• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1438
  • 201
  • 65
  • 65
  • 65
  • 64
  • 40
  • 15
  • 15
  • 15
  • 11
  • 10
  • 7
  • 2
  • 2
  • Tagged with
  • 1671
  • 625
  • 519
  • 402
  • 369
  • 313
  • 276
  • 274
  • 234
  • 210
  • 184
  • 163
  • 136
  • 136
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Influência do tipo de luz polimerizadora e nível de término cervical do preparo cavitário no comportamento da cimentação adesiva

Machry, Lessandro January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-23T02:41:26Z (GMT). No. of bitstreams: 1 241455.pdf: 3402091 bytes, checksum: f6574fa62e5b8a7b7053f1085adf9e60 (MD5) / O objetivo da pesquisa, in vitro, foi comparar uma unidade de fotoativação à base de LEDs, com uma unidade convencional halógena no selamento marginal em restaurações indiretas de compósitos. Na face mesial, o término ficou em nível da junção amelo-cementária, enquanto que na face distal ficou 2mm acima. OS resultados mostraram que para o fator margem houve diferença estatística, ocorrendo maior microinfiltração em dentina. Concluiu-se que o selamento marginal em restaurações indiretas de compósitos não foi influenciado pelas unidades fotopolimerizadoras e que as margens localizadas em dentina tiveram uma maior microinfiltração.
192

Estudio comparativo in vitro, al microscopio electrónico de barrido, de la interfase diente-restauración al utilizar un cemento de resina autoadhesivo y un cemento de resina con sistema adhesivo de grabado ácido total

Cortés Pérez, Mario January 2008 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / El presente trabajo realizó un estudio comparativo, in vitro, al Microscopio Electrónico de Barrido, para evaluar si existen diferencias al comparar la interfase generada entre el diente y restauraciones indirectas de resina compuesta, cementadas con el cemento de resina con sistema adhesivo de grabado ácido total RelyX Arc (3M ESPE) y el nuevo cemento de resina autoadhesivo RelyX U100 (3M ESPE). Se utilizaron terceros molares humanos libres de caries, los que una vez extraídos fueron colocados en una solución de suero fisiológico con formalina al 2%. En la corona de cada diente, dos milímetros sobre el límite amelo-cementario, se realizaron dos cavidades operatorias expulsivas de dimensiones estandarizadas, una en la cara vestibular y la otra en la cara lingual o palatina. Luego, sobre las cavidades se confeccionaron restauraciones indirectas con resina compuesta Z 100 (3M/USA.), las que fueron polimerizadas con una lámpara de luz halógena convencional (XL 3000, 3M/ESPE). Una vez terminadas las incrustaciones se arenaron en su cara interna con óxido de alúmina ≤ 40 μm. Posteriormente, en cada diente se cementaron dos restauraciones, una con el cemento autoadhesivo Relyx U100 (3M), y otra con el cemento de resina Relyx Arc (3M), siguiendo las indicaciones del fabricante para la utilización de cada cemento. Luego, con un disco metálico diamantado montado en un microcomotor se trozaron los dientes con las restauraciones cementadas hasta obtener cortes sagitales y transversales los que pasaban por la parte media de las restauraciones dejando expuesta la interfase diente restauración. A continuación, las muestras fueron sometidas a los procesos de secado y metalizado, necesarios para poder observarlas en el Microscopio Electrónico de Barrido Seis DSM 940. A través del MEB se observó la interfase diente restauración de las muestras, analizando el comportamiento de ambos cementos en su unión a esmalte y a dentina. Se determinó el grosor de película en micrones y se analizó la adaptación, es decir la presencia o ausencia de brechas entre el cemento y los tejidos dentales. Se encontraron diferencias entre los cementos al medir el grosor de película, tanto en esmalte como en dentina. El cemento RelyX Arc mostró un grosor aproximado de 50 μm, mientras que RelyX U100 presentó grosores de película que variaron de 5,26 a 32,7 μm. En la adaptación al esmalte se observaron diferencias entre ambos cementos. El cemento Relyx Arc logró una unión a esmalte sin presencia de brechas en la interfase entre el cemento y el tejido dental. En contraste el cemento RelyX U100 se mostró muy irregular en su unión con el esmalte, se presentaron tres situaciones a lo largo de la línea de cementación, sectores en los que el cemento se unió al esmalte sin presencia de brechas en la interfase esmalte-cemento, sectores en los que el cemento no se unió al esmalte observándose una brecha entre el cemento y el esmalte, y por último, la situación más común observada a lo largo de la línea de cementación fue una unión intermitente entre el cemento y el esmalte. En la adaptación de los cementos a dentina, si bien los cementos presentaron comportamientos diferentes, debido a que RelyX Arc, a diferencia de RelyX U100 formó tapones de resina dentro de los túbulos dentinarios, esto no constituye una diferencia relevante en la adaptación a dentina entre ambos cementos, ya que ambos se unieron a la dentina sin presencia de brechas en la interfase.
193

Microfiltración marginal de restauraciones indirectas de resina compuesta cementadas con resina fluida con sistema de adhesivo de grabado total versus sistema de autograbado

Leiva Büchi, Marisol Beatriz January 2007 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Se midió experimentalmente in vitro la microfiltración alcanzada en 80 incrustaciones de resina compuesta cementadas con resina fluida utilizando un sistema autograbante (Go!, SDI, Australia) versus un sistema de grabado total (Stae, SDI,Australia) realizando un baño de termociclado de 80 ciclos con una solución de azul de metileno al 1%. Las muestras fueron selladas previamente y fueron puestas en una estufa conservando el 100% de humedad con el fin de simular las condiciones de la cavidad bucal. Posteriormente las muestras fueron cortadas en sentido vestíbulo lingual o palatino, para ser observadas bajo un microscopio óptico, obtener porcentajes y luego promedios de microfiltración para ambos grupos. Los resultados obtenidos fueron analizados estadísticamente mediante el t-test de Student obteniéndose diferencias significativas entre los grupos de estudios. Se concluye que ningún grupo presentó resistencia a la penetración del marcador de microfiltración, sin embargo el grupo que utilizó un sistema adhesivo autograbante demostró tener valores significativamente mayores de microfiltración que el grupo que utilizó el sistema convencional.
194

Influência dos fotoativadores PAC e QTH na polimerização de resina composta e na geração de calor

Berthold, Telmo Bandeira January 2005 (has links)
O objetivo deste estudo foi avaliar e comparar in vitro o desempenho dos fotoativadores Apollo® 95E /DenMed Technologies, com luz xênon (arco de plasma - PAC), e o Curing Light® XL 3000 /3M-Unitek, com luz halógena (convencional - QTH), comparando-se, desta forma, um fotoativador de alta intensidade de luz (PAC) com um convencional (QTH). A efetividade dos aparelhos foi verificada pelo grau de polimerização apresentado pela resina composta (Transbond™XT/3MUnitek), avaliado em espectrofotometria por infravermelho e pela análise de microdureza Knoop. Os tempos de ativação para a fonte PAC foram um, dois e três segundos e, para a fonte QTH, foram 10, 20 e 30 segundos, buscando-se avaliar a equivalência, ou não, dos diferentes tempos das diferentes unidades fotoativadoras. Foram usadas matrizes metálicas circulares, que receberam a resina para posterior polimerização. Para cada tempo de ativação, para cada aparelho e para cada teste, foi fotoativada a resina composta de cinco corpos-de-prova. Foi avaliada, também, a temperatura no extremo distal do condutor de luz de cada aparelho, nos seus respectivos tempos predeterminados, colocando-se justaposto, à ponta do fotoativador, o sensor do dispositivo de aferição Sekundenthermometer/GTH 1160 – Phywe. Os resultados obtidos foram submetidos ao teste não-paramétrico Kolmogorov-Smirnov, à Análise de Variância (ANOVA) e ao teste de comparações múltiplas de Tukey. Os resultados da espectrofotometria apontaram diferença estatística significativa entre os grupos estudados. O grupo QTH alcançou as maiores médias e diferiu do grupo PAC (p=0,01). O ensaio de microdureza Knoop também apresentou resultados que apontaram a existência de diferença estatística significativa entre os grupos estudados, tendo o grupo QTH alcançado as maiores médias (p=0,01). A avaliação da temperatura igualmente apresentou diferença estatística significativa entre os grupos estudados (p=0,01), sendo que o grupo QTH atingiu as maiores médias. Com base na metodologia empregada e na análise dos dados obtidos no presente estudo, pode-se concluir que o grau de polimerização da resina composta e a temperatura no extremo distal do condutor de luz apresentaram diferença estatística significativa com o uso das unidades fotoativadoras Apollo® 95E (xênon) e Curing Light® XL 3000 (halógena) nos respectivos tempos predeterminados (p=0,01), ficando sempre, com as maiores médias, o aparelho convencional com luz halógena.
195

Grau de conversão, temperatura de transição vítrea, microdureza e resistência ao impacto de uma resina acrílica quimicamente ativada submetida a diferentes condições de polimerização

Machado, Cintia de Vasconcellos January 2005 (has links)
O objetivo deste estudo foi avaliar a influência de diferentes condições de polimerização sobre: microdureza Knoop, resistência ao impacto, grau de conversão e temperatura de transição vítrea (Tg) de uma resina acrílica quimicamente ativada (Jet - Artigos Odontológicos Clássico Ltda.). O material foi polimerizado de acordo com as seguintes condições: grupo 1, as amostras foram polimerizadas em contato com o ar, durante 1h, sob temperatura e pressão ambiente; grupo 2, após a polimerização da resina em contato com o ar, durante 1h, sob temperatura e pressão ambiente, a mesma foi submetida a um ciclo adicional de aquecimento em forno de microondas, durante 3 min, a 500W; grupo 3, as amostras foram polimerizadas em água, sob pressão de 20 psi, em uma temperatura de 50°C, durante 15 minutos. Para o ensaio de microdureza Knoop, foram confeccionados sete corpos-de-prova, para cada um dos três grupos experimentais. O corpo-de-prova consistiu de uma placa de resina acrílica quimicamente ativada, com grampos, simulando aparelhos ortodônticos removíveis. Dos sete corpos-de-prova, de cada grupo, dois também foram utilizados para a determinação do grau de conversão e Tg, através da Calorimetria Exploratória Diferencial (DSC). Para o ensaio de resistência ao impacto, foram confeccionados 12 corpos-de-prova para cada grupo, com dimensões de 64,00x10,00x3,20mm. Os resultados mostraram diferenças entre os grupos, através da ANOVA e do teste de Tukey (p ≤ 0,01), apresentando maiores valores de microdureza para o grupo 3, seguido dos grupos 2 e 1. Para o ensaio de resistência ao impacto, os valores obtidos para as amostras do grupo 3 foram superiores aos demais grupos, não havendo diferença estatística entre os grupos 1 e 2 O grau de conversão e Tg foram avaliados de forma descritiva, apresentando um padrão de comportamento coerente com as demais propriedades, ou seja, o grupo 3 apresentou valores mais altos de grau de conversão e Tg, seguido pelos grupos 2 e 1. Os resultados deste trabalho indicam que o melhor comportamento clínico poderá ser esperado do grupo submetido à polimerização em água a 50°C, sob pressão de 20 psi (grupo 3), seguido do grupo 2 (com ciclo adicional em microondas) e, por fim, pelo grupo 1 (polimerizado ao ar).
196

Avaliação de resinas de troca iônica para emprego na hidrometalurgia de minérios auríferos

Kautzmann, Rubens Muller January 1999 (has links)
O emprego de resinas trocadoras de íons na adsorção de ouro dissolvido em soluções cianetadas, típicas de processos hidrometalúrgicos de cianetação de minérios auríferos foi avaliada para alguns tipos de resina com propriedades base fraca de estrutura macroporosas e fibrosas. Três tipos de resinas receberam um maior aprofundamento de estudo em referência ao desempenho de extração do Au(CN)2- e cianocomplexos de Ag, Ni, Cu, Fe e Hg: (1) resinas Hypersol Macronet produzidas pela Purolite, Inglaterra, (2) resina Fiban (AK22) em base a material fibroso tecido na forma de manta produzidas por Ecofil-Delco, Bielorussia, e (3) resina em base a grupo piperazina (em fase de desenvolvimento) sintetizada nos laboratórios do Departamento de Química Orgânica do Instituto de Ciências Weizmann, Israel. Este trabalho contém ao final alguns resultados iniciais dos trabalhos de avaliação com resinas impregnadas, resinas protótipos e resinas comerciais, com características e propriedades potencialmente de interesse à hidrometalurgia de minérios auríferos. As principais características e propriedades avaliadas foram: pKa, carregamento, seletividade, cinética e eficiência de eluição. Os testes foram realizados em escala de laboratório, utilizando predominantemente soluções sintéticas e lixívias minerais de amostras de minérios brasileiros. Os resultados deste estudo mostraram a potencialidade do uso de resinas base fraca para extração de ouro em solução principalmente quanto aos aspectos de carregamento, seletividade e eluição. Estes comportamentos podem ser determinados pela combinação de fatores, tais como: a) propriedade ácido-base do grupo funcional, b) balanço do grau de hidrofobicidade da matriz polimérica e c) alta área superficial da resina. Não foram obtidos comportamentos ideais de extração de ouro frente a pH moderadamente alcalino, mas os resultados se aproximaram àqueles esperados quando empregados grupo funcional de alto pKa, como para a resina-piperazina ou guanidina. Por outro lado ganhos de eficiência em capacidade de carregamento em ambientes alcalinos podem ser alcançados com a introdução de grupos amina base forte, como observado para resinas Hypersol Macronet. A resina fibrosa AK22 demonstrou interessante comportamento seletivo em função da faixa de pH na extração dos cianocomplexos de ouro (pH<10) e mercúrio (pH>11). / The use of ion exchange resins for gold recovery from typical cyanide leach solutions in hydrometallurgy process was evaluated for some weak base resins with macroporous and fibrous structure. More extensive investigations were carried out on three types of resins, respect their performance of Au(CN)2- and cyanide complexes of Ag, Ni, Cu, Fe e Hg extraction: (1) Hypersol Macronet resin made from Purolite, England, (2) Fibrous resin Fiban (AK22) textile form as mantle made from Ecofil-Delco, Bielorussian, and (3) resin with piperazin functional group (development stage) sintetized in the laboratory of Department of Organic Chemistry of Weizmann Cientific Institute, Israel. This work also presents some initial results about the evaluation in other resins with potential interest to gold hydrometallurgy. To evaluate which resins might show promising results determined characteristics and proprieties were measured as: pKa, loading, selectivity, kinetic and elution efficiency. For experimental measurement, small-scale dynamic contacts between resin and metal-cyanide complexes were effected, used both synthetic and real cyanide solutions, the last obtained from the leaching of a gold mineral ore from Brazil. Resins with a weak base functionality show promising results when applied to the extraction of goldcyanide from cyanide media mainly in terms of loading, separation and stripping factors. These behaviours can be determined by the combination of factors, among then the following could be pointed out: a) the suitable functional group’s acid-base properties, b) the balanced degree of hydrophobicity of the polymer matrix and c) the high surface area of the resin. The best results of gold extraction weren’t yet achieved in moderately alkaline pH values, but results are close to those expected when functionalised with groups as piperazine or guanidine extracting, are empoyed. n the other hand, gains in loading efficiency, independently of pH, were reach with the introduction a few percent the strong amino groups in resin, as Hypersol Macronet. Fibrous resin AK22 presented the interesting selectivity behaviour between gold and mercury cyanide where the gold was extract at pH<10 and when the eluted to gold had begin the mercury was extract in pH>11.
197

Análisis comparativo "in vitro" del comportamiento físico-mecánico de restauraciones de resina compuesta realizadas con el adhesivo One Coat SL Bond ® vesus el adhesivo One Coat SE Bond ®

Boggioni Cortez, Claudio Ettore January 2007 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Autor no autoriza el acceso a texto completo de su documento / Se realizó un estudio comparativo “in vitro” con el fin de evaluar y comparar la microfiltración marginal de dos sistemas adhesivos dentinarios: un adhesivo dentinario que utiliza el grabado ácido total de la cavidad operatoria (One Coat Bond SL (Coltène/Whaledent®) y otro que es un sistema adhesivo autograbante (One Coat Bond SE (Coltène/Whaledent®). Para ello se usaron 10 terceros molares sanos, recientemente extraídos a los cuales se les realizó 2 cavidades operatorias estandarizadas ubicadas en el tercio medio de las caras vestibular y lingual/palatino. Posteriormente se obturaron las cavidades con una misma resina compuesta (Synergy®), utilizando distintos sistemas adhesivos, siguiendo las indicaciones del fabricante. En las cavidades linguales o palatinas se utilizó el sistema adhesivo de autograbado y en las cavidades vestibulares el sistema adhesivo de grabado ácido convencional. Realizadas las restauraciones las muestras se conservaron durante una semana a 37ºC +/- 1ºC y 100% de humedad. Con el fin de visualizar el grado de microfiltración marginal, los molares en estudio fueron sometidos a un proceso de termociclado en una solución acuosa de azul de metileno al 1% durante 100 ciclos. Posteriormente las muestras fueron cortadas transversalmente pasando por las dos cavidades para exponer la interfase diente-restauración. Las obturaciones seccionadas se observaron en el microscopio óptico para medir el grado de microfiltración del colorante en la interfase diente-restauración. Los resultados obtenidos en porcentajes de los grupos de prueba se sometieron a un análisis estadístico, encontrándose diferencias estadísticamente significativas a favor de las restauraciones en que se utilizó el adhesivo con técnica de grabado ácido convencional por sobre las restauraciones en que se usó el adhesivo Autograbante. Posteriormente se realizó otro estudio in vitro con el fin de avaluar y comparar la resistencia adhesiva de resinas compuestas adheridas a superficies dentarias con un adhesivo que utiliza técnica de grabado ácido total One Coat Bond SL (Coltène/Whaledent®) y un adhesivo con técnica de autograbado One Coat Bond SE (Coltène/Whaledent®), dichas resistencias fueron evaluadas frente a fuerzas de cizallamiento. Para esto se utilizó una muestra de 12 molares humanos recién extraídos, libres de caries, sobre los cuales se confeccionaron los cuerpos de prueba; para ello se cortó cada pieza dentaria en sentido vestíbulo palatino o lingual, obteniéndose de esta manera dos mitades a las cuales se les eliminó la porción radicular y los restos de cámara pulpar para proporcionar una superficie amelodentinaria lisa y aplanada. Sobre ésta se fabricó un cilindro de resina de dimensiones establecidas previo acondicionamiento de la superficie. Luego, en la superficie del esmalte se confeccionó un cono de resina el cual fue adherido con técnica adhesiva convencional, y finalmente se realizó a cada cuerpo de prueba un mango de acrílico de autocurado para poder ser posicionados en el dispositivo de la máquina de ensayos universal INSTRON®. Los cuerpos fueron sometidos a la prueba de resistencia adhesiva a las fuerzas de cizallamiento en dicha máquina. Los resultados fueron transformados de Kilogramos- Fuerza a Mpa, los cuales fueron sometidos al análisis estadístico mediante Test Student, encontrándose diferencias estadísticamente significativas entre ambos grupos. Se concluyó que las restauraciones de resina compuesta realizadas con el adhesivo con técnica de grabado ácido total One Coat Bond SL presentó los mayores valores de resistencia adhesiva al cizallamiento al compararlo con las restauraciones de composite realizadas con el sistema adhesivo autograbante One Coat Bond SE.
198

Análisis comparativo in vitro del sellado marginal de restauraciones de resina compuesta realizadas con un adhesivo de grabado y lavado versus un adhesivo autograbante de 7a. generación de la misma marca comercial

Nazar Osman, Jaime Andrés January 2007 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / En el presente estudio se realizó un análisis comparativo in vitro con el fin de evaluar y comparar la microfiltración marginal de dos adhesivos dentinarios: un adhesivo dentinario que utiliza el grabado ácido total de la cavidad operatoria (Tetric N Bond®) y otro que es un sistema adhesivo autograbante de 7° generación (AdheSE One®) (ambos de Ivoclar Vivadent®). Para esto se utilizó una muestra de 21 molares humanos sanos recientemente extraídos, libres de caries, a los cuales se les realizó 2 cavidades operatorias estandarizadas ubicadas en el tercio medio de las caras vestibular y lingual/palatino. Posteriormente se obturaron las cavidades con una misma resina compuesta (Tetric N Ceram® color A1, Ivoclar Vivadent®), utilizando distintos sistemas adhesivos, siguiendo las indicaciones del fabricante. En las cavidades linguales o palatinas se utilizó el sistema adhesivo de autograbado y en las cavidades vestibulares el sistema adhesivo de grabado ácido convencional. Realizadas las restauraciones las muestras se conservaron durante una semana a 37°C +/- 1°C y 100% de humedad. Con el fin de visualizar el grado de microfiltración marginal, los molares en estudio fueron sometidos a un proceso de termociclado en una solución acuosa de azul de metileno al 1% durante 100 ciclos. Posteriormente las muestras fueron cortadas transversalmente pasando por las dos cavidades para exponer la interfase diente-restauración. Las obturaciones seccionadas se observaron en el microscopio óptico para medir el grado de microfiltración del colorante en la interfase diente-restauración. Los resultados obtenidos en porcentajes de los grupos de prueba se sometieron a un análisis estadístico, encontrándose diferencias estadísticamente significativas a favor de las restauraciones en que se utilizó el adhesivo con técnica de grabado ácido convencional de 5° generación por sobre las restauraciones en que se usó el adhesivo autograbante de 7° generación.
199

Análise da contaminação microbiana de dispositivos acrílicos confeccionados em laboratórios de prótese dentária / Analysis of microbial contamination of device acrylic manufactured in dental laboratories

Temóteo, Guilherme de Alencar January 2014 (has links)
TEMÓTEO, Guilherme de Alencar. Análise da contaminação microbiana de dispositivos acrílicos confeccionados em laboratórios de próteses dentárias. 2014. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2014. / Submitted by denise santos (denise.santos@ufc.br) on 2014-07-21T11:40:44Z No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-07-21T11:50:50Z (GMT) No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) / Made available in DSpace on 2014-07-21T11:50:50Z (GMT). No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) Previous issue date: 2014 / The possible presence of potentially pathogenic microorganisms in denture newly arrived from prosthetic laboratories should be considered. This study evaluated the level of bacterial and fungal contamination of specimens of acrylic resin made in 14 dental laboratories registered with the Regional Council of Dentistry of Ceará, Fortaleza. Each laboratory was asked to fabricate 10 specimens of acrylic resin, from standard models of sterile silicone addition, unaware of the research objectives. Specimens received from laboratories were placed in individual tubes containing BHI broth, incubated at 37°C for 48 hours and then removed, washed and placed in sterile saline and stirred for microbial detachment. The suspension obtained was diluted (1:100, 1:1000) and plated on blood agar plates, and Sabouraud Dextrose Agar and Agar HiCrome ICU by incubation for 48 hours at 37°C. The number of colony forming units (CFU) bacterial and fungal viable was obtained, besides the identification and quantification of some species of bacteria, comparing the laboratory by means of the Kruskal-Wallis and Dunn (α = 0.05) tests. There was contamination originating from all laboratories analyzed, with a mean CFU counts of 101438 bacteria and 71047 fungi. Pseudomonas spp was the most prevalent microorganism identified (p < 0.05). It was concluded that there is a risk of contamination with potentially pathogenic bacteria and fungi in prosthetic devices newly arrived from dental laboratories. / A possível presença de microorganismos potencialmente patogênicos em próteses dentárias recém-chegadas dos laboratórios protéticos deve ser considerada. Este estudo avaliou o nível de contaminação bacteriana e fúngica de espécimes de resina acrílica confeccionados em 14 laboratórios de prótese dentária, inscritos no Conselho Regional de Odontologia do Ceará, na cidade de Fortaleza. Cada laboratório foi solicitado a confeccionar 10 espécimes de resina acrílica, a partir de modelos padronizados de silicona de adição estéreis, desconhecendo os objetivos da pesquisa. Os espécimes recebidos dos laboratórios foram colocados em tubos individuais contendo BHI caldo e incubados a 37°C por 48 horas e, em seguida, removidos, lavados, colocados em solução salina estéril e agitados para desprendimento microbiano. A suspensão obtida foi diluída em 1:100, 1:1000 e semeada em placas com Ágar Sangue, Sabouraud Dextrose Ágar e HICrome UTI Ágar®, para incubação por 48 horas a 37°C. Foi obtido o número de unidades formadoras de colônias (UFC) bacterianas e fúngicas viáveis, além da identificação e quantificação de algumas espécies de bactérias, comparando-se os laboratórios por meio dos testes de Kruskall-Wallis e Dunn (α=0.05). Houve contaminação advinda de todos os laboratórios analizados, com uma contagem de UFC média de 101438 de bactérias e 71047 de fungos. Pseudomonas spp foi o microorganismo a mais prevalente identificado (p<0,05). Foi concluido que existe risco de contaminação por bactérias potencialmente patogênicas e fungos em dispositivos protéticos recém chegados dos laboratórios.
200

Avaliação da microdureza e cor de cimentos resinosos inseridos em diferentes substância e PH

Santos Neto, Cássio dos January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:18:07Z (GMT). No. of bitstreams: 1 329721.pdf: 4532649 bytes, checksum: 18cb60d2e542b0328ffc57d72577675e (MD5) Previous issue date: 2014 / O objetivo deste estudo in vitro foi de avaliar a microdureza e a alteração da cor de quatro cimentos resinosos, imersos em seis diferentes substâncias e por diferentes períodos de tempo. Sessenta discos de cimentos resinosos, foram confeccionados (6mm x 2mm), para cada tipo de cimento (Rely - X Veneer (R), Rely-X U200 (U) , Multilink (M) e o Variolink Veneer (V)) e polidos com ponta de borracha de passo único (Optrapol, Ivoclar Vivadent) por 30 s, em seguida armazenados por 24 hrs em água destilada. A subdivisão foi realizado em 6 subgrupos (n=10), de acordo com a solução imersora, a uma temperatura de 37ºC: Grupo R-1(Rely-X Veneer), Grupo M-1 (Multilink), Grupo V-1 (Variolink Veneer) e o Grupo U-1(Rely-X U200), foram armazenadas em água destilada (controle (1)). Grupo R-2, M-2, V-2 e U-2 em coca (2). Grupo R-3, M-3, V-3 e U-3 em vinho (3), Grupo R-4, M-4, V-4 e U-4 em suco cítrico (4), Grupo R-5, M-5, V-5 e U-5 em whisky (5) e Grupo R-6, M-6, V-6 e U-6 embebida energética (6). Os espécimes foram mesurados imediatamente, 24 hrs, 7, 14 e 90 dias, por um microdurometro (HMV 2, Shimadzu - Japão) e a cor avaliada por um espectrofotômetro (Easyshade, Vita). Para a análise estatística dos dados, foi empregada a análise de variância multiplas, (ANOVA) e o teste de tukey ao nível de 95% de confiança. Os maiores valores de microdureza foram obtidos no baseline, seguido de 7, 14 e 90 dias. Apenas não houve diferença estatisticamente significante entre os tempos de 24 horas, 7 e 14 dias(p>0,05). Para os valores de 90 dias, ocorreu uma queda acentuada dos valores para a microdureza. Quando observados os espécimes submersos em água, nota-se alteração no armazenamento de 90 dias, mas sem diferença estatística. O líquido que promoveu o maior índice de alteração de cor foi o vinho nos grupos: R3, M3, V3 e U3. Esses dados prevaleceram em todos os cimentos testados, a partir do 7° dia de armazenamento. O /\E, não foi alterado para os grupos, que foram imersos em água. Os líquidos coca-cola, suco cítrico, whisky e energético, tiveram alteração significativa aos 90 dias de armazenamento. O grupo que apresentou a menor variação após os 14 dias foi o cimento resinoso Rely - X Veneer, porém sem diferença estatística. As substâncias nas quais os cimentos resinosos foram imersos, apresentaram influência na microdureza superficial e na cor para todos os cimentos testados, diminuindo a estabilidade de cor e a dureza em períodos mais longos.<br> / Abstracts: The aim of this in vitro study was to evaluate the microhardness and color change four resin cements immersed in six different substances and for different periods of time. Sixty discs of resin cements were cut (6mm x 2mm), for each type of cement (Rely X -Veneer (R), Rely-X U200 (U), Multilink (M) and Variolink Veneer (V)) and polished rubber tipped single step (Optrapol, Ivoclar Vivadent) for 30 s, then stored for 24 hrs in distilled water. The subdivision was carried out in six subgroups (n = 10) according to imersora solution at a temperature of 370C: R 1-group (Rely-X Veneer)-1 Group M (Multilink), GroupV-1 (Variolink Veneer) and the U-1 group (Rely-X U200) were stored in distilled water(control) (1). Group R-2, M-2, M-2 and U-2 cocaine (2). Group R-3, M-3, M-3 and H-3 'wine(3)-R 4 group, M-4, M-4 and U-4 as citric juice (4)-R 5 group, M-5, M-5 and H-5 whiskey (5)group R-6, F-6, V-6 and U-6 in the energy drink (6). The specimens were immediately mesurados, 24 hrs, 7, 14 and 90 days, by a microhardness (HMV 2, Shimadzu - Japan) and the color measured by a spectrophotometer (Easyshade, Vita). For statistical analysis, we used the multiple analysis of variance (ANOVA) and Tukey's test at 95% confidence.The highest microhardness values were obtained at baseline, followed by 7, 14 and 90 days. As there was no statistically significant difference between the times of 24 hours, 7 and 14 days (p> 0.05). For values of 90 days, there was a sharp decline in values for microhardness. When observing the specimens submerged in water, there is change in storage of 90 days, but no statistical difference. The liquid that promoted the highest rate of color change was the wine groups: R3, M3, V3 and U3. These data prevailed in all cements tested, from the 7th day of storage. The /\E, has not changed for the groups, which were immersed in water. Net cola, citrus juice, whiskey and energetic, had significantly after 90 days of storage change. The group that had the lowest variation after 14 days was the resin cement Rely X - Veneer, but without significant differences.

Page generated in 0.0288 seconds