• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 60
  • 60
  • 24
  • 22
  • 21
  • 21
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de diversos tipos de transferentes para prótese sobre implante

Andrade, Pâmela Cândida Aires Ribas de January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T17:57:10Z (GMT). No. of bitstreams: 1 327225.pdf: 4476966 bytes, checksum: 9afe1770eacf4599c637b70373a02e3d (MD5) Previous issue date: 2014 / A reprodução precisa da posição tridimensional (3D) do implante é um fator decisivo no estabelecimento de uma prótese ajustada e passiva. Vários fatores podem influenciar na precisão de uma moldagem de transferência sobre implante, e o desenho do transferente pode ser um deles. OBJETIVO: O objetivo deste estudo foi analisar quatro desenhos diferentes de transferente e comparar a precisão da moldagem de transferência de implantes unitários realizada por eles. MATERIAL E MÉTODOS: Um modelo metálico com quatro implantes hexágono externo foi desenhado e fabricado para a realização de vinte moldagens pela técnica da moldeira aberta. As moldagens foram realizadas com todos os tipos de transferentes (n=10) (transferente convencional [TC], transferente modificado com dois parafusos laterais [TMP], transferente modificado e sem parafusos laterais [TM], transferente modificado com resina acrílica [TR]); e duas situações (S1: n=20 e S2: n=20) de espaço 3D envolvendo dente e implante também foram avaliadas. As moldagens foram vazadas com gesso especial tipo IV e a precisão da posição 3D dos análogos foram avaliadas utilizando uma Máquina de Medir por Coordenadas (MMC). As medições (deslocamento linear, angular e rotacional) foram comparadas com as medições calculadas no modelo metálico. Os dados foram analisados estatisticamente pela análise de variância (ANOVA) e pelo teste t de student. RESULTADOS: Os resultados mostraram que (1) não existiu diferença estatisticamente significante entre os diferentes tipos de transferente para as duas situações analisadas; e (2) na comparação entre S1 e S2 o TC deslocou e rotacionou na S2. CONCLUSÃO: A partir dos resultados deste estudo foi possível concluir que, estatisticamente, o tipo de transferente não influencia na precisão da moldagem de implante unitário. No entanto, o TC, na S2, aonde existiu maior quantidade de material de moldagem, apresentou alteração de posição.<br>
12

Influência dos fatores locais na prevalência da peri-implantite ao redor de implantes pilares de próteses totais fixas

Schuldt Filho, Guenther January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T09:48:06Z (GMT). No. of bitstreams: 1 304705.pdf: 13802930 bytes, checksum: e7dccfe8d948661bd94ee0c5e41f1cf9 (MD5) / Objetivo: A proposta deste estudo foi avaliar a influência dos fatores locais na prevalência da peri-implantite em implantes osseointegrados instalados na mandíbula e maxila de pacientes que utilizavam próteses totais implantossuportadas. Materiais e Métodos: Foram examinados 27 pacientes (161 implantes) que apresentavam implantes cilíndricos, conexão do tipo hexágono externo (Conexão, São Paulo, Brasil), radiografias mensuráveis, informações dos prontuários preenchidas adequadamente e próteses totais implantossuportadas aparafusadas. Para este estudo, nenhum dos pacientes havia sido submetido à algum tipo de visita para manutenção da prótese e dos implantes no CEPID. Foram coletadas informações com relação ao sexo, idade, hábitos tabagistas, histórico de doença periodontal e saúde geral do paciente antes e após a instalação dos implantes. Com relação aos implantes, coletaram-se informações referentes às suas características tais como localização, posicionamento, tempo em função, quantidade de mucosa ceratinizada, profundidade de sondagem, índice de sangramento do sulco modificado, tipo de carga, índice de placa modificado, sangramento à sondagem, recessão e distância entre implantes. Com relação à prótese, os dados coletados estavam relacionados à dificuldade de higienização, tipo de pilar utilizado, presença ou não de pilar protético e extensão do cantiléver. Resultados: Dos 161 implantes analisados, 116 (72%) apresentaram-se sem peri-implantite enquanto que 45 (28%) apresentavam a doença. Houve significância estatística (p < 0.05) com relação à localização - implantes instalados na maxila possuem 2.98 vezes mais chances de apresentarem peri-implantite. Assim como os pacientes com idade ? 60 anos tem 3.24 vezes mais chances de apresentarem este tipo de doença. Outra análise com relevância estatística (p < 0.05) foi a de que se não obedecida a distância de no mínimo 3 mm entre implantes, as chances do surgimento da doença aumentam em 2.98 vezes. Não houve relevância estatística em nenhuma das outras análises. Conclusão: Conclui-se que pacientes com idade ? 60 anos possuem maior propensão à peri-implantite assim como implantes instalados na maxila e aqueles com distância entre sim < 3 mm. / Objective: The purpose of this study was to evaluate the influence of local factors in peri-implantis' prevalence in osseointegrated implants installed either on mandible or maxilla of patients using full-arch prostheses. Materials and Methods: There were examined 27 patients (116 implants) that presented cylindric implants with external hex connection (Conexão, São Paulo, Brasil), radiographs, charts filled correctly and screwed full-arch prostheses. For this study, none of the patients attended any follow-up visit until the data collection. There were collected information regarding gender, age, smoking habits, periodontal disease historic and patient's general health before and after implants installation. In relation to the implant, information obtained were about its characteristics, positioning, time in function, bleeding on probing, width of keratinized mucosa, modified sulcus bleeding index, type of loading, modified plaque index, probing depth, recession and distance between implants. Considering full-arch prostheses, the data collected were related with hygiene difficulty, type of abutment, abutment presence or not and cantilever extension. Results: Of the 161 implants analysed, 116 (72%) showed no peri-implantitis whereas 45 (28%) presented signs and symptoms of the disease. There was statistical significance (p < 0.05) regarding implant positioning - implants installed in the maxilla are 2.98 times more likely to develop the disease. As well as patients aged = 60 years old are 3.24 times more likely of presenting peri-implantitis. Another analysis with statistical relevance (p <0.05) was that implants with less than 3mm between them, are 3 times more likely of having peri-implantitis. There was no statistical relevance considering the other analyses. Conclusion: It can be concluded that patients aged = 60 years have more chances of presenting peri-implantitis as well as implants positioned in the maxilla and those installed with distance between them < 3 mm.
13

Critérios endodônticos e protéticos a serem considerados na confecção de núcleos metálicos fundidos em dentes unirradiculares

Kauling, Ana Elisa Colle January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T23:36:59Z (GMT). No. of bitstreams: 1 315071.pdf: 974822 bytes, checksum: b57bfddbe4aa266ecc80c92d03b8aab2 (MD5) / Grande parte de dentes tratados endodonticamente necessitam de retentores intrarradiculares para viabilizar a restauração protética. Em caso de amplas destruições coronais utilizamos os núcleos metálicos fundidos (NMF) como retentores, ainda que o sucesso desta técnica seja questionável. O objetivo deste estudo retrospectivo foi analisar radiograficamente características endodônticas e protéticas que estão envolvidos na confecção de NMF, a fim de identificar os motivos que levam ao insucesso da técnica. Para isso foram selecionadas 500 radiografias periapicais digitais de dentes unirradiculares restaurados com NMF onde se analisou através de um software de mensuração (ImageJ, EUA) critérios endodônticos e protéticos. Nos critérios endodônticos avaliou-se a presença de endodontia (94,6%)*, ausência de lesão (67,2%)*, comprimento do material obturador (78,6%)*, distância entre o material obturador e o vértice dentário (69,4%)* e ausência de espaços vazios no remanescente obturador (49,4%)*. Já nos critérios protéticos avaliou-se o comprimento do pino (25,6%)*, relação do pino com a crista óssea (85,4%)*, diâmetro do pino (78,4%)*, ausência de espaços vazios entre remanescente obturador e pino (41%)* e pino contíguo ao conduto radicular (88,4%)*. Concluiu-se que muitos critérios endodônticos e protéticos são negligenciados durante a confecção de NMF, nos levando a crer que não é a técnica que falha, mas sim a utilização inadequada da mesma.
14

Avaliação dos valores de destorque dos parafusos de titânio em pilares personalizáveis sobre implantes com hexágono externo

Medina, Carolina Enith Bullen January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2012 / Made available in DSpace on 2013-06-26T00:32:54Z (GMT). No. of bitstreams: 1 314860.pdf: 5500860 bytes, checksum: 1cbccbecc46b93e87b37e564d94aee77 (MD5) / Avaliar os valores de diferentes técnicas de destorque dos parafusos de titânio em pilares personalizáveis sobre implantes com hexágono externo. Metodologia: A amostra consistiu em 30 corpos de prova compostos pelo conjunto implante de hexágono externo (3,75mm de diâmetro e 10mm de comprimento), pilar personalizável e parafuso de titânio com encaixe para chave quadrada, que foram distribuídos aleatoriamente em três grupos (n=10): Grupo 1 - técnica convencional, com a aplicação de torque de 30N.cm; Grupo 2 - técnica descrita por Breeding e Dixon, com a aplicação de um primeiro torque de 30N.cm e, após 10 minutos, a aplicação de um novo torque com o mesmo valor inicial; e, Grupo 3 - técnica preconizada por Sella e Vasconcellos, com a aplicação de 30N.cm, mantendo o torque durante 20 segundos. Os corpos de prova foram fixados em uma base metálica e a mesma foi presa à base do equipamento universal de ensaio. Uma chave digital foi acoplada na célula de carga metálica, a qual possuía sensores que eram controlados por computador com o software ATMP2.2, a fim de controlar o valor do torque de 30N.cm a uma velocidade de 1N.cm/s, de acordo com a técnica de cada grupo experimental. Após 10 minutos da aplicação do torque, a máquina de ensaio foi programada para a aplicação do destorque, que foi realizado com os mesmos dispositivos utilizados para a aplicação do torque, com a mesma velocidade. Os valores de destorque dos três grupos foram submetidos à análise estatística pelo teste ANOVA e comparações individuais foram realizadas pelo teste HSD de Tukey. Resultados: As médias dos destorques encontrados foram de 27,95N.cm (DP ± 0,99) para o Grupo 1; 28,32N.cm para o Grupo 2 (DP ± 0,68); e, 26,89N.cm (DP ± 1,03) para o Grupo 3. Não houve diferença estatística entre os Grupos 1 e 2, porém, o Grupo 3 apresentou os menores valores de destorque, quando comparado com os outros grupos. Os valores de destorques obtidos em relação aos valores de torque foram menores para todos os grupos testados. Numericamente o grupo 2 apresentou valores maiores de destorque, porém, sem diferença estatística quando comparada com o grupo 1. O grupo 3 apresentou os menores valores de destorque, ou seja, menores valores de pré-carga / To evaluate the detorque values of titanium screws in customized pre-fabricated abutments with external hexagon implant. Methods: The sample consisted of 30 specimens formed by set of implant external hexagon (3.75 mm x 10mm ), customizable prefabricated abutment and titanium screw to fit square key, which were distributed randomly into three groups (n = 10): Group 1: the conventional technique, with the application of torque 30N.cm, Group 2: technique described by Dixon and Breeding, by applying a first torque 30N.cm and 10 minutes after the application of a new torque with the same initial value and Group 3: technique recommended by Sella and Vasconcellos, by applying 30N.cm, keeping the torque for 20 seconds. The specimens were fixed in a metal base and the same was attached to the base of the universal testing machine. Them a digital key was coupled to the metal load cell, which had sensors controlled by software computer ATMP2.2 in order to control the torque value of 30N.cm with a velocity of 1N.cm / s, according to the technique of each experimental group. After 10 minutes from application of torque, the test machine was programmed to implement detorque, which was performed with the same devices for the application of torque with the same speed. Detorque values of the three groups were statistically analyzed by ANOVA and individual comparisons were performed by Tukey's HSD test. Results: The mean destorques found were 27.95N.cm (SD ± 0.99) for Group 1; 28.32 N.cm for Group 2 (SD ± 0.68) and 26.89 N.cm (SD ± 1.03) for Group 3. There was no statistically significant difference between Groups 1 and 2, however, Group 3 showed lower values of detorque when compared with other groups. Conclusion: destorques values obtained were lower for all groups tested. Numerically group 2 have higher values of detorque, but no statistical difference when compared to group 1. Group 3 had the lowest values detorque, that is, lower preload.
15

Influência do tempo de exposição ao meio ambiente, da desinfecção química e da pigmentação sobre a estabilidade dimensional e a manutenção da reprodução de detalhes de silicones nacionais para uso em prótese facial /

Guiotti, Aimée Maria. January 2003 (has links)
Orientador: Marcelo Coelho Goiato / Abstract: The purpose of this study was to analyse the influence of time exposure to the environmental factors, chemical disinfection with 2% chlorhexidine-based solution and two distincts pigments about dimensional changing and maintenance of details of two silicones for use in maxillofacial prosthesis. Thirty specimens were fabricated for each silicone using a matrix, conformed closely to the specifications for nonaqueous, elastomeric dental impression materials established by the Revised American Dental Association n° 19 and the ISO 4823:1984. Specimens were separated in three groups: control (colourless), pigmented with commercial cosmetic (makeup powders) and pigmented with iron oxid. Specimens were analysed in a comparator microscopic (Carl Zeiss) and stereoscopic loupe. The readings were realized after polymerization of the specimens, and after 30 and 60 days, with and 157 without disinfection. The data were submited to the statistic analysis, by the Tukey's Test. The results indicated that all groups presented contraction; the chemical disinfection only changed the dimensional stability of the Silastic cosmetic pigmented group; the dimensional stability of Silastic was affected after 60 days of exposition in all groups. For the Brascoved silicone, the chemical disinfection only didn't have influence about dimensional stability in initial period; the exposition factor had influence about the dimensional stability of Brascoved in all periods and groups. The details were maintained in all specimens for both silicones, independent of the exposition time, of the pigments or disinfection. / Mestre
16

Influência do tempo de exposição ao meio ambiente, da desinfecção química e da pigmentação sobre a estabilidade dimensional e a manutenção da reprodução de detalhes de silicones nacionais para uso em prótese facial

Guiotti, Aimée Maria [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T18:35:15Z : No. of bitstreams: 1 guiotti_am_me_araca.pdf: 769780 bytes, checksum: 381f985ad016f2bce7728744d48fbe14 (MD5) / The purpose of this study was to analyse the influence of time exposure to the environmental factors, chemical disinfection with 2% chlorhexidine-based solution and two distincts pigments about dimensional changing and maintenance of details of two silicones for use in maxillofacial prosthesis. Thirty specimens were fabricated for each silicone using a matrix, conformed closely to the specifications for nonaqueous, elastomeric dental impression materials established by the Revised American Dental Association n° 19 and the ISO 4823:1984. Specimens were separated in three groups: control (colourless), pigmented with commercial cosmetic (makeup powders) and pigmented with iron oxid. Specimens were analysed in a comparator microscopic (Carl Zeiss) and stereoscopic loupe. The readings were realized after polymerization of the specimens, and after 30 and 60 days, with and 157 without disinfection. The data were submited to the statistic analysis, by the Tukey’s Test. The results indicated that all groups presented contraction; the chemical disinfection only changed the dimensional stability of the Silastic cosmetic pigmented group; the dimensional stability of Silastic was affected after 60 days of exposition in all groups. For the Brascoved silicone, the chemical disinfection only didn´t have influence about dimensional stability in initial period; the exposition factor had influence about the dimensional stability of Brascoved in all periods and groups. The details were maintained in all specimens for both silicones, independent of the exposition time, of the pigments or disinfection.
17

Avaliação da resistência à fratura de intermediários cerâmicos submetidos à ciclagem térmica

Kikko, Ricardo Figueiredo 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T23:39:24Z (GMT). No. of bitstreams: 1 280594.pdf: 2933774 bytes, checksum: ac1e624316f650eb7eb9d7e505b28d57 (MD5) / Este estudo teve como objetivo avaliar o comportamento in vitro de intermediários cerâmicos usinados por um sistema manual quanto a sua adaptação cervical e resistência à fratura. Vinte intermediários cerâmicos foram distribuídos aleatoriamente em 2 grupos (controle e experimental) com 10 intermediários cada. O grupo experimental foi submetido à termociclagem (500 ciclos). Para as mensurações do grau de adaptação foi construído um aparato onde os intermediários foram fixados aos implantes e cada parafuso recebeu um aperto com 20Ncm. As mensurações foram conduzidas em um microscópio eletrônico de varredura, totalizando 3 medições para cada intermediário, em um aumento de 700X. Após, os intermediários foram embutidos em cilindros de PVC com resina acrílica autopolimerizável, submetidos ao teste de resistência à fratura com auxílio de um dispositivo em um ângulo de 45º e velocidade de 1,0mm/min. Os resultados demonstraram não haver diferença estatisticamente significante quanto à adaptação cervical entre os grupos testados, embora, numericamente, os menores valores tenham sido observados no grupo controle. Os resultados encontrados para a resistência à fratura mostraram-se estatisticamente significantes, sugerindo que o envelhecimento térmico diminuiu a resistência à fratura dos intermediários testados. / Discos em resina composta, liga prata-paládio e liga de ouro tipo IV foram utilizados como substratos. Trinta discos cerâmicos foram obtidos nos sistemas IPS-Empress e IPS-Empress2 em 3 espessuras distintas (1,5; 2,0 e 2,5mm). Estes foram associados aos substratos citados e um espectrofotômetro foi utilizado para mensurar as coordenadas L* a* b*. As médias das coordenadas obtidas foram comparadas com as médias-padrão das cerâmicas testadas nas espessuras preconizadas pelo fabricante, resultando nas diferenças de cor entre estas comparações. Análise de variância (p<0,05) foi realizada para cada cerâmica testada, considerando as diferenças de cor (?E), luminosidade (?L*), e cor das coordenadas de cromaticidade a* e b* (?a* e ?b*). Os resultados demonstraram diferenças estatísticas em todas as condições testadas para as duas cerâmicas, sugerindo que, durante a escolha de um sistema cerâmico, tanto o substrato como a espessura de material cerâmico devem ser considerados, principalmente nos sistemas restauradores sem infra-estrutura cerâmica.
18

Dispositivo para instalação de pilares protéticos angulados em implantes dentários

Oderich, Elisa January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-23T00:23:17Z (GMT). No. of bitstreams: 1 252697.pdf: 5504002 bytes, checksum: 9ece4ac202f0a0112aee5c178f67c5f2 (MD5) / A correta instalação de pilares protéticos angulados em implantes dentários é um procedimento clínico complexo e fundamental para o sucesso das próteses implantossuportadas. Visando simplificar tal procedimento foi desenvolvido um adaptador para este tipo de pilar. Objetivou-se com este estudo avaliar o desempenho deste novo dispositivo para instalação de pilares angulados. Dois métodos de instalação, com e sem o uso do adaptador, foram avaliados quanto ao tempo despendido para a instalação dos pilares, bem como as respostas oriundas do preenchimento de questionário específico por 40 profissionais experientes. O pilar angulado, entre os demais componentes protéticos, foi considerado aquele mais difícil de ser instalado. O tempo de instalação do pilar angulado com a utilização do adaptador é equivalente a 56,1% do tempo desprendido para realizar tal procedimento de maneira convencional. O uso do adaptador mostrou facilitar e reduzir significativamente o tempo de instalação dos pilares angulados. One of the complex clinical procedure on implant therapy is to install angled abutments. In order to simplify such procedure an appliance was developed by Dental Implant Research and Study Center - CEPID in Federal University of Santa Catarina - UFSC. The aim of this article was to assess the performance of this new device at installing pre-manufactured angled abutments. Two methods of angled abutment placement were tested in mannequin through time control by 40 experienced professionals. Among all the prosthetic components available, the angled abutment is the most difficult to be installed The angled abutment placement time with the appliance is 56.1% of that time necessary to realize this procedure by the conventional method. The appliance did facilitate and reduce angled abutment placement time.
19

Avaliação das próteses fixas totais sem estrutura metálica, implantossuportadas com carga imediata

Cunha, Hiron Andreaza da 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2008 / Made available in DSpace on 2012-10-24T00:37:30Z (GMT). No. of bitstreams: 1 269710.pdf: 1134622 bytes, checksum: d50293ec4a3817531c6d02ee4992e1b5 (MD5) / Por meio deste estudo foi analisado o comportamento clínico das próteses fixas implantossuportadas sem infra-estrutura metálica submetidas à carga imediata, como tratamento definitivo, em dez pacientes que receberam cinco implantes na mandíbula entre os foramens mentual, somando um total de 50 implantes, cada paciente recebendo uma prótese fixa de 12 elementos sem infra estrutura metálica e uma prótese total superior. Este estudo avaliou ao mesmo tempo a estabilidade inicial e secundaria dos implantes por um período de 24 meses, por meio do Osstell, aparelho que afere a estabiliade do implante por meio de freqüência de ressonância. Os resultados da análise descritiva apresentaram em média uma estabilidade inicial de 71.76 ISQ (Quociente de estabilidade do implante), a estabilidade secundária em média após 6 meses foi de 69,35 ISQ, 12 meses foi de 70.14 ISQ e 24 meses foi de 70.10 ISQ (Quociente de estabilidade do implante), indicando que os implantes estavam estáveis após 24 meses em função. Os resultados são favoráveis aos itens avaliados, não houve fraturas das próteses, não houve afrouxamento ou fraturas dos parafusos de retenção, não houve perda de implantes de nenhum dos cinqüenta implantes instalados, demonstrando ser viável o uso dessa técnica. / This study analyzed the clinical behavior of the implants, submitted to a immediate loading with fixed prosthesis implantsupported without a metallic infrastructure by means of Osstell, for a period of twenty-four months, in ten patients, who received five implants in the mandible between the mentonian foramens, with a total of 50 implants, each patient received a fixed prosthesis of 12 elements without a metallic structure and a superior total prosthetics. During this period it was also evaluated the clinical behavior of the prosthesis, as to the resistance to fracture of the acrylic resin, the unscrewing and fracture of the retention screws of the prosthesis in the masticating function. The results of the descriptive analysis presented an initial stability of 71.76 ISQ (Implant Stability Quotient). The secondary stability, after 6 months, was of 69,30 ISQ; 12 months, was of 68.04 ISQ; after 24 months, was of 69.48 ISQ, indicating that the implants were stable after 24 months of function. There were no losses of implants during this period. The results were favorable to the evaluated items, the initial and secondary stability remained in normal values, and there were no fractures of the prosthesis, no loosening or fractures of the retention screws, there were no losses of the fifty implants installed, during the period of study of 24 months, showing a viable use of this technique.
20

A percepção do cirurgião dentista quanto ao tipo de infraestrutura utilizado em próteses unitárias implantossuportadas

Melo, Eduardo Vilain de January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T09:41:12Z (GMT). No. of bitstreams: 1 304953.pdf: 1294497 bytes, checksum: d1f4940f51ab0956e463d12142ccb9a6 (MD5) / Objetivos: Avaliar a percepção de cirurgiões-dentistas pós-graduados nas áreas de periodontia, implantodontia, dentística restauradora e prótese dentária, em diagnosticar qual tipo prótese (cerâmica ou metalocerâmica) foi utilizada na reabilitação protética, em implantes unitários na região dos incisivos laterais superiores. Materiais e Métodos: Cinco implantes unitários na região do incisivo lateral superior foram restaurados, com dois tipos de próteses parafusadas diretamente sobre o implante (próteses metalocerâmica e cerâmica). Foram realizadas fotografias de ambas as próteses em posição, totalizando 10 imagens, que foram apresentadas a 40 avaliadores. Estes foram divididos em 5 grupos, de acordo com a área de especialidade (Pós-graduados em Dentística/Prótese Dental ou Periodontia/Implantodontia) e tempo de formado em odontologia (maior ou menor que 10 anos). Os avaliadores tinham de responder se a prótese era: cerâmica, metalocerâmica ou que não sabiam dizer. Resultados: Os Grupos 1, 3, 4 e 5, falharam em responder corretamente (P > 0.05), qual tipo de prótese foi apresentada, se mantendo, de maneira geral, dentro de um padrão aleatório de acerto. No Grupo 2 (Pós graduados em Periodontia/Implantodontia), em relação as próteses metalocerâmicas, o índice de acerto foi de 35,6% (P = 0.009), abaixo do índice aleatório, apresentando um resultado falso positivo. Conclusão: Os avaliadores foram incapazes de diferenciar de maneira significativa, qual tipo de prótese era cerâmica ou metalocerâmica nos 10 casos apresentados, comprovando assim, a hipótese de que as próteses metalocerâmicas ou cerâmicas são indistinguíveis ao olho humano, nas situações propostas pela metodologia deste estudo. / Objective: To evaluate the perception of postgraduates dentists in the areas of periodontics, implant dentistry, restorative dentistry and prosthodontics, to diagnose what type prosthesis, metal-free or porcelain-fused-to-metal (PFM), was used in the prosthetic rehabilitation of single-tooth implants in the lateral maxillary incisor region. Materials and Methods: Five single-tooth implants in the maxillary lateral incisor region were restored with two types of prostheses (PFM prosthesis and metal-free) directly screwed over the implant. Photographs were taken of both prostheses in position over the same the implant, totaling 10 images, which were presented to 20 evaluators. The evaluators were divided into five groups according to their area of expertise (Postgraduates in Periodontics/Implantology or Restorative Dentistry/Prosthodontics) and time of graduation in dentistry (over or under 10 years). The evaluators had to answer whether the prosthesis was: metal-free, PFM or could not tell. Results: Groups 1, 3, 4 and 5 failed to respond correctly (P > 0.05), which type of prosthesis was presented to him, remaining in a random pattern of accuracy. In Group 2 (Postgraduates in Periodontics/Implantology), in relation to metal-free prostheses, the accuracy rate was 35.6% (P = 0.009), below the random index, showing a false-positive result. Conclusion: The evaluators were unable to significantly differentiate which type of prosthesis, being it free of metal or PFM, was used in the 10 presented cases, thus, proving the hypothesis that PFM or metal-free prostheses are indistinguishable to the human eye in the situation proposed by the methodology of this study.

Page generated in 0.0624 seconds