas foi deduzida e resolvida, levando em consideração as propriedades mecânicas dos diferentes materiais testados, como o módulo de elasticidade (E), o coeficiente elástico (k) e a constante de amortecimento (c). Para representar uma carga mastigatória fisiológica, foi aplicado um pulso de força senoidal com duração de 0,25 s e intensidade máxima de 100 N, segundo a expressão ()) 8 cos( . 50 50 t t f &#960; &#8722;=. Observou-se na análise fotoelástica que após a aplicação de 100N, surgiram tensões na região apical e na cervical dos implantes, com intensidade e localização similares entre os três tipos de prótese. A análise dinâmica mostrou que a força de 100N aplicada na prótese é totalmente transmitida ao implante instantaneamente. Os resultados das análises concordam entre si e mostram que não é possível amortecer as forças mastigatórias por meio dos materiais oclusais. / Less rigid oclusal materials such as acrylic resins are often used in prosthesis over implants because they are supposed to diminish the loads transferred to the bone; however there is no scientific evidence to support this theory. The objective of this work was to compare by photoelastic and dynamic analysis the load transfer after oclusal loads over single prosthesis over implants, varying the oclusal materials. A photoelastic model was created, with an anatomy similar to an inferior premolar region. An internal hexagon implant (3,75 x 11,5 mm) was put in this model. Three different types of prosthesis were constructed with decrescent stiffness: 1- Metallic (higher stiffness); 2- Composite resin (moderate stiffness); 3- With an EVA disc interposed (fewer stiffness). By means of a circular polariscope, the stress generated in the model with a compressive axial load of 100 N, was observed for each prosthesis. For the dynamic analysis, a physical modeling of each implant-prosthesis was carried out with Voigt models. After that, a mathematical representation of the systems was deduced and solved, taking into account the mechanic properties of the different materials, like the elastic modulus (E), the elastic coefficient (k) and the damping constant (c). To represent a physiologic masticatory load, a senoidal force was applied, during 0,25 s and maximum load of 100 N, by the expression ()) 8 cos( . 50 50 t t f &#960; &#8722;=. With the photoelastic analysis, it was observed that stresses were generated at the apical and cervical regions of implants, with similar intensity and patterns between the three types of prosthesis. The dynamic analysis, showed that the loads applied over the prosthesis are transferred to the implant instantaneously. The results of both anaylis are in agreement that it is not possible to damp masticatory loads by means of occlusal materials.
118

Levantamento epidemiológico de fatores relacionados com a má oclusão em crianças de 3 a 9 anos de idade no Equador / Epidemiological survey of related factors with malocclusion in children from 3 to 9 years of age in Ecuador

Angulo, Nilda Eugenia Navarrete 29 August 2018 (has links)
É muito importante que se reconheça os fatores relacionados com à má oclusão que ocorrem em uma determinada população à fim de que medidas preventivas e tratamentos ortodônticos possam ser conduzidos. O objetivo do presente estudo epidemiológico foi obter dados representativos sobre fatores relacionados com as más oclusões na dentição decídua e mista no Equador. Os responsáveis por 400 crianças, de 3 a 9 anos, em atendimento na Faculdade de Odontologia da Universidade Central do Equador foram questionados, incialmente, quanto aos dados pessoais, histórico familiar e saúde. Em sequência as crianças foram examinadas, clinicamente, extra e intra oralmente. O exame funcional, avaliação de hábitos e nível socioeconômico também foram conduzidos por um único avaliador. Os dados obtidos foram tabulados para se obter tabelas de frequência e porcentagem. Foi aplicado o Teste Qui quadrado ou Teste de Fisher (p<0,05). Um número maior de crianças com má oclusão (77%) foi encontrado do que crianças com oclusão adequada (p=0,00001). Não se pode afirmar que houve correlação significativa entre classe socioeconômica e má oclusão (p=0,12). Houve predomínio do hábito de morder objetos estranhos e onicofagia. 33,33% das crianças com mordida aberta apresentavam respiração bucal, no entanto, entre as crianças que apresentaram outros tipos de oclusão, 32,47% tinham respiração bucal. A sucção digital foi encontrada em 14% das crianças. Conclui-se que existe um número significante de má oclusão; há correlação entre interferências oclusais e a presença de mordida cruzada; a atrição fisiológica desenvolve-se com o avanço da idade; não houve associação significativa entre respiração bucal e mordida aberta e o nível sócio econômico não interfere nas características de oclusão. / It is very important to recognize the factors related to bad occlusion that occur in a certain population so that the measures Preventive and orthodontic treatments can be carried out. The objective of the present epidemiological study was to obtain representative data on factors related to malocclusions in deciduous and mixed dentition in Ecuador. Those responsible for 400 children, from 3 to 9 years old, in care in School of Dentistry of the Central University of Ecuador were respondents, in terms of personal data, family history and Health. In sequence the children were examined, clinically, extra and intra orally. Functional examination, evaluation of habits and socioeconomic status They were conducted by a single researcher. The data They were tabulated to obtain frequency and percentage tables. The application was applied Chi square test or Fisher\'s test (p <0.05). A greater number of Children with malocclusion (77%) were found to be children with correct occlusion (p = 0.00001). It cannot be said that there was significant correlation between socioeconomic class and bad occlusion (p = 0.12). A predominance was observed the habit of biting foreign objects and Onychophagia. 33.33% of children with open bite had mouth breathing, however, among children who presented other types of occlusion, 32.47% had mouth breathing. The digital suction 14% of children were found. It is concluded that there is a significant number of malocclusion; there is correlation between occlusal interferences and the presence of a crossbite; Physiological attrition develops as Age advances; there was no significant association between mouth breathing and open bite and socioeconomic status does not interfere with the characteristics of occlusion.
119

Qualidade marginal de restaurações cervicais, feitas com materiais de diferentes módulos de elasticidade, em pré-molares submetidos a carregamento oclusal excêntrico / Marginal quality of cervical restorations, made with materials of different moduli of elasticity, in premolars subject to eccentric occlusal loading

Anhesini, Brunna Haddad 01 July 2016 (has links)
Os materiais restauradores utilizados na região cervical dos dentes podem ser afetados por resultantes de forças oclusais excêntricas, que já podem ter contribuído à formação da lesão, e deveriam ser capazes de resistir às tensões. Não há consenso, porém, quanto ao papel de diferentes materiais, quiçá especialmente no tocante a seus módulos de elasticidade, no sucesso das respectivas restaurações. Avaliou-se, pois, a influência do uso desses materiais, com módulos de elasticidade (E) distintos em essência, e da associação entre eles, na qualidade marginal de restaurações cervicais em pré-molares submetidos a carregamento oclusal excêntrico. Cavidades cervicais em forma de cunha, preparadas em pré-molares unirradiculares superiores humanos, hígidos e extraídos, foram restauradas com uma resina composta (RC: Z250 XT, n=20); com a resina em associação a um ionômero modificado por resina para forramento (Mista/M: Vitrebond, n=20); ou com um ionômero modificado por resina para restauração (CIV: Vitremer, n=20). Metade dos dentes de cada grupo foi submetida a carregamento oclusal excêntrico (coe: inclusão em resina acrílica e ligamento periodontal artificial, 150 N, 106 ciclos, 2,5 Hz), e a outra metade, apenas armazenada por período de tempo equivalente (Controle/c: água destilada, 37º C). Um sistema adesivo marcado por fluoresceína foi utilizado para delimitação dos defeitos formados, que foram avaliados por meio de Microscopia Confocal de Varredura a Laser. Para a presença ou ausência de fendas marginais aplicou-se, num contexto geral, para cada fator em estudo (carregamento oclusal excêntrico - coe / c; material restaurador - RC / M / CIV), o teste do qui-quadrado (?=0,05). Em específico, aplicaram-se, individualmente, em cada nível do fator carregamento oclusal excêntrico, e em cada nível do fator material restaurador, respectivamente, o teste do qui-quadrado e o teste exato de Fisher (?=0,05). Para a localização das fendas em relação às paredes cavitárias (O: oclusal / C: cervical / OC: ambas) aplicou-se, para cada fator em estudo, o teste do qui-quadrado (?=0,05). O teste de Mann-Whitney foi aplicado para a largura e a profundidade das fendas marginais, para comparar os diferentes níveis do fator carregamento oclusal excêntrico, e o teste de Kruskal-Wallis, para comparar os diferentes níveis do fator material restaurador (?=0,05). Numa conjuntura abrangente, nenhum dos fatores associou-se significativamente com as variáveis de resposta qualitativas nominais ou exerceu influência sobre as quantitativas. Mais especificamente, por exclusivo quando da aplicação do carregamento oclusal excêntrico, o uso dos diferentes materiais restauradores associou-se significativamente com a frequência de fendas marginais (RC>M>CIV). Ainda que a qualidade marginal de restaurações cervicais possa não ser influenciada, de maneira geral, pelo carregamento oclusal ou pelo uso de diferentes materiais, inclusive em associação, o aspecto desfavorável do emprego da resina composta pode tornar-se relevante, em particular, quando da existência de carga oclusal excêntrica. / Restorative materials used in the cervical region of teeth may be impacted by resultants of eccentric occlusal loads that have already contributed to the formation of the lesion, and should be capable of withstanding the stresses. There is no consensus, however, about the role of different materials, maybe especially regarding their moduli of elasticity, in the success of respective restorations. The influence of the use of these materials, with different moduli of elasticity (E) in essence, and of their association, on marginal quality of cervical restorations in premolars subjected to eccentric occlusal loading was evaluated thus. Cervical wedge-shaped cavities, prepared in human upper single-rooted premolars, healthy and extracted, were restored with a resin composite (RC: Z250 XT, n=20); with the composite in combination with a resin-modified lining ionomer (Mixed/M: Vitrebond, n=20), or with a resin-modified restorative ionomer (GIC: Vitremer, n=20). Half of the teeth of each group was subjected to eccentric occlusal loading (eol: embedment in acrylic resin, artificial periodontal ligament, 150 N, 106 cycles, 2.5 Hz), and the other, only stored for an equivalent period of time (Control/c: distilled water, 37°C). A fluorescein-marked adhesive system was used for delimitation of formed defects, which were evaluated by means of Laser Scanning Confocal Microscopy. For the presence or absence of marginal gaps, in a general context and for each factor under study (eccentric occlusal loading - eol / c; restorative material - RC / M / GIC), chi-square test was applied (?=0.05). In specific, individually, at each level of the factor eccentric occlusal loading, and at each level of the factor restorative material, chi-square test and Fisher\'s exact test were respectively applied (?=0.05). For the location of the gaps in relation to the cavity walls (O: occlusal / C: cervical / OC: both), for each factor under study, chi-square test was applied (?=0.05). The Mann-Whitney test was applied to the width and depth of marginal gaps, to compare the different levels of the factor eccentric occlusal loading, and the Kruskal-Wallis test, to compare the different levels of the factor restorative material (?=0.05). In a comprehensive view, none of the factors was significantly associated with qualitative response variables or wielded any influence on the quantitative ones. More specifically, for exclusive when eccentric occlusal loading was applied, the use of the different restorative materials was significantly associated with the frequency of marginal gaps (RC>M>GIC). Though marginal quality of cervical restorations may not be in general influenced by the occlusal loading or the use of different materials, even in association, the unfavorable aspect of the use of the resin composite may become relevant particularly in face of the existence of eccentric occlusal load.
120

Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splints

Soares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.

Page generated in 0.0375 seconds