• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 142
  • 142
  • 122
  • 121
  • 54
  • 53
  • 40
  • 35
  • 35
  • 32
  • 30
  • 29
  • 28
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Investigação da eficácia da teleconsulta na programação do implante coclear / Investigation of effectiveness of teleconsultation in cochlear implant programming

Ademir Antonio Comerlatto Junior 23 March 2016 (has links)
A demanda crescente de usuários de implante coclear (IC) e a distribuição irregular de profissionais especializados no país, tornam necessário o deslocamento de pacientes por longas distâncias para os atendimentos, com consequente aumento dos custos diretos e indiretos do tratamento. A teleconsulta pode ser vista como uma alternativa em potencial para o acesso desta população a estes serviços. O presente ensaio clínico, randomizado, controlado, avaliou a eficácia da teleconsulta síncrona na programação dos sistemas de IC em usuários acompanhados em um Programa de Implante Coclear credenciado pelo Sistema Único de Saúde. Participaram do estudo 79 indivíduos com idades entre nove e 68 anos (média de 21,6), 41 do sexo masculino e 38 do sexo feminino, usuários de IC por um período de 0,58 a 24,75 anos. Estes indivíduos foram divididos em dois grupos, de acordo com o modo de programação do IC: controle (n=40), que realizou o procedimento face a face e experimental (n=39) que realizou a teleconsulta síncrona. Treze fonoaudiólogos sem experiência na programação do dispositivo atuaram como facilitadores das teleconsultas. Os procedimentos de programação do IC englobaram a telemetria de impedância, definição dos níveis de estimulação elétrica, varredura e balanceamento dos eletrodos e ajuste fino da programação. Como medidas de avaliação de resultados foram utilizados o tempo dispendido na consulta, a audiometria em campo livre, o percentual de reconhecimento de sentenças no silêncio e no ruído, o limiar de reconhecimento de sentenças no silêncio e ruído (HINT-Brasil), a avaliação da satisfação com a consulta (escala MISS-21) e de aspectos pertinentes à teleconsulta. Os facilitadores responderam as questões abertas referentes à suas impressões dos atendimentos. Os dados foram analisados por meio de estatística inferencial (testes t de Student, Wilcoxon, Mann-Whitney e correlação de Spearman). Os resultados mostraram que após a programação do IC, em média, os participantes apresentaram limiares audiométricos abaixo de 30 dB NA. O reconhecimento da fala pós atendimento, respectivamente para os grupos experimental e controle, foram de 81,3% e 83,8% (silêncio) e 57,9% e 58,1% (ruído). No HINT-Brasil os resultados foram, respectivamente, para os grupos experimental e controle 61,4 dB NA e 61,8 dB NA (silêncio) e relação S/R de 9,5 dB NA e 10,4 dB NA (ruído). Os participantes estiveram satisfeitos com a consulta. Não houve diferença estatisticamente significativa entre os grupos em nenhuma das medidas de resultado. Todos os participantes relataram que teleconsulta pode ser vista como uma alternativa viável ao atendimento face a face e sua aplicação clínica facilitaria a rotina de pacientes usuários de IC. Os facilitadores destacaram a sua importância para o aprendizado e como ferramenta de formação continuada. A teleconsulta síncrona foi eficaz na programação dos sistemas de IC e amplamente aceita pelos usuários e profissionais. / The growing number of cochlear implant (CI) users and the uneven distribution of specialized professionals in the country makes necessary patients traveling over long distances to receive care, with consequent increase in direct and indirect costs of treatment. The telehealth can be viewed as an alternative for this population to access such services. This clinical randomized, controlled clinical trial evaluated the efficacy of synchronous teleconsultation in the programming of CI systems in a Cochlear Implant Program accredited by the National Health System in Brazil. Participate in this study 79 subjects aged between nine and 68 years (average 21.6), 41 males and 38 females, CI users for a period from 0.58 to 24.75 years. The participants were divided into two groups, according to the nature of consultation: control group (n = 40), who performed the CI programming face-to-face and experimental group (n = 39) who performed the CI programming through the synchronous teleconsultation. Thirteen audiologists without experience in CI programming acted as facilitators of teleconsultation. The CI programming procedures encompassed the impedance telemetry, setting of electrical stimulation levels, sweeping and balancing of the electrodes and programming evaluation in live speech mode. The outcome measures were the time spent in consultation, free field audiometry, the percentage of sentence recognition in quiet and in noise, the sentence recognition threshold in silence and noise (HINT-Brazil), satisfaction with the consultation (MISS-21 scale) and aspects related to teleconsultation. The facilitators responded open questions regarding their impressions of the teleconsultations. Data were analyzed using inferential statistics (Student t test, Wilcoxon, Mann-Whitney and Spearman correlation). The results showed that after CI programming, on average, the participants had audiometric thresholds below 30 dB HL. The speech perception for the experimental and control groups post CI programming were respectively, 81.3% and 83.8% (in silence) and 57.9% and 58.1% (in noise). In HINT-Brazil the results were, respectively, for the experimental and control groups 61.4 and 61.8 dB (silence) and S/N ratio of 9.5 dB and 10.4 dB (in noise). Participants were satisfied with the teleconsultation. There were no statistically significant difference between the groups in any of the outcome measures. All participants reported that teleconsultation could be a viable alternative to facilitate CI users follow up routine. Facilitators emphasized the importance of teleconsultation for learning and for continuing education. The teleconsultation was effective in programming the CI systems and accepted by users and professionals.
132

O efeito da estimulação top-down e bottom-up no potencial evocado auditivo de tronco encefálico com estímulo complexo / The effect of top-down and bottom-up stimulation on auditory brainstem response to complex sounds

Leite, Libia Camargo Ribeiro 25 April 2016 (has links)
Introdução: Crianças com transtorno fonológico (TF) apresentam dificuldade na percepção de fala, em processar estímulos acústicos quando apresentados de forma rápida e em sequência. A percepção dos sons complexos da fala, dependem da integridade no processo de codificação analisado pelo Sistema Nervoso Auditivo. Por meio do Potencial Evocado Auditivo de Tronco Encefálico com estímulo complexo (PEATEc) é possível investigar a representação neural dos sons em níveis corticais e obter informações diretas sobre como a estrutura do som da sílaba falada é codificada no sistema auditivo. Porém, acredita-se que esse potencial sofre interferências tanto de processos bottom-up quanto top-down, o que não se sabe é quanto e como cada um desses processos modifica as respostas do PEATEc. Uma das formas de investigar a real influência dos aspectos top-down e bottom-up nos resultados do PEATEc é estimulando separadamente esses dois processos por meio do treinamento auditivo e da terapia fonoaudiológica. Objetivo: Verificar o impacto da estimulação sensorial (processamento bottom-up) e cognitiva (processamento top-down), separadamente, nos diferentes domínios da resposta eletrofisiológica do PEATEc. Método: Participaram deste estudo 11 crianças diagnosticadas com TF, com idades entre 7 e 10:11, submetidas a avaliação comportamental e eletrofisiológica e então dividas nos grupos Bottom-up (B-U) (N=6) e Top-down T-D (N=5). A estimulação bottom-up foi voltada ao treinamento das habilidades sensoriais, através de softwares de computador. A estimulação top-down foi realizada por meio de tarefas para estimular as habilidades cognitiva por meio do Programa de Estimulação Fonoaudiológica (PEF). Ambas as estimulações foram aplicadas uma vez por semana, num período de aproximadamente 45 minutos por 12 semanas. Resultados: O grupo B-U apresentou melhoras em relação aos domínios onset e harmônicos e no valor da pontuação do escore após ser submetido à estimulação bottom-up. Por sua vez, após serem submetidos à estimulação top-down, o grupo T-D apresentou melhoras em relação aos domínios onset, espectro-temporal, fronteiras do envelope e harmônicos e para os valores da pontuação do escore. Conclusão: Diante dos resultados obtidos neste estudo, foi possível observar que a estimulação sensorial (processamento bottom-up) e a estimulação cognitiva (processamento top-down) mostraram impactar de forma diferente a resposta eletrofisiológica do PEATEc / Introduction: Children with speech sound disorder present difficulties in speech perception specially regarding the processing of acoustic stimuli when they occur rapidly and sequentially. The perception of complex sounds of speech depends on the integrity of the codification process analyzed by the auditory system. Through the Auditory Brainstem Response to complex sounds (cABR) it is possible to investigate the neural representation of sounds in cortical levels to obtain direct information about how the sound structure of the stressed syllable is codified in the auditory system. However, it is believed that bottom-up and top-down processes interfere in the cABR, though the level of intensity and the way through which they can change the response of the cABR is still unkown. One of the methods for investigating the actual influences of the bottom-up and top-down processes in cABR responses is by stimulating separately those two processes by means of auditory training and speech therapy. Objective: Verify the impact of both sensory stimulation (bottom-up processing) and cognitive stimulation (top-down processing) separately, in the different domains of the cABR electrophysiological response. Method: The participants of the study were 11 children of 7 to 10:11 year-old diagnosed with speech sound disorder, who underwent behavioral and electrophysiological assessment and were divided in the following groups: Bottom-up (B-U) (N=6) and Top-down (T-D) (N-5). The bottom-up stimulation focused on sensorial skills by using computer softwares. Top-down stimulation was prosecuted by using tasks to stimulate cognitive skills through the Speech Stimulation Program. Both stimuli were applied once a week for 45 minutes, in a period of 12 weeks. Results: The B-U group showed improvement in relation to onset and harmonic domains, and in relation to the score punctuation values after being subjected to bottom-up stimulation. On the other hand, the T-D group, after being subjected to top-down stimulation, showed improvement in relation to the onset, time domain spectrum, envelope boundaries and harmonics, and to the score punctuation values. Conclusions: According to the results of this study, it was possible to conclude that sensorial stimulation (bottom-up processing) and cognitive stimulation (top-down processing) showed different impacts on the cABR electrophysiological response
133

Produção e percepção da fricativa interdental surda por aprendizes brasileiros de língua inglesa

Peleias, Fabiola D'Agostini 06 November 2009 (has links)
Made available in DSpace on 2016-04-28T18:24:13Z (GMT). No. of bitstreams: 1 Fabiola Dagostini Peleias.pdf: 3457328 bytes, checksum: 7dd5e2d586af21d038754992b5d71372 (MD5) Previous issue date: 2009-11-06 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work is part of the sound acquisition area in second language (L2), specifically in English, and it aimed to investigate whether there was a relationship between production and perception of the voiceless interdental fricative pronunciation [θ] or not in a group of Brazilian native speakers (BNS), based on acoustic and phonetic analysis. It was stated that there is such a relationship on account of the BNS in the sample. According to the literature, Brazilian learners of English tend to produce the voiceless interdental fricative [θ] as [s], [f] and [t] ((LIEFF & NUNES, 1993). This is because they consider such sound to be similar to [s], [f] and [t], and as stated by Flege (1999) and Meador, Flege and MacKay (2000), similar sounds of L1 (native language, in this case, Brazilian Portuguese - BP) and L2 may cause difficulties for the learner. Three studies have been made: an analysis of the production of the 3 BNS as well as of the AMS (American Native speaker) concerning the sound [θ]; an analysis of the perception of the sound [θ] by the 3 BNS and, finally, an evaluation of the 3 BNS productions of the sound [θ] by 31 American Native judges. The results of the three analyses have been crossed, and it can be posed that they conform to the literature about the link between production and perception and the assimilation of sounds from L2 to L1. Moreover, with such results, it was possible to achieve the goal of this work. It was verified that, regarding the perception analysis, the three BNS tend to perceive the sound [θ] as [θ] or [t]. Regarding the production analysis, one of the BNS approached the ANS. Therefore, it can be stated that there is a relationship between this BNS perception and production. The two remaining BNS did not approach the ANS. Most of the time, those speakers perceived the sound [θ] as [t], and the same happened with their productions of the sound [θ]. Taking into account those figures, it can be stated that there is a relationship among their production and perception, even if they have not perceived the sound [θ] as it should have been done. The perception and production analyses results were compared with the evaluation of the 31 judges, and the same can be said concerning all BNS: one of the BNS approached the ANS concerning the sound [θ], and the two remaining ones did not approach the ANS. To sum up, it was observed that, in this particular sample, there is a relationship between their production and perception, and that two out of the three BNS assimilated the sound [θ] as [t] / Este trabalho situa-se na área de aquisição de sons de L2 (segunda língua), mais especificamente língua inglesa, e seu objetivo foi investigar se existe uma relação entre a produção e a percepção da pronúncia da fricativa interdental surda [θ] em um grupo de sujeitos nativos brasileiros, a partir da análise fonético-acústica. Defendia-se que há uma relação entre a percepção e a produção da pronúncia da fricativa interdental surda pelos sujeitos nativos brasileiros da amostra. Segundo a literatura, aprendizes brasileiros de inglês tendem a produzir a fricativa interdental surda da língua inglesa [θ] como [s], [f] e [t] (LIEFF e NUNES, 1993). Isso porque consideram que esse som é similar aos citados e, de acordo com Flege (1999) e Meador, Flege e MacKay (2000), sons similares de L1 (língua materna Português Brasileiro - PB)e L2 causam dificuldades para o aprendiz. Foram feitos três estudos: uma análise das produções dos 3 SNB (sujeitos nativos do PB) e do SNA (sujeito nativo americano) envolvendo a [θ]; uma análise de percepção do [θ] pelos 3 SNB e uma avaliação, por juízes nativo-americanos, das produções dos 3 SNB e do SNA envolvendo o [θ]. Os resultados dos estudos foram cruzados, e constatou-se que estão em consonância com a literatura sobre o vínculo entre produção e percepção e assimilação de sons em L2 para a L1, atingiram o objetivo e validaram a hipótese defendida. Os 3 SNB, no teste de percepção, tendem a perceber o som [θ], em sua maioria, como [θ] ou como [t]. No teste de produção, a SNB1 aproximou-se do SNA; para esse sujeito, há relação entre sua percepção e sua produção. Os SNB2 e SNB3 se distanciaram do SNA. Em sua maioria, perceberam os estímulos como plosiva alveolar surda [t], comportamento que também se refletiu em sua produção. Portanto, pode-se afirmar que há relação entre produção-percepção, mesmo não tendo percebido e produzido o som [θ], em sua maioria, de maneira correta. Os testes foram comparados às avaliações dos juízes norte-americanos, e o mesmo pode ser afirmado para todos os sujeitos: os estímulos do SNB1, em sua maioria, foram avaliados como fricativa interdental surda [θ], do SNB2 como plosiva alveolar surda [t] e do SNB3 também como plosiva alveolar surda [t]. Observou-se, nesta amostra, que houve a relação entre produção e percepção e que 2 entre 3 dos SNB assimilaram [θ] como [t]
134

Avaliação da frequência fundamental em laringes humanas excisadas com diferentes extensões de sinéquia glótica anterior / Fundamental frequency in excised human larynges after the formation of anterior glottic webs of varying extent

Pinheiro, Thaís Gonçalves 25 May 2016 (has links)
INTRODUÇÃO: Os resultados do aumento da frequência fundamental após diminuição do comprimento da porção vibratória das pregas vocais pela realização de sinéquia na região anterior da glote são variáveis, e não é estabelecida a extensão ideal de tal sinéquia nas técnicas cirúrgicas para aumentar a frequência vocal. Comparou-se neste estudo a elevação da frequência fundamental do som produzido por laringes humanas excisadas de cadáveres após realização de diferentes extensões de sinéquia glótica anterior, correspondentes a ¼ (25%), 1/3 (33%) e ½ (50%) do comprimento da prega vocal. Além disso, verificou-se a correlação entre as frequências fundamentais anterior e posteriores aos experimentos com tais diferentes extensões de sinéquia glótica anterior para formular modelos matemáticos que estimem a frequência fundamental obtida após o procedimento. Os padrões de vibração das pregas vocais foram avaliados qualitativamente por videolaringoscopia e videoquimografia digital com câmera de alta velocidade. MÉTODOS: Realizou-se estudo experimental com 21 laringes humanas excisadas de cadáveres masculinos adultos. O som glótico foi artificialmente produzido com a colocação de ar comprimido pela traqueia, passando pelas pregas vocais. A frequência fundamental e os parâmetros da videoquimografia digital foram obtidos previamente (controle) e após realização de pontos que mimetizaram uma sinéquia glótica anterior de ¼, 1/3 e ½ do comprimento das pregas vocais em todas as laringes, simulando uma das técnicas cirúrgicas para aumento da frequência vocal, a glotoplastia de Wendler. RESULTADOS: A frequência fundamental média foi distinta entre as diferentes extensões de sinéquia glótica anterior (P < 0,001), e observou-se aumento progressivo, significativo a cada ampliação da extensão da sinéquia na glote (P < 0,05), tanto em hertz quanto em semitons. Os modelos de regressão que estimam a frequência fundamental após os procedimentos mostraram melhor coeficiente de determinação (r2) para extensões menores de sinéquia. Não se verificou aperiodicidade das vibrações em nenhum experimento, nem se constatou padrão de mudança de fechamento glótico ou de simetrias de fase e amplitude. CONCLUSÕES: A frequência fundamental do som aumentou com diferença significativa a cada ampliação da extensão da sinéquia anterior na glote, sem alterações significativas nos parâmetros qualitativos da onda mucosa. Esses resultados sugerem que a medida da extensão da sinéquia glótica é relevante para o resultado final na elevação da frequência fundamental, e os dados apresentados podem ser uma referência inicial para o prognóstico do resultado cirúrgico / INTRODUCTION: After anterior glottic web formation to decrease the length of the vibrating portion of the vocal folds, the degree of increase in fundamental frequency is variable. The ideal extent of such a web in surgical approaches aimed at raising the vocal pitch has not been established. This study compared the increase in the fundamental frequency of sound produced by excised human larynges after the formation of anterior glottic webs of varying extents (25%, 33%, and 50% of the length the vocal fold). In addition, the correlation between the fundamental frequencies before and after the experiments with the various extents of anterior glottic web formation was verified in order to create mathematical models designed to estimate the change in fundamental frequency obtained after the procedure. The vibration patterns of the vocal folds were evaluated qualitatively by laryngoscopy and by kymography with a highspeed digital camera. METHOD: We conducted an experimental study on 21 normal larynges excised from adult male human cadavers. Laryngeal vibration was artificially produced and was recorded by high speed videoendoscopy and digital kymography for analysis. The fundamental frequency and digital videokymography parameters were obtained before (as a control) and after the formation of anterior glottic webs occupying 25%, 33%, and 50% of the vocal folds, simulating a surgical technique to increase the vocal frequency, Wendler glottoplasty. RESULTS: The mean fundamental frequency differed among the various extents of anterior glottic web formation (P < 0.001), and there were significant increases from one extent to the next (P < 0.05), in hertz as well as in semitones. Regression models to estimate post-procedure fundamental frequency showed better coefficients of determination (r2) for smaller web extents. There was no aperiodic vibration in any of the experiments. The changes in glottal closure/phase and amplitude symmetry did not follow any particular pattern. CONCLUSIONS: The fundamental frequency increased significantly at each increase in the extent of the anterior glottic web, without significant changes in the qualitative parameters of vocal fold vibration. These results suggest that the extent of the glottic web influences the final result, in terms of the magnitude of the increase in the fundamental frequency, and the data presented here could serve as an initial reference for the postoperative prognosis
135

Contribuição do avanço tecnológico do processador de fala para usuários de implante coclear Nucleus 22® / Contribution of the technological advance of the speech processor to patients with Nucleus 22®

Magalhães, Ana Tereza de Matos 03 October 2013 (has links)
Objetivo: Identificar as contribuições tecnológicas do processador de fala Freedom® para pacientes implantados com Nucleus 22® e a satisfação dos usuários com a nova tecnologia. Entre os novos recursos disponíveis, foram analisados o efeito da tabela de alocação de frequências, o T-SPL e C-SPL e o ajuste de pré-processamento do som (ADRO®). Material: Este estudo foi prospectivo e exploratório. Foram incluídos adolescentes e adultos implantados com Nucleus 22® no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, usuários efetivos do processador de fala Spectra®, com alguma percepção de frases em contexto fechado e sem experiência anterior com a nova tecnologia. Foram selecionados 17 pacientes, entre as idades de 15 e 82 anos, e implantados há mais de oito anos. Para determinar a contribuição do Freedom®, os limiares auditivos e os testes de percepção de fala foram realizados com o último mapa utilizado com o Spectra® e comparados os mapas criados com o Freedom®. Para identificar o efeito da tabela de alocação de frequências, ambos os mapas convertidos (mesma tabela) e atualizados (tabela nova) foram programados. A tabela escolhida foi mantida, e foram realizados três mapas com diferentes parâmetros: o programa 1 (P1) com T-SPL de 30 dB e do C-SPL de 70 dB, programa 2 (P2) com T-SPL de 25 dB e do C-SPL de 65 dB, e o programa 3 (P3) com ADRO®. A ordem de apresentação dos mapas e dos testes foi randomizada. Para avaliar a satisfação com seus dispositivos auditivos foram utilizados os questionários SADL e APHAB após um mês e um ano de uso do Freedom®. Resultados: A contribuição do processador de fala Freedom® para pacientes usuários do Nucleus 22® foi estatisticamente superior em comparação com o Spectra® em todos os testes de percepção da fala e em todos os limiares audiométricos, tanto individualmente quanto em média, com exceção de 8000 Hz. Em relação à escolha da tabela de frequência, 64,7% dos pacientes (n=11) mantiveram o mapa com a tabela de frequências do Spectra®. Comparando os mapas com diferentes T-SPL e C-SPL, houve diferença estatística tanto nos limiares audiométricos de 500, 1000, 1500 e 2000 Hz quanto na média. Não houve diferença estatística entre os testes de fala com ou sem o uso do ADRO®. Os questionários de satisfação mostraram uma melhora estatisticamente significativa, apenas na subescala que avalia o desempenho em ambiente ruidoso e uso do telefone. Conclusão: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®. A maioria manteve a tabela de frequência original. As mudanças nos parâmetros de T-SPL e C-SPL mostraram uma melhora dos limiares audiométricos nas frequências principais da fala. As diferenças significantes foram sutis nos questionários de satisfação, demonstrando que os pacientes já estavam adaptados e satisfeitos com o implante coclear / Objective: To identify the technological contributions of the Freedom® speech processor to the patients implanted with Nucleus 22® and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL and the pre-processing gain adjustments (ADRO®). Methods: This study was prospective and exploratory. It included teenage and adult patients implanted with Nucleus 22® who effectively used the implant with no previous experience with the new technology and had at least some speech recognition on a closed set with the Spectra® processor. Seventeen patients met the inclusion criteria, ranging in age from 15 to 82 years and deployed for over 8 years. To determine the contribution of the Freedom®, thresholds and speech perception tests were performed with the last map used with the Spectra® and the maps created for Freedom®. To identify the effect of the frequency allocation table, both converted (same table) and upgraded (new table) maps were programmed. The table selected is maintained, and maps were performed with three different parameters: the first program (P1) was programmed with 30 dB T-SPL and 70 dB C-SPL; the second program (P2) with was programmed with 25 dB T-SPL and 65 dB C-SPL; and the program 3 (P3) with ADRO®. The order of presentation of the maps and the testing was randomized. To assess satisfaction were used SADL and APHAB after one moth and one year of using the Freedom®. Results: The contribution of the Freedom® speech processor to patients with the Nucleus 22® was statistically superior compared to the Spectra® in all tests of speech perception and in all audiometric thresholds, both individually and on average, except for 8000 Hz. Regarding the choice of a frequency allocation table, 64.7% of patients (n=11) maintained the same map that had been used with the Spectra® processor. The sound field threshold was statistically significant at 500, 1000, 1500 and 2000 Hz with 25 dB T-SPL/ 65 dB C-SPL. The patients\' satisfaction there was a statistically significant improvement, only in the sub-scale of speech in noise abilities and telephone use. Conclusions: The Freedom® technology improved the performance of patients with the Nucleus 22®. Most of the patients retained the original frequency table. The changes in the parameters of T-SPL and C-SPL showed an improvement in the audiometric thresholds for the main frequencies of speech. Significant differences were subtle in questionnaires of satisfaction, demonstrating that patients were already adapted and satisfied with the cochlear implant
136

Avaliação da frequência fundamental em laringes humanas excisadas com diferentes extensões de sinéquia glótica anterior / Fundamental frequency in excised human larynges after the formation of anterior glottic webs of varying extent

Thaís Gonçalves Pinheiro 25 May 2016 (has links)
INTRODUÇÃO: Os resultados do aumento da frequência fundamental após diminuição do comprimento da porção vibratória das pregas vocais pela realização de sinéquia na região anterior da glote são variáveis, e não é estabelecida a extensão ideal de tal sinéquia nas técnicas cirúrgicas para aumentar a frequência vocal. Comparou-se neste estudo a elevação da frequência fundamental do som produzido por laringes humanas excisadas de cadáveres após realização de diferentes extensões de sinéquia glótica anterior, correspondentes a ¼ (25%), 1/3 (33%) e ½ (50%) do comprimento da prega vocal. Além disso, verificou-se a correlação entre as frequências fundamentais anterior e posteriores aos experimentos com tais diferentes extensões de sinéquia glótica anterior para formular modelos matemáticos que estimem a frequência fundamental obtida após o procedimento. Os padrões de vibração das pregas vocais foram avaliados qualitativamente por videolaringoscopia e videoquimografia digital com câmera de alta velocidade. MÉTODOS: Realizou-se estudo experimental com 21 laringes humanas excisadas de cadáveres masculinos adultos. O som glótico foi artificialmente produzido com a colocação de ar comprimido pela traqueia, passando pelas pregas vocais. A frequência fundamental e os parâmetros da videoquimografia digital foram obtidos previamente (controle) e após realização de pontos que mimetizaram uma sinéquia glótica anterior de ¼, 1/3 e ½ do comprimento das pregas vocais em todas as laringes, simulando uma das técnicas cirúrgicas para aumento da frequência vocal, a glotoplastia de Wendler. RESULTADOS: A frequência fundamental média foi distinta entre as diferentes extensões de sinéquia glótica anterior (P < 0,001), e observou-se aumento progressivo, significativo a cada ampliação da extensão da sinéquia na glote (P < 0,05), tanto em hertz quanto em semitons. Os modelos de regressão que estimam a frequência fundamental após os procedimentos mostraram melhor coeficiente de determinação (r2) para extensões menores de sinéquia. Não se verificou aperiodicidade das vibrações em nenhum experimento, nem se constatou padrão de mudança de fechamento glótico ou de simetrias de fase e amplitude. CONCLUSÕES: A frequência fundamental do som aumentou com diferença significativa a cada ampliação da extensão da sinéquia anterior na glote, sem alterações significativas nos parâmetros qualitativos da onda mucosa. Esses resultados sugerem que a medida da extensão da sinéquia glótica é relevante para o resultado final na elevação da frequência fundamental, e os dados apresentados podem ser uma referência inicial para o prognóstico do resultado cirúrgico / INTRODUCTION: After anterior glottic web formation to decrease the length of the vibrating portion of the vocal folds, the degree of increase in fundamental frequency is variable. The ideal extent of such a web in surgical approaches aimed at raising the vocal pitch has not been established. This study compared the increase in the fundamental frequency of sound produced by excised human larynges after the formation of anterior glottic webs of varying extents (25%, 33%, and 50% of the length the vocal fold). In addition, the correlation between the fundamental frequencies before and after the experiments with the various extents of anterior glottic web formation was verified in order to create mathematical models designed to estimate the change in fundamental frequency obtained after the procedure. The vibration patterns of the vocal folds were evaluated qualitatively by laryngoscopy and by kymography with a highspeed digital camera. METHOD: We conducted an experimental study on 21 normal larynges excised from adult male human cadavers. Laryngeal vibration was artificially produced and was recorded by high speed videoendoscopy and digital kymography for analysis. The fundamental frequency and digital videokymography parameters were obtained before (as a control) and after the formation of anterior glottic webs occupying 25%, 33%, and 50% of the vocal folds, simulating a surgical technique to increase the vocal frequency, Wendler glottoplasty. RESULTS: The mean fundamental frequency differed among the various extents of anterior glottic web formation (P < 0.001), and there were significant increases from one extent to the next (P < 0.05), in hertz as well as in semitones. Regression models to estimate post-procedure fundamental frequency showed better coefficients of determination (r2) for smaller web extents. There was no aperiodic vibration in any of the experiments. The changes in glottal closure/phase and amplitude symmetry did not follow any particular pattern. CONCLUSIONS: The fundamental frequency increased significantly at each increase in the extent of the anterior glottic web, without significant changes in the qualitative parameters of vocal fold vibration. These results suggest that the extent of the glottic web influences the final result, in terms of the magnitude of the increase in the fundamental frequency, and the data presented here could serve as an initial reference for the postoperative prognosis
137

Percepção e produção de sons de fala em uma criança com deficiência auditiva em terapia fonoaudiológica / Perception and production of speech in a hearing impaired child during therapy

Pessoa, Aline Neves 22 February 2008 (has links)
Made available in DSpace on 2016-04-27T18:12:28Z (GMT). No. of bitstreams: 1 Aline Neves Pessoa.pdf: 4984178 bytes, checksum: d99c1ef907dc4b911ae372a955638bc2 (MD5) Previous issue date: 2008-02-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Introduction: Very few studies discuss speech development in hearing impaired children in the first years of life due to methodological difficulties and the number of variables involved. Acoustic inspection of articulatory adjustments and attempts to imitate a model made by the infant in different contexts can be a method to comprehend the manner in which first oral motor skills occur. The understanding of this process can provide strategies concerning intervention programs for infants in stages when motor gestures of speech are being acquired. The objective of this longitudinal study was to describe samples of speech production from a hearing impaired child, extracted from interactive situations in auditory rehabilitation, seeking to discuss phonetic development in different therapeutic contexts. The study also sets out to characterize and reflect upon the effects of therapist mediation in situations of longitudinal and transversal samples, particularly situations of spontaneous production and in immediate repetition facilitated by auditory feedback. Method: A case study design was used. The subject was 2y 11mo in the beginning of the study, and 3y 6mo at the last recording. I is a girl, with severe progressive bilateral sensory neural hearing loss with descending audiometric configuration. She had been using hearing aids since six months of age, and FM system since 3y 1mo of age. The effect of the use of FM system was also analyzed. Audio recordings of the child s therapy session were obtained and samples were selected based on auditory perception. These fragments were analyzed using a qualitative acoustic inspection. The PRAAT 4.0 software used for speech synthesis and analysis was utilized for acoustic inspection. Results and discussion: The data allows for discussion of the child s possibilities regarding adjustments of vocal source and filters in relation to her auditory feed back possibilities. Segmental and supra-segmental aspects were studied, as was modulation, tonal spectrum, fundamental frequency, and formants. The processes of substitution, omission, distortion, and odd solutions for articulatory adjustments, such as sudden vocal attack and nasalization, or systematic substitution of fricative for plosive phonemes were evident, especially spontaneous speech. Therapeutic strategies aimed at the multiplication of the possibilities of auditory feedback moments in which the child had greater possibility for adjustment in the form of its vocabulary we noticed that the articulators and source began to adjust in the direction of the target, and the articulatory gesture became more consistent. Also, after using the FM system in addition to hearing aids for five months, fricative phonemes, flaps, and other consonants that were previously less audible in the child s daily life became more frequent since she was able to perceive the form and meaning of speech in a more stable and accessible manner. Conclusions: Clinical strategies based on the need to more audibility aiming at speech development occur in the context of dialogues with the therapist. Multiple opportunities for auditory feedback are directed towards oral motor abilities in the acquisition of different phonemes. Therefore, acoustic inspection allowed for the establishment of relationship with auditory perception, enhancing the understanding of phonetic and phonological features, as well as symbolic and discursive aspects of oral language. Implications of the findings for clinical management are discussed. Acoustic inspection and its relation to auditory feed back seems to be a powerful method for understanding on the phonetic development in young children contributing to the development of therapeutic strategies / Introdução: Poucos estudos discutem a fase inicial do desenvolvimento de fala em sujeitos deficientes auditivos devido às dificuldades metodológicas e ao número de variáveis envolvidas. A inspeção acústica diante dos ajustes realizados na produção de fala em diferentes contextos propiciados pelo enquadre terapêutico pode ser uma possibilidade para compreendermos as primeiras hipóteses acerca das habilidades motoras de fala, a partir das condições sensoriais auditivas. A compreensão deste processo traz conhecimento acerca do desenvolvimento de linguagem de deficientes auditivos, repercutindo nas formulações de estratégias de intervenção/tratamento nessas crianças. Objetivo: Descrever amostras de produção de fala em uma criança com deficiência auditiva; caracterizar e refletir sobre a produção de fala em situações do enquadre terapêutico visando discutir os ajustes fonoarticulatórios na produção de fala dos sons do português brasileiro (PB), através da interpretação dos dados acústicos em relação à audição residual. Material e método: Trata-se de um estudo de caso, sendo o sujeito do sexo feminino, no início da pesquisa com 2a11m, e no término, com 3a6m de idade, portador de deficiência auditiva neurossensorial progressiva de grau profundo bilateral. A criança usava aparelhos de amplificação sonora individual (AASIs) desde 6 meses de idade e Sistema de Freqüência Modulada (Sistema FM) desde 3a1m de idade. Gravações de áudio da produção de fala em sessão terapêutica de abordagem verbaloral e os recortes transversais e longitudinais de sons de fala em diferentes contextos permitiram a inspeção acústica (através do software Praat v 4.0). Resultados e Discussão: Os dados trouxeram discussões acerca das hipóteses e dos ajustes de fonte e filtro realizados pela criança a partir da sua condição de utilização da audição residual. Aspectos segmentais, supra-segmentais e de qualidade vocal puderam ser estudados, tais como modulação, gama tonal, freqüência fundamental e formantes. Processos de ajustes, caracterizados também por substituições, omissões e distorções, e recursos, como o de golpe de glote e nasalização, dentre mudanças sistemáticas no modo de produção de consoantes (plosão no lugar de fricção) caracterizaram algumas das produções de fala da criança nos primeiros momentos da análise; as instabilidades e imprecisões articulatórias foram mais acentuadas nos momentos de emissão espontânea do que nos momentos por repetição imediata. A partir das estratégias terapêuticas, compostas por multiplicação de possibilidades de feedback auditivo, notou-se que os articuladores e fonte começaram a se ajustar mais precisamente em direção ao alvo, e assim, o gesto articulatório se mostrava menos frágil. O Sistema FM acoplado aos AASIs também ofereceu melhores condições de multiplicação de evidências sensoriais para a percepção auditiva; no decorrer dos meses, percebemos que as hipóteses e ajustes para formar engramas dos fones fricativos, laterais flapes, dentre outros começaram a se constituir no repertório lingüístico, definindo uma nova condição de a criança perceber a forma e o significado da língua de maneira lúdica, estável e acessível. Considerações Finais: O manejo clínico do fonoaudiólogo traz especificidades nas estratégias terapêuticas e oferece maiores e melhores oportunidades de a criança com deficiência auditiva construir suas hipóteses acerca da construção na/da linguagem no processo de aquisição dos sons do PB. Isso se dá, principalmente, a partir de múltiplas oportunidades de feedback auditivo e, portanto, acesso e oportunidades de experiências para a formação de engramas motores de fala. Por isso, consideramos que lançarmos mão da inspeção acústica, relacionando esses dados com a percepção auditiva, nos dá subsídio para um possível entendimento das características fonéticas/fonológicas (além das discursivas e simbólicas) da fala de um sujeito e das possibilidades de percepção e produção de fala, sendo que esses processos implicam em manejos no enquadre terapêutico
138

"Processamento auditivo: teste de fala comprimida em português em adultos normo-ouvintes" / Auditory Processing: a portuguese compressed speech test for normal hearing adults

Rabelo, Camila Maia 02 September 2004 (has links)
Introdução: o teste de fala comprimida é sensível para avaliar o fechamento, porém não é usado no Brasil, pois não existe no português. Objetivo: elaborar um teste de fala comprimida em português aplicá-lo em jovens normo-ouvintes e verificar qual das listas comprimidas (50, 60 e 70%) é a mais apropriada para integrar a grupo de testes de Processamento Auditivo. Método: foram avaliados 144 indivíduos jovens, de ambos os sexos. Foram aplicados os testes de fala comprimida, comparando os resultados de acordo com a orelha inicial, ordem de apresentação e tipo de teste. Resultados: a média de acertos diminui com o aumento da compressão. Conclusão: as listas com compressão de 60% mostraram-se mais estáveis. / INTRODUCTION: The compressed speech test is good for evaluate closure, however it is not used in Brazil because it doesn't exist in portuguese. AIM: make a compressed speech test in portuguese, apply it in normal hearing adults and verify which of the compressed lists (50, 60, 70%) is the most appropriate to be a part of the auditory processing test set. METHOD: 144 individuals of both genders were evaluated. The compressed speech tests were used and the results were compared in respect of inicial ear, order of presentation and monosyllable and bisyllable. RESULTS: the average of correct responses decrease as the compression increase. CONCLUSION: the 60% compression test list shows to be the more stable of them.
139

"Processamento auditivo: teste de fala comprimida em português em adultos normo-ouvintes" / Auditory Processing: a portuguese compressed speech test for normal hearing adults

Camila Maia Rabelo 02 September 2004 (has links)
Introdução: o teste de fala comprimida é sensível para avaliar o fechamento, porém não é usado no Brasil, pois não existe no português. Objetivo: elaborar um teste de fala comprimida em português aplicá-lo em jovens normo-ouvintes e verificar qual das listas comprimidas (50, 60 e 70%) é a mais apropriada para integrar a grupo de testes de Processamento Auditivo. Método: foram avaliados 144 indivíduos jovens, de ambos os sexos. Foram aplicados os testes de fala comprimida, comparando os resultados de acordo com a orelha inicial, ordem de apresentação e tipo de teste. Resultados: a média de acertos diminui com o aumento da compressão. Conclusão: as listas com compressão de 60% mostraram-se mais estáveis. / INTRODUCTION: The compressed speech test is good for evaluate closure, however it is not used in Brazil because it doesn't exist in portuguese. AIM: make a compressed speech test in portuguese, apply it in normal hearing adults and verify which of the compressed lists (50, 60, 70%) is the most appropriate to be a part of the auditory processing test set. METHOD: 144 individuals of both genders were evaluated. The compressed speech tests were used and the results were compared in respect of inicial ear, order of presentation and monosyllable and bisyllable. RESULTS: the average of correct responses decrease as the compression increase. CONCLUSION: the 60% compression test list shows to be the more stable of them.
140

Contribuição do avanço tecnológico do processador de fala para usuários de implante coclear Nucleus 22® / Contribution of the technological advance of the speech processor to patients with Nucleus 22®

Ana Tereza de Matos Magalhães 03 October 2013 (has links)
Objetivo: Identificar as contribuições tecnológicas do processador de fala Freedom® para pacientes implantados com Nucleus 22® e a satisfação dos usuários com a nova tecnologia. Entre os novos recursos disponíveis, foram analisados o efeito da tabela de alocação de frequências, o T-SPL e C-SPL e o ajuste de pré-processamento do som (ADRO®). Material: Este estudo foi prospectivo e exploratório. Foram incluídos adolescentes e adultos implantados com Nucleus 22® no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, usuários efetivos do processador de fala Spectra®, com alguma percepção de frases em contexto fechado e sem experiência anterior com a nova tecnologia. Foram selecionados 17 pacientes, entre as idades de 15 e 82 anos, e implantados há mais de oito anos. Para determinar a contribuição do Freedom®, os limiares auditivos e os testes de percepção de fala foram realizados com o último mapa utilizado com o Spectra® e comparados os mapas criados com o Freedom®. Para identificar o efeito da tabela de alocação de frequências, ambos os mapas convertidos (mesma tabela) e atualizados (tabela nova) foram programados. A tabela escolhida foi mantida, e foram realizados três mapas com diferentes parâmetros: o programa 1 (P1) com T-SPL de 30 dB e do C-SPL de 70 dB, programa 2 (P2) com T-SPL de 25 dB e do C-SPL de 65 dB, e o programa 3 (P3) com ADRO®. A ordem de apresentação dos mapas e dos testes foi randomizada. Para avaliar a satisfação com seus dispositivos auditivos foram utilizados os questionários SADL e APHAB após um mês e um ano de uso do Freedom®. Resultados: A contribuição do processador de fala Freedom® para pacientes usuários do Nucleus 22® foi estatisticamente superior em comparação com o Spectra® em todos os testes de percepção da fala e em todos os limiares audiométricos, tanto individualmente quanto em média, com exceção de 8000 Hz. Em relação à escolha da tabela de frequência, 64,7% dos pacientes (n=11) mantiveram o mapa com a tabela de frequências do Spectra®. Comparando os mapas com diferentes T-SPL e C-SPL, houve diferença estatística tanto nos limiares audiométricos de 500, 1000, 1500 e 2000 Hz quanto na média. Não houve diferença estatística entre os testes de fala com ou sem o uso do ADRO®. Os questionários de satisfação mostraram uma melhora estatisticamente significativa, apenas na subescala que avalia o desempenho em ambiente ruidoso e uso do telefone. Conclusão: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®. A maioria manteve a tabela de frequência original. As mudanças nos parâmetros de T-SPL e C-SPL mostraram uma melhora dos limiares audiométricos nas frequências principais da fala. As diferenças significantes foram sutis nos questionários de satisfação, demonstrando que os pacientes já estavam adaptados e satisfeitos com o implante coclear / Objective: To identify the technological contributions of the Freedom® speech processor to the patients implanted with Nucleus 22® and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL and the pre-processing gain adjustments (ADRO®). Methods: This study was prospective and exploratory. It included teenage and adult patients implanted with Nucleus 22® who effectively used the implant with no previous experience with the new technology and had at least some speech recognition on a closed set with the Spectra® processor. Seventeen patients met the inclusion criteria, ranging in age from 15 to 82 years and deployed for over 8 years. To determine the contribution of the Freedom®, thresholds and speech perception tests were performed with the last map used with the Spectra® and the maps created for Freedom®. To identify the effect of the frequency allocation table, both converted (same table) and upgraded (new table) maps were programmed. The table selected is maintained, and maps were performed with three different parameters: the first program (P1) was programmed with 30 dB T-SPL and 70 dB C-SPL; the second program (P2) with was programmed with 25 dB T-SPL and 65 dB C-SPL; and the program 3 (P3) with ADRO®. The order of presentation of the maps and the testing was randomized. To assess satisfaction were used SADL and APHAB after one moth and one year of using the Freedom®. Results: The contribution of the Freedom® speech processor to patients with the Nucleus 22® was statistically superior compared to the Spectra® in all tests of speech perception and in all audiometric thresholds, both individually and on average, except for 8000 Hz. Regarding the choice of a frequency allocation table, 64.7% of patients (n=11) maintained the same map that had been used with the Spectra® processor. The sound field threshold was statistically significant at 500, 1000, 1500 and 2000 Hz with 25 dB T-SPL/ 65 dB C-SPL. The patients\' satisfaction there was a statistically significant improvement, only in the sub-scale of speech in noise abilities and telephone use. Conclusions: The Freedom® technology improved the performance of patients with the Nucleus 22®. Most of the patients retained the original frequency table. The changes in the parameters of T-SPL and C-SPL showed an improvement in the audiometric thresholds for the main frequencies of speech. Significant differences were subtle in questionnaires of satisfaction, demonstrating that patients were already adapted and satisfied with the cochlear implant

Page generated in 0.0663 seconds