• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 28
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 96
  • 96
  • 64
  • 60
  • 27
  • 18
  • 16
  • 16
  • 16
  • 16
  • 14
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Comparação entre prótese plástica e metálica na paliação endoscópica da obstrução maligna da via biliar: revisão sistemática e metanálise baseadas em estudos randomizados / Endoscopic stenting for inoperable malignant biliary obstruction: a systematic review and meta-analysis

Leonardo Zorrón Cheng Tao Pu 12 April 2016 (has links)
INTRODUÇÃO: A prótese biliar endoscópica é aceita em todo o mundo como a primeira escolha de tratamento paliativo na obstrução biliar maligna. Atualmente ainda persistem dois tipos de materiais utilizados em sua confecção: plástico e metal. Consequentemente, muitas dúvidas surgem quanto a qual deles é o mais benéfico para o paciente. Esta revisão reúne as informações disponíveis da mais alta qualidade sobre estes dois tipos de prótese, fornecendo informações em relação à disfunção, complicação, taxas de reintervenção, custos, sobrevida e tempo de permeabilidade; e pretende ajudar a lidar com a prática clínica nos dias de hoje. OBJETIVO: Analisar, através de metanálise, os benefícios de dois tipos de próteses na obstrução biliar maligna inoperável. MÉTODOS: Uma revisão sistemática de ensaios clínicos randomizados (RCT) foi conduzida, com a última atualização em março de 2015, utilizando EMBASE, CINAHL (EBSCO), Medline, Lilacs / Centro (BVS), Scopus, o CAPES (Brasil), e literatura cinzenta. As informações dos estudos selecionados foram extraídas tendo em vista seis desfechos: primariamente disfunção, taxas de reintervenção e complicações; e, secundariamente, custos, sobrevivência e tempo de permeabilidade. Os dados sobre as características dos participantes do RCT, critérios de inclusão e exclusão e tipos de próteses também foram extraídos. Os vieses foram avaliados principalmente através da escala de Jadad. Esta metanálise foi registrada no banco de dados PROSPERO pelo número CRD42014015078. A análise do risco absoluto dos resultados foi realizada utilizando o software RevMan 5, calculando as diferenças de risco (RD) de variáveis dicotômicas e média das diferenças (MD) de variáveis contínuas. Os dados sobre a RD e MD para cada desfecho primário foram calculados utilizando o teste de Mantel-Haenszel e a inconsistência foi avaliada com o teste Qui-quadrado (Chi2) e o método de Higgins (I2). A análise de sensibilidade foi realizada com a retirada de estudos discrepantes e a utilização do efeito aleatório. O teste t de Student foi utilizado para a comparação das médias aritméticas ponderadas, em relação aos desfechos secundários. RESULTADOS: Inicialmente foram identificados 3660 estudos; 3539 foram excluídos por título ou resumo, enquanto 121 estudos foram totalmente avaliados e foram excluídos, principalmente por não comparar próteses metálicas (SEMS) e próteses plásticas (PS), levando a treze RCT selecionados e 1133 indivíduos metanálise. A média de idade foi de 69,5 anos, e o câncer mais comum foi de via biliar (proximal) e pancreático (distal). O diâmetro de SEMS mais utilizado foi de 10 mm (30 Fr) e o diâmetro de PS mais utilizado foi de 10 Fr. Na metanálise, SEMS tiveram menor disfunção global em comparação com PS (21,6% versus 46,8% p < 0,00001) e menos reintervenções (21,6% versus 56,6% p < 0,00001), sem diferença nas complicações (13,7% versus 15,9% p = 0,16). Na análise secundária, a taxa média de sobrevida foi maior no grupo SEMS (182 contra 150 dias - p < 0,0001), com um período maior de permeabilidade (250 contra 124 dias - p < 0,0001) e um custo semelhante por paciente, embora menor no grupo SEMS (4.193,98 contra 4.728,65 Euros - p < 0,0985). CONCLUSÃO: SEMS estão associados com menor disfunção, menores taxas de reintervenção, melhor sobrevida e maior tempo de permeabilidade. Complicações e custos não apresentaram diferença / INTRODUCTION: Endoscopic stenting is accepted worldwide as the first choice palliative treatment for malignant biliary obstruction. There are still two types of materials currently being used, which are plastic and metal. Therefore, many doubts are raised as to which one is the most beneficial to the patient. This review gathers the highest quality information available about these two types of stent, giving information in regards to dysfunction, complication, reintervention rates, costs, survival, and patency time; and intends to help handle clinical practice nowadays. OBJECTIVE: To analyze through meta-analyses the benefits of two types of stents in the inoperable malignant biliary obstruction. METHODS: A systematic review of randomized clinical trials (RCT) was conducted, with the last update on March 2015, using EMBASE, CINAHL (EBSCO), MEDLINE, LILACS/CENTRAL (BVS), SCOPUS, CAPES (Brazil), and gray literature. Information of the selected studies was extracted in sight of six outcomes: primarily regarding dysfunction, reintervention and complication rates; and secondarily costs, survival, and patency time. The data about characteristics of trial participants, inclusion and exclusion criteria and types of stents were also extracted. The biases were mainly assessed through the Jadad scale. This meta-analysis was registered in the PROSPERO database by the number CRD42014015078. The analysis of the absolute risk of the outcomes was performed using the software RevMan 5, by computing risk differences (RD) of dichotomous variables and mean differences (MD) of continuous variables. Data on RD and MD for each primary outcome were calculated using the Mantel-Haenszel test and inconsistency was qualified and reported in Chisquared (Chi2) and the Higgins method (I2). Sensitivity analysis was performed withdrawing discrepant studies and using random effect. Student\'s t-test was used for the comparison of weighted arithmetic means regarding secondary outcomes. RESULTS: Initial searching identified 3660 studies; 3539 were excluded through title or abstract, while 121 studies were fully assessed and were excluded mainly because they did not compare Self Expanding Metal Stents (SEMS) and Plastic Stents (PS), leading to thirteen RCT selected and 1133 subjects meta-analyzed. The mean age was 69.5 years old, that were affected mostly by bile duct (proximal) and pancreatic tumors (distal). The preferred SEMS diameter used was the 10 mm (30 Fr) and the preferred PS diameter used was 10 Fr. In the meta-analysis, SEMS had lower overall stent dysfunction compared to PS (21.6% versus 46.8% p < 0.00001) and fewer reintervention (21.6% versus 56.6% p < 0.00001), with no difference in complications (13.7% versus 15.9% p=0.16). In the secondary analysis, the mean survival rate was higher in the SEMS group (182 versus 150 days - p < 0.0001), with a higher patency period (250 versus 124 days - p < 0.0001) and a similar cost per patient, although lower in the SEMS group (4193.98 versus 4728.65 Euros - p < 0.0985). CONCLUSION: SEMS are associated with lower stent dysfunction, lower reintervention rates, better survival, and higher patency time. Complications and costs do not show difference
92

Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantation

Lucas Bevilacqua Alves da Costa 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception
93

Tratamento endoscópico das estenoses biliares pós-transplante  hepático: revisão sistemática da literatura e metanálise / Endoscopic treatment of post-liver transplantation biliary strictures: systematic literature review and meta-analysis

Aparício, Dayse Pereira da Silva 30 June 2016 (has links)
As complicações biliares mais comuns pós-transplante hepático são as estenoses da anastomose, as estenoses não-anastomóticas e as fístulas biliares e podem ocorrer de diferentes modos, de forma isolada ou associada. A origem do enxerto (doador cadáver ou doador vivo) tem influência na incidência de estenose biliar, bem como na resposta ao tratamento endoscópico. A terapêutica endoscópica utilizando-se esfincterotomia, dilatação balonada da estenose e inserção de próteses biliares através da CPRE é utilizada como método inicial de tratamento dessas complicações. Objetivos: Comparar as diferentes técnicas de tratamento endoscópico das estenoses biliares pós-transplante hepático. Método: Foi realizada uma revisão sistemática da literatura e metanálise sendo a busca conduzida nas bases MEDLINE, EMBASE, Scielo - LILACS e Biblioteca Cochrane até junho de 2015. A metanálise foi executada utilizando-se os softwares Review Manager, 2012 (RevMan) versão 5.2 e OpenMetaAnalyst e os cálculos dos desfechos foram feitos comparando-se os resultados dos estudos incluídos utilizando-se a diferença de risco absoluto e adotando-se um intervalo de confiança (IC) de 95%. Os estudos foram agrupados comparando-se transplantes hepáticos com doador cadáver versus doador vivo; dilatação biliar endoscópica com balão exclusiva versus dilatação biliar endoscópica com balão associada à inserção de próteses plásticas e próteses biliares plásticas comparadas à prótese biliar metálica por endoscopia. Os desfechos clínicos analisados foram incidência da estenose biliar, falha do tratamento endoscópico, resolução da estenose, recorrência da estenose e complicações. Resultados: Foram recuperados 1.110 artigos, sendo motivo de análise dez ensaios clínicos, com apenas um Ensaio Clínico Randomizado e nove Ensaios Clínicos não randomizados, dos quais sete foram incluídos na metanálise. Comparando-se doador cadáver e doador vivo observou-se redução da incidência de estenose biliar (p=0,0001), bem como da falha técnica do tratamento endoscópico (p=0,0009) e da recorrência da estenose biliar (p=0,03) nos transplantes realizados com enxertos provenientes de doador cadáver. Dois estudos compararam o tratamento da estenose da anastomose biliar pós-transplante hepático utilizando dilatação com balão exclusiva versus dilatação com balão associada à inserção próteses plásticas e não foram observadas diferenças estatisticamente significantes em relação aos desfechos falha de tratamento, recorrência da estenose ou complicações. Somente o desfecho clínico complicações teve resultado estatisticamente significante na comparação entre prótese metálica autoexpansível versus prótese plástica no tratamento da estenose da anastomose biliar pós-transplante hepático (p= 0.03). Conclusões: O tratamento da estenose biliar anastomótica pós-transplante hepático com prótese metálica foi igualmente efetivo quando comparado ao uso de prótese plástica, mas associou-se a um menor risco de complicações. A comparação entre dilatação com balão exclusiva e dilatação com balão associada à prótese plástica apresentou resultados semelhantes em relação à falha do tratamento endoscópico, complicações e recorrência da estenose. A utilização de enxerto proveniente de doador cadáver reduziu o risco de estenose biliar pós-transplante hepático e o tratamento endoscópico nesse grupo de pacientes, foi mais efetivo quando comparado com as estenoses biliares após transplante com doador vivo / The most common biliary complications after liver transplantation are anastomotic strictures, non-anastomotic strictures and biliary fistulas and they can occur in different fashions, isolated or in combination. Graft source (cadaveric liver donor or living liver donor) has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. The endoscopic treatment using sphincterotomy, balloon dilation and insertion of biliary stents by ERCP (Endoscopic Retrograde Cholangiopancreatography) is used as an initial endoscopic approach to treat these complications. Objectives: To compare different endoscopic techniques to treat post-liver transplantation biliary strictures. Method: It was performed a systematic review of the literature and meta-analysis and the search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases until June, 2015. The meta-analysis was made using Review Manager, 2012 (RevMan) version 5.2 and OpenMetaAnalyst software and the calculations of the outcomes were made comparing the results from the included papers by using the difference in absolute risks, adopting a confidence interval of 95%. The studies were grouped comparing cadaveric liver donor versus living liver donor grafts; exclusive balloon dilation versus balloon dilation associated with plastic stents insertion; and plastic stents versus totally covered selfexpandable metal stents. The clinical outcomes were biliary stricture incidence, endoscopic treatment failure, stricture resolution, stricture recurrence and complications. Results: There were retrieved 1,100 articles. Ten clinical trials were analyzed, with just one Randomized Clinical Trial and nine Non-Randomized Clinical Trials, out of which seven were included in the meta-analysis. When comparing cadaveric liver donor transplantation to living liver donor transplantation, it was observed a decrease in the incidence of biliary strictures (p=0.0001), as well as in the technical failure rate of the endoscopic treatment (p=0.0009) and in the biliary stricture recurrence (p=0.03) in the cadaveric liver donor graft group. Two studies have compared the treatment of anastomotic biliary strictures after liver transplantation using balloon dilation exclusive to balloon dilation associated with the insertion of plastic stents, and no statistically significant differences in relation to endoscopic treatment failure, stricture recurrence or complications rates were observed. Only the clinical outcome complications had statistically significant result in a comparison between self-expandable metal stents versus plastic stents in the treatment of post-liver transplantation anastomotic biliary strictures (p=0.03). Conclusions: The treatment of post-liver transplantation anastomotic biliary strictures was equally effective when compared the use of self-expandable metal stents to plastic stents, but the use metallic stents was associated with a lower complication risk. The comparison between exclusive balloon dilation to balloon dilation associated with plastic stents presented similar results in relation to endoscopic treatment failure, complications and stenosis recurrence. The use of graft from cadaveric donor reduced the risk of biliary stenosis after liver transplantation and endoscopic treatment of biliary strictures in these patients were more effective when compared to biliary strictures after living liver donor transplantation
94

Avaliação do impacto do processo de limpeza na esterilização de medidores de implantes mamários / Assesment of the cleaning process impact in sterilization of mamary implant sizers

Muradian Filho, José 12 November 2007 (has links)
O procedimento cirúrgico para implantes mamários inclui os chamados medidores, utilizados para a mensuração de volume e geometria antes colocação do implante definitivo na paciente. Esses dispositivos são constituídos por um invólucro de elastômero de silicone grau médico da classe siloxano ou poliuretano e cheios com volumes pré-estabelecidos de gel ou elastômero de silicone, grau médico, sendo apresentados em diversos volumes e formas equivalentes ao volume e forma do implante correspondente. Este trabalho avaliou o processo de limpeza manual dos medidores para implantes, sob o ponto de vista da redução da carga microbiana, propiciando a eficácia do processo de esterilização, nas condições encontradas nos Centros Cirúrgicos Hospitalares e utilizando seus equipamentos usuais. Foram realizados testes de desafio microbiológico em amostras de medidores com superfície texturizada e superfície revestida com poliuretano, utilizando cinco microrganismos (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans e Aspergillus niger) e dois tipos de detergente para comparação: não enzimático e enzimático. Determinou-se a biocarga antes e após a limpeza, e em seguida realizou-se a esterilização a 126°C por 30 minutos (1,4 kgf/cm2) das amostras, que foi avaliada por teste de esterilidade. Os resultados mostraram que a etapa de lavagem contribuiu para a redução de 4 ciclos logarítmicos da população inicialmente considerada e não houve diferença entre os resultados de biocarga dos medidores com superfície texturizada e superfície revestida com poliuretano. O processo de limpeza dos medidores com detergente não enzimático ou enzimático seguido de esterilização apresenta eficiência suficiente para garantir a esterilidade requerida para a utilização dos medidores. / The surgical procedure for mammary implants include the so called sizers, used to measure both volume and geometry prior to the definitive placement in the womans breast. These devices present a silicon elastomer or polyurethane external capsule, medical grade, siloxan class filled with predetermined gel or silicon elastomer volumes, also medical grade and are presented in several shapes and volumes equivalent to the shapes and volumes of the corresponding final implant. This study evaluated the manual cleaning process of the sizers focusing in the bioburden thus rendering an effective sterilization process, under the usual equipment and conditions found in the hospital surgery centers. Microbial challenge tests were performed using 5 microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus niger) and two types of detergent , non enzymatic and enzymatic for comparison. Bioburden was determined before and after the cleaning procedure and after that samples were sterilized at 126°C (1,4 kgf/cm2) for 30 minutes, which was evaluated through sterility testing. Results shown that the cleaning step contributed to a 4 log cycle reduction in the samples initial bioburden and that there was no difference between bioburden results in both types of sizers (textured or polyurethane capsule). The cleaning process using non enzymatic or enzymatic detergents followed by sterilization shows enough effectiveness to ensure the required sterility for using the sizers.
95

Avaliação do impacto do processo de limpeza na esterilização de medidores de implantes mamários / Assesment of the cleaning process impact in sterilization of mamary implant sizers

José Muradian Filho 12 November 2007 (has links)
O procedimento cirúrgico para implantes mamários inclui os chamados medidores, utilizados para a mensuração de volume e geometria antes colocação do implante definitivo na paciente. Esses dispositivos são constituídos por um invólucro de elastômero de silicone grau médico da classe siloxano ou poliuretano e cheios com volumes pré-estabelecidos de gel ou elastômero de silicone, grau médico, sendo apresentados em diversos volumes e formas equivalentes ao volume e forma do implante correspondente. Este trabalho avaliou o processo de limpeza manual dos medidores para implantes, sob o ponto de vista da redução da carga microbiana, propiciando a eficácia do processo de esterilização, nas condições encontradas nos Centros Cirúrgicos Hospitalares e utilizando seus equipamentos usuais. Foram realizados testes de desafio microbiológico em amostras de medidores com superfície texturizada e superfície revestida com poliuretano, utilizando cinco microrganismos (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans e Aspergillus niger) e dois tipos de detergente para comparação: não enzimático e enzimático. Determinou-se a biocarga antes e após a limpeza, e em seguida realizou-se a esterilização a 126°C por 30 minutos (1,4 kgf/cm2) das amostras, que foi avaliada por teste de esterilidade. Os resultados mostraram que a etapa de lavagem contribuiu para a redução de 4 ciclos logarítmicos da população inicialmente considerada e não houve diferença entre os resultados de biocarga dos medidores com superfície texturizada e superfície revestida com poliuretano. O processo de limpeza dos medidores com detergente não enzimático ou enzimático seguido de esterilização apresenta eficiência suficiente para garantir a esterilidade requerida para a utilização dos medidores. / The surgical procedure for mammary implants include the so called sizers, used to measure both volume and geometry prior to the definitive placement in the womans breast. These devices present a silicon elastomer or polyurethane external capsule, medical grade, siloxan class filled with predetermined gel or silicon elastomer volumes, also medical grade and are presented in several shapes and volumes equivalent to the shapes and volumes of the corresponding final implant. This study evaluated the manual cleaning process of the sizers focusing in the bioburden thus rendering an effective sterilization process, under the usual equipment and conditions found in the hospital surgery centers. Microbial challenge tests were performed using 5 microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus niger) and two types of detergent , non enzymatic and enzymatic for comparison. Bioburden was determined before and after the cleaning procedure and after that samples were sterilized at 126°C (1,4 kgf/cm2) for 30 minutes, which was evaluated through sterility testing. Results shown that the cleaning step contributed to a 4 log cycle reduction in the samples initial bioburden and that there was no difference between bioburden results in both types of sizers (textured or polyurethane capsule). The cleaning process using non enzymatic or enzymatic detergents followed by sterilization shows enough effectiveness to ensure the required sterility for using the sizers.
96

Tratamento endoscópico das estenoses biliares pós-transplante  hepático: revisão sistemática da literatura e metanálise / Endoscopic treatment of post-liver transplantation biliary strictures: systematic literature review and meta-analysis

Dayse Pereira da Silva Aparício 30 June 2016 (has links)
As complicações biliares mais comuns pós-transplante hepático são as estenoses da anastomose, as estenoses não-anastomóticas e as fístulas biliares e podem ocorrer de diferentes modos, de forma isolada ou associada. A origem do enxerto (doador cadáver ou doador vivo) tem influência na incidência de estenose biliar, bem como na resposta ao tratamento endoscópico. A terapêutica endoscópica utilizando-se esfincterotomia, dilatação balonada da estenose e inserção de próteses biliares através da CPRE é utilizada como método inicial de tratamento dessas complicações. Objetivos: Comparar as diferentes técnicas de tratamento endoscópico das estenoses biliares pós-transplante hepático. Método: Foi realizada uma revisão sistemática da literatura e metanálise sendo a busca conduzida nas bases MEDLINE, EMBASE, Scielo - LILACS e Biblioteca Cochrane até junho de 2015. A metanálise foi executada utilizando-se os softwares Review Manager, 2012 (RevMan) versão 5.2 e OpenMetaAnalyst e os cálculos dos desfechos foram feitos comparando-se os resultados dos estudos incluídos utilizando-se a diferença de risco absoluto e adotando-se um intervalo de confiança (IC) de 95%. Os estudos foram agrupados comparando-se transplantes hepáticos com doador cadáver versus doador vivo; dilatação biliar endoscópica com balão exclusiva versus dilatação biliar endoscópica com balão associada à inserção de próteses plásticas e próteses biliares plásticas comparadas à prótese biliar metálica por endoscopia. Os desfechos clínicos analisados foram incidência da estenose biliar, falha do tratamento endoscópico, resolução da estenose, recorrência da estenose e complicações. Resultados: Foram recuperados 1.110 artigos, sendo motivo de análise dez ensaios clínicos, com apenas um Ensaio Clínico Randomizado e nove Ensaios Clínicos não randomizados, dos quais sete foram incluídos na metanálise. Comparando-se doador cadáver e doador vivo observou-se redução da incidência de estenose biliar (p=0,0001), bem como da falha técnica do tratamento endoscópico (p=0,0009) e da recorrência da estenose biliar (p=0,03) nos transplantes realizados com enxertos provenientes de doador cadáver. Dois estudos compararam o tratamento da estenose da anastomose biliar pós-transplante hepático utilizando dilatação com balão exclusiva versus dilatação com balão associada à inserção próteses plásticas e não foram observadas diferenças estatisticamente significantes em relação aos desfechos falha de tratamento, recorrência da estenose ou complicações. Somente o desfecho clínico complicações teve resultado estatisticamente significante na comparação entre prótese metálica autoexpansível versus prótese plástica no tratamento da estenose da anastomose biliar pós-transplante hepático (p= 0.03). Conclusões: O tratamento da estenose biliar anastomótica pós-transplante hepático com prótese metálica foi igualmente efetivo quando comparado ao uso de prótese plástica, mas associou-se a um menor risco de complicações. A comparação entre dilatação com balão exclusiva e dilatação com balão associada à prótese plástica apresentou resultados semelhantes em relação à falha do tratamento endoscópico, complicações e recorrência da estenose. A utilização de enxerto proveniente de doador cadáver reduziu o risco de estenose biliar pós-transplante hepático e o tratamento endoscópico nesse grupo de pacientes, foi mais efetivo quando comparado com as estenoses biliares após transplante com doador vivo / The most common biliary complications after liver transplantation are anastomotic strictures, non-anastomotic strictures and biliary fistulas and they can occur in different fashions, isolated or in combination. Graft source (cadaveric liver donor or living liver donor) has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. The endoscopic treatment using sphincterotomy, balloon dilation and insertion of biliary stents by ERCP (Endoscopic Retrograde Cholangiopancreatography) is used as an initial endoscopic approach to treat these complications. Objectives: To compare different endoscopic techniques to treat post-liver transplantation biliary strictures. Method: It was performed a systematic review of the literature and meta-analysis and the search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases until June, 2015. The meta-analysis was made using Review Manager, 2012 (RevMan) version 5.2 and OpenMetaAnalyst software and the calculations of the outcomes were made comparing the results from the included papers by using the difference in absolute risks, adopting a confidence interval of 95%. The studies were grouped comparing cadaveric liver donor versus living liver donor grafts; exclusive balloon dilation versus balloon dilation associated with plastic stents insertion; and plastic stents versus totally covered selfexpandable metal stents. The clinical outcomes were biliary stricture incidence, endoscopic treatment failure, stricture resolution, stricture recurrence and complications. Results: There were retrieved 1,100 articles. Ten clinical trials were analyzed, with just one Randomized Clinical Trial and nine Non-Randomized Clinical Trials, out of which seven were included in the meta-analysis. When comparing cadaveric liver donor transplantation to living liver donor transplantation, it was observed a decrease in the incidence of biliary strictures (p=0.0001), as well as in the technical failure rate of the endoscopic treatment (p=0.0009) and in the biliary stricture recurrence (p=0.03) in the cadaveric liver donor graft group. Two studies have compared the treatment of anastomotic biliary strictures after liver transplantation using balloon dilation exclusive to balloon dilation associated with the insertion of plastic stents, and no statistically significant differences in relation to endoscopic treatment failure, stricture recurrence or complications rates were observed. Only the clinical outcome complications had statistically significant result in a comparison between self-expandable metal stents versus plastic stents in the treatment of post-liver transplantation anastomotic biliary strictures (p=0.03). Conclusions: The treatment of post-liver transplantation anastomotic biliary strictures was equally effective when compared the use of self-expandable metal stents to plastic stents, but the use metallic stents was associated with a lower complication risk. The comparison between exclusive balloon dilation to balloon dilation associated with plastic stents presented similar results in relation to endoscopic treatment failure, complications and stenosis recurrence. The use of graft from cadaveric donor reduced the risk of biliary stenosis after liver transplantation and endoscopic treatment of biliary strictures in these patients were more effective when compared to biliary strictures after living liver donor transplantation

Page generated in 0.0678 seconds