• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 74
  • 35
  • 12
  • 10
  • 7
  • 6
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 286
  • 45
  • 33
  • 28
  • 23
  • 22
  • 22
  • 22
  • 21
  • 20
  • 20
  • 18
  • 17
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo comparativo da influência de sais inorgânicos e estabilizadores amínicos bloqueados (HAS) nas propriedades do PMMA e do PVC expostos à radiação Gama

SILVA, William Barbosa da 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T23:16:23Z (GMT). No. of bitstreams: 2 arquivo8669_1.pdf: 563230 bytes, checksum: d4f87fd40a964c6295e219bda66307b2 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Os polímeros PMMA e PVC fabricados no Brasil são utilizados na confecção de artefatos médico-farmacêutico esterilizáveis por radiação ionizante. Contudo, quando esses polímeros são expostos à radiação gama, podem sofrer alterações na sua cadeia principal. Tais alterações acarretam em degradação molecular e conseqüente mudanças nas suas propriedades físicas. Portanto, a estabilização radiolítica do PMMA e do PVC torna-se fundamental para viabilização desses polímeros na fabricação de artefatos radioesterilizáveis. Neste estudo foram testados dois estabilizantes, um aditivo comercial tipo HAS (Hindered Amine Stabilizer) originalmente utilizado na estabilização foto-oxidativa de polímeros e uma mistura de sais inorgânicos (CuCl2/KI) estudada previamente na estabilização termo-oxidativa de sistemas poliméricos. Os resultados encontrados para os sistemas com PMMA mostraram que o HAS incorporado ao sistema na concentração de 0,3% (m/m) confere uma radioproteção de 61%. Este resultado significa uma redução do valor G (cisões/100eV) de 1,23 para 0,48 no intervalo de 0 a 100kGy. Ensaios térmicos mostraram que o HAS na concentração de 0,3% (m/m) também contribui para a estabilização térmica do PMMA. Por outro lado, nenhuma concentração da mistura de sais mostrou-se eficiente na estabilização radiolítica do PMMA. Para os sistemas baseados no PVC, o HAS não apresentou nenhuma ação estabilizante, provavelmente pela ação do HCl liberado na radiólise da matriz polimérica. O sistema com a mistura de sais apresentou o mesmo comportamento de degradação radiolítica do que o sistema controle, contudo a mistura de sais na concentração de 0,5% (m/m) conferiu uma melhora nas propriedades térmicas do PVC, aumentando em 44°C a temperatura de máxima degradação térmica (liberação de HCl) do polímero. Os ensaios mecânicos realizados para os sistemas de PMMA e PVC indicaram que a mistura de sais foi o estabilizante que mais influenciou nas propriedades mecânicas dos polímeros, com destaque na propriedade módulo de elasticidade que para o PVC aumentou em 23% quando comparado com o PVC-controle. Por outro lado, o PMMA-sais tem seu módulo de elasticidade aumentado em 36% em relação ao PMMA-controle. As análises espectroscópicas na região do infravermelho (FT-IR) mostraram que a presença dos estabilizantes (HAS e CuCl2/KI) nos sistemas de PMMA e PVC não modificaram suas estruturas
32

Böjhållfasthet hos PMMA beroende på framställningsmetod, material och slitage efter termocykling. : - / Flexural strengh of PMMA depending on production method, material, and wear after thermocyckling : -

Khadije, Nemany, Awad, Abdallah Mohammed January 2023 (has links)
Aim: The purpose of the study is to investigate the flexural strength of polymers (PMMA) intended for stabilization splints produced by heat-activated polymerization or milling, as well as how the flexural strength is affected wear.   Material and Methods: Twelve rectangular specimens in the dimensions 64 x 10 x 3 mm were produced by milling and divided into two groups: F (milled) and FS (milled subjected to wear testing). Another twelve specimens in the same dimensions were produced by heat-activated polymerization by pressing and divided into two groups: V (heat polymerized) and VS (heat polymerized subjected to wear testing). The specimens were divided into four groups depending on the material and production technique and test method, and subjected to thermocycling, wear and flexural strength test. The result was analyzed with One-way ANOVA, Tukey’s test and a significance level of α = 0.05.   Results: The milled group had a significantly higher flexural strength compared to the other groups (p < 0.05). However, statistically, no significant differences were found between the other groups FS, V and VS (p > 0.05).   Conclusion: The flexural strength of heat-activated and milled PMMA materials was higher than the minimum requirement for flexural strength for occlusal splints, providing mechanical conditions for the materials to be used in the oral environment.   Milled PMMA exhibit higher flexural strength compared to heat-activated PMMA.               Wear (brushing) affect the flexural strength of milled PMMA negatively. / Syfte Syftet med föreliggande studie är att undersöka böjhållfastheten hos polymerer (PMMA)avsedda för stabiliseringsskenor framställda med varmpolymerisering eller fräsning, samthur böjhållfastheten påverkas av slitage. Material och metod Tolv rektangulära provkroppar med måtten 64 x 10 x 3mm framställdes genom fräsningoch delades in i två grupper: F (frästa) och FS (frästa utsatta för slitagetest). Ytterligare tolvprovkroppar i samma mått framställdes genom varmpolymeriserad pressningsteknik ochdelades in i två grupper: V (varmpolymeriserade) och VS (varmpolymeriserade utsatta förslitagetest). Provkropparna delades in i fyra grupper beroende på material,framställningsteknik och testmetod och utsattes för termocykling, slitage ochböjhållfasthetstest. Resultatet analyserades med One-way ANOVA, Tukey’s test ochsignifikansnivån sattes till α = 0,05. Resultat Den frästa gruppen (F) uppvisade signifikant högre böjhållfasthet jämfört med övrigagrupper (p < 0,05). Mellan de andra grupperna FS, V och VS påvisades inga statistisktsignifikanta skillnader (p > 0,05). Slutsats Med reservation för de begränsningar som studien har kan följande slutsats dras: • Böjhållfastheten hos varmpolymeriserad och fräst PMMA är högre än det minimalakravet på böjhållfasthet för PMMA för stabiliseringsskenor, vilket ger materialenmekaniska förutsättningar att användas i den orala miljön. • Fräst PMMA uppvisar högre böjhållfasthet än varmpolymeriserad PMMA. • Slitage (borstning) påverkar böjhållfastheten hos fräst PMMA negativt.
33

Finite Element Analysis Of A Test Specimen For Strength Of A Co-polymer Layer At A Bone-implant Interface

Chhabra, Nitin 01 January 2004 (has links)
The aim of this work is to evaluate the mechanical strength of a co-polymer of 2-hydroxyethylmethacrylate (HEMA) and methylmethacrylate (MMA), so that it can be applied as an interfacial layer between bone cement and steel implants to improve their performance and life. Finite element (FE) analysis techniques are used to assess the behavior of the interface layer under static and dynamic loading conditions. The material property of the co-polymer is a function of its composition and water saturation. The factors affecting the strength of the bone-implant interface are many. Implant interfacial fracture can lead to decreased stability. Fatigue life is a very important process in failure. The results obtained from static and dynamic analyses show that increasing the percentage of HEMA improves the strength of the interface by reducing the stiffness of the implant, absorbing more energy and by reducing the interfacial stress peaks and making the stress distribution more nearly uniform.
34

Impact of packing and processing technique on mechanical properties of acrylic denture base materials

Nejatian, T., Sefat, Farshid, Johnson, T. 04 1900 (has links)
Yes / The fracture resistance of polymethylmethacrylate (PMMA) as the most popular denture base material is not satisfactory. Different factors can be involved in denture fracture. Among them, flexural fatigue and impact are the most common failure mechanisms of an acrylic denture base. It has been shown that there is a correlation between the static strength and fatigue life of composite resins. Therefore, the transverse strength of the denture base materials can be an important indicator of their service life. In order to improve the fracture resistance of PMMA, extensive studies have been carried out; however, only a few promising results were achieved, which are limited to some mechanical properties of PMMA at the cost of other properties. This study aimed at optimizing the packing and processing condition of heat-cured PMMA as a denture base resin in order to improve its biaxial flexural strength (BFS). The results showed that the plain type of resin with a powder/monomer ratio of 2.5:1 or less, packed conventionally and cured in a water bath for 2 h at 95 °C provides the highest BFS. Also, it was found that the performance of the dry heat processor is inconsistent with the number of flasks being loaded.
35

POLYMER EMBOSSING TOOLS FOR RAPID PROTOTYPING OF PLASTIC MICROFLUIDIC DEVICES

NARASIMHAN, JAGANNATHAN 02 September 2003 (has links)
No description available.
36

Synthesis, Structure And Properties Of Polymer Nanocomposites

Zeng, Changchun 04 March 2004 (has links)
No description available.
37

The effect of PMMA stimulated Complement-Macrophage cascade on Osteogenesis of Preosteoblast-like MC3T3-E1 cells on PMMA surface

Zheng, Fengyuan January 2010 (has links)
No description available.
38

Hållfasthet på lagat protesbasmaterial. Termoplast och varmpolymeriserad PMMA lagat med olika material och tekniker

Billsten, Marie, Tudor, Eva January 2012 (has links)
Syfte och nollhypotes: Syftet med föreliggande studie är att testa hållfastheten hos lagat varmpolymeriserad PMMA och termoplast med och utan monomervätning av ytorna som sammanfogas. Samt jämföra termoplast lagad med kallpolymeriserad PMMA och termoplast lagad med tillhörande lagningsmaterial. Nollhypotesen är att det inte finns en signifikant skillnad mellan material och tekniker. Material och metod: 30 stycken provkroppar i varmpolymeriserad PMMA och 40 stycken provkroppar i termoplast tillverkades. Varje grupp bestod utav 10 provkroppar. Som lagningsmaterial användes kallpolymeriserad PMMA och termoplasts egna lagningsmaterial. Provkropparna kapades och kanten fasades till 45°. En grupp i termoplast respektive varmpolymeriserad PMMA behandlades med monomervätska innan lagning. Alla provkroppar förvarades i destillerat vatten och termocyklades i 5000 cykler med temperatur mellan 5±2°C och 55±2°C. Trepunktsböjhållfasthetstest utfördes. Värdet registrerades och resultatet analyserades med hjälp av One-way ANOVA, Tukey. Signifikansnivån sattes till α=0,05. Resultat: Varmpolymeriserad PMMA utan monomervätning visade signifikant lägre hållfasthet än varmpolymeriserad PMMA med monomervätning, varmpolymeriserad PMMA kontroll och termoplast kontrollgrupp. Termoplast lagat med Qu-resin visade en betydlig lägre hållfasthet jämfört med termoplast lagad med kallpolymeriserad PMMA. Dominerande fraktur för alla grupper var kohesiv med brott i lagningsmaterialet. Slutsats: Vätning av varmpolymeriserad PMMA med monomervätska innan lagning ger en signifikant bättre böjhållfasthet än lagning av varmpolymeriserad PMMA utan vätning. Vätning med monomervätska på termoplast ger ingen signifikant effekt på hållfastheten. Lagning med kallpolymeriserad PMMA ger bättre böjhållfasthet än Qu-resin på termoplast. Därmed kan nollhypotesen förkastas.
39

Mechanische Spektroskopie an PMMA-Systemen: Nichtlineares Verhalten und UV-aktive Blockcopolymere / Mechanical spectroscopy of PMMA-systems: Nonlinear behavior and UV-active blockcopolymers

Finkhäuser, Stefanie 07 December 2016 (has links)
No description available.
40

Processo de fabricação de mini e microdispositivos fluídicos por ablação a laser de dióxido de carbono / A fabrication process of mini- and microfluidic device using carbon dioxide laser

Costa, Eric Tavares da 03 December 2009 (has links)
Este trabalho descreve o desenvolvimento de um processo de fabricação de mini e microdispositivos fluídicos baseado na utilização de um equipamento de usinagem a laser de CO2 para criação de relevos sobre base de poli(metacrilato de metila) e na selagem térmica contra igual material. Inicialmente, o equipamento laser foi detalhadamente caracterizado, o que possibilitou elaborar métodos para a construção de microcanais de forma mais eficiente e com menores chances de defeitos. Tipicamente, os canais apresentaram seção transversal triangular em torno de 200 µm de largura e 100 µm de profundidade, sendo possível, no entanto, criar canais com outras características. A etapa de selagem entre a tampa e a base que apresentou melhores resultados consiste em pressurização acima de 6 kgf·cm-2 e aquecimento a 110 ºC durante 45 minutos, seguido de resfriamento por 1 h. Os microcanais selados por esta técnica, resistiram a pressões superiores a 3,5·kgf·cm-2. O processo desenvolvido se mostrou adequado para a criação de protótipos, sendo também suas principais características: (1) a facilidade de incorporação de regiões de grandes dimensões (como reservatórios) em conjunto com os microcanais, (2) número reduzido de etapas de produção e (3) boa uniformidade química da parede interna dos canais, o que é particularmente interessante para microdispositivos aplicados à Química Analítica / A microfabrication process based machining using CO2 laser on poly(methyl methacrylate) and thermal sealing is described. Initially, the laser equipment was characterized in detail, which allowed developing strategies for the construction of microchannels more efficiently and less failure-prone. Typically, the channels had a triangular cross section around 200 µm in width and 100 µm in depth. It is possible, however, create channels with other features. The sealing step that showed better results consists in to pressurize at 6 kgf·cm-2 and heating at 110 °C during 45 minutes, followed by natural cooling for 1 h. The microchannels sealed by using this procedure resisted pressures above 3.5 kgf·cm-2. The process proved to be adequate for prototyping and also has other main features: (1) easiness of incorporation of large regions (such as reservoirs) together with the microchannel; (2) reduced number of manufacturing steps and (3) good chemical uniformity of the inner wall of the channel, which is particularly interesting for microdevices applied to Analytical Chemistry.

Page generated in 0.0175 seconds