• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 2
  • Tagged with
  • 11
  • 11
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Évaluation des performances du scanner LabPET

Bergeron, Mélanie January 2009 (has links)
Ce mémoire porte sur l'évaluation et l'amélioration des performances du premier appareil commercial de Tomographie d'Émission par Positrons (TEP) pour petits animaux basé sur des détecteurs à photodiode avalanche (PDA) et une électronique de traitement entièrement numérique. Cet appareil est la version améliorée d'un premier prototype TEP basé sur les PDA datant de 1995. Cette nouvelle version a été conçue sur une plateforme électronique numérique pour améliorer à la fois la résolution spatiale, permettant de détecter de plus petites structures chez la souris, et la sensibilité afin d'injecter une dose de radiotraceur plus faible à l'animal. Le but d'utiliser une électronique numérique était d'augmenter la flexibilité du traitement des signaux pour l'adapter selon de nouvelles applications. Afin de vérifier toutes ces caractéristiques potentielles, nous avons effectué une évaluation systématique et exhaustive des performances de ce nouveau scanner (désigné sous le sigle commercial « LabPET ») pour l'application en imagerie moléculaire. Des procédures d'ajustement automatique de plusieurs paramètres du scanner, dont la tension de polarisation des détecteurs PDA dans les conditions optimales d'opération, ont été mises au point pour faciliter l'étalonnage du grand nombre de détecteurs (1536 ou 3072 selon la version du scanner). Une technique pour normaliser les délais temporels de chaque détecteur a permis d'améliorer les performances temporelles du scanner et la qualité d'image. Cette technique a aussi servi à caractériser de façon individuelle les détecteurs au niveau de leur résolution en temps, ce qui permet de connaître leurs performances et de suivre leur possible dégradation à long terme. Par la suite, les performances de l'appareil pour l'imagerie, telles que la résolution spatiale et temporelle, la résolution en énergie, la sensibilité, le temps mort et le taux de comptage, ont été mesurées en suivant dans la mesure du possible les recommandations des normes de la National Electrical Manufacturers Association (NEMA) pour l'évaluation d'appareils d'imagerie. De plus, des balises pour l'élaboration de protocoles d'acquisition ont été établies afin d'obtenir des images optimales. Pour ce faire, une caractérisation plus exhaustive de la qualité d'image à l'aide de mires et d'images de rats et de souris a été réalisée. Deux appareils avec champ axial de 3.75 et 7.5 cm ont été caractérisés dans le cadre de ce projet de maîtrise. À la suite de toutes les améliorations apportées à l'appareil et à la lumière des résultats obtenus, la plupart des concepts utilisés pour la fabrication de l'appareil ont conduit à des images de qualité supérieure.
2

Réalisation d'un nouveau prototype combiné TEP/TDM pour l'imagerie moléculaire de petits animaux

Bérard, Philippe January 2010 (has links)
Au cours des dernières années, la tomographie d'émission par positrons (TEP) s'est imposée comme l'outil diagnostique par excellence pour déceler la présence de tumeurs et caractériser leur statut métabolique. Comme les images TEP souffrent généralement d'une localisation anatomique imprécise, le diagnostic est d'autant plus fiable lorsque l'information fonctionnelle et moléculaire fournie par la TEP peut être complétée par l'information anatomique détaillée obtenue par une autre modalité d'imagerie comme la tomodensitométrie (TDM) ou l'imagerie par résonance magnétique (IRM). L'émergence de l'imagerie multi-modale TEP/TDM (ou"PET/CT") permet d'obtenir, à tour de rôle, l'information anatomique et métabolique du patient en effectuant successivement les examens TDM et TEP sans avoir à déplacer le patient d'une salle à l'autre, ce qui facilite beaucoup les procédures de recalage d'images. Toutefois, il peut arriver, vu le déplacement du lit du patient d'un scanner à l'autre, que le patient bouge volontairement ou involontairement (mouvement péristaltique, cardiaque ou pulmonaire), ce qui cause des imprécisions dans les images fusionnées. Afin d'éviter ce problème, un simulateur TEP/TDM reposant sur un système de détection commun, celui du scanner LabPET(TM), a été développé. Détectant à la fois le rayonnement émis par le radiotraceur utilisé en TEP et les rayons-X de plus faible énergie utilisée en TDM, des images TEP/TDM ont été obtenues sans aucun déplacement du sujet. Pour obtenir ces images, des algorithmes numériques de traitement de signal ont été développés afin de diminuer l'empilement de signaux et ainsi mieux discerner les photons incidents du niveau de bruit électronique. De plus, des algorithmes de reconstruction d'images adaptés à la géométrie du simulateur ont été développés. Les résultats obtenus ont démontré qu'il est possible d'obtenir, avec relativement peu de radiations ionisantes, des images anatomiques avec un contraste suffisant pour l'imagerie moléculaire. Cependant, la résolution spatiale obtenue avec cet appareil n'était pas suffisante pour bien identifier les structures anatomiques fines chez la souris (le modèle animal par excellence en recherche biomédicale). Le détecteur LabPET II, dont les pixels font 1.2 × 1 2 mm[indice supérieur 2] a donc été développé afin d'atteindre une résolution submillimétrique en imagerie TEP et de l'ordre de 500 [micro]m en imagerie TDM. Fabriqué à partir de deux matrices de photodiodes avalanches, ce détecteur comptant 64 canaux d'acquisition individuels a été caractérisé ainsi que son électronique. Le rehaussement du simulateur avec ces détecteurs permettra de construire sous peu le premier appareil TEP/TDM avec un nouveau système de détection. Les applications de ce type d'appareil en recherche sur modèle animal sont nombreuses et diversifiées : étude de la croissance normale, étude de l'évolution des maladies et évaluation de l'efficacité des thérapies, développement de produits radiopharmaceutiques, etc.... Chez l'humain, l'approche TEP/TDM combinée proposée permettra d'améliorer la détection précoce des cancers et de faciliter le suivi des patients sous thérapie grâce à une réduction importante des doses de radiations.
3

Étalonnage automatique des détecteurs pour scanner LabPET II

Jürgensen, Nadia January 2017 (has links)
Depuis une vingtaine d'années, le GRAMS et le CIMS travaillent en collaboration dans le domaine de l'imagerie médicale, plus précisément sur la tomographie d'émission par positrons destinée à la recherche préclinique sur petits animaux. Après le scanner TEP Sherbrooke en 1994 et le LabPET I commercialisé par Advanced Molecular Imaging (AMI) Inc., Gamma Medica Ideas et GE Healthcare au cours des années 2000, l'aspiration vers de meilleures performances est le moteur de la réalisation d'une nouvelle version : le LabPET II. L'augmentation importante du nombre de détecteurs, nécessaire pour atteindre une meilleure résolution spatiale, amène de nouveaux défis autant sur le plan matériel que logiciel. Un des défis est de compenser les disparités en gain des détecteurs à base de photodiodes à avalanche (PDA) qui engendrent des différences intercanaux. Le but de ce projet de maîtrise est de développer et d'implémenter un algorithme capable de corriger ces différences de façon automatisée.
4

Apport des photodiodes à avalanche HgCdTe pour la télédétection du CO2 atmosphérique par lidar DIAL à 2 micromètres / Optical remote sensing of atmospheric carbon dioxide using a 2 µm differential absorption lidar and HgCdTe avalanche photodiodes

Dumas, Arnaud 01 December 2016 (has links)
L’infrarouge proche (1.5-2μm) ou SWIR (Short Wavelength Infrared) est une région particulièrement adaptée à la mesure de gaz à effet de serre par lidar à absorption différen- tielle (DIAL). En effet, (i) cet intervalle spectral contient des raies d’absorption intenses pour les principaux gaz à effet de serre (CO2, CH4, H2O, etc.) (ii) le taux d’extinction lors de la propagation du faisceau laser y est faible (iii) c’est une région spectrale dite en sécurité oculaire. Bien qu’abordée avec les moyens existants (détection hétérodyne), la mesure DIAL dans le SWIR a longtemps souffert de l’absence de photo-détecteurs ultra-sensibles. Les développements récents (années 2000) portant sur les photodiodes à avalanche (APD) HgCdTe ont changé la donne. En effet, ces dernières présentent de remarquables qualités d’amplification car elles allient trois propriétés fondamentales : un faible excès de bruit, un très faible courant d’obscurité et des gains importants. De telles propriétés sont essentielles pour les applications reposant sur la détection de très faibles signaux et en particulier le lidar.Dans cette thèse, nous analysons les performances d’un détecteur monopixel (200 μm) à base d’APD HgCdTe (conçu sur mesure par le CEA-LETI) dans le cadre de mesures expérimentales de la concentration de CO2 atmosphérique par lidar DIAL. L’émetteur laser est également un prototype, précédemment développé au Laboratoire de Météoro- logie Dynamique. Il produit alternativement des impulsions de 10 mJ à deux fréquences contrôlées dans la plage 2050-2054nm, le tout à une fréquence de répétition de 2kHz. Grâce à l’association de ces deux technologies de pointe nous avons pu effectuer les pre- mières mesures DIAL utilisant la technologie HgCdTe APD.Les expériences menées nous ont permis de confirmer le remarquable niveau de per- formances en sensibilité attendu (75 photons de bruit par temps caractéristique d’une bande passante de 20 MHz) et soulignent le potentiel futur d’un tel capteur pour toutes les applications faible flux dans le SWIR. Concernant les mesures DIAL, nous avons ob- tenu expérimentalement une précision relative de 10-20 % sur la concentration en CO2 pour une mesure dans la couche limite avec une résolution de 100 m - 4 s sur une portée de 1.5km. Par ailleurs, l’analyse fine de la réponse impulsionnelle de la photodiode à avalanche révèle une dégradation notable du long term settling time lorsqu’on la pola- rise. Ce phénomène contraint la plage d’utilisation du capteur, ce que nous discutons en tenant ce comportement du détecteur dans une simulation lidar. / The Short Wavelength Infrared (SWIR) region (1.5-2 μm) is well adapted for diffe- rential absorption lidar technique (DIAL) for several reasons : (i) it covers absorption bands with suitable intensity for the main greenhouse gases (CO2, CH4, H2O, etc.) (ii) the extinction due to particles is low (iii) it belongs to the eye safe domain. However, one main drawback has long been the lack of efficient photodetectors for such frequencies. A major enhancement occurred in the early 2000s when it was understood that HgCdTe avalanche photodiodes (APD) present close to unity excess noise factor on top of high gain and very low dark current. These features make this technology an almost ideal amplifier, especially useful for ultra low flux applications such as lidar.In this thesis, we analyze the performances of a custom large diameter (200μm) monopixel HgCdTe-APD based detector (designed at CEA-LETI) in the framework of atmospheric CO2 measurements with the DIAL technique. The laser emitter, a custom solid-state Ho :YLF laser developed at the Laboratoire de Météorologie Dynamique, is tunable in the 2050-2054nm range and produces 10 mJ pulses at a repetition rate of 2kHz. This emitter is associated to a detection chain adapted to the HgCdTe APD based detector to provide the first atmospheric DIAL measurements using the HgCdTe APD technology.Experiments confirmed the outstanding sensitivity of the detector (75 noise photons per characteristic time given a 20MHz bandwidth) and highlight the huge potential of this technology for any application relying on low light flux detection in SWIR. With the system previously mentioned, we reach an precision of 10-20 % on CO2 mixing ratio for a time-space resolution of 100 m and 4 s for measurements in the atmospheric boundary layer. Regarding the detector impulse response, we have shown evidence of a negative influence of reverse bias on the long term settling time of the APD. This phenomenon limits the dynamic range of useful signals and contraints the DIAL system. Thanks to numerical simulation taking into account this behaviour, we derive numerically expected biases on DIAL measurements.
5

Contribution à l'étude et la réalisation de systèmes de transmissions optiques sécurisées

Dinh Xuan, Quyen 12 July 2007 (has links) (PDF)
Les travaux de cette thèse s'inscrivent dans le cadre de la cryptographie, et plus précisément de la cryptographie quantique. Le but est de concevoir un système permettant de transmettre simultanément une clé de cryptage et un signal horloge dans une même fibre optique (à la longueur d'onde des télécommunications soit 1550 nm) en essayant d'éviter les effets de la dispersion chromatique. En effet le signal représentant la clé de cryptage doit être réalisé sous forme d'impulsions fortement atténuées simulant des photons uniques et dans ces conditions il est nécessaire de disposer au niveau du détecteur d'un signal horloge donnant l'instant d'arrivée des impulsions. Nous fabriquons deux signaux de longueurs d'onde très proches (écart de 0,88 pm) grâce à un modulateur acousto-optique, chacune servant de porteuse à un des deux signaux. A la réception il est nécessaire de séparer ces deux longueurs d'ondes et pour cela un filtre basé sur un interféromètre de Fabry-Pérot a été conçu, réalisé, testé et mis en oeuvre au laboratoire. Puis nous avons aussi réalisé un photodétecteur basé sur une photodiode à avalanche, dont nous pouvons abaisser la température de fonctionnement jusqu'à environ 0°C. Le système a été entièrement réalisé et nous avons pu montrer la faisabilité de cette technique. Des améliorations restent à apporter en particulier sur la stabilité du filtre optique et sur le fonctionnement du détecteur en mode comptage de photons.
6

Design of an integrated streak camera based on a time correlated single photon counting system / Conception d'une caméra à balayage de fente intégrée basée sur un système de comptage de photon unique résolu en temps

Malass, Imane 13 May 2016 (has links)
Nous présentons une caméra à balayage de fente intégrée basée sur un système de comptage de photon unique résolu en temps (TCSPC-SC) employant l'architecture linéaire « streak » pour surmonter la limitation de l'espace inhérent aux systèmes TCSPC bidimensionnels. Cette solution permet l'intégration de fonctionnalités électroniques complexes dans les pixels sans l'inconvénient d'un faible facteur de remplissage conduisant à une faible efficacité de détection. Le TCSPC-SC se compose de deux blocs principaux: une photodiode à avalanche (SPAD) et un bloc de mesure de temps, les deux blocs sont intégrés en technologie 180 nm CMOS standard. La structure de la SPAD utilisée a été sélectionnée parmi 6 structures différentes après un processus de caractérisation précise et approfondie. Le bloc de mesure du temps se compose d'un TOC hybride capable d'atteindre des résolutions de temps élevées et ajustables avec une large dynamique de mesure grâce à un système de conversion de temps (TOC) hybride qui combine l'approche analogique basée sur un convertisseur de temps vers amplitude(TAC), et les approches numériques utilisant une boucle à verrouillage de retard (DLL) et un compteur numérique. Le TOC hybride a été spécialement conçu pour être utilisé dans un système TCSPC qui intègre une ligne de TOC nécessitant ainsi une conception appropriée pour limiter la consommation d'énergie et la surface d'occupation et parvenir à une architecture flexible et facilement extensible. Suite à la conception et la réalisation de ces deux blocs dans une technologie180 nm CMOS standard, une structure de test de la caméra à balayage de fente (TCSPC-SC) qui englobe 8 unités a été réalisée dans le but final de mettre en œuvre un modèle TCSPC-SC complet et plus large. / In this work we present a TCSPC Streak Camera (TCSPC-SC) that takes advantage of the streak mode imaging ta overcome the space limitation inherent ta 20 TCSPC sensor arrays. This cost-effective solution allows the integration of complex functionalities in the pixel without the inconvenience of low fill factor that leads ta low detection efficiency. The TCSPC~SC consists of two main building blacks: a SPAD and a time measurement black bath integrated in 180 nm Standard CMOS technology. The SPAD was selected among 6 different SPAD structures following a thorough characterization process ta fully determine its performance figures. The time measurement black consists of a hybrid TOC capable of achieving high adjustable time resolutions with large dynamic range owing ta a time conversion scheme that combines traditional Analog Time to Amplitude Converter (TAC), Digital DLL-based and counter-based TOC. Furthermore, thehybrid TOC was especially designed ta be used in a TCSPC system that incorporates an array of TDCs which required a careful design ta limit power consumption and occupation area in order to achieve a flexible and easily scalable architecture. These two building blacks were bath fabricated in a 180 nm standard CMOS technology and employed ta demonstrate a TCSPC Streak Camera(TCSPC-SC) test structure that englobes 8 units in order ta demonstrate the system's operation principle with the final aim of implementing a complete and bigger TCSPC-SC model in the near future
7

Conception et développement d'un luminomètre portable ultrasensible pour la détection de la bioluminescence / Conception and development of an ultrasensitive portable luminometer for the bioluminescence detection

Kayaian, Jean 16 December 2010 (has links)
Le développement d'un produit portable et performant, tout en limitant les coûts, répond à la croissance du marché de la détection biologique par la méthode de la biochimiluminescence. Cet outil de diagnostic d'hygiène et de qualité en temps réel in situ permet une meilleure sécurité, gestion des risques, traçabilité et surveillance des risques. Cet outil trouvera son application dans les domaines agroalimentaires, médicaux, pharmaceutiques, cosmétologiques, environnementaux (eau, air, surfaces), le tertiaire ou les collectivités. Les intérêts sont industriels, écologiques et économiques, et reflètent le désir de proposer un produit novateur et compétitif sur un marché en plein essor. En effet, la détection de certains contaminants est devenue une priorité dans la gestion des risques microbiologiques. La plupart des méthodes de diagnostic actuelles sont lentes, coûteuses, complexes, et limitées dans leur mise en uvre et leurs résultats. Le diagnostic étant essentiel dans tous les secteurs d'activité, il est impératif d'apporter des solutions alternati ves de détection et de quantification des germes pathogènes ou autre toxiques, par la conception de nouveaux outils d'analyse sur le terrain, en temps réel, avec une rapidité et une sensibilité élevées. Ceci passe par une étude fine des phénomènes de biochimiluminescence (BCL) et par la recherche des différents composants optoélectronique capables de détecter les faibles puissances lumineuses émises. Le projet de conception d'un luminomètre de terrain à base de photodiodes PIN ou avalanche, ou de photomultiplicateurs répond aux besoins de la détection et de la mesure de la puissance lumineuse rayonnée par des réactions spécifique ou non de biochimiluminescence. L'élaboration d'un appareil de mesure portable destiné à la quantification in situ de biomasse ou molécules à l'état de traces est nécessaire à l'exploitation des réactifs. En effet, les appareils existants fournissent une information en RLU (Relative Light Unit, unité arbitraire qui né cessite une comparaison à un étalon connu) et ne donnent pas une information quantifiée directe sur la concentration de l'élément recherché dans l'échantillon testé. Ils ne permettent donc pas d'optimiser la biochimiluminescence sur le terrain. L'objectif de ce travail est de mettre au point une alternative plus performante que les systèmes de détection actuels et qui soit moins onéreuse. / The development of a portable and efficient device, while reducing costs, meets the growing market for biological detection by the method of biochimiluminescence. This diagnostic tool of hygiene and quality in real time in situ allows for better security, risk management, traceability and risk monitoring.This tool will find application in the areas food, medical, pharmaceutical, cosmetic, environmental (water, air and surfaces), the tertiary or communities. Interests are industrial, environmental and economic, and reflect the desire to offer an innovative and competitive device in a booming market.Indeed, the detection of contaminants has become a priority in the management of microbiological hazards. Most current diagnostic methods are slow, costly, complex and limited in their implementation and their results.The diagnosis is essential in all industries, it is imperative to provide alternative solutions for the detection and quantification of pathogens or other toxic by the conception of new analytical tools in situ in real time with speed and high sensitivity. This requires a detailed study of biochimiluminescence (BCL) phenomena and the search for various optoelectronic components capable of detecting low power emitted light.The projet for the conception of a field-luminometer based on avalanche photodiodes, or PIN, or photomultiplier responds to the needs of detecting and measuring the light power radiated by reactions biochimiluminescence specific or not. The development of a portable measuring device for in situ quantification of biomass or molecules trace is necessary for the operation of the reactants.Indeed, existing devices provide information in RLU (Relative Light Units, arbitrary units implying a comparison to a known standard) and do not give a direct quantified information on the concentration of the desired item in the test sample. So, they do not optimize biochimiluminescence field. The objective of this work is to develop an alternative more efficient than current detection systems and is less expensive.
8

Conception des circuits de polarisation des détecteurs et de maintien de la tension de base du LabPET II

Panier, Sylvain January 2014 (has links)
Par le passé, la collaboration entre le Centre d'Imagerie Médicale de Sherbrooke (CIMS) et le Groupe de Recherche en Appareillage Médicale de Sherbrooke (GRAMS) a permis de développer le scanner LabPET. Celui-ci fut le premier scanner de Tomographie d'Émission par Positrons (TEP) commercial utilisant des photodiodes à effet avalanche (PDA) comme détecteur. Depuis, cette collaboration a permis de faire évoluer le scanner afin d'améliorer cette modalité d'imagerie et d'y ajouter la tomodensitométrie (TDM). Les attentes pour la prochaine génération du scanner sont donc grandes. Cette nouvelle génération du scanner, le LabPET II, verra les deux modalités nativement intégrées et elles utiliseront la même chaine de détection. Ce scanner se verra doté de nouveaux détecteurs organisés en matrices de 64 cristaux de 1,1 par 1,1 mm². Cette nouvelle matrice, associée à ses deux matrices de 32 PDA, a prouvé sa capacité à fournir une résolution spatiale inférieure au millimètre. L'utilisation de ce nouveau module de détection pourra donc permettre au LabPET II d'être le premier scanner bimodal (TEP/TDM) commercial atteignant une résolution submillimétrique. Ce scanner permettra de s'approcher un peu plus de la résolution spatiale ultime en TEP tout en permettant une bonne localisation anatomique grâce à l'ajout d'une imagerie TDM rudimentaire. Pour atteindre ces objectifs, une intégration complète de l'électronique frontale a été nécessaire. Dans les versions précédentes, seuls les préamplificateurs de charge et les filtres de mise en forme étaient intégrés; dans cette nouvelle version, toute l'électronique analogique ainsi que la numérisation et les liens de communications devront être intégrés. Pour ce faire, la technique de temps de survol au-dessus d'un seuil (ou ToT pour «Time-over-Threshold») a été préférée à la solution utilisée par le LabPET I qui nécessitait un convertisseur analogique-numérique par canal. La contrepartie de cette solution est l'obligation de maintenir la tension de base à une valeur fixe et commune à tous les canaux. Le circuit de polarisation des PDA a aussi dû être intégré dans l'ASIC, car il occupait énormément de place sur la carte d'électronique frontale du LabPET 1. Dans ce mémoire seront décrits la conception, l'intégration et les tests de ces deux circuits du système. Ils ont démontré leur efficacité tout en n'occupant que très peu de place dans le circuit intégré spécialisé (ASIC) du «module de détection». Au vu des sources bibliographiques recensées, le module de détection du LabPET II devrait être l'un de ceux ayant la plus forte densité de canaux (environ 45 par centimètre carré) et le seul combinant électronique analogique faible bruit, numérique et haute tension (~450 V). La réalisation de cette nouvelle génération devrait permettre au partenariat CIMS/GRAMS de réaffirmer leur position de leader dans le domaine en améliorant les outils d'imagerie à la disposition des chercheurs en médecine préclinique.
9

Intégration de mélangeurs optoélectroniques en technologie CMOS pour la télémétrie laser embarquée haute résolution / Integration in CMOS technology of optoelectronic mixer for high resolution embedded laser range-finding systems

Moutaye, Emmanuel 17 December 2010 (has links)
La mesure de distance et la détection d'objets sont devenues essentielles dans de nombreux domaines tels que l'automobile ou la robotique, les applications médicales, les procédés industriels et agricoles, les systèmes de surveillance et de sécurité, etc. Dans le but d'améliorer les performances des dispositifs de télémétrie laser en terme de bruit et de diaphonie, une technique hétérodyne par mélange optoélectronique doit être utilisée. Par ailleurs, l'aspect système embarqué nécessite une réduction de l'encombrement et de la consommation à performances égales. L'intégration de mélangeurs optoélectroniques en technologie CMOS apporte donc une solution optimale à cette approche grâce à ses multiples avantages (intégration du circuit d'instrumentation sur la même puce, modèles bien connus, coût raisonnable, performances élevées,…). Ainsi cette thèse traitera de l'étude de mélangeurs optoélectroniques en technologie CMOS pour la télémétrie embarquée haute résolution. Le premier chapitre de ce manuscrit présente les diverses technique de mesure de distance par télémétrie laser par et justifie le choix de la télémétrie laser par déphasage ainsi que le gain en performances lié à l'hétérodynage. Le second chapitre décrit les mélangeurs électriques et optoélectroniques ainsi que les propriétés nécessaires à leur réalisation. Quelques photodétecteurs y sont présentés au vu de la possibilité de les utiliser en mélangeurs optoélectroniques et d'une intégration potentielle en technologie CMOS. Les principales contraintes liées à l'intégration en technologie CMOS de photocapteurs utilisables en mélangeurs optoélectroniques, sont exposés dans la troisième partie. Les travaux de conception et d'optimisation des structures ainsi que les phases de simulations et de test y sont détaillés. Enfin, pour valider expérimentalement les études précédentes, le dernier chapitre présente la conception d'une chaîne de mesure multivoies pour une tête de photoréception CMOS matricée pour un télémètre laser embarqué haute résolution. / Distance measurement and object detection has become essential in many fields such as automotive and robotics, medical applications, industrial processes and farming systems, surveillance and security, etc.. In order to improve the performance of laser ranging devices in terms of noise and crosstalk, an optoelectronic heterodyne technique of mixing should be used. Moreover, the aspect of embedded system requires a reduction in the size and power consumption for the same performance. The integration of optoelectronic mixers in CMOS technology will provide an optimal solution to this approach through its many advantages (integrated instrumentation circuit on the same chip, well-known models, reasonable cost, high performance, ...). Thus this thesis will focus on the study of optoelectronic mixers in CMOS technology for high resolution, embedded laser range finding systems. The first chapter of this thesis discusses the various technique of distance measurement by laser ranging and justifies the choice of phase shift technique and the gain in performance related to heterodyning. The second chapter describes the electrical and optoelectronic mixers and the properties needed to develop them. Some photodetectors are presented given the opportunity to use optoelectronic mixers and a potential integration with CMOS technology. The main constraints to the integration of CMOS photosensors used in optoelectronic mixers are set out in Part III. The work of design and optimization of structures and phases of simulations and testing are detailed. Finally, to experimentally confirm the earlier studies, the final chapter presents the design of a measuring head for a multichannel photoreceptor CMOS for a high resolution laser range finder.
10

Conception des circuits de polarisation des détecteurs et de maintien de la tension de base du LabPET II

Panier, Sylvain January 2014 (has links)
Par le passé, la collaboration entre le Centre d'Imagerie Médicale de Sherbrooke (CIMS) et le Groupe de Recherche en Appareillage Médicale de Sherbrooke (GRAMS) a permis de développer le scanner LabPET. Celui-ci fut le premier scanner de Tomographie d'Émission par Positrons (TEP) commercial utilisant des photodiodes à effet avalanche (PDA) comme détecteur. Depuis, cette collaboration a permis de faire évoluer le scanner afin d'améliorer cette modalité d'imagerie et d'y ajouter la tomodensitométrie (TDM). Les attentes pour la prochaine génération du scanner sont donc grandes. Cette nouvelle génération du scanner, le LabPET II, verra les deux modalités nativement intégrées et elles utiliseront la même chaine de détection. Ce scanner se verra doté de nouveaux détecteurs organisés en matrices de 64 cristaux de 1,1 par 1,1 mm². Cette nouvelle matrice, associée à ses deux matrices de 32 PDA, a prouvé sa capacité à fournir une résolution spatiale inférieure au millimètre. L'utilisation de ce nouveau module de détection pourra donc permettre au LabPET II d'être le premier scanner bimodal (TEP/TDM) commercial atteignant une résolution submillimétrique. Ce scanner permettra de s'approcher un peu plus de la résolution spatiale ultime en TEP tout en permettant une bonne localisation anatomique grâce à l'ajout d'une imagerie TDM rudimentaire. Pour atteindre ces objectifs, une intégration complète de l'électronique frontale a été nécessaire. Dans les versions précédentes, seuls les préamplificateurs de charge et les filtres de mise en forme étaient intégrés; dans cette nouvelle version, toute l'électronique analogique ainsi que la numérisation et les liens de communications devront être intégrés. Pour ce faire, la technique de temps de survol au-dessus d'un seuil (ou ToT pour «Time-over-Threshold») a été préférée à la solution utilisée par le LabPET I qui nécessitait un convertisseur analogique-numérique par canal. La contrepartie de cette solution est l'obligation de maintenir la tension de base à une valeur fixe et commune à tous les canaux. Le circuit de polarisation des PDA a aussi dû être intégré dans l'ASIC, car il occupait énormément de place sur la carte d'électronique frontale du LabPET 1. Dans ce mémoire seront décrits la conception, l'intégration et les tests de ces deux circuits du système. Ils ont démontré leur efficacité tout en n'occupant que très peu de place dans le circuit intégré spécialisé (ASIC) du «module de détection». Au vu des sources bibliographiques recensées, le module de détection du LabPET II devrait être l'un de ceux ayant la plus forte densité de canaux (environ 45 par centimètre carré) et le seul combinant électronique analogique faible bruit, numérique et haute tension (~450 V). La réalisation de cette nouvelle génération devrait permettre au partenariat CIMS/GRAMS de réaffirmer leur position de leader dans le domaine en améliorant les outils d'imagerie à la disposition des chercheurs en médecine préclinique.

Page generated in 0.0907 seconds