• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 142
  • 142
  • 122
  • 121
  • 54
  • 53
  • 40
  • 35
  • 35
  • 32
  • 30
  • 29
  • 28
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

The effect of instruction on sandhi-forms on L2 listening comprehension tasks

Perucci, Margareth January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão. Programa de Pós-Graduação em Letras/Inglês e Literatura Correspondente. / Made available in DSpace on 2013-07-16T02:36:55Z (GMT). No. of bitstreams: 1 229610.pdf: 1343773 bytes, checksum: fb49ebf2713015919e2bb7513f32d96a (MD5) / Este estudo investiga o efeito da instrução de formas sândi (somente sândi externo) dentro de tarefas de compreensão oral em aprendentes Brasileiros estudando Inglês como Língua Estrangeira (LE). Os aprendentes deste estudo são alunos de nível Intermediário de uma escola de línguas do estado de São Paulo. Foi a partir das dificuldades apresentadas por aprendentes ao realizar tarefas de compreensão oral em LE (quando tais tarefas não eram demasiadamente simplificadas), que surgiu o interesse por este estudo. Participaram dele um grupo que recebeu instrução somente em tarefas de preparação para a compreensão (o grupo controle - CG), e um grupo que recebeu instrução em formas sândi (chamado de grupo de tratamento -TG). O estudo analisa o ensino das formas sândi sob três aspectos: A instrução de formas sândi (assimilação, apagamento, redução e ligação) em si; o papel da sistematicidade no ensino das mesmas; e a comparação entre tarefas focando compreensão oral de formas sândi e tarefas focando metalinguagem de formas sândi. Os resultados mostram que há ganhos maiores para os aprendentes que recebem instrução em formas sândi, do que para os aprendentes que realizam tarefas de preparação para a compreensão. O estudo mostra também as implicações pedagógicas de tais resultados e sugestões para pesquisas na área. This study investigates the effects of instruction on sandhi forms (external sandhi only) on listening comprehension tasks in Brazilian learners studying English as a Foreign Language (EFL). The learners in this study are Intermediate-level students at a language school in São Paulo. The study departed from students' difficulties to carry out EFL listening comprehension tasks (when the tasks were not over simplified). The participants in this study were divided into two groups. Students who received instruction on pre-listening tasks (they were the Control Group -CG) and students who received instruction on sandhi-forms (they were the treatment group - TG). The study looks at the teaching of sandhi-forms from three aspects: the instruction on sandhi-forms (assimilation, deletion, reduction and linking) itself; the teaching of sandhi forms in a systematic way; the contrast between listening comprehension tasks focusing on sandhi-forms and metalanguage tasks focusing on sandhi-forms. Results point to more gains to students who received instruction on sandhi , than to those students who worked on pre-listening tasks. The study also shows the pedagogical implications of the results, and suggestions for further research in the field.
12

Effects of noticing on the oral output in english as a foreign language

Nogueira, Viviani Catia January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-graduação em Inglês: Estudos Linguísticos e Literários, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:37:18Z (GMT). No. of bitstreams: 1 328558.pdf: 3476924 bytes, checksum: aaee51083c55b8a7846c0b383726f6dc (MD5) Previous issue date: 2014 / Schmidt's (1986, 1990, 1995, 2010) Noticing Hypothesis states that the learning of a linguistic item in an L2 occurs if the item is registered by the learner with some degree of awareness, that is, when the item is noticed. Based on this claim, the present study, which is nested in the interface between language and pedagogy, investigates the effects of noticing on the oral output of learners of English as a foreign language. The grammatical structure selected for this study was the absence and the obligatory use of the definite article "the", in three realizations: the absence of "the" to convey genericity, the obligatory use of "the+singular noun' to convey genericity, and the use of "the+noun made definite by the addition of a phrase" to convey specificity. In order to have learners focus their attention on the target structure, the pedagogical technique of input enhancement was applied through the underlining of the grammatical structure. Forty-eight participants of a language school in Rio Negrinho-SC completed (1) a personal and language background questionnaire, took both (2) a written and (3) an oral pretest assessing their knowledge of the target structure, carried out (4) four speaking activities as treatment, responded to (5)four retrospective interviews, one after each treatment session, and took both (6) a written and (7) an oral posttest. The results indicated a statistically significant increase from pre to posttests, in learners' accuracy in the use of the target structure, both in the written and in theoral tests. In addition, a moderate correlation between noticing and learning of the target structure was obtained from the data. These results are interpreted as evidence that noticing has effects on the oral output of learners of English as a foreign language. / Apresentada por Schmidt (1986, 1990, 1995, 2010) a Hipótese da Percepção Consciente propõe que a aprendizagem de um item linguístico numa segunda língua ocorre se o item é registrado pelo aprendiz com algum grau de consciência, isto é, se o item é percebido conscientemente. Com base nessa afirmação, este estudo, que se utilizada interface entre a linguagem e a pedagogia, investiga os efeitos da percepção consciente na produção oral de aprendizes de Inglês como língua estrangeira. A estrutura gramatical selecionada para este estudo foi a ausência e o uso obrigatório do artigo definido "the", em três realizações: a ausência do artigo definido para expressar genericidade, o uso obrigatório do artigo definido+sintagma nominal no singular para expressar genericidade, e o uso obrigatório do artigo definido+substantivo definido por sintagma para expressar especificidade. Com o objetivo de fazer com que o aprendiz focasse a sua atenção na estrutura alvo, o destaque do insumo, através do seu sublinhamento, foi aplicado como técnica pedagógica. Quarenta e oito participantes de uma escola de idiomas em Rio Negrinho-SC passaram pelos seguintes procedimentos: completaram (1) um questionário de informações pessoais e de experiência linguística; fizeram (2) um pré teste escrito e (3) um pré-teste oral, ambos para verificação do conhecimento do participante em relação à estrutura alvo; (4) quatro atividades de conversação, como tratamento; responderam a (5) quatro entrevistas retrospectivas, uma após cada sessão de tratamento, para possibilitar o acesso à percepção consciente do aprendiz; e fizeram (6)um pós-teste escrito e (7) um pós-teste oral. Os resultados indicaram um aumento estatisticamente significativo na média dos pré-testes para os pós-testes, em relação à acurácia no uso da estrutura alvo, tanto para os testes escritos quanto para os orais. Além disso, os resultados sugeriram a existência de uma correlação moderada entre percepção consciente e aprendizagem da estrutura alvo. Esses resultados foram interpretados como evidência de que a percepção consciente causa efeitos na produção oral de aprendizes de inglês como língua estrangeira.
13

Efeito de diferentes situações de escuta no masking release para a fala

Pacífico, Fernando Augusto 28 February 2014 (has links)
Submitted by Ramon Santana (ramon.souza@ufpe.br) on 2015-03-13T19:43:56Z No. of bitstreams: 2 DISSERTAÇÃO Fernando Augusto Pacífico.pdf: 4235551 bytes, checksum: de37fb84f7998b88d5d0326c8237bf93 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-13T19:43:56Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Fernando Augusto Pacífico.pdf: 4235551 bytes, checksum: de37fb84f7998b88d5d0326c8237bf93 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-02-28 / National Institute of Health e Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Embora muito se tenha estudado sobre o masking release ou benefício causado pela modificação do mascaramento modulado, estudos recentes tem apontado a relação de dependência entre este e a relação fala-ruído. Dessa forma, o objetivo principal desta dissertação foi investigar o masking release em diferentes situações de escuta com o material de fala do teste HINT versão do Português Brasileiro em adultos jovens com audição normal. Foi realizada no período entre julho de 2012 a julho de 2013, no Laboratório de Audiologia da Clínica Escola do Curso de Fonoaudiologia da Universidade Federal de Pernambuco (UFPE), situado no Hospital das Clínicas da UFPE. A pesquisa foi composta por 55 adultos nativos do Português do Brasil com limiars auditivos tonai ≤ 20 dB NA, com idade entre 17 a 35 anos, de ambos os sexos. O primeiro experimento verificou o efeito de diferentes frequencias de modulação do mascaramento no masking release para a fala. Os resultados mostraram a magnitude do masking relase para sentenças do HINT na versão do Português Brasileiro não se diferencia com taxas de modulação em amplitude entre 4 Hz e 32 Hz. No entanto, quando a taxa é elevada a 64 Hz, a magnitude do masking release diminui. O segundo experimento mediu a função desempenho-intensidade em presença de ruído estável (com espectro de fala) e modulado (por uma onda quadrática a uma taxa de 10 Hz). Os resultados mostraram curvas psicométrica menos íngremes quando o ruído era modulado. O terceiro experimento mediu as relações fala-ruído em função da compressão da fala em tempo (0%, 33% e 50% de compressão) em ambos os tipos de ruído. Os limiares aumentaram com o aumento da compressão da fala em tempo em ambos as condições, no entanto, foi mais acentuado para o ruído modulado. Portanto, o beneficio do mascaramento modulado diminuiu com o aumento da compressão temporal da fala. Este padrão de resultado sustenta a hipótese de que, em condições de teste, a redução do benefício do mascaramento modulado pode ser devido a RFR elevadas.
14

HINT: um estudo sobre os critérios de julgamento no Brasil

Melo, Rafaela do Couto 31 January 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2015-05-12T16:40:31Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Rafaela do Couto Melo2.pdf: 476542 bytes, checksum: c17fc35ff6b9babf019ae0d6a6255b37 (MD5) / Made available in DSpace on 2015-05-12T16:40:31Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Rafaela do Couto Melo2.pdf: 476542 bytes, checksum: c17fc35ff6b9babf019ae0d6a6255b37 (MD5) Previous issue date: 2015 / Introdução: A capacidade em perceber os sons da fala possibilita ao homem comunicar-se de forma eficiente. Esse aspecto deve ser considerado na avaliação dos distúrbios da comunicação humana. O teste Hint foi adaptado para o português brasileiro e faz uso de sentenças para avaliar o reconhecimento de fala em silêncio, e em presença de ruído competitivo. O teste pode ser uma ferramenta clínica importante, no entanto, não se observa o uso do Hint em prática clínica audiológica no Brasil. Um dos motivos deve ser a falta de padronização em alguns aspectos do teste, inclusive, o julgamento das respostas. Objetivo: Analisar os diferentes critérios de julgamento de respostas obtidas de indivíduos submetidos à pesquisa de limiares de reconhecimento das sentenças do Hint em português brasileiro. Método: A pesquisa foi realizada no Laboratório de Audiologia da Universidade Federal de Pernambuco com 30 adultos jovens (três grupos de 10 pessoas), entre 18 e 25 anos, de ambos os sexos, com audição normal. Os indivíduos foram submetidos ao teste de reconhecimento de fala em presença de ruído competitivo com o uso das sentenças do Hint adaptado para o português brasileiro. Foram determinados limiares de reconhecimento de fala em presença de ruído através da utilização de três critérios de julgamento publicados na literatura brasileira. Foi realizada uma análise de variação única para comparar as médias dos limiares entre os três grupos. A probabilidade máxima de erro para rejeitar a hipótese nula foi 5%. Resultados: As médias e os desvios-padrão dos limiares, respectivamente, foram: 59,90 dB ±1,43; 59,60 dB ± 0,53 e 59,95 dB ± 0,6. Não houve diferença estatisticamente significativa entre as médias (F=0,398; p>0,05). Conclusão: Independente do critério de julgamento utilizado, as respostas obtidas de indivíduos submetidos à pesquisa de limiares de reconhecimento de sentenças em presença de ruído, foram semelhantes.
15

Testes de percepção de fala nos centros de implante coclear: conhecendo a realidade nacional

FARIA, Luisa Robalinho de 26 August 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-08-04T14:24:54Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE - Mestrado - Luisa Robalinho - TESTES DE PERCEPÇÃO DE FALA NOS CENTROS DE IMPLANTE COCLEAR- .pdf: 3197144 bytes, checksum: 6f086ea2faf07950313de0d462c86015 (MD5) / Made available in DSpace on 2017-08-04T14:24:54Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE - Mestrado - Luisa Robalinho - TESTES DE PERCEPÇÃO DE FALA NOS CENTROS DE IMPLANTE COCLEAR- .pdf: 3197144 bytes, checksum: 6f086ea2faf07950313de0d462c86015 (MD5) Previous issue date: 2016-08-26 / Os testes de percepção de fala são utilizados na avaliação dos pacientes com perda auditiva de severa a profunda, na indicação da cirurgia de implante coclear, no acompanhamento da reabilitação auditiva e na programação dos processadores de fala. Este trabalho tem por objetivo identificar os testes usados no Brasil e descrever como são empregados nos centros de implante cadastrados ao Sistema Único de Saúde. É um estudo do tipo descritivo, observacional, transversal e quantitativo, desenvolvido no Departamento de Fonoaudiologia da Universidade Federal de Pernambuco. Participaram da pesquisa fonoaudiólogos, lotados nos centros de implante cadastrados no SUS. Os dados foram colhidos por meio de um questionário enviado por e-mail. Dos 26 centros de IC, 17 responderam à pesquisa. Um deles foi excluído, e, em três centros, dois fonoaudiólogos responderam, totalizando um total de 19 participantes. Foi percebida uma variabilidade de respostas entre os centros e dentro de um mesmo serviço. Apenas os sons do Ling e os testes com sentenças foram referidos por 100% dos fonoaudiólogos. Essa variação ocorreu em relação ao tipo de teste, frequência da aplicação, momento em que foi utilizado, intensidade de sinal e forma de aplicação. Concluiu-se que não há uniformidade entre os centros no uso desse material, o que dificulta a avaliação comparativa entre centros, tanto para fins de pesquisa, quanto para avaliação dos dados pelo Ministério da Saúde. / Speech perception tests are employed to assess hearing abilities of patients with severe to profound hearing loss, for cochlear implants (CI) indications, to follow hearing abilities up in post-operative and to program speech processors. This research has the objective to find out which tests are used in Brazil and describe how they are employed in cochlear implant centers registered in Brazil's Public Health System. It's a descriptive, observacional, cross-sectional and quantitative research, developed in the Speech Therapist Department, Pernambuco Federal University. Speech Therapist working in cochlear implants centers registered in Brazil's Public Health System participated in the research. Data was collected through a questionnaire sent by e-mail. 17 of the 26 CI centers answered the research. One of the answers was excluded and in three centers two speech therapist answered, making a total of 19 participants. Variances of answers were found. Only Ling's sounds and sentences’ tests were mentioned by 100% of the speech therapist. This variance was related to the kind of test, frequency and moment of application, intensity of signal and how it was applied. There is no uniformity between centers in speech perception tests, making it difficult to compare centers for research purposes and to assess data for the Health Ministry.
16

Crianças usuárias de implante coclear com atraso do desenvolvimento da percepção auditiva da fala: análise dos fatores que influenciam o desempenho / Factors influencing cochlear implant outcomes analysis in children with auditory speech perception developmental delay

Raquel Franco Stuchi Siagh 11 May 2018 (has links)
Algumas crianças usuárias de implante coclear (IC) não desenvolvem a habilidade de reconhecimento auditivo em conjunto aberto, mesmo após um longo período de uso do dispositivo e mesmo sem apresentar fatores na etapa pré-operatória que sugiram esse prognóstico. Os fatores que influenciam o desempenho dessas crianças atuam de maneira complexa também nas etapas intra e pós-operatórias e o conhecimento profundo dos mesmos é fundamental para direcionar condutas em busca de uma habilitação auditiva de sucesso. Sobre a atuação fonoaudiológica na etapa pós-operatória, o uso de marcadores clínicos de desempenho permite a identificação de atrasos no desenvolvimento de percepção da fala e linguagem. Alguns fatores já são descritos como negativamente influentes, mas, estudos que realizem análises profundas das causas dos mesmos são necessários. Objetivos: a) descrever o desenvolvimento das habilidades auditivas de crianças que não apresentaram a habilidade de reconhecimento auditivo em conjunto aberto ao final de cinco anos de uso do IC; b) analisar os fatores que influenciam o desenvolvimento da percepção auditiva da fala, considerando este grupo de crianças, e a atuação fonoaudiológica na etapa pós-operatória. Metodologia: estudo exploratório, retrospectivo longitudinal por meio de análise de prontuário realizado no Centro de Pesquisas Audiológicas/Setor de IC do HRAC-USP. Foram analisadas 21 crianças. O desenvolvimento das habilidades auditivas foi descrito por meio das Categorias de Audição (GEERS, 1994). Os fatores analisados foram: fatores relacionados aos eletrodos e problemas relacionados ao mapeamento; interrupção do uso do implante coclear; uso assistemático do dispositivo; faltas no acompanhamento pós-operatório; fatores relacionados à terapia fonoaudiológica e fatores relacionados ao neurodesenvolvimento. Foi realizada análise qualitativa dos resultados por meio da metodologia de análise temática e a análise quantitativa, por meio da estatística descritiva e inferencial. Resultados e Discussão: desenvolvimento auditivo houve uma tendência discreta de curva crescente ao longo dos anos de uso, com oscilações; o desempenho ao final do período estudado, pôde ser representado pela Categoria de Audição 2 detecção de padrões de percepção. Para crianças implantadas unilateralmente, até os 36 meses e sem fatores influentes na etapa pré-operatória pode-se esperar que atinjam a categoria 3 a partir de 5 meses de uso do IC, sendo um alerta se não a alcançarem até os 12 meses de uso. Os fatores interrupção do uso/uso assistemático foram os mais frequentemente observados e as causas foram relacionadas ao funcionamento do IC, comportamento da família e recusa da criança; o tempo de interrupção foi significativamente maior quando problemas do componente externo aconteceram após o término de sua garantia (p=0,001). Houve tendência de indivíduos que moravam mais longe do hospital faltarem mais aos retornos, entretanto, a associação não foi significativa. Conclusão: foi possível obter um padrão de desenvolvimento auditivo do grupo estudado e os resultados podem ser utilizados como marcadores clínicos de desempenho. A análise dos fatores pôde nortear discussões referentes às possíveis condutas fonoaudiológicas no acompanhamento pós-operatório da criança usuária de implante coclear e pode servir como base para investigações de fatores na prática clínica, bem como futuras investigações científicas. / There are some pediatric cochlear implant (CI) patients who do not develop open set speech recognition even after a long period of device use, and even without presenting factors in the preoperative stage suggestive of this prognosis. The factors that influence the outcomes of these children act in a complex way also in the intra and postoperative stages and the deep knowledge of them is fundamental to conduct intervetion to achieve a successful auditory habilitation. Regarding audiological postoperative follow up, the use of benchmarkers allows the identification of delayed speech perception and language development. Some factors are already described as negatively influential, but an in-depth analysis studies of their causes are needed. Objectives: a) to describe the auditory skills development of children who did not achieve open set speech recognition at the end of five years of CI use; b) to analyze the factors that influence the auditory speech perception development during the five years of CI use, considering audiological postoperative follow up. Methods: exploratory, retrospective longitudinal study by chart analysis, performed at the CPA/Seção de IC of HRAC-USP. Twenty-one children were analyzed. The development of hearing abilities was described through the Hearing Categories (GEERS, 1994). The factors analyzed were: factors related to the electrodes and problems related to the mapping; use interruption of the device; unsystematical use of the device; missed postoperative follow-up; factors related to the auditory therapy and factors related to neurodevelopment. A qualitative analysis of the results was performed using thematic analysis methodology and quantitative analysis, using descriptive and inferential statistics. Results and Discussion: auditory development there was a discrete trend of increasing curve over the years of use, with oscillations; the performance at the end of the studied period could be represented by the Hearing Category \"2\" detection of perception patterns. For unilaterally implanted children, who do the activation until 36 months of age and without influential factors in the preoperative stage, it can be expected that they reach category 3 after 5 months of CI use, and it can be considered a red flag if they are not reached it until the 12 months of use .The interruption/unsystematic use were the most frequently observed factors and the causes were related to the functioning of the CI, family behavior and refusal of the child; the interruption time was significantly higher when problems of the external component occurred after the end of its warranty (p=0.001). There was a tendency for individuals living farther from the hospital to miss more returns, however, the association was not significant. Conclusion: it was possible to obtain an auditory developmental pattern of the studied group and the results can be used as benchmarks of performance. The analysis of the factors could guide discussions regarding possible audiological intervention in the postoperative follow-up of the cochlear implanted child and can serve as guide for investigations of factors in clinical practice, as well as future investigations.
17

"Julgamento do comportamento vocal de jornalistas em diferentes estilos de notícias e seus correlatos acústicos". / Judgment of the vocal behavior of journalists in different styles of news and its acoustic correlations

Adriana Campos Balieiro Panico 29 April 2005 (has links)
Investigaram-se a identificação de diferentes estilos de emissões do telejornalismo classificados em: neutro, sério e descontraído, e seus correlatos acústicos. Apresentadores experientes, de ambos os sexos, com atuação constante em telejornais de rede, gravaram um texto, de mesmo conteúdo semântico, por três vezes, nos três estilos de emissão. A partir dessa gravação, foi separado o áudio em CD, em formato wave, para que se procedesse à análise acústica da amostragem, avaliando os parâmetros acústicos de freqüência, intensidade e duração da emissão; por meio do software Dr. Speech 4.0. Em outro CD, em formato áudio, as amostras foram randomizadas e julgadas por trinta sujeitos, que tiveram a tarefa de identificar os estilos. Os parâmetros acústicos que diferiram significativamente entre os estilos foram a Fo média, a Fo máxima, a variação de Fo e o tempo de fala. Os telespectadores foram capazes de identificar os diferentes estilos. Posteriormente as amostras foram separadas, por estilo, em três CDs, em formato áudio, e apresentadas por meio do Método de Comparação aos Pares a leigos, para que fossem julgadas em função de cada um dos estilos de emissão. Estes resultados foram submetidos à análise multidimensional (MDS-Multidimensional Scaling) para que fossem determinadas as dimensões em que se encontravam os diferentes estilos de emissão. Duas dimensões foram determinadas para cada estilo. No estilo descontraído, a primeira dimensão não teve parâmetro acústico significativamente correlacionado. Na segunda, sem distinção de gênero, foi significativo o número de semitons; para as vozes femininas a Fo mínima, a variação de Fo e o número de semitons; e para as vozes masculinas, nenhum parâmetro correlacionado foi significativo. No estilo neutro, a primeira dimensão, sem distinção de gênero, dois parâmetros foram significativamente correlacionados: Fo mínima e o número de semitons; para as vozes femininas, foi correlacionada significativamente a variação de Fo; e para as vozes masculinas, a Io máxima. Na dimensão dois, nenhum parâmetro foi correlacionado significativamente. No estilo sério, a primeira dimensão foi correlacionada significativamente com o parâmetro acústico tempo de fala, somente para as vozes masculinas. A dimensão dois apresentou os seguintes parâmetros correlacionados significativamente: sem considerar a distinção de gênero, a Fo média, Fo mínima e Io mínima; para as vozes femininas, a Io mínima; e para as vozes masculinas nenhum parâmetro acústico foi correlacionado significativamente. A partir desses resultados discutem-se possibilidades de intervenção com indivíduos que usam a comunicação profissionalmente. / Acoustic correlations were investigated and the identification of different emission styles in TV newscasts was rated in the following manner: neutral, serious and relaxed. Experienced presenters, from both genders, with constant appearances in network TV newscasts recorded a text with the same semantic content three times in the same emission styles. Based on this recording, the audio was separated in a CD in the wave format in order to perform the acoustic analysis of the sample assessing the acoustic parameters of frequency, intensity and duration of the emission through the Dr. Speech 4.0 software. In another CD, in the audio format, the samples were randomized and judged by 30 subjects with the task of identifying the styles. The acoustic parameters that differed significantly among the styles were the average Fo, maximum Fo, the Fo variation and the speech time. The spectators were capable of identifying the different styles. Later, the samples were separated by styles in three CDs in the audio format and presented by means of a Pair Comparison Method to lay individuals to be judged in function of each one of the emission styles. These data were submitted to a multidimensional analysis (MDS-Multidimensional Scaling) in order to determine the dimensions in which the different emission styles were. Two dimensions were determined for each style. In the relaxed style, the first dimension did not have a significantly correlated acoustic parameter. In the second one, without distinguishing the type, the number of semitones was significant; for the female voices, the minimum Fo, the Fo variation and the number of semitones; and for the male voices, there was no significant correlated pattern. In the neutral style, the first dimension, without distinguishing the type, two parameters were significantly correlated: minimum Fo and the number of semitones; for the female voices, the Fo variation had a significant correlation; and for the male voices, the maximum Io. In dimension two, no parameter presented a significant correlation. In the serious style, the first dimension was significantly correlated with the time of speech acoustic parameter, only for the male voices. Dimension two presented the following significantly correlated parameters: without considering the distinction of the type, average Fo, minimum Fo and minimum Io; for the female voices, the minimum Io; and for the male voices no acoustic parameter was significantly correlated. Based on these results, intervention possibilities with individuals that use communication professionally are discussed.
18

Nasalância para adultos de meia-idade e idosos falantes do português brasileiro /

Cardoso, Vanessa Moraes. January 2017 (has links)
Orientador: Viviane Cristina de Castro Marino / Banca: Célia Maria Giacheti / Banca: Ana Paula Fukushiro / Resumo: Valores de nasalância para indivíduos de meia-idade ou idosos não foram previamente determinados para falantes do Português Brasileiro (PB). O primeiro objetivo do estudo foi determinar valores de referência para falantes do PB de meia-idade e idosos, de ambos os gêneros. O segundo objetivo foi verificar variabilidade de teste e reteste imediato das medidas de nasalância para estas populações. O terceiro objetivo foi verificar possíveis efeitos de idade e gênero sobre os valores de nasalância ao longo da vida, levando em conta estímulos de fala controlados. Medidas de nasalância foram obtidas para 122 falantes do PB (62 de meia-idade e 60 idosos, ambos os gêneros) com fala normal para sete estímulos de fala (quatro orais, dois nasais e um oronasal) usando o equipamento Nasometer II 6400 (KayPentax, NJ, EUA). Os participantes realizaram duas leituras dos estímulos utilizando o capacete com a placa de separação de som do nasômetro. Valores médios de nasalância de cada estímulo foram determinados para cada leitura. A variabilidade do teste e reteste imediato foi analisada calculando a diferença absoluta entre a primeira e a segunda repetição para cada estímulo de fala dos falantes de meia-idade e idosos. Os valores de nasalância desses falantes foram combinados com dados de populações mais jovens obtidos por Marino et al. (2016a). Foram realizadas análises de variância de medidas repetidas para investigar as diferenças entre os estímulos por gênero e grupos etários. Os valores d... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Nasalance values for older populations were not previously determined for Brazilian Portuguese speakers (BP). The first goal of this study was to establish normative nasalance values for middle aged and elderly Brazilian Portuguese speakers. The second goal was to verify immediate test-retest variability on nasalance measurements for these populations. The third goal was to verify possible age and gender effects across the lifespan, considering distinct speech stimuli. Mean nasalance scores were obtained from 122 Brazilian Portuguese speakers (62 middle age and 60 elderly speakers, both genders) with normal speech for seven speech stimuli (four orals, two nasals and one oronasal) using the Nasometer II 6400 (KayPentax, N.J., USA). The participants read the stimuli twice while wearing the Nasometer's sound separator plate. Mean nasalance values for each stimulus were determined for each lecture. Test-retest variability was assessed by calculating the absolute difference between the middle aged and elderly participants' first and second repetition for each stimulus. The nasalance scores of the middle aged and elderly speakers were combined with data acquired from younger speakers (children, adolescent, young adult and adult) in Marino et al. (2016a). Repeated-measures two-way analysis of variance was used to investigate differences between the stimuli by gender and age groups. Nasalance values ranged from 12.48 to 16.64 (orals stimuli), 48.86-49.72 (nasals) and 27.98 (oronasal)... (Complete abstract click electronic access below) / Mestre
19

Reconhecimento de monossílabos em idosos: análise do nível de apresentação da fala / Monosyllabic words recognition in elderly: analysis of the speech presentation level

Santana, Bruna Antonini 26 February 2016 (has links)
A perda auditiva no idoso acarreta em dificuldade na percepção da fala. O teste comumente utilizado na logoaudiometria é a pesquisa do índice de reconhecimento de fala máximo (IR-Max) em uma única intensidade de apresentação da fala. Entretanto, o procedimento mais adequado seria a realização do teste em diversas intensidades, visto que o índice de acerto depende da intensidade da fala no momento do teste e está relacionado com o grau e configuração da perda auditiva. A imprecisão na obtenção do IR-Max poderá gerar uma hipótese diagnóstica errônea e o insucesso no processo de intervenção na perda auditiva. Objetivo: Verificar a interferência do nível de apresentação da fala, no teste de reconhecimento de fala, em idosos com perda auditiva sensorioneural com diferentes configurações audiométricas. Métodos: Participaram 64 idosos, 120 orelhas (61 do gênero feminino e 59 do gênero masculino), idade entre 60 e 88 anos, divididos em grupos: G1- composto por 23 orelhas com configuração horizontal, G2- 55 orelhas com configuração descendente, G3- 42 orelhas com configuração abrupta. Os critérios de inclusão foram: perda auditiva sensorioneural de grau leve a severo, não usuário de aparelho de amplificação sonora individual (AASI), ou com tempo de uso inferior a dois meses, e ausência de alterações cognitivas. Foram realizados os seguintes procedimentos: pesquisas do limiar de reconhecimento de fala (LRF), do índice de reconhecimento de fala (IRF) em diversas intensidades e do nível de máximo conforto (MCL) e desconforto (UCL) para a fala. Para tal, foram utilizadas listas com 11 monossílabos, para diminuir a duração do teste. A análise estatística foi composta pelo teste Análise de Variância (ANOVA) e teste de Tukey. Resultados: A configuração descendente foi a de maior ocorrência. Indivíduos com configuração horizontal apresentaram índice médio de acerto mais elevado de reconhecimento de fala. Ao considerar o total avaliado, 27,27% dos indivíduos com configuração horizontal revelaram o IR-Max no MCL, assim como 38,18% com configuração descendente e 26,19% com configuração abrupta. O IR-Max foi encontrado no UCL, em 40,90% dos indivíduos com configuração horizontal, 45,45% com configuração descendente e 28,20% com configuração abrupta. Respectivamente, o maior e o menor índice médio de acerto foram encontrados em: G1- 30 e 40 dBNS; G2- 50 e 10 dBNS; G3- 45 e 10 dBNS. Não há uma única intensidade de fala a ser utilizada em todos os tipos de configurações audiométricas, entretanto, os níveis de sensação que identificaram os maiores índices médios de acerto foram: G1- 20 a 30 dBNS, G2- 20 a 50 dBNS; G3- 45 dBNS. O MCL e o UCL-5 dB para a fala não foram eficazes para determinar o IR-Max. Conclusões: O nível de apresentação teve influência no desempenho no reconhecimento de fala para monossílabos em idosos com perda auditiva sensorioneural em todas as configurações audiométricas. A perda auditiva de grau moderado e a configuração audiométrica descendente foram mais frequentes nessa população, seguida da abrupta e horizontal. / Hearing loss in elderly causes difficulty in speech perception. The test commonly used in speech audiometry is the search for the maximum speech recognition score (PB-Max) in a single presentation intensity of speech. However, the most adequate procedure would be the test at multiple intensities considering that the correct level depends on the intensity of the speech at the moment of the test and is related to the degree and configuration of hearing loss. The imprecision in obtaining the PB-Max can produce an erroneous diagnostic hypothesis and failure in the intervention process in hearing loss. Purpose: To verify the interference of the level of speech presentation, through the speech recognition test, in elderly patients with sensorineural hearing loss with different audiometric configurations. Methods: Participants were 64 elderly, 120 ears (61 females and 59 males), ages ranging from 60 to 88, divided into three groups: G1- comprising 23 ears with flat configuration, G2- 55 ears with gradually sloping, G3- 42 ears with steeply sloping configuration. The criteria of inclusion of individuals were: sensorineural hearing loss from mild to severe degree, no hearing aid users, or period of use lower than two months, and absence of any cognitive impairment. The following procedures were performed: speech recognition threshold (SRT), word recognition scores at multiple intensities, most comfortable loudness level (MCL) and uncomfortable loudness level (UCL) using speech stimuli. For the procedure above, lists of 11 monosyllabic words were presented, in order for the test duration to be reduced. Statistical analysis was made by the test Analysis of Variance (ANOVA) and Tukey\'s test. Results: The gradually sloping configuration was the most common. Subjects with flat configuration showed higher correct mean level in speech recognition. Considering the total ears assessed, 27.27% of subjects with flat configuration revealed the PB-max in MCL, as well as, 38.18% with gradually sloping and 26.19% with steeply sloping configuration. The PB-max was found in the UCL, in 40.90% of the subjects with a flat configuration, 45.45% with gradually sloping configuration and 28.20% with steeply sloping configuration. Respectively, the highest and the lowest correct mean indexes were found: G1- 30 and 40 dB SL; G2- 50 and 10 dB SL; G3- 45 and 10 dB SL. There is not a single speech intensity to be used in all types of audiometric configurations, however, the sensation levels that identified the correct mean levels were found: G1 - 20-30 dB SL, G2 - 20-50 dB SL; G3 - 45 dB SL. The MCL and UCL-5 dB using speech stimuli, were not effective to determine the PB-Max. Conclusion: The presentation level influenced the performance in speech recognition for monosyllables in elderly patients with sensorineural hearing loss in all audiometric configurations. Moderate hearing loss and gradually sloping configuration were more frequent in this population, followed by steeply sloping and flat configuration.
20

Telemetria de resposta neural: repercussões dos fatores etiológicos e no reconhecimento de fala após o implante coclear / Neural response telemetry: repercussions of etiological factors and speech recognition after cochlear implant

Guedes, Mariana Cardoso 04 December 2007 (has links)
INTRODUÇÃO: O Potencial de Ação Composto Evocado Eletricamente(PACEE) é a medida da atividade sincrônica das fibras neurais eliciadas pelo implante coclear. O potencial é registrado diretamente da cóclea, utilizando os eletrodos como geradores do estímulo e gravadores da resposta, procedimento denominado Telemetria de Resposta Neural (TRN). A análise das características da resposta neural pode ser útil no conhecimento sobre a funcionalidade do nervo auditivo e das estruturas neurais sobreviventes. A presença do PACEE pode estar, portanto, relacionada ao resíduo auditivo e influenciar no desempenho para processar os estímulos de fala. OBJETIVO: Identificar os possíveis fatores associados à ausência do PACEE na condição intra-operatória e avaliar a repercussão da ausência de resposta neural no desempenho em testes de reconhecimento de fala após 06 meses de uso contínuo do implante coclear. MÉTODOS: Clínico longitudinal retrospectivo. Participaram do estudo todos os indivíduos operados entre 2003 e 2006 com o implante N24 e cujos exames evidenciaram inserção completa e ausência de alterações nas impedâncias (n = 97). A ausência da resposta neural foi estabelecida quando não se encontrava registro de onda com reprodutibilidade em nenhuma das séries de otimização em todos os eletrodos pesquisados. Os processadores de fala foram ativados com parâmetros sugeridos pelo fabricante e os níveis de corrente determinados pelo método psicoacústico. Os testes de percepção de fala foram realizados após seis meses de uso contínuo e sem leitura orofacial ou apoio de gestos. Os indivíduos foram divididos em grupos de acordo com a presença do PACEE: Grupo \"TRN presente\" e Grupo \"TRN ausente\". A média dos resultados nos testes de reconhecimento de fala foi comparada entre os dois grupos utilizandose o teste não paramétrico U de Mann-Whitney, Teste exato de Fisher e teste do Quiquadrado. RESULTADOS: No Grupo TNR ausente a prevalência de surdez por meningite foi de 48% e no Grupo TNR presente de 13.9% (p < 0,001). O risco relativo para um indivíduo com surdez pós-meningite não apresentar respostas neurais para o estímulo elétrico no intra-operatório é 3.1 vezes maior do que o de um indivíduo com surdez por outras causas. A amostra foi estratificada por etiologia. Os resultados mostraram forte associação entre a ausência do PACEE e piores resultados em testes de reconhecimento de fala. OS resultadoS dos indivíduos em que o potencial foi ausente foram significantemente menor que a média dos indivíduos com PACEE presente (p = 0,002), independente da etiologia da surdez. CONCLUSÃO: A ausência do PACEE em usuários do implante coclear sugere pobre capacidade de despolarização e de condução neural diante da estimulação elétrica. A etiologia de surdez por meningite esteve associada à ausência do potencial e à piores resultados nos testes de reconhecimento de fala. Independentemente deste fator, a presença do potencial no momento intra-operatório esteve associada ao melhor desempenho para processar estímulos de fala, sugerindo um bom prognóstico com o dispositivo. / INTRODUCTION: The Electrically Evoked Compound Action Potential (ECAP) is the register of synchronic activity o neural fibers stimulated by Cochlear Implant. The potential is registered directly from the cochlea using the electrodes as stimulus probe and recorder. This procedure is called Neural Response Telemetry (NRT). The analysis of ECAP can be useful to understand the auditory system function and the surviving neural population. The ECAP presence could be, though, related to auditory residual and influence the ability to process the speech stimulus. Objective: to identify the factors associated to the absent NRT responses and the consequence repercussions for speech recognition after six months of cochlear implant use. METHODS: longitudinal retrospective clinical study. Selection criteria: individual who received N24 cochlear implant model between 2003 and 2006 and presented exams showing complete insertion of electrode array and normal impedances results (n = 97). The NRT absent responses were established when there was no reproducible register in any optimization series of all electrodes searched. The implant speech processors were mapped according to the manufactures default. The current levels were determined by psychoacoustic method. The speech perception battery tests were performed after six months of continual use of device, without lipreading or gestures. The individuals were divided in two groups: Group \"NRT present\" and Group \"NRT absent\". The average of speech perception tests results were compared between groups using the non-parametric Mann-Whitney U test, Exact Fisher\'s test and Chi-square test. RESULTS: In NRT absent group the prevalence of post meningitis hearing loss was 48% and in NRT present group of 13.9% (p < 0.001). The results showed strong association between the absence of ECAP and lower performance in speech recognition sentence test. In these results, the average of subjects whose potential were absent was significantly lower than the ones with ECAP present by intraoperative NRT, regardless the hearing loss etiology (p = 0.002). CONCLUSION: The ECAP absence in cochlear implant users suggests poor neural conduction under electrical stimulus. The post meningitis hearing loss was associated to the absence of potential and poor performance in the speech recognition tests. However, the presence of reproducible ECAP waves was associated to a better performance in processing speech stimulus and suggests a good prognosis with the cochlear implant device.

Page generated in 0.4731 seconds