• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 4
  • 3
  • Tagged with
  • 28
  • 28
  • 17
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Vérification de la reconstruction du signal d'onde gravitationnelle de Virgo à l'aide d'un dispositif d'étalonnage utilisant la pression de radiation laser / Check of the Virgo gravitational wave signal reconstruction with a calibration system based on laser radiation pressure"

Accadia, Timothée 15 November 2012 (has links)
Les ondes gravitationnelles sont des solutions aux équations gourvenant la dynamique de la gravitation prédite en 1918 à partir de la théorie de la Relativité Générale d'Einstein. Elles représentent la propagation d'une oscillation de l'espace-temps induisant d'infimes variations de distance sur leur passage entre des masses libres. Depuis deux décennies, un réseau d'interféromètres de Michelson kilométriques a été développé et mis en opération à travers le monde afin de prouver l'existence des ondes gravitationnelles en détectant leur passage sur Terre. Leur signature est recherchée dans un canal de détection étalonné, obtenu à partir des mesures fournies par le détecteur et reconstruisant le signal absolu d'une onde gravitationnelle le traversant. La vérification de la procédure est nécessaire pour déceler d'éventuelles erreurs systématiques d'étalonnage biaisant l'exploitation du canal par les analyses des données. Depuis plusieurs années, une nouvelle technique d'étalonnage est développée à cette fin dans les différents interféromètres du réseau et repose sur la pression de radiation d'un laser modulé en puissance afin d'induire un déplacement étalonné de l'un de ses miroirs. Le dispositif, appelé étalonneur laser, permet de reproduire le passage d'une onde gravitationnelle connue et d'en vérifier la reconstruction dans le canal de détection. Le travail de cette thèse a concerné la mise en \oe uvre de cette technique pour l'interféromètre franco-italien Virgo afin de vérifier la reconstruction de son signal d'onde gravitationnelle. Le principe de fonctionnement de l'étalonneur laser installé sur le site est d'abord détaillé et son étalonnage est ensuite décrit avec les campagnes de mesures réalisées. Enfin, les vérifications faites durant les deux périodes de prises de données de Virgo qui se sont déroulées entre 2010 et 2011 seront présentées. Les résultats ont permis de valider la reconstruction du signal d'onde gravitationnelle de Virgo et ses incertitudes confirmant leur impact négligeable sur l'analyse des données. / Gravitational waves are solutions to equations governing the dynamics of gravitation predicted from Einstein's theory of General Relativity in 1918. Gravitational waves describe ripples of space-time producing weak variations of distance between free masses along their propagation. Over the past two decades, an international array of ground-based, kilometer-scale Michelson interferometers has been developed to detect gravitational waves going through Earth and is now in operation. The gravitational wave signature is sought in a calibrated stream obtained from detector output measurements and giving the absolute signal of a gravitational waves going through it. A check of the procedure is required to avoid potential systematic calibration errors leading to an incorrect data stream and bias in its use by data analysis. Since severals years, a new calibration technique is developed for that purpose for each network's interferometer and uses the radiation pressure of a power-modulated laser to induce calibrated displacements of their mirrors. The associated setup, called Photon Calibrator, allows to mimic a gravitational waves passing the detector in order to verify its reconstruction in the detection channel. The scope of this thesis is the implementation of this technique for the French-Italian interferometer Virgo to check its gravitational wave signal reconstruction procedure. The operating principle of the setup installed is first described and its calibration is then detailed with measurement campaigns performed. Finally verifications performed for the two Virgo Science runs performed between 2010 and 2011 are presented. The conclusion of this study allowed to the validate the Virgo gravitational wave signal reconstruction with its uncertainties and has confirmed their negligeable impact on data analysis.
22

Analyse des effets acoustiques à haute fréquence/haute intensité sur l'injection coaxiale : application aux moteurs-fusées / Analysis of high-frequency/high-amplitude acoustic field effects on coaxial injection : application to liquid rocket engines

Ficuciello, Antonio 08 June 2017 (has links)
Le contexte de ce travail repose sur l'étude des instabilités de combustion au sein des moteurs-fusées à propergols liquides. Cette étude se concentre sur les effets des champs acoustiques transverses de haute amplitude sur l'injection coaxiale en conditions non-réactives. La réponse acoustique du système d'injection est dépendante des propriétés locales du champ acoustique dans la cavité d'injection. La modification du processus d'atomisation, induit par le champ acoustique, a été analysée dans des configurations simples et multiinjection. Des expériences ont été menées pour des régimes d'atomisation de faibles et hauts nombres de Weber. Trois phénomènes ont été observés: un aplatissement du jet, une amélioration du processus d'atomisation et la déviation du système liquide. La combinaison de ces trois phénomènes en configuration multi-injection résulte en un phénomène de regroupement de gouttes. En présence de combustion, un tel regroupement pourraitmener à un dégagement de chaleur non-uniforme susceptible de déclencher ou d'entretenir des instabilités de combustion. Un modèle théorique basé sur les équations d'acoustique non-linéaire a été développé pour donner les expressions générales de pression de radiation et de forces de radiations résultantes appliqué aux objets sphériques et cylindriques en champ stationnaire ou progressif. Le modèle a été utilisé pour interpréter et quantifier les observations expérimentales en configurations liquide/gaz, trans-critique/super-critique et gaz/gaz, et a permis de montrer que le nombre de Helmholtz qui caractérise le champ acoustique, et le rapport de densité qui caractérise les deux milieux, sont deux paramètres cruciaux. Les principales conclusions montrent que le phénomène observé peut être interprété comme résultant de l'acoustique non-linéaire, dont le paramètre clé étant le ratio de densité. Cela exige que la couche séparant les deux milieux, vue comme une interface, ne doive pas être réduite uniquement à une interface liquide/gaz. / The context of this work relies to high frequency combustion instabilities in Liquid Rocket Engines (LRE). The present research focuses on the effects of high amplitude transverse acoustic fields on non-reactive coaxial injection. The acoustic response of injection domes is found to be dependent on the local properties of the acoustic field in the injection cavity. The modification of the atomization process, induced by the acoustic field, has been analyzed in single and multi-injection configurations. Experiments were performed from low to high Weber number atomization regimes. Three phenomena are observed: jet flattening, improvement of the atomization process and deviation. The combination of these phenomena in multi-injection configurations leads to a droplet clustering phenomenon. In the presence of combustion, such a clustering could lead to non-uniform heat release rate which can trigger or sustain combustion instabilities. A theoretical model based on non-linear acoustics has been developed, providing general expressions of radiation pressure and resulting radiation force, for spherical and cylindrical objects in standing and progressive wave field. The model has been successfully used to interpret and quantify experimental observations in liquid/gas, trans-critical/super-critical and gas/gas configurations and showed that the Helmholtz number α characterizing the acoustic field and the density ratio η characterizing the two media are two parameters of importance. The major conclusions are that the observed phenomena can be interpreted as resulting from non-linear acoustics, the key feature being the density ratio. It is claimed that the layer separating the two media, seen as an interface, does not need to be restricted only to a liquid/gas interface.
23

Développement d'une nouvelle méthode de caractérisation tissulaire basée sur l'élastographie ultrasonore : application pour le dépistage précoce du cancer du sein

Ouared, Abderrahmane 09 1900 (has links)
Le cancer du sein est le cancer le plus fréquent chez la femme. Il demeure la cause de mortalité la plus importante chez les femmes âgées entre 35 et 55 ans. Au Canada, plus de 20 000 nouveaux cas sont diagnostiqués chaque année. Les études scientifiques démontrent que l'espérance de vie est étroitement liée à la précocité du diagnostic. Les moyens de diagnostic actuels comme la mammographie, l'échographie et la biopsie comportent certaines limitations. Par exemple, la mammographie permet de diagnostiquer la présence d’une masse suspecte dans le sein, mais ne peut en déterminer la nature (bénigne ou maligne). Les techniques d’imagerie complémentaires comme l'échographie ou l'imagerie par résonance magnétique (IRM) sont alors utilisées en complément, mais elles sont limitées quant à la sensibilité et la spécificité de leur diagnostic, principalement chez les jeunes femmes (< 50 ans) ou celles ayant un parenchyme dense. Par conséquent, nombreuses sont celles qui doivent subir une biopsie alors que leur lésions sont bénignes. Quelques voies de recherche sont privilégiées depuis peu pour réduire l`incertitude du diagnostic par imagerie ultrasonore. Dans ce contexte, l’élastographie dynamique est prometteuse. Cette technique est inspirée du geste médical de palpation et est basée sur la détermination de la rigidité des tissus, sachant que les lésions en général sont plus rigides que le tissu sain environnant. Le principe de cette technique est de générer des ondes de cisaillement et d'en étudier la propagation de ces ondes afin de remonter aux propriétés mécaniques du milieu via un problème inverse préétabli. Cette thèse vise le développement d'une nouvelle méthode d'élastographie dynamique pour le dépistage précoce des lésions mammaires. L'un des principaux problèmes des techniques d'élastographie dynamiques en utilisant la force de radiation est la forte atténuation des ondes de cisaillement. Après quelques longueurs d'onde de propagation, les amplitudes de déplacement diminuent considérablement et leur suivi devient difficile voir impossible. Ce problème affecte grandement la caractérisation des tissus biologiques. En outre, ces techniques ne donnent que l'information sur l'élasticité tandis que des études récentes montrent que certaines lésions bénignes ont les mêmes élasticités que des lésions malignes ce qui affecte la spécificité de ces techniques et motive la quantification de d'autres paramètres mécaniques (e.g.la viscosité). Le premier objectif de cette thèse consiste à optimiser la pression de radiation acoustique afin de rehausser l'amplitude des déplacements générés. Pour ce faire, un modèle analytique de prédiction de la fréquence de génération de la force de radiation a été développé. Une fois validé in vitro, ce modèle a servi pour la prédiction des fréquences optimales pour la génération de la force de radiation dans d'autres expérimentations in vitro et ex vivo sur des échantillons de tissu mammaire obtenus après mastectomie totale. Dans la continuité de ces travaux, un prototype de sonde ultrasonore conçu pour la génération d'un type spécifique d'ondes de cisaillement appelé ''onde de torsion'' a été développé. Le but est d'utiliser la force de radiation optimisée afin de générer des ondes de cisaillement adaptatives, et de monter leur utilité dans l'amélioration de l'amplitude des déplacements. Contrairement aux techniques élastographiques classiques, ce prototype permet la génération des ondes de cisaillement selon des parcours adaptatifs (e.g. circulaire, elliptique,…etc.) dépendamment de la forme de la lésion. L’optimisation des dépôts énergétiques induit une meilleure réponse mécanique du tissu et améliore le rapport signal sur bruit pour une meilleure quantification des paramètres viscoélastiques. Il est aussi question de consolider davantage les travaux de recherches antérieurs par un appui expérimental, et de prouver que ce type particulier d'onde de torsion peut mettre en résonance des structures. Ce phénomène de résonance des structures permet de rehausser davantage le contraste de déplacement entre les masses suspectes et le milieu environnant pour une meilleure détection. Enfin, dans le cadre de la quantification des paramètres viscoélastiques des tissus, la dernière étape consiste à développer un modèle inverse basé sur la propagation des ondes de cisaillement adaptatives pour l'estimation des paramètres viscoélastiques. L'estimation des paramètres viscoélastiques se fait via la résolution d'un problème inverse intégré dans un modèle numérique éléments finis. La robustesse de ce modèle a été étudiée afin de déterminer ces limites d'utilisation. Les résultats obtenus par ce modèle sont comparés à d'autres résultats (mêmes échantillons) obtenus par des méthodes de référence (e.g. Rheospectris) afin d'estimer la précision de la méthode développée. La quantification des paramètres mécaniques des lésions permet d'améliorer la sensibilité et la spécificité du diagnostic. La caractérisation tissulaire permet aussi une meilleure identification du type de lésion (malin ou bénin) ainsi que son évolution. Cette technique aide grandement les cliniciens dans le choix et la planification d'une prise en charge adaptée. / Breast cancer is the most frequent cancer in women and the leading cause of death for women between 35 and 55 years old. In Canada, more than 20,000 new cases are diagnosed each year. Most of the previous works have shown that life expectancy is closely related to the precocity of diagnosis. Current diagnostic imaging methods such as mammography, sonography, MRI present limitations such as irradiation (mammography), low specificity and low resolution (sonography) and high cost (MRI). For example, about 95% of abnormalities detected by mammography are proven to be benign lesions after complementary examinations (biopsy). Sonography is useful as a complementary examination but the low resolution of its images, its low specificity (54% for women less than 50 years) and its operator dependent interpretation seriously limit the use of this modality alone. MRI is a non-invasive technique with a relatively high sensitivity (86% for women below 50 years), but its limitations are the high cost and the waiting time for medical examination, which dedicate it as a monitoring technique in high-risk patients. It is therefore necessary to examine new noninvasive and cost effective methods. In this context, dynamic elastography is a promising approach. It is an emerging quantitative medical imaging technique inspired from palpation and based on the determination of elastic properties (stiffness) of tissues. This thesis aims the development of a novel dynamic ultrasound elastography method for early detection of breast lesions. One of the main problems of dynamic elastography techniques using remote palpation (acoustic radiation force) is the strong attenuation of shear waves. After few wavelengths of propagation, displacement amplitudes considerably decrease and their tracking becomes difficult even impossible. This problem greatly affects biological tissue characterization. Moreover, these techniques give only the information about elasticity while recent studies show that some benign lesions have the same elasticity as malignant lesions which affect the specificity of these techniques and motivate investigation of other physical parameters (e.g. viscosity). The first objective of this thesis is to optimize the acoustic radiation force using frequency adaptation to enhance the amplitude of displacements. An analytical model has been developed to predict the optimal frequency for the generation of the radiation force. Once validated on phantoms (in vitro), this model was used for the prediction of the optimal frequencies for the generation of the radiation force in tissue mimicking phantoms and ex vivo human breast cancer samples obtained after total mastectomy. Gains in magnitude were between 20% to158% for in vitro measurements on agar-gelatin phantoms, and 170% to 336% for ex vivo measurements on a human breast sample, depending on focus depths and attenuations of tested samples. The signal-to-noise ratio was also improved by more than four folds with adapted sequences. We conclude that frequency adaptation is a complementary technique that is efficient for the optimization of displacement amplitudes. This technique can be used safely to optimize the deposited local acoustic energy, without increasing the risk of damaging tissues and transducer elements. In the second part of this thesis, a prototype of an ultrasound probe for the generation of a specific type of adaptive shear waves called ''adaptive torsional shear waves'' has been developed. The goal was to use the optimized radiation force (developed in the first part) to generate adaptive torsional shear wave, and prove their utility in improving the amplitude of displacement. During their inward propagation, the amplitude of displacement generated by torsional shear waves was enhanced and the signal to noise ratio improved due to the constructive interferences. Torsional shear waves can also resonate heterogeneities which further enhance the displacement contrast between suspicious masses and its surrounding medium. Finally, in the context of assessment of mechanical proprieties of tissue, the last step of this thesis is to develop an inverse problem based on the propagation of adaptive torsional shear waves to estimate the viscoelastic parameters. A finite element method (FEM) model was developed to solve the inverse wave propagation problem and obtain viscoelastic properties of interrogated media. The inverse problem was formulated and solved in the frequency domain and its robustness was evaluated. The proposed model was validated in vitro with two independent rheology methods on several homogeneous and heterogeneous breast tissue mimicking phantoms over a broad range of frequencies (up to 400Hz). The obtained results were in good agreement with reference rheology methods with discrepancies between 8% and 38% for shear modulus and from 9% to 67% for loss modulus. The robustness study showed that the proposed inverse problem solution yielded a good estimation of the storage (19%) and loss moduli (32%) even with very noisy signals.
24

Résonateurs nano-optomécaniques à mode de galerie sur puce

Baker, Christopher 10 October 2013 (has links) (PDF)
Ces travaux de thèse portent sur la conception, la fabrication et la caractérisation de résonateurs nano-optomécaniques sous forme de disques en arséniure de Gallium (GaAs). Ces disques sont à la fois des résonateurs mécaniques oscillant au GHz, et des résonateurs optiques à mode de galerie à haut facteur de qualité (>10^5). En confinant l'énergie mécanique et optique sur un volume sub-µm^3, ils permettent d'atteindre un couplage optomécanique extrêmement large (g0 >1 MHz). Nous présentons les développements technologiques ayant permis l'intégration de ces résonateurs avec des guides de couplage optique directement sur échantillon semi-conducteur, tout en maintenant des performances à l'état de l'art. Nous discutons les différents mécanismes de couplage optomécanique (pression de radiation, photoélasticité) dans les disques GaAs, ainsi que les sources de dissipation optique et mécanique dans ces résonateurs. Nous présentons également des expériences d'optomécanique à l'air libre et en cryostat à basse température, allant de la mesure du mouvement brownien et l'observation de rétroaction dynamique, jusqu'à des premières tentatives d'approche du régime quantique du mouvement. Enfin, nous présentons un développement nano-optomécanique complémentaire mené sur le matériau nitrure de silicium (SiN), aboutissant à la fabrication de résonateurs à mode de galerie sur puce à haut facteur de qualité. Après l'étude des instabilités optiques et de la dynamique d'auto-pulsation de ces résonateurs, nous présentons des premières signatures de couplage optomécanique dissipatif dans ces systèmes.
25

Caractérisation des planètes extrasolaires et de leurs atmosphères (Spectroscopie des transits et échappement atmosphérique)

Bourrier, Vincent 04 September 2014 (has links) (PDF)
Les Jupiters chauds sont des exoplanètes si proches de leur étoile que leur atmosphère peut perdre du gaz par échappement hydrodynamique. Les géantes gazeuses qui transitent sont un excellent moyen de comprendre ce processus, mais il faut étudier d'autres types de planètes pour déterminer son impact sur la population exoplanétaire. Cette thèse propose d'utiliser la spectroscopie du transit pour observer l'atmosphère de plusieurs planètes, étudier leurs propriétés et caractériser l'échappement hydrodynamique. Des raies de l'ultraviolet observées avec le télescope Hubble sont analysées avec le modèle numérique de la haute atmosphère que nous avons développé. Grâce à la raie Ly-? nous mettons en évidence les interactions énergétiques et dynamiques entre l'atmosphère des Jupiters chauds HD209458b et HD189733b et leurs étoiles. Nous étudions la dépendance de l'échappement à l'environnement d'une planète et à ses propriétés physiques, en observant une super-Terre et un Jupiter tiède dans le système 55Cnc. Grâce à des observations de HD209458b nous montrons que les raies du magnésium permettent de sonder la région de formation de l'échappement. Nous étudions le potentiel de la spectroscopie du transit dans le proche UV pour détecter de nouveaux cas d'échappement. Ce mécanisme est favorisé par la proximité d'une planète à son étoile, ce qui rend d'autant plus important la compréhension des processus de formation et de migration, qui peuvent être étudiés par l'alignement d'un système planétaire. Grâce à des mesures des spectrographes HARPS-N et SOPHIE nous étudions les alignements de 55Cnc e et du candidat Kepler KOI-12.01, dont nous cherchons aussi à valider la nature planétaire.
26

Quantum and dynamical back-action effects using a gram-scale mechanical resonator in a high-finesse optical cavity

Tavernarakis, Alexandros 20 December 2012 (has links) (PDF)
L'optomécanique en cavité, l'étude de l'interaction entre le mode d'une cavité optique et un mode mécanique d'un résonateur, a eu une évolution impressionnante depuis dix ans et elle est devenue un nouveau champ de recherche, réunissant la physique de la matière condensée et l'optique. Un des objectifs majeurs de cette discipline est de tester et étudier la mécanique quantique en utilisant des systèmes macroscopiques. Parmi les problèmes les plus fondamentaux que la communauté aborde est la question des limites quantiques de la mesure de position. La mécanique quantique prédit que toute mesure s'accompagne d'une action en retour, ce qui perturbe l'état du système mesure. En outre, il devrait être conjugué avec le bruit quantique de l'appareil de mesure (le bruit de mesure) utilisé pour sonder le système. La sensibilité optimale est atteinte lorsque la mesure et le bruit backaction sont identiques, une situation qui peut être assimilé à l'acceptation de l'inégalité de Heisenberg pour l'appareil de mesure. En optomecanique, le mode d'une cavité optique est utilisé comme un appareil de mesure de la position d'un résonateur mécanique qui est piloté par la pression de radiation qui devrait être responsable pour l'action en retour de la mesure. Cependant, cette action en retour n'a jamais été observé à ce jour, alors qu'il reste une étape décisive vers la compréhension des processus de la mesure quantique. Nous décrivons dans ce manuscrit l'étude des effets de la pression de radiation. Nous introduisons le système opto-mécanique que nous avons développé qui consiste a un résonateur mécanique plan-convex de taille de quelques cm présentant un très haut facteur de qualité (~ 1 000 000) intégré dans une cavité Fabry-Perot de très grande finesse (~ 300 000). Nous présentons deux résultats importants que nous avons obtenus avec ce système. Tout d'abord, nous avons rapporté la première observation directe de la pression de radiation en temps réel, basée sur l'établissement des corrélations pompe-sonde. Nous avons également démontré pour la première fois des effets non linéaires dû a l'action en retour liés à l'amélioration substantielle de la sensibilité de la mesure de position. Nous expliquons pourquoi la démonstration de l'action en retour quantique nécessite une ultra- haute stabilité du mode optique. Nous présentons les modifications importantes apportées à la configuration expérimentale précédente, notamment sur la source laser, la détection et la stabilisation de l'expérience. Nous décrivons ensuite une nouvelle technique de détection opto-mécanique fournissant une mesure indépendante du désaccord cavité. Enfin, nous présentons une expérience de validation de principe permettant d'extraire des corrélations quantiques optomécaniques à la température ambiante.
27

Effet d'ultrasons de puissance sur les matériaux mous : vers des matériaux "acousto-rhéologiques" / Effect of high intensity ultrasound on soft materials : towards « rheo-acoustical » materials

Lidon, Pierre 08 July 2016 (has links)
Les méthodes d'imagerie et de vélocimétrie ultrasonores ont prouvé leur efficacité pour étudier des matériaux divers. À haute intensité, il est connu que les ultrasons exercent des forces stationnaires dans les fluides newtoniens, par le biais d'effets non linéaires comme la pression de radiation acoustique. Néanmoins, ces effets n'ont encore jamais été exploités d'un point de vue fondamental dans le contexte de la physique des matériaux mous. L'objet de cette thèse est d'exploiter l'interaction d'ultrasons de puissance avec des matériaux bloqués afin de sonder activement, voire d'influencer leurs propriétés mécaniques. Nous proposons tout d'abord une méthode de microrhéologie active : la « mésorhéologie acoustique ». En analysant le mouvement d'un intrus sous l'effet de la pression de radiation acoustique, nous caractérisons localement la rhéologie du matériau étudié. Nous mettons cette technique en œuvre avec un fluide à seuil simple : un microgel de carbopol. Nous exploitons les résultats obtenus à la lumière d'une caractérisation rhéologique poussée du comportement de ce matériau en dessous de son seuil d'écoulement et proposons diverses pistes d'amélioration du dispositif.Ensuite, nous décrivons la mise en écoulement d'un empilement granulaire immergé par des ultrasons intenses focalisés et comparons les observations aux résultats de simulations de dynamique moléculaire. La transition de fluidification observée car l'injection d'énergie y est discontinue. Elle est intermittente et hystérétique, propriétés reproduites par des simulations numériques et dont un modèle phénoménologique simple permet de rendre compte.Enfin, en remplaçant le plan d'un rhéomètre classique par un transducteur ultrasonore, nous mesurons l'effet de vibrations à haute fréquence sur les propriétés mécaniques d'un gel colloïdal fragile de noir de carbone. Nous observons un effet significatif et potentiellement irréversible des ultrasons sur le module élastique et sur la mise en écoulement de ce système. Les vibrations semblent favoriser le glissement du gel aux parois mais il semble toutefois qu'elles induisent également des changements en volume dans l'échantillon. / Ultrasonic imaging and velocimetry has been proved to be very efficient methods to study various materials. At high intensity, ultrasonic waves are known to exert steady forces in newtonian fluid through nonlinear effects like the acoustic radiation pressure. However those effects have never been used in fundamental studies of the physics of soft materials. This thesis aims at exploiting the interaction between high intensity ultrasound and soft jammed materials to probe actively and even modify their mechanical properties.We first introduce an alternative technique for active microrheology we called « acoustic mesorheology ». By analyzing the motion of an intruder under the acoustic radiation pressure we characterize locally the rheology of the system under study. We test this technique on a simple yield stress fluid, namely a carbopol microgel. We compare the results with those obtained by standard rheology measurements of the behaviour of this gel under its yield stress.Then we describe the fluidization of an immersed granular packing by high intensity focused ultrasound. We compare our observations with the results of molecular dynamics simulations. The obtained fluidization is original as the injection of energy is discontinuous in time. It is hysteretic and intermittent and those properties are well captures by both simulations and a phenomenological model.Finally, we replace the plane of a standard cone-plate rheometer by an ultrasonic transducer. This allows us to characterize the effect of high frequency vibrations on the rheology of a fragile carbon black gel. We observe a significant and eventually irreversible effect of ultrasound on the elastic modulus and on the yielding of the system. Vibrations are shown to favor wall slip but seem to induce changes in the volume of the sample though.
28

Vers l’observation du bruit quantique de la pression de radiation dans un interféromètre suspendu : l’expérience QuRaG / Towards the observation of the radiation pressure noise in a suspended interferometer : the QuRaG experiment

Di Pace, Sibilla 15 December 2014 (has links)
L'existence des ondes gravitationnelles (OG) est l'une des prédictions les plus intéressantes de la théorie de la Relativité Générale d'Einstein. La découverte expérimentale des OG serait donc un test important de la théorie elle-même et permettra d'ouvrir une nouvelle fenêtre d'observation en particulier dans les régions de l'Univers inaccessible à l'observation électromagnétique. Les détecteurs interférométriques, comme Virgo, sont les dispositifs les plus prometteurs pour la détection d’OG. Actuellement, leur sensibilité n'est pas encore suffisante pour avoir un taux d'observation de quelques événements/an. Un intense programme expérimental pour l’améliorer est en cours. Particulièrement, les prochaines générations de détecteurs d'OG, aux basses fréquences, seront limitées par l'effet de la pression de radiation (PR) sur les miroirs suspendus. Ce phénomène, pas encore observé expérimentalement, est l'objet d'un champ de recherche très actif. Mon travail ici présenté vise à la construction d'un détecteur pour l'étude des effets quantiques de la PR dans les détecteurs d’OG: QuRaG. Il sera constitué d'un interféromètre de Michelson suspendu dont chaque bras sera une cavité Fabry-Pérot de très haute finesse, dans laquelle seulement le miroir de fond sera suspendu et sensible au bruit quantique de la PR. Durant ma thèse j'ai participé activement au R&D de tous les sous-systèmes de QuRaG. Par conséquent, le travail que j'ai fait porte sur divers aspects du projet dont les problématiques appartiennent à différents domaines de la physique. Mon travail présenté ici démontre que QuRaG sera réalisable et qu’il observera le bruit de la PR dans la bande de fréquences attendue. / The existence of gravitational waves (GW) is one of the most interesting predictions of the theory of general relativity of Einstein. The experimental discovery of GW would be an important test of the theory itself. In addition, the detection of GW will open a new window of observation especially in those regions of the Universe inaccessible to electromagnetic observations. Interferometers, as Virgo are the most promising devices for the detection of GW. Currently, the sensitivity of these detectors is not yet sufficient to have a detection rate of few events/year. Therefore, an intense experimental program to improve the sensitivity is underway. Specifically, the sensitivity of the next generations of GW detectors, at low frequencies, will be limited by the effect of the radiation pressure (RP) on the suspended mirrors. This phenomenon not yet observed experimentally in the ground based GW detectors band, is currently the subject of a very active research field. My work presented here aims at building a detector for studying quantum effects of RP in GW detectors: the QuRaG experiment. It will consist of a suspended Michelson interferometer where each arm will be a high finesse Fabry-Pérot cavity, in which only the end mirror will be further suspended and then sensitive to the RP noise. During my PhD I have actively participated to the R&D of all QuRaG subsystems. Therefore, the work that I have done deals with various aspects of the project whose related problems belong to different domains of physics. My work described in this manuscript demonstrates that QuRaG is realizable and that it will be able to observe the RP noise in the expected frequency range.

Page generated in 0.1457 seconds