• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 1
  • Tagged with
  • 43
  • 38
  • 33
  • 29
  • 21
  • 21
  • 21
  • 20
  • 20
  • 18
  • 18
  • 17
  • 12
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

COMPARAÇÃO DE SENSORES ELETROQUÍMICOS PARA DETERMINAÇÃO DE ENXOFRE EM BIODIESEL / COMPARISON OF ELECTROCHEMICAL SENSORS FOR DETERMINATION OF SULPHUR IN BIODIESEL

Costa, Helmara Diniz 06 June 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:46Z (GMT). No. of bitstreams: 1 Dissertacao Helmara.pdf: 1239564 bytes, checksum: f5a4e670235603269ce13bb3db2a2938 (MD5) Previous issue date: 2013-06-06 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Due to the implementation of more restricted environmental regulation laws, the control of pollution agent such as sulfur compounds has provides the development of new analytic methodologies for its quantification on different matrices, including biodiesel fuel. Thus, this work aims to compare three different sensors - film bismuth and mercury film on the surface of a glassy carbon electrode and solid silver amalgam (dental) - for the determination of sulfur in biodiesel, by means of stripping voltammetric cathodic square wave mode (VRC/SW) as supporting electrolyte with a solution of sodium acetate (1,4 mol.Lˉ¹) and acetic acid (0.33 mol.Lˉ¹) in metanol/2-propanol. In general, the mercury film electrode (MFE) has presented the best electrochemical behavior to the definition of peak reduction, being then selected as standard electrode to the measurements. The sulfur quantization on biodiesel samples was performed by adding 70 μL of soybean biodiesel and tallow fatty with TMAH, adding later, aliquots of standard sulfur. The method showed good linearity (0.998), suggesting an average sulfur concentration of 6,870x10ˉ7 (± 6,857x10ˉ⁸) mol.Lˉ¹, within a confidence interval of 95%, to a limit of detection 3,294x10ˉ¹º mol.Lˉ¹ and quantification limit of 1,098x10ˉ9 mol.Lˉ¹. Besides, for the untreated sample, the experimental has provided a LD of 6,54 x 10ˉ9 mol.Lˉ¹. Finally the proposed method has been compared with the results of a collaborative study (ANP 01/2012) of the same sample using the Teste-t de Student, verifying that the proposed method and official methods (EN ISO 20846, EN ISO 20884) are statistically equivalent to a confidence level of 95%, thereby demonstrating the feasibility of the method. / O controle da poluição ambiental tem exigido, cada vez mais, a determinação de enxofre em uma variedade de matrizes. Diferentes métodos analíticos têm sido desenvolvidos para determinação deste analito em biodiesel, empregando várias técnicas, que vão desde a análise cromatográfica aos métodos espectroanalíticos. No presente trabalho são apresentados os resultados da avaliação de diferentes sensores eletroquímicos para determinação de enxofre em Biodiesel, utilizando a técnica voltamétrica de redissolução catódica no modo onda quadrada (VRC/SW) tendo como eletrólito suporte uma solução de acetato de sódio (1,4 mol.Lˉ¹) e ácido acético (0,33 mol.Lˉ¹), em metanol/2-propanol. Foram avaliados três sensores (filme de bismuto e filme de mercúrio na superfície de carbono vítreo, e eletrodo sólido de amálgama de prata dentária) na determinação de enxofre, sendo observado que o eletrodo de filme de mercúrio (EFM) apresentou os melhores resultados relacionados ao comportamento eletroquímico na definição do pico de redução. Portanto, o EFM foi o sensor escolhido para aplicação na amostra de biodiesel. A determinação do analito em Biodiesel foi realizada adicionando-se 70 μL de Biodiesel de Soja e Sebo (01/2012, interlaboratorial) tratado com TMAH, adicionando, posteriormente, alíquotas de padrão de enxofre. O método apresentou uma boa linearidade (0,998), determinando-se assim uma concentração média de enxofre de 3,687 x 10ˉ7± 6,857 x 10ˉ⁸ mol.Lˉ¹, a um intervalo de confiança de 95%, para um limite de detecção de 3,294 x 10-10 mol.Lˉ¹ e limite de quantificação de 1,098 x 10ˉ9 mol.Lˉ¹, o que demonstra uma boa sensibilidade da técnica. Além disso, avaliou-se o estudo sem tratamento da amostra, na qual obteve-se LD de 6,54 x 10ˉ9 mol.L-1. O presente método foi comparado com os resultados de um estudo interlaboratorial (ANP 01/2012) da mesma amostra, utilizando o Teste-t de Student, verificando que o método proposto e os métodos oficiais (EN ISO 20846; EN ISO 20884) são estatisticamente equivalentes a um nível de confiança de 95%, demonstrando assim a viabilidade do método.
32

Quantificação de cobre, cádmio, chumbo e zinco em mel por voltametria de pulso diferencial com eletrodo de diamante dopado com boro

Honório, Gláucio Gualtieri 08 March 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-31T12:15:22Z No. of bitstreams: 1 glauciogualtierihonorio.pdf: 2076153 bytes, checksum: 5da73e6a28cee53b63fa855e4efb6984 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T02:56:41Z (GMT) No. of bitstreams: 1 glauciogualtierihonorio.pdf: 2076153 bytes, checksum: 5da73e6a28cee53b63fa855e4efb6984 (MD5) / Made available in DSpace on 2016-04-24T02:56:41Z (GMT). No. of bitstreams: 1 glauciogualtierihonorio.pdf: 2076153 bytes, checksum: 5da73e6a28cee53b63fa855e4efb6984 (MD5) Previous issue date: 2013-03-08 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Dependendo da sua origem, o mel pode ter uma mistura de diferentes componentes, principalmente carboidratos, que conferem sabor adocicado ao produto. A concentração mineral é baixa, e depende do ambiente onde o mel é produzido, sendo afetada pela composição do solo, pela geologia e pelas condições geográficas locais. Por ser resultado de um processo de bioacumulação, o mel pode ser utilizado para obter informações a respeito do ambiente em que as abelhas produtoras vivem. O presente trabalho desenvolveu uma metodologia para extração e quantificação de Cu, Pb, Cd e Zn em mel com eletrodo de diamante dopado com boro, por voltametria de pulso diferencial. A metodologia foi otimizada por meio de planejamento de experimentos, com obtenção de modelos de previsão, após um estudo detalhado a cerca da ativação da superfície do eletrodo. O uso de ferramentas estatísticas, como Análise de Componentes Principais, Análise de Variância e superfícies de resposta auxiliaram na obtenção de condições ótimas de análise para os metais com o eletrodo proposto. Para análise de Cu, Pb e Cd utilizou-se o potencial de deposição de -0,95 V vs Ag|AgCl por 240 segundos, em ácido clorídrico 0,1 molL-1. A análise de Zn foi realizada em tampão acetato 0,5 molL-1 com um potencial de deposição de -1,5 V vs Ag|AgCl por 240 segundos. Por se tratar de uma matriz heterogênea e rica em matéria orgânica, um tratamento de digestão da amostra foi necessário. A mineralização do mel em chapa de aquecimento foi o procedimento mais adequado para tratamento da amostra. O método otimizado apresentou seletividade, boa sensibilidade, precisão, exatidão e robustez. A concentração dos analitos encontrados variaram entre 0,242 e 1,378 mgL-1 para o Cu; 0,129 e 0,918 mgL-1 para o Pb e 0,819 e 2,492 mgL-1 para o Zn. O Cd não foi detectado em nenhuma das amostras. As medidas obtidas foram comparadas com eletrodo de carbono vítreo modificado com filme de mercúrio e espectrometria de absorção atômica com forno de grafite, e os resultados encontrados não diferiram estatisticamente, sendo analisados por Análise de Variância. / Depending on the origin, honey can be a mixture of different components, mainly carbohydrates, which give a sweet taste to the product. The mineral concentration is low and depends on the environment where the honey is produced, being affected by soil composition, geology and by the respective geographical locations. Being the result of a process of bioaccumulation, honey can be used to collect information about of environment in which bees live. This study developed a methodology for the extraction and quantification of Cu, Pb, Cd and Zn in honey with boron-doped diamond electrode, by differential pulse voltammetry. The methodology was optimized through design of experiments, obtaining prediction models, after a detailed study concerning the activation of the electrode surface. The use of statistical tools such as Principal Components Analysis, Analysis of variance and response surfaces assisted in obtaining optimum conditions for the analysis of metals with such electrode. For analysis of Cu, Pb and Cd was used the deposition potential of -0.95 V vs Ag|AgCl for 240 seconds, hydrochloric acid 0.1 molL-1. Zn analysis was performed in acetate buffer 0.5 mol L-1 with a deposition potential of -1.5 V vs Ag|AgCl for 240 seconds. Because it is a heterogeneous matrix, rich in organic matter, treatment of digestion of the sample was necessary. The mineralization of honey on heating plate was the most appropriate for treatment of the sample. The optimized method showed selectivity, good sensitivity, precision, accuracy and robustness. The concentration of analytes ranged between 0.242 and 1.378 mgL-1 for Cu, 0.129 and 0.918 mgL-1 for Pb and 0.819 and 2.492 mgL-1 for Zn. The Cd was not detected in any sample. The measurements obtained were compared with glassy carbon electrode modified with mercury film and atomic absorption spectrometry with graphite furnace, and the results did not differ statistically, by Analysis of variance.
33

Determinação sequencial de cromo, tálio, cádmio,chumbo, cobre e antimônio em concentrado polieletrolítico para hemodiálise por voltametria de redissolução através de um gradiente de pH / Sequential determination of chromium, thallium, cadmium, lead, copper and antimony in salinec hemodialysis concentrates by stripping voltammetry using electrolyte pH gradient

Schneider, Alexandre Batista 05 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The sequential voltammetric determination of chromium, thallium, cadmium, lead, copper and antimony, present as contaminants in dialysate concentrates (CPHD), is presented herein. These concentrates contain a very high chloride concentration (ca. 3.8 mol L-1), which makes difficult the direct analysis, without pretreatment, by many analytical techniques, like atomic absorption spectrometry and chromatography. The experimental conditions were varied in order to improve the peak resolution, selectively and sensitivity. The method is based on the gradual decrease on the pH of the solution present in the voltammetric cell, so that, the sequential determination of the analytes was possible. At pH 6 6.2, Cr determination was carried out with DTPA by catalytic adsorptive stripping voltammetry (CAdSV). Afterwards, the pH was adjusted at 4.8 ± 0.2 to determine thallium by anodic stripping voltammetry (ASV). At this pH, DTPA is non interfering specie for Tl-determination and, additionally, it masks the main interfering species for thallium (lead and cadmium). Cadmium, lead and copper were assayed by ASV after setting the pH to 1.5 ± 0.5. Under these conditions, DTPA releases these three metallic species from the previously built complexes, so that they behave as free species to react on the HMDE-surface. By setting with HCl the pH to values around zero antimony was assayed by ASV. At this acidity and in presence of high chloride concentrations antimony can be assayed with high sensitivity. The method was used for analysis of commercial samples of CPHDs and the found concentration varied from < LD until 140 Ug L-1. / A Determinação sequencial de cromo, tálio, cádmio, chumbo e cobre e antimônio em concentrado polieletrolítico para hemodiálise (CPHD) é descrita. Estes concentrados contêm uma concentração extremamente alta de íons cloreto (cerca de 3,8 mol L-1), o que torna difícil a análise direta por muitas técnicas analíticas. As condições experimentais foram variadas a fim de aumentar a resolução de pico, seletividade e sensibilidade. O método é baseado no decréscimo gradual do pH da solução presente na célula voltamétrica, o que possibilitou a determinação sequencial dos analitos. Em pH 6 6,2, a determinação de Cr foi realizada com DTPA por voltametria catalítico-adsortiva de redissolução (CAdSV). Em seguida, o pH foi ajustado para 4,8 ± 0,2 para determinar Tl por voltametria de redissolução anódica (ASV). Neste pH, DTPA não é uma espécie interferente na determinação de Tl e, adicionalmente, ele mascara as principais espécies interferentes para tálio (chumbo e cádmio). Cádmio, chumbo e cobre foram determinados por ASV após ajuste do pH a 1,5 ± 0,5. Sob estas condições, estas três espécies são liberadas em solução a partir dos complexos com DTPA previamente formados, de modo que elas se comportam como espécies livres para reagir na superfície do HMDE. Diminuindo-se o pH da solução para < 0 com HCl, foi determinado antimônio por ASV. Nesta acidez e na presença de uma alta concentração de cloretos, Sb pode ser medido com uma alta sensibilidade. O método foi utilizado para a análise de amostras de CPHD comerciais e as concentrações encontradas dos analitos variaram de < LD até 140 Ug L-1.
34

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica / Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Ribeiro, Luiz Fernando 29 August 2014 (has links)
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de &#181;g L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo, bem como o tempo de deposição no potenciostato. Os limites de detecção e quantificação foram, respectivamente, de 1,3 e 4,3 &#181;g L-1 para o Cu(II), 1,4 e 4,6 &#181;g L-1 para o Pb(II), 0,6 e 1,8 &#181;g L-1 para o Cd(II) e 4,2 e 14 &#181;g L-1 para o Zn(II). Esses limites de detecção e quantificação foram obtidos quando o método funcionou com volume de amostra de 1000 &#181;L, vazão de 10 &#181;L s-1 (durante a etapa de deposição), e utilizando 3 reversões de fluxo (volume de reversão = 950 &#181;L), totalizando um tempo de deposição de 315 segundos. O potenciostato, trabalhando sincronicamente com o sistema SIA operou com potencial de condicionamento de -0,1 V vs. pseudo referência de Ag (100 s), potencial de deposição de -1,0 V para Cu(II), Pb(II) e Cd(II) e de -1,3 V para Zn(II) (315 s), frequência de onda quadrada de 100 Hz, incremento de potencial de 6 mV e altura de pulso de 40 mV. Para determinação de Zn(II) foi necessário depositar Ga0 no eletrodo de trabalho e evitar a formação do intermetálico de Zn0 com Cu0. Estudos de interferentes não apontaram desvios significativos em interferentes aniônicos e catiônicos, mas apresentaram desvios significativos na presença de ácidos húmicos e ácidos fúlvicos. A exatidão do método foi avaliada por estudos de adição e recuperação em amostra de água que resultaram taxas de recuperação próximas de 100%. A exatidão também foi avaliada pelas porcentagens de recuperação das concentrações dos metais da amostra certificada de sedimento CRM-701 submetido ao processo de extração sequencial BCR®. As concentrações obtidas foram testadas pelo teste t de Student, mostrando que os desvios dos valores obtidos em relação aos valores certificados não sugerem a existência de diferenças estatísitcamente significativas. / This dissertation describes the development of a methodology for determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA). Screen printed thin mercury film sensors were used as working electrode in a flow cell. The determinations were made by standard addition, with the SIA system performing the inline dilution of the reference standard solution and forming a segment inside the holding coil containing zones of sample, standard and dilution solutions. The concentration of the standard prepared in this segment generated a current signal undistinguishable from the signal generated by a standard solution of the same concentration prepared manually in a volumetric flask. The limits of quantification and detection were at the level of &#181;g L-1, comparable to those of atomic spectrometry techniques with optic detection, whose instrumental and maintenance costs are significantly higher. With the proposed system the limits of quantification and detection can be increased or lowered by simple change of parameters such as flow rate and number of flow reversals, as well as the deposition time at the potenciostat. The limits of detection and quantification were, respectively, 1.3 and 4.3 &#181;g L-1 for Cu(II), 1.4 and 4.6 &#181;g L-1 for Pb(II), 0.6 and 1.8 &#181;g L-1 for Cd(II) and 4.2 and 14 &#181;g L-1 for Zn(II). These limits of detection and quantification were obtained for a sample volume of 1000 &#181;L, flow rate of 10 &#181;L s-1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion = 950 &#181;L) totalizing a deposition time of 315 seconds. The potentiostat worked synchronically with the SIA system performing a conditioning potential of -0,1 V vs pseudo reference of Ag (100 s), deposition potential of -1,0 V for Cu(II), Pb(II) and Cd(II) or -1,3 V for Zn(II) (315 s), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For determination of Zn(II), deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. Studies of interference did not point significant deviation for anionic and ionic potentially interfering substances, but exhibited significant deviations in the presence of humic and fulvic acids. The accuracy of the method was assessed by spike and recovery experiments in a water sample that resulted recovery rates near of 100%. The accuracy was also assessed by percentages of recovery of concentrations of metals in the certified sediment sample CRM-701 undergoing the sequential extraction procedure of BCR®. The concentrations obtained were tested by test t of Student, showing that the deviations of the obtained values don´t suggest the occurrence of statistically significant differences
35

Estudo dos metais traço (zinco, cádmio e chumbo) em duas regiões do complexo estuarino-lagunar de Cananéia-Iguape(SP) sob diferentes pressões antrópicas / Trace metals study (zinc, cadmin and lead) in two regions of Cananéia-Iguape (SP) estuarine-lagoon system submitted to different anthropic pressures

Maluf, João Carlos Cattini 16 October 2009 (has links)
Os setores sul e norte do complexo estuarino lagunar de Cananéia-Iguape, sujeitos a diferentes pressões antrópicas, foram estudados quanto às características hidrológicas e hidroquímicas das águas de superfície e fundo, com ênfase às concentrações de zinco, cádmio e chumbo dissolvidos. A amostragem contou com coletas espaciais e temporais, em dois períodos sazonais (outono e primavera) de 2007. Os metais estudados foram: o zinco, devido ação tóxica ou como micronutriente, dependendo de sua concentração, o cádmio e o chumbo, considerados sem função biológica positiva conhecida e com alto grau de toxicidade para a biota. A metodologia utilizada na determinação da concentração dos metais traço foi a voltametria por redissolução anódica. No setor sul, a variação da salinidade foi característica de um sistema estuarino não impactado. Os teores dos metais traço encontrados sofreram variação entre 0,040 e 0,509 ?g L-1 para o zinco, 0,001 e 0,024 ?g L-1 para o cádmio e entre 0, 030 e 0,175 ?g L-1 para o chumbo. No setor norte, a variação salinidade mostrou forte influência de água doce. O zinco sofreu variação entre 0,097 e 0,257 ?g L-1, o cádmio entre 0,004 e 0,024 ?g L-1 e o chumbo 0,033 e 0,259 ?g L-1. Nos dois setores, as concentrações dos metais traço estiveram sempre abaixo dos limites propostos pela legislação ambiental brasileira (CONAMA) e norte-americana (EPAUSA). O presente estudo mostrou um maior do impacto antrópico na região norte, com potencial de exportação para o setor sul e plataforma. As maiores concentrações dos metais traço estudados ocorreram nas águas de fundo, mais próximas à interface com o sedimento. O setor sul, sujeito a uma variação da salinidade mais definida, mostrou maior potencial para a remobilização dos metais traço para a coluna de água com o movimento de maré. O estudo dos ciclos biogeoquímicos dos metais traço deve ser incentivado no monitoramento ambiental da região. / The south and north regions of Cananeia-Iguape estuarine-lagoon system submitted to different anthropic pressures were studied to evaluate their hydrological and hydrochemical characteristics mainly considering the concentrations of dissolved zinc, cadmium and lead. The sampling included spatial and temporal samples obtained in two seasons (autumn and spring) of 2007. The metals studied were zinc as a toxic agent and micronutrient depending on the concentration and cadmium and lead with no biological positive relevance and high toxicity to the biota. The methodology used in the trace metals determination was anodic stripping voltammetry. In the south portion the salinity variation was characteristic of non-impacted estuaries. The zinc concentrations ranged from 0,040 to 0,509 ?g L-1. The cadmium ranged from 0,001 to 0,024 ?g L-1. The lead content ranged from 0,030 to 0,175 ?g L-1. In the north portion, the salinity variation showed high influence of fresh water. The zinc concentrations ranged from 0,097 to 0,257 ?g L-1. The cadmium concentrations ranged from 0,004 to 0,024 ?g L-1. The lead values ranged from 0,033 to 0,259 ?g L-1. The concentration of trace metals on both portions were below the limits proposed by the Brazilian environmental law (CONAMA) and North American (EPAUSA) legislation. The present study revealed higher anthropic impact in the north region with exporting potential to the south and to the continental shelf. Higher trace metals concentrations were observed in the bottom waters near to the sediment interface. The south region, submitted to most defined tide movements, showed an important potential for trace metals remobilization to the water column. The trace metals biogeochemistry cycles study should be enhanced for better environmental monitoring.
36

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica / Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Luiz Fernando Ribeiro 29 August 2014 (has links)
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de &#181;g L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo, bem como o tempo de deposição no potenciostato. Os limites de detecção e quantificação foram, respectivamente, de 1,3 e 4,3 &#181;g L-1 para o Cu(II), 1,4 e 4,6 &#181;g L-1 para o Pb(II), 0,6 e 1,8 &#181;g L-1 para o Cd(II) e 4,2 e 14 &#181;g L-1 para o Zn(II). Esses limites de detecção e quantificação foram obtidos quando o método funcionou com volume de amostra de 1000 &#181;L, vazão de 10 &#181;L s-1 (durante a etapa de deposição), e utilizando 3 reversões de fluxo (volume de reversão = 950 &#181;L), totalizando um tempo de deposição de 315 segundos. O potenciostato, trabalhando sincronicamente com o sistema SIA operou com potencial de condicionamento de -0,1 V vs. pseudo referência de Ag (100 s), potencial de deposição de -1,0 V para Cu(II), Pb(II) e Cd(II) e de -1,3 V para Zn(II) (315 s), frequência de onda quadrada de 100 Hz, incremento de potencial de 6 mV e altura de pulso de 40 mV. Para determinação de Zn(II) foi necessário depositar Ga0 no eletrodo de trabalho e evitar a formação do intermetálico de Zn0 com Cu0. Estudos de interferentes não apontaram desvios significativos em interferentes aniônicos e catiônicos, mas apresentaram desvios significativos na presença de ácidos húmicos e ácidos fúlvicos. A exatidão do método foi avaliada por estudos de adição e recuperação em amostra de água que resultaram taxas de recuperação próximas de 100%. A exatidão também foi avaliada pelas porcentagens de recuperação das concentrações dos metais da amostra certificada de sedimento CRM-701 submetido ao processo de extração sequencial BCR®. As concentrações obtidas foram testadas pelo teste t de Student, mostrando que os desvios dos valores obtidos em relação aos valores certificados não sugerem a existência de diferenças estatísitcamente significativas. / This dissertation describes the development of a methodology for determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA). Screen printed thin mercury film sensors were used as working electrode in a flow cell. The determinations were made by standard addition, with the SIA system performing the inline dilution of the reference standard solution and forming a segment inside the holding coil containing zones of sample, standard and dilution solutions. The concentration of the standard prepared in this segment generated a current signal undistinguishable from the signal generated by a standard solution of the same concentration prepared manually in a volumetric flask. The limits of quantification and detection were at the level of &#181;g L-1, comparable to those of atomic spectrometry techniques with optic detection, whose instrumental and maintenance costs are significantly higher. With the proposed system the limits of quantification and detection can be increased or lowered by simple change of parameters such as flow rate and number of flow reversals, as well as the deposition time at the potenciostat. The limits of detection and quantification were, respectively, 1.3 and 4.3 &#181;g L-1 for Cu(II), 1.4 and 4.6 &#181;g L-1 for Pb(II), 0.6 and 1.8 &#181;g L-1 for Cd(II) and 4.2 and 14 &#181;g L-1 for Zn(II). These limits of detection and quantification were obtained for a sample volume of 1000 &#181;L, flow rate of 10 &#181;L s-1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion = 950 &#181;L) totalizing a deposition time of 315 seconds. The potentiostat worked synchronically with the SIA system performing a conditioning potential of -0,1 V vs pseudo reference of Ag (100 s), deposition potential of -1,0 V for Cu(II), Pb(II) and Cd(II) or -1,3 V for Zn(II) (315 s), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For determination of Zn(II), deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. Studies of interference did not point significant deviation for anionic and ionic potentially interfering substances, but exhibited significant deviations in the presence of humic and fulvic acids. The accuracy of the method was assessed by spike and recovery experiments in a water sample that resulted recovery rates near of 100%. The accuracy was also assessed by percentages of recovery of concentrations of metals in the certified sediment sample CRM-701 undergoing the sequential extraction procedure of BCR®. The concentrations obtained were tested by test t of Student, showing that the deviations of the obtained values don´t suggest the occurrence of statistically significant differences
37

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Antunes Junior, Osmar 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 &#181;L) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 &#181;L) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.
38

Estudo dos metais traço (zinco, cádmio e chumbo) em duas regiões do complexo estuarino-lagunar de Cananéia-Iguape(SP) sob diferentes pressões antrópicas / Trace metals study (zinc, cadmin and lead) in two regions of Cananéia-Iguape (SP) estuarine-lagoon system submitted to different anthropic pressures

João Carlos Cattini Maluf 16 October 2009 (has links)
Os setores sul e norte do complexo estuarino lagunar de Cananéia-Iguape, sujeitos a diferentes pressões antrópicas, foram estudados quanto às características hidrológicas e hidroquímicas das águas de superfície e fundo, com ênfase às concentrações de zinco, cádmio e chumbo dissolvidos. A amostragem contou com coletas espaciais e temporais, em dois períodos sazonais (outono e primavera) de 2007. Os metais estudados foram: o zinco, devido ação tóxica ou como micronutriente, dependendo de sua concentração, o cádmio e o chumbo, considerados sem função biológica positiva conhecida e com alto grau de toxicidade para a biota. A metodologia utilizada na determinação da concentração dos metais traço foi a voltametria por redissolução anódica. No setor sul, a variação da salinidade foi característica de um sistema estuarino não impactado. Os teores dos metais traço encontrados sofreram variação entre 0,040 e 0,509 ?g L-1 para o zinco, 0,001 e 0,024 ?g L-1 para o cádmio e entre 0, 030 e 0,175 ?g L-1 para o chumbo. No setor norte, a variação salinidade mostrou forte influência de água doce. O zinco sofreu variação entre 0,097 e 0,257 ?g L-1, o cádmio entre 0,004 e 0,024 ?g L-1 e o chumbo 0,033 e 0,259 ?g L-1. Nos dois setores, as concentrações dos metais traço estiveram sempre abaixo dos limites propostos pela legislação ambiental brasileira (CONAMA) e norte-americana (EPAUSA). O presente estudo mostrou um maior do impacto antrópico na região norte, com potencial de exportação para o setor sul e plataforma. As maiores concentrações dos metais traço estudados ocorreram nas águas de fundo, mais próximas à interface com o sedimento. O setor sul, sujeito a uma variação da salinidade mais definida, mostrou maior potencial para a remobilização dos metais traço para a coluna de água com o movimento de maré. O estudo dos ciclos biogeoquímicos dos metais traço deve ser incentivado no monitoramento ambiental da região. / The south and north regions of Cananeia-Iguape estuarine-lagoon system submitted to different anthropic pressures were studied to evaluate their hydrological and hydrochemical characteristics mainly considering the concentrations of dissolved zinc, cadmium and lead. The sampling included spatial and temporal samples obtained in two seasons (autumn and spring) of 2007. The metals studied were zinc as a toxic agent and micronutrient depending on the concentration and cadmium and lead with no biological positive relevance and high toxicity to the biota. The methodology used in the trace metals determination was anodic stripping voltammetry. In the south portion the salinity variation was characteristic of non-impacted estuaries. The zinc concentrations ranged from 0,040 to 0,509 ?g L-1. The cadmium ranged from 0,001 to 0,024 ?g L-1. The lead content ranged from 0,030 to 0,175 ?g L-1. In the north portion, the salinity variation showed high influence of fresh water. The zinc concentrations ranged from 0,097 to 0,257 ?g L-1. The cadmium concentrations ranged from 0,004 to 0,024 ?g L-1. The lead values ranged from 0,033 to 0,259 ?g L-1. The concentration of trace metals on both portions were below the limits proposed by the Brazilian environmental law (CONAMA) and North American (EPAUSA) legislation. The present study revealed higher anthropic impact in the north region with exporting potential to the south and to the continental shelf. Higher trace metals concentrations were observed in the bottom waters near to the sediment interface. The south region, submitted to most defined tide movements, showed an important potential for trace metals remobilization to the water column. The trace metals biogeochemistry cycles study should be enhanced for better environmental monitoring.
39

Determinação voltamétrica de triclocarban e carbendazim em produtos de higiene pessoal e água potável

Lúcio, Maria Mônica Lacerda Martins 26 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-11T12:53:38Z No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) / Made available in DSpace on 2016-05-11T12:53:38Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) Previous issue date: 2015-08-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Triclocarban (TCC) is a bactericide and fungicide widely used in personal care products, while carbendazim (MBC) is a fungicide widely used in cereal crops and a variety of fruits and vegetables, both are considered environmental contaminants. In this paper, propose the study of oxidation and determination of TCC using glassy carbon electrode (ECV) and the use of a carbon paste electrode modified with carbon nanotubes functionalized multi walled (EPC-NTCPMF) to determine MBC. Electrochemical detection of TCC and MBC was studied using different voltammetric techniques on a wide range of pH and the determination was performed on samples of soaps, only the TCC and drinking water at low concentrations, for both contaminants. For TCC, various oxidation processes were observed, however the peak P1 had greater sensitivity and selectivity in acetate buffer, pH 5.4 and was therefore used for the development of voltammetric methods, direct VOQ and adsorptive stripping voltammetry. For adsorptive stripping voltammetry, the linear response range was from 1.8 to 21 × 10-9 mol L-1 with a detection limit (LD) of 3.2 × 10-10 mol L-1, 1,000 times smaller than the LD obtained by direct VOQ. The method of adsorptive stripping voltammetry showed satisfactory levels of repeatability, 4.1% and reproducibility, 5.4% and was applied to determine TCC in soaps samples and an average recovery of 95.3% and drinking water with an average recovery apparent 95.4%. The MBC peaked main oxidation, almost reversible; the better sensitivity was achieved in H2SO4, pH 1.0 on the EPC-NTCPMF using VOQ. The linear response range is between 3 and 150 × 10-10 mol L-1 to LD 1.1 × 10-11 mol L-1. The method developed showed acceptable levels of repeatability, 4.6% and reproducibility, 6.2% and was applied for MBC determination in drinking water samples obtained average apparent recovery of 95.6%. The results obtained in the development of methods for determination of TCC and MBC showed excellent applicability for the studied samples, in addition to having advantages such as low cost instrumentation, analytical fast response, high sensitivity and selectivity. / Triclocarban (TCC) é um bactericida e fungicida amplamente utilizado em produtos de higiene pessoal, enquanto que o carbendazim (MBC) é um fungicida muito utilizado em culturas de cereais e numa grande variedade de frutas e vegetais, e ambos são considerados contaminantes ambientais. Nesse trabalho, propõe-se o estudo da oxidação e determinação do TCC utilizando eletrodo de carbono vítreo (ECV) e o uso de um eletrodo de pasta de carbono modificado com nanotubos de carbono de múltiplas paredes funcionalizado (EPC-NTCPMF) para determinação de MBC. A detecção eletroquímica de TCC e MBC foi estudada utilizando diferentes técnicas voltamétricas sobre uma ampla faixa de pH e a determinação foi realizada em amostras de sabonetes para TCC e em água potável em baixas concentrações para os dois contaminantes. Para TCC, foram observados seis processos de oxidação, entretanto, o processo correspondente ao pico P1 apresentou maior sensibilidade e seletividade em tampão acetato pH 5,4, portanto, foi utilizado para o desenvolvimento das metodologias voltamétricas, VOQ direta e VOQ com redissolução adsortiva. Para a VOQ com redissolução adsortiva, a faixa de resposta linear foi de 1,8 a 21 × 10-9 mol L-1 com limite de detecção (LD) de 3,2 × 10-10 mol L-1, 1.000 vezes menor do que o LD obtido por VOQ direta. O método de redissolução adsortiva apresentou níveis satisfatórios de repetibilidade, 4,1% e reprodutibilidade, 5,4% e foi aplicado para determinação de TCC em amostras de sabonetes, obtendo uma recuperação média de 95,3% e água potável com uma média de recuperação aparente de 95,4%. O MBC apresentou um pico de oxidação principal, quase reversível e a maior sensibilidade foi alcançada em H2SO4, pH 1,0, sobre o EPC-NTCPMF, utilizando VOQ. A faixa de resposta linear está entre 3 e 150 × 10-10 mol L-1 com LD de 1,1 × 10-11 mol L-1. O método desenvolvido apresentou níveis satisfatórios de repetibilidade, 4,6% e reprodutibilidade, 6,2% e foi aplicado para determinação de MBC em amostras de água potável, obtendo-se valor médio de recuperação aparente de 95,6%. Os resultados obtidos no desenvolvimento dos métodos para determinação de TCC e MBC demonstraram excelente aplicabilidade para as amostras estudadas, além de apresentarem vantagens como instrumentação de baixo custo, rápida resposta analítica, elevada sensibilidade e seletividade.
40

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Osmar Antunes Junior 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 &#181;L) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 &#181;L) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.

Page generated in 0.0717 seconds