• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 6
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 55
  • 18
  • 18
  • 15
  • 14
  • 11
  • 11
  • 11
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

On monitoring methods and load modeling to improve voltage stability assessment efficiency

Genet, Benjamin 02 October 2009 (has links)
Power systems must face new challenges in the current environment. The energy market liberalization and the increase in the loading level make the occurrence of instability phenomena leading to large blackouts more likely. Existing tools must be improved and new tools must be developed to avoid them.<p><p>The aim of this thesis is the improvement of the voltage stability assessment efficiency. Two orientations are studied: the monitoring methods and the load modeling.<p><p>The purpose of the monitoring methods is to evaluate the voltage stability using only measurements and without running simulations. <p><p>The first approach considered is local. The parameters of the Thevenin equivalent seen from a load bus are assessed thanks to a stream of local voltage and current measurements. Several issues are investigated using measurements coming from complete time-domain simulations. The applicability of this approach is questioned.<p><p>The second approach is global and uses measurements acquired by a Wide-Area Measurement System (WAMS). An original approach with a certain prediction capability is proposed, along with intuitive visualizations that allow to understand the deterioration process leading to the collapse.<p><p>The load modeling quality is certainly the weak point of the voltage security assessment tools which run simulations to predict the stability of the power system depending on different evolutions. Appropriate load models with accurate parameters lead to a direct improvement of the prediction precision.<p><p>An innovative procedure starting from data of long measurement campaigns is proposed to automatically evaluate the parameters of static and dynamic load models. Real measurements taken in the Belgian power system are used to validate this approach.<p> / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
52

Development of Hardware in the Loop Real-Time Control Techniques for Hybrid Power Systems Involving Distributed Demands and Sustainable Energy Sources

Mazloomzadeh, Ali 07 November 2014 (has links)
The future power grid will effectively utilize renewable energy resources and distributed generation to respond to energy demand while incorporating information technology and communication infrastructure for their optimum operation. This dissertation contributes to the development of real-time techniques, for wide-area monitoring and secure real-time control and operation of hybrid power systems. To handle the increased level of real-time data exchange, this dissertation develops a supervisory control and data acquisition (SCADA) system that is equipped with a state estimation scheme from the real-time data. This system is verified on a specially developed laboratory-based test bed facility, as a hardware and software platform, to emulate the actual scenarios of a real hybrid power system with the highest level of similarities and capabilities to practical utility systems. It includes phasor measurements at hundreds of measurement points on the system. These measurements were obtained from especially developed laboratory based Phasor Measurement Unit (PMU) that is utilized in addition to existing commercially based PMU’s. The developed PMU was used in conjunction with the interconnected system along with the commercial PMU’s. The tested studies included a new technique for detecting the partially islanded micro grids in addition to several real-time techniques for synchronization and parameter identifications of hybrid systems. Moreover, due to numerous integration of renewable energy resources through DC microgrids, this dissertation performs several practical cases for improvement of interoperability of such systems. Moreover, increased number of small and dispersed generating stations and their need to connect fast and properly into the AC grids, urged this work to explore the challenges that arise in synchronization of generators to the grid and through introduction of a Dynamic Brake system to improve the process of connecting distributed generators to the power grid. Real time operation and control requires data communication security. A research effort in this dissertation was developed based on Trusted Sensing Base (TSB) process for data communication security. The innovative TSB approach improves the security aspect of the power grid as a cyber-physical system. It is based on available GPS synchronization technology and provides protection against confidentiality attacks in critical power system infrastructures.
53

Voltage Stability Analysis of Unbalanced Power Systems

Santosh Kumar, A January 2016 (has links) (PDF)
The modern day power system is witnessing a tremendous change. There has been a rapid rise in the distributed generation, along with this the deregulation has resulted in a more complex system. The power demand is on a rise, the generation and trans-mission infrastructure hasn't yet adapted to this growing demand. The economic and operational constraints have forced the system to be operated close to its design limits, making the system vulnerable to disturbances and possible grid failure. This makes the study of voltage stability of the system important more than ever. Generally, voltage stability studies are carried on a single phase equivalent system assuming that the system is perfectly balanced. However, the three phase power system is not always in balanced state. There are a number of untransposed lines, single phase and double phase lines. This thesis deals with three phase voltage stability analysis, in particular the voltage stability index known as L-Index. The equivalent single phase analysis for voltage stability fails to work in case of any unbalance in the system or in presence of asymmetrical contingency. Moreover, as the system operators are giving importance to synchrophasor measurements, PMUs are being installed throughout the system. Hence, the three phase voltages can be obtained, making three phase analysis easier. To study the effect of unbalanced system on voltage stability a three phase L-Index based on traditional L-Index has been proposed. The proposed index takes into consideration the unbalance resulting due to untransposed transmission lines and unbalanced loads in the system. This index can handle any unbalance in the system and is much more realistic. To obtain bus voltages during unbalanced operation of the system a three phase decoupled Newton Raphson load ow was used. Reactive power distribution in a system can be altered using generators voltage set-ting, transformers OLTC settings and SVC settings. All these settings are usually in balanced mode i.e. all the phases have the same setting. Based on this reactive power optimization using LP technique on an equivalent single phase system is proposed. This method takes into account generator voltage settings, OLTC settings of transformers and SVC settings. The optimal settings so obtained are applied to corresponding three phase system. The effectiveness of the optimal settings during unbalanced scenario is studied. This method ensures better voltage pro les and decrease in power loss. Case studies of the proposed methods are carried on 12 bus and 24 bus EHV systems of southern Indian grid and a modified IEEE 30 bus system. Both balanced and unbalanced systems are studied and the results are compared.
54

Multi-dimensional direct-sequence spread spectrum multiple-access communication with adaptive channel coding

Malan, Estian 25 October 2007 (has links)
During the race towards the4th generation (4G) cellular-based digital communication systems, a growth in the demand for high capacity, multi-media capable, improved Quality-of-Service (QoS) mobile communication systems have caused the developing mobile communications world to turn towards betterMultiple Access (MA) techniques, like Code Division Multiple Access (CDMA) [5]. The demand for higher throughput and better QoS in future 4G systems have also given rise to a scheme that is becoming ever more popular for use in these so-called ‘bandwidth-on-demand’ systems. This scheme is known as adaptive channel coding, and gives a system the ability to firstly sense changes in conditions, and secondly, to adapt to these changes, exploiting the fact that under good channel conditions, a very simple or even no channel coding scheme can be used for Forward Error Correction(FEC). This will ultimately result in better system throughput utilization. One such scheme, known as incremental redundancy, is already implemented in the Enhanced Data Rates for GSM Evolution (EDGE) standard. This study presents an extensive simulation study of a Multi-User (MU), adaptive channel coded Direct Sequence Spread Spectrum Multiple Access (DS/SSMA) communication system. This study firstly presents and utilizes a complex Base Band(BB) DS/SSMA transmitter model, aimed at user data diversity [6] in order to realize the MU input data to the system. This transmitter employs sophisticated double-sideband (DSB)Constant-Envelope Linearly Interpolated Root-of-Unity (CE-LI-RU) filtered General Chirp-Like (GCL) sequences [34, 37, 38] to band limit and spread user data. It then utilizes a fully user-definable, complex Multipath Fading Channel Simulator(MFCS), first presented by Staphorst [3], which is capable of reproducing all of the physical attributes of realistic mobile fading channels. Next, this study presents a matching DS/SSMA receiver structure that aims to optimally recover user data from the channel, ensuring the achievement of data diversity. In order to provide the basic channel coding functionality needed by the system of this study, three simple, but well-known channel coding schemes are investigated and employed. These are: binary Hamming (7,4,3) block code, (15,7,5) binary Bose-Chadhuri-Hocquenghem (BCH) block code and a rate 1/3 <i.Non-Systematic (NS) binary convolutional code [6]. The first step towards the realization of any adaptive channel coded system is the ability to measure channel conditions as fast as possible, without the loss of accuracy or inclusion of known data. In 1965, Gooding presented a paper in which he described a technique that measures communication conditions at the receiving end of a system through a device called a Performance Monitoring Unit (PMU) [12, 13]. This device accelerates the system’sBit Error Rate (BER) to a so-called Pseudo Error Rate(PER) through a process known as threshold modification. It then uses a simple PER extrapolation algorithm to estimate the system’s true BER with moderate accuracy and without the need for known data. This study extends the work of Gooding by applying his technique to the DS/SSMA system that utilizes a generic Soft-Output Viterbi Algorithm(SOVA) decoder [39] structure for the trellis decoding of the binary linear block codes [3, 41-50], as well as binary convolutional codes mentioned, over realistic MU frequency selective channel conditions. This application will grant the system the ability to sense changes in communication conditions through real-time BER measurement and, ultimately, to adapt to these changes by switching to different channel codes. Because no previous literature exists on this application, this work is considered novel. Extensive simulation results also investigate the linearity of the PER vs. modified threshold relationship for uncoded, as well as all coded cases. These simulations are all done for single, as well as multiple user systems. This study also provides extensive simulation results that investigate the calculation accuracy and speed advantages that Gooding’s technique possesses over that of the classic Monte-Carlo technique for BER estimation. These simulations also consider uncoded and coded cases, as well as single and multiple users. Finally, this study investigates the experimental real-time performance of the fully functional MU, adaptive coded, DS/SSMA communication system over varying channel conditions. During this part of the study, the channel conditions are varied over time, and the system’s adaptation (channel code switching) performance is observed through a real-time observation of the system’s estimated BER. This study also extends into cases with multiple system users. Since the adaptive coded system of this study does not require known data sequences (training sequences), inclusion of Gooding’s technique for real-time BER estimation through threshold modification and PER extrapolation in future 4G adaptive systems will enable better Quality-of-Service (QoS) management without sacrificing throughput. Furthermore, this study proves that when Gooding’s technique is applied to a coded system with a soft-output, it can be an effective technique for QoS monitoring, and should be considered in 4G systems of the future. / Dissertation (MEng (Computer Engineering))--University of Pretoria, 2007. / Electrical, Electronic and Computer Engineering / MEng / unrestricted
55

A Wide-Area Perspective on Power System Operation and Dynamics

Gardner, Robert Matthew 23 April 2008 (has links)
Classically, wide-area synchronized power system monitoring has been an expensive task requiring significant investment in utility communications infrastructures for the service of relatively few costly sensors. The purpose of this research is to demonstrate the viability of power system monitoring from very low voltage levels (120 V). Challenging the accepted norms in power system monitoring, the document will present the use of inexpensive GPS time synchronized sensors in mass numbers at the distribution level. In the past, such low level monitoring has been overlooked due to a perceived imbalance between the required investment and the usefulness of the resulting deluge of information. However, distribution level monitoring offers several advantages over bulk transmission system monitoring. First, practically everyone with access to electricity also has a measurement port into the electric power system. Second, internet access and GPS availability have become pedestrian commodities providing a communications and synchronization infrastructure for the transmission of low-voltage measurements. Third, these ubiquitous measurement points exist in an interconnected fashion irrespective of utility boundaries. This work offers insight into which parameters are meaningful to monitor at the distribution level and provides applications that add unprecedented value to the data extracted from this level. System models comprising the entire Eastern Interconnection are exploited in conjunction with a bounty of distribution level measurement data for the development of wide-area disturbance detection, classification, analysis, and location routines. The main contributions of this work are fivefold: the introduction of a novel power system disturbance detection algorithm; the development of a power system oscillation damping analysis methodology; the development of several parametric and non-parametric power system disturbance location methods, new methods of power system phenomena visualization, and the proposal and mapping of an online power system event reporting scheme. / Ph. D.

Page generated in 0.0164 seconds