• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 30
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 157
  • 55
  • 50
  • 47
  • 46
  • 39
  • 34
  • 29
  • 28
  • 28
  • 25
  • 21
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

CAD/CAM monolithic materials : wear resistance and abrasiveness, and the effect of grinding and polishing on their roughness and fracture resistance. /

Ludovichetti, Francesco Saverio January 2019 (has links)
Orientador: Renata Garcia Fonseca / Resumo: Esta tese consiste em dois estudos, ambos investigando materiais monolíticos fresados por tecnologia CAD-CAM. Primeiro estudo. Objetivo. A resistência ao desgaste e abrasividade do Lava Ultimate, Vita Enamic, Vita Suprinity, IPS e.max CAD e Lava Plus, bem como algumas propriedades que podem estar relacionadas, foram analisadas. Métodos. Espécimes desses materiais tiveram sua rugosidade, dureza e coeficiente de atrito avaliados, respectivamente, em microscópio confocal, microdurômetro e tribômetro. O teste de desgaste conhecido como "2-body", no qual os materiais atuaram como abrasivos e, juntamente com o esmalte bovino, também como antagonistas, também foi realizado. A taxa de desgaste foi determinada com perfilômetro de superfície e as superfícies desgastadas foram observadas por microscopia eletrônica de varredura (MEV). Resultados. Vita Enamic e Lava Ultimate mostraram a maior rugosidade, enquanto IPS e.max CAD e Vita Suprinity, a menor. O resultado da dureza foi Lava Plus> (Vita Suprinity = IPS e.max CAD)> Vita Enamic> Lava Ultimate. O Lava Ultimate exibiu maior coeficiente de atrito do que o IPS e.max CAD e o Lava Plus. O Lava Plus e o IPS e.max CAD mostraram um potencial significativamente maior para desgastar o Lava Ultimate. Estes dois materiais, juntamente com o Vita Suprinity, foram os que mais desgastaram o esmalte e o Vita Enamic. Vita Suprinity e IPS e.max CAD promoveram o maior desgaste do Lava Plus, e o inverso também ocorreu. Vita Enamic e Lava Ultimate causar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This thesis consists of two studies, both investigating the computer-aided design and computer-aided manufacturing (CAD-CAM) monolithic materials. First study. Aim. The wear resistance and abrasiveness of Lava Ultimate, Vita Enamic, Vita Suprinity, IPS e.max CAD, and Lava Plus, as well as some properties that might be related to, were analyzed. Methods. Specimens from these materials had their roughness, hardness, and coefficient of friction evaluated, respectively in confocal microscope, microdurometer, and tribometer. The 2-body wear test, wherein the materials acted as abraders and, together with bovine enamel, also as antagonists, was also carried out. The wear rate was determined with surface profilometer and the worn surfaces were observed by scanning electron microscopy (SEM). Results. Vita Enamic and Lava Ultimate showed the highest roughness, whereas IPS e.max CAD and Vita Suprinity, the lowest. The hardness result was Lava Plus > (Vita Suprinity=IPS e.max CAD) > Vita Enamic >Lava Ultimate. Lava Ultimate exhibited a higher coefficient of friction than IPS e.max CAD and Lava Plus. Lava Plus and IPS e.max CAD showed significantly higher potential to wear Lava Ultimate. These two materials, together with Vita Suprinity, provided the highest wear of enamel and Vita Enamic. Vita Suprinity and IPS e.max CAD exhibited the highest wear against Lava Plus, and the inverse also occurred. Vita Enamic and Lava Ultimate were among the materials that caused the lowest wear of ename... (Complete abstract click electronic access below) / Doutor
122

Avaliação da posição condilar em pacientes com DTM antes e após terapia com placa interoclusal estabilizadora por meio de tomografia computadorizada de feixes cônicos / Evaluation of condylar position in TMD patients before and after treatment with occlusal splints by cone beam computed tomography

Coelho Filho, Deícola 02 September 2014 (has links)
O objetivo deste estudo foi avaliar a posição condilar em pacientes com DTM articular antes e após tratamento com placa interoclusal estabilizadora por meio de tomografia computadorizada de feixes cônicos. Foram avaliados e tratados 22 pacientes com algum sinal ou sintoma de DTM articular, triados nas Clínicas do Curso de Odontologia da Universidade Estadual de Montes Claros, que preencheram os critérios de inclusão e exclusão. O diagnóstico de DTM foi realizado com o Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). Os pacientes foram submetidos a terapia com placa interoclusal estabilizadora durante 90 dias. Foram realizados três exames de tomografia computadorizada de feixes cônicos na região das ATM direita e esquerda, sendo: a primeira no início do tratamento, com o paciente na posição de MIH (G1); a segunda após 90 dias de tratamento, com o paciente ocluindo na placa interoclusal estabilizadora (G2); e a terceira após 90 dias de tratamento, com o paciente na posição de MIH (G3). Foram realizadas medidas dos espaços articulares anterior, superior e posterior em cortes sagitais das ATM. Os dados coletados foram analisados estatisticamente por meio do teste t: amostras pareadas ao nível de 5% de significância para a comparação entre dois grupos. Na comparação entre G1 e G2, e entre G3 e G2, houve aumento estatisticamente significante para o espaço articular superior e para o posterior, e não significante para o espaço articular anterior. Para a comparação entre G1 e G3 foi possível verificar aumento estatisticamente significante no espaço articular anterior e no superior, e não significante no espaço articular posterior. Os resultados da análise do RDC/TMD mostraram uma significante melhora na dor relatada pelos pacientes e aumento estatisticamente significante na abertura bucal máxima ao final da terapia com placa interoclusal estabilizadora. Considerando o método utilizado e os dados amostrais, foi possível verificar aumento espacial entre o côndilo e a cavidade articular durante o uso de placa interoclusal estabilizadora e, também, que esta terapia melhorou a dor relatada pelos pacientes e aumentou a amplitude do movimento de abertura mandibular. / The aim of this study was to evaluate the condylar position in patients with articular TMD before and after treatment with occlusal splints by cone beam computed tomography. Were evaluated and treated 22 patients with signs or symptoms of TMD joint, screened in the Clinical School of Dentistry, Universidade Estadual de Montes Claros, who met the inclusion and exclusion criteria. The diagnosis of TMD was conducted with the Research Diagnostic Criteria for Temporomandibular Disorders (RDC / TMD). The patients were subjected to therapy for occlusal splints for 90 days. Three cone beam computed tomography scans in the region of the TMJ right and left, were being conducted: the first at the beginning of treatment, with the patient in the position of MIH (G1); the second after 90 days of treatment with the patient occluding the occlusal splint (G2); and the third after 90 days of treatment with the patient in the position of MIH (G3). Measures of joint spaces were performed in front, superior and posterior in sagittal cuts of the TMJ. The collected data were analyzed statistically using the t test: paired samples at the 5 % significance level for the comparison between two groups. In the comparison between G1 and G2 and between G2 and G3, a statistically significant increase for the superior joint space and the posterior, but there was no statistically significant difference in the front joint space. For the comparison between G1 and G3, was observed a statistically significant increase in front joint space and superior, and not significant in the posterior joint space. The results of the analysis of the RDC / TMD showed a significant improvement in pain reported by patients and statistically significant increase in maximal mouth opening at the end of therapy with occlusal splints. Considering the method used and the sample data, it was possible to increase the space between the condyle and the articular cavity during use of occlusal splints and also that this therapy improved pain reported by patients and increased range of motion of mandibular opening.
123

Desenvolvimento de uma técnica de desenho digital e impressão em 3D de placas oclusais e sua aplicabilidade no tratamento de pacientes com disfunção temporomandibular / Development of a technique of digital design and 3D printing of occlusal splints and its applicability in the treatment of patients with temporomandibular disorders

Vasques, Mayra Torres 11 December 2018 (has links)
O uso de novas tecnologias na odontologia, como a técnica CAD/CAM, promete ser uma opção relevante no que diz respeito à confecção das placas oclusais, empregadas no tratamento de disfunções temporomandibulares. O objetivo desta pesquisa foi desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e verificar seus resultados clínicos no tratamento de pacientes com disfunções temporomandibulares. Para o desenho das placas foi desenvolvida uma metodologia de desenho digital (CAD), utilizando o software Meshmixer® (Autodesk, USA), e de registro das relações maxilo-mandibulares. A partir dessa metodologia iniciou-se um estudo clínico randomizado comparativo entre as placas CAD/CAM produzidas em impressora 3D e placas produzidas convencionalmente em laboratório. O estudo foi realizado em duas etapas, 18 pacientes foram avaliados de acordo com os critérios de inclusão e exclusão. Na Etapa 1 (n=18) foram realizados testes técnicos comparativos das duas placas em relação à dor, por meio da Escala Visual Analógica; atividade muscular; ajuste interno; báscula; conforto; tempo de instalação; pontos de contato oclusal. Todos os pacientes da amostra utilizaram os dois tipos de placas. Na Etapa 2, estes pacientes foram divididos randomicamente em dois grupos para o estudo clínico randomizado (estudo cego): Grupo IMP (n=9) (placas impressas) e grupo LAB (n=9) (placas convencionais laboratoriais). Os grupos foram avaliados após 1 mês de uso, por meio dos Questionários, RDC/TMD, SF-36, escala visual de dor EVA, e pelos pontos de contato oclusais. Os dados foram avaliados estatisticamente usando os testes de Wilcoxon, de Mann-Whitney, e de Kruskal-Wallis nas análises quantitativas; os testes Qui-Quadrado e Exato de Fisher, nas variáveis categóricas. Os resultados mostraram que houve diferenças significativas (P-valor<0.05) nas avaliações para conforto, ajuste interno e tempo de confecção das placas, a favor das placas impressas. Nas demais avaliações, os grupos foram equivalentes (não- significantes). Concluiu-se que foi possível desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e que o desempenho clínico foi equivalente entre as placas convencionais e impressas, sendo que estas se mostraram superiores quanto ao conforto e quanto à adaptação da superfície interna da placa, mostrando ser este um método possível e viável economicamente. / The use of new technologies in dentistry, as the CAD/CAM technique, promises to be a relevant option concerning the manufacture of occlusal splints for temporomandibular disorders treatment. The aim of this research was to develop a technique for design and manufacture occlusal splints using the CAD/CAM method and 3D printer and verify the clinical results in the treatment of temporomandibular disorders patients. It was developed a technique for occlusal splint design a using the software Meshmixer® (Autodesk, USA) and a technique to register the jaws relationship. From this method, it was started a Randomized Clinical Trial (RCT) to compare splints made through the CAD/CAM technique and others made conventionally in a dental lab. The study was performed in two steps, 18 patients were selected based on the inclusion/exclusion criteria. In Step 1 (n=18) patients were comparatively evaluated, using both splints, in relation to pain, using the visual analog scale; internal adjustment of the splint; patients comfort; time spent to deliver the appliance and occlusal contacts pattern. In Step 2, these patients were allocated in two groups (n=9 each group) randomly to the RCT be performed (blind study): Group IMP - printed splints and Group LAB (conventional lab splints). Both groups were assessed after 1 month using the splint using RDC/TMD and SF-36 questionnaires, the visual analog scale for pain, and occlusal contacts pattern. The data were statistically evaluated using Wilcoxon, Mann-Whitney, and Kruskal-Wallis test for qualitative analyses and Qui-square and Fisher´s exact tests for categorical variables. The results showed significant statistical differences (p-value<0.05) in favor of printed occlusal splints, related to patients\' comfort, internal adjustment, and time spent to deliver the appliance. All other assessments were equivalents (not significant). It was concluded that it was possible to develop a technique to design and manufacture occlusal splints using CAD/CAM and 3D printer, and furthermore the clinical performance was equivalent comparing conventional and printed occlusal splints, being the printed splints superior to conventional splints in relation to comfort and internal adjustment, proving this is a possible and economically viable method.
124

Evaluation der marginalen Passgenauigkeit verschiedener CAD-Scansysteme in Abhängigkeit vom okklusalen Öffnungswinkel der Präparation / Evaluation of the marginal fit of various CAD-scan systems depending on the occlusal angle of the preparation

Fornefett, Daniel 22 March 2011 (has links)
No description available.
125

Effets d'un appareil d'avancement mandibulaire calibré sur le bruxisme relié au sommeil

Landry-Schönbeck, Anaïs January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
126

Avaliação da atividade elétrica e limiar de dor à pressão dos músculos masseter e temporal anterior com placas de diferentes espessuras

Ribeiro, Adriana Barbosa [UNESP] 19 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-19Bitstream added on 2014-06-13T19:58:24Z : No. of bitstreams: 1 ribeiro_aab_me_araca.pdf: 786499 bytes, checksum: 4b1b56c756fa2615cf0ffe909377f642 (MD5) / A hiperatividade muscular associada ou não a alterações oclusais pode ser um fator desencadeante das desordens temporomandibulares (DTMs). Qualquer alteração nas estruturas do aparelho estomatognático pode promover um desequilíbrio funcional da mandíbula. A algometria por pressão bem como a eletromiografia tem sido utilizadas como métodos de diagnóstico e controle da evolução terapêutica dos músculos da mastigação. Diversos tratamentos buscam diminuir os sintomas característicos das DTMs pelo restabelecimento do equilíbrio, dentre os quais vale citar a terapia oclusal por meio da placa interoclusal. Uma das dificuldades durante a confecção dos dispositivos interoclusais é determinar a sua espessura. Este critério pode influenciar a eficiência, o desempenho da função de relaxamento e o tratamento da dor muscular. O objetivo deste estudo foi avaliar o efeito da espessura da placa, da consistência do alimento e do gênero, na atividade elétrica e no limiar de dor à pressão (LDP) nos músculos masseter e temporal anterior. Para verificar o efeito de diferentes espessuras de placas interoclusais foram selecionados 20 pacientes assintomáticos que utilizaram placas com espessuras 3 e 6 mm. Foram obtidas médias a partir dos valores encontrados em cada paciente, sendo avaliados lados de trabalho e não-trabalho, por meio de registros da atividade elétrica durante a mastigação de dois tipos diferentes de látex e limiar de sensibilidade dos músculos masseter e temporal anterior. Após sua obtenção, os dados foram tabulados e submetidos à análise estatística, a um nível de 5% de significância (p<0,05). Pode-se concluir que as placas de diferentes espessuras (tratamentos) e o gênero não alteraram a atividade elétrica, porém a maior consistência do alimento proporcionou atividades elétricas mais elevadas. O limiar de dor à pressão... / The muscular hyperactivity with or without occlusal changes can is a trigger of temporomandibular disorders (TMD). Any change in the structures of the stomatognathic system can promote a functional imbalance of the jaw. The algometry pressure and electromyography has been used as methods of diagnosis and therapy control of the evolution of the muscles of mastication. Several treatments seek to reduce the symptoms characteristic of TMD by restoring the occlusal, among which worth mentioning the occlusal therapy through the plate interocclusal. One of the difficulties during the construction of the splint device is to determine its thickness. This criterion can influence the efficiency, performance of the function of relaxation and treatment of muscle pain provided by interocclusal devices. The objective of this study was to evaluate the thickness of the plate, consistency of the food and gender, in the electric activity and threshold of pain to the pressure (LDP) in the muscles to masseter and anterior temporal. patients in whom signs were established with thickness 3 and 6 mm. Medium were obtained from each side to work and working from records of electrical activity during mastication of two latex sensitivity threshold of the masseter and anterior temporal of all patients. After obtaining the data, the data were tabulated and subjected to statistical analysis, a 5% level of significance (p <0.05). It It was observed that the plates of different thicknesses (treatments) and the gender had not modified the electric activity, however the biggest consistency of the food provided higher electric activities. The threshold of pain to the pressure was modified with the use of the plates of different thicknesses only for the temporal muscle of the work side, as well as was superior for the men in all the muscles evaluated, however the mastication activity did not influence in the LDP
127

Avaliação do desempenho mastigatório, força oclusal e mobilidade mandibular em crianças com e sem necessidade de tratamento ortodôntico / Evaluation of masticatory performance, occlusal strength and mandibular mobility in children with and without orthodontic treatment needs

Nicolly Parente Ribeiro Frota 24 November 2017 (has links)
Esta pesquisa avaliou o sistema estomatognático de crianças saudáveis com ou sem necessidade de tratamento ortodôntico por meio do desempenho mastigatório, contato de forças oclusais e mobilidade mandibular. Noventa crianças foram selecionadas e distribuídas em três grupos: GSN (Grau 1, sem necessidade de tratamento ortodôntico, 8,00 ± 0,43 anos de idade, n = 26), GPN (Grau 2, pequena necessidade de tratamento, 8,89 ± 0,43 anos de idade, n = 28) e GMN (Grau 3, moderada necessidade de tratamento ortodôntico, 8,44 ± 0,22 anos de idade, n = 36). A necessidade de tratamento ortodôntico foi classificada pelo Índice de Necessidade de Tratamento Ortodôntico - Componentes de Saúde Dental (IOTN-DHC). O desempenho mastigatório foi avaliado pelo integral da envoltória do sinal eletromiográfico durante os ciclos mastigatórios do músculo masseter, temporal, orbicular da boca (segmento direito e segmento esquerdo) e supra-hioideo na mastigação habitual com alimentos macios e consistentes. Foi utilizado o sistema Trigno EMG com eletrodos sem fio para captação e análise do sinal eletromiográfico (&micro;V). O sistema T-Scan® III Occlusal Analysis foi utilizado para analisar o contato de forças oclusais (%) entre as hemiarcadas superior e inferior (lado direito e esquerdo). A amplitude (mm) de abertura normal e abertura máxima voluntária e movimentos bordejantes mandibulares (lateralidade direita, lateralidade esquerda e protrusão) foi mensurada com régua milimetrada. Os dados obtidos foram tabulados e submetidos à análise estatística (SPSS 22.0, ANOVA, teste post-hoc de Bonferroni, p &le;0,05). Verificou-se que GMN apresentou menor desempenho mastigatório e desequilíbrio de forças oclusais na maxila/mandíbula em relação GPN e GSN, sem diferença significativa, e maior amplitude de abertura da boca e movimentos excursivos mandibulares com diferença significativa na abertura normal (p=0,02). Portanto, crianças com moderada necessidade de tratamento ortodôntico apresentaram alterações funcionais no sistema estomatognático, em especial no desempenho mastigatório, força oclusal e mobilidade mandibular. / This research evaluated the stomatognathic system of healthy children with or without orthodontic treatment need through masticatory performance, occlusal strength and mandibular mobility. Ninety children were selected and distributed into three groups: GSN (Grade 1, no orthodontic treatment need, 8.00 ± 0.43 years old, n = 26), GPN (Grade 2, small orthodontic treatment need, 8.89 ± 0.43 years old, n = 28) and GMN (Grade 3, moderate orthodontic treatment need, 8.44 ± 0.22 years old, n = 36). The orthodontic treatment need was classified by the Orthodontic Treatment Need - Dental Health Components Index (IOTN-DHC). The masticatory performance was evaluated by the full linear envelope of the electromyographic signal during the masticatory cycles of masseter, temporal, mouth orbicularis (left and right segments) and suprahyoids muscles in the habitual chewing with soft and consistent foods. The Trigno EMG system was used with wireless electrodes to capture and analyze the electromyographic signal (&micro;V). The T-Scan® III Occlusal Analysis system was used to analyze occlusal forces (%) between the upper and lower dental arch (right and left sides). The normal and maximum opening width (mm) and mandibular movements (right laterality, left laterality and protrusion) were measured with a millimeter ruler. Data were tabulated and submitted to statistical analysis (SPSS 22.0, ANOVA, Bonferroni post-hoc test, p&le;0.05). It was verified that GMN presented lower masticatory performance and imbalance of the occlusal forces in maxila/ mandible to GPN and GSN, with no significant difference, and greater mouth opening amplitude and mandibular excursive movements, with significant difference, in normal opening mouth (p=0.02). Therefore, children with moderate orthodontic treatment need presented functional alterations in the stomatognathic system, especially in the masticatory performance, occlusal force and mandibular mobility.
128

Avaliação dos resultados de tratamento em pacientes com disfunção temporomandibular (DTM) atendidos no ambulatório de oclusão da Faculdade de Odontologia da PUCRS utilizando questionário RDC/DTM : um estudo longitudinal

Nunes, Rejane January 2014 (has links)
O objetivo deste trabalho foi avaliar os resultados de tratamento realizado com Placa de Michigan, em pacientes com Dor Orofacial, que buscaram atendimento no Ambulatório de Oclusão da Faculdade de Odontologia da PUCRS, utilizando o questionário RDC/DTM, e associar algumas variáveis entre os resultados encontrados. Os métodos empregados foram o questionário RDC/DTM, um método já consagrado no uso para pesquisa nesta área, e ainda a aplicação de um questionário de acompanhamento sobre a dor após três meses do início do tratamento. Os resultados obtidos foram satisfatórios. / The objective of this study was to evaluate the treatment results when the stabilization (Michigan-type) splint was used, in patients with orfacial pain, who were seeking treatment in the Occlusion clinical at the Faculty of Dentistry of PUCRS, using the RDC/TMD, and associate some variables among the results found. The methods employed were the RDC/TMD, a stablished method for research in this área, and also a pain follow-up questionnaire three months after the beginning of treatment. Satisfactory results were obtained.
129

Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splints

Rodrigo Gonçalves Soares 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
130

Aplicação do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico / Applications of Farc Protocol of TMD treatment with occlusal splint and electromuographic control

Carolina Amorim Vieira e Silva 10 January 2008 (has links)
A eletromiografia de superfície (EMG) pode ser considerada atualmente um instrumento muito útil, que permite a avaliação quantitativa da musculatura de pacientes com desordem temporomandibular (DTM). O propósito do presente estudo foi aplicar e analisar os efeitos do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico, comparando os dados da avaliação, de 15 pacientes com DTM, classificados segundo o RDC / TMD, antes e após o tratamento; os resultados da EMG obtidos antes, durante e após o uso da placa por 45 dias, pelo grupo com DTM; e comparando os resultados da EMG de uma população com DTM antes e após o tratamento com placa, com um grupo controle. O exame eletromiográfico dos músculos masseter e temporal anterior foi realizado na primeira sessão de avaliação (Etapa 1), após 1 semana (Etapa 2) e após 5 semanas (Etapa 3) de tratamento, servindo para verificar a estabilidade da placa e a evolução da atividade muscular. As ondas da EMG foram analisadas, por meio do software, e os seguintes índices de EMG foram computados: coeficiente de porcentagem de sobreposição (POC) dos músculos masseter e temporal; coeficiente de torque (TORS); índice de assimetria (ASIM), índice de atividade (ATTIV) e o total da atividade elétrica (IMP). Para os dados expressos em nível intervalar de mensuração, foi empregada estatística não-paramétrica, sendo empregado o teste de Wilcoxon para dados pareados nas análises intra-grupo (entre as etapas). Os dados em nível de razão, foram analisados por meio de estatística paramétrica, sendo empregados para as análises intra-grupo o teste t para dados pareados, para as análises entre grupos o teste t para amostras independentes. O nível de significância estabelecido foi de 5%. Após o tratamento, foi encontrada diferença estatística na capacidade de abertura da boca, assim como na remissão da dor a palpação de grande parte da musculatura avaliada e na ATM. Foi obtida diferença significante no valor de POC do masseter e de IMP, imediatamente após o primeiro ajuste da placa. Quando comparada a etapa 1, sem a placa, com a etapa 2, com a placa ajustada, foi obtida diferença significante nos valores de POC do masseter, de ASIM e de IMP. Houve diferença significante entre as etapas 1, sem placa, e a etapa 3, com placa, nos valores de POC dos músculos masseter e temporal, de ASIM, ATTIV e IMP. Durante todo o tratamento não houve diferença significativa nos índices de EMG dos exames realizados sem a placa. Houve diferença estatística entre os grupos DTM e controle no início e ao final do tratamento, sendo observada diferença significante nos valores de EMG para POC de ambos os músculos e ATTIV. A placa oclusal, embora não tenha mostrado mudanças permanentes, mostrou ser efetiva para promover equilíbrio das atividades da EMG durante seu uso, e eficiente no alívio dos sintomas. Os parâmetros de pesquisa com EMG permitiram seu uso no âmbito cientifico na identificação do desequilíbrio neuromuscular, desta forma este instrumento de avaliação permitiu analisar e avaliar de forma objetiva as diferentes etapas de um tratamento tradicional para DTM na prática odontológica e diferenciar pacientes com DTM de indivíduos assintomáticos. / Surface electromyography (EMG) can currently be considered a very useful instrument which allows a quantitative assessment of masticatory muscles in patients with temporomandibular dysfunction (TMD). The purposes of this study was to apply FARC Protocol of TMD treatment with occlusal splint and electromyographic control, correlating the clinical assessment data before and after the treatment with an occlusal splint for a group of 15 patients with TMD, classified according to the RDC / TMD; comparing the results obtained with EMG, before and after treatment with an occlusal splint; comparing the EMG results for this group suffering from TMD and an asymptomatic control group. The electromyographic examination of the masseter and the anterior temporal muscles was carried out in the first assessment session (Phase 1), after one week (Phase 2) and after five weeks (Phase 3) of treatment, aiming at verifying the stability of the splint and the evolution of the muscular activity. The EMG waves were analyzed using the software, and the following EMG indices were calculated: percentage overlapping coefficient (POC) of the masseter and anterior temporal muscles; torque coefficient (TORS); asymmetry index (ASIM); activity index (ATTIV) and the total electrical activity (IMP). For data expressed at measurement interval levels, nonparametric statistics were adopted, using the Wilcoxon test for the paired data in the intra-group analysis (among the phases). Data at ratio level were analyzed through parametric statistical means: paired data t test for intra-group analysis, independent sample t test for among-group analysis. The significance level was established at 5%. After treatment, a statistical significance was found in mouth opening, as well as in the remission in the pain at palpation of a significant portion of the assessed muscles and the TMJ. A significant difference was obtained for the masseter POC and IMP, immediately after the first splint adjustment. When comparing the first phase, without the splint, to the second phase, with the first splint adjustment, a significant difference was observed in the values for masseter POC, ASIM and IMP. There was a significant difference between phase 1, without the splint, and phase 3, with the adjusted splint, for masseter and temporal POC values, ASIM, ATTIV, and IMP. Throughout the entire treatment, there were no significant differences concerning the EMG index in the examinations performed without the splint. There was a statistical significance between the TMD and the control groups in the beginning and in the end of the treatment, with significant differences observed in POC values for both muscles and ATTIV. The occlusal splint, without provoking permanent changes, proved effective to promote the balance of electromyographic activities during its use, and efficient in relieving the symptoms. The EMG parameters allow its scientific use in identifying neuromuscular unbalance, and as such, this assessment tool allowed an objective analysis and evaluation of the different phases of the traditional treatment for TMD in dentistry, differentiating patients with TMD and asymptomatic individuals.

Page generated in 0.0476 seconds