• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 1
  • Tagged with
  • 86
  • 86
  • 76
  • 66
  • 21
  • 18
  • 18
  • 14
  • 13
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Efeito in situ do clareamento caseiro e subseqüentes tratamentos de superfície na cor e rugosidade superficial de resinas compostas / In situ effect of home bleaching and subsequent surface treatment on color and surface roughness of composite resins

Lourdes Maria González Garcia 13 April 2012 (has links)
Este estudo avaliou in situ a susceptibilidade ao manchamento de duas resinas compostas Z350 XT® (M1) e Z250® (M2), ambas da 3M/ESPE por meio da alteração de cor e rugosidade superficial após o uso do agente clareador peróxido de carbamida 16% e subseqüentes tratamentos de superfície. Foram confeccionados 156 corpos-de-prova, n=13 para cada condição experimental. O estudo crossover teve duas fases de 14 dias cada, com um período de washout de 9 dias. Os corpos de prova de cada material foram montados em placas de acetato, distribuídos em 13 voluntários, na região dos segundos pré-molares, primeiros e segundos molares superiores e instalados nos participantes para a realização do tratamento proposto em cada fase. De acordo com aleatorização, 6 voluntários utilizaram na primeira fase do experimento o gel a base de peróxido de carbamida 16% (Home Peroxide, DMC) (CCL) e 7 voluntários o gel placebo (DMC) (SCL) da mesma composição do gel original, porém sem adição do peróxido. Os voluntários aplicaram os géis nos corpos-deprova por 8h/dia, durante 14 dias nas duas fases do experimento. Após o clareamento os corpos de prova foram submetidos aos seguintes tratamentos de superfícies: polimento com discos Sof Lex (3M/ESPE) (TR1), sem tratamento de superfície (TR2) e a aplicação do selante de superfície Biscover (BISCO) (TR3) e subseqüentemente foram imersos em vinho tinto. As leituras de cor foram realizadas 24 horas após o clareamento (L0) e 24 horas após tratamento de superfície e manchamento (L1), já para a rugosidade superficial foram realizadas 3 leituras: 24 horas após a confecção dos corpos-de-prova (L0), 24 horas após o clareamento (L1) e 24 horas após tratamento de superfície e manchamento (L2). Os dados foram submetidos ao teste ANOVA e Tukey. Os resultados mostraram que: a) O Clareamento não determinou diferença estatisticamente de ΔE*, no entanto, foi significante para ΔL*, Δa* e Δb*; b) A resina M1 apresentou maior média de ΔE* que a M2; c) Os tratamentos de superfície com Sof Lex e Biscover apresentaram valores de ΔE* estaticamente semelhantes, enquanto que o sem tratamento apresentou diferença estatisticamente significante entre os materiais; d) O clareamento não teve efeito significante na rugosidade superficial de resinas estudadas; e) M1 e M2 apresentaram maior rugosidade superficial em L2 que em L0 e L1; f) TR3 apresentou maior média de rugosidade superficial que TR1 e TR2. Conclui-se que: a resina Z350 XT apresentou maior alteração de cor que a Z250; o clareamento aplicado no tempo estabelecido neste estudo não promoveu alteração de cor e não influenciou na rugosidade superficial nas resinas compostas estudadas; e as resinas compostas estudadas apresentaram maior rugosidade após o Tratamento de superfície associado ao manchamento com vinho tinto; o selante de superfície Biscover apresentou maior rugosidade superficial para a resina Z250. / This study evaluated in situ the staining susceptibility of different composite resins (Z350 XT ® (M1) and Z250 ® (M2), both of 3M/ESPE) by color change and surface roughness after the aplication of 16% carbamide peroxide bleaching gel and subsequent surface treatments and staining with red wine. One hundred fifty-six specimens were fabricated where n=13 were per experimental condition. The study had two phases of 14 days each, with a washout period of 9 days between them. The specimens of each material fixed into custom fabricated trays in 13 volunteers in the region of the second premolars, first and second molars and installed in the participants to carry out for the proposed treatment at each stage. According randomly 6 volunteers used in the first stage of the experiment the 16% peroxide carbamide gel (Home Peroxide, DMC) (CCL) and 7 volunteers used placebo gel (DMC) (SCL) that it was the same composition original gel, but without addition of peroxide. The volunteers applied the gel on the top of the specimens for 8h/day for 14 days during the two phases of the experiment. After bleaching treatment the specimens were subjected to the following surface treatments: polishing with Sof Lex (3M/ESPE) (TR1), without surface treatment (TR2) and the application of the sealant surface Biscover (BISCO) (TR3) and subsequently were immersed in red wine. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the gel, so that all used both gels. Finishing the second phase, the specimens were subjected to surface treatment and subsequent staining. The color change were measured 24 hours after bleaching in situ (L0) and 24 hours after surface treatment and red wine stains (L1) and the surface roughness were measured immediately after 24 hours of preparation of the specimens (L0) 24 hours after the in situ bleaching treatment (L1) and 24 hours after surface treatment and staining with red wine (L2). Data were submitted to ANOVA and Tukey. The results showed that: a) The bleaching showed no statistically significant difference for ΔE *, however, was significant for all parameters ΔL*, Δa* and Δb*; b) The composite 350 XT presented higher average of color change (ΔE * ) than Z250; c) The surface treatments with Sof Lex and Biscover had values of ΔE* statistically similar, while no treatment surface showed a statistically significant difference between the materials; d) Bleaching had no significant effect on surface roughness of composite resins; e) The composites showed higher values of surface roughness in L2 than in L1 and L0. f) TR3 demonstrated higher average of surface roughness than TR1 and TR2. It was concluded that bleaching did not affect the color change and surface roughness in the composites studied, the surface treatment had no effect clinically significant for the susceptibility to staining, and the composites studied had higher surface roughness when subjected to treatment surface staining associated with red wine and the surface sealant Biscover showed higher surface roughness for resin Z250.
72

POTENCIAL EROSIVO DE BEBIDAS INDUSTRIALIZADAS DE LARANJA SOBRE O ESMALTE DECÍDUO E CIMENTOS IONOMÉRICOS (IN VITRO) / Erosive potential of industrial orange beverage in deciduous enamel and glass ionomer cements (in vitro)

Gregol, Luísa Rech Gomes 28 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:23Z (GMT). No. of bitstreams: 1 Luisa Gregol.pdf: 2797827 bytes, checksum: 470916da6ea25b54a043550107a058df (MD5) Previous issue date: 2012-02-28 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The study in vitro aims to determine the erosive potential of industrialized beverages orange on deciduous enamel, glass ionomer cement with high viscosity - Ketac Molar EasyMixTM - (GIC) and glass ionomer cement modified by resin - VitremerTM - (CIVMR),by changing the hardness and surface roughness. Were prepared 60 samples of each surface divided into six groups: control, C5 and C15, orange drink with soy,S5 and S15, and orange drink, L5 and L15. For five days every group suffered erosive challenge (immersion - 6h storage - immersion - 6h storage - immersion - 12 hours of storage) and immersion time ranged from 5 to 15 minutes. The initial surface microhardness (ISM) and final (FSM) was measured using a microhardness, calibrated to make indentations with a load of 50g/5s tipped endentadora Knoop, five indentations were made by CP. The initial surface roughness (ISR) and final (FSR) was measured using a roughness of contact, five readings were made by sample.The difference in values of microhardness (FSM - ISM) between the groups was significant (p <0.05 - Student's t) for all groups IVC, the IVC-MR this difference was not significant (p> 0.05) S5 in the treatment, Deciduous Enamel and this difference was not significant (p> 0.05) in the C5 and C15. The difference in roughness values (FSR - ISR) between groups was significant (p <0.05 - Student's t) for all the CIV-MR groups, the MIC for this difference was not significant (p> 0.05) C5 group, Deciduous Enamel and this difference was not significant (p> 0.05) in the C5 and C15.Concluding that both industrialized beverages tested are orange erosive deciduous enamel and glass ionomer cements and that in times of five and fifteen minutes of soaking the change of surface microhardness and surface roughness was similar between groups. / Este estudo, in vitro, tem por objetivo determinar o potencial erosivo de bebidas industrializadas de laranja sobre o esmalte decíduo, cimento de ionômero de vidro de alta viscosidade – Ketac Molar EasyMixTM - (CIV) e cimento de ionômero de vidro modificado por resina - VitremerTM - (CIV-MR), através da alteração da microdureza e rugosidade superficial. Foram confeccionados 60 corpos de prova de cada superfície divididos em seis grupos: controle, C5 e C15, bebida de laranja com soja, S5 e S15, e bebida de laranja, L5 e L15. Durante cinco dias todos os grupos sofreram desafio erosivo (imersão – 6h de armazenamento – imersão – 6h de armazenamento – imersão – 12h de armazenamento) e o tempo de imersão variou entre 5 e 15 minutos. A microdureza superficial inicial (MSI) e final (MSF) foi verificada com microdurômetro, calibrado para realizar endentações com uma carga de 50g/5s com ponta endentadora Knoop, foram realizadas cinco endentações por CP. A rugosidade superficial inicial (RSI) e final (RSF) foi verificada utilizando-se um rugosímetro de contato, foram realizadas cinco leituras por CP. A diferença de valores de microdureza superficial (MSF-MSI) entre os grupos foi significativa (p<0,05 – t de Student) para todos os grupos CIV, o CIV-MR esta diferença não foi significativa (p>0,05) no tratamento S5, e no Esmalte Decíduo esta diferença não foi significativa (p>0,05) nos grupos C5 e C15. A diferença dos valores de rugosidade (RSF – RSI) entre os grupos foi significativa (p<0,05 – t de Student) para todos os grupos CIV-MR, para o CIV esta diferença não foi significativa (p>0,05) no grupo C5,e no Esmalte Decíduo esta diferença não foi significativa (p>0,05) nos grupos C5 e C15. Concluindo-se que as duas bebidas industrializadas de laranja testadas são erosivas ao esmalte decíduo e aos cimentos de ionômero vidro e que nos tempos de cinco e quinze minutos de imersão a alteração de microdureza superficial e de rugosidade superficial foi semelhante entre os grupos.
73

"Avaliação de cerâmicas odontológicas quanto à resistência de união com a dentina, por ensaio de tração, microdurezas Knoop e Vickers, rugosidade superficial e microscopia de força atômica" / Evaluation of dental ceramics regarding tensile bond strength to dentin, Knoop and Vickers’ microhardness, surface roughness and atomic force microscopy

Martuci, Ricardo Ruiz 01 June 2006 (has links)
Foram ensaiadas quatro cerâmicas VMK 95, Omega 900, IPS d. Sign e Cergogold. Os ensaios realizados foram: 1) resistência de união, por ensaio de tração, à dentina humana, de cones (6 x 3 x 5mm) de cerâmica, unidos por meio de cimentos fosfato de zinco, resinosos Rely X e Panávia F (n=10); 2) rugosidade pelos parâmetros Ra, Rt, Ry, Rz e Rp, de superfícies tratadas com ácido fluorídrico a 10% e polidas (n=10); 3) durezas Knoop e Vickers (n=4); 4) análise por microscopia de força atômica de superfícies polidas apenas (n=5). Os dados foram analisados pela análise de variância e testes de Tukey foram feitos quando necessário. A resistência de união com o fosfato de zinco e o parâmetro de rugosidade Ra foram analisados em separado, por apresentarem variâncias bem menores que as correspondentes aos demais agentes cimentantes e parâmetros. Os resultados mostraram que a resistência de união com o fosfato de zinco foi muito baixa (1,61 a 2,91MPa), nas condições dos ensaios. Com cimentos resinosos a resistência média variou de 16,61 a 18,47MPa. O cimento Rely X apresentou menor resistência em média, mas isto também depende da cerâmica.As rugosidades das superfícies tratadas com ácido fluorídrico a 10% foram bem maiores do que nas polidas. Nessas o parâmetro Ra variou de 2,15 a 4,26µm e os demais parâmetros de 10,99 a 21,93µm. Nas superfícies polidas o Ra variou de 0,53 a 0,84µm. Os demais parâmetros apresentaram médias de 2,01 a 5,23µm. A dureza Knoop variou de 418,9 a 493,8 kgf/mm2 e a Vickers de 492,5 a 572,2 kgf/mm2. Esta última apresentou valores maiores. A microscopia de força atômica permitiu visualizar irregularidades de superfícies. As principais conclusões foram: o cimento de fosfato de zinco, na condição do ensaio (por tração) apresentou resistência de união muito baixa; com os cimentos resinosos a resistência de união foi bem alta; as rugosidades foram muito altas após o tratamento superficial com ácido fluorídrico a 10%, mas, as polidas apresentaram valores bem baixos; as durezas Vickers fornecem valores maiores que a Knoop. / Four ceramics (VMK 95, Omega 900, IPS d.Sign and Cergogold) were tested regarding: 1) tensile bond strength to human dentin of ceramic cones (6 x 3 x 5mm), cemented with zinc phosphate, and resin cements, Rely X and Panávia F (n=10); 2) roughness by means of parameters Ra, Rt, Ry, Rz and Rp, of HF (10%) surface treated and polished surfaces (n=10); 3) Knoop and Vickers hardness (n=4); 4) atomic force microscopy; only of polished surfaces (n=5). Data were analyzed by ANOVA and when necessary were used Tukey’s tests. Tensile bond strength with zinc phosphate cement and Ra roughness parameter were analyzed separately because of their low variances when compared with those of resin cements and the other roughness parameter. Results showed that tensile bond strength of zinc phosphate was very low (1.61 to 2.91MPa) in this test condition (tensile test). Resin cements presented tensile bond strength at range 16.61 to 18.47MPa. Cement Rely X presented lower strength, but it depends also of ceramic. HF (10%) treated surfaces presented much higher roughness than polished ones. In HF (10%) treated surfaces parameter Ra ranged from 2.15 to 4.26µm and the other parameter ranged from 10.99 to 21.93µm. Roughness of polished surfaces Ra ranged from 0.53 to 0.84µm. Range of the other parameter was from 2.01 to 5.23µm. Knoop hardness ranged from 418.9 to 493.8 kgf/mm2 and Vicker’s from 492.5 to 572.2 kgf/mm2. This type presented higher values. Atomic force microscopy permited good vision of surface irregularities. Main conclusions were: zinc phosphate cement at test conditions (tensile) presented low bond strength; resin cements presented high tensile bond strength; surface treatment with HF (10%) led to high roughness but in polished one it was low; Vicker’s hardness presented higher values than Knoop one.
74

Influência de diferentes métodos de condicionamento superficial em pinos pré-fabricados resinosos fibro-reforçados em vidro e quartzo na resistência adesiva a compósito de polimerização dual: teste de push-out / Influence of different pretreatments in glass and quartz fiber posts on the bond strength of a dual-cure resin core material: push-out test

Leandro Passos Soares 07 February 2012 (has links)
O objetivo deste estudo foi realizar uma avaliação tridimensional da rugosidade superficial em 3 tipos de pinos de fibra - DT LightPost, FRC Postec Plus e Transluma Post - submetidos a diferentes tratamentos de superfície e avaliar os efeitos dos pré-tratamentos na resistência adesiva a um compósito de presa dual Biscore. Os tratamentos de superfície foram: imersão em ácido hidrofluorídrico, jateamento com óxido de alumínio a 50m, imersão em peróxido de hidrogênio, jateamento com óxido de alumínio a 50m seguido de imersão em ácido hidrofluorídrico e jateamento com óxido de alumínio a 50m seguido de imersão em peróxido de hidrogênio. No experimento 1, 75 pinos foram divididos em 3 grupos (n = 25), de acordo com seu fabricante e subdivididos em cinco subgrupos. A rugosidade superficial foi medida usando um rugosímetro tridimensional e analisada com o software de análise 3D. Os valores de rugosidade foram obtidos antes e após diferentes tratamentos de superfície na área dos mesmos corpos-de-prova. Para o experimento 2, foram utilizados os mesmos corpos-de-prova, os mesmos grupos e subgrupos do experimento 1, tendo sido adicionado o subgrupo de controle (n=90) e a resistência adesiva a um compósito presa dual Biscore foi mensurada através de um teste push-out. A resistência adesiva foi medida em uma máquina universal de ensaios, com uma célula de carga tipo SLBL-5kN em uma velocidade de 0,5 mm / min. Os resultados do experimento 1 foram analisados através de um teste estatístico t-Student. Jateamento e jateamento seguido de imersão em ácido hidrofluorídrico produziram um aumento estatisticamente significante na rugosidade, contudo somente o tratamento por jateamento proporcionou um aumento significativo nos valores de rugosidade. Os resultados do experimento 2 foram obtidos através de um um teste t-unilateral de hipótese com variância desconhecida. Concluiu-se que o jateamento com óxido de alumínio a 50&#956;m em uma distância de 30 mm a 2,5 bar de pressão por 5 segundos foi suficiente para modificar a topografia dos pinos de fibra de vidro e quartzo e que o jateamento com partículas de 50 &#956; alumina a distância de 30 mm a 2,5 bar de pressão por 5 segundos foi o único tratamento de superfície que aumentou a resistência adesiva do compósito Biscore aos pinos DT Light Post e Transluma Post. Os pinos FRC Postec Plus não demostraram um aumento estatisticamente significante na resistência adesiva em nenhum grupo. / The aim of this study was to perform a tridimensional surface roughness test evaluation of different surface treatments to 3 types of fiber posts - DT LightPost, FRC Postec Plus e Transluma Post - and evaluate the effects of the different pretreatments on the bond strength of a dual-cure resin core material Biscore. The different surface treatments were: immersion in hydrofluoric acid, sandblasting abrasion with 50 alumina particles, immersion in hydrogen peroxide, sandblasting abrasion with 50 alumina particles followed by immersion in hydrofluoric acid and sandblasting abrasion with 50 alumina particles followed by immersion in hydrogen peroxide. In the first experiment seventy five fiber posts were divided into 3 groups (n = 25), according to their manufacturer and subdivided into 5 subgroups. Surface roughness was measured using a tridimensional surface roughness test and analyzed with 3D analysis software. Surface roughness was obtained before and after the different surface treatments at the same post area. In the second experiment the same samples divided in groups and subgroups were used, but a control group (no treatment) was added (n = 90) and the bond strength to a composite resin core material Biscore was measured using a push-out design. The interfacial push-out bond strength was measured in a universal testing machine, with a load cell type SLBL-5kN at a crosshead speed of 0.5 mm/min. Results in experiment 1 were statistically analyzed using Students t-Test. Sandblasting and sandblasting followed by immersion in hydrofluoric acid produced a significant increase in roughness, but the sandblasting treatment was able to provide a significant roughness increase. Results in experiment 2 were statistically analysed using one-sided t-Test of Hypothesis with unknown variance. It was concluded that sandblasting airborne-particle abrasion with alumina 50 at a distance of 30 mm at 2.5 bars pressure for 5 seconds was sufficient to modify the surface topography of glass and quartz fiber posts and the sandblasting abrasion with 50 alumina particles at a distance of 30 mm at 2.5 bars pressure for 5 seconds was the only surface treatment in DT Light Post and Transluma Post that increased the bond strength to dual cure resin composite cores. FRC Postec Plus post did not shown an increase in bond strength in any group.
75

Influência de diferentes métodos de condicionamento superficial em pinos pré-fabricados resinosos fibro-reforçados em vidro e quartzo na resistência adesiva a compósito de polimerização dual: teste de push-out / Influence of different pretreatments in glass and quartz fiber posts on the bond strength of a dual-cure resin core material: push-out test

Leandro Passos Soares 07 February 2012 (has links)
O objetivo deste estudo foi realizar uma avaliação tridimensional da rugosidade superficial em 3 tipos de pinos de fibra - DT LightPost, FRC Postec Plus e Transluma Post - submetidos a diferentes tratamentos de superfície e avaliar os efeitos dos pré-tratamentos na resistência adesiva a um compósito de presa dual Biscore. Os tratamentos de superfície foram: imersão em ácido hidrofluorídrico, jateamento com óxido de alumínio a 50m, imersão em peróxido de hidrogênio, jateamento com óxido de alumínio a 50m seguido de imersão em ácido hidrofluorídrico e jateamento com óxido de alumínio a 50m seguido de imersão em peróxido de hidrogênio. No experimento 1, 75 pinos foram divididos em 3 grupos (n = 25), de acordo com seu fabricante e subdivididos em cinco subgrupos. A rugosidade superficial foi medida usando um rugosímetro tridimensional e analisada com o software de análise 3D. Os valores de rugosidade foram obtidos antes e após diferentes tratamentos de superfície na área dos mesmos corpos-de-prova. Para o experimento 2, foram utilizados os mesmos corpos-de-prova, os mesmos grupos e subgrupos do experimento 1, tendo sido adicionado o subgrupo de controle (n=90) e a resistência adesiva a um compósito presa dual Biscore foi mensurada através de um teste push-out. A resistência adesiva foi medida em uma máquina universal de ensaios, com uma célula de carga tipo SLBL-5kN em uma velocidade de 0,5 mm / min. Os resultados do experimento 1 foram analisados através de um teste estatístico t-Student. Jateamento e jateamento seguido de imersão em ácido hidrofluorídrico produziram um aumento estatisticamente significante na rugosidade, contudo somente o tratamento por jateamento proporcionou um aumento significativo nos valores de rugosidade. Os resultados do experimento 2 foram obtidos através de um um teste t-unilateral de hipótese com variância desconhecida. Concluiu-se que o jateamento com óxido de alumínio a 50&#956;m em uma distância de 30 mm a 2,5 bar de pressão por 5 segundos foi suficiente para modificar a topografia dos pinos de fibra de vidro e quartzo e que o jateamento com partículas de 50 &#956; alumina a distância de 30 mm a 2,5 bar de pressão por 5 segundos foi o único tratamento de superfície que aumentou a resistência adesiva do compósito Biscore aos pinos DT Light Post e Transluma Post. Os pinos FRC Postec Plus não demostraram um aumento estatisticamente significante na resistência adesiva em nenhum grupo. / The aim of this study was to perform a tridimensional surface roughness test evaluation of different surface treatments to 3 types of fiber posts - DT LightPost, FRC Postec Plus e Transluma Post - and evaluate the effects of the different pretreatments on the bond strength of a dual-cure resin core material Biscore. The different surface treatments were: immersion in hydrofluoric acid, sandblasting abrasion with 50 alumina particles, immersion in hydrogen peroxide, sandblasting abrasion with 50 alumina particles followed by immersion in hydrofluoric acid and sandblasting abrasion with 50 alumina particles followed by immersion in hydrogen peroxide. In the first experiment seventy five fiber posts were divided into 3 groups (n = 25), according to their manufacturer and subdivided into 5 subgroups. Surface roughness was measured using a tridimensional surface roughness test and analyzed with 3D analysis software. Surface roughness was obtained before and after the different surface treatments at the same post area. In the second experiment the same samples divided in groups and subgroups were used, but a control group (no treatment) was added (n = 90) and the bond strength to a composite resin core material Biscore was measured using a push-out design. The interfacial push-out bond strength was measured in a universal testing machine, with a load cell type SLBL-5kN at a crosshead speed of 0.5 mm/min. Results in experiment 1 were statistically analyzed using Students t-Test. Sandblasting and sandblasting followed by immersion in hydrofluoric acid produced a significant increase in roughness, but the sandblasting treatment was able to provide a significant roughness increase. Results in experiment 2 were statistically analysed using one-sided t-Test of Hypothesis with unknown variance. It was concluded that sandblasting airborne-particle abrasion with alumina 50 at a distance of 30 mm at 2.5 bars pressure for 5 seconds was sufficient to modify the surface topography of glass and quartz fiber posts and the sandblasting abrasion with 50 alumina particles at a distance of 30 mm at 2.5 bars pressure for 5 seconds was the only surface treatment in DT Light Post and Transluma Post that increased the bond strength to dual cure resin composite cores. FRC Postec Plus post did not shown an increase in bond strength in any group.
76

Dinâmica de crescimento de filmes de platina e ouro / Growth dynamics of films of platinum and gold.

Leonidas Lopes de Melo 28 May 2004 (has links)
O caráter aleatório e não homogêneo do crescimento de filmes finos, por processo de deposição, leva à formação de uma superfície rugosa que obedece, em geral, a uma geometria fractal. A dinâmica de crescimento da superfície do filme pode ser descrita por meio de modelos de crescimento discretos, simulações numéricas e equações diferenciais estocásticas. Os modelos e as equações nos fornecem os expoentes críticos, que descrevem o comportamento da rugosidade com a escala de observação e tempo de deposição. Crescemos filmes de platina e ouro através da técnica de implantação e deposição de íons por imersão em plasma metálico. Determinamos experimentalmente os expoentes críticos por meio de microscopia de tunelamento. Comparamos os nossos resultados experimentais com previsões dadas por alguns modelos teóricos. Verificamos que há um bom acordo entre eles e as previsões dadas pela equação estocástica de Kardar, Parisi e Zhang. A estrutura cristalina dos materiais também foi analisada por meio de difração de raios x. / The randomness and inhomogeneities in the growth of thin films generate a rough surface obeying, in general, fractal geometry. The growth dynamics of film surface can be described by theoretical discrete models, numerical simulations and stochastic differential equations. Models and equations give the critical exponents that describe the behavior of roughness with the observation scale and deposition time. We have synthesized platinum and gold films by metal plasma immersion ion implantation and deposition. We have measured the critical exponents by Scanning Tunneling Microscopy. Our experimental results were compared with some theoretical models predictions. We verified that there is a good agreement between them and the theoretical predictions given by the Kardar, Parisi and Zhang stochastic equation. The crystallographic structure was also analyzed by X-ray diffraction.
77

Influência do tipo de polimento pós-clareamento na alteração de rugosidade, cor e brilho da superfície de esmalte dental humano / Different polishing procedures influence in roughness, color and gloss of bleached human dental enamel surface

Ana Carolina Pedreira de Freitas 05 November 2010 (has links)
O tratamento clareador pode resultar em alterações na rugosidade superficial do esmalte dental, as quais podem ser vistas a olho nu como alterações de cor, opacidade e perda de brilho. O objetivo deste estudo foi analisar in vitro a alteração de rugosidade, cor e brilho de superfícies de esmalte dental humano após clareamento com um produto a base de peróxido de hidrogênio (PH) 38% e após polimento com fluoreto de sódio 2% neutro (FS2%) ou pasta dentifrícia contendo partículas de nano-hidroxiapatita. Para isso, coroas de incisivos centrais humanos foram preparadas e tiveram suas faces vestibulares analisadas em microscópio de força atômica (MFA), o qual determinou os valores de rugosidade [Ra, RMS, Z range e Power Spectral Density (PSD)] iniciais. A cor e o brilho destas amostras foram determinados por um espectrofotômetro. Todas as amostras foram clareadas com PH 38% por 135 minutos. Os valores de Ra, RMS, Z range e PSD foram estabelecidos pelo MFA e a cor e o brilho determinados pelo espectrofotômetro. As amostras foram divididas em dois grupos: Flúor, que recebeu um polimento com gel de FS2%; e nHA, que recebeu um polimento com pasta dentifrícia contendo partículas de nano-hidroxiapatita. Os valores de Ra, RMS, Z range, PSD, cor e brilho pós-polimento foram determinados pelo MFA e espectrofotômetro. Após o clareamento, os valores de Ra, RMS, Z range e PSD não apresentaram alteração estatisticamente significante, os valores de L* aumentaram e C* diminuiu significativamente em todas as amostras. O brilho superficial não apresentou alteração significativa após o clareamento. O grupo Flúor não apresentou alteração de rugosidade significativa para Ra, RMS, Z range e PSD após o polimento. Os valores de L*, C* e brilho superficial também não apresentaram alterações significativas após o polimento das superfícies clareadas. No grupo nHA, os valores de Ra e RMS não apresentaram alteração significativa após o polimento das superfícies clareadas, porém os valores de Z range e PSD apresentaram alteração estatisticamente significante. Em comparação à superfície clareada, L* e C* não apresentaram alteração significante após o polimento, porém o brilho superficial foi significativamente maior. O tratamento clareador de consultório mostrou ser eficiente quanto à alteração de cor e não gerou aumento na rugosidade superficial do esmalte dental. Um polimento com pasta dentifrícia contendo partículas de nano-hidroxiapatita realizado após o clareamento é capaz de aumentar o brilho e diminuir a rugosidade superficial do esmalte dental. / Bleaching treatment may result in dental enamel surface roughness alterations, which might be seen as color alterations, opacity and gloss loss. The aim of this research was to in vitro investigate roughness, color and gloss alterations of human dental enamel surfaces after bleaching treatment with 38% hydrogen peroxide (HP) and after polishing with neutral 2% sodium fluoride or dental tooth paste containing nano-hydroxiapatite particles. Human central incisors were prepared and buccal surfaces were analyzed by an atomic force microscope (AFM), which determined roughness values [Ra, RMS, Z range and Power Spectral Density (PSD)]. Surface color and gloss were determined by a spectrophotometer. All samples were bleached with 38% HP for 135 minutes. AFM determined Ra, RMS, Z range and PSD after bleaching. Color and gloss were determined by the spectrophotometer. Samples were distributed in two different groups: Fluor, which was polished with neutral 2% sodium fluoride, and nHA, which was polished with dental tooth paste containing nano-hydroxyapatite particles. Ra, RMS, Z range, PSD, color and gloss values were determined by AFM and spectrophotometer after polishing. After bleaching, Ra, RMS, Z range and PSD didnt show any statistical difference. L* increased and C* decreased significantly in all samples after bleaching. Surface gloss didnt show significant alteration after bleaching. Fluor group didnt show surface roughness alteration considering Ra, RMS, Z range and PSD after polishing. L*, C* and gloss didnt change after bleached surfaces are polished with neutral 2% sodium fluoride. Ra and RMS of nHA group didnt change significantly after polishing, but Z range and PSD showed significant alteration. Despite L* and C* didnt change, gloss increased significantly after polishing with dental tooth paste containing nano-hydroxyapatite. In-office bleaching treatment showed to be efficient as for color enhancement and didnt cause roughness alteration in dental enamel surface. An after-bleaching polishing with dental tooth paste containing nano-hydroxyapatite particles may increase gloss and decrease surface roughness of dental enamel.
78

"Avaliação de cerâmicas odontológicas quanto à resistência de união com a dentina, por ensaio de tração, microdurezas Knoop e Vickers, rugosidade superficial e microscopia de força atômica" / Evaluation of dental ceramics regarding tensile bond strength to dentin, Knoop and Vickers’ microhardness, surface roughness and atomic force microscopy

Ricardo Ruiz Martuci 01 June 2006 (has links)
Foram ensaiadas quatro cerâmicas VMK 95, Omega 900, IPS d. Sign e Cergogold. Os ensaios realizados foram: 1) resistência de união, por ensaio de tração, à dentina humana, de cones (6 x 3 x 5mm) de cerâmica, unidos por meio de cimentos fosfato de zinco, resinosos Rely X e Panávia F (n=10); 2) rugosidade pelos parâmetros Ra, Rt, Ry, Rz e Rp, de superfícies tratadas com ácido fluorídrico a 10% e polidas (n=10); 3) durezas Knoop e Vickers (n=4); 4) análise por microscopia de força atômica de superfícies polidas apenas (n=5). Os dados foram analisados pela análise de variância e testes de Tukey foram feitos quando necessário. A resistência de união com o fosfato de zinco e o parâmetro de rugosidade Ra foram analisados em separado, por apresentarem variâncias bem menores que as correspondentes aos demais agentes cimentantes e parâmetros. Os resultados mostraram que a resistência de união com o fosfato de zinco foi muito baixa (1,61 a 2,91MPa), nas condições dos ensaios. Com cimentos resinosos a resistência média variou de 16,61 a 18,47MPa. O cimento Rely X apresentou menor resistência em média, mas isto também depende da cerâmica.As rugosidades das superfícies tratadas com ácido fluorídrico a 10% foram bem maiores do que nas polidas. Nessas o parâmetro Ra variou de 2,15 a 4,26µm e os demais parâmetros de 10,99 a 21,93µm. Nas superfícies polidas o Ra variou de 0,53 a 0,84µm. Os demais parâmetros apresentaram médias de 2,01 a 5,23µm. A dureza Knoop variou de 418,9 a 493,8 kgf/mm2 e a Vickers de 492,5 a 572,2 kgf/mm2. Esta última apresentou valores maiores. A microscopia de força atômica permitiu visualizar irregularidades de superfícies. As principais conclusões foram: o cimento de fosfato de zinco, na condição do ensaio (por tração) apresentou resistência de união muito baixa; com os cimentos resinosos a resistência de união foi bem alta; as rugosidades foram muito altas após o tratamento superficial com ácido fluorídrico a 10%, mas, as polidas apresentaram valores bem baixos; as durezas Vickers fornecem valores maiores que a Knoop. / Four ceramics (VMK 95, Omega 900, IPS d.Sign and Cergogold) were tested regarding: 1) tensile bond strength to human dentin of ceramic cones (6 x 3 x 5mm), cemented with zinc phosphate, and resin cements, Rely X and Panávia F (n=10); 2) roughness by means of parameters Ra, Rt, Ry, Rz and Rp, of HF (10%) surface treated and polished surfaces (n=10); 3) Knoop and Vickers hardness (n=4); 4) atomic force microscopy; only of polished surfaces (n=5). Data were analyzed by ANOVA and when necessary were used Tukey’s tests. Tensile bond strength with zinc phosphate cement and Ra roughness parameter were analyzed separately because of their low variances when compared with those of resin cements and the other roughness parameter. Results showed that tensile bond strength of zinc phosphate was very low (1.61 to 2.91MPa) in this test condition (tensile test). Resin cements presented tensile bond strength at range 16.61 to 18.47MPa. Cement Rely X presented lower strength, but it depends also of ceramic. HF (10%) treated surfaces presented much higher roughness than polished ones. In HF (10%) treated surfaces parameter Ra ranged from 2.15 to 4.26µm and the other parameter ranged from 10.99 to 21.93µm. Roughness of polished surfaces Ra ranged from 0.53 to 0.84µm. Range of the other parameter was from 2.01 to 5.23µm. Knoop hardness ranged from 418.9 to 493.8 kgf/mm2 and Vicker’s from 492.5 to 572.2 kgf/mm2. This type presented higher values. Atomic force microscopy permited good vision of surface irregularities. Main conclusions were: zinc phosphate cement at test conditions (tensile) presented low bond strength; resin cements presented high tensile bond strength; surface treatment with HF (10%) led to high roughness but in polished one it was low; Vicker’s hardness presented higher values than Knoop one.
79

Efeito in situ da associação de chá preto ao uso diário de clorexidina na alteração de cor e rugosidade superficial de resinas compostas / Influence of in situ association of black tea and chlorhexidine on the color change and surface roughness of composite resins.

Ana Paula Terossi de Godoi 11 December 2009 (has links)
O presente estudo avaliou in situ a influência de fatores da dieta associado ao uso de clorexidina na cor e na rugosidade superficial de diferentes resinas compostas (Z250® - 3M-ESPE e Filtek Supreme® - 3M-ESPE). Foram confeccionados 112 corpos-de-prova (6,0x2,0mm) que foram polidos com disco abrasivos Super Snap® (Shofu). O estudo foi constituído por duas fases de 5 dias cada, com um período de washout de 9 dias entre elas. Os corpos-de-prova de cada um dos materiais foram divididos entre 14 voluntários e montados em dispositivo palatino, na região dos pré-molares e molares superiores e instalados nos participantes para a realização dos bochechos e da ingestão do chá em cada uma das fases do experimento. De acordo com sorteio aleatório, metade dos voluntários utilizou, na primeira fase do experimento, solução de gluconato de clorexidina 0,12% (S1) e a outra metade dos voluntários realizou os bochechos com uma solução placebo (S2), de mesma composição da solução original, porém sem adição de gluconato de clorexidina 0,12%. Os bochechos foram realizados 2 vezes ao dia, por 1 minuto, durante 5 dias. Todos os voluntários, após o bochecho com gluconato de clorexidina 0,12% ou placebo ingeriram 200 mL de chá em ambas as fases. Na segunda fase do experimento, os corpos-de-prova foram substituídos por outros e os voluntários foram cruzados quanto à solução, de modo que todos usaram ambas às soluções. As leituras de cor, obtidas através de um colorímetro, e a rugosidade superficial, obtida por meio de um rugosímetro, foram realizadas imediatamente antes da fixação do espécime no aparelho intra-bucal e após 24 horas do término do período experimental. Os dados foram submetidos ao teste ANOVA e Tukey (p&le;0,05). Os resultados mostraram que: a) a solução S1obteve maiores médias de alteração de cor (&Delta;E*) que S2 enquanto que para os outros fatores e interações não houve diferença estatisticamente significante para esta variável; b) todos os fatores e respectivas interações, exceto a interação Solução x Material, sofreram variação de luminosidade (L*) significante estatisticamente; c) todos os fatores e respectivas interações, exceto a interação Material x Tempo, sofreram variação do parâmetro a* significantes estatisticamente; d) o fator Solução quando analisado isoladamente e a interação Tempo x Solução não obtiveram resultados estatisticamente diferentes para o parâmetro b* e; e) para a rugosidade superficial (Ra) apenas o fator Tempo foi estatisticamente significante. Conclui-se que: houve uma maior alteração de cor da resina composta quando se utiliza soluções a base de Clorexidina 0,12%; as resinas estudadas não influenciaram no comportamento da cor quando associado à Clorexidina 0,12% e chá preto; para os parâmetros L* a* e b* os fatores Solução, Material e Tempo tiveram efeito significante, exceto o fator Solução para o parâmetro b*; a utilização de Clorexidina durante 5 dias não influenciou na rugosidade superficial dos materiais estudados e; o tempo teve influencia sobre o aumento da rugosidade superficial. / This in situ study evaluated the influence of dietary factors in association with chlorhexidine on the color change (&Delta;E*) of two composites resins (Z250® - 3M-ESPE and Filtek Supreme® - 3M-ESPE). 112 discs (6.0x2.0mm) were fabricated and polished with Super Snap® discs (Shofu). The specimens were divided among 14 volunteers, and fitted onto intraoral devices and placed in the maxillary premolar and molar positions. Palatal intra-oral acrylic resin appliances were made for each volunteers in the experiment. In each appliance, two specimen of each materials was randomly fixed. This study was composed of two phases of 5 days each, with a washout period of 9 days between them. In the first phase, half of the volunteers chosen by random draw, used a 0.12% chlorhexidine solution (S1) and the other half used a placebo solution (S2). The mouthwashes were performed 2 times a day, for 1 min. each, for 5 days. In the second phase of the experiment, the specimens were replaced by others and the volunteers were crossed on the outcome. In both phases, after mouthwashes with S1 or S2, all volunteers ingested 200 mL of black tea for 10 minutes. The color change of all specimens before and after of the experimental period was measured by a colorimeter and the data were analyzed by two-way analysis of variance (ANOVA) and Tukey´s test (&alpha=.05). Subsequently, the surface roughness (Ra) of the specimens was evaluated using a profilometer, and the data were compared by two-way ANOVA followed by a Tukey multiple comparations test (&alpha;=.05). According to ANOVA: a) the S1 solution had the highest means of color change (&Delta;E*) that S2, while for the others factors and interactions no have statistically significant difference for this variable; b) all the factors and their interactions had significant statistically changes in lightness (L*), except for the Solution x Material interaction; c) all the factores and their interactions had significant statistically changes in parameter a*, except for the Material x Time interaction; d) the solution factor and Time x Solution interaction no had statistica different for the parameter b* and; e) for surface roughness (Ra) only the time factor was statistically significant. It was concluded that: there was an increase in color change of composite resin when using Chlorhexidine 0.12%; the resin did not influence on the color when associated with Chlorhexidine 0.12% and black tea; for parameters L * a * b * Solution, Material and Time factors had significant effect, except for the Solution factor for the parameter b *; the use of chlorhexidine for 5 days did not influence the surface roughness of the materials studied; and the time had a significant influence on increased surface roughness.
80

Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem / Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage

VENTURINI, Daniela 30 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:17Z (GMT). No. of bitstreams: 1 Dissertacao_Daniela_Venturini.pdf: 913438 bytes, checksum: e17fa4ddbe1c025e3411319cac841d1e (MD5) Previous issue date: 2006-06-30 / This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups / Este estudo avaliou os efeitos do polimento imediato e mediato na rugosidade média superficial (Ra), dureza Knoop (KHN) e microinfiltração de um compósito microparticulado (Filtek A110) e um híbrido (Filtek Z250), após um ano de armazenagem dos espécimes. Preparos padronizados de 3mm mesio-distais, 3mm inciso-cervicais e 2mm de profundidade foram realizados na face vestibular de 256 incisivos bovinos, metade destes foi restaurada com cada tipo de compósito. Imediatamente após a fotoativação realizado o acabamento com lixa d água de granulação 280. Os espécimes restaurados com cada compósito foram divididos em dois grupos. O primeiro grupo (IM) foi polido imediatamente após o acabamento, usando três sistemas diferentes (n=16): A- Sof-Lex (3M-ESPE), B- FlexiCups (Cosmedent), C- (técnica seqüencial)- a seqüência de FlexiCups, Jiffy Polishing Brush (Ultradent) e FlexiBuffs (Cosmedent). Os espécimes foram então armazenados em solução salina a 37ºC. O segundo grupo (ME) foi armazenado por duas semanas e então polido com os mesmos sistemas. Parte dos espécimes foi analisada numa primeira etapa do experimento e o restante ficou armazenado por um ano em água destilada a 37ºC. Cinco leituras por espécimes foram realizadas para Ra e KHN. Após imersão em fucsina básica realizou-se o teste de penetração de corante sendo após analisado sob aumento (40x) usando escores padrão. Os dados foram verificados através de Análise de Variância e teste SNK (Ra e KHN). Também foram utilizados os testes de Mann-Whitney ou Kruskal-Wallis (microinfiltração). Para comparação com os dados baseline foram utilizados os testes t de Student (Ra) e Mann-Withney (infiltração marginal). Todos os testes foram executados com significância de 5%. Após um ano de armazenagem os espécimes do compósito A110 apresentaram significativamente menor rugosidade e menor dureza. A técnica seqüencial promoveu a menor rugosidade e os discos Sof-Lex a menor dureza, essas diferenças foram estatisticamente significantes. Os escores de infiltração marginal foram semelhantes entre os grupos. Após um ano de armazenagem os espécimes apresentaram um aumento significativo na rugosidade. O polimento IM mostrou-se igual, ou melhor, que o ME tanto para a infiltração marginal como para a rugosidade superficial para a maioria dos grupos analisados, no entanto tal fato não foi observado quanto à dureza superficial, exceto quando foi utilizada a técnica seqüencial

Page generated in 0.393 seconds