• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 21
  • 21
  • 21
  • 12
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comparação entre imagens digitais diretas e laser de diodo na detecção de cáries proximais e oclusais /

Araujo, Elaine Aparecida Félix de. January 2004 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Solange Maria de Almeida / Banca: Claudio Costa / Banca: Mari Elí Leonelli de Moraes / Banca: Ana Paula Martins Gomes / Resumo: O objetivo neste trabalho foi avaliar a acurácia na detecção de cáries proximais e oclusais comparando a imagem digital com o laser de diodo. Foram avaliados 33 pré-molares e 33 molares humanos extraídos e submetidos à idêntica padronização geométrica. Usando uma escala de confiança com cinco escores, quatro observadores determinaram a ausência ou presença de cárie por três sistemas auxiliares de diagnóstico: a) exame da imagem do Visualix; b) exame da imagem do RVG; c) exame utilizando o DIAGNOdent. O padrão ouro foi determinado pela análise histológica das secções. Com os valores obtidos foi gerada uma curva ROC e realizado o teste Kappa que determinou a concordância intra e ínterobservadores. Os resultados indicaram que as imagens digitais foram melhores na detecção de cáries proxímais que o laser DIAGNOdent e semelhantes na detecção de cáries oclusais / Abstract : The purpose of this study was to evaluate the accuracy of approximal and occlusal caries detection comparing Visualix and RVG CCD-based digital image with laser DIAGNOdent Sixty-six extracted posterior teeth were imaged under identical standardized geometric and exposure conditions. Four examiners, using five point confidence scale, rated 132 proximal and 66 occlusal surfaces for the presence or absence of carious lesions by means of three diagnostic systems: a) Visualix; b) RVG; c) DIAGNOdent. The gold standard was determined by microscopy analysis of sections. Receiver Operating Characteristic curves were generated analyzed with Kappa the according intra and interexaminers. The results indicated that digital images were better to detection approximal caries than laser Diagnodent and similar to occlusal caries / Doutor
12

Avaliação automatica de parametros fisicos de qualidade de imagem em sistemas de radiologia digital odontologica

Albuquerque, Jorge Andre Girão 29 July 2018 (has links)
Orientador : Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:59:46Z (GMT). No. of bitstreams: 1 Albuquerque_JorgeAndreGirao_M.pdf: 5796408 bytes, checksum: 09bd57e0a31a84f22f0e6c4d5ab05252 (MD5) Previous issue date: 2001 / Mestrado
13

Sistema de avaliação de qualidade de imagem em radiologia digital odontologica / Image quality evaluation system for dental digital radiology

Leão, Tiago Freire Carneiro 13 August 2018 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T16:14:16Z (GMT). No. of bitstreams: 1 Leao_TiagoFreireCarneiro_M.pdf: 2505362 bytes, checksum: 6d6b07198f62fd7206b28e629cc5ba41 (MD5) Previous issue date: 2009 / Resumo: Novas tecnologias e sistemas de detecção de radiação para a geração de imagens radiográficas odontológicas vêm sendo disponibilizados como alternativa aos filmes radiográficos. Sistemas baseados em tecnologia do tipo PSPL parecem superar algumas das restrições encontradas nos sistemas baseados em tecnologia CCD, tais como volume do detector, cabos de conexão, tamanho limitado da imagem e limitação da latitude. É importante que seja possível comparar sistemas de imagem concorrentes (diferentes tecnologias ou diferentes fabricantes com mesma tecnologia), utilizando ferramentas e protocolos de controle e certificação de qualidade. Foi desenvolvido um pacote computacional e um conjunto de simuladores e foi realizada a análise de dois sistemas comerciais baseados na tecnologia PSPL, de forma a validar o sistema desenvolvido. O programa desenvolvido permite obter e analisar: curva sensitométrica, função de transferência de modulação (MTF), densidade espectral de potência (NPS), quanta equivalente de ruído (NEQ) e eficiência na detecção de quanta (DQE). Os resultados mostraram que o pacote computacional e o conjunto de simuladores permitem realizar o controle de qualidade de sistemas de radiografia digital odontológica de maneira quantitativa e objetiva, facilitando a análise comparativa entre diferentes sistemas comerciais. Palavras-chave: Radiologia digital odontológica, controle de qualidade em radiodiagnóstico, curva sensitométrica, detecção equivalente de quanta, função de transferência de modulação, densidade espectral de ruído, quanta equivalente de ruído. / Abstract: New systems and technologies for radiation detection intended for dental radiology have become available as an alternative to dental radiographic film. Systems based on PSPL technology seems to overcome some of the restrictions of systems based on CCD technology such as the bulky detector, connecting wire, limited image size and limited exposure latitude. It is important that competing imaging systems can be compared (different technologies or different manufacturers of the same technology) by means of quality control tools and quality certification protocols. A software package and a set of specific phantoms were developed and the analyses of two competing PSPL systems were conducted to validate the developed system. The software allows the user to obtain and analyze: the characteristic curve, modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). The results have shown that the developed software and phantom set allow quality control of digital dental radiology systems in a very objective and quantitative way, facilitating comparative analysis of competing commercial systems. Keywords: Digital dental radiology, quality assurance in radiodiagnostic, characteristic curve, detective quantum efficiency, modulation transfer function, noise power spectrum, noise equivalent quanta. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
14

Elaboração de um guia de referência com imagens radiográficas para aplicação em exames extraorais odontológicos / Elaboration of a reference guide with radiograpich images for application in dental extraoral exams

Mickus, Joice 27 October 2017 (has links)
Os exames radiológicos são importantes recursos no auxílio da elaboração um diagnóstico odontológico preciso. Contudo, só devem ser realizados quando houver uma real indicação clínica, visto que os efeitos das radiações ionizantes no organismo humano são cumulativos. Falhas na execução de procedimentos radiológicos resultam em imagens com qualidade diagnóstica duvidosa, sendo necessária, muitas vezes, a repetição de exames. Desta forma, métodos para minimizar a rejeição imagens radiológicas devem ser observados. A fim de colaborar para a diminuição dos erros de posicionamentos e consequente rejeição de exames de imagem na área da odontologia, este estudo teve por objetivo a criação de um guia de referência para aplicação em exames extraorais odontológicos. Para a elaboração e estruturação deste guia, foi realizado um estudo com o intuito de identificar os motivos de rejeição de radiografias panorâmicas em um serviço de radiologia odontológica digital. O estudo foi retrospectivo e por meio de uma busca no software de aquisição de imagens, foram selecionadas 2306 radiografias panorâmicas digitais, correspondentes a 10% do total de exames realizados entre os anos de 2013 a 2015. A partir da amostra, foram identificados os exames rejeitados e as causas da rejeição. Ainda para colaborar com o desenvolvimento do guia de referência, foi aplicado um questionário aos profissionais técnicos/tecnólogos atuantes no setor de radiologia onde a pesquisa foi realizada. O questionário contou com nove perguntas relacionadas à rotina de trabalho do setor. Com os resultados obtidos na pesquisa foi possível a elaboração do guia de referência com imagens radiográficas para aplicação em exames odontológicos. / The radiological exams are important resources in aid of drafting a dental diagnosis. However, should only be performed when there is a real clinical indication, since the effects of ionizing radiation on the human body are cumulative. Flaws in the implementation of radiological procedures result in doubtful quality diagnostic images, being necessary, many times, the repetition of exams. In this way, methods to minimize radiological images rejection must be observed. In order to contribute to the reduction of errors of positioning and consequent rejection of imaging examinations in the area of dentistry, this study had as its objective the creation of a reference guide for application in dental extraoral examinations. For the preparation and structuring of this guide, a study was conducted with the aim of identifying the reasons for the rejection of panoramic radiographs in a digital dental radiology service. The study was retrospective and by means of a search in the software of image acquisition, were selected 2306 digital panoramic radiographs, corresponding to 10% of the total number of examinations performed between the years of 2013 and 2015. From the sample, were identified the rejected exams and the causes of rejection. To collaborate with the development of the reference guide, a questionnaire was applied at technical professionals working in the radiology sector where the research was conducted. The questionnaire was attended by nine questions related to routine work in the sector. With the results obtained in the study it was possible to do the preparation of the guide of reference with radiographic images for application in dental examinations.
15

Avaliação da dose em pacientes pediátricos submetidos a exame de tomografia computadorizada

Porto, Lorena Elaine 11 December 2014 (has links)
CAPES / A dosimetria em tomografia computadorizada (TC) envolve desde a determinação de grandezas dosimétricas específicas de TC até a estimativa de dose absorvida e dose efetiva. Entretanto, deve-se considerar que por envolver radiação ionizante no seu processo, este procedimento apresenta riscos inerentes e sua utilização deve ponderar o custo e o benefício propiciado pelo procedimento. A proteção de pacientes submetidos a exames radiológicos, de uma maneira geral, é determinada pelos princípios da “justificação” e “otimização”. Desta forma, torna-se importante o conhecimento dos níveis de radiação nas exposições durante um procedimento tomográfico. Estes níveis foram observados através da estimativa das grandezas específicas para tomografia computadorizada, tais como o Índice de kerma no ar (C100,ar), o Índice de kerma ponderada (Cw) e o produto kerma comprimento (PKL,CT), e em estimados os níveis de dose efetiva e risco para o estudo tomográfico computadorizado de crânio, tórax e abdômen realizado com múltipla varredura. Os valores obtidos foram comparados com os obtidos por simulação computacional por Monte Carlo. Eles foram utilizados, neste estudo, no cálculo da Dose Efetiva e risco e para comparação com o nível de referência de dose estabelecido pela Comunidade Européia. Utilizando-se o programa de simulação computacional Dosecal X_CT e o protocolo ICRP 103, foram determinadas as grandezas de radioproteção relevantes para o estudo que são os valores de dose efetiva referente ao procedimento. O nível do Produto kerma comprimento (PKL,CT), utilizando-se o C100,ar previamente estabelecido, foi também obtido e comparado com o nível de referência de dose estabelecido pela comunidade europeia. Os valores encontrados até agora estão dentro dos limites dos Níveis de Referência. / The computed tomography (CT) dosimetry involves measurements of specific quantities of CT, which are part of CT quality control procedures, as well as calculation of absorbed and effective doses to a patient submitted to CT examinations. Since CT uses ionizing radiation, it should be considered that a precise balance between risks and benefits must be achieved in order to justify the adoption of such technique. Radiation protection of patients undergoing radiological exams is established based on the justification and optimization principles. Nowadays, it is important to know the dose radiation levels to which a patient is exposed during a tomographic procedure. Those are given by the estimation of specific dosimetric quantities called the computed tomography kerma index in air, C100,air, the weighted computed tomography kerma index Cw, kerma length product, PKL,CT and then the levels of effective dose and risk to the computerized CT scan study of skull, thorax and abdomen with a multiple scanning. The values obtained were compared with those obtained by computer simulation using Monte Carlo method. The protection quantities organ absorbed dose, effective dose and risk for comparison with the reference dose level established by the European Community. Using computational simulation program of the Dosecal X_CT and the ICRP 103 Protocol, were certain quantities of radiation protection relevant to study which are the values of effective dose for the procedure. The dose length product PKL,CT level was calculated from the C100,air and compared to the reference dose level established by the European Community. The values found so far are within the limits of the reference levels.
16

Caracterização elementar de filtros de alumínio de equipamentos de raios X odontológicos intrabucais

França, Alana Caroline 19 February 2014 (has links)
A busca pela qualidade radiográfica com a menor dose de radiação absorvida é uma constante na comunidade radiológica. Juntamente com o princípio ALARA (As Low As Reasonably Achievable), os filtros de alumínio são peças fundamentais para barrar os fótons de baixa energia que não contribuem para a imagem e depositam dose de radiação para o paciente. De acordo com a Portaria n°453, a Agência Nacional de Vigilância Sanitária decretou que todos os equipamentos de raios X odontológicos intrabucais devem possuir a filtração adicional. Nesse sentido, os filtros são peças fundamentais para a proteção radiológica do paciente. Este estudo tem por objetivo caracterizar a composição elementar dos filtros de raios X de equipamentos de raios X odontológicos intrabucais. O estudo também relaciona a composição elementar com a qualidade das imagens radiográficas. A análise dos filtros foi realizada por meio do método de Espectroscopia de Fluorescência de raios X por Energia Dispersiva (EDXRF). Foram analisados, qualitativa e quantitativamente, dez filtros de alumínio. Para avaliar a qualidade das imagens, foram realizadas 30 radiografias periapicais dos dentes molares com 0,3 s de tempo de exposição (dez radiografias) e incisivos com 0,2 s e 0,3 s (vinte radiografias) com os diferentes filtros em um equipamento com os parâmetros de 66 kV e 6,5 mA. Os filtros e as radiografias foram identificadas, para que fosse possível distinguir a que filtro cada radiografia pertencia no momento das avaliações. Todas as radiografias foram feitas sob as mesmas condições. As radiografias foram submetidas à análise das densidades óticas por um densitômetro e posteriormente, enviadas a cirurgiões dentistas radiologistas que fizeram a análise subjetiva. Foram selecionadas três regiões para análise do densitômetro (diferenciadas entre dentes molares e incisivos) e uma região para análise subjetiva (diferentes regiões para dentes molares e incisivos). Os dados obtidos foram correlacionados com a avaliação dos efeitos da composição elementar dos filtros na qualidade das imagens radiográficas. Os elementos encontrados na análise dos filtros foram: Al, S, Cl, Ti, Mn, Fe, Cu, Zn e Zr. Os filtros apresentaram maiores concentrações de alumínio, com mais de 96% sendo os outros elementos contaminantes ou elementos que foram adicionados para melhorar a estabilidade mecânica do filtro. As densidades óticas das radiografias seguiram um padrão nas regiões analisadas, exceto as regiões enegrecidas do filme. A análise subjetiva revelou que muitas das radiografias realizadas poderiam ser aceitas para diagnóstico. Porém, imagens consideradas com baixo contraste obtiveram o mesmo valor de densidade ótica. Os resultados mostraram que a composição elementar dos filtros não modificou a qualidade da imagem. Por conseguinte, os filtros convencionais pesquisados oferecem uma opção aceitável para a produção de imagens de qualidade em radiologia odontológica, apesar das diferenças na composição das ligas. / The quest for radiographic quality with the lowest dose of radiation absorbed is a constant in the radiology community. Along with the ALARA principle (As Low As Reasonably Achievable), the aluminum filters are essential parts to bar the low energy photons do not contribute to the image and cause radiation dose to the patient. According to standard Portaria No. 453, the Agência Nacional de Vigilância Sanitária decreed that all equipment intraoral dental X-rays must have an additional filtration. Acording this, the filters are essential parts to radiological protection of patients. This study aims to characterize the elemental composition of filters used in intraoral X-ray equipment. We also intend to relate them to the quality of the radiographic images. The analysis of the filters was made using the method Energy Dispersive X-ray Fluorescence (EDXRF). Ten aluminum filters were analyzed (qualitatively and quantitatively). To evaluate the quality of images, 30 periapical radiographs of molars to 0.3 s (ten radiographs) and the incisor teeth 0.2 and 0.3 s (twenty radiographs) were performed with different filters. All filters and all radiographs were identified, it was possible to distinguish which folder each radiograph belonged at the time of the evaluations. All radiographs were performed under the same conditions. Radiographs were subjected to analysis of optical density by a densitometer and later, two dentists radiologists realized a subjective analysis. Three regions for analysis of the densitometer (differentiated between molars and incisors) and a region for subjective analysis (for different regions molars and incisors) were selected. The data were correlated with the assessment of the effects of the elemental composition of all filters in the quality of radiographic images. From the results, the elements of the filters in the analysis were: Al, S, Cl, Ti, Mn, Fe, Cu, Zn and Zr. The filters had higher aluminum concentrations (over 96%), other elements were contaminants or components that are added to improve the mechanical stability of the filter. The optical densities of radiographs followed a pattern for the regions analyzed except blackened regions of the film. Subjective analysis revealed that many of the radiographs were accepted for diagnosis. But considered low-contrast images obtained the same value of optical density. Therefore, it is concluded that the elemental composition of filters do not change the image quality. Consequently, conventional filters were evaluated option to produce an acceptable image quality in dental radiology, despite differences in the composition of the alloys.
17

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
18

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
19

Classificação de defeitos de soldagem em imagens radiográficas PDVD de tubulações de petróleo: uma abordagem com ensemble de Extreme Learning Machines / Classification of welding fedects in radiographic images DWDI of pipeline: an approach with ensemble of Extreme Learning Machines

Boaretto, Neury 27 April 2014 (has links)
A inspeção de defeitos de soldagem em imagens radiográficas de tubulações é bastante subjetiva e está sujeita a erros de interpretação por parte do inspetor laudista. Dentro desse contexto, nos últimos anos tem-se visto um grande esforço no desenvolvimento de métodos automáticos e semiautomáticos de detecção de defeitos em juntas soldadas. Este trabalho apresenta um método automatizado para detecção e classificação de defeitos em imagens radiográficas de juntas soldadas de tubulações obtidas pela técnica de exposição radiográfica parede dupla vista dupla (PDVD), obtidas em reais situações de campo e que, geralmente, têm uma qualidade mais baixa do que as imagens usadas em outros estudos. O método proposto identifica na imagem a região do cordão de solda, detecta as descontinuidades e classifica as mesmas em defeitos e não defeitos, destacando na imagem o resultado. São avaliados classificadores a partir de métodos de classificação por redes neurais Multilayer Perceptron (MLP), redes neurais Extreme Learning Machines (ELM) e classificador estatístico Support Vector Machines (SVM). O método proposto para identificação da região de interesse atingiu 100% de precisão na segmentação do cordão de solda. O classificador SVM apresentou um desempenho melhor que os classificadores MLP e ELM em todos os cenários testados. Com a utilização de ensembles de ELMs obteve-se um F-score de 85,7% para o banco de padrões de teste, resultados satisfatórios quando comprados com trabalhos semelhantes. O uso de ensembles de ELMs representa um ganho de apenas 0,5% no F-score em comparação com o melhor resultado de rede treinada individualmente, entretanto, com o uso de faixas de limiares de decisão do ensemble, o uso do método permite mostrar as descontinuidades sobre as quais o ensemble não tem certeza, destacando na imagem estas descontinuidades. A imagem resultate da aplicação do método serve como auxílio ao especialista na elaboração de laudos. / The inspection of radiographic images of welded joints is very subjective and is subject to errors of interpretation by the inspector. In this context, a great effort has been made in the last years to develop automatic and semiautomatic methods for detecting defects in welded joints. This research work presents an automated method for the detection and classification of defects in radiographic images of welded joints of pipes obtained by the double wall double image (DWDI) exposure technique obtained in real field situations and which generally have a lower quality than the images used in other studies. The proposed methos identifies the region of the weld bead, detects the discontinuities and classifies them as defects and non-defects, highlighting in the image the result. Classifiers are evalueted using methods of classification by multilayer perceptron (MLP) neural networks, extreme learning machines (ELM) neural networks, and Support Vector Machines (SVM). The proposed method for identifying the region of interest reached 100% precision in the segmentation od the weld bead. The SVM classifier performed better than the MLP and ELM classifiers in all scenarios tested. Using ELM ensembles, an F_score of 85,7% was obtained for a test patterns database, satisfactoryresults when compared to similar works. The use of ensembles of ELMs represents a gain of only 0,5% in the F-score compared to the best result of the individually trained network, however, with the use of ensemble decision threshold ranges, the presented method allows to show the discontinuities about which the ensemble is not sure, highlighting in the image these discontinuities as a region of uncertainty, leaving to the specialist the final evaluation of these discontinuities. The image resulting from the application of the method serves as an aid to the expert in the elaboration of reports.
20

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.

Page generated in 0.1216 seconds