• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 287
  • 265
  • 38
  • 10
  • 9
  • 7
  • 6
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 673
  • 255
  • 143
  • 127
  • 125
  • 118
  • 117
  • 95
  • 84
  • 79
  • 61
  • 58
  • 58
  • 56
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

"Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio" / Relation of forces and deflections during loading and unloading orthodontic nickel-titanium wires

Ghersel, Herbert 18 November 2005 (has links)
O objetivo da presente pesquisa foi avaliar o comportamento da força em função da deflexão na ativação e desativação de fios ortodônticos de níquel-titânio, de secção circular (.016"). Ensaiaram-se três marcas de fio (Forestadent, GAC e Morelli). As temperaturas de ensaio foram três (32, 37 e 42ºC). As ativações máximas foram até 1, 2, 3 e 4mm. O espécime de ensaio consistiu de uma placa de resina acrílica, sobre a qual eram fixados cilindros metálicos por meio de parafusos, simulando dentes, com distribuição semelhante aos dentes naturais. Sobre os cilindros foram cimentados os bráquetes (distância de 8mm entre eles). Sobre os bráquetes era fixado, conforme clinicamente, o arco do fio em ensaio. O “dente" correspondente ao incisivo central era liberado (desparafusado) para poder se deslocar livremente no sentido vestíbulo-lingual durante os ensaios e o fio poder sofrer a deflexão. O conjunto era levado à máquina de ensaio (Instron), com câmara de temperatura controlada. Durante o ensaio a velocidade de deslocamento para a deflexão foi de 0,5mm/min. Durante a ativação e desativação as forças foram registradas de 0,10 em 0,10mm de deflexão. Por meio de software esses valores eram impressos numericamente e em gráficos da força em função da ativação/desativação. Com 4 ativações máximas, 3 marcas de fios e 3 temperaturas obtiveram-se 36 condições experimentais e com 5 repetições (n=5) foram feitos 180 ensaios. Os gráficos obtidos mostraram uma não linearidade entre força e deflexão e com ativação de 1 e 2mm não foi detectado platô de superelasticidade, mas que foi observado na desativação, das ativações máximas de 3 e 4mm. Dos gráficos e tabelas foram extraídos valores específicos para serem analisados e comparados: 1) força máxima de ativação; 2/3) diminuição da força na desativação de 0,20mm e 0,70mm (esta só na ativação de 3 e 4mm); 4/5) extensão e forças no platô (apenas nas ativações máximas de 3 e 4mm); 6/7/8) desativação até alcançar 50g de força, a partir de 0,80 e 1,80mm (ativações de 1 e 2mm), ou no final dos platôs (ativações de 3 e 4mm), a força ao iniciar-se a desativação, afastamento da origem ao registrar 50g de força; 9) deformação permanente ao atingir a força zero. As principais conclusões foram: a força de ativação máxima aumentou com o aumento desta e da temperatura, o material Morelli apresentou a menor e o GAC a maior; a diminuição da força máxima foi tanto maior quanto maior a ativação; apenas as ativações até 3 e 4mm apresentaram platôs de superelasticidade e que foram bem mais extensos na ativação de 4mm, que por sua vez apresentaram menor força; em todos os ensaios for observada deformação permanente / The purpose of this study was to evaluate the behaviour of force as function of loading and unloading orthodontic nickel-titanium wires. Three defferent brands (Forestadent, GAC and Morelli) were tested. Testing temperature were 32, 37 and 42 o C. Loading were up to 1, 2, 3 and 4mm deflection. Specimens consisted of a acrylic base where were fixed metallic cylinders simulating teeth. Over the teeth were fixed brackets to maintain arch wire in position. Tooth corresponding to central incisor was loosened and at the correspondig bráquete was applied the force in an Instron equipment, with temperature control. Head speed was 0.5mm/min. During loading and unloading forces were read every 0.10mm deflection and registered. The pair values of forces and deflections were also plotted as graphs. With 4mm maximum loading, 3 brands and 3 temperatures were obtained 36 experimental conditions and with 5 repetitions (n=5) were performed 180 tests. Graphs showed that there is no linearity between forces and deflection and with loading up to 1 and 2mm was not obtained the formation of superelasticity plateaus. But they were observed with 3 and 4mm deflections. From the graphs and registered numerical values for each specimen were selected special values to be analysed: 1) maximum loading force; 2/3) force decrease during unloading 0.20 and 0.70mm (the last only at 3 and 4mm activation); 4/5) exte nsions and forces at plateaus (only for 3 and 4mm activations); 6/7/8) extension until 50g force, since 0.80 and 1.80mm (respectively activation up to 1 and 2mm), or ends of plateau (3 and 4mm activation). In these conditions, the force at beginning unloading. Distance of origin at register 50g force; 9) permanent deformation at zero force. The main conclusions were: maximum loading forces increase with deflection and temperature increases, and brand Morelli presented the smallest force and GAC the greatest; the decrease of forces with unloading was as larger as activation force; only the activation until 3 and 4mm presented superelasticity plateaus, and was longer with 4mm activation, but it presented lower force at plateaus; in all tests was noted permanent deformation
372

Avaliação microbiana de ligaduras elastoméricas estéticas por meio da técnica checkerboard DNA-DNA hybridization: estudo in vivo / Microbial evalution of esthetic elastomeric ligatures through the Checkerboard DNA-DNA Hybridization technique: in vivo study

Raquel Fernanda Bachiega Morelli 06 December 2016 (has links)
O método de fixação do arco ortodôntico aos bráquetes cerâmicos é principalmente realizado por meio de ligaduras elastoméricas estéticas e têm sido alvo de atenção, pois, apesar da praticidade, acumulam grande quantidade de biofilme que causa degradação de cor, comprometendo permanentemente a estética. O objetivo desta pesquisa foi avaliar, in vivo, a contaminação microbiana da saliva e de 4 diferentes marcas comerciais de ligaduras estéticas: 1- Unistick Pearl American Orthodontics, Sheboygan, WI, USA; 2- Power Sticks Pearl Ortho Technology, Tampa, Flórida, EUA; 3- Ease to tie, Obscure - 3M Unitek, Monrovia, CA, USA; 4 - Ligadura modular marfimMorelli Ortodontia-Brasil, por meio da técnica Checkerboard DNA-DNA Hybridization. Foram selecionados 23 pacientes (entre 11 e 25 anos) de ambos os sexos, em tratamento ortodôntico corretivo. Foi coletado 1 ml de saliva não estimulada no momento da inserção e trinta dias após a colocação das ligaduras estéticas. Decorridos 30 dias da colocação, as ligaduras elastoméricas foram removidas, processadas individualmente e estocadas a -20°C, até o momento da análise microbiológica. Os dados foram analisados utilizando o software SAS software for Windows versão 9.1.3. Na saliva, não foram encontradas alterações estatisticamente significantes, exceto para o grupo de bactérias do complexo laranja (p=0,0493). Os resultados encontrados nas ligaduras elastoméricas estéticas mostraram acúmulo significativo nas bactérias do complexo laranja (p=0,0167), enquanto que nos outros complexos e nas bactérias cariogênicas não observamos diferenças estatisticamente relevantes. Evidenciou-se que a ligadura estética da marca comercial Morelli, apresentou menores níveis de contaminação bacteriana (p=0,0108) nos meninos. Assim, conclui-se que as ligaduras elastoméricas estéticas, no período de 30 dias, foram multicolonizadas por várias espécies de micro-organismos, especialmente as do complexo laranja, reforçando a necessidade de uma higiene bucal rigorosa em pacientes ortodônticos. / The attachment for orthodontic archwires to ceramic brackets are mainly done by means of aesthetic elastomeric ligatures, therefore, they have been subject of attention because they accumulate a great amount of biofilm, causing color degradation then compromising their aesthetic visual. The objective of this research was to analyze, in vivo, the microbial contamination of saliva and 4 different brands of aesthetic ligatures: 1- Unistick Pearl - American Orthodontics, Sheboygan, WI, USA; 2- Power Sticks -Pearl Ortho Technology, Tampa, Florida, EUA; 3- Ease to tie, Obscure - 3M Unitek, Monrovia, CA, USA; 4 - Ligadura modular marfimMorelli Ortodontia-Brasil, through the Checkerboard DNA-DNA Hybridization technique. Twenty-three patients (between 11 and 25 years old) of both genders, under orthodontic treatment were selected. One milliliter of non-stimulated saliva, at time of inserting the ligatures and 30 days after its insertion, was collected. Thirty days after the placement the elastomeric ligatures were removed, individually processed and stored at -20°C, until the microbiological analysis. The data were analyzed using the SAS software for Windows version 9.1.3. No statistically significant changes were found in the saliva values, except for the bacterias of the orange complex (p = 0.0493). The obtained results in the aesthetic elastomeric ligatures showed a significant increase in the orange bacterial complex (p=0,0057), while in the others complexes no statistically differences were observed. The Morelli commercial brand of aesthetic ligature showed lower bacterial contamination levels (p=0,0108) in boys. Thus, it can be concluded that the aesthetic elastomeric ligatures, in a 30-day period, were multi-colonized by various species of microorganisms, especially from the orange complexes, reinforcing the need for a thorough oral health care in orthodontic patients.
373

Avaliação da resistência ao Cisalhamento de braquetes novos recolocados com diferentes resinas ortodônticas / Evaluation of shear bond strength of new metallic brackets rebounded with different orthodontic resins

Jimenez, Emigdio Enrique Orellana 04 December 2007 (has links)
Made available in DSpace on 2017-07-24T19:22:06Z (GMT). No. of bitstreams: 1 Emigdio Enrique Orellana Jimenez.pdf: 1399808 bytes, checksum: 9a5dfb23c60c52032fb9609d09fd87ca (MD5) Previous issue date: 2007-12-04 / The present study evaluated in vitro the shear bond strength of new bonded and rebounded metallic brackets with three orthodontic composites. Ninety extracted first superior premolars were randomly divided in three groups, according to the different tested composite. All bonding procedures followed the manufacturer’s specifications with a 300g standard pressure over the bracket during positioning. Alpha plast (AP), Concise (CO) and Transbond XT (TB) were the evaluated composites. For each group, three shear bond strength examinations were performed in three different times, initial (T0), first rebonding (T1) and second rebonding (T2), with a 24 hour interval between them. The tests were performed with a SHIMADZU AG-I, (10KN) machine with a 0,5 mm/min cross-head speed and the fracture strength was recorded in Megapscal (MPa) considering brackets base area. The mean shear bond strength was evaluated and the adhesive remnant index (ARI) was scored. The results showed that in T0 the groups AP and CO presented similar and higher values than TB, in T1 and T2 the highest shear bond strength values were found in group AP, followed by group CO and TB. Those data were submitted to two-way ANOVA and Tukey´s and Bonferroni´s test (p<0,05) and the ARI results were analyzed by the Kruskal Wallis test followed by the Dunn´s test. It was found a statistical significant difference (p<0,05) in shear bond strength between groups but not between the different bonding and rebonding times. The highest shear bond strength values were observed in the group AP, followed by CO and TB. In relation to ARI, it was noticed a significant statistical difference (p<0,05) between the groups, and the TB presented higher values (p<0,05) than those verified in AP and CO, for T0 and T2. It was concluded that repeated bondings with new brackets presented an adhesive difference in shear bond strength considering the utilized composite, however, at bonding and rebonding with the same composite, there are no significant differences. / Este estudo avaliou in vitro a resistência ao cisalhamento de braquetes metálicos novos colados e recolados com três resinas ortodônticas. Foram utilizados 90 primeiros pré-molares superiores humanos extraídos para a confecção dos corpos de prova, os quais foram divididos aleatoriamente em três grupos;(n = 30) de acordo com a resina utilizada. Todos os procedimentos de colagem seguiram as recomendações do fabricante com uma pressão padronizada em 300g. Foram utilizadas as resinas Alpha Plast (AP), Concise (CO) e Transbond XT (TB). Para cada um dos grupos foram realizados três ensaios de cisalhamento em três tempos, um inicial (T0) e os outros dois T1 e T2, primeira e segunda recolagens, respectivamente, com intervalos de 24 horas. Os testes de cisalhamento foram realizados em uma máquina eletrônica de ensaios eletromecânicos SHIMADZU AG-I, (10KN), com velocidade de pressão de 0,5mm/min e carga de ruptura registrada em Megapascal (MPa). Considerando a área da base do braquete, foram mensuradas as resistências médias ao cisalhamento e o índice de adesivo remanescente (IAR). Os resultados demonstraram que para T0 os grupos AP e CO apresentaram valores próximos e superiores a TB, para T1 e T2 os maiores valores de resistência foram observados para o grupo AP, seguido dos grupos CO e TB. Estes dados foram submetidos à ANOVA 2 critérios e ao teste de Tukey e de Bonferroni (p<0,05) e para o IAR o teste Kruskal Wallis, seguido de teste Dunn. Existe diferença estatística significante (p<0,05) na resistência ao cisalhamento (MPa) entre os grupos mas não entre os tempos de colagem e recolagem de braquetes novos, sendo que os maiores valores de resistência ao cisalhamento foram encontrados no grupo AP, seguido de CO e TB. Em relação ao IAR, existiu diferença estatisticamente significante (p<0,05) entre os grupos, o grupo TB foi estatisticamente superior (p<0,05) aos grupos AP e CO, para o T0 e T2. Concluiu-se que colagens repetidas com braquetes novos apresentam diferença adesiva de resistência ao cisalhamento considerando a resina utilizada, porém na colagem e recolagens com a mesma resina não há diferenças significativas.
374

Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadas

Rastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5) Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets bonded with fluoride-releasing composite resins, and to compare them to a conventional resin. For this study, sixty premolars extracted due to orthodontic reasons were used, which were divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at 37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the specimens were submitted to the shear bond strength test, in occluso-gingival direction, in Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis, Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20 MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the averages of the three groups were significantly different among themselves (p<0.05), with the highest resistance for the Concise Group and the lowest for the Ultrabond Group. However, all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M), Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ± 6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de 16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001). O teste de Tukey evidenciou que as médias dos três grupos foram significativamente diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva adequada para uso clínico.
375

AVALIAÇÃO CLÍNICA DO USO PRÉ-OPERATÓRIO DA DEXAMETASONA E IBUPROFENO PARA CONTROLE DA DOR NO TRATAMENTO ORTODÔNTICO / Germiniani, WIS. Clinical evaluation of the preemptive use of dexamethasone and ibuprofen for pain control in orthodontic treatment

Germiniani, Wagner Izumi Sawada 15 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:18Z (GMT). No. of bitstreams: 1 WagnerIzumi Germiniani.pdf: 407803 bytes, checksum: 3185ccd19b894a129c2afe657f200679 (MD5) Previous issue date: 2012-02-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The pain may be the main reason of interruption ordiscontinuance of orthodontic treatment. Most patients experience at some stage of the treatment any kind of pain anddiscomfort. The aim of this randomized double-blind parallel placebo- ontrolled clinical trial was to compare the clinical actionof the preemptive use of dexamethasone and ibuprofen for reliefor pain control during orthodontic treatment. It was selected one hundred patients in orthodontic treatment in the clinic of orthodontics at State University of Ponta Grossa. The mean age was 25 years (range from 18 to 49 years). Patients were divided into three experimental groups: G1 (n = 25) received anenvelope containing 600mg of ibuprofen arginine 555mg withG2 (n = 25) one tablet of 4mg dexamethasone; G3 (n = 50) placebo control. Each participant answered a questionnaire inwhich dental anxiety reported prior experience with the treatmentof pain. The drugs were administered previously the query of placing rectangular arches, and each participant wrote downspecific form of the experience of pain at times 2,6,12,24 and 48hours after device activation. To measure the pain experience of each participant was used a numerical scale of 101 points(NRS).The results showed that except in time of 2 hours, G1 and G3 showed no statistically significant differences . The G2 group showed the lowest pain scores at all times and showed statistically significant differences compared to G1 and G3. It may be concluded that ibuprofen is effective for pain relief only in a period of up to 2 hours after orthodontic activation and that dexamethasone may be indicated as a medication of choice because it is efficient in the period up to 48 hours. / A dor pode ser o principal motivo de interrupção ou desistência do tratamento ortodôntico. A maioria dos pacientes experimenta em alguma etapa do tratamento algum tipo de dor e/ou desconforto. O objetivo deste estudo clínico randomizado duplo cego paralelo controlado por placebo foi comparar a ação clínica do uso pré-operatório de dexametasona e do ibuprofeno para alívio e/ou controle da dor durante o tratamento ortodôntico. Foram selecionados 100 pacientes em tratamento ortodôntico na clínica de Ortodontia da Universidade Estadual de Ponta Grossa com idade média de 25 anos (de 18 a 49 anos). Os pacientes foram divididos em 3 grupos experimentais: G1(n=25) recebeu um envelope contendo 600mg de ibuprofeno com 555mg de arginina; G2 (n=25) um comprimido com 4mg de dexametasona; G3 (n=50) controle por placebo.Cada participante respondia um questionário de ansiedade dentária onde relatava sua experiência prévia de dor com o tratamento. Os medicamentos eram administrados previamente a consulta de colocação de arcos retangulares e cada participante anotava em ficha específica a experiência de dor nos tempos 2, 6,12,24 e 48 horas após a ativação do aparelho. Para mensurar a experiência de dor de cada participante foi utilizada uma numérica de 101 pontos (NRS). Os resultados apontaram que exceto no tempo de 2 horas, os grupos G1 e G3 não apresentaram diferenças estatisticamente significantes. O grupo G2 revelou os menores escores de dor em todos os tempos e apresentou diferenças estatisticamente significantes em relação a G1 e G3. Pode-se concluir que o ibuprofeno é eficiente para alívio da dor apenas num período até 2 horas após a ativação ortodôntica e que a dexametasona pode ser indicada como medicamento de escolha pois se mostrou eficiente no período de até 48 horas.
376

Bráquetes convencionais e autoligados: detecção de micro-organismos na saliva e in situ, avaliação de parâmetros periodontais e quantificação de citocinas no fluido crevicular / Self-ligating and Conventional brackets: Microbial detection in the saliva and in situ, periodontal index evaluation and assessment of cytokines levels in the gingival crevicular fluid

Ana Zilda Nazar Bergamo 25 July 2014 (has links)
O aparelho ortodôntico promove alterações microbiológicas na cavidade bucal, em função da variedade de materiais sólidos e elásticos que possuem, os quais funcionam como áreas de retenção, levando a um acúmulo de biofilme e predispondo o hospedeiro à cárie dental e à doença periodontal. Os objetivos do presente estudo, in vivo, foram: 1) Avaliar, as alterações no índice de placa (PI), índice gengival (GI), índice de sangramento gengival (GBI) e no volume do fluido crevicular, em pacientes com 3 diferentes desenhos de bráquetes metálicos (autoligados e convencionais), a fim de verificar se o desenho dos bráquetes interfere no acúmulo de placa e na saúde gengival; 2) Estudar as alterações nos níveis de diferentes micro-organismos envolvidos direta ou indiretamente na cárie dental, na saliva e in situ, pré e pós-colagem de bráquetes convencionais e autoligados; 3) Avaliar os níveis salivares e in situ, de espécies de micro-organismos dos complexos roxo, verde, laranja e vermelho e de outras espécies, pré e pós-colagem de bráquetes convencionais e autoligados, por meio de sondas de DNA e 4) Quantificar citocinas pró-inflamatórias no fluido crevicular, antes e após a colagem dos diferentes bráquetes. A amostra foi constituída de 20 pacientes, com idade entre 11 e 15 anos (Média: 13,3 anos), que receberam bráquetes metálicos convencionais GeminiTM e dois diferentes tipos de bráquetes autoligados: In-Ovation®R e SmartClipTM em incisivos e caninos superiores. Os índices, o volume do fluido e as amostra de saliva (S0) foram obtidos antes da instalação dos aparelhos (T0) e após 30(T1) e 60(T2) dias. Um bráquete de cada tipo foi removido 30 e 60 dias após a colagem. Os dados foram submetidos à análise estatística utilizando-se os testes não-paramétricos de Friedman, Mann-Whitney e Wilcoxon e coeficiente de correlação não-paramétrico de Spearman. A análise da concentração de citocinas no fluido crevicular foi realizada segundo modelo de análise de variância misto, seguida pelo teste de Tukey, com nível de significância de 5%. Não houve correlação entre o grau de apinhamento, overjet e overbite com os escores do índice de placa (PI), índice gengival, índice de sangramento gengival e com o volume do fluido crevicular no tempo inicial T0 (p>0,05). Verificou-se a diferença significativa nos escores de PI e volume do fluido crevicular somente nos dentes que receberam bráquetes autoligados SmartClipTM, entre os tempos T0-T2(p<0,05). Identificou-se a presença de 21 das 22 espécies bacterianas e 4 das 5 espécies fúngicas, na saliva, antes da colagem dos aparelhos ortodônticos. In situ, no bráquete autoligado SmartClipTM observou-se maiores níveis de espécies do complexo vermelho 60 dias após a colagem. Para os bráquetes convencionais GeminiTM verificou-se diminuição nos níveis de espécies do complexo roxo. Para o bráquete autoligado In-Ovation®R identificou-se diferença significativa para C. rectus 30 dias após a colagem e para S. mutans 60 dias após a colagem. Quando comparou-se os níveis salivares e os in situ, verificou-se maiores níveis de espécies nos bráquetes, in situ, sendo que os autoligados apresentaram os maiores valores. Aumento significante foi verificado para os bráquetes autoligados In-Ovation®R, para S. mutans e L. casei. Após 60 dias da colagem do aparelho ortodôntico observou-se um aumento nos níveis de TNF-&alpha; (p<0.005), em todos os tipos de bráquetes. Considerando-se as condições específicas desse estudo, pode-se concluir que o desenho do bráquete modulou o índice de placa, o volume do fluido crevicular, e os níveis bacterianos do complexo vermelho, sendo o bráquete autoligado SmartClipTM o que apresentou o pior desempenho, nesse aspecto. O bráquete autoligado In-Ovation®R apresentou maiores níveis bacterianos relacionados à cárie dental e espécies do complexo laranja. A concentração de citocinas no fluido crevicular não foi modulada pelo desenho do bráquete, ocorrendo um aumento na concentração de TNF-&alpha; nos três tipos de bráquetes (convencional e autoligados) 60 dias após a colagem. A análise global dos resultados obtidos nos diferentes parâmetros analisados no presente estudo permitiu evidenciar, em geral, melhores resultados clínicos com o bráquete metálico convencional GeminiTM. / The orthodontic appliance promoting several changes in oral cavity according to the variety of solid and elastic materials used in the treatment, leading to the biofilm development. The aim of this study, in vivo, was: 1) Evaluate the periodontal index: Plaque Index (PI), Gingival Index (GI), Gingival Bleeding Index (GBI)and gingival crevicular fluid volume. 2) The levels of cariogenic and periodontopatogenical bacteria in saliva and in two different metallic brackets: self-ligating and conventional, quantify the levels before and 30 and 60 days after bonding orthodontic appliance. 3) The levels of red, orange green and purple complex and others species, in situ and in the saliva. 4) The pro-inflammatory cytokines levels in the gingival crevicular fluid. The sample consisted of 20 patients, aged between 11 and 15 years (mean 13.3 years) who received conventional metal bracket GeminiTM and two different types of self-ligating brackets: In-Ovation®R and SmartClipTM in maxillary incisors and canines. The rates, the volume of the fluid and saliva sample (S0) were obtained before the device (T0), 30 (T1) and 60 (T2) after bonding. A type of each bracket was removed 30 to 60 days after bonding. Data were analyzed statistically using the nonparametric Friedman test, Mann-Whitney and Wilcoxon coefficient and nonparametric Spearman correlation with a significance level of 5 %. The cytokine levels was analyzed by the mixed models, follow to the Tukey test. There was no correlation among the scores of crowding, overjet and overbite with the scores of plaque index (PI), gingival index (GI), gingival bleeding index (GBI) and volume of crevicular fluid at the initial time T0 (p>0.05). There was a significantly difference in PI and crevicular fluid volume, when compared each bracket separately, only the teeth that received self-ligating bracket SmartClipTM, between times T0-T2 (p<0.05). We identified, in the saliva, the presence of 21, bacterial species, of the 22 analyzed; 4 of the 5 fungal species, before bonding the orthodontic appliance. In situ, to the SmartClipTM the highest levels were observed to the red complex 60 days after bonding. To the GeminiTM a decreased to the purple complex was observed when compared 30 and 60 days after bonding. The In-Ovation®R showed a significantly difference to C. rectus, 30 days after bonding. S. mutans, 60 days after bonding. 30 days after bonding the microbial levels is highest in the saliva than in situ, the self-ligating brackets present the highest levels than conventional brackets. 60 days after bonding the TNF-&alpha; levels was increased (p<0,05). The microbial levels was highest in the self-ligating brackets than the conventional brackets. The bracket design seems influenced the plaque index, the volume of the crevicular fluid, the microbial adhesion. The levels in situ are highest than in saliva. The TNF-&alpha; levels were increased 60 days after bonding. The bracket design change the PI, gingival crevicular volume and the red complex species, the SmartClipTM showed the worst results in this point. The In-Ovation®R presented the highest levels of the species to the orange complex and cariogenic species. The design didn\'t modulated the cytokine levels, th TNF&alpha;, increased for all brackets. The global analyses of the results allows us to conclude that the GeminiTM conventional bracket showed the best results when compared to the others self-ligating.
377

Efeitos citotóxicos e genotóxicos em pacientes com aparelho ortodôntico corretivo avaliados por frequência de micronúcleos / Cytotoxic and genotoxic effects in patients with orthodontic appliances evaluated for frequency of micronuclei

María Gabriela Flores Bracho 27 October 2015 (has links)
A corrosão dos aparelhos ortodônticos pode induzir uma resposta inflamatória e causar alterações nos tecidos bucais de pacientes em tratamento. Portanto, o objetivo deste estudo foi avaliar os efeitos citogenéticos causados em células epiteliais bucais de pacientes submetidos a tratamento ortodôntico corretivo e compará-los a um grupo controle sem tratamento. Setenta e quatro (74) pacientes em tratamento ortodôntico corretivo e vinte e um (21) pacientes controle com idades entre 11 e 35 anos participaram da pesquisa, de ambos os gêneros e que estavam em atendimento na clínica de pós-graduação em Ortodontia da Faculdade de Odontologia, Ribeirão Preto-USP. Os pacientes em tratamento foram divididos em quatro grupos que se diferenciaram pelo tempo de tratamento G1, n= 21 (1 mês a 12 meses de tratamento), G2, n= 21 (13 a 24 meses), G3, n= 23 (25 a 48 meses de tratamento) e G4, n=9 (acima de 48 meses de tratamento). As células foram coletadas por raspagem leve da parte interna da bochecha, com escova de dente e posteriormente colocadas em tubos de polietileno contendo soro fisiológico. Imediatamente após a obtenção da amostra foi realizada a avaliação dos danos citogenéticos por meio do teste de micronúcleos (MNT). Análises bivariadas foram realizadas nos dados obtidos utilizando testes paramétricos (Teste t, ANOVA) e testes não paramétricos quando necessário (teste do qui-quadrado ou exato e teste Kruskall Wallis seguido do teste de pós-teste de Dunn). Não foram encontradas diferenças estatisticamente significantes para nenhuma das anomalias citogenéticas, exceto para a \"cariolíticas\" que foi maior no grupo controle. Concluiu-se que não foram encontrados danos estatisticamente significantes, sendo o tratamento ortodôntico seguro em pacientes saudáveis com capacidade de reparo normal. / The corrosion of orthodontic appliances can induce an inflammatory response and cause changes in bucal tissues from patients undergoing treatment. Therefore, the aim of this study was to evaluate the cytogenetic damage in bucal epithelial cells of patients undergoing corrective orthodontic treatment and compare them to a control group without orthodontic treatment. Seventy-four (74) patients in orthodontic treatment and twenty-one (21) control individuals aged between 11 and 35 years participated in the research, of both genders and who were in attending at the clinic graduate in Orthodontics at Faculty of Dentistry, Ribeirão Preto-USP. The patients were divided into four treatment groups by treatment time; G1, n= 21 (1 month to 12 months of treatment), G2, n = 21 (13 to 24 months), G3, n = 23 (25 to 48 months of treatment) and G4, n = 9 (over 48 months of treatment). The cells were collected by gentle scraping with a toothbrush of the inside of the cheek and later placed in polyethylene tubes containing Physiological saline. Immediately after, the samples were evaluated for cytogenetic damage through the micronucleus test (MNT). Bivariate analyzes were performed using parametric tests (t test, ANOVA) and nonparametric tests when necessary (chi-square test or Kruskal Wallis test accurate and followed by Dunn test posttest). Thus, there wasn`t significant differences for any of the cytogenetic abnormalities except for karyolysis which was higher in the control group. It was concluded that statistically significant damage were not found, and orthodontic treatment is safe in healthy patients with repair capacity.
378

Resistência ao cisalhamento de bráquetes ortodônticos cerâmicos colados com diferentes compósitos e irradiados com laser de CO2 / Shear strength of ceramic orthodontic brackets bonded with different composites and irradiated with CO2 laser

Denise de Souza Matos 25 April 2013 (has links)
O objetivo do trabalho foi avaliar a resistência ao cisalhamento de bráquetes ortodônticos cerâmicos com base de retenção química e mecânica, colados com diferentes compósitos e irradiados com laser de CO2. Foram utilizados 120 pré-molares humanos hígidos, suas coroas foram incluídas em resina acrílica e as faces vestibulares planificadas e polidas com lixas d\'água até exposição de 5mm esmalte. Posteriormente, as raízes dos dentes foram incluídas em tubos de PVC também com resina acrílica de forma que a face vestibular ficasse perpendicular à base do tubo. Os 120 corpos de prova foram divididos em 8 grupos (n=15), sendo 2 controles e 6 experimentais. Nos grupos 1 e 2 (controles) o compósito utilizado para colagem foi o Transbond XT, sendo que no grupo 1 foi colado o bráquete cerâmico Mystique (retenção mecânica) e no grupo 2 o bráquete cerâmico Fascination (retenção química). Nos grupos experimentais 3, 4 e 5 foi colado o bráquete Mystique com os compósitos Transbond XT, Concise e Z250, respectivamente. Nos grupos 6, 7 e 8 foi colado o bráquete Fascination com os mesmos compósitos dos grupos 3, 4 e 5, na mesma sequência. Nos grupos experimentais, após a colagem, os bráquetes foram irradiados com laser de CO2 com 10W de potência por 3 segundos e pulso de 0,01 segundo. Imediatamente após a irradiação foi realizado o teste de resistência ao cisalhamento da colagem em máquina universal de ensaios mecânicos (Emic DL 500) à velocidade de 0,5 mm/minuto. Após o teste, as superfícies avaliadas por meio do Índice de Remanescente Adesivo (IRA) e submetidas à Microscopia Eletrônica de Varredura (MEV) para investigação de eventuais fraturas. Os dados de resistência ao cisalhamento foram submetidos à Análise de Variância ANOVA e posteriormente teste de Tukey. O teste de Mann-Whitney foi utilizado para a avaliação do IRA. Os resultados mostraram que os grupos experimentais apresentaram valores de resistência ao cisalhamento menores quando comparados aos controle (p 0,05). O bráquete Mystique (retenção mecânica) apresentou valores maiores de resistência ao cisalhamento e o compósito Z 250 foi o que apresentou menor força de adesão após irradiação com laser de CO2. Os grupos 5 e 8 foram os que apresentaram maior média do IRA e para todas as superfícies avaliadas o modo de fratura mais prevalente foi a fratura adesiva . Concluiu-se que o laser de CO2 foi eficaz como auxiliar na descolagem de bráquetes cerâmicos de retenção química e mecânica. / The objective of this study was to evaluate the shear strength of the ceramic orthodontic brackets based in chemical and mechanical restraint, bonded with different composites and irradiated with CO2 laser was evaluated. Healthy human premolars (120) were used and their crowns were embedded in acrylic resin and the buccal surfaces flattened and polished with sandpaper until exposure of 5 mm of enamel. Subsequently, the roots of the teeth were included in PVC pipes also with acrylic resin so that the labial surface was perpendicular to the base of the pipe. The 120 samples were divided into 8 groups (n = 15), 2 being the control groups and 6, the experimental groups. In groups 1 and 2 (controls) the composite used for bonding was Transbond XT. Group 1 was glued to the ceramic bracket Mystique (by mechanical retention) and the group 2, with ceramic bracket Fascination (by chemical restraint). In the experimental groups 3, 4 and 5 Mystique brackets were glued with Transbond XT, Concise and Z250, respectively. In groups 6, 7 and 8 the Fascination bracket were glued with the same composites of groups 3, 4 and 5 and in the same sequence. In the experimental groups, after bonding, the brackets were irradiated with CO2 laser with 10W of power for 3 seconds and per pulse 0.01 seconds. Immediately after irradiation shear strength tests were performed on shear bonding with mechanical universal testing machines (Emic DL 500) at a speed of 0.5 mm/minute. After testing, the surfaces were evaluated using the Adhesive Remnant Index (ARI) and submitted to scanning electron microscopy (SEM) to investigate possible fractures. The shear strength data were subjected to analysis of variance with ANOVA and Tukey test later. The Mann-Whitney test was used to evaluate the ARI. The results showed that experimental groups showed lower shear strength values, comparing to the control groups (p 0.05). The bracket Mystique (mechanical retention) showed higher shear strength values and the Z 250 composite showed the lowest adhesion strength after irradiation with CO2 laser. Groups 5 and 8 presented the highest average of IRA and for all the surfaces that were evaluated the most prevalent fracture mode was the adhesive one. It was concluded that the CO2 laser was effective as an aid in bracket debonding of ceramic with chemical and mechanical retention.
379

Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo alveolar por meio da tomografia computadorizada de feixe cônico / Changes in arch dimensions, buccolingual inclinations and alveolar bony support during alignment using Damon MX: a CBCT study

Morais, Juliana Fernandes de 28 November 2012 (has links)
Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo por meio da tomografia computadorizada de feixe cônico Este estudo objetivou analisar as alterações nas inclinações vestibulolinguais dos dentes, nas dimensões dos arcos e nas espessuras das tábuas ósseas vestibulares durante o alinhamento com Sistema Damon, como também identificar fatores pré-tratamento (espessura óssea inicial, larguras dos arcos, apinhamento) e alterações do tratamento (expansão dos arcos, vestibularização dos dentes) possivelmente associados. Vinte e dois adolescentes com dentadura permanente completa até primeiros molares, tratados sem extrações e apinhamento inicial mínimo de 4mm superior: -6,71mm (DP 2,99), inferior: -5,12mm (DP 2,03) foram escaneados por tomografia computadorizada de feixe cônico (TCFC) antes (T0) e após (T1) o alinhamento com o Sistema Damon. As dimensões dos arcos e as inclinações vestibulolinguais dos dentes foram avaliadas a partir das TCFC (T0 e T1) em modelos 3D e cortes multiplanares, enquanto o apinhamento foi mensurado nos modelos de estudo (T0). A spessura das tábuas ósseas vestibulares nos ¾ coronais e ¼ apical da raiz dentária foram mensuradas por meio de imagens de tomográficas parassagitais (0,3mm de espessura) das duas fases T0 e T1, nas áreas de incisivos centrais superiores e de segundos pré-molares e primeiros molares superiores e inferiores. As variáveis foram submetidas ao teste de de Shapiro-Wilk para testar sua distribuição. As alterações de todas as variáveis de T0 para T1 foram comparadas por meio dos testes t pareado ou de Wilcoxon. A correlação entre as alterações das espessuras ósseas com os possíveis fatores associados foi verificada pelo coeficiente de correlação de Pearson ou teste de correlação de Spearman. O alinhamento com o Sistema Damon produziu expansões dos arcos associados à proclinação dos dentes e à redução na espessura óssea vestibular. As tábuas ósseas vestibulares tornaram-se não mensuráveis com o alinhamento em 25% das raízes mesiovestibulares dos primeiros molares superiores. A redução nas espessuras ósseas vestibulares mensuráveis, recobrindo os ¾ coronais da raiz, foi significante nas áreas de incisivo central superior (-13,22%), raiz mesiovestibular do primeiro molar superior (-20,54%) e raízes mesial e distal do primeiro molar inferior (-15,58% e -11,38%, respectivamente). Houve tendência ao aumento da espessura óssea vestibular da raiz distovestibular do primeiro molar superior (p= 0,051), provavelmente devido à rotação do molar com o alinhamento. A redução na espessura óssea vestibular durante o alinhamento dentário mostrou correlação positiva com a espessura óssea e apinhamento iniciais no arco superior, bem como com a distância inter-segundos-prémolares pré-tratamento no arco inferior. Os arcos mais expandidos durante a fase de alinhamento tenderam a sofrer maior redução nas espessuras ósseas vestibulares. Conclui-se que o Sistema Damon produz expansões dos arcos associados à redução óssea vestibular durante a fase de alinhamento. Dentes com ossos mais finos e apinhamentos mais severos antes do tratamento apresentam maior risco para redução na tábua óssea vestibular e a quantidade de expansão durante o tratamento pode potencializar esse efeito. / This study aimed first to assess the changes in teeth buccolingual inclinations, arch dimensions, and buccal bony plate thicknesses occurred during the alignment phase using a self-ligating brackets system (Damon MX). Secondly, to identify pre-treatment (initial bone thickness, initial arch widths, initial crowding) or treatment parameters (amount of expansion, amount of buccal tipping) that could act as risk predictors for buccal bone reduction during orthodontic treatment. Twenty-two adolescents with complete permanent dentition until first molars, minimum initial crowding of 4mm - maxillary: -6.71 mm (SD 2.99), mandibular: - 5.12 mm (SD 2.03) - treated without extractions were scanned by cone beam computed tomography (CBCT) before (T0) and after (T1) alignment using Damon System. Arch dimensions and teeth buccolingual inclinations were evaluated by means of digital models and multiplanar reconstructed images both obtained from CBCT (T0 and T1), crowding was measured on study casts (T0). Alveolar buccal bone thickness overlying the ¾ coronal and the ¼ apical of the root were measured in the areas of maxillary central incisors, as well as maxillary and mandibular premolars and first molars by means of cross-sectional images reconstructed with 0.3 mm thickness at T0 and T1, Distribution of the variables was verified by Shapiro-Wilks test. Changes in all variables from T0 to T1 were compared using paired t test or Wilcoxon test. The correlation between changes in bone thickness with its possible associated factors was assessed by Pearson correlation coefficient or Spearman correlation test. Alignment using Damon System produced substantial arch expansion associated with proclination of teeth and reduction in buccal bone thickness. The buccal bone plates overlying 25% of the mesiobuccal roots of the maxillary first molars became unmeasurable during the alignment phase. The reduction in the measurable buccal bone thickness, overlying the ¾ coronal root length, was significant in the areas of maxillary central incisor (-13.2%), mesiobuccal root of maxillary first molar (-20.5%), mesial and distal roots of mandibular first molar (-15.6% and -11.4%, respectively). There was a tendency for increasing buccal bone thickness root overlying the distobuccal root of maxillary first molar (p = 0.051), probably due to molar rotation during the alignment phase. The reduction in buccal bone thickness during alignment with Damon System showed a positive correlation with initial bone thickness and initial crowding in the maxillary arch, and the pre-treatment inter-secondpremolar width in the mandibular arch. The more expanded the arch during the alignment phase, the greater reduction in buccal thickness bone. It is concluded that the Damon system produces arch expansion associated with decrease in buccal bone thickness during the alignment phase. Thinner buccal bony plates and more severe crowding before treatment increase the risk for buccal bone reduction and the amount of expansion during treatment may further enhance this effect.
380

Bráquetes convencionais e autoligados: detecção de micro-organismos na saliva e in situ, avaliação de parâmetros periodontais e quantificação de citocinas no fluido crevicular / Self-ligating and Conventional brackets: Microbial detection in the saliva and in situ, periodontal index evaluation and assessment of cytokines levels in the gingival crevicular fluid

Bergamo, Ana Zilda Nazar 25 July 2014 (has links)
O aparelho ortodôntico promove alterações microbiológicas na cavidade bucal, em função da variedade de materiais sólidos e elásticos que possuem, os quais funcionam como áreas de retenção, levando a um acúmulo de biofilme e predispondo o hospedeiro à cárie dental e à doença periodontal. Os objetivos do presente estudo, in vivo, foram: 1) Avaliar, as alterações no índice de placa (PI), índice gengival (GI), índice de sangramento gengival (GBI) e no volume do fluido crevicular, em pacientes com 3 diferentes desenhos de bráquetes metálicos (autoligados e convencionais), a fim de verificar se o desenho dos bráquetes interfere no acúmulo de placa e na saúde gengival; 2) Estudar as alterações nos níveis de diferentes micro-organismos envolvidos direta ou indiretamente na cárie dental, na saliva e in situ, pré e pós-colagem de bráquetes convencionais e autoligados; 3) Avaliar os níveis salivares e in situ, de espécies de micro-organismos dos complexos roxo, verde, laranja e vermelho e de outras espécies, pré e pós-colagem de bráquetes convencionais e autoligados, por meio de sondas de DNA e 4) Quantificar citocinas pró-inflamatórias no fluido crevicular, antes e após a colagem dos diferentes bráquetes. A amostra foi constituída de 20 pacientes, com idade entre 11 e 15 anos (Média: 13,3 anos), que receberam bráquetes metálicos convencionais GeminiTM e dois diferentes tipos de bráquetes autoligados: In-Ovation®R e SmartClipTM em incisivos e caninos superiores. Os índices, o volume do fluido e as amostra de saliva (S0) foram obtidos antes da instalação dos aparelhos (T0) e após 30(T1) e 60(T2) dias. Um bráquete de cada tipo foi removido 30 e 60 dias após a colagem. Os dados foram submetidos à análise estatística utilizando-se os testes não-paramétricos de Friedman, Mann-Whitney e Wilcoxon e coeficiente de correlação não-paramétrico de Spearman. A análise da concentração de citocinas no fluido crevicular foi realizada segundo modelo de análise de variância misto, seguida pelo teste de Tukey, com nível de significância de 5%. Não houve correlação entre o grau de apinhamento, overjet e overbite com os escores do índice de placa (PI), índice gengival, índice de sangramento gengival e com o volume do fluido crevicular no tempo inicial T0 (p>0,05). Verificou-se a diferença significativa nos escores de PI e volume do fluido crevicular somente nos dentes que receberam bráquetes autoligados SmartClipTM, entre os tempos T0-T2(p<0,05). Identificou-se a presença de 21 das 22 espécies bacterianas e 4 das 5 espécies fúngicas, na saliva, antes da colagem dos aparelhos ortodônticos. In situ, no bráquete autoligado SmartClipTM observou-se maiores níveis de espécies do complexo vermelho 60 dias após a colagem. Para os bráquetes convencionais GeminiTM verificou-se diminuição nos níveis de espécies do complexo roxo. Para o bráquete autoligado In-Ovation®R identificou-se diferença significativa para C. rectus 30 dias após a colagem e para S. mutans 60 dias após a colagem. Quando comparou-se os níveis salivares e os in situ, verificou-se maiores níveis de espécies nos bráquetes, in situ, sendo que os autoligados apresentaram os maiores valores. Aumento significante foi verificado para os bráquetes autoligados In-Ovation®R, para S. mutans e L. casei. Após 60 dias da colagem do aparelho ortodôntico observou-se um aumento nos níveis de TNF-&alpha; (p<0.005), em todos os tipos de bráquetes. Considerando-se as condições específicas desse estudo, pode-se concluir que o desenho do bráquete modulou o índice de placa, o volume do fluido crevicular, e os níveis bacterianos do complexo vermelho, sendo o bráquete autoligado SmartClipTM o que apresentou o pior desempenho, nesse aspecto. O bráquete autoligado In-Ovation®R apresentou maiores níveis bacterianos relacionados à cárie dental e espécies do complexo laranja. A concentração de citocinas no fluido crevicular não foi modulada pelo desenho do bráquete, ocorrendo um aumento na concentração de TNF-&alpha; nos três tipos de bráquetes (convencional e autoligados) 60 dias após a colagem. A análise global dos resultados obtidos nos diferentes parâmetros analisados no presente estudo permitiu evidenciar, em geral, melhores resultados clínicos com o bráquete metálico convencional GeminiTM. / The orthodontic appliance promoting several changes in oral cavity according to the variety of solid and elastic materials used in the treatment, leading to the biofilm development. The aim of this study, in vivo, was: 1) Evaluate the periodontal index: Plaque Index (PI), Gingival Index (GI), Gingival Bleeding Index (GBI)and gingival crevicular fluid volume. 2) The levels of cariogenic and periodontopatogenical bacteria in saliva and in two different metallic brackets: self-ligating and conventional, quantify the levels before and 30 and 60 days after bonding orthodontic appliance. 3) The levels of red, orange green and purple complex and others species, in situ and in the saliva. 4) The pro-inflammatory cytokines levels in the gingival crevicular fluid. The sample consisted of 20 patients, aged between 11 and 15 years (mean 13.3 years) who received conventional metal bracket GeminiTM and two different types of self-ligating brackets: In-Ovation®R and SmartClipTM in maxillary incisors and canines. The rates, the volume of the fluid and saliva sample (S0) were obtained before the device (T0), 30 (T1) and 60 (T2) after bonding. A type of each bracket was removed 30 to 60 days after bonding. Data were analyzed statistically using the nonparametric Friedman test, Mann-Whitney and Wilcoxon coefficient and nonparametric Spearman correlation with a significance level of 5 %. The cytokine levels was analyzed by the mixed models, follow to the Tukey test. There was no correlation among the scores of crowding, overjet and overbite with the scores of plaque index (PI), gingival index (GI), gingival bleeding index (GBI) and volume of crevicular fluid at the initial time T0 (p>0.05). There was a significantly difference in PI and crevicular fluid volume, when compared each bracket separately, only the teeth that received self-ligating bracket SmartClipTM, between times T0-T2 (p<0.05). We identified, in the saliva, the presence of 21, bacterial species, of the 22 analyzed; 4 of the 5 fungal species, before bonding the orthodontic appliance. In situ, to the SmartClipTM the highest levels were observed to the red complex 60 days after bonding. To the GeminiTM a decreased to the purple complex was observed when compared 30 and 60 days after bonding. The In-Ovation®R showed a significantly difference to C. rectus, 30 days after bonding. S. mutans, 60 days after bonding. 30 days after bonding the microbial levels is highest in the saliva than in situ, the self-ligating brackets present the highest levels than conventional brackets. 60 days after bonding the TNF-&alpha; levels was increased (p<0,05). The microbial levels was highest in the self-ligating brackets than the conventional brackets. The bracket design seems influenced the plaque index, the volume of the crevicular fluid, the microbial adhesion. The levels in situ are highest than in saliva. The TNF-&alpha; levels were increased 60 days after bonding. The bracket design change the PI, gingival crevicular volume and the red complex species, the SmartClipTM showed the worst results in this point. The In-Ovation®R presented the highest levels of the species to the orange complex and cariogenic species. The design didn\'t modulated the cytokine levels, th TNF&alpha;, increased for all brackets. The global analyses of the results allows us to conclude that the GeminiTM conventional bracket showed the best results when compared to the others self-ligating.

Page generated in 0.0635 seconds