Spelling suggestions: "subject:"fré - concentração"" "subject:"cré - concentração""
21 |
Desenvolvimento de método de pré-concentração empregando 1-(2-piridilazo)-2-naftol imobilizado em sílica funcionalizada C18 para determinação de metais em águas naturais por ICP OESCarvalho, Roberta Natália Carneiro da Silva 05 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-09-17T17:51:04Z
No. of bitstreams: 1
(Dissertação_mestrado__(03.11_)).pdf: 1756144 bytes, checksum: 6a5c8a2f486f154eba91b5aa9780dde0 (MD5) / Approved for entry into archive by Fatima Cleômenis Botelho Maria (botelho@ufba.br) on 2014-09-19T12:24:04Z (GMT) No. of bitstreams: 1
(Dissertação_mestrado__(03.11_)).pdf: 1756144 bytes, checksum: 6a5c8a2f486f154eba91b5aa9780dde0 (MD5) / Made available in DSpace on 2014-09-19T12:24:04Z (GMT). No. of bitstreams: 1
(Dissertação_mestrado__(03.11_)).pdf: 1756144 bytes, checksum: 6a5c8a2f486f154eba91b5aa9780dde0 (MD5) / CNPQ / A determinação de metais em águas naturais por Espectrometria de Emissão Óptica com
Plasma Indutivamente Acoplado (ICP OES), em geral, deve envolver etapas de pré-
concentração, devido os níveis de concentração dos metais em água serem muitas vezes
abaixo dos limites de detecção da técnica. Dessa forma, o objetivo desse trabalho foi
desenvolver um método de pré-concentração em fase sólida sensível e simples para a
determinação de cobre, ferro, níquel, manganês, chumbo e zinco em amostras de água por
ICP OES. As condições experimentais para pré-concentração foram otimizadas
considerando os fatores: concentração do eluente, volume de eluente, volume da amostra,
vazão e pH. As condições otimizadas corresponderam ao uso de 5 mL de solução de HCl
0,8 mol L-1 como eluente, volume da amostra de 50 mL, vazão de 1,9 mL min-1 e pH 9,0.
Para a determinação dos metais, as amostras, após ajuste do pH, foram percoladas com o
auxílio de uma bomba peristáltica em cartucho Sep-pak C18 com 1-(2-piridilazo)-2-naftol
(PAN) imobilizado na sílica funcionalizada C18. A eluição dos analitos foi realizada com a
passagem da solução de HCl pelo cartucho para posterior determinação por ICP OES.
Nestas condições, os limites de detecção para Cu, Fe, Mn, Ni, Pb e Zn obtidos variaram
entre 0,11 e 21 µg L-1 e os limites de quantificação entre 0,36-69 µg L-1, respectivamente. Os
desvios padrão relativos (R.S.D.) para a determinação dos analitos não ultrapassaram 9 %.
O efeito de possíveis espécies interferentes sobre a recuperação dos analitos também foram
investigados. A exatidão do método foi avaliada mediante análise de material de referência
certificado (SLEW-3 Estuariene Water Reference Material for Trace Metals) e o método
proposto foi aplicado para análise de amostras de água subterrânea, água potável e água
de rio coletadas nos municípios de Cachoeira e São Félix, Bahia, Brasil. As amostras foram
analisadas por Espectrometria de Massas com Plasma Indutivamente Acoplado (ICP-MS)
como método comparativo, não sendo observadas diferenças significativas entre estes resultados e os resultados obtidos pelo método proposto. / The determination of metals in natural waters by Inductively Coupled Plasma Optical
Emission Spectrometry (ICP OES), in general, involves pre-concentration steps, due the
concentration levels of metals in water are often below the limits of detection of this
technique. In this way, the objective of this work was to develop a pre-concentration solid
phase method for sensitive and simple determination of copper, iron, nickel, manganese,
lead and zinc in water samples by ICP OES. The experimental conditions for pre-
concentration were optimized considering the following factors: the concentration of the
eluent, eluent volume, sample volume, flow-rate and pH. The optimized conditions
corresponded to the use of 5 mL of HCl solution 0.8 mol L-1 as an eluent sample volume 50
ml, flow-rate 1.9 mL min-1 and pH 9.0. For the determination of metals by the procedure, the
samples after pH adjustment were percolated with the aid of a peristaltic pump on Sep-Pak
C18 cartridge with 1-(2-pyridylazo)-2-naphthol (PAN). The analyte elution was carried out
with the passage of the HCl solution in the cartridge for subsequent determination by ICP
OES. In these conditions, the detection limit for Cu, Fe, Mn, Ni, Pb and Zn varied between
0.11 to 21 μg L-1 and the limits of quantification from 0.36 to 69 μg L-1, respectively. The
relative standard deviation (RSD) for the analytes of this study did not exceed 9%. The effect
of possible interfering species on the recovery of the analytes was also investigated. The
accuracy of the method was evaluated by analysis of certified reference material (SLEW-3
Estuariene Water Reference Material for Trace Metals) and the proposed method was
applied to samples of ground water, drinking water and river water collected in Cachoeira
and São Félix cities, Bahia, Brazil. The samples were analyzed by Inductively Coupled
Plasma Mass Spectrometry (ICP-MS) as a comparative method do not being found
significant differences among these results and the results obtained by the proposed method.
|
22 |
Desenvolvimento de estratégias de pré-concentração para eletroforese capilar (CE) visando a análise de pesticidas em frutas e leguminosas / Development of preconcentration strategies for pesticides analysis by capillary electrophoresis (CE) in fruits and tubersClóvis Lúcio da Silva 30 April 2003 (has links)
O uso de pesticidas constitui um importante aspecto na agricultura moderna, com inquestionável beneficio na produção agrícola. Porém a contaminação dos alimentos por pesticidas constitui um sério risco a saúde do consumidor. A determinação de resíduo de pesticidas em alimentos envolve procedimentos laboriosos, com elevado tempo de análise e várias etapas de pré-concentração. Neste trabalho, procedimentos alternativos de extração e pré-concentração para analise multiresíduo de pesticida em água, frutas e tubérculos foram desenvolvidos. A eletroforese capilar em seu modo MEKC em condições de alto e baixo fluxo eletrosmótico foi empregado para a otimização da separação de diferentes classes de pesticidas (triazinas, organofosforado, carbendamidazóis, feniluréia e carbamatos). A composição do eletrólito de separação otimizada para condições de alto EOF foi: 10 mmol L-1 de tetraborato de sódio (pH 9,3),50 mmol L-1 de SDS e 5% etanol e 5% propanol, enquanto que para condições de baixo EOF foi: 10 mmol L-1 de tampão fosfato (pH 2,5), 25 mmol L-1 de SDS e 10% metanol. Estratégias de pré-concetração on-line conhecida como sweeping (SW) e stacking nos modos de migração reversa das micelas (SRMM) e migração reversa com um plug de água (SWR) bem como as suas versões modificadas foram avaliadas, obtendo fatores de pré-concetração de variaram de 2,6 a 19 para o SW, 2,9 a 15 para o SRW e de 5,5 a 15 para o método SRMM modificado. Varias metodologias de extração envolvendo extração em fase sólida (SPE) e extração líquido-líquido (LLE) foram testada. A estratégia de extração por cloud point foi aplicada a uma amostra de abacaxi. O procedimento denominado dispersão da matriz em fase sólida (sigla inglesa MSPD), que minimiza o uso de solventes orgânicos e é de fácil implementação foi aplicado a amostras de cenoura. A combinação do SPE off-line e das estratégias de pré-concentração anteriormente mencionadas permitiram a determinação de alguns pesticidas na concentração de 0,1 µg L-1 em amostras de água potável. O método de extração e clean-up MSPD seguida da análise de MEKC em alto EOF foi otimizado e algumas figuras de mérito foram estabelecidas baseados em protocolos de validação para análise de pesticidas (IAEA-FAO). Boa linearidade (r > 0,99) foi obtido para todos os pesticidas estudados, exceto para linuron e dimetoato. A precisão do método foi estimada através de testes de recuperação. Dois níveis de fortificação foram utilizados para a avaliação, foram obtidos recuperações de 51 a 89 % para o nível mais baixo e 67 a 100% para o maior nível. Foi obtida uma boa precisão intraensaio (CV < 15%). O método otimizado foi aplicado para análise multiresíduo de cenouras. Uma amostra adquirida no comércio local foi quantificada encontrando-se 0,88 mg kg-1 de simazina, 0,13 mg kg-1 de atrazina e 0,08 mg kg-1 de propazina. / The use of pesticides constitutes an important aspect of modem agriculture, with unquestionable impact on crop production. However, food contamination by pesticide residues is a serious risk for the consumer. The determination of pesticide residues in food usually involves laborious procedures, with time consuming sample clean up and preconcentration steps prior to the analysis. In this work, alternative methodologies for extraction, pre-concentration and analysis of pesticide multi-residue in water, fruits and tubers were developed. Capillary electrophoresis in its micellar mode (micellar electrokinetic Chromatography, MEKC) under low and high electroosmotic flow (EOF) conditions was used for the separation of pesticides from different chemical classes (triazines, organophosphorous, carbendamidazols, phenilurea and carbamates). Optimized electrolyte compositions were: high EOF - 10 mmol L-1 tetraborate (pH 9.3), 50 mmol L-1 SDS, 5 % ethanol and 5 % propanol; low EOF - 10 mmol L-1 phosphate buffer (pH 2.5), 25 mmol L-1 SDS and 10 % methanol. On-line preconcentration strategies for MEKC known as sweeping (SW) and stacking with reverse migrating micelles with (SRW) and without (SRMM) a plug of water prior to the sample plug as well as modified versions of SRW and RMM were evaluated and contrasted in terms of signal enhancement factor (peak height ratios) Signal enhancement factors for SW varied from 2,6 to 19 for SRW from 2,9 to 15, whereas for modified-SRMM from 5,5 to 15. Among the extraction methodologies, several procedures involving solid-phase extraction (SPE) and liquid-liquid extraction (LLE) were tested. It is worth mentioning a strategy based upon cloud point extraction, which was applied to pineapple samples and a procedure denominated matrix solid-phase dispersion (MSPD), which combines low cost, saves in solvents and easy implementation, applied to carrots. The combination of off-line SPE and the above mentioned on-line preconcentration strategies allowed the determination of selected pesticides in the 0.1 µ/L level (drinking water sample). A complete methodology involving MSPD for extraction and sample clean-up followed by MEKC in high EOF was optimized and a few figures of merit were established based on method validation protocols for pesticide analysis (IAEA-FAO). Good linearity (r>0.99) was obtained for all pesticides under investigation, except for linuron and dimetoate. The method accuracy was estimated by recovery tests. Two level standard spiking were conducted with recoveries of 51 to 89 % for the lowest level and 67 to 100 % for the highest level. Acceptable intra-day precision was obtained (CV < 15 %). The optimized method was applied to the analysis of multi-residue pesticides in carrots. In a sample acquired in a local grocery store an unusual amount of triazines was found: simazine (O,88 mg/kg), atrazine (0,13 mg/kg) and propazine (0,088mg/kg).
|
23 |
Determinação de íons metálicos por FI-FAAS após separação e concentração em fase sólida: avaliação crítica de adsorventes / Determination of metallic ions by FI-FAAS after separation and preconcentration in solid-phase: critical evaluation of adsorbentsGrazielle de Campos Anaia 29 February 2008 (has links)
Um procedimento de separação e pré-concentração em sistemas de análises em fluxo acoplado a espectrometria de absorção atômica com atomização em chama (FI-FAAS) é proposto para a determinação de Cu(II), Ni(II) e Cd(II). Diferentes adsorventes (XAD-7, sílica-gel e sílica funcionalizada C18) foram avaliados para a imobilização do reagente 1-(2-tiazolilazo)-2-naftol (TAN) que forma complexos com diversos íons metálicos. A avaliação e seleção do adsorvente baseou-se em isotermas de adsorção (Langmuir, Freundlich e Dubinin- Radushkevich (D-R)) e estudos de dessorção. O modelo de Langmuir indicou que a -2 -1 sílica-gel adsorve uma quantidade maior de TAN (1,81±0,08)x10-2 g g-1 em relação à XAD-7 (4,05±0,51)x10-3 g g-1 e à sílica funcionalizada C18 1,58x10-2 g g-1 . Pelo modelo de Freundlich, foi verificado que a superfície da XAD-7 apresenta elevada heterogeneidade energética dos sítios de adsorção evidenciado pelo parâmetro n de 2,57±0,08 contra 1,01±0,02 para sílica-gel. A constante de Freundlich foi de -1 (0,232±0,023) e (2,27±0,59) g g-1 para XAD-7 e sílica-gel, respectivamente. O modelo de D-R revelou que ocorre fisissorção para ambos os adsorventes. Estudos de dessorção permitiram concluir que a XAD-7 modificada apresentou a menor massa de TAN dessorvida em comparação com a sílica-gel, nas condições de acidez a serem empregadas nas etapas de retenção e eluição dos íons metálicos. Desta forma, XAD-7 imobilizada com o TAN foi selecionada para pré-concentração dos metais no sistema de análises em fluxo. Utilizando um amostrador temporizado eletronicamente, as variáveis vazão e concentração do eluente, pH de retenção, vazão e tempo de pré-concentração da amostra foram avaliadas. Na etapa de amostragem, os íons metálicos foram pré-concentrados por 300 s na forma de complexos com o TAN, empregando vazão de amostra de 6,2 mL min-1 e pH 7,5. A eluição foi efetuada com 0,2 mol L-1 HNO3 e vazão de 6,2 mL min-1 . O limite de detecção e o fator de enriquecimento foram estimados em 0,20 µg L-1 e 68; 1,5 µg L-1 e 15 e 0,060 µg L-1 e 44 para Cu(II), Ni(II) e Cd(II), respectivamente. Os coeficientes de variação foram estimados em 3,2%, 5,6% e 3,6% para Cu(II), Ni(II) e Cd(II), respectivamente. O procedimento proposto para FI não é adequado para a pré-concentração de metais em amostras contendo altas concentrações de íons cloreto, devido à formação de cloro-complexos, que prejudicam a formação de complexos com TAN na fase sólida. / A flow-based procedure for separation and preconcentration coupled to flame atomic absorption spectrometry (FI-FAAS) is proposed for determination of Cu(II), Ni(II) e Cd(II). Different sorbents (XAD-7, silica gel and C18 bonded silica) were evaluated for the immobilization of the reagent 1-(2-thiazolylazo)-2-naphthol (TAN), which reacts with several metal ions yielding complexes. The evaluation and selection of the adsorbent was based on adsorption isotherms (Langmuir, Freundlich and Dubinin-Radushkevich (D-R)) as well as desorption studies. The Langmuir model indicated that silica gel uptakes higher amount of TAN (1.81±0.08)x10-2 g g-1 as compared to (4.05±0.51)x10-3 g g-1 for XAD-7 and (1.58x10-2 ) g g-1 for C18 bonded silica. Based on the Freundlich model, it was verified that XAD-7 surface presented high energetic heterogeneity of the adsorption sites evidenced by the parameter n of 2.57±0.08 against 1.01±0.02 to silica gel. The Freundlich constant was 0.232±0.023 -1 and 2.27±0.59 g g-1 for XAD-7 and silica gel, respectively. The D-R model revealed that physical sorption occurred for both adsorbents. The modified XAD-7 showed the lowest desorbed mass in comparison to silica gel, in the same acidity conditions employed for retention and eluting steps of the metal ions. XAD-7 modified with TAN was thus selected to concentrate metal ions in the flow system. Using a time-based sample loading, the variables like eluent flow rate and concentration; pH in the retention step, sample flow rate and loading sample time were investigated. In the sampling step, the metal ions were preconcentrated for 300 s in the form of TAN complexes, employing a sample flow rate of 6.2 mL min-1 and pH 7.5. The elution was carried out with 0.2 mol L-1 HNO3 and flow rate of 6.2 mL min-1 . The detection limits and enrichment factors were estimated as 0.2 µg L-1 and 68; 1.5 µg L-1 and 15 and 0.060 µg L-1 and 44 for Cu(II), Ni(II) and Cd(II), respectively. The coefficients of variation were estimated as 3.2%, 5.6% and 3.6% for Cu(II), Ni(II) and Cd(II), respectively. The proposed procedure is not appropriate for the preconcentration of metals in samples containing high chlorides concentrations due to the formation of chloride-complexes that hinder the formation of the TAN-complexes on the solid phase.
|
24 |
Avaliação da resina quelante chelex-100® na pré-concentração e da espectrometria de absorção atômica de alta resolução com fonte contínua e forno de grafite para a determinação de metais-traço em água produzida de alta salinidadeFreire, Aline Soares 14 April 2016 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2016-04-14T16:10:05Z
No. of bitstreams: 1
Dissertação - Aline Soares Freire - FINAL.pdf: 4503064 bytes, checksum: 1e469a75225eda50cf3c49c6ab32c87a (MD5) / Made available in DSpace on 2016-04-14T16:10:05Z (GMT). No. of bitstreams: 1
Dissertação - Aline Soares Freire - FINAL.pdf: 4503064 bytes, checksum: 1e469a75225eda50cf3c49c6ab32c87a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geociências-Geoquímica. Niterói, RJ / A análise de amostras hipersalinas ainda é um problema analítico a ser resolvido,
tendo em vista que a presença de sais dissolvidos é fonte freqüente de
interferências em espectrometria atômica. Atualmente, tem ocorrido um grande
aumento da demanda para caracterização de águas de alta salinidade, como as
águas produzidas, pelo fato de estas serem um dos maiores descartes da indústria
de petróleo. Devido a isto, metodologias analíticas para sua caracterização têm sido
amplamente desenvolvidas para a determinação de metais-traço em amostras
salinas e dentre as técnicas analíticas destaca-se a Espectrometria de Absorção
Atômica de Alta Resolução com Fonte Contínua, uma renovação da AAS
convencional. Contudo, para a obtenção de resultados acurados, é imprescindível
que se faça a remoção dos sais presentes nessas matrizes hipersalinas. Essa
separação prévia pode ser realizada através do emprego de resinas qualantes, que
pré-concentram o analito e permitem a remoção da matriz. Sendo assim, este
trabalho visa à avaliação do uso da resina quelante comercial Chelex-100® na préconcentração
de Co, Cu, Mn, Ni e Pb e posterior determinação destes por
Espectrometria de Absorção Atômica de Alta Resolução com Fonte Contínua e
Forno de Grafite (HR-CS GF AAS). A metodologia foi validada através do uso dos
materiais de referência certificados para água do mar CASS-4, CASS-5 e NASS-5.
Os limites de detecção obtidos, em μg L-1, foram de 0,006; 0,070; 0,024; 0,074; e
0,018 para Co, Cu, Mn, Ni e Pb, respectivamente. Amostras de água produzida
oriundas de plataformas de petróleo offshore foram analisadas e os resultados
mostraram que essas águas possuem baixas concentrações dos elementos
determinados ou os mesmos não foram detectados. Os valores encontrados são
muito inferiores aos limites preconizados pela legislação brasileira através da
Resolução CONAMA 357/05 / The analysis of hypersaline samples is still an analytical problem to be solved, once
the presence of dissolved salts is a frequent source of interferences in atomic
spectrometry. Actually, there is a large increase in the interest in the caracterization
of this kind of sample, as produced waters are one of the largest discharges of
petroleum industry. Hence, analytical methodologies to produced water
caracterization have been widely developed to trace metals determination in saline
samples and among the analytical techniques, there is High Resolution Continuum
Source Atomic Absorption Spectrometry, a renovation of conventional AAS.
However, to obtain accurated results, it's necessary to remove the salts present in
this high salinity matrices. This previous separation can be done employing a
chelating resin, that preconcentrates the analyte(s) and allows matrix removal. In this
way, the aim this work is to evaluate the use of chelating resin Chelex-100® to
preconcentrate Co, Cu, Mn, Ni and Pb, for the later determination by High Resolution
Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GF
AAS). The methodology was validated by the use of sewater certified reference
materials CASS-4, CASS-5 e NASS-5. The detection limits in μg L-1, were 0,006;
0,070; 0,024; 0,074; and 0,018 for Co, Cu, Mn, Ni and Pb, respectively. Produced
water samples from offshore petroleum platforms were analysed and results showed
that this waters have low concentrations of these studied elements or could not be
detected. Found values are much lower when compared to limits from Brazilian
legislation, in this case CONAMA 357/05 Resolution
|
25 |
Separação e pré-concentração de metais : uma transferência do meio aquoso para fase sólida ou líquidos orgânicosSouza, Rodrigo Papai de January 2018 (has links)
Orientadora: Profa. Dra. Ivanise Gaubeur / Tese (doutorado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência e Tecnologia/Química, Santo André, 2018. / Dois novos procedimentos de extração que utilizam materiais
extratores não-convencionais são apresentados nesta tese. A utilização de
cera de parafina derretida como um extrator químico permitiu agregar as
principais vantagens da extração em fase líquida (homogeneidade do extrato,
curto tempo de extração e simplicidade de operação) na extração em fase
sólida, delineando um procedimento inovador. O papel matte foi outro
material estudado nesse trabalho e mostrou-se interessante como extrator
químico, especialmente pelo baixo custo dessa fase sólida. Como prova de
conceito, o íon metálico cobre (II) em solução aquosa foi utilizado para o
desenvolvimento da metodologia. O extrato resultante de ambos os
procedimentos de extração foi analisado diretamente por Espectrometria de
Emissão Óptica com Plasma Induzido por LASER (LIBS). Os fatores que
afetam a reação de complexação, a extração e a detecção do analito na fase
sólida foram otimizados num estudo univariado. Nas melhores condições
encontradas, foram construídas curvas de calibração numa faixa linear de
0,50 até 10,00 mg L-1 e alcançados limites inferiores de detecção de 0,12 mg
L-1 e 0,08 mg L-1 de cobre (II) em solução aquosa, para os procedimentos com
cera de parafina e com o papel matte, respectivamente. A precisão de ambos
os métodos propostos mostrou-se inferior a 5% e a exatidão foi avaliada por:
(i) análise de material de referência certificado de soro sanguíneo humano;
(ii) ensaios de adição e recuperação do analito em amostras líquidas de
composição química distintas (água mineral, água do mar, água de torneira,
cachaça, refrigerante e urina humana) e (iii) comparação dos resultados
obtidos com os fornecidos pelo método de Espectrometria de Absorção
Atômica com Forno de Grafite. Ambos os procedimentos se destacaram pela:
(i) elevada eficiência no processo de extração (>94%); (ii) facilidade de
execução; (iii) baixo custo e inocuidade dos extratores; (iv)
microhomogeneidade das fases sólidas obtidas; (v) possibilidade de préconcentração
de íons metálicos e (vi) superação das dificuldades intrínsecas
na análise de líquido por LIBS. / Two new extraction procedures that use non-conventional extractant
materials are described in this thesis. The use of melted paraffin wax as a
chemical extractant allowed to aggregate the main advantages of the liquid
phase extraction (homogeneity of the extract, short extraction time and
simplicity of operation) in solid phase extraction, delineating an innovative
procedure. The matte paper was another material studied in this work and
was interesting as a chemical extractant, especially for the low cost of this
solid phase. As proof of concept, the copper (II) ion in aqueous solution was
applied for the development of the methodology. The extract obtained from
both extraction procedures was analyzed directly by LASER-Induced
Breakdown Spectroscopy (LIBS). The parameters that affecting the
complexation reaction, extraction and analyte detection in the solid phase
were optimized in a univariate approach. Under the best conditions,
calibration curves were constructed in a linear range of 0.50 to 10.00 mg L-1
and lower detection limits of 0.12 mg L-1 and 0.08 mg L-1 of copper (II) in
aqueous solution were obtained, for the procedures with paraffin wax and
matte paper, respectively. The precision of both methods was less than 5%
and accuracy was assessed by: (i) analysis of certified reference material of
human blood serum; (ii) spike and recovery analyte in liquid samples of
different chemical compositions (seawater, tap water, mineral water,
cachaça, soft drink and human urine) and (iii) comparison of the results
obtained with those provided by the Graphite Furnace Atomic Absorption
Spectrometry. Both procedures were highlighted by: (i) high efficiency in the
extraction process (> 94%); (ii) ease of execution; (iii) low cost and safety of
extractants; (iv) microhomogeneity of the solid phases obtained; (v) the ability
of preconcentration metal ions and (vi) overcoming the intrinsic drawbacks
in liquid analysis by LIBS.
|
26 |
Comparação das metodologias de extração no ponto nuvem e extração em fase sólida para a determinação de cádmio em amostras de águas / Comparison of methodologies for cloud point extraction and solid phase extraction for determination of cadmium in water samplesJéssica Correia Ramella 23 October 2009 (has links)
Apresenta-se a comparação de duas metodologias para pré-concentração e determinação de Cd em amostras de águas estuarinas e água de mar. As metodologias comparadas foram a extração líquido-líquido no ponto nuvem e a extração por retenção dos analitos em fase sólida. Em ambos os métodos houve necessidade de formação de complexos de Cd previamente à extração. Dois agentes complexantes foram testados o O-O dietilditiofosfato (DDTP), e 1-(2- tiazolilazo)-2-naftol (TAN). A extração no ponto nuvem foi realizada utilizando o surfactante não iônico octil fenoxipolietoxietanol (Triton X-114) que à temperatura de \'40 graus\'C forma uma fase micelar viscosa de volume reduzido. Após separação das micelas, estas foram dissolvidas em solução de ácido nítrico facilitando a análise por ICP OES. A pré-concentração em fase sólida por retenção dos íons complexados foi realizada colocando-se uma coluna de Amberlite XAD 4 em sistema em fluxo. Foram ajustadas as vazões de carregamento da coluna e eluição de forma a aumentar os fatores de pré-concentração. Os volumes das soluções finais foram de 2 mL de forma a obter resultados em triplicata na análise por ICP OES. A quantificação foi efetuada pelo método das adições de padrão. Os dois procedimentos foram comparados considerando as eficiências relativas de pré-concentração, a facilidade para efetuar os procedimentos e a percentagem de recuperação das medidas / Two methodologies for determination of Cd in estuarine and seawater samples were studied. The methodologies for pre-concentration of analytes by surfactant-mediated cloud point extraction and solid phase retention in a resin column were compared. In both cases the prior formation of Cd ions complexes with O,O-diethyldithiophosphate (DDTP) and 1-(2-thiazolylazo)-2-naphtol (TAN) was carried out. The Cloud point extraction was attained with the non ionic surfactant ctylphenoxypolyethoxyethanol (Triton X-114) at \'40 graus\'C . The reduced volume of surfactant micelles was easily separated and dissolved using the solution containing nitric acid which facilitate the analysis by ICP OES. The solid phase pre-concentration was performed by retention of the complexed ions in the Amberlite XAD 4 resin column in a flow scheme. The flow-rates for sample loading and elution were adjusted to increase the preconcentration factor. The final volumes collected of 2 mL were further analyzed in triplicate by ICP OES. Quantification was performed by the standard addition method. Both pre-concentration procedures were compared considering the relative efficiencies, the complexity of procedures and recovery percent of results
|
27 |
Comparação das metodologias de extração no ponto nuvem e extração em fase sólida para a determinação de cádmio em amostras de águas / Comparison of methodologies for cloud point extraction and solid phase extraction for determination of cadmium in water samplesRamella, Jéssica Correia 23 October 2009 (has links)
Apresenta-se a comparação de duas metodologias para pré-concentração e determinação de Cd em amostras de águas estuarinas e água de mar. As metodologias comparadas foram a extração líquido-líquido no ponto nuvem e a extração por retenção dos analitos em fase sólida. Em ambos os métodos houve necessidade de formação de complexos de Cd previamente à extração. Dois agentes complexantes foram testados o O-O dietilditiofosfato (DDTP), e 1-(2- tiazolilazo)-2-naftol (TAN). A extração no ponto nuvem foi realizada utilizando o surfactante não iônico octil fenoxipolietoxietanol (Triton X-114) que à temperatura de \'40 graus\'C forma uma fase micelar viscosa de volume reduzido. Após separação das micelas, estas foram dissolvidas em solução de ácido nítrico facilitando a análise por ICP OES. A pré-concentração em fase sólida por retenção dos íons complexados foi realizada colocando-se uma coluna de Amberlite XAD 4 em sistema em fluxo. Foram ajustadas as vazões de carregamento da coluna e eluição de forma a aumentar os fatores de pré-concentração. Os volumes das soluções finais foram de 2 mL de forma a obter resultados em triplicata na análise por ICP OES. A quantificação foi efetuada pelo método das adições de padrão. Os dois procedimentos foram comparados considerando as eficiências relativas de pré-concentração, a facilidade para efetuar os procedimentos e a percentagem de recuperação das medidas / Two methodologies for determination of Cd in estuarine and seawater samples were studied. The methodologies for pre-concentration of analytes by surfactant-mediated cloud point extraction and solid phase retention in a resin column were compared. In both cases the prior formation of Cd ions complexes with O,O-diethyldithiophosphate (DDTP) and 1-(2-thiazolylazo)-2-naphtol (TAN) was carried out. The Cloud point extraction was attained with the non ionic surfactant ctylphenoxypolyethoxyethanol (Triton X-114) at \'40 graus\'C . The reduced volume of surfactant micelles was easily separated and dissolved using the solution containing nitric acid which facilitate the analysis by ICP OES. The solid phase pre-concentration was performed by retention of the complexed ions in the Amberlite XAD 4 resin column in a flow scheme. The flow-rates for sample loading and elution were adjusted to increase the preconcentration factor. The final volumes collected of 2 mL were further analyzed in triplicate by ICP OES. Quantification was performed by the standard addition method. Both pre-concentration procedures were compared considering the relative efficiencies, the complexity of procedures and recovery percent of results
|
28 |
Síntese e aplicação de sílica modificada na adsorção de Cu(II), Cd(II) e As(V) em meio aquoso: pré-concentração em amostras de águas naturais / Synthesis and application of modified silica in Cu (II), Cd (II) and As (V) adsorption in aqueous media: preconcentration in natural water samples.Wondracek, Marcos Henrique Pereira [UNESP] 05 October 2017 (has links)
Submitted by MARCOS HENRIQUE PEREIRA WONDRACEK null (marcoswondracek@ufgd.edu.br) on 2017-10-29T05:42:20Z
No. of bitstreams: 1
TESE - versão final.pdf: 3488966 bytes, checksum: 44030b3422f6b77b9ba441eb0905cb23 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-11-09T13:58:32Z (GMT) No. of bitstreams: 1
wondracek_mhp_dr_araiq.pdf: 3488966 bytes, checksum: 44030b3422f6b77b9ba441eb0905cb23 (MD5) / Made available in DSpace on 2017-11-09T13:58:32Z (GMT). No. of bitstreams: 1
wondracek_mhp_dr_araiq.pdf: 3488966 bytes, checksum: 44030b3422f6b77b9ba441eb0905cb23 (MD5)
Previous issue date: 2017-10-05 / Item merged in doublecheck by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-12-07T17:59:08Z
Item was identical to item(s): 153113, 153193 at handle(s): http://hdl.handle.net/11449/152063, http://hdl.handle.net/11449/152164 / Este trabalho relata o desenvolvido de métodos analíticos que visa à determinação de algumas espécies tóxicas e potencialmente tóxicas de metais e metalóides em níveis ultra-traço em amostra de água naturais, utilizando uma técnica analítica menos sensível, como a espectrometria de absorção atômica em chama (FAAS). Essa técnica foi escolhida por ser relativamente simples e possuir baixo custo operacional. A técnica de extração em fase sólida (EFS), utilizando um novo material sorvente, foi utilizada para separar e pré-concentrar os analitos. Este estudo demonstra o procedimento de uma nova rota sintética via co-condensação visando à produção de uma sílica mesoporosa organofuncionalizada com o ligante 4-amino-3-hidrazino-5-mercapto-1,2,4-triazole e, sua utilização como sorvente para pré-concentração/análise de especiação de íons metálicos em amostras de água. O material produzido foi caracterizado por espectroscopia na região do infravermelho (FTIR), BET, ressonância magnética nuclear (RMN) de 29Si e 13C, dentre outras. As características adsortivas desse material foram estabelecidas em estudos de batelada, onde se estudou o efeito do pH, cinética de adsorção e capacidade máxima de adsorção. A otimização multivariada foi utilizada para obtenção das melhores condições químicas e de fluxo no sistema de pré-concentração, permitindo avaliar as interações principais e secundárias entre os fatores. Por meio da análise dos espectros obtidos por FTIR foi possível observar bandas de estiramento C–H, C–Cl e (NH2) oriundos da fração orgânica do material. A área superficial foi de 369,84 m2 g-1com diâmetro médio de poros em 7,1 nm, relacionados a materiais mesoporosos. Os resultados obtidos por RMN de 29Si comprovam a formação do material híbrido, sintetizado por co-condensação, e o RMN de 13C confirma o ancoramento do ligante na matriz.
O pH que favorece a adsorção dos íons foi 5,0 para Cu(II) e 3,0 para Cd(II) e As(V). O modelo cinético de pseudo segunda ordem apresentou melhor ajuste aos dados experimentais, indicando adsorção química. Os dados de sorção desses íons metálicos mostraram bom ajuste ao modelo de Langmuir, com capacidade máxima de adsorção próxima aos valores obtidos experimentalmente, 0,057, 0,018 e 0,060 mmol g-1 para Cu(II), Cd(II) e As(V), respectivamente, indicando que a sorção ocorre em monocamada. Os parâmetros analíticos encontrados para o Cu(II) foram: fator de pré-concentração de 18,1; intervalo linear de 10,0 – 200,0 µg L-1 (R = 0,999) e LD de 1,45 µg L-1. Para o Cd(II): fator de pré-concentração de 15,8; intervalo linear de 2,0 – 100,0 µg L-1 (R = 0,999) e LD de 0,38 µg L-1. Para o As(V): fator de pré-concentração de 5,0; intervalo linear de 0,25 – 2,5 µg L-1 (R = 0,999) e LD de 0,039 µg L-1. A exatidão foi checada pelo método de adição e recuperação e/ou método comparativo com GFAAS ou ICP OES. As recuperações variaram de 97 – 106% (Cu), 100 – 105% (Cd), 88 – 103% (As(V)) e 96 – 106% (As(total)). Os resultados para Cu(II) determinados com os métodos propostos foram concordantes com os obtidos com o método comparativo. Conclui-se que o material produzido apresenta bom potencial para ser aplicado na extração/pré-concentração de cobre, cádmio e análise de especiação inorgânica de arsênio. Provou-se também que baixos limites de detecção e quantificação podem ser obtidos mesmo utilizando uma técnica menos sensível como a FAAS. / This paper reports on the development of analytical methods for the determination of some toxic and potentially toxic species in ultra - trace levels in natural water samples using a less sensitive analytical technique such as flame atomic absorpti on spectrometry (FAAS). This technique was chosen because it is relatively simple and has a low operating cost. The solid phase extraction technique (SPE) using a new sorbent material was used to separate and preconcentrate the analyte. This study demonstr ates the procedure of a new synthetic route using the technique of the co - condensation for the production of a mesoporous organo - functionalised silica with the 4 - amino - 3 - hydrazino - 5 - mercapto - 1,2,4 - triazole ligant and its use as a sorbent for preconcentrati on/ analysis of metal ion s speciation in water samples. The material produced was characterized by infra - red spectroscopy (FTIR), BET, 29 Si and 13 C nuclear magnetic resonance (NMR), among others. The adsorptive characteristics of this material were establis hed in batch studies, where the effect of pH, adsorption kinetics and maximum adsorption capacity were studied. Multivariate optimization was used to obtain the best chemical and flow conditions in the preconcentration system, allowing the evaluation of th e main and secondary interactions among the factors. By means of the analysis of the spectra obtained by FTIR, it was possible to observe C - H, C - Cl and (NH 2 ) stretch bands from the organic fraction of the material. The surface area was 369.84 m 2 g - 1 with a verage pore diameter at 7.1 nm related to mesoporous materials. The results obtained by 29 Si NMR prove the formation of the hybrid material, synthesized by co - condensation, and the 13 C NMR confirms the anchoring of the ligan t in the matrix. The pH 5.0 it w as favors the adsorption of the ions Cu (II), the pH 3.0 it was favors the adsorption of the Cd (II) and As (V). The kinetic model of pseudo second order showed better adjustment to the experimental data, indicating chemical adsorption. The adsorption data of Cu (II), Cd (II), and As (V) were similar to those of the Langmuir model, with a maximum adsorption capacity of 0.057, 0.018 and 0.060 mmol g - 1 for Cu (II), Cd(III) and As(V) , respectively, indicating that the sorption occurs in monolayer. The analyt ical parameters for Cu (II) were: preconcentration factor of 18.1; linear range of 10.0 - 200.0 μg L - 1 (R = 0.999) and LD of 1.45 μg L - 1 . For Cd (II): preconcentration factor of 15.8; linear range of 2.0 - 100.0 μg L - 1 (R = 0.999) and LD of 0.38 μg L - 1 . Fo r As (V): preconcentration factor of 5.0; linear range of 0.25 - 2.5 μg L - 1 (R = 0.999) and LD of 0.039 μg L - 1 . Accuracy was checked by addi tion and recovery method of the standard and/ or comparative method with GFAAS or ICP OES. The recovery ranged from 97 - 106% Cu(II), 100 - 105% Cd (II), 88 - 103% As (V) and 96 - 106% As (total)). The results for Cu (II) determined with the proposed methods were concordant with those obtained with the comparative. It is concluded that the material produced can be successfully applied in the extraction / preconcentration of copper, cadmium and analysis of inorganic speciation of arsenic and low limits of detection and quantification can be obtained even using a less sensitive technique such as FAAS.
|
Page generated in 0.1017 seconds