• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 122
  • 118
  • 64
  • 33
  • 22
  • 19
  • 18
  • 16
  • 14
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Sistema automatizado baseado em língua eletrônica para monitoração de água para abastecimento urbano. / Automated system based on electronic tongue system for urban water supply monitoring.

Braga, Guilherme de Souza 12 December 2011 (has links)
A presente tese trata do desenvolvimento de uma língua eletrônica (LE) e da avaliação de seu uso na detecção de 2-metilisoborneol (MIB), geosmina (GEO) e isoborneol (ISO) em amostras de água. A água abastecida à região metropolitana de São Paulo provém de mananciais, os quais estão sujeitos à ploriferação de algas (eutrofização). Muitas delas podem ser tóxicas e ainda produzir compostos, como MIB e GEO, substâncias reconhecidas por provocar gosto e odor desagradáveis na água que consumimos. De fato, a presença de MIB e GEO na água é uma das maiores fontes de reclamação por parte dos consumidores junto à companhia de saneamento e abastecimento de São Paulo (SABESP). Apesar disso, ainda não existem tecnologias que possam ser aplicadas para a detecção in locu dessas substâncias. A LE usada nesta tese foi baseada em um arranjo de sensores químicos não-específicos, formados por microeletrodos interdigitados de ouro recobertos com filmes poliméricos nanoestruturados depositados pela técnica de automontagem e interrogados sob regime de corrente alternada. A calibração da LE foi realizada com soluções de concentração determinada de GEO, MIB e ISO preparadas em água destilada, mineral e de torneira. Foram avaliadas tanto soluções individuais contendo um único contaminante, quanto misturas contendo MIB e GEO. A resposta elétrica dos sensores (medidas de capacitância), foram interpretadas por análise das componentes principais (PCA) e por lógica Fuzzy, com as quais a LE consegue discriminar as diversas amostras com relativa facilidade e confiabilidade. Dentre as principais observações dessa investigação, notou-se que a LE desenvolvida consegue detectar MIB e GEO em amostras de água reais em concentrações tão baixas quanto 20 ng L-1. Os gráficos de PCA mostram a separação das amostras em clusters relativamente pequenos, bem separados e sem sobreposição. A LE é capaz de identificar de forma direta, a partir de variações na primeira componente principal, variações na razão molar nGEO/nMIB em misturas de MIB e GEO. Em um caso mais próximo da realidade, a LE consegue discriminar com relativa facilidade, amostras de água fornecidas pela SABESP, coletadas do sistema Guarapiranga antes e após a estação de tratamento. As taxas de acerto da LE usando os controladores Fuzzy desenvolvidos são próximas de 100% para a maioria das amostras. A menor taxa de acerto (93,33%) ocorreu com as amostras preparadas em água de torneira. Adicionalmente, nenhuma amostra de água pura foi classificada como contendo algum contaminante, ou seja, não houve falsos positivos. Conclui-se, portanto que a LE desenvolvida, tanto em termos de sensores quanto de análise de dados, apresenta potencial para monitoramento de MIB e GEO nos reservatórios de água, fornecendo em tempo real e in loco informações sobre a qualidade da água provinda da estação de tratamento. A tese também apresenta alguns resultados da preparação de filmes poliméricos com impressão molecular para aplicação em sensores específicos, obtidos durante o estágio na Universidade Autônoma de Barcelona. / Water from São Paulo metropolitan area comes from water reservoirs, which are prone to algae bloom (eutrophication). These algae can be toxic and produce compounds, such as geosmin (GEO) and 2-methylisoborneol (MIB) that give unpleasant taste and odour to the water supplied to consumers. In fact, their presence in water is one of the major complains of consumers to São Paulo\'s water company (SABESP). Despite that, technologies that can be applied for monitoring these substances in real time and in locu are still not available. In this sense, the present thesis work has focused on the development of an electronic tongue system (ET) and evaluate its performance on detecting MIB, GEO and isoborneol (ISO) in water samples. The ET is based on an array of non-specific chemical sensors, which are made of gold interdigitated microelectrodes covered with nanostructured polymeric films deposited via the layer-by-layer technique and interrogated in alternate current regime. The ET calibration was conducted by analyzing distilled, mineral and tap water samples tainted with known concentrations of MIB, GEO and ISO. The samples were solutions with a single tainting compound and solutions containing MIB and GEO mixed together. The sensors\' electrical response (capacitance measurements) was interpreted by principal component analysis (PCA) and Fuzzy logic. Among the main features of this work, the present ET presents a detection limit of about 20 ng L-1 for both tainting compounds. The ET can also discriminate with great easiness and confiability individual and mixture samples. PCA plots show that samples are grouped into relatively small and well-separeted clusters (no overlapping). The ET is also capable of detect, based on changes on the first principal component, changes in the nGEO/nMIB molar ratio of mixed samples. Also, the ET can discriminate with great easiness, water samples supplied by SABESP, collected at Guarapiranga\'s reservoir, before and after the water treatment plant. The influence of the water type on the sensors\' response has little significance when the Fuzzy controller is employed. The ET with the Fuzzy controller presents an excellent performance with very low error rates: 0.25% (distilled water), 5% (mineral water) and 6.66% (tap water). Besides that, Fuzzy logic results can be displayed in simpler plots which ensures easier readings of hit and error rates of the ET. Also, the numeric values (compound concentration) can be replaced by linguistic variables such as proper and improper. Finally, it can be concluded that the ET developed herein, when considering sensor and data analysis, shows a great potential for monitoring MIB and GEO in water reservoirs, providing in real time and in locu information about water quality in treatment stations. This thesis also presents the study on the assembly of molecularly imprinted polymeric films to be used in specific chemical sensors, carried out during the internship at the Universidade Autonoma de Barcelona.
102

Reuso potável de esgoto sanitário: possibilidades e riscos / Potable reuse of wastewater: opportunities and risks

Rezende, Carlos Custódio Santos de 15 October 2010 (has links)
O atual cenário de escassez hídrica enfrentada por certas regiões e o crescente grau de poluição dos recursos hídricos motivam pesquisas por alternativas para suprir esse déficit, uma vez que a água é um dos mais importantes recursos. Nesse cenário o reuso de água é uma importante e estratégica alternativa de instrumento de gestão de recursos hídricos, pois ao mesmo tempo em que reduz a pressão sob as fontes de água, também reduz significativamente os impactos gerados pelos lançamentos de esgotos em corpos receptores. Desse modo, o trabalho contemplou uma modalidade de reuso ainda não muito estudada, o reuso potável. Por ser uma modalidade que apresenta grandes riscos o trabalho se apoiou nos três aspectos principais associados: tecnologia, escassez e aceitação da população. O trabalho apresenta um estudo de caso para região metropolitana de Vitória, onde foi realizada uma projeção da demanda por recursos hídricos para curto (2015), médio (2020) e longo (2030) prazos, que quando comparada com a disponibilidade hídrica da região, concluiu que num futuro próximo (2015) a demanda será maior que a oferta. Para suprir esse déficit foi proposta uma alternativa de sistema de reuso potável indireto e feito uma avaliação da aceitação da população. / The current scenario of water scarcity faced by some regions and increasing degree of pollution of water resources motivate researches for alternatives to supply this deficit, since water is one of the most important resources. In this scenario, water reuse is an important and strategic alternative tool of water resources management, because while it reduces the pressure on water supplies, also significantly reduces the impacts caused by sewage discharge into receiving bodies of water. Thus, the work contemplated a form of reuse that is not so well studied, the potable reuse. Being a type that presents great risks, the work was supported in three main aspects associated with: technology, scarcity and public acceptance. The work presents a case study for the metropolitan region of Vitória, projected water demands for short (2015), medium (2020) and long (2030) terms, that when compared to water availability in the region, concluded that in the near future (2015) demand will be greater than the supply. To increase the disponibility of water was proposed an alternative system of indirect potable reuse and made an assessment of public acceptance.
103

Remoção do ácido 2,4 diclorofenoxiacético (2,4-D) por adsorção em carvão ativado pulverizado associado ao tratamento convencional de água para consumo humano / Removal of acid 2,4-dichlorophenoxyacetic (2,4-D) in powdered activated carbon adsorption associated with conventional drinking water treatment

Leal, Waldiléia Pereira 05 July 2013 (has links)
Made available in DSpace on 2016-12-23T14:04:29Z (GMT). No. of bitstreams: 1 Waldileia Pereira Leal.pdf: 3453316 bytes, checksum: 63c0a56552f4b09c97956f4c0d9f711c (MD5) Previous issue date: 2013-07-05 / O 2,4-D é o segundo herbicida mais utilizado no Brasil, podendo chegar à água de abastecimento público. Devido à limitação do tratamento convencional na remoção de microcontaminantes e a capacidade do carvão ativado em removê-los, este estudo investigou a aplicação de carvão ativado pulverizado (CAP) na remoção do 2,4-D por processos de adsorção associado ao tratamento convencional utilizando água bruta do Rio Santa Maria da Vitória em equipamentos de jartest. Os diagramas de coagulação foram construídos através de estudo de tratabilidade de água utilizando o sulfato de alumínio e o policloreto de alumínio como coagulantes. Foram realizados ensaios de adsorção com carvões derivados da casca de coco (CAP 1) e de pinnus (CAP 2) que foram caracterizados e avaliados na sua capacidade de remover o 2,4-D. A remoção de matéria orgânica natural também foi determinada pela medição de carbono orgânico dissolvido (COD) e absorvância UV 254 nm. Para a quantificação e detecção dos analitos, ácidos 2,4-D, 2,4,5-T e o 2,4-DCP, foi desenvolvida e validada uma metodologia analítica em cromatografia líquida de alta eficiência (CLAE). Através dos dados de adsorção obtidos, o CAP 1 apresentou maior capacidade de remoção do 2,4-D e foi associado ao tratamento convencional, sendo adicionado quinze minutos antes, um minuto antes e um minuto após a adição do sulfato de alumínio. Os resultados indicaram que a adição do coagulante não influenciou na capacidade de adsorção do CAP 1 que apresentou-se eficiente na remoção do herbicida, atendendo ao padrão de potabilidade de água vigente / The 2,4-D is the second most widely used herbicide in Brazil, reaching the public water supply. Due to the limitation of conventional treatment in removing micro-contaminants and capacity of activated carbon to remove them, this study investigated the application of powdered activated carbon (PAC) in the removal of 2,4-D in adsorption process associated with conventional treatment using raw water from the Rio Santa Maria da Vitória in equipment jartest. The diagrams of coagulation were constructed through treatability study of water using aluminum sulfate and polyaluminum chloride as coagulants. Tests of adsorption with carbons derived from coconut shells (PAC 1) and pinus (PAC 2) were characterized and evaluated in its ability to remove 2,4-D. The removal of natural organic matter was also determined by measuring the dissolved organic carbon (DOC) and UV absorbance at 254 nm. To detection and quantification of analytes, acids 2,4-D, 2,4,5-T and 2,4-DCP an analytical methodology for high performance liquid chromatography (HPLC/DAD) was developed and validated. Through the adsorption data, the PAC 1 showed greater capacity for removal of 2,4-D and was associated with conventional treatment, fifteen minutes prior, one minute prior to or one minute after the addition of the aluminum sulfate. The results indicated that the addition of coagulant had no effect on adsorption capacity of the PAC 1 which showed to be being effective for the removal of herbicide, given the drinking water quality standards force
104

Reuso potável de esgoto sanitário: possibilidades e riscos / Potable reuse of wastewater: opportunities and risks

Carlos Custódio Santos de Rezende 15 October 2010 (has links)
O atual cenário de escassez hídrica enfrentada por certas regiões e o crescente grau de poluição dos recursos hídricos motivam pesquisas por alternativas para suprir esse déficit, uma vez que a água é um dos mais importantes recursos. Nesse cenário o reuso de água é uma importante e estratégica alternativa de instrumento de gestão de recursos hídricos, pois ao mesmo tempo em que reduz a pressão sob as fontes de água, também reduz significativamente os impactos gerados pelos lançamentos de esgotos em corpos receptores. Desse modo, o trabalho contemplou uma modalidade de reuso ainda não muito estudada, o reuso potável. Por ser uma modalidade que apresenta grandes riscos o trabalho se apoiou nos três aspectos principais associados: tecnologia, escassez e aceitação da população. O trabalho apresenta um estudo de caso para região metropolitana de Vitória, onde foi realizada uma projeção da demanda por recursos hídricos para curto (2015), médio (2020) e longo (2030) prazos, que quando comparada com a disponibilidade hídrica da região, concluiu que num futuro próximo (2015) a demanda será maior que a oferta. Para suprir esse déficit foi proposta uma alternativa de sistema de reuso potável indireto e feito uma avaliação da aceitação da população. / The current scenario of water scarcity faced by some regions and increasing degree of pollution of water resources motivate researches for alternatives to supply this deficit, since water is one of the most important resources. In this scenario, water reuse is an important and strategic alternative tool of water resources management, because while it reduces the pressure on water supplies, also significantly reduces the impacts caused by sewage discharge into receiving bodies of water. Thus, the work contemplated a form of reuse that is not so well studied, the potable reuse. Being a type that presents great risks, the work was supported in three main aspects associated with: technology, scarcity and public acceptance. The work presents a case study for the metropolitan region of Vitória, projected water demands for short (2015), medium (2020) and long (2030) terms, that when compared to water availability in the region, concluded that in the near future (2015) demand will be greater than the supply. To increase the disponibility of water was proposed an alternative system of indirect potable reuse and made an assessment of public acceptance.
105

Qualidade da Água Potável Consumida na Cidade do Salvador - Bahia

Duarte, Victor Magalhães 31 March 2010 (has links)
Submitted by Marcio Emanuel Paixão Santos (marcio.santos@ucsal.br) on 2018-06-21T17:02:54Z No. of bitstreams: 1 DISSERTACAOVICTORMAGALHAESDUARTE.pdf: 5911465 bytes, checksum: 6117af0ebbe7176d6a0b430080b16c8e (MD5) / Approved for entry into archive by Linda Bulhosa (linda.gomes@ucsal.br) on 2018-06-21T19:19:19Z (GMT) No. of bitstreams: 1 DISSERTACAOVICTORMAGALHAESDUARTE.pdf: 5911465 bytes, checksum: 6117af0ebbe7176d6a0b430080b16c8e (MD5) / Made available in DSpace on 2018-06-21T19:19:19Z (GMT). No. of bitstreams: 1 DISSERTACAOVICTORMAGALHAESDUARTE.pdf: 5911465 bytes, checksum: 6117af0ebbe7176d6a0b430080b16c8e (MD5) Previous issue date: 2010-03-31 / A pesquisa trata da qualidade da água potável consumida na cidade do Salvador, bem como apresenta as principais conseqüências para a saúde pela ingestão dos contaminantes que possam estar presentes na água potável e as medidas preventivas mais adequadas para removê-las. As contaminações que ocorrem nas fontes advêm do aumento da atividade industrial, do desenvolvimento de compostos agrícolas sintéticos, do despejo dos esgotos doméstico e industrial no meio ambiente sem o devido tratamento. A metodologia adotada incluiu análises da água potável consumida em Salvador, avaliação da legislação brasileira, sendo demonstrado que, mesmo quando são atendidos os parâmetros contidos na mesma, não pode ser garantida que a água potável não vá trazer sérios problemas para a saúde das pessoas a curto, médio e longo prazo. Os resultados demonstram que as pessoas avaliadas não possuem conhecimentos básicos necessários sobre os riscos dos contaminantes da água e o que fazer para minimizar as suas conseqüências. Mesmo sabendo que as concentrações dos contaminantes na água mudam muito de um dia para o outro, adotamos critérios científicos modernos ao serem avaliadas as análises de água fornecida pela empresa de saneamento da cidade, dos poços de água de uma empresa do Pólo Petroquímico de Camaçari e de amostras de água mineral encaminhadas a laboratórios especializados. Varias contaminantes da água foram mencionados e avaliados segundo critérios toxicológicos usando-se valores máximos fixados nas legislações do Brasil, Estados Unidos e Comunidade Européia (Organização Mundial de Saúde). Efeitos aditivos e sinergéticos dos contaminantes da água alem do fator denominado susceptibilidade individual foram citados como condições essenciais nas avaliações dos riscos reais das concentrações e das misturas dos contaminantes presentes na água potável consumida. Foram apresentadas técnicas de tratamento que possibilitam remover as impurezas orgânicas, inorgânicas, biológicas e radioativas da água potável, permitindo que as pessoas possam minimizar ao máximo os riscos de contaminação por via hídrica, conservando a saúde em elevados níveis. Foram ainda feitas sugestões que objetivam reduzir/eliminar as contaminações dos nossos mananciais de água potável, quer seja por ações federais, estaduais e municipais e da colaboração direta dos próprios cidadãos. Diante dos aspectos científicos abordados aqui, concluímos que tanto a água mineral quanto a água da rede de distribuída municipal não são isentas de riscos para consumo humano. / The research talks about the drinking water which is consumed in Salvador city and presents the main health consequences of the contaminants that can be found in the water and the prevention measurements more suitable to remove them. Contaminations which can be found in the water sources come from the growth industrial activities, synthetic agriculture compounds, domestic sewage and waste water that run-off without a proper treatment. The methodology used included drinking water analyzes consumed in Salvador city, an evaluation of Brazilian legislation, being demonstrated that, even when the legal parameters in the laws are fulfilled, it can not warranty that drinking this water will not produce serious health problems in the people in a short, medium and long period of time. The results show that people who were evaluated do not have enough basic knowledge about the risks of water contaminants and they do not know what to do to minimize their consequences. Even knowing that the concentration of the drinking water contaminants change a lot from one day to another, it was adopted modern scientific methodology when the water analyzes from the municipal water supply company were evaluated. The same methodology was adopted in the well water samples from a company in the Petrochemical Complex in Camaçari area and from mineral water samples which were sent to specialized laboratories. Many contaminants in the water were mentioned and evaluated under toxicological standards using maximum values established in the Brazilian, United States and European legislation (World Health Organization). Additive and synergetic effects of the drinking water contaminants besides the factor named individual susceptibility were cited as essential conditions in the real risk assessment of the contaminants concentration and mixtures of them present in the drinking water in study. It was presented point of use treatment techniques that make possible to remove organic, inorganic, biological and radioactive contaminants from drinking water. Doing that, people can minimize as much as possible the contamination risks from water sources, keeping the health in high levels. Yet it was done suggestions that aim to reduce or eliminate the contaminants of our drinking water sources, by federal, state and municipal actions and direct collaboration of the citizens themselves. In front of the scientific aspects mentioned here, we concluded that as much the mineral water as the municipal water from the distribution network are not free of risks to the human consumption.
106

Remoção de Microcystis Aeruginosa e Microcistina-LR por coagulação, floculação, sedimentação e filtração seguida de coluna de carvão ativado granular

Oliveira, Silvânia Nóbrega 30 October 2012 (has links)
Made available in DSpace on 2015-09-25T12:20:06Z (GMT). No. of bitstreams: 1 Silvania Nobrega Oliveira.pdf: 1403956 bytes, checksum: 0d02f35ffd2b6d222f655968bfdafe6e (MD5) Previous issue date: 2012-10-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The luxuriant proliferation of cyanobacteria in the water used as sources of drinking water is increasing around the world.The presence of these microorganisms in raw water can difficult the water treatment and make it more expensive. The main importance of health cyanobacterial bloom is the possible release of cyanotoxins in the water, which can cause serious risks to human health and unknown changes in aquatic biota. In the present study tests were carried out in a bench scale to evaluate the efficiency of removal of whole cells of Microcystis aeruginosa and the cyanotoxin microcystin-LR extracellular using coagulation, flocculation, sedimentation and filtration followed by a column of activated granular carbon produced in the northeast of Brazil. The water used was raw water from an eutrophic reservoir with addition of M. aeruginosa cells from a fresh culture maintained in laboratory conditions in order to obtain an initial concentration approximately with 105 cells.mL-1. The efficiency observed was up to 90% of cells removal using aluminum sulfate at the concentration of 45 mg.L-1 and a coagulation pH equal at 5.5 in the water decanted (with dosages of 40 and 60 mg.L-1 of the coagulant and pH equal at 7.5 the percentage of cells removal was 35%). The water effluent from the sand filter and the water effluent from the column of granular activated carbon had averages of M. aeruginosa cells equals to 3,8 and 3,6 log cel.mL-1 respectively. The average concentration of microcystin-LR in the water effluent from the GACC was 0,15 μg.L-1. Its value is below the limit of detection of the method (0,16 μg.L-1) and after 60 hours ranged from 0,18 to 0,28 μg.L-1. Both values were below the maximum allowed by ordinance 2914/11 Ministry of Health of 1 μg.L-1 microcystins in drinking water. / A proliferação luxuriante de cianobactérias na água dos mananciais usados como fontes de água potável é cada vez mais frequente. A presença desses microrganismos na água bruta pode dificultar e encarecer o tratamento, mas a principal importância sanitária do florescimento de cianobactérias é a possível liberação de cianotoxinas na água, que podem causar sérios agravos à saúde humana e alterações na biota aquática em geral. No presente trabalho foram realizados ensaios, em escala de bancada, de avaliação da eficiência de remoção de células inteiras de Microcystis aeruginosa e de uma de suas toxinas, microcistinaLR extracelular, por coagulação, floculação, sedimentação e filtração seguida de coluna de carvão ativado granular produzido na região nordeste utilizando-se água bruta de um manancial eutrofizado adicionada de células de M. aeruginosa cultivadas em laboratório para obter concentração inicial de aproximadamente 105 cel.mL-1. Observou-se eficiência de até 90% de remoção de células para dosagem superior a 45 mg.L-1 de sulfato de alumínio e pH de coagulação de 5,5 na água decantada (para dosagens de 40 e 60 mg.L-1 do coagulante e pH de 7,5 o percentual de remoção de células foi de 35%). Na água filtrada e na água efluente a coluna de carvão ativado granular, a concentração média de células de M. aeruginosa foi de 3,8 e 3,6 log cel.mL-1 respectivamente. A concentração media de MC-LR extracelular na água efluente da Coluna de Carvão Ativado Granular (CCAG) foi de 0,15 µg.L-1 abaixo do limite de detecção do método (0,16 µg.L-1) e após 60 horas variou de 0,18 a 0,28 µg.L-1 valores abaixo do valor máximo permitido pela portaria 2914/11 do Ministério da Saúde de 1 µg.L-1 de microcistinas na água de beber.
107

Registros históricos da implantação do sistema de abastecimento público de água no município de Taubaté 1850 A 1900.

Paulo Ernesto Marques Silva 14 February 2007 (has links)
This paper aims to discuss the public water system implantation in the Municipality of Taubaté during the last half of century XIX. There was a need for better life conditions concerning sanitation hygienic, due to the total lack of sanitary measures. The work also shows the solutions that were used to face the problems that where common to others cities in the Paraíba Valley and even in the Capital of the São Paulo State. It also describes the work developed by the Engineer Fernando de Mattos, who constituted the Companhia Norte de São Paulo that obtained from Taubaté Municipality Chamber the rights to explore the drinking water services in this region for 50 years and built up the system that was concluded in july 1893. / Neste trabalho é pesquisada a história da implantação do sistema de abastecimento público de água do município de Taubaté ocorrido em meados do século XIX. É descrita e analisada as péssimas condições de higiene nesta cidade durante este período, por ocasião da ausência total das condições sanitárias, causadas pela poluição das fontes de abastecimento de água, em torno das quais expandiram-se as construções formando o núcleo habitacional. Visando a solução do abastecimento de água para a população a Câmara analisou diversas alternativas. Por absoluta insuficiência de recursos a maioria delas foi descartada e a solução postergada pela Câmara de Taubaté. Finalmente em 1885 foi adotada a proposta do Engenheiro Fernando de Mattos que se dispôs a trazer água desde os contrafortes da Serra da Mantiqueira, por meio de uma canalização de ferro fundido, atravessando o Rio Paraíba do Sul, sua várzea, construindo um reservatório de acumulação e rede distribuidora na cidade. É mostrado o desenvolvimento de seu trabalho, que se inicia com a obtenção do privilégio da exploração dos serviços de abastecimento de água de Taubaté por 50 anos, a formação da Companhia Norte Paulista para este fim, até a conclusão dos serviços em julho de 1893.
108

Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable water

Meca, Karen Soraia 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
109

Identificação e verificação da resistência aos sanitizantes dos microrganismos presentes na água destinada ao abastecimento público e em um sistema de purificação / Identification and verification of resistance to the sanitizers of microorganisms present in the water for public supply and a purification system

Alzira Maria da Silva Martins 14 October 2002 (has links)
Água purificada para uso em ambientes de saúde e preparação industrial de produtos médico-odonto-hospitalar deve ter uma carga reduzida de contaminação microbiológica e pirogênio. As amostras analisadas foram coletadas em 13 (treze) diferentes estágios de um sistema de purificação de água, sendo isoladas 78 colônias. Para a identificação dos microrganismos foram utilizados: (i) identification system for non-enteric gram-negative rods (api 20 NE, bio Mérieux) e (ii) identification system for enteric and nonfermenter (BBL crystal, Becton Dickinson). De acordo com os resultados pode-se observar uma maior prevalência para Pseudomonas aeruginosa 32,05% (25 colônias dentre as 78 isoladas); Pseudomonas picketti 23,08% (18); Pseudomonas vesiculares 12,82% (10); Pseudomonas diminuta 11,54% (09); Flavobacterium aureum 6,42% (05); Pseudomonas fluorescences 5,13% (04); Acinetobacter Iwoffi 2,56% (02); Pseudomonas putida 2,56% (02); Pseudomonas alcaligenes 1,28% (01); Pseudomonas paucimobilis 1,28% (01), Flavobacterium multivorum 1,28% (01). A eficácia dos agentes sanitizantes utilizados para higienização dos diferentes pontos foi determinada pela concentração inibitória mínima (CIM) e tempo de redução decimal (valor D). Como o hipoclorito de sódio é largamente utilizado na higienização do tanque de água de alimentação, tanque de estocagem da água purificada e nas linhas de distribuição aos pontos de uso, este foi testado frente a todos os microrganismos sendo observado menor resistência para Escherichia coli ATCC 25922 (0.06%=600mg/L), quando comparada a P. aeruginosa isolada e identificada (O,25%=2500mg/L). O tempo de redução decimal (Valor D) da Escherichia coli ATCC 25922 foi de 4 minutos e o valor D da P. aeruginosa isolada e identificada e isolada in house foi de 9 minutos. / The samples of water, which were taken directly from the public distribution water tank and at twelve different stages of a typical purification system, were analyzed for the identification of isolated bacteria. The efficacy of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was valuated by the minimum inhibitory concentration (MIC and decimal reduction time (D-values). According to the miniature kits used in the identification, there was a prevalence of isolation by P. aeruginosa 32,05 % , P. picketti (Ralstonia picketti) 23,08%, P. vesiculares 12,82%, P. diminuta 11.54%, F.aureum 6,42%, P.fluorescens 5,13%, A.lowffi 2,56%, P.putida 2,56%, P. alcaligenes 1,28%, P.paucimobilis 1,28%, and F. multivorum 1,28%. The efficacy of the agents varied with the concentration and time of contact to reduce a decimal logarithmic (loglO) population (n cycles): (i) 0.5% citric acid (0= 4 min) for 30 min reduced n=7 cycles; (ii) 0.5% chloridric acid (0= 6 min) for 30 min reduced n= 4 cycles; (iii) 70% alcohol (0= 9 min) for 1.0 min (n=0.2 cycles); (iv) 0.5% sodium bisulphite (0= 6 min) for 90 min (n=14 cycles); (v) 0.4% sodium hydroxide (0= 8 min) for 30 min (n=3.0 cycles); (vi) 0.5% sodium hypochlorite (0=9 min) for 180 min (n = 19 cycles); (vii) mixture of hydrogen peroxide (2,2%) plus peracetic acid (0.45%), 0= 6 min, contact time of 180 min, reduced n = 32 cycles of the population. The sterility assurance level (SAL) of 10-6 was attained for the 0.5% sodium hypochlorite solution applied in the water purified storage tank and distribution loop; and for the mixture of H2O2 plus peracetic acid, used in the reverse osmose and in the deionizator systems.
110

Identificação e verificação da resistência aos sanitizantes dos microrganismos presentes na água destinada ao abastecimento público e em um sistema de purificação / Identification and verification of resistance to the sanitizers of microorganisms present in the water for public supply and a purification system

Martins, Alzira Maria da Silva 14 October 2002 (has links)
Água purificada para uso em ambientes de saúde e preparação industrial de produtos médico-odonto-hospitalar deve ter uma carga reduzida de contaminação microbiológica e pirogênio. As amostras analisadas foram coletadas em 13 (treze) diferentes estágios de um sistema de purificação de água, sendo isoladas 78 colônias. Para a identificação dos microrganismos foram utilizados: (i) identification system for non-enteric gram-negative rods (api 20 NE, bio Mérieux) e (ii) identification system for enteric and nonfermenter (BBL crystal, Becton Dickinson). De acordo com os resultados pode-se observar uma maior prevalência para Pseudomonas aeruginosa 32,05% (25 colônias dentre as 78 isoladas); Pseudomonas picketti 23,08% (18); Pseudomonas vesiculares 12,82% (10); Pseudomonas diminuta 11,54% (09); Flavobacterium aureum 6,42% (05); Pseudomonas fluorescences 5,13% (04); Acinetobacter Iwoffi 2,56% (02); Pseudomonas putida 2,56% (02); Pseudomonas alcaligenes 1,28% (01); Pseudomonas paucimobilis 1,28% (01), Flavobacterium multivorum 1,28% (01). A eficácia dos agentes sanitizantes utilizados para higienização dos diferentes pontos foi determinada pela concentração inibitória mínima (CIM) e tempo de redução decimal (valor D). Como o hipoclorito de sódio é largamente utilizado na higienização do tanque de água de alimentação, tanque de estocagem da água purificada e nas linhas de distribuição aos pontos de uso, este foi testado frente a todos os microrganismos sendo observado menor resistência para Escherichia coli ATCC 25922 (0.06%=600mg/L), quando comparada a P. aeruginosa isolada e identificada (O,25%=2500mg/L). O tempo de redução decimal (Valor D) da Escherichia coli ATCC 25922 foi de 4 minutos e o valor D da P. aeruginosa isolada e identificada e isolada in house foi de 9 minutos. / The samples of water, which were taken directly from the public distribution water tank and at twelve different stages of a typical purification system, were analyzed for the identification of isolated bacteria. The efficacy of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was valuated by the minimum inhibitory concentration (MIC and decimal reduction time (D-values). According to the miniature kits used in the identification, there was a prevalence of isolation by P. aeruginosa 32,05 % , P. picketti (Ralstonia picketti) 23,08%, P. vesiculares 12,82%, P. diminuta 11.54%, F.aureum 6,42%, P.fluorescens 5,13%, A.lowffi 2,56%, P.putida 2,56%, P. alcaligenes 1,28%, P.paucimobilis 1,28%, and F. multivorum 1,28%. The efficacy of the agents varied with the concentration and time of contact to reduce a decimal logarithmic (loglO) population (n cycles): (i) 0.5% citric acid (0= 4 min) for 30 min reduced n=7 cycles; (ii) 0.5% chloridric acid (0= 6 min) for 30 min reduced n= 4 cycles; (iii) 70% alcohol (0= 9 min) for 1.0 min (n=0.2 cycles); (iv) 0.5% sodium bisulphite (0= 6 min) for 90 min (n=14 cycles); (v) 0.4% sodium hydroxide (0= 8 min) for 30 min (n=3.0 cycles); (vi) 0.5% sodium hypochlorite (0=9 min) for 180 min (n = 19 cycles); (vii) mixture of hydrogen peroxide (2,2%) plus peracetic acid (0.45%), 0= 6 min, contact time of 180 min, reduced n = 32 cycles of the population. The sterility assurance level (SAL) of 10-6 was attained for the 0.5% sodium hypochlorite solution applied in the water purified storage tank and distribution loop; and for the mixture of H2O2 plus peracetic acid, used in the reverse osmose and in the deionizator systems.

Page generated in 0.0447 seconds